You are on page 1of 2

Product Data Sheet

STAAD(X).TOWER
Structural modeling, analysis and design solution
for communication towers

STAAD(X).Tower provides comprehensive analysis and design of monopoles, self-supporting and


guyed communication towers through physical modeling and parametric tools.

Comprehensive Analysis and Design Tools handles the insertion and editing of bracing systems in a
smarter way. Through easy parametric changes, the overall
STAAD(X).Tower easily allows engineers to generate
tower geometry including slope changes can be achieved.
self-supporting towers, guyed towers and monopoles using
its parametric setup wizards. And STAAD(X).Tower offers STAAD(X).Tower provides a comprehensive in-built library
bi-directional interoperability with other STAAD(X) products of standard bracing patterns with an extended facility to
like STAAD(X) and STAAD.foundation to provide additional create and store user defined bracing patterns for future
analysis and design of your structure. use. It also allows the user to treat a set of analytical
Engineers now have the flexibility to design physical members as a group. It automatically considers the set of
Handle bracing patterns in a smarter way
members as per TIA-222-F and TIA-222-G codes. The design individual analytical members of the tower legs and brac-
capability includes both trusses as well as frame member ings as single physical members based on certain criteria.
types. For each physical member the user can explicitly
Automatic Calculation of Wind, Ice,
define the design parameters following the desired stan-
and Seismic Loads
dard and can browse the detail design calculation with all
allowable and actual values. Users will enjoy maximum productivity with our impressive
group of features that automatically generates wind, ice,
With STAAD(X).Tower, external components like anten- and seismic loads, following the TIA-222-F and TIA-222-G
nas, appurtenances, and platforms can easily be attached standards. Based on user specified state and county
and can generate wind, ice, seismic loads following the information, it extracts wind speed, ice thickness and
TIA codes along with other standard reference loads. The spectral acceleration values and automatically calculates
robust analysis and design engine (as per TIA-222-F & height dependant gust factors, velocity pressures, effective
TIA-222-G codes) helps to minimize efforts to obtain the projected areas, and distributes the forces on the overall
analysis and design results. structure. STAAD(X).Tower automatically readjusts loads
Construct parametric physical tower model STAAD(X).Tower provides easy drag & drop features for in the event of changes in overall geometry, assigned sec-
inserting non-structural components like dish antennas, tions, and external attachments.
appurtenances, and platform mounts for monopoles. It also
Powerful Results and Diagrams
allows the user to browse and maintain the catalogs for
STAAD(X).Tower provides an exhaustive set of post-pro-
such components. Additionally, users can adjust the mount-
cessing features that includes results and diagrams. It ren-
ing patterns and reorient tilt and azimuth angles for these
ders leg compression curves, deflection, tilts, twists, axial
components as required.
forces, moments, torsion, and stress diagrams along with
Increased Modeling Efficiency with dynamic browsing facility for member forces and member
Standards and Wizards stresses at any point of the cross-section on any member at
Engineers can now model faster than ever using our any location for any analysis load case. It displays tables
physical model generation utilities thorough parametric for member end forces, joint displacements, and support
wizards. This includes automatic and intuitive formation reactions. Customizable and user-friendly report generation
of physical members with appropriate orientations. It also facility is also provided.
Get detailed in-sight of analysis results
SYSTEM REQUIREMENTS STAAD Tower AT-A-GLANCE
Processor:
Intel Pentium or AMD AthlonT Wizard driven parametric physical Enhances overall profitability Customizable, user-friendly
model generation for square and by allowing the user to use and exhaustive Report generation
Operating System:
triangular self-supporting and maintain component catalogs. facility
Windows Vista, XP, and 2000
guyed towers, and monopoles Automatic generation of wind, Create all exhaustive complete
RAM:
Enhances productivity through ice, and seismic load cases for report straight from the soft-
512MB minimum,
1GB recommended faster model generation wizards tower structures and external ware and avoid manual report
Saves time on overall parametric attachments as per TIA-222-F compilation activities.
Available Languages:
English editing of the physical model and TIA-222-G standards Establish dynamic update links
In-built library of standard bracing Saves time and allows investi- and save time in regenerating
Complementary Products:
patterns with facilities to create gation of whatif scenarios. the desired report.
STAAD(X).FEM
user-defined ones Analysis- Linear static analysis Bi-directional interoperability with
Provides smooth automatic and second-order analysis other STAAD(X) family products
ABOUT BENTLEY generation of analytical Post-Processing features includes Avoid duplication of efforts
structure for any user defined in case you need to transfer
Bentley Systems, Incorporated joint displacements, member
is the global leader dedicated physical model the model to other family
forces, stresses, support reactions,
to providing comprehensive Increases productivity by of products.
leg compression, deflection, tilt,
software solutions for sustaining providing a library of reusable Save time in generating a
and twist results in terms of
infrastructure. Architects, engineers, bracing patterns composite structure that
constructors, and owner-operators diagrams and tables
Extensive parametric editing involves both STAAD(X) and
are indispensable in improving our Enables the user to have
facilities to incorporate changes STAAD(X).Tower.
world and our quality of life; the a detailed in sight of the
companys mission is to improve in towers overall shape and
analysis results.
the performance of their projects slope, panel dimensions and
and of the assets they design, build, panel face configurations Helps to plot multiple
and operate. Bentley sustains the post-processing diagrams
Intuitive physical member creation
infrastructure professions by helping for a selective set of
to leverage information technology, with appropriate orientation
physical members for
learning, best practices, and global Easy to use drag & drop features
collaboration and by promoting
complex structures.
for inserting non-structural
careers devoted to this crucial work. components from built-in database Design of physical members
like dish antennas, appurtenances, as per TIA-222-F and TIA-222-G
For more information, visit
www.bentley.com and platforms with facilities to standards
adjust mounting pattern, location, Reduces errors due to
tilt and azimuth angles complex calculations.
BENTLEY OFFICES
Corporate Headquarters
685 Stockton Drive
Exton, PA 19341 USA
1-800-BENTLEY (1-800-236-8539)
Outside the US +1 610-458-5000

Bentley Systems Europe B.V.


Wegalaan 2
2132 JC Hoofddorp
Netherlands
+31 23 556 0560

Bentley Asia
Unit 1402-06, Tower 1,
China Central Place,
No. 81 Jianguo Road, Drag and drop built-in external components Render post-processing diagrams and graphs
Beijing, 100025, China
+86 108 518 5220

2008 Bentley Systems, Incorporated. Bentley, the B Bentley logo, and STAAD are either registered or unregistered trademarks of Bentley Systems,
Incorporated or one of its direct or indirect wholly owned subisdiaries. Other brands and product names are trademarks of their respective owners.
BAA015890-1/0001 11/08

You might also like