Metal Enclosed
Switchgears
Nature is
Our Most
Valuable Partner
MV Air Insulated Metal Enclosed Switchgears
Brief History Of Company; Elimsan
Some of other main products are; MV-HV CTs, VTs, Fuses, and Lighting Fixtures. All of
ourproducts have type test reports from CESI (Italy), KEMA (Holland), IPH (Germany) and ICMET (Romania).
By developing its own technology considering quality importance, Elimsan became one of
transmission and distribution systems. Since last 29 years, more than 100.000 units of these equipments had been
manufactured and distributed over all Turkey and world.They are all under operation satisfactorily since their assembly
Elimsan has a very large land more than 550.000 sqm and 50.000 sqm closed facilities. All of our
equipments are manufactured with CNC controlled workbenches under the ISO 9001 Quality Management
System and ISO 14001 Environmental Management System. Our products are tested in our accredited High Voltage
Laboratories according to ISO 17025 standards.
Since the establishment date, Elimsan always produces advanced technology along the Turkeysdevelopment
process; represents our country successfully, challenges in competitive international market conditions. Its
products are preferred on wide geographical areas from Australia to Estonia, from Far East to South America.
In the year of 2008 Elimsan has signed a partnership agreement with Saudi Cable which is on of the
Elimsan is a creative, innovated and dynamic company. We respect and pay much attention to
communicate and interact with our clients; and meeting each customers needs is our number one priority.
3
MV Air Insulated Metal Enclosed Switchgears
Elimsan TG21-XX designation covers medium voltage cubicles or prefabricated systems with SF6 or vacuum
These switchgears permit carry out all the functions that could be presented, so much in the networks of
electrical energy distribution and transformer centers.
Operations of development, such as to break in no-load of the ring networks or radial networks.
Disconnecting with earthing of the active parts, to effect periodic maintenance.
Protection of power transformers for overloads and short circuits.
Troubleshooting in cables and monitoring the phases conformity before making of cloosed- loops.
STANDARTS
The switchgears have been developed and tested according to the following procedures:
PROTECTION DEGREE
Load Break Switch : IP68
Busbar Compartment : IP3X
Between Compartment : IP3X
Mechanisms : IP3X
Cable Compartment : IP3X
Switchgear in service:
Being in service with the switch closed, to access to the interior of the switchgear, its necessary to accomplish
the following operations:
Open the switch.
Verify the absence of tension in the cables by means of the neon lamps of voltage indicators.
Close the earthing-switch.
Open the door.
To open the door previously earthing switch must be closed. In this position:
The switch can not be closed.
The earthing switch can not be opened.
4
MV Air Insulated Metal Enclosed Switchgears
EXAMPLE 1
To accomplish the measure in cables will can be get, by a wiling action, realising the interlocks using an
This equipment prevents closing of the door and, before closing it have to be removed, remaining the
interlocks in its initial position.
To prevent that someone could operate the switchgear, while are effected the measurements in the cables,
exits a safety device that prevents the introduction of the operating lever.
Service continuity:
The segregations of the various compartments allow to operate when switchboard alive to re-place
components such as fuses, relays, cable terminals, etc.
Safety:
Suitables mechanical and key locks, guarantee the safety of personel, prevent-
ing from any possibility of wrong operations. The metal segregations between the bus-
bar compartment and the instruments compartment, prevents accidental contacts with medium
voltage components. The switchboard is provided with grounding of the whole structure and components.
5
MV Air Insulated Metal Enclosed Switchgears
The busbar insulating supports are integral with the switchgear (switch or disconnector)
conventional crew/spring washer attachment. The connection screw is covered by a stress cap.
The front access is elosed by a bolted plate with a yellow warning plate.
EXAMPLE 2 EXAMPLE 3
Customer Measurement and Distrubution Center
Transformer Protection System
Load Break Switch cubicles and off-load disconnector cubicles: The lower part of the switch and of the
clips.
Transformer protection cubicles: Connection is made at the fuse lower supports.
Circuit Breaker cubicles: connection is made on a support lug mounted on the capacitor dividers.
The reduced depth of the cubicles results in the last phase being within arm reach, and this greatly facilitates
cable installation.
For easier work, a stud enables the operator to hook up the cable end clip during the connection operation.
EARTHING SWITCHES
In generally Elimsan switchboards have two simultaneously operated earthing switches. The station earth
bar is situated on the cubicle top. The station is connected to earth by means of a contact stud on the
forward part of the side partition.
The lower part of cubicles houses standardized for fuses. During fuses changing the operators safety is
ensured by two earthing switches.
6
MV Air Insulated Metal Enclosed Switchgears
Motor protection:
Within the limit of 3 starting per hour, each of a duration
of 10 seconds and with Id/ln < 6 (Id = starting current and
In = motor rated current), use fuses with a rated current
immediately superior to 3 times the motor rated current.
DISCONNECTOR MONITORING
The disconnector control is shown on the mimic
diagram by the position of a rod directly coupled to the
control shaft carrying the contacts without any intermediate
linkage. This provides a fail safe indication of the position
(open or closed) of the switch.
Circuit Breaker Compartment
VOLTAGE MONITORING
Voltage presence or absence is shown by means of
neon indicator lights connected to the capacitor dividers
7
MV Air Insulated Metal Enclosed Switchgears
TYPES DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12
TG21-01 X X
TG21-02 X X X X X X
TG21-02V X X X X X X
TG21-03 X X X X
TG21-04 X X X X
-
TG21-04V X X X X
NECTOR
TG21-05 X X X X X
TG21-05V X X X X X
TG21-07 X X X X X
TG21-11 X X X X
TG21-13 X X X X X
TG21-14 X X X X
TG21-15 X X X
TG21-16 X X X X X
TG21-17 X X
TG21-18 X
TG21-19 X X
TG21-22 X X
TG21-27 X X X X X X X
TG21-27V X X X X X X X
8
MV Air Insulated Metal Enclosed Switchgears
General 12 kV 17.5 kV 24 kV 36 kV 38,5 kV
Rated mainly active load breaking current 400 A 400/630 A 400/630 A 400/630 A 400/630 A
Rated no-load transformer breaking current 10(16) A 10(16) A 10(16) A 10(16) A 10(16) A
0.5 Bar 0.5 Bar 0.5 Bar 0.5 Bar 0.5 Bar
switch 20 C
Rated short-circuit making current (peak) 40/50 kA 40/50/63 kA 40/50/63 kA 40/50/63 kA 40/50/63 kA
9
MV Air Insulated Metal Enclosed Switchgears
10
11
MV Air Insulated Metal Enclosed Switchgears
MV Air Insulated Metal Enclosed Switchgears
12
LEGEND
13
MV Air Insulated Metal Enclosed Switchgears
MV Air Insulated Metal Enclosed Switchgears
CONTACT
EQUIPMENT VOLTAGE POWER
QUANTITY
14