Professional Documents
Culture Documents
Huawei Omc Operation Wcdma PDF
Huawei Omc Operation Wcdma PDF
Internal Open
Product version
Total 220 pages
3.5
Approved by Date
Revision Records
Table of Contents
1 Introduction ............................................................................................................................. 16
1.1 Contents ......................................................................................................................... 16
1.2 Overview of WCDMA Networking .................................................................................... 17
1.3 Introduction ..................................................................................................................... 18
1.4 Rules and Precautions in Equipment Room ..................................................................... 19
2 RNC OM System ...................................................................................................................... 19
2.1 Installing and Starting RNC ............................................................................................. 19
2.2 Tracing Signaling at Standard Interfaces of BSC6800 Single Subscriber ......................... 22
2.2.1 Background .......................................................................................................... 22
2.2.2 Procedure ............................................................................................................. 22
2.3 Tracing Connection Performance of RNC Single Subscriber............................................ 28
2.3.1 Content ................................................................................................................. 28
2.3.2 Procedure ............................................................................................................. 28
2.4 Tracing RNC Cell Performance ....................................................................................... 29
2.4.1 Content ................................................................................................................. 29
2.4.2 Procedure ............................................................................................................. 30
2.5 Tracing RNC Calls .......................................................................................................... 33
2.6 Tracing RNC Protocol Messages at Transport Network Layer ......................................... 35
2.7 Tracing RNC MNCDT...................................................................................................... 37
2.8 Tracing RNC CDT/IFTS .................................................................................................. 40
2.9 RNC MML Command Line .............................................................................................. 44
2.10 Editing and Executing RNC Batch Processing Scripts.................................................... 50
2.10.1 Editing RNC Batch Processing Scripts ................................................................ 50
2.10.2 Executing RNC Batch Processing Scripts............................................................ 53
2.11 Other Optimizations of RNC .......................................................................................... 62
2.11.1 Importing and Exporting CFGMML File................................................................ 62
2.11.2 Extracting CHR Log ............................................................................................ 66
2.11.3 Extracting Traffic Measurement Data Files .......................................................... 66
2.11.4 Tracing IOS ........................................................................................................ 67
3 M2000 OM System ................................................................................................................... 70
3.1 Starting M2000 OM System ............................................................................................ 70
3.1.1 Functions .............................................................................................................. 70
3.1.2 Procedure ............................................................................................................. 70
3.2 View MML command execution results on the M2000 ..................................................... 72
3.3 View Subsequent Packets Generated by an MML command on the M2000 ..................... 72
3.4 Start the configuration management express (CME) on the M2000.................................. 73
3.5 Extract BCP compression package through CME on the M2000. ..................................... 73
3.6 Start the LMT of NEs on the M2000................................................................................. 75
3.7 Starting Simulated Load on NodeB in M2000 .................................................................. 79
3.7.1 Background .......................................................................................................... 79
3.7.2 Procedure ............................................................................................................. 80
3.8 Stopping Simulated Load on NodeB in M2000................................................................. 81
3.9 Querying Starting Simulated Load on NodeB................................................................... 82
3.10 Editing and Executing Scripts for Starting and Stopping Simulated Load on NodeB in
M2000 .................................................................................................................................. 84
3.10.1 Editing Scripts for Starting and Stopping Simulated Load on NodeB in M2000..... 84
3.10.2 Executing Batch Processing Scripts for Starting and Stopping Simulated Load on
NodeB in M2000 ............................................................................................................ 84
List of Tables
Table 2-1 List of tracing on BSC6800 .................................................................................. 33
Table 2-2 Traced messages at transport network layer on BSC6800 ................................... 35
Table 2-3 BSC6800 MML commands used in radio network planning and optimization ....... 45
Table 4-1 A set of MML commands used frequently on NodeB in RNP&O .......................... 118
Table 4-2 Operation commands for electric antenna of BTS3812/3806/3806A ...................151
Table 4-3 Operation commands for electric antenna of BTS 3812E/A, BBU, and DBS........152
Table 9-1 DPCH spreading code, timing offsets, and relative level settings for OCNS signal
...................................................................................................................................184
Table 9-2 Parameter mapping table ...................................................................................199
Table 9-3 Excel data format for cell group setting ...............................................................217
Table 9-4 Example of cell parameters ................................................................................218
List of Figures
Figure 1-1 WCDMA networking .......................................................................................... 17
Figure 2-1 Starting BSC6800 OM ....................................................................................... 20
Figure 2-2 Starting BSC6800v1.7 OM................................................................................. 21
Figure 2-3 Signalling tracing at standard interfaces of single subscriber .............................. 23
Figure 2-4 Modifying advanced parameters ........................................................................ 23
Figure 2-5 Starting TraceViewer ......................................................................................... 24
Figure 2-6 Tracing signaling at standard interfaces of BSC6800 single subscriber in RNCv1.7
.................................................................................................................................... 25
Figure 2-7 Modifying the version output format ................................................................... 26
Figure 2-8 Starting TraceViewer in RNCv1.7....................................................................... 27
Figure 2-9 Tracing connection performance of single subscriber ......................................... 29
Figure 2-10 Tracing cell performance ................................................................................. 31
Figure 2-11 Tracing cell performance with a chart in RNCv1.7 ............................................ 32
Figure 2-12 Tracing cell performance with a list in RNCv1.7 ............................................... 32
Figure 2-13 Tracing BSC6800 calls .................................................................................... 34
Figure 2-14 Tracing BSC6800 calls in RNCv1.7.................................................................. 34
Figure 2-15 Tracing B SC6800 protocol messages at transport network layer ..................... 36
Figure 2-16 Tracing B SC6800 protocol messages at transport network layer in RNCv1.7 .. 36
Figure 2-17 Tracing BSC6800 MNCDT in RNCv1.7 ............................................................ 38
Figure 2-18 Tracing BSC6800 intra-frequency MNCDT in RNCv1.7 .................................... 38
Figure 2-19 Tracing BSC6800 inter-frequency MNCDT in RNCv1.7 .................................... 39
Figure 2-20 Tracing BSC6800 inter RAT MNCDT in RNCv1.7............................................. 39
Figure 2-21 CDT startup interface in V29 (tracing based on UE ID)..................................... 40
Figure 2-22 IFTS startup interface in V29 ........................................................................... 41
Figure 2-23 User plane tracing parameter setting interface for the CDT .............................. 42
Figure 2-24 MML command client interface ........................................................................ 43
Figure 2-25 Starting BSC6800 MML ................................................................................... 44
Figure 2-26 Starting BSC6800V1.7 MML commands .......................................................... 45
Figure 2-27 Querying key words by executing BSC6800 MML command............................ 49
Figure 2-28 Querying key words by executing BSC6800v1.7 MML command ..................... 49
Figure 2-29 BSC6800 OM console ..................................................................................... 50
Figure 8-9 File configuration for comparison with the baseline parameters.........................176
Figure 8-10 Parameter comparison between different cells in one MML script ....................177
Figure 8-11 File configuration for parameter comparison between different cells in one MML
script ..........................................................................................................................178
Figure 8-12 (RNC-level and cell-level) parameter comparison between different RNCs......178
Figure 8-13 Parameter comparison between different RNCs..............................................179
Figure 8-14 Parameter comparison between different versions of an RNC .........................180
Figure 8-15 Parameter configuration for parameter comparison between different versions of
an RNC ......................................................................................................................180
Figure 9-1 Tracing BSC6800 CDT .....................................................................................193
Figure 9-2 CDT messages ................................................................................................194
Figure 9-3 Viewing CHR through Insight Plus ....................................................................195
Figure 9-4 Format of classified command parameters........................................................196
Figure 9-5 Parameter matching format ..............................................................................197
Figure 9-6 Configuration format of special command parameters.......................................197
Figure 9-7 .NET Framework2.0 installation(1) ....................................................................202
Figure 9-8 .NET Framework2.0 installation(2) ....................................................................203
Figure 9-9 .NET Framework2.0 installation(3) ....................................................................203
Figure 9-10 SQL Server2005 installation(1) .......................................................................204
Figure 9-11 SQL Server2005 installation(2) .......................................................................205
Figure 9-12 SQL Server2005 installation(3) .......................................................................205
Figure 9-13 SQL Server2005 installation(4) .......................................................................206
Figure 9-14 SQL Server2005 installation(5) .......................................................................206
Figure 9-15 SQL Server2005 installation(6) .......................................................................207
Figure 9-16 SQL Server2005 installation(7) .......................................................................207
Figure 9-17 SQL Server2005 installation(8) .......................................................................208
Figure 9-18 SQL Server2005 installation(9) .......................................................................208
Figure 9-19 SQL Server2005 installation(10) .....................................................................209
Figure 9-20 SQL Server2005 installation(11) .....................................................................209
Figure 9-21 CME server configuration information (1) ........................................................210
Figure 9-22 CME server configuration information (2) ........................................................210
Figure 9-23 Opening the RNS on the CME server .............................................................210
Figure 9-24 Version selection ............................................................................................ 211
Figure 9-25 Opening parameter configuration on the CME server ...................................... 211
2007-12-13 All rights reserved Page13 , Total220
WCDMA OMC Operation Guide
Internal Open
Key words:
MML command, RTWP, starting simulated load, tracing signaling of single subscriber,
and OM
Abstract:
The document includes the operations in equipment room for radio network planning
and optimization engineers during the radio network optimization. It details operations
related to RNC, NodeB, M2000, core network, including tracing signaling of single
subscriber under RNC, MML command line, querying cell-related parameters,
collecting and converting RTWP data, starting simulated load on NodeB, querying
alarm data, tracing MSC subscribers, and extracting bill. It also describes related
precautions.
Acronyms and abbreviations:
1 Introduction
1.1 Contents
This document describes the operations in equipment room during radio network
optimization. It details operations related to RNC, NodeB, M2000, and core network.
The chapters are arranged according to operations of importance sequence by
engineers, including the following sections which describe the most frequently-used
functions.
1) Rules and precautions in equipment room
It describes rules and precautions to be followed by RNP&O engineers in equipment
room.
2) BSC6800 (RNC) OM
It introduces the following of BSC6800 (RNC):
l Tracing signaling at standard interfaces of single subscriber
l Tracing connection performance of single subscriber
l Tracing cell performance
l Tracing call
l Querying cell-related parameters
l Editing and executing MML command line and batch processing scripts
l Traffic measurement
l Exporting and uploading CFGMML files
l Extracting CHR logs
l Extracting Profile files
3) M2000 OM system
It includes the following in M2000:
l Starting and stopping simulated load on a batch of NodeB
l Methods for editing scripts of starting and stopping simulated load
l Methods for exporting NodeB name
l Querying NodeB IP address in M2000
l Querying and saving alarm data in M2000
4) NodeB OM
It includes starting and stopping simulated load on single NodeB, MML command of
NodeB. It details collecting and converting RTWP data on a single NodeB, querying
and extracting alarm information on NodeB.
5) OM at core network side
It includes the following under MSC:
l Tracing UEs
l Querying bills
l Viewing bills
l Extracting bills
6) Querying alarm
It includes:
2007-12-13 All rights reserved Page16 , Total220
WCDMA OMC Operation Guide
Internal Open
& Note:
Based on version 1.6, the operation and maintenance part of RNC and NodeB of version 1.7 is newly
added in this document.
In Figure 1-1, RNP&O engineers must pay more attention to RAN network side. RNC is
connected to:
l NodeB through the lub interface
l MSC of core network through the lu-CS interface
l SGSN of core network through the lu-PS interface
l Other RNCs through the lur interface so that RNCs exchange information with
each other
l Cell broadcast center (CBC) through the lu-BC interface
Wherein, BSC6800 represents Huawei RNC model in the following chapters.
Different IP addresses are assigned for different WCDMA network and OM clients, so
user names and passwords are different. Equipment room operators manage and
distribute user names and passwords uniformly, so you must follow rules in equipment
room in using user names and passwords.
1.3 Introduction
The document includes the operations in the equipment room for radio network
planning and optimization engineers during the radio network optimization. It helps
them analyze routine network optimization problems, such as call drop, handover, and
pilot pollution. This document details operations related to the RNC, NodeB, and
M2000, including tracing signaling of single subscriber under the RNC, MML command
line, tracing signaling in both user plane and control plane, collecting and converting
RTWP data, tracing real-time performance and cell performance. Different items are
traced in different test tasks. The following section introduces the above-mentioned
items by taking the equipment room of a site as an example.
There is an RNC and a core network, and an M2000 at the site. The following table lists
the IP address, user name, and password of each NE:
Before performing operations in the equipment room, you must identify IP address,
user name, and password of each NE to avoid mistakes. For example, to telnet to
NodeB, you must configure necessary routes.
& Note :
Generally, the IP address of the RNC is different from that of the NodeB. To maintain the NodeB remotely,
you need to run the following commands to add a BAM route to RNC:
2007-12-13 All rights reserved Page18 , Total220
WCDMA OMC Operation Guide
Internal Open
l For the RNC, run the command route add 12.11.0.0 mask 255.255.0.0 10.238.23.95 - p.
l For the M2000, run the command route add 12.11.0.0 mask 255.255.0.0 10.238.23.84 - p.
If the LMT is connected with a LAN switch of RNC, the next hop is RNC. If the LMT is connected with a
LAN switch of M2000, the next hop is M2000. For details about route configuration, see documents related
to the BSC6800.
2 RNC OM System
Caution:
l Select a proper software language (English or Chinese) and make sure that the version number
(BSC6800V100R005C01B068 for example) is consistent with that of the equipment room.
When you install the software BSC6800 OM version in RNCv1.5, you can double-click
the setup.exe,and then select the language English or Chinese.
When you install the software BSC6800 OM version in RNCv1.7, you can double-click
the setup.bat,and then select the language English or Chinese.
To start BSC6800, perform the following steps:
& Note:
In RNCv1.6, traced items are saved at <installation directory>\client\output\main\BSC6800\
BSC6800V100R006C01B040\trace in the trace management directory by default. The files are saved in
the format of office direction name_trace type_year-month-date-hour-minute-second.tmf.
Monitored data of traced items is saved at <installationdirectory>\adaptor\clientadaptor\BSC6800\
BSC6800V100R006C01B040\output\realmonitor in the real-time performance monitor directory by def
ault. The files are saved in the format of monitor type_monitor item_year-month-date-hour-minute-
2007-12-13 All rights reserved Page21 , Total220
WCDMA OMC Operation Guide
Internal Open
second.txt.
The name of the saved BSC6800V100R006C01B040 file varies with versions.
In RNCv1.7 and later version, MNCDT monitoring is newly added. It is saved at <installation directory>\
client\output\
main\BSC6800\BSC6800V100R007C01B061\trace. The file is saved in the format of office direction
name_trace type_year-month-date-hour-minute-second.
The system has the function of memorizing IMSI ID automatically.
2.2.1 Background
When locating problems, such as call drop, you need view signaling reported by the UE
before call drop and analyze the signaling based on signaling recorded at RNC side.
Provided with IMSI number, you can enable tracing signaling at standard interfaces of
single subscriber under RNC.
2.2.2 Procedure
& Note :
You report the last four digits of IMSI to equipment room operators, because the first 11 digits are the fixed.
For example, an IMSI in a WCDMA network is "45419500000****". The first 11 digits vary in different
WCDMA networks.
5) Click Advanced. A dialog box Advanced for modifying parameters pops up. At
this interface, you can modify the directory to save data, the maximum messages
per window, flow control types, and message colour.
6) Click OK.Tracing starts. When the tracing is complete, stop tracing by shutting
down the window. Or you can stop tracing by selecting Stop tracing in the menu.
You must start and read the traced signalling by using the BSC6800 TraceViewer
of the same version. Otherwise, an error occurs upon tracing the signalling file.
The BSC6800 TraceViewer is integrated to LMT OM system of BSC6800, with the
starting interface as shown in Figure 2-5.
& Note :
Typically, you need to report the last four digits of IMSI to equipment room operators, because the first 11
digits are always the same.
For example, an IMSI in a WCDMA network is "45419500000****". The first 11 digits may vary in different
WCDMA networks.
4) Typically, select All standard interface message for the signaling tracing of a
single UE on standard interfaces. You can also select Specify standard interface
2007-12-13 All rights reserved Page24 , Total220
WCDMA OMC Operation Guide
Internal Open
message for signaling tracing on some of the standard interfaces. In this case,
select one or more out of the lub interface, lu interface, Uu interface, and lur
interface in the Select standard interface message pane.
Figure 2-6 shows signalling tracing at standard interfaces of a single subscriber.
Figure 2-6 Tracing signaling at standard interfaces of BSC6800 single subscriber in RNCv1.7
5) Click Save as. You can modify the path where the data is to be saved.
6) Click OK. The tracing starts.
7) When the tracing is complete, stop the tracing by shutting down the window. You
can also stop the tracing by selecting Stop tracing in the menu. You must open
and read the traced signalling by using the BSC6800 TraceViewer of the same ve
rsion. Otherwise, the traced result cannot be opened. The BSC6800 TraceViewer
is integrated to LMT. When the LMT is started, the user interface is as shown in Fi
gure 2-5.
& Note:
l For the same IMSI, the system traces signaling at standard interfaces of single subscriber for one time
under RNC. If you trace single subscriber on one LMT, you cannot trace the signaling of the same
subscriber on another LMT.
l Under the same RNC, the current version of Trace Viewer supports tracing signaling at standard
interfaces of six single subscribers at most at the same time. When multiple engineers start tracing
signaling at standard interfaces of single subscriber at the same time for test, they need coordinate
resources.
l During tracing signaling at standard interfaces of single subscriber, closing Trace window and clicking
Stop Tracing are different.
l Close Trace window to export log file for tracing. Copy the file, send it to related engineers, and delete
the file in time.
l When you click Stop Tracing, The log file to be traced is not closed. Copy the imported log file, and
save it. If the file is deleted, data is missing upon next recording.
2.3.1 Content
When locating problems such as call drop, you need analysis the problems based on
tracing connection performance of single subscriber recorded at RNC side. Provided
with IMSI number, you can enable Tracing connection performance of single subscriber
under RNC.
During routine test of network optimization, you usually trace the following four
connection performances:
l UL SIR (measured SIR in radio uplink set)
l UL SIRtarget (target SIR in radio uplink set)
l UL BLER (BLER on uplink transmission channel)
l DL Tx Code Power (downlink transmit code power)
You might also trace the following connection performances:
l PCPICH (Ec/No&RSCP)
l AMR mode
l DL BLER (downlink block error rate)
l HO delay (handover delay)
l DL throughput & bandwidth
l UL throughput & bandwidth
l DL traffic vol (downlink traffic volume)
l UL traffic vol (uplink traffic volume)
l UL Phy BER (uplink physical channel bit error rate)
l UE TxPower (UE transmit power)
l UL SIRerror (uplink signal-to-interference ratio error)
2.3.2 Procedure
2) Type the IMSI of the subscriber to be traced and click OK.Tracing connection
performance of single subscriber starts. The system automatically saves the
tracing file in the default directory.
3) Close the window or right click on the menu after tracing, and select Stop
monitoring to stop tracing
The method for tracing Connection performance of UL SIRtarget, UL BLER, and DL Tx
Code Power is similar with that of UL SIR. The difference lies in that you select UL
SIRtarget, UL BLER, or DL Tx Code Power in Monitoring item drop-down menu.
2.4.1 Content
When locating problems in a cell, you need view the performance specifications of the
cell. If you have the RNC ID and cell ID, you can start tracing cell performance on
BSC6800. Cell performance usually includes:
1 PCPICH TxPower (transmit power of cell PCPICH pilot)
2 Tx Carrier Power (transmit power of cell downlink carrier)
3 DCH Subscriber Num (number of DCH subscribers of cell)
4 CCH Subscriber Num (number of CCH subscribers of cell)
5 Cell Code Tree (monitoring cell code tree)
In RNCv1.7, Cell User NUM (number of cell subscribers) and Cell Cmb UserNum
(number of cell cmb subscribers) are newly added. DCH User Num (number of cell
dedicated channel subscribers) and CCH User Num (number of cell common channel
subscribers) are deleted.
RNCv1.7 enhances the function of monitoring Cell User NUM, combines DCH User
Num with CCH User Num, and adds the function of monitoring the number of HSPDA
subscribers. As a result, it can monitor DCH User Num, CCH User Num, and the
number of HSPDA subscribers in the same performance monitoring task.
You might also trace the following cell performances:
1 HS-DSCH Provide Bit rate (bit rate provided by HS-DSCH)
2 HS-DSCH Min Power Required (minimum power of HS-DSCH)
3 DL Total Equivalent User Monitor (downlink total equivalent user monitor)
4 UL Total Equivalent User Monitor (downlink total equivalent user monitor)
5 DL CAC Monitor (downlink access grant judgment monitor)
6 UL CAC Monitor (downlink access grant judgment monitor)
7 Node Sync (node synchronization)
8 RTWP (received total bandwidth power)
2.4.2 Procedure
In RNCv1.7, you do not need to enter the RNC ID when starting tracing cell
performance. Only the cells of the local RNC can be traced, so it is redundant to enter
the RNC ID. In addition, an incorrect RNC ID may cause that the system cannot give
2007-12-13 All rights reserved Page32 , Total220
WCDMA OMC Operation Guide
Internal Open
Figure 2-15 shows tracing B SC6800 protocol messages at transport network layer.
Figure 2-16 Tracing B SC6800 protocol messages at transport network layer in RNCv1.7
In addition to CDT tracing by UE ID (IMSI, TMSI, or IMEI), a cell such as the IOS can be
specified; the system can then randomly select a UE to perform CDT tracing. This is
called IFTS. The IFTS tracing specially applies to the case in which the fault is known
but the UE ID cannot be determined.
The CDT/IFTS provides a powerful user plane tracing function. We introduce the
following common user plane tracing settings. To locate general network problems,
select Periodically Data Report and set the period to two seconds and L2 Data
Report Time to zero seconds or ten seconds. If the user plane data is required to
locate a problem (for example, TRB resetting problem), set L2 Data Report Time to
100 seconds to guarantee that there is enough data for problem location.
Figure 2-23 User plane tracing parameter setting interface for the CDT
1.Click the arrow next to History Command to display the previously executed
command. At this time, you can modify some parameters. Repeat this step to modify
other parameters.
2.Click the drop-down list next to Command Input (F5) to display the 20 recent history
commands and their parameter configurations. You can selectively repeat the
operation.
NE window: The window displays the NEs that can issue MML commands, in the
topological view according to the NE topology structure.
MML command navigation tree window: The window displays the MML command
navigation tree of the specified NE.
Command output window: The window consists of the General Maintenance tab,
History Command tab, and Help Information tab. The General Maintenance tab
displays the issued commands and the execution results. The History Command tab
lists the executed commands and their parameter configurations. The Help
Information tab displays the help information about MML commands.
Command display window: The window displays the commands to be executed and
their parameter configurations.
Executed command list window: The window displays all executed MML commands
and the number of commands that each NE has executed.
Command input window: The window contains History Commands, Command Input,
and Command Parameters. History Commands displays the 20 recent history
commands and their parameter configurations.
The M2000 may generate several packets if any of some commands are executed. When these
commands are executed on the M2000, the General Maintenance tab displays only the first packet. You
can query subsequent packets in the Subsequent Packet Browsing window.
& Note:
As shown in Figure 2-25,
l Parameters in red are mandatory.
l Parameters in black are optional.
4) For RNCv1.7, click the icon BSC6800 OM to start the MML Client operation
interface. Type commands in Command Input field and fill in with related
& Note:
As shown in Figure 2-26,
l Parameters in red are mandatory.
l Parameters in black are optional.
Table 2-3 lists classified BSC6800 MML commands used in radio network planning and
optimization. Complete commands in RNC are queried through Search function in
BSC6800 OM help system.
Table 2-3 BSC6800 MML commands used in radio network planning and optimization
Equip
Type Command Detailed operation Remarks
ment
Cell name
Commands
Frequency
for querying Command for querying
Scramble
RNC cell states cell data includes:
Maximum transmit power
and LST CELL
TimeOffset
parameters
Corresponding NodeB name,
2007-12-13 All rights reserved Page45 , Total220
WCDMA OMC Operation Guide
Internal Open
Equip
Type Command Detailed operation Remarks
ment
LAC.
Five cell states include:
Cell is setup and enabled (normal)
Command for querying Cell is setup and disabled (abnormal)
cell state includes: Cell is not setup (abnormal)
DSP CELL Cell is not active (deactivation)
Cell is being blocked (blocked on
RNC)
Commands in the left stands for:
Querying adjacent intra-frequency
cells
Commands for querying
Querying adjacent inter-frequency
neighbor cell information
cells
include:
Querying neighbor GSM cells
LST INTRAFREQCELL
Querying neighbor RNC cells
LST INTERFREQCELL
Note that the parameter SRN is added
LST GSMNCELL
in the commands in RNCv1.7,
LST NRNCCELL
including LST GSMNCEL, LST
INTRAFREQNCELL, and LST
INTERFREQNCELL.
Commands in the left stands for:
Activating/Deactivating cell. Then View the cell
logical cells and NodeB local cells are state using
Commands for modifying
removed, the power amplifier is on, DSP
cell state include:
and transmit channel is closed command.
ACT/DEA CELL
Blocking/Unblocking cell. Then local Unblock the
BLK/UBL CELL
cells and NodeB local cells exist, cell if NodeB
RMV CELL
power amplifier is on, but transmit administratives
channel is closed tate = blocked
Removing cell
Equip
Type Command Detailed operation Remarks
ment
The BANDIND range is added in the transmit power
command ADD/MOD CELLSETUP. before
executing
commands,
otherwise, the
maximum and
minimum
default value of
PCPICH are
34.6 dBm and
31.3 dBm.
Commands for querying
and modifying algorithm Commands in the left stands for:
parameters include: Querying/Setting global algorithm
LST/SET parameters
CORRMALGOSWITCH Querying/Modifying cell algorithm
LST/MOD parameters
CELLALGOSWITCH
HSDPA power
can be divided
statically and
dynamically.
When you set
HS-PDSCH
Commands in the left stand for: AND
Creating parameters related to HS-SCCH
Command for creating
HSDPA cell configuration POWER, if the
Commands an HSDPA cell: ADD
Modifying parameters related to specified
for creating CELLHSDPA;
HSDPA cell configuration power is
and modifying Command for modifying
The value range of the parameter inconsistent
HSDPA HSDPA cell
HsPdschMPOConstEnum for the with that of the
configuration configuration: MOD
command ADD CELLHSDPA&MOD power
CELLHSDPA
CELHSDPA changes from -4dB to amplifier, the
19dB. power is
divided
statically;
otherwise the
power is
divided
dynamically.
Currently, up to
20 HSUPA
subscribers
can be
supported.
Therefore, set
Command for creating
E-AGCH and
Commands an HSUPA cell: ADD
E-RGCH/E-HI
for creating CELLHSUPA; Commands in the left stand for:
CH to 1. You
and modifying Command for modifying Adding a cell HSUPA parameter
must set the
HSUPA HSUPA cell Modifying a cell HSUPA parameter
ratio between
configuration configuration: MOD
the power
CELLHSUPA
received by
E-DCH not
providing
service and
that received
by the total
Equip
Type Command Detailed operation Remarks
ment
E-DCH
depending on
network
planning
There are enough MML commands used on RNCs, so you can query them by using
key words through Search function in BSC6800 OM, as shown in Figure 2-27. Type
key words in Key field, enter, and the corresponding MML command is displayed.
& Note:
The person responsible for modifying RNC MML command parameters is known. For details, see 9.2 .
You can use MML command line directly to execute one or two commands on
BSC6800. When repeating executing the same command (such as for adding
hundreds of neighbor cells), you need not execute commands one by one by hand
because it wastes time and causes mistakes. BSC6800 LMT provides powerful batch
processing function. For example, if you create correct batch processing scripts for
adding neighbor cells, you can use it to add hundreds of neighbor cells quickly.
The following procedure introduces a method for editing scripts to add intra-frequency
neighbor cells, using UltraEdit, a text file editing software. You can use multiple
methods for editing scripts, or import scripts automatically by database.
1) Click icon in BSC6800 OM, and switch to MML Client window. Type "ADD
INTRAFREQCELL" in Command Input field, and enter. An interface appears as
shown in Figure 2-29.
& Note:
l Options in red are mandatory.
l Options in black are optional.
l If you fill nothing in the field, you are to use the preset parameters by default.
2) Type cell ID, RNC ID, and neighbor cell ID in corresponding fields. A complete
and executable command appears in the command line. Click icon to
execute the command
3) Copy the command from editing box to a text file
Use UltraEdit software, because it can easily perform column editing.
For example, if you add 20 intra-frequency neighbor cells on RNC1, you must copy
the command 20 times by using UltraEdit. Because you add intra-frequency
neighbor cells, you use the similar command and modify the corresponding
parameters. The command is as below:
ADD INTRAFREQCELL: CELLID=12345, RNCID=1, NCELLID=23456,
READSFNIND=NOT_READ, CELLINDIVIDALOFFSET=0,
CELLSFORBIDDEN1A=AFFECT, CELLSFORBIDDEN1B=AFFECT,
QOFFSET1SN=0, QOFFSET2SN=0;
In the previous command line, a complete command consists of command, colon
(:), parameters (separated by commas), and semicolon. In the command, you
need modify parameters corresponding to CELLID, RNCID, and NCELLID.
4) Select Column > Column Mode
You can edit the text file. Column editing function of UltraEdit helps you easily
modify parameters corresponding to CELLID, RNCID, and NCELLID.
To cancel the operation, reselect Column > Column Mode.
Figure 2-30 shows starting column editing function in UltraEdit software.
Use Excel file for adding list of neighbor cells because it is easy for editing and
processing scripts. In the column operation mode of UltraEdit, select column field of
CELLID, RNCID, and NCELLID respectively, copy corresponding field from Excel file
containing neighbor cell list, and paste the field in the corresponding field area. Editing
scripts is complete.
Figure 2-31 shows the column editing.
1) Click icon in BSC6800 OM, and switch to MML Client window. Type "ADD
INTRAFREQCELL" in Command Input field, and press Enter.
An interface appears as shown in Figure 2-32.
& Note:
l Options in red are mandatory.
2) Type cell ID, RNC ID, and neighbor cell ID in corresponding fields.
BSC6800 is powerful in batch processing. After editing a batch processing script, you
can use the script on BSC6800 LMT, execute the batch processing, and save the
executing result.
To execute BSC6800 batch processing scripts, perform the following steps:
1) Set the result of executing batch processing scripts to automatic saving. In the
menu column of BSC6800 OM, select System > System Configuration and an
interface appears as shown in Figure 2-33.
2) Click Save as in the System Configuration dialog box. This saves the output of
batch processing to be executed as a file, and in the file you can view executing of
batch processing command. After executing the script, you can cancel the saving
option and send result to related engineers so that the engineers check that the
2007-12-13 All rights reserved Page53 , Total220
WCDMA OMC Operation Guide
Internal Open
3) Select System > Execute Batch Commands in the BSC6800 menu bar to
execute batch processing scripts. An interface appears as shown in Figure 2-35.
4) In the Execute Batch Commands dialog box, click Browse, select the batch
processing script to be executed, and click Open
The batch processing script is started, as shown in Figure 2-36.
l If you execute a batch processing script at once, select Execute now and
Operator Interface, then the commands are executed one by one. If an error
occurs in MML command, the executing stops and the system prompts the error.
Operator interference might stop executing batch processing scripts or ignore the
MML command for continuous executing. If you do not select Operator Interfere,
click OK directly, BSC will execute the batch processing script automatically. If an
error occurs in MML command, the system executes the next command, ignoring
the MML command with error.
l If you need modify multiple parameters and execute multiple scripts, executing
scripts might affect the system greatly. Therefore you need set the system so that
the system automatically starts executing the script at 0:00 and saves result.
Select Execute by schedule and fill the time for executing the script.
& Note:
l To ensure the operation security and solve problems in time, Huawei prohibits executing customized
scripts.
l You must select Operator Interfere when executing batch processing scripts, to avoid SPU reset.
Huawei has a technique inform on this, and it is a bug of B150SP01.
l Executing scripts automatically is not recommended during executing batch processing scripts. If you
need modify much data, do it at night.
Figure 2-38 shows customized time for executing batch processing in BSC6800 OM.
Select Stop Saving to stop saving the result of executing script, send the result file to
related engineers so that they check that commands are executed correctly. Operators
can directly open the text file to check the result of executing script.
Errors occurring in executing batch processing include:
l Wrong command word of script
l Error during adding neighbor cells, such as non-existent cells, conflicting
scrambles of neighbor cells, and over 31 neighbor cells
l Improper configuration of parameters, such as parameters beyond range
l Improper sequence of executing script, such as modifying maximum and minimum
value of pilot power before modifying pilot power
To execute BSC6800 batch processing script on RNCv1.7, perform the following steps:
1) Configure the results of batch processing scripts to be saved automatically.
In the menu column of BSC6800 OM, select System > Output Windows Setting
and an interface appears as shown in Figure 2-40.
2) Click Save as in the Output Windows Setting dialog box. This saves the output
of batch processing to be executed as a file, and in the file you can view the exec
ution of the batch processing command. After executing the script, you can cance
l the saving option and send result to related engineers so that the engineers che
ck that the command is executed correctly.
Figure 2-41 shows saving result of batch processing in BSC6800 OM.
3) Select System > Batch Commands in the BSC6800 menu bar to execute batch
processing scripts
An interface appears as shown in Figure 2-42.
4) In the Batch Commands dialog box, click Browse, select the batch processing s
cript to be executed, and click Open.
The batch processing script is started, as shown in Figure 2-43.
& Note:
l To ensure operational security and solve problems in time, Huawei prohibits the execution of
customized scripts.
l You must select Manual Mode when executing batch processing scripts, to avoid SPU reset. Huawei
has a technique inform on this, and it is a bug of B150SP01.
l Executing scripts automatically is not recommended during the execution of batch processing scripts.
If you need to modify a lot of data, do it at night.
Figure 2-44 shows customized time for executing batch processing in BSC6800 OM.
Select Auto Save or Timed Save to save the result of script execution, send the result
file to related engineers so that they check that commands have been executed
correctly. Operators can directly open the text file to check the result of script execution.
Errors occurring in executing batch processing include:
l Wrong command word of script
l Error during adding neighbor cells, such as non-existent cells, conflicting scramble
of neighbor cells, and exceeding 31 neighbor cells
l Improper configuration of parameters, such as parameters beyond range
l Improper sequence of executing script, such as modifying maximum and minimum
value of pilot power before modifying pilot power
RNP&O engineers need know actual parameters in RNC operation, to judge whether
the actual parameters are consistent with the configured parameters, and to query data
related to RNC upon solving problems. Therefore the engineers need export data
configuration file CFGMML.txt from RNC, in two ways:
The method of exporting CFGMML files in RNCv1.7 is almost the same as that in
RNCv1.5. The only difference lies in the mode of starting the FTP client. For RNCv1.5,
2007-12-13 All rights reserved Page64 , Total220
WCDMA OMC Operation Guide
Internal Open
you need to start the FTP embedded in RNCv1.5 OM and upload the CFGMML file to
your computer from BAM. Then click the icon on the toolbar in BSC6800 OM to
start the FTP client; while for RNCv1.6 and later, to start the FTP client, you can double
click [Installation]:\HW LMT\client\ftpclient\bin\FTPClient.exe or select Huawei
local maintenance terminal. The subscriber name is "FtpUsr", and the password is
"rncadmin". Different user names and passwords are used in different equipment
rooms, so you can ask for them from the equipment room manager.
& Note:
l The exported file is in the .txt format. The file name is CFGMML-time.txt by default.
l The file is saved in \BAM\FTP on the BAM server by default.
CHR log is a detailed call record in RNC, helpful to call drop and access problem
analysis by engineers. You can view CHR logs by using Nastar of version superior to
4.0 (you cannot view CDL of RNC of version inferior to 1.3) or by using Insight plus. For
how to use Insight plus, see 8.5.4.
CHR log is automatically saved by RNC:
l In BAM installation directory of BSC6800, such as
D:\Bsc6800\BAM\LoadData\FamLogFmt.
l In format of shelf number of RNC + Log + time.log, such as
09Log20050424000044.log.
The first two digits stand for the number of the frame of NodeB configured on RNC.
Digits after "Log" stand for the time when CHR log is saved.
l For RNCv1.5, in the format of shelf number of RNC + Log + start time_end
time.log.bz2, such as 01Log20060217000017_20060217030504.log.bz2.
l For RNCv1.6, in the format of shelf number of RNC + Log + start time_end
time.log.bz2, such as 05Log20060612000208_20060612235828.log.bz2.
l For RNCv1.7, in the format of shelf number of RNC + Log + start time_end
time.log.bz2, such as 03Log20061026000108_20061026235711.log.bz2.
Traffic measurement data files are periodically saved by the RNC, one file every half an
hour. You use the file for analyzing traffic measurement data through Nastar software.
The traffic measurement file imported into Nastar tool is the original data file, unrelated
to whether traffic measurement tasks are registered.
During routine work in equipment room, extract all RNC1.3 traffic measurement data of
previous day in FTP\PerfFile on BAM server of BSC, all RNC1.5 data in
FTP\MeasResult. The file for one day is about 32 Mbit, too large to send by Email.
Different project teams have different rules on how to obtain large traffic measurement
file from equipment room.
RNC1.3 traffic measurement files are saved in installation directory on BAM in
BSC6800, such as D:\BSC6800\BAM\FTP\PerfFile.
RNC 1.3 traffic measurement files are named by default in the format of PerfFile + data
+ time + RNCID.xml.
RNC1.5 traffic measurement files are saved in installation directory on BAM in
BSC6800, such as D:\BSC6800\BAM\FTP\MeasResult.
RNC 1.3 traffic measurement files are named by default according to time, such as
A20060215.0000+0800-0100+0800_EMS-NORMAL.mrf.bz2.
Customizing and extracting traffic measurement data in RNCv1.6:
Traffic measurement of RNCv1.6 falls into M2000 version and NASTAR version. Traffic
measurement of M2000 inherits that of RNCv15, customized by M2000. You can query
traffic measurement through M2000. For this version, traffic measurement files within
72 hours are saved in D:\BSC6800\BAM\FTP\MeasResult.
Traffic measurement of NASTAR serves the NASTAR software. It is a full-index traffic
measurement file. Usually we use this file. It is saved in
D:\BSC6800\BAM\FTP\NastarResult. You can download the above-mentioned two
types of traffic measurement files through FTP.
The system names traffic measurement files based on time by default, such as
A20060313.0000+0800-0030+0800_NASTAR.mrf.bz2.
Customizing and collecting traffic measurement data in RNCv1.7:
The method of extracting traffic measurement in RNCv1.7 is almost the same as that in
RNCv1.6.
The system names traffic measurement files based on time by default, such as
A20060313.0000+0800-0030+0800_NASTAR.mrf.bz2
Traffic measurement extracted from M2000 is saved in D:\BSC6800\BAM\FTP\
MeasResult, such as A20061027.1630+0800-1700+0800_EMS-NORMAL.mrf.bz2.
Traffic measurement extracted from NASTAR is saved in D:\BSC6800\BAM\FTP\
NastarResult, such as A20061027.1630+0800-1700+0800_EMS-NASTAR.mrf.bz2.
IOS is short for intelligent optimization system. You need to start IOS tracing on RNC
OM console. This function is similar to tracing a single subscriber, but you do not need
to enter the subscriber IMSI.
Since IOS tracing affects the system operation, you are recommended to set Max calls
simultaneously traced to a smaller value and not to trace all events at the same time.
The file is named in the format of .tmf, such as RNC1_IOS_2006-04-13-16-08-02.tmf.
The file is saved on the local OM console where you start IOS tracing. The file path an
d name can be changed. The file is saved at \HW LMT\client\output\main\BSC6800\
BSC6800 version\trace by default.
& Note:
HSDPA call Trace is newly added in RNCv1.7. Three types of call messages are added:
l CALLTARCE_IND_HS_DSCH_RL_ACTIVED
l CALLTARCE_IND_HS_DSCH_SERVING_RL_CHANGED
l CALLTARCE_IND_HS_DSCH_RL_DEACTIVED
Start IOS tracing or UE (both signaling plane and user plane) on LMT.
3 M2000 OM System
3.1.1 Functions
3.1.2 Procedure
You perform starting and stopping simulated load on NodeB in M2000 in equipment
room, but only authorized super subscribers can use the function in M2000. Equipment
room operators manage and distribute user names and passwords uniformly. The
password to the super user is in the charge of specified managers in equipment room,
so you must follow rules using it.
2) Click the icon MML Command in M2000, to switch to M2000 MML command line
interface, as shown in Figure 3-2
l The system allows the MML command packets in which the state is COMPLETED to be
cleaned.
l When the system is issuing an MML command, the options Export All and Clean Packets are
disabled.
l Before you clean packets, the system displays a dialog box, prompting you whether to export
the packets. If you click Yes, the system saves the exported packets to the path you have selected.
If you click No, the system does not save the reported packets.
3 Select one or more NEs in the navigation tree. When the M2000 receives the
subsequent packets from the selected NEs, a prompt is displayed in the output
window of the system and at the lower right side of the client.
In the Subsequent Packet Browsing window, you can perform the following operations on the displayed
packets:
l Click Clear or right-click and choose Clear Packet to clear all packets from the output window.
l Click Save or right-click and choose Save Window Text as to save the exported packets.
Right-click and choose Start Scrolling to start the scrolling display of packets.
Right-click and choose Pause Scrolling to pause the scrolling display.
l Before starting the CME of the NE, the corresponding version of the CME software
of the NE must be installed on the client PC of the M2000.
l The version of the installed CME must be consistent with the software version of
the NE. Otherwise, the CME cannot be started.
Background information
Only the CME of RNCs and NodeBs can be started.
Operation procedure
On the M2000 client, choose Tools > WRAN CME to start the CME client.
2 Run the EXP CFGDATA command, with no value specified for the Viewname
parameter.
3 Log in to the FTP of the BAM and find the required CMECfgSyncView.zip file
in the /BAM/VersionA/FTP/ExportCMESyncView/ directory.
The method of obtaining the BCP compression file of an NE in V29072 is slightly
different. The command to be executed contains an additional parameter MOC ID.
Before running the command, type All in this field. The path is the same as the one
used for the preceding command.
l On starting the LMT, if you find that the current user is bound to an NE, you can
automatically log in to the LMT as the user of the NE; if no user is bound to the NE,
you must specify the username and password.
l For a NodeB, when you start the LMT, the system automatically considers the
M2000 as the gateway of the LMT.
Operation procedure
3 Select the related measurements in the left pane (HSDPA Measurement Per
Cell under Measurements Related to HSDPA). The original counters are
generated.
4 Right-click in the right pane for customizing a counter and choose Add. In the
displayed interface, enter a counter name (HSDPA RLC Traffic Volume in MB)
and type in the formula. You do not need to enter each letter of the name of
each sub-counter involved, manually. Instead, you can enter several letters
(including punctuations) and the name of the corresponding sub-counter is
typed automatically. In this case, you can double-click the name of the
sub-counter; it is then entered in the Formula Information column
automatically. You can select the operators in the formula from the operator
column on the right side, instead of entering each of them manually.
Precautions:
Except 100 and 1000, there is no other constant in the operator column. If you want to
manually enter a constant, you must enclose it within parenthesis for example, {1024};
otherwise, a grammar error is displayed.
Example:
After HSDPA RLC Traffic Volume (Mbytes)
=<VS.HSDPA.MeanChThroughput.TotalBytes>/(1024*1024) is entered in the M2000,
[VS.HSDPA.MeanChThroughput.TotalBytes]/({1024}*{1024}) appears in the Formula
Information column.
After entering the formula, click Apply and OK. The customized counter formula is
completed.
3.7.1 Background
NodeBs are in large numbers. If you start simulated load on a batch of NodeBs in
M2000, the workload is heavy. To avoid this, you can perform batch processing
operations on NodeB by using M2000. According to the actual situation, the following
section describes the method for staring and stopping simulated load on NodeB.
On MML Command interface, M2000 classifies NodeB according to types of NodeB.
M2000 classifies NodeB to NodeB3806A, NodeB3806, NodeB3802C, and
NodeB3812.
In M2000, you can select NodeBs of one type for starting simulated load in batch
processing. Namely, you execute the following command to start simulated load of
various NodeBs according to types:
STR DLSIM: LR=50;
3.7.2 Procedure
3) Type "STR DLSIM" in the right Command Input (L), and enter
Local Cell ID and Load Ratio (%) text box are displayed.
If you type nothing in Local Cell ID text box, all cells under the NodeB will be loaded.
4) Type required ratio in Load Ratio (%) text field
Fox example, you type 50 in Load Ratio (%) text field to start 50% simulated load.
5) Click icon or press the shortcut key F9 to start simulated load on all NodeBs
6) The method for starting simulated load on NodeBs of different types, such as
NodeB3806, NodeB3802C, and NodeB3812 is similar to that of NodeB3806A.
& Note:
l During starting simulated load on NodeB of the same type, click the check box before the NodeB on
which you need not start simulated load, and then no ticks are displayed in the check box before
unselected NodeBs. Therefore these NodeBs with ticks are started simulated load, and those NodeBs
2007-12-13 All rights reserved Page80 , Total220
WCDMA OMC Operation Guide
Internal Open
without ticks are not started. For example, if you need not start simulated load on 3802_pohing_B,
801310_WarwickHouse_B, 801310_WarwickHouse_C, and 801170_KingHouse_A, you unselect
these four NodeBs and no ticks are displayed in the check box before them. Figure 3-7 shows starting
50% simulated load on NodeB 3802C.
l M2000 classifies NodeB according to NodeB types. If multiple RNCs are in the serving network,
NodeBs of the same type might be controlled by different RNCs. If you need start simulated load on all
NodeBs under an RNC, do not select NodeBs to be loaded one by one, start simulated load on NodeB
by using batch processing scripts, detailed in 3.10.2 .
l If you need start simulated load and change power of command channels in a project at the same time,
ensure to change power of command channels before you start simulated load. Because simulated
load volume is calculated based on CPICH as a benchmark, starting simulated load before changing
power of CPICH pilot causes that simulated load volume does not meet requirements.
& Note:
If you have not started simulated load on a NodeB, stopping simulated load on this NodeB leads to an RL
setup failure every 128 times. This problem will be solved in updated version of NodeB
V100R003C02B075
In Figure 3-9, if you start 36% simulated load on the cell, bar chart of Tx Carrier Power
is 36%. You can view starting simulated load on the cell by using this method.
Figure 3-10 shows displaying downlink transmit power of the cell when starting 50%
simulated load.
Figure 3-10 Displaying downlink transmit power of the cell 23191 when starting 36% simulated load
3.10.1 Editing Scripts for Starting and Stopping Simulated Load on NodeB in
M2000
In M2000, if you need start and stop simulated load on multiple NodeBs at the same
time, and NodeBs are not of the same type, starting and stopping simulated load on
NodeB one by one are difficult and easy to be wrong. M2000 provides batch processing
function, so you can start and stop simulated load on candidate sites quickly by editing
scripts in command format.
In M2000:
l The script for starting simulated load is
STR DLSIM: LR=50; {NodeB 1, NodeB 2,}
l The script for stopping simulated load is
STP DLSIM; {NodeB 1, NodeB 2,}
& Note:
l The commands for starting and stopping simulated load are ended with a semicolon.
l In the brace, the names of NodeBs on which simulated load is started and stopped are listed, including
that there is only one NodeB in the brace.
l If multiple NodeBs on which simulated load are started and stopped can be listed in the brace in one
command, or can be listed in multiple commands while a brace includes only one NodeB name, listed
as below:
STR DLSIM: LR=50; {NodeB 1}
STR DLSIM: LR=50; {NodeB 2}
l NodeB names must be consistent with names in M2000, otherwise M2000 cannot identify them. The
NodeB names are obtainable from RNP planning database, and exporting NodeB names from M2000
is strongly recommended. The section 3.11 introduces the method for exporting NodeB names.
To execute batch processing scripts for starting and stopping simulated load on NodeB
in M2000, perform the following steps:
1) Double-click the M2000 icon to start M2000 OM system
You can start and stop simulated load in M2000 only when authorized as an
administrator.
Figure 3-11 shows M2000 OM interface.
3) Click Add button, select edited scripts for starting and stopping simulated load on
NodeB, and click OK to start batch processing task1 for starting and stopping
simulated load on NodeB
4) Click Activate button after correctly exporting scripts for starting and stopping
simulated load on corresponding NodeBs. The system automatically executes
commands for starting and stopping simulated load on NodeB, as shown in Figure
3-13.
3) Click OK after selecting RNC1. M2000 exports information about all NodeBs
under RNC1.
4) Right click on NE Report interface, and select Save menu to save exported data
about NodeB as Excel format, as shown in Figure 3-16
The exported data about NodeBs from M2000 is in Excel format. In the Excel, NodeB
names are listed in column, so you can perform column-to-row conversion of NodeB
names in UltraEdit by selecting Format > Convert CR/LFs to Wrap.
Replace spaces between NodeB names with commas, but there must be no comma
after the last NodeB name.
Figure 3-17 shows performing column-to-row conversion of NodeB names in UltraEdit.
5) Copy all the NodeB names after editing, and paste them in the brace of STR
DLSIM: LR=50; { }.
You complete creating batch processing scripts for starting and stopping simulated load
on NodeB in M2000.
Figure 3-18 Replacing spaces between NodeB names with commas in UltraEdit
& Note:
l If multiple NodeBs on which simulated load are started and stopped are listed in multiple commands,
ensure each command includes only one NodeB name
l Replace spaces between NodeB names with commas, but there must not be a comma before the last
NodeB name.
l Object Selection
l Counter Selection
l Other Setting
2) After setting, click Save Template to save the setting as a template, which help
query of the same tasks
3) Click Query button in the Query interface
Figure 3-26 shows the traffic measurement data.
4) Click Save in the right lower corner to save traffic measurement data.
Before querying a customized counter in the M2000, you must enable the
measurement switch of the customized formula in the counter manager.
1) Choose Performance -> Measurement Management->Measurement Settings.
Select the unit to be measured from the pane on the right. For example, choose
Management Related to HSDPA -> HSDPA Management Per Cell.
2) Select the customized counter HSDPA RLC Traffic Volume (Mbytes) from the p
ane displayed on the right. In the right pane, Measurement related to HSDPA is
displayed in Function Set and HSDPA Measurement per cell is displayed in Fu
nction Subset.
3) Select the customized counter in the time granularity, click Apply at the lower-rig
ht corner, and wait for the items of the customized counter to be displayed. (Note:
There are two measurement periods for the M2000 to obtain measurements from
the BAM: 5 minutes and 15 minutes. In most cases, we select the 15-minute peri
od.)
The counter customization is now complete and the related measurement switches are
enabled to register the cells to be measured. After several measurement periods, you
can query the results.
2) From Available Counters in the Counter Settings page, select the counters to
be measured and click the arrow in the middle to view the Selected Counters.
3) In the Other Settings page, select a time mode, period, and data range accordin
g to the requirements.
4) Click Save Template. In the displayed page, enter the name of the query report a
nd the directory in which the query report is to be saved. In the example, the nam
e of the query report is monthlyreport_HSDPA and the directory is Monthly-rep
ort.
1) check whether the measurement between two cells is enabled on the LMT. If not,
enable the measurement between two cells on the RNC.
MML command: ADD MEASOBJ: MOC=CELL_GCELL;
After obtaining the traffic measurement data of a NodeB, the M2000 imports it to the
database and makes relevant treatments (for example, time summarization/cell
summarization) to help you query the traffic measurement indexes. On the M2000, you
can query the traffic measurement indexes of a NodeB in the same way as querying
2007-12-13 All rights reserved Page107 , Total220
WCDMA OMC Operation Guide
Internal Open
those of an RNC. For details, see "Customization and generation of a query report on
the M2000".
The M2000 does not provide the default function of backing up NodeB traffic
measurement data. Therefore, the export function of the M2000 must be used.
Through the export function, NodeB traffic measurement data is periodically exported
and saved in a file for the Nastar to analyze. The procedure for using the data export
function of the M2000 is as follows:
1) On the M2000 client, choose Maintenance -> Centralized Task Management to
start the centralized task management.
2) Choose Centralized Task Management -> File Interface -> Performance Data Exp
ort, and then double-click Performance Data Export to modify the task attributes.
1) File format: The M2000 can export performance data to a .CSV, .XML, or .TXT fil
e according to the requirement of the background analysis tool. Currently, the Na
star supports the .CSV and .XML file formats.
2) Export period: Set the export period to 5, 15, 30 or 60 minutes, depending on the
requirements. Currently, a NodeB supports these four periods.
If a certain export period is selected but no measurement units related to a NodeB are
found at the bottom of the interface, the adaptation layer of the current NodeB does not
support the export period.
3) Delay: The delay means how long after the data is prepared a request is originat
ed to obtain NodeB data.
4) Directory: The exported NodeB data is saved in the directory set in the attributes
page.
5) After the attributes of the task are modified, start the task. The traffic measureme
nt file of the NodeB is automatically exported to the corresponding directory until t
he task attributes are modified.
The following is an example of a log that records the export of a NodeB traffic
measurement file.
l In the M2000 R6B063SP03, the exported NodeB traffic measurement file supports
two types: one is a file containing all measurement units for each NodeB and the other
is a file containing all NodeBs for each measurement set. These two types can be set
on the M2000. Usually, one file for one measurement set is adopted. How to set the
export of a traffic measurement file according to NEs (namely, a file for a NodeB) is
complicated and therefore a file for a NodeB is not recommended.
l When setting the file export on the M2000, you must set the value of
FileExportMode in the configuration file in the
/export/home/omc/var/etc/pm/tool/PmexpParam.xml directory to 0. Thus, the Nastar
can import the exported NodeB traffic measurement file containing no host name or
NE type name.
4 NodeB OM System
& Note:
l Select a proper software version (English version or Chinese version), consistent with that of
equipment room. Otherwise, different version might lead to reset of RNC and NodeB, and
consequently, version conversion occurs.
l The sequence number is NodeB.
l Select the typical installation mode.
l If the site ID does not exist, you need to add connection with NodeB as below:
Click Office button, and an Office Management dialog box is displayed.
Click Add button, and an Office Information dialog box is displayed.
Type ID or name of the NodeB, type IP address (obtainable from M2000, see 3.12 ),
and click OK to return to Login interface. An interface appears as shown in Figure 4-2.
4) Select ID 20690 in drop-down list or type "20690" directly in Office text box, as
shown in Figure 4-3.
5) Type "NodeB" in Password text box, and click OK to start OM of specified NodeB.
& Note:
In the Office text box, select the ID of specified NodeB by typing it directly or selecting it from the
drop-down menu, and otherwise you start OM of other NodeBs.
l If the site ID does not exist, you need to create a connection with NodeB as below:
Click Office, and the Office Management dialog box appears.
Click Add, and the Office Information dialog box appears.
Type ID or name of the NodeB, type IP address (obtainable from M2000, see 3.12 , or
obtain it by entering LST IPOAPVC in M2000 or corresponding RNC), and click OK to
return to Login interface.
When M2000 fails, you cannot operate any NE through M2000. You can enter LST
IPOAPVC on the corresponding RNC to obtain the IP address of NodeB. An interface
appears as shown in Figure 4-5.
9) Select NodeB from the drop-down menu or type "NodeB" in Office text box, and
then enter NodeB in the Password text box. Then click OK to start OM of a
specified NodeB.
Note:
In the Office text box, select the ID of specified NodeB by typing it directly or selecting it from the
drop-down menu, and otherwise you start OM of other NodeBs. Meanwhile, you must select the correct
NE type (BSC6800 or NodeB) when adding an office direction because all LMTs are integrated into one
LMT in RNCv1.6 and later. You can select the LMT type as required.
If you maintain NodeB using your laptop, you can copy the updated address database
of the NodeB OM console to your laptop. As a result, you do not need to add NodeB
one by one. To achieve this goal, overwrite the UMSCUI file in the installation directory
on your laptop with that in C:\HWLMT\NodeBV100R006\Data on the computer used to
maintain NodeB in the equipment room.
If you start simulated load on a single NodeB, you can start simulated load on a single
NodeB directly or perform it in M2000 OM.
To start simulated load on multiple NodeBs, you can perform batch processing
operations on NodeBs in M2000 to reduce workload. For details, see 3.10.2 .
The command for starting 50% simulated load on a single NodeB is as below:
STR DLSIM: LR=50;
Figure 4-7 shows starting 50% downlink simulated load on NodeB 3812E.
The method for stopping simulated load on NodeB is similar to that of starting simulated
load. If you stop simulated load on a single NodeB, you can directly stop simulated load
on a single NodeB or perform it in M2000 OM.
The command for stopping simulated load on a single NodeB is as below:
STP DLSIM;
The method for querying starting simulated load on a single NodeB is similar to that of
starting simulated load.
The command for querying starting simulated load on a single NodeB is as below:
DSP DLSIM;
& Note:
After HSDPA is introduced, you need to keep the last code word (Ch8, 7) of SF=8 before starting simulated
load on NodeB. Therefore, you need to perform the following operation on RNC first: ADD
RESERVEOVSF: CELLID=1, DLOVSFSF=SF8, DLCODENO=7
The method for stopping simulated load on NodeB is similar to that of starting simulated
load. If you stop simulated load on a single NodeB, you can directly stop simulated load
on a single NodeB or perform it in M2000 OM.
To stop simulated load on multiple NodeBs, you can perform batch processing
operations on NodeBs in M2000 to reduce workload. For details, see 3.10.2 .
The command for stopping simulated load on a single NodeB is as below:
STP DLSIM;
III. Querying simulated load on NodeBv1.7
The method for querying starting simulated load on a single NodeB is similar to that of
starting simulated load.
The command for querying starting simulated load on a single NodeB is as below:
DSP DLSIM;
& Note:
After HSDPA is introduced, you need to keep the last code word (Ch8, 7) of SF=8 before starting simulated
load on NodeB. Therefore, you need to perform the following operation on RNC first: ADD
RESERVEOVSF: CELLID=1, DLOVSFSF=SF8, DLCODENO=7
Before tracing RTWP on specified ID of NodeB, you must start NodeB OM, detailed in
4.1 .
After starting NodeB OM, double click Basic Cabinet icon, and the physical structure
of NodeB is displayed. The physical structure of NodeB 3806/3806A and NodeB 3802C
is different.
When tracing RTWP, pay attention to slot ID of radio frequency (RF) module. The slot
ID is used later for starting RTWP test on different cells of a NodeB.
I. NodeB 3806/3806A
The NodeB 3806/3806A supports 31 (3 sectors, 1 carrier for each sector)
configuration:
l The first cell corresponds to No. 2 NTRX.
l The second cell corresponds to No. 5 NTRX.
l The third cell corresponds to No. 8 NTRX.
Figure 4-13 shows the physical structure of NodeB 3806A.
& Note:
l The physical structure of right part of NodeB3806A cabinet is the same as that of NodeB3806.
l NodeB3806A is an outdoor NodeB, and the left part of it contains power module and storage batteries.
II.NodeB 3812
The NodeB3812 is a high-capacity NodeB of Huawei, supporting 3x4 (3 sectors, 4
carriers for each sector) configuration, and 6x2 (6 sectors, 2 carriers for each sector)
configuration.
The NodeB consists of two symmetric half cabinets, and each half is similar to that of
NodeB3806.
In 6x1 (6 sectors, 1 carrier for each sector) configuration, in the left half cabinet:
l The first cell corresponds to No. 2 NTRX.
l The second cell corresponds to No. 4 NTRX.
l The third cell corresponds to No. 8 NTRX.
In the right half cabinet:
l The fourth cell corresponds to No. 10 NTRX.
l The fifth cell corresponds to No. 14 NTRX.
l The sixth cell corresponds to No. 16 NTRX.
Figure 4-14 shows the physical structure of NodeB 3812.
In Figure 4-16, MAFU is the multi-carrier antenna filtering unit and MTRU is
multi-carrier transmit and receiver unit (including power amplifier).
l The first cell corresponds to No. 0 MTRU.
l The second cell corresponds to No. 2 MTRU.
l The third cell corresponds to No. 4 MTRU
The boards stand for respectively:
l NBBI is the NodeB baseband interface processing unit
l NMPT is the NodeB main processing & timing unit
l NDTI is the NodeB digital trunk interface unit.
I. Procedure
To query cells under NodeB, perform the following steps:
& Note:
l Generally cells under the same NodeB are numbered in sequence. For example, a NodeB has tow
cells, and cell ID of them are 58231 and 58232, as shown in Figure 4-18.
l Some IDs of cells under a NodeB is not displayed in sequence.
& Note:
l Generally cells under the same NodeB are numbered in sequence. For example, a NodeB has two
cells, and cell ID of them are 0 and 1, as shown in Figure 4-18.
l Some IDs of cells under a NodeB is not displayed in sequence.
3) Click Save button, and click OK. Monitoring RTWP of a cell under the NodeB is
started, shown in Figure 4-21.
Figure 4-21 Starting monitoring the second cell under the NodeB
2007-12-13 All rights reserved Page132 , Total220
WCDMA OMC Operation Guide
Internal Open
Query number of cells under the NodeB by executing DSP Cell command. You need
start one RTWP task for each cell. For example, the NodeB has two cells, so you must
start tracing RTWP on the second cell. To use computer resources better, you add a
task for monitoring RTWP in the monitoring window as below:
Right click on RTWP monitoring window, select Add Task item in the displayed menu
to add a task. The file is named and saved following the previous rule, such as
N20690C58232.
Figure 4-22 Saving RTWP file for the second cell under NodeB
& Note:
l You must not trace RTWP of over 40 NodeBs. Tracing RTWP of excessive NodeBs leads to larger
consumption of computer resources. If tracing RTWP of excessive NodeBs last for a long time, the
computer might runs abnormally and loses tracing data.
l In BTS3806/3806A, the NTRX of the second cell corresponds to No. 5 slot, and the NTRX of the third
cell corresponds to No. 8 slot. If you start tracing RTWP of the second cell, change 2 to 5 in Slot No.
text box. If you start tracing RTWP of the third cell, type 8 in Slot No. text box.
l Files are named according to the previous rules so that you can know the Node ID and cell ID.
l You save RTWP data as text files while NodeB save RTWP automatically as MDB files. When you
process RTWP data, you do not need MDB files. Therefore you must delete MDB files saved on the
computer in time to save space after RTWP text files are copied.
The files are saved automatically in the default installation directory, and different types of NodeB and
types. Files for tracing RTWP are saved in different directories according to NodeB types and versions,
such as:
C:\HWLMT\NodeBV100R003\BTS3806V100R003C02B075\Monitor
C:\HWLMT\NodeBV100R003\BTS3802CV100R003C02B075\Monitor
l Due to problems in designing BTS3802C software, during querying some BTSs, parameters of the
second cell are displayed in the first cell, and parameters of the first cell is displayed after parameters
of the second cell.
In Figure 4-23, cell 10042 is displayed first, and then cell 10041 is displayed later. Anyhow you must
trace cell 10041 first.
2007-12-13 All rights reserved Page133 , Total220
WCDMA OMC Operation Guide
Internal Open
l The first cell of BTS3802C corresponds to No. 1 NDRU. The second cell of BTS3802C corresponds to
No. 3 NDRU. Type 3 in NDRU Slot No. text box during RTWP measurement of the second cell, shown
in Figure 4-24.
Figure 4-24 Starting RTWP measurement of the second cell under BTS3802C
Figure 4-27 Saving RTWP file for the second cell under NodeBv1.7
& Note:
NodeBv1.6, NodeBv1.7 and later do not save RTWP as MDB files.
V400R001C02B020 Nastar support importing and analyzing RTWP data. You can start
Nastar, select to import RTWP files to the project. For details, see the guide to using
Nastar.
During querying cell states through RNC, if a cell is abnormal, record the name of the
NodeB related to the cell. Start NodeB OM system to log in to the NodeB. Check the
alarm information about the cell and the historical alarm. The causes to abnormal cell
are as below.
I. Alarms on Transmission
If the system prompts the information shown in Figure 4-28, network connection is
problematic. You can re-log in to BSC6800 OM system, and query E1T1 number of the
NodeB.
Figure 4-29 shows querying E1T1 number by executing LST NodeB command in
BSC6800 OM system.
From previous querying, you can obtain the following information about E1T1:
l Subrack No. = 1
l Bearing slot No. = 0
l Bearing UNI link No. = 22
In BSC6800 OM system, view the E1T1 state by executing the following command:
DSP E1T1: SRN=1, SN=0, PT=WBIE_EPORT, LNKN=22;
Figure 4-30 shows querying E1T1 state in BSC6800 OM system.
From Figure 4-30, you can see "Link running state = Fault", and this means that E1T1 is
in abnormal work state, so you must check the transmission of the NodeB.
II.Other Alarms
Start NodeB OM system, log in to the NodeB. After starting NodeB OM system, and
double click Basic Cabinet icon. The physical structure of NodeB is displayed. The
physical structure of NodeB 3806/3806A and NodeB 3802C is different. You can query
other alarms in two ways.
The first method for querying NodeB alarms is directly querying alarm on NodeB board.
Figure 4-31 shows viewing board states on NodeB3806A.
From Figure 4-32, temperature increase out of range and this leads to automatic
shutdown of NLPA. The causes might be:
l The NodeB is an outdoor cabinet, with air-conditioner. If the NodeB air-conditioner
works abnormally, temperature in the NodeB maybe out of range. This cause is
much probable if alarms exist in three NLPAs.
l The NLPA fan is problematic, and this leads to temperature out of range in part of
NLPA.
2007-12-13 All rights reserved Page141 , Total220
WCDMA OMC Operation Guide
Internal Open
Right click on the NPMU, and select Query Active Alarms. The NPMU alarm is
displayed, as shown in Figure 4-33.
From Figure 4-33, you can see alarm content: air-conditioner/heat-exchanger failure
and ambient temperature out of range.
The second method for querying NodeB alarm is querying alarms through alarm
management system. Perform the following steps:
2) Select Query > Query Alarm Log on NodeB Alarm Management System
interface
A Query Alarm Log dialog box is displayed, as shown in Figure 4-35.
3) In Query Alarm Log dialog box, you can configure alarm log
Select And you can
Cleared View historical alarms (alarms are removed)
Not Cleared View historical alarms (alarms still exist)
Data/Time Type time range for querying historical alarms
Return Numbers (11000) Type the number of alarms to be viewed
To query and extract alarm information on NodeBv1.7, perform the following steps:
Start NodeB OM system, log in to the NodeB. After starting NodeB OM system, and
double click Basic Cabinet icon. The physical structure of NodeB is displayed. The
physical structure of NodeB 3812E and NodeB 3802C is different. You can query other
alarms in two ways.
The first method for querying NodeB alarms is directly querying alarm on NodeB board.
If problems exist in NodeB3812E hardware, yellow or red alarms appear on the
corresponding boards.
l Red indicates a critical alarm.
l Yellow indicates a minor alarm.
Figure 4-37 shows viewing board states on NodeB3812E.
Right click on problematic MAFU, and select Query Active Alarms. Current alarms on
the board are displayed, as shown in Figure 4-38.
The second method for querying NodeB alarm is querying alarms through alarm
management system. Perform the following steps:
5) Click icon in NodeB OM system, start Browse Alarm, and query current and
historical alarms on NodeB.
Figure 4-34 shows the current alarms in NodeB alarm management system.
6) Select Fault Management > Query Alarm Log on NodeB Alarm Managemen
t System interface.
A Query Alarm Log dialog box is displayed, as shown in Figure 4-41.
7) In Query Alarm Log dialog box, you can configure an alarm log:
You can save alarm data of NodeB in text files by following steps below:
1) Right click on the selected alarm, and select Save the Selected Alarms
2) Select the directory, type name of the selected in File Name text box
You can also save all alarms in text files by selecting Save all Alarms.
Figure 4-43 shows saving alarm data of NodeB.
4.7.1 Process
The following paragraphs are based on BTS3812E as an example. For the operation
commands, see Table 4-3. After preparations, use the antenna by following the steps
below:
1) Configure an ALD switch to ON state. By default, the ALD power supply switch is
in OFF state. When using an electric antenna and tower mounted amplifier (TMA),
you must configure the ALD power supply switch to ON state and configure an
electricity alarm threshold.
2) Add ALD-related equipment. If you need add electric antennas or TMAs to the
NodeB, you must add ALD-related equipment by configuring NodeB data. The
ALD-related equipment consists of electric antenna supporting AISG protocol
(AISG_RET) and TMA supporting AISG protocol (AISG_TMA). You might not
configure AISG_TAM to the electric antenna system, but you must configure
AISG_RET.
2007-12-13 All rights reserved Page150 , Total220
WCDMA OMC Operation Guide
Internal Open
Table 4-2 lists the operations commands for electric antenna of BTS3812/3806/3806A.
4.7.3 Operation Commands for Electric Antenna of BTS 3812E/A, BBU, and
DBS
Table 4-3 Operation commands for electric antenna of BTS 3812E/A, BBU, and DBS
Command Function Remarks
Step3: Click the Extended Parameters page and set the following parameters:
1) File format: CSV
2) Export period: It is the same as the traffic measurement data period of an RNC.
3) Delay: To avoid too many tasks on the M2000, the output time should be later than
the task start time.
4) Export all NodeB measurement units.
Step4: Apply the preceding configurations.
Data Import
You must import the configuration file of the RNC before importing NodeB traffic
measurement data. Only a local cell ID and a NodeB name exist in the NodeB traffic
measurement data; you must establish the association between the local cell and the
cell ID through the configuration file.
Import the configuration data, and then import the NodeB traffic measurement data as
shown in Figure 2-17. The procedure is the same as that of importing RNC traffic
measurement data. For details, refer to the Nastar Operation Guide.
Data Query
The operations for querying after data import are the same as those for querying the
RNC traffic measurement data. When you select an index query range, however, you
must select the cell level or NodeB level.
Select the query range of the traffic measurement data. All counters of a NodeB exist in
NodeB Measurement and Cell Measurement as shown in Figure 4-48. The
measurement object of the NodeB-level counters is NodeB or Iub; the measurement
object of the cell-level counters is cell.
For the NodeB-level traffic measurement, select NodeB, as shown in Figure 4-49.
If you want to query the local-cell-level traffic measurement, select Cell Measurement
and traffic measurement counters of NodeB, as shown in Figure 4-51.
The other items, for example, time and query object, are consistent with those for RNC
traffic measurement query. For details, refer to the Nastar Operation Guide.
The query results are shown in Figure 4-52.
On the M2000, you can query the alarms of all NodeBs and extract the alarm data. For
details on the related operations, see "Querying Related Alarms on the M2000".
On the M2000, you can set different query conditions to query the current fault alarms,
event alarms, history alarms, and screened alarms. You can also configure the
common query conditions in an alarm query template to facilitate alarm query.
By setting multiple query conditions, you can quickly find the current fault alarms.
1) Choose Monitor > Query > Current Fault Alarms or click the shortcut icon
in the toolbar.
2) In the Alarm Browse and Query Statistics window, click the Current Fault
Alarm Query tab and set the alarm query conditions.
3) Click Query. The query results are displayed in the result pane under the tab.
l Click Save to save the results in a file. The file can be in the *.txt, *.html, or *.csv format.
l Click Print to print the query results.
l The M2000 automatically names the opened tabs as Current Fault Alarm Query 1, Current Fault
Alarm Query 2, and Current Fault Alarm Query 3 in sequence.
l The maximum number of Browse Alarms tabs, Query Alarms tabs, and Manual Statistics of
Alarms tabs that can be opened in the Alarm Browse and Query Statistics window is nine.
To Select Then
Trace subscribers in local Type IMSI number of the subscriber, perform related calls, and trace
IMSI
network at interfaces
Trace subscribers in local Type subscriber MS number, perform related calls, and trace at
MSISDN
network interfaces
Type subscriber MS number or fixed phone number, perform related
Trace subscribers in other
PSTN calls, and trace messages between the local network and other
network
networks at interfaces (seldom used).
4) Select one or more interfaces in Combination option, and click Auto Save to File
to save result as a file. Select all for ordinary users.
3) Click Final Bill > Normal, locate the data for generating the bill, and double click
the date All bills imported on the day are displayed in the right window.
For example, if you view bill for 21 Feb, 2005, as shown in Figure 5-2, bills
imported by hours are displayed on the right window.
2007-12-13 All rights reserved Page160 , Total220
WCDMA OMC Operation Guide
Internal Open
The system saves bills automatically. Extract bills on the iGWB server. The default
directory for saving bills is E:\backsave\second\x3km\normal. You can extract and view
bills as required.
By setting different query conditions, you can quickly find the event alarms you are
concerned about.
1) Choose Monitor > Query > Event Alarms or click the shortcut icon in the
toolbar.
2) In the Alarm Browse and Query Statistics window, click the Event Alarm Query
tab and set the alarm query conditions.
3) Click Query. The query results are displayed in the result pane under the tab.
l Click Save to save the results in a file. The file can be in the *.txt, *.html, or *.csv format.
l Click Print to print the query results.
l The M2000 automatically names the opened tabs as Event Alarm Query 1, Event Alarm Query 2,
and Event Alarm Query 3 in sequence.
l The maximum number of Browse Alarms tabs, Query Alarms tabs, and Manual Statistics of
Alarms tabs that can be opened in the Alarm Browse and Query Statistics window is nine.
By setting different query conditions, you can quickly find the history fault alarms you
are concerned about.
1) Choose Monitor > Query > History Fault Alarms.
2) In the Alarm Browse and Query Statistics window, click the History Fault
Alarm Query tab and set the alarm query conditions.
3) Click Query. The query results are displayed in the result pane under the tab.
l Click Save to save the results in a file. The file can be in the *.txt, *.html, or *.csv format.
l Click Print to print the query results.
l The M2000 automatically names the opened tabs as History Fault Alarm Query 1, History Fault
Alarm Query 2, and History Fault Alarm Query 3 in sequence.
l The maximum number of Browse Alarms tabs, Query Alarms tabs, and Manual Statistics of
Alarms tabs that can be opened in the Alarm Browse and Query Statistics window is nine.
By setting different query conditions, you can quickly find the screened alarms you are
concerned about.
1) Choose Monitor > Query > Screened Alarms.
2) In the Alarm Browse and Query Statistics window, click the Screened Alarm
Query tab and set the alarm query conditions.
3) Click Query. The query results are displayed in the result pane under the tab.
l Click Save to save the results in a file. The file can be in the *.txt, *.html, or *.csv format.
l Click Print to print the query results.
l The M2000 automatically names the opened tabs as Screened Alarm Query 1, Screened Alarm
Query 2, and Screened Alarm Query 3 in sequence.
l The maximum number of Browse Alarms tabs, Query Alarms tabs, and Manual Statistics of
Alarms tabs that can be opened in the Alarm Browse and Query Statistics window is nine.
You can save the common alarm query conditions in an alarm query template. When
the same query conditions are used, you can use the template to query alarms, without
the necessity of setting query conditions.
l The number of templates that can be automatically loaded must not exceed five.
l Click or in the Alarm Browse and Query Statistics window to display or hide
the template tree.
l In the template tree, the default icon for a template is , the icon for the default
template is , and the icon for an automatically loaded template is .When a
template is both the default template and the automatically loaded template, the
icon is .
1) Choose Monitor > Query. Select the type of alarms, and set the alarm query
conditions in the Alarm Browse and Query Statistics window.
2) Click Template and select Save the current conditions as a template.
3) In the Please enter a template name dialog box, enter the template name. You
can determine whether to set the current template to an automatically loaded
template or the default template according to the requirements.
4) Click OK.
If you need query state of multiple cells, you must query the state respectively. During
network optimization, regional engineers must pay attention to cell states in their areas.
Cell state tables are sent to all in the project team.
For details, see 6.1 .
8 Parameter Comparison
This section describes the parameter script acquisition and specific parameter
comparison method in detail, and presents the concerns in network planning during
parameter comparison. Parameter comparison involves two parts: RNC parameter
comparison implemented by the Nastar R2 and NodeB parameter comparison
implemented by the CME. For details on the NodeB parameter comparison
implemented by the CME, refer to the documents related to the CME. The RNC
parameter comparison implemented by the Nastar is still in the planning stage.
The RNC baseline script can be obtained from the data package of the RNC upgrade
guide at http://support.huawei.com. Usually, the data package contains the file name of
the baseline script. For example, the RNC baseline script is contained in the last page
of 08-Appendix1-5 Description of the Modification to BSC6810 V200R009C01B061
Parameters and External MML Commands.doc. The figure below shows how to obtain
a document containing the baseline script from the website http://support.huawei.com.
Figure 8-1 Obtaining the RNC baseline script from the website http://support.huawei.com
The RNC version is taken an example to illustrate how to obtain the RNC baseline script from the website
http://support.huawei.com. No product baseline is available for the versions earlier than V18071 on the
website. A product baseline is released for related versions later than V18081 on the website. If a project
requires the baseline script of a version earlier than V18071, contact the regional owner for assistance.
8.1.2 Method of Obtaining the RNC MML Script of the existing network
If an M2000 is configured in the network, you can obtain the MML scripts in batches through the M2000 in
the following manner: The MML script in the recent period (this period varies with projects) exists on the
M2000, usually in the /export/home/sysm/Nastar/RNCXXX/CFGMML directory. After logging in to the
VPN, you can log in to the M2000 through the FTP Cute software and download the MML script. If the
system automatically deletes the required MML script because its storage duration exceeds the time limit,
you can telnet the BAM to obtain the script. Data is usually saved on the BAM for more than seven days
(this period may be different, depending on the actual condition).
corresponding parameters in the CME and select the corresponding NodeB parameter
configuration template to export the NodeB baseline XML script. For details on the
specific operations, see Appendix 13 Method of Obtaining the NodeB Baseline Through the
CME.
2) Obtain the NodeB baseline script from the website http://support.huawei.com.
Since the version V18063, a NodeB parameter configuration baseline script is released
together with a new NodeB version. You can obtain the NodeB baseline script from the
website http://support.huawei.com. The baseline is presented in the Excel format. For
example, a file named WCDMA NodeB Release Notes (DBS3800 V100R008C01B063). doc
is obtained from the website, as shown in the figure below.
You can obtain the parameter configuration scripts of the other Nodes in batches
through the M2000 in the following manner:
1) Select multiple NodeBs on the M2000 and perform an NE data backup operation.
After the backup is successful, you can view these files (stored in the M2000
server) in the backup file list.
2) On the backup interface, select the required file list and click Download to Client.
The local client can obtain the XML files of NodeBs in batches.
The figure below shows the detailed operation method.
Figure 8-4 Obtaining NodeB parameter configuration scripts in batches through the M2000
The Nastar R2 requires the support of two types of software, namely, .NET
Framework2.0 and SQL Server2005. Install the SQL Server2005 server version if the
Nastar R2 is a server version; install the SQL Server2005 Express version if the Nastar
R2 is a stand-alone version. The following takes the stand-alone version as an example
to describe the software installation. Install .NET Framework2.0 and SQL Server2005
Express in sequence.
1) Install NET Framework2.0. For details about the installation method, see Appendix
6 .NET Framework2.0 Program Installation Method
2) Install the SQL Server2005 Express. For details about the installation method, see
Appendix 7 SQL Server2005 Express Program Installation Method.
After installing the SQL Server2005 Express, check the running of the SQL Server2005
Express. Choose Start -> All Programs -> Microsoft SQL Server 2005 ->
Configuration Tools -> SQL Server Configuration Manager to open the SQL server
configuration manager. Ensure that the SQL server and the SQL server browser work
normally, as shown in the figure below. If the start mode is set to Automatic, the system
automatically runs the SQL Server2005 Express at next boot.
Open the login interface of the Nastar R2, as shown in the figure below.
By default, the username is sa and the login password is the one entered when the
SQL Server2005 Express is installed. Note: If you select Mixed Mode during the
2007-12-13 All rights reserved Page174 , Total220
WCDMA OMC Operation Guide
Internal Open
installation of the SQL Server2005 Express, the program prompts for a password. This
password is only the login password. You should pay special attention to the options of
the SQL Server2005 Express during the installation, as shown in the figure below.
Selection of the SQL server. If the SQL server is used as the default server in the SQL
Server2005Express installation, the server name is SQL Express. If you have changed
the server instance, log in to the server as the instance you have installed. The
username used to log in to the default SQL server is (local)\SQLExpress. If a server
instance is created, the login username is (local)\XXX. Here XXX is the created server
instance.
Here the personal domain account can be substituted for (local), but the following cases should be
distinguished: If the network is connected through the domain account and the domain account is
displayed during the installation of the SQL Server2005 Express, you can use domain account + \ +
server instance as the server name to log in to the SQL server. Otherwise, you fail to log in to the SQL
server in this mode. It is common to use (local) + \ + server instance as the server name to log in to the
SQL server.
The comparison with the baseline parameters is used to compare the existing network
parameters with the product baseline and find out the differences between the
2007-12-13 All rights reserved Page175 , Total220
WCDMA OMC Operation Guide
Internal Open
Figure 8-9 File configuration for comparison with the baseline parameters
Compare mode: Option for hierarchical networking. If the hierarchical networking does not apply, set the
option to one base cell.
Baseline file: Baseline.
Base cell ID: Reference cell ID.
The parameter comparison between different cells in one MML script is used to check
the parameter configurations between different cells in one RNC for inconsistency. The
reference cell is a specified cell in the existing network. The specific operation method
is as follows:
Open the Nastar and select the Trouble Shooting view and the Compare
Configuration with Baseline option.
Figure 8-10 Parameter comparison between different cells in one MML script
Figure 8-11 File configuration for parameter comparison between different cells in one MML script
The parameter comparison between different RNCs is used to compare the parameter
scripts between two RNCs in the existing network and check the parameter
configurations in the whole network for inconsistency. The specific operation method is
as follows:
Open the Nastar and select the Trouble Shooting view and the Compare
Configuration with Baseline option.
Figure 8-12 (RNC-level and cell-level) parameter comparison between different RNCs
the reference RNC is imported to the Nastar as the baseline MML script, as shown in
the figure below.
The preceding figure shows a case of hierarchical networking. In this case, the
parameters of R99 cells and H cells at the radio layer differ greatly. Therefore, R99 cells
and H cells should be distinguished during parameter comparison.
Double-click MML File Compare. The main interface for parameter comparison
between different versions of an RNC is displayed, as shown in the figure below.
Figure 8-15 Parameter configuration for parameter comparison between different versions of an RNC
If the MML script to be compared is imported to the Nastar through TransData, you can select Project for
the MML file from option; if the MML script to be compared needs to be imported on site, you can select
Disk for the MML file from option.
For the Cell option, you can select the required cells from the cells in the MML script to be compared to
improve the comparison efficiency.
For the Command option, you can select certain parameter commands in the configuration file to improve
the comparison efficiency.
You can select the cells and commands to be compared from the Cell and Command
options. You must configure these options in the XML script (namely, RNC parameter
configuration file) in advance. For details, see Appendix 2 Configuration File for the
Nastar Parameter Comparison Tool.
9 Appendix
List of BSC6800
MML Batch Processing Commands
I. Introduction to OCNS
The protocol 25.101 defines OCNS as follow:
OCNS is the necessary power so that total transmit power spectral density of NodeB
(lor) adds to one.
& Note:
For dynamic power correction required to compensate for the presence of transient channels, e.g. control
channels, a subset of the DPCH channels may be used.
Set up a fictitious load under NodeB so that the transmit power of the local cell reaches
100%. Namely, the total power of tested link and fake line is the downlink total power of
the cell. If the traffic measurement of tested link is adjustable (the downlink power
control is enabled), then the transmit power of other links must be adjusted so that the
total power of all links is the total power of the cell. The following section provides the
major parameters of 16 fake links when the power of tested link is fixed in the protocol.
2007-12-13 All rights reserved Page183 , Total220
WCDMA OMC Operation Guide
Internal Open
II. DPCH Spreading Code, Timing Offsets, and Relative Level Settings for OCNS
Signal
Table 9-1 lists the DPCH spreading code, timing offsets, and relative level settings for
OCNS signal.
Table 9-1 DPCH spreading code, timing offsets, and relative level settings for OCNS signal
Channelization code Timing offset (x256Tchip) Level setting (dB)
2 86 1
11 134 3
17 52 3
23 45 5
31 143 2
38 112 4
47 59 8
55 23 7
62 1 4
69 88 6
78 30 5
85 18 9
94 30 10
125 61 8
113 128 6
119 143 0
P-TMSI, or IMEI) and selecting the standard interface, you can trace the single
subscriber signaling messages at standard interfaces. You can obtain UE IMSI by
consulting the customer service center of the carrier or querying it from HLR. In
addition, you can confirm IMSI by RANAP COMMON ID message. TMSI and
P-TMSI change after TMSI relocation. If you need trace them, you can obtain them
from RRC CONN REQUEST message. After UE reset and expiration of TMSI
reconfiguration timer, TMSI or P-TMSI change. Therefore you must retrace them.
You can obtain IMEI from UE vendor. You can trace emergency subscriber without
SIM module by it. In case of RAB assignment failure, RAB release failure, paging
failure, lu release failure, safety mode control failure, initial UE message failure,
and transition failure, you can locate the obstacle and solve the problem by
analyzing messages at lu interface. In case of radio link setup failure, radio link
adding failure, radio link removal, common transmission channel resource release
failure, downlink power control failure, and paging failure, you can locate the
obstacle and solve the problem by analyzing messages at lub or lur interface. In
case of RRC connection setup failure, RB setup failure, PCH reallocation failure,
and cell update failure, you can locate the obstacle and solve the problem by
analyzing messages at Uu interface. The lu interface messages (RANAP protocol
messages) and lur interface messages (RANSAP protocol message) of the task
UE tracing (standard interface messages) are connection-oriented messages, not
non-connection messages. The lub interface messages (NBAP protocol message)
of the task UE tracing (standard interface messages) are dedicated NBAP
messages, but not common NBAP messages. If you trace single subscriber by
using IMSI, and the RRC CONNECT REQUEST message includes the consistent
IMSI when UE is accessing the network, you can trace the single subscriber by
tracing messages after RRC CONN REQUEST message. If you trace single
subscriber by using IMSI, the RANAP COMMON ID message, but not RRC
CONNECT REQUEST, include the IMSI when UE is accessing the network, you
can trace the single subscriber by tracing messages after RANAP COMMON ID
message. The messages before RANAP COMMON ID message are dropped.
The index USER on the traced result displayed in the UE Tracing (Standard
Interface Messages) task view window means differently to different interfaces.
For lu and lur interface messages, USER is DPC ID. For lub interface messages,
USER is NodeB ID. For Uu interface messages, USER is invalid (oxFFFFFFFF).
On the message view window, right click. In the displayed menu, you can select
Board Response List, and can view all WSPU information of unreceived
response messages and received response messages.
2) Tracing single subscriber signaling messages at subscriber and signaling plane
The messages are at signaling and user plane at standard interfaces related to
specific tracing event during calling by specified UE. You can type the UE identity
(IMSI, TMSI, P-TMSI, or IMEI) and select the specific events. Tracing this type of
messages has something in common with the task UE tracing (standard interface
messages): the messages to be traced are related and triggered in tracing
specified UE in calling. Yet they are different. The task UE tracing (standard
interface messages) involves signaling messages at four standard interfaces. The
task UE tracing (subscriber and signaling plane) involves standard messages at
signaling plane, self-defined information at signaling plane, and reported data at
user plane. It divides the traced messages according to report information content.
Namely, you can select different traced messages by selecting different events.
The task UE tracing (subscriber and signaling plane) involves much information,
which impacts system operation. Therefore, reduce the traced events as possible.
The RNC can trace 6 UEs at most. If the task UE tracing (standard interface
messages) can meet the requirements, use this task as possible.
3) IOS tracing. IOS tracing is tracing all subscribers meeting default conditions. By
IOS tracing, you continuously traced the calls of specified number (the number is
specified at beginning of the task) which access the network in specified cell. The
content to be traced is the messages generated during calling. Select the types of
traced messages by selecting traced events. Only the subscribers access the cell
by RRC or migrate (including inter-system handover) to the cell. Stopping tracing
is triggered when RRC is released or the subscribers migrate out of the cell.
Type the number of continuous calls to be traced, sampling standard, and tracing
time. The sampling standard is defined according to RAB parameter restriction.
The RAB parameter restriction is valid only when tracing a new call starts. If a call
meets the sampling standard, the call keeps being traced despite that the RAB
parameters are modified after starting the call. If the RAB parameters does not
meet sampling standard at the beginning but meet sampling standard after
modification, the call will not be traced. The task IOS tracing involves much
information, which impacts system operation. The index of the upper limit of
number of calls traced simultaneously must be smaller than 6. Tracing all events at
a time is not recommended. In addition, use the task as less frequently as
possible.
II. Tracing Cell Signaling Messages
Tracing cell signaling messages is tracing NBAP common messages or
USER_VOLUMN events in specified cells. The USER_VOLUMN events include
self-defined messages, reflecting statistics information of UE in the cell. Specify the cell
by typing cell ID. Select the type of messages to be traced by selecting traced events.
The cells to be traced must be activated first.
The task cell tracing involves much information, which impacts system operation. The
system supports tracing 32 cells at most simultaneously. If lub interface tracing meets
requirements, use it as possible.
III. Tracing Signaling Messages at Standard Interfaces
The interfaces include Uu, lub, lur, and lu interface. When the subscribers are in a large
number, the signaling to be traced at standard interfaces is much. This impacts system
operation. Solve the problem by using testability log and tracing single subscriber.
1) Tracing Uu interface messages.
This traces all or partial signaling messages at Uu interface in the selected cell. The
USER displayed in the traced result on the message view window is the cell that tr
ansmits or receives the message.
2) Tracing lub interface messages.
This traces standard messages at lub interface, including NBAP dedicated
messages and common messages. The USER displayed in the traced result on the
task message view window is the opposite NodeB ID. The NodeB ID is queried by
executing LST NODEB command. The NCP and CCP port number are queried by
executing LST IUBP command.
3) Tracing lur interface messages.
This traces standard messages at lur interface, including connection-oriented and
non-connection messages. The USER in the traced result displayed task message
view window is the DPC ID of opposite RNC. Query DPC ID by executing LST
N7DPC command.
4) Tracing lu interface messages
This traces standard messages at lu interface, including connection-oriented and
non-connection messages. The USER in the traced result displayed task message
view window is the DPC ID of opposite CN. Query DPC ID by executing LST
N7DPC command.
IV. Signaling Messages in Protocol of Transport Network Layer
The messages include QAAL2, SCCP, MTP3B, and SAAL protocol messages. Tracing
these messages helps analyze failure at interface link.
In case of RAB assignment failure, RRC setup failure, and cell setup failure, you can
locate the obstacle and solve the problem by tracing QAAL2 protocol messages. When
the CN side cannot receive direct transmission messages and the RNC cannot receive
paging messages sent by CN:
l If the target signaling point is reachable, you can locate the obstacle and solve the
problem by tracing SCCP protocol messages.
l If the target signaling point is unreachable or MTP3B link is unavailable, you can
locate the obstacle and solve the problem by tracing MTP3B protocol messages.
l If the SAAL link is unavailable, you can locate the obstacle and solve the problem
by tracing SAAL protocol messages.
the task stops. If the monitored connection returns from CCH to DCH, the task
restarts. The monitored data is submitted in a NodeB-specific measurement
report periodically.
4) SIR target value of uplink radio link set
By monitoring it, you can obtain realtime state of SIR quality target value required
by radio link set connected on DCH. It reflects requirements on uplink radio link
quality and variation of requirements. The monitored data is reported inside RNC
periodically.
5) Measured SIR error of uplink radio link set
By monitoring it, you can obtain realtime state of measured SIR error of radio link
set connected on DCH. In addition, you can observe whether the radio link set
SIR matches the variation of SIR target value and can evaluate function of uplink
inner loop power control. If the measured SIR error of uplink radio link set change
s all the time but remains convergent to 0 dB, the uplink inner loop power control
is convergent. Otherwise, the uplink inner loop power control is divergent. The
monitored data is reported inside RNC periodically.
6) Uplink transport channel BLER
By monitoring it, you can monitor the BLER variation of the signaling transport
channel and major service transport channels connected to DCH. It helps
analyze uplink radio link quality. If the uplink transport channel BLER increases,
the uplink radio link quality declines. Otherwise, the uplink radio link quality
increases. If the uplink radio link BLER keeps great, especially with an over great
BLER of signaling transport channel, the uplink link quality is over poor. This
might cause uplink asynchronization which consequently causes release of entire
connection. The monitored data is submitted in a NodeB-specific measurement
period report.
7) Downlink code transmit power
By monitoring it, you can obtain the variation of code transmit power of each
downlink radio link connected on DCH. It reflects the number variation of radio
links involved in the current connection. In addition, it helps analyze downlink
power consumption. If the measured downlink code transmit power increases,
even approaching the maximum downlink code transmit power configured in
signaling messages, the downlink radio link quality declines. The monitored data
is submitted in NodeB-specific measurement period report.
8) UE transmit power
By monitoring it, you can obtain the realtime variation of uplink UE transmit power
on DCH. It helps analyze uplink radio link quality. If the UE transmit power keeps
increasing, even approaching the upper limit to UE capacity, the uplink radio link
quality declines. The monitored data is reported at Uu interface periodically.
9) Uplink PCH BER
By monitoring it, you can obtain the realtime variation of uplink physical channel
(PCH) BER connected DCH. It helps analyze uplink radio link quality. If the uplink
PCH BER increases, the uplink radio link quality declines. Otherwise the uplink
radio link quality increases. If the uplink PCH BER keeps high, the uplink quality
is poor. This causes uplink asynchronization, which consequently causes release
of entire connection. The monitored data is reported inside RNC periodically.
10) Uplink traffic
By monitoring it, you can obtain the realtime variation of uplink traffic (cache data
amount at UE side) of PS interactive or background services. It helps analyze tra
nsmission performance of uplink traffic. If the uplink traffic keeps approximately e
increases the data flow between the host device and BAM. Monitoring excessive cells
is not recommended and monitoring period must not be over small. Otherwise the
system performance is affected. Activate the cells before monitoring. Query activated
cells by executing the DSP CELL command. Query parameters of monitored cells by
executing the LST CELL command. Over high system utilization triggers flow control,
and then the system stops inferior tasks and prohibits starting inferior tasks.
1) Transmit power of cell PIPICH pilot
By monitoring it, you can observe and judge whether the pilot power of a specifie
d cell is normal. Query the automatic adjustment range of cell PCPICH pilot powe
r by executing LST PCPICH and cell PCPICH.
2) Received power of cell uplink total bandwidth
By monitoring it, you can the uplink load level of a specified cell. The NodeB mea
sures and reports the uplink total bandwidth received power. You can perform co
mmon measurement on cells to be monitored. Before activation of cell, equipmen
t room operators query by executing the LST CELLALGOSWITCH command an
d ensure the LDM (load monitoring algorithm) of cell algorithm switch is enabled
(modifying the switch by executing the MOD CELLALGOSWITCH command). Aft
er activation of cell, the system constructs the common measurement process, wi
th the COMMON MEASUREMENT REPORTING message at lu interface.
The uplink load factor (the ratio of uplink total bandwidth received power of cell to
cell background noise) measures the cell uplink load in admission process. The c
ell background noise is a constant (setting it by executing the ADD CELLCAC or
MOD CELLCAC command), so the uplink total bandwidth received power of cell
decides relative level of cell uplink load.
3) Transport power of cell downlink carrier
By monitoring it, you can obtain the realtime level of cell downlink load. The Node
B measures and reports transmit power of cell downlink carrier. You can perform
common measurement on the cells to be monitored. Before activation of cell, equ
ipment room operators query by executing the LST CELLALGOSWITCH comma
nd and ensure the LDM (load monitoring algorithm) of cell algorithm switch is ena
bled (modifying the switch by executing the MOD CELLALGOSWITCH comman
d). After activation of cell, the system constructs the common measurement proce
ss, with the COMMON MEASUREMENT REPORTING message at lu interface.
The ratio of downlink carrier transmit power to maximum transmit power of cell m
easures cell downlink load in admission process. Set the maximum transmit powe
r of cell by executing the ADD CELLSETUP command upon cell setup. After cell
setup, modify the maximum transmit power of cell by executing the MOD CELLS
ETUP command.
When HSDPA is used, NodeB can monitor cell carrier power and non-HSDPA carrier
power at the same time. To do so, you need to enable cell measurement on CELLALG
OSWITCH by using the MOD CELLALGOSWITCH: NBMSwitch=HSDPA_MEAS-1 co
mmand.
4) Number of cell CCH subscribers
By monitoring it, you can obtain the realtime number of CCH subscribers in the c
ell.
5) Number of cell DCH subscribers
By monitoring it, you can obtain the realtime number of DCH subscribers in the c
ell.
6) Node synchronization
By monitoring it, you can obtain the time difference between RNC frame number
(RFN) and NodeB Frame Number (BFN), as well as the time for completing node
synchronization. If the difference changes sharply, the transmission between RNC
and NodeB is problematic.
7) Uplink admission judgment
By monitoring it, you can obtain the predicted value of uplink load factor in admis
sion judgment and the variation of measured load factor. Therefore, you can mea
sure the accuracy of uplink admission load. You can perform common measurem
ent on the cells to be monitored. Before activation of cell, equipment room operat
ors query by executing the LST CELLALGOSWITCH command and ensure the
LDM (load monitoring algorithm) of cell algorithm switch is enabled (modifying the
switch by executing the MOD CELLALGOSWITCH command). After activation o
f cell, the system constructs the common measurement process, with the COMM
ON MEASUREMENT REPORTING m essage at l u i nterf ace.
Monitoring uplink admission judgment is effective only when the uplink admission
control algorithm switch is set to load prediction algorithm. Configure the switch
by executing the MOD CELLALGOSWITCH command. Query the switch state b
y executing the LST CELLALGOSWITCH command.
The uplink load factor (the ratio of uplink total bandwidth received power of cell to
cell background noise) measures the cell uplink load in admission process. Confi
gure cell background noise by the ADD CELLCAC or MOD CELLCAC command.
8) Downlink admission judgment monitoring
By monitoring it, you can obtain the predicted value of downlink load factor in ad
mission judgment and the variation of measured load factor. Therefore, you can
measure the accuracy of downlink admission load. You can perform common me
asurement on the cells to be monitored. Before activation of cell, equipment room
operators query by executing the LST CELLALGOSWITCH command and ensur
e the LDM (load monitoring algorithm) of cell algorithm switch is enabled (modifyi
ng the switch by executing the MOD CELLALGOSWITCH command). After activ
ation of cell, the system constructs the common measurement process, with the
CO MMO N MEASUREMENT REPO RT I NG message at l u i nt erf ace.
Monitoring downlink admission judgment is effective only when the downlink admi
ssion control algorithm switch is set to load prediction algorithm. Configure the
switch by executing the MOD CELLALGOSWITCH command. Query the switch
state by ex ecuti ng the LST CELLALGOSWIT CH comm and.
The ratio of downlink carrier transmit power to maximum transmit power of cell m
easures the cell downlink load in admission control process. The maximum trans
mit power of cell is a constant (setting it by executing the ADD CELLSETUP com
mand upon cell setup), so the downlink carrier transmit power of cell decides relat
ive level of cell downlink load.
9) Uplink equivalent subscribers
By monitoring normalized factor of uplink total services in the specified cell, you c
an obtain the variation of uplink equivalent subscribers based on cell subscribers
(cell CCH subscribers and cell DCH subscribers). Monitoring uplink equivalent su
bscribers is effective only when the uplink admission control algorithm switch is s
et to total service normalized factor algorithm (configuring it by executing the
MOD CELLALGOSWITCH command and querying it by executing the LST CEL
LALGOSWITCH command). During the admission control process using total ser
vice normalized factor algorithm, select a service and a rate (12.2k AMR voice ser
vice) as a standard service. The normalized factor for a service is the ratio of the
system capacity used by the service to that of the standard service. The normaliz
ed f actors are different for uplink and downlink of the same service.
The normalized factor of cell uplink total service is the sum of all normalized facto
rs of each service. It reflects the uplink load level of cell and increases as the cell
subscriber increase.
10) Downlink equivalent subscribers
By monitoring normalized factor of downlink total services in the specified cell, yo
u can obtain the variation of downlink equivalent subscribers based on cell subscr
ibers (cell CCH subscribers and cell DCH subscribers). Monitoring downlink equi
valent subscribers is effective only when the downlink admission control algorithm
switch is set to total service normalized factor algorithm (configuring it by exe
cuting the MOD CELLALGOSWITCH command and querying it by executing the
LST CELLALGOSWITCH command). During the admission control process usin
g total service normalized factor algorithm, select a service and a rate (12.2k AMR
voice service) as a standard service. The normalized factor for a service is the ra
tio of the system capacity used by the service to that of the standard service. The
normalized factors are different for downlink and downlink of the same service.
The normalized factor of cell downlink total service is the sum of all normalized fa
ctors of each service. It reflects the downlink load level of cell and increases as th
e cell subscriber increase.
11) Cell code tree usage
By monitoring downlink channel orthogonal variable spreading factor (OVSF) cod
e tree, you can obtain the realtime usage of cell downlink channel code. When th
e mouse pointer stops on a code table, the system prompts the spreading factor
of the code, code number, and state.
12) Minimum power requirements on HS-DSCH channel
To minimize the bit rate for HSDPA subscribers, you can reserve part of the powe
r for HS-DSCH. You can perform real-time monitoring using this item.
13) Bit rate provided by HS-DSCH
This performance varies with subscriber bit rates in real time.
CDT tracing is similar to CDL tracing. It combines signaling tracing with L2 user plane
information. To trace CDT, perform the following steps:
Select Service > Trace Management > Interface Trace Task, and then enter the IMSI
number of the UE.
Because there is a lot to be traced, you should trace fewer than two subscribers on th
e same computer. The file is saved at C:\HWLMT\BSC6800V100R005ENG\BSC6800
V100R005ENGC01B068\Trace by default.
& Note:
Like RNCv1.5 OM, RNCv1.6 LMT also provides CDRs.
Use 0 or 1 to disable or enable this feature.
By default, the function of viewing CDT is disabled. To view the information on the user
plane, you must change value in the file.
& Note:
You must back up the RncTestConfig file in advance. When you use Trace viewer, you find that the
RncTestConfig file contains all information on both signaling plane and user plane. If you need to view
information only on the signaling plane, you do not need to change configuration according to the
above-mentioned procedure.
For V16C01B082, V17C01B030 and later, Insight Plus is integrated into LMT. After
installing RNC LMT, you need to configure the configuration file manually and enable
debugging to switch to the interval version. Then you can view the collected CHR file
through Insight Plus.
To change the configuration file, perform the following steps:
1) Open the configuration file InsightPlus.ini. By default, this file is saved at $:\HW
LMT\adaptor\clientadaptor\BSC6800\BSC6800V100R006C01B082\Insight
Plus\chs\data\.
2) Change the value of VersionType: VersionType=InsightPlus
Internal version:
[System]
HelpFile=InsightPlus.chm
VersionType=InsightPlus
StaticTree=FALSE
HideTreeNumber=FALSE
RecordAllLog=FALSE
LogNumberPerPage=2000
LogFileTypeList=log, log file|
CodeExplainShowSingleLine=FALSE
CodeExplainSelectFirstLine=FALSE
3) Open the Insight tool again. You can view the internal information, such as project
tree.
Parameter configuration is the key to the MML script comparison function. The
parameter configuration, parameters to be compared, and parameter display are an
integrity. The parameters that the Nastar compares must be preset in the parameter
configuration template. The Nastar does not compare those parameters that are not
preset. Only the parameters with different comparison results are displayed. The
configuration file directory (add instance description) is WCDMA\TEMPLATE
FILES\WCDMA\ConfigurationCommand. There are three XML script files in the
2007-12-13 All rights reserved Page195 , Total220
WCDMA OMC Operation Guide
Internal Open
cmdtype.xml
The cmdtype.xml file is used for parameter classification. The parameter format is
shown in the figure below.
You can obtain the required parameter by performing configurations shown in the
preceding figure. For example, RNC parameters are divided into air interface
parameters and parameters oriented to the transport layer of NodeB. The parameter
configuration in the file is used by the R&D personnel for program implementation.
Therefore, the network planning personnel do not need to pay special attention.
cmpcmd.xml
The cmpcmd.xml file is used for parameter matching. Different commands match
different parameters. Therefore, relevant matching parameters must be configured for
comparison. Otherwise, the comparison results cannot meet the customer's
requirement. The network planning personnel must pay attention to this part of the
parameter configuration. The figure below shows the parameter matching format.
EspecialCommand.xml
The EspecialCommand.xml file is used for the configuration of special command
parameters, for example, switch parameters to be analyzed. The figure below shows
the parameter format.
Configuration method: If you want to neglect the CELLID parameter, the configuration
command is as follows:
<Cfgindex Param="CELLID" Value="0" Match="0"/> The item to be neglected is
configured in the cmpcmd.xml file. Here, the value 0 of Match indicates that the parameter
is not compared; the value 0 of Value indicates that the parameter is not displayed.
CELLID is the neglected parameter and is not processed.
2) Contradiction between parameter matching and parameter mismatching
When the parameters of different RNCs are compared, certain RNC-level parameters
(including some cell-level parameters) such as RNCID and CELLID do not need to be
compared. When the parameters of one RNC before and after an upgrade are compared, the
parameters should completely match. Thus, a contradiction between parameter matching
and parameter mismatching occurs. Currently, one parameter configuration script cannot
satisfy the requirements of two types of parameter comparison. The current solution is to
add another parameter configuration script in the next version so that the requirements of
the two types of parameter comparison can be satisfied.
3) Problem about the comprehensiveness of parameters
As the transport layer parameters cannot be compared, the problem about the
comprehensiveness of parameters arises. The existence of parameter configuration items
for Nastar's parameter configuration gives us such a hint: When configuring parameters,
we can add or delete some parameters to meet different requirements. Before the parameter
comparison module is widely applied, the parameter configuration must be reviewed and a
reference parameter configuration script is required. Some parameters cannot be compared.
This results in a contradiction between parameter display and parameter comparison
comprehensiveness. Therefore, parameter configuration is more crucial.
At present, there is no accurate method for comparing the transport layer parameters. Therefore, these
parameters are directly neglected. In addition, some parameters are not configured because they are
insignificant. Therefore, you should distinguish the problem about the comprehensiveness of parameter
comparison all by yourself.
It is confirmed that the parameters that have been compared and that have not been compared are listed.
You can configure the parameters that are not configured in the parameter configuration script according
to requirements. The program is unable to distinguish new parameters from those that are not configured
(for example, transport layer parameters). This function is implemented in the version released on January
2008.
cmpcmd.xml
cfg.rar
Para Command
SET MACHSPARA HSDPAPARA_V18 SCCHPWR SCCHPWR
SET MACHSPARA HSDPAPARA_V18 SCCHFER SCCHFER
SET MACHSPARA HSDPAPARA_V18 IBLER INITBLER
SET MACHSPARA HSDPAPARA_V18 RSCLMSW RSCLMTINGSW
SET MACHSPARA HSDPAPARA_V18 DYNCODESW DYNCODESW
SET MACHSPARA HSDPAPARA_V18 16QAMSW SIXTEENQAMSW
SET MACHSPARA HSDPAPARA_V18 ADJCOEOFPF ADJCOEOFPF
SET MACHSPARA HSDPAPARA_V18 MXPWRPHUSR MXPWRPHUSR
SET MACHSPARA HSDPAPARA_V18 CQIFA CQIFILTERALPHA
SET MACHSSPIPARA HSDPASPIPARA SPIGBR SPIGBR
SET MACHSSPIPARA HSDPASPIPARA SPIWEIGHT SPIWEIGHT
SET MACHSSPIPARA HSDPASPIPARA SPIRSCRATIO SPIRSCRATIO
SET MACEPARA HSUPAMACEPARA AGTHRESHOLD AGTHRESHOLD
SET MACEPARA HSUPAMACEPARA WSPI WSPI
SET MACEPARA HSUPAMACEPARA CELLNOISEFUNDUS CELLNOISEFUNDUS
SET MACEPARA HSUPAMACEPARA GBRSWITCH GBRSWITCH
SET MACEPARA HSUPAMACEPARA EAGCHPCMOD HPCMODE
SET MACEPARA HSUPAMACEPARA EAGCHPWROFFSET HPCPWROFFSET
SET MACEPARA HSUPAMACEPARA EAGCHPOWER HPCFIXPWR
SET MACEPARA HSUPAMACEPARA SERGCHPCMOD HPCMODE
SET MACEPARA HSUPAMACEPARA SERGCHPWROFFSET HPCPWROFFSET
SET MACEPARA HSUPAMACEPARA SERGCHPOWER HPCFIXPWR
SET MACEPARA HSUPAMACEPARA NSERGCHPCMOD HPCMODE
SET MACEPARA HSUPAMACEPARA NSERGCHPWROFFSET HPCPWROFFSET
SET MACEPARA HSUPAMACEPARA NSERGCHPOWER HPCFIXPWR
SET MACEPARA HSUPAMACEPARA SEHICHPCMOD HPCMODE
SET MACEPARA HSUPAMACEPARA SEHICHPWROFFSET HPCPWROFFSET
SET MACEPARA HSUPAMACEPARA SEHICHPOWER HPCFIXPWR
SET MACEPARA HSUPAMACEPARA NSEHICHPCMOD HPCMODE
SET MACEPARA HSUPAMACEPARA NSEHICHPWROFFSET HPCPWROFFSET
SET MACEPARA HSUPAMACEPARA NSEHICHPOWER HPCFIXPWR
SET MACEPARA HSUPAMACEPARA BUFCONGTHD BUFCONGTHD
SET MACEPARA HSUPAMACEPARA BUFCONGTHDHYS BUFCONGTHDHYS
SET MACEPARA HSUPAMACEPARA RNCFLUXENABLE RNCFLUXENABLE
SET SMTHPWRSWTCH SMTHPWRSWTCH SWITCH SWITCH
SET CLSPATIMER CLOSEPATIME LOWERLIMIT LOWERLIMIT
SET CLSPATIMER CLOSEPATIME UPPERLIMIT UPPERLIMIT
SET RESALLOCRULE DLRESALLOCRULE RULE RULE
2007-12-13 All rights reserved Page200 , Total220
WCDMA OMC Operation Guide
Internal Open
Para Command
ADD SEC SECTOR_V18 SECT SECTORTYPE
ADD SEC SECTOR_V18 DIVM DIVMODE
ADD LOCELL LOCALCELL_V18 RADIUS RADIUS
ADD LOCELL LOCALCELL_V18 HORAD HORAD
ADD LOCELL LOCALCELL_V18 DEFPWRLVL DEFPWRLVL
ADD LOCELL LOCALCELL_V18 DLRESMODE DLRESALLOCMODE
ADD LOCELL LOCALCELL_V18 DI ULNI
ADD LOCELL LOCALCELL_V18 HISPM HISPM
NODEBSOM NODEBSOM NODEBSRCID NODEBSRCID
LOCALCELL_V18 LOCALCELL_V18 LOCELLID LOCELLID
The first column lists the parameter commands of the NodeB LMT. The second column is the mapping of
the command parameters of the NodeB LMT in the XML script. The third column is the specific parameters
in the commands of the NodeB LMT. The fourth column is the mapping of the parameters in the XML script.
The parameter table is the parameter mapping table, namely, the parameter configuration script.
For easy program implementation, two parameters are added: NODEBSCRID and LOCELLID. In this way,
after NodeB parameters are obtained in batches, these two parameters can distinguish Node Bs from
cells.
The parameters highlighted in colors in the table are SPI parameters and MAC-E parameters. You should
pay attention to these two parts of parameters.
Use the program installation path as the default installation path. Otherwise, the Nastar
cannot be opened.
You must select the Mixed Mode option, and then enter the password. The default
username used to log in to the Nastar is sa.
After configuring the CME server information, you can log in to the CME server and
open the CME operation interface.
Enter the RNC ID, and select an RNC version and NodeB version.
As we are concerned only with the radio parameters in the corresponding NodeB version during network
planning, the negotiation planning data and the RNC-level parameters are not configured. After the
parameters of a cell are configured, the parameter configuration script of the NodeB is exported. The
parameter configuration script is only the NodeB baseline script that should be given importance in
network planning. The radio layer parameters configured on the NodeB are the parameters in the default
NodeB version. Therefore, the NodeB version here must be the one that the customer requires. After the
parameter configuration, the corresponding parameters of the selected NodeB version are stored in the
exported XML script.
In this case, the network planning personnel must configure one cell for each NodeB, but need not
configure any negotiation data (including transport layer parameters and neighborhood) because only the
default configuration items at the radio layer are considered important.
On this interface, you can click the MML button to export the RNC MML baseline script directly. You can
directly obtain the RNC baseline script from the website http://support.huawei.com. Therefore, the method
of obtaining MML baseline script through the CME is not recommended. You can also obtain the RNC
baseline script through the CME.
This operation is required because an XML script can be exported only after the physical channel
information is configured.
Here we can see that we can directly import an existing XML script through the CME. After the XML script
is imported using the CME, you can view the related configuration information. It is confirmed that the
NodeB parameter comparison is not implemented in the CME. However, this function is ready to be added
to the CME. The specific implementation time needs to be confirmed and the function is now at the
requirement submission phase. The actual requirement is not discussed with the R&D personnel.
The XML script we eventually see is the NodeB reference parameter configuration
script that we concern.
It is confirmed that the reasons for the parameter differences in the parameter change record are as
follows:
Report_
.rar
Cluster-To-Cell indicates the cell group to be selected. The name of this option is blurred. The R&D
department is already recommended to change the name to Group Cell Select.
As shown in the preceding figure, different cells belong to different cell groups. Select a
cell from a different cell group to serve as a reference cell. You can set a cell group
through the NE Group option or by importing the cell group into an Excel file.
l Set the cell group type through the NE Group option on the Nastar.
The method of setting the cell group through the NE Group option is the same as that of configuring a
swapped cell group. A cell group is set on the WCDMA (the Nastar consists of two parts: WCDMA and
Transdata). You should use Transdata to import the MML script of the cell group to be configured to the
Nastar project in advance. Otherwise, the cell group cannot be configured.
The Excel data format must strictly follow the data format shown in the preceding table. The cells in the
configured cell group must correspond to the MML script that is imported in the Nastar project in advance.
That is, the imported cell must exist in the Nastar database. Otherwise, the cell group cannot be set. In this
sense, the two methods of configuring a cell group are consistent.
concern. Here, you should determine the parameter change by yourself or avoid
parameter change in the configuration file for parameter comparison.
List of Reference
1) HUAWEI BSC6800 WCDMA RNC Operation Manual Data Configuration
2) Subject S RNO Equipment Room Operation Guide
3) WCDMA NodeB V100R003 BTS3812-3806-3806A Electric Antenna Operation
Guide-209050919-A-1.1
4) WCDMA NodeB V100R005 BTS3812E-DBS3800 Electric Antenna Installation
and Operation Guide-20050919-A-1.0
5) WCDMA RNO Load and Test Operations Guide
6) WCDMA RNO Call Tracing Data Collection Guide
7) Huawei BSC6800 RNCV100R007C01B061 Release Notes
8) Guide to NodeB Traffic Measurement by the UMTS&GSM Radio Performance
R&D Department