Professional Documents
Culture Documents
TECHCable Stayed Bridges PDF
TECHCable Stayed Bridges PDF
September 1999
and
Earthquake Engineering
Cable-Stayed Bridges -
Earthquake Response and Passive Control
Guido Morgenthal
Dissertation submitted by
Guido Morgenthal
in
September 1999
I would like to express my deep gratitude to my two supervisors for this dissertation. Firstly my
thanks must go to Professor A. S. Elnashai for his help and guidance throughout the year. His
lectures have laid a sound foundation for the work on this project and his constant support even
during my stay in Italy is greatly appreciated.
Equally important, I would like to thank Professor G. M. Calvi from the Structural Mechanics
Section of Universit di Pavia. Through him I had the opportunity to work on a fascinating
project and to experience a beautiful country and a lovely town at the same time. His generosity
in taking time to discuss the progress of my work and his support in organising my stay were
essential for my completing the work in time.
The comments of Professor N. Priestley and the help of the other people at San Diego are also
gratefully acknowledged.
Finally and most importantly, I would like to thank my parents who are always there for me.
I am grateful for their encouragement and unending support.
Introduction Page 4
TABLE OF CONTENTS
Acknowledgements 3
Table of contents 4
1 INTRODUCTION 6
1.1 Preamble 6
1.2 Significance of long-span bridges 7
1.2.1 Impact of bridges on economy 7
1.2.2 The trans-European transport network 7
1.3 Recent cable-stayed bridge projects 8
1.3.1 resund Bridge, Sweden 8
1.3.2 Tatara Bridge, Japan 9
1.3.3 The Higashi-Kobe Bridge, Japan 10
7 SUMMARY 76
8 REFERENCES 78
APPENDIX
Introduction Page 6
1 INTRODUCTION
1.1 Preamble
Man's achievements in Structural Engineering are most evident in the world's largest bridge
spans. Today the suspension bridge reaches a free span of almost 2000m (Akashi-Kaikyo
Bridge, Japan) while its cable-stayed counterpart can cross almost 1000m (Tatara Bridge, Japan,
Normandie Bridge, France, Figure 1). Cable-supported bridges therefore play an important role
in the overcoming of barriers that had split people, nations and even continents before.
It is evident that they are an important economical factor as well. By cheapening the supply of
goods they contribute significantly to economical prosperity.
Cable-stayed bridges, in particular, have become increasingly popular in the past decade in the
United States, Japan and Europe as well as in third-world countries. This can be attributed to
several advantages over suspension bridges, predominantly being associated with the relaxed
foundation requirements. This leads to economical benefits which can favour cable-stayed
bridges in free spans of up to 1000m.
Many of the big cable-stayed bridge projects have been executed in a seismically active environ-
ment like Japan or California. However, very few of them have so far experienced a strong
earthquake shaking and measurements of seismic response are scarce. This enforces the need for
accurate modelling techniques. Three methods are available to the engineer to study the
dynamic behaviour: forced vibration tests of real bridges, model testing and computer analysis.
The latter approach is becoming increasingly important since it offers the widest range of possi-
ble parametric studies. However, testing methods are still indispensable for calibration purposes.
Herein the seismic behaviour of the Rion-Antirion cable-stayed Bridge, Greece, is studied by
means of computer analyses employing the finite element method. A framework of performance
criteria is set up and within this different possible structural configurations are investigated.
Conclusions are drawn regarding the effectiveness of deck isolation devices.
Introduction Page 7
It is evident that in this situation bridging the gap is worth considering. Cable-supported bridges
offer the possibility to cross even very large distances without intermediate supports. Hence, it is
only since their development, that people can consider crossings like the Bosporus (Istanbul -
Anatolia, completed 1973 and 1988), resund (Denmark - Sweden, to be completed 2000), the
Strait of Messina (mainland Italy - Sicily, design stage finished), the Strait of Gibraltar (Spain -
Morocco) or the Bering Strait (Alaska - Russia).
Of course infrastructure projects like these are costly. Countries take up high loans to afford
these road links. Cost-benefit analyses are inevitable as proof for banks. However, the number
of already executed major projects emphasises that even the exorbitant costs can be worthwhile.
The bridges become an important factor for the whole region and can significantly boost the
industry on both sides of the new link.
Furthermore and equally importantly, those bridge projects can become a substantial factor in
the cultural exchange among people.
The objectives of the network were defined by the European Parliament as follows:
It is apparent that the connections as means of interoperation between sub-networks are one of
the most important components within the network. Many of the currently planned major
bridges in Europe are therefore part of the network and supported by the EU. Among them are
the resund and Rion-Antirion Bridges which are discussed subsequently.
For a combined road and railway cable-stayed bridge the center span of 490m (8th largest cable-
stayed bridge in the world) is remarkable. A steel truss girder of dimensions 13.5x10.5m was
Introduction Page 9
employed to accommodate road and railway traffic on two levels. The concrete slab is 23.5m
wide and provides space for a 4 lane motorway.
The structurally more difficult harp pattern (see section 2.1.2.1) was chosen for aesthetic
reasons. It should be mentioned that the struts of the girder were inclined according to the angle
of the cables which is favourable from the structural as well as pleasing from the aesthetic point
of view.
The money for the project was borrowed on the international market and jointly guaranteed by
the governments of Denmark and Sweden. It will be paid back from the toll fees introduced.
Being part of the trans-European transport network the link will be one of the most important
European Structures carrying railway and at least 11,000 vehicles per day.
The girder is a steel box section with a streamlined shape to decrease wind forces. It is 31m
wide and only 2.70m deep. To act as counterweight the deck in parts of the sidespans is made of
concrete. At the towers the girder is kept free because of high temperature induced forces in the
case of a fixing.
In model tests it was found to be necessary to install additional damping devices for the cables.
Particularly the upper ones (the longest one having a length of over 460 m - the longest stay
cable ever) were found to be prone to wind and rain induced vibration. Additional ropes
Introduction Page 10
perpendicular to the stay cables were installed and connected to damping devices at the deck.
This yielded cable damping ratios of over 2% of critical.
The Tatara Bridge is being constructed in an area of high seismicity. It was designed for an
earthquake event of magnitude 8.5 at a distance of 200km. The fundamental period of the bridge
is 7.2s being associated with a longitudinal sway mode.
All information about the Tatara Bridge were taken from [33].
The bridge's main span is 485m with the side span being 200m each. The main girder is a
Warren truss with height a of 9m. It accommodates 2 roads at the top and bottom of the truss
respectively. Both of these have three lanes, the width of the truss being 16m.
For the cable system the harp pattern was chosen. The steel towers are of the H-shape and have
a height of 146.5m. These are placed on piers which are founded on caissons of size 35 (W) x
32 (L) x 26.5 (H) m.
An important feature of the bridge is that the main girder can move longitudinally on all its
supports. This results in a very long fundamental period which was found to be favourable for
the seismic behaviour.
On 17 January 1995 Kobe was struck by an earthquake of magnitude 7.2. Although the Higashi-
Kobe Bridge performed well in this earthquake, certain damage did occur which was reported in
[44]. Important information about the soil behaviour could be obtained from this event because
the bridge was instrumented. These will be further discussed in section 2.3.3.
State of Research on Cable-Stayed Bridges Page 11
In this section a brief overview of the structural configuration and the load resisting mechanisms
of cable-stayed bridges is given. This is necessary because they are in many ways distinctly
different from beam-type bridges and these differences strongly affect their behaviour under
static as well as dynamic loads. It has to be noted that herein only the current trend of design can
be described. An outline of the evolution of cable-stayed bridges and more elaborate
information can be found elsewhere: [50], [87].
- stiffening girder,
- cable system,
- towers and
- foundations.
The stiffening girder is supported by straight inclined cables which are anchored at the towers.
These pylons are placed on the main piers so that the cable forces can be transferred down to the
foundation system. As an example the configuration of the Tatara Bridge is given in Figure 5.
It is apparent from the picture that the close supporting points enable the deck to be very slim.
Even though it has to support considerable vertical loads, it is loaded mainly in compression
with the largest prestress being at the intersection with the towers. This is due to the horizontal
force which is applied by each of the cables. This characteristic also distinguishes the cable-
stayed bridge from the suspension bridge because necessary provisions for anchoring cables are
much more relaxed. Often cable-stayed bridges are even constructed as being self-anchored.
The particular components of this bridge type will now be discussed in more detail. However, if
more comprehensive information are sought the reader is referred to [50] and [87].
State of Research on Cable-Stayed Bridges Page 12
The cable system connects the stiffening girder with the towers. There are essentially 3 patterns
which are used:
- fan system,
- harp system and
- modified fan system.
These are depicted in Figure 6. All of these patterns can be used for single as well as for double
plane cable configurations.
In the fan system all cables are leading to the top of the tower. Structurally this arrangement is
usually considered the best, since the maximum inclination of each cable can be reached. This
enables the most effective support of the vertical deck force and thus leads to the smallest
possible cable diameter.
The fan system causes severe detailing problems for the configuration of the anchorage system
at the tower. The modified fan system overcomes this problem by spreading the anchorage
points over a certain length. If this length is small, the behaviour is not significantly altered.
The stay cables are an important part of the bracing system of the structure. It was found that
their stiffness is highest when the cable planes are inclined from the vertical. This favours A-
shaped towers with all the cables being attached to one point or line at the top.
In the harp system the cables are connected to the tower at different heights and placed parallel
to each other. This pattern is deemed to be more aesthetically pleasing because no crossing of
cables occurs even when viewing from a diagonal direction (in contrast see Figure 1). However,
this system causes bending moments in the tower and the whole configuration tends to be less
stable. However, excellent stiffness for the main span can be obtained by anchoring each cable
to a pier at the side span as was done for the Knie Bridge, Germany ([87]).
Most of the recent cable-stayed bridges, particularly the very long ones, are of the modified fan
State of Research on Cable-Stayed Bridges Page 13
type with A-shaped pylons for the discussed reasons. However, there are still many variations
regarding the configuration of the abutments, piers and towers and their respective connection
with the stiffening girder. These problems will be discussed subsequently in the light of the
dynamic behaviour.
The success of cable-stayed bridges in recent years can mainly be attributed to the development
of high strength steel wires. These are used to form ropes or strands, the latter usually being
applied in cable-stayed bridges.
- helically-wound strand,
- parallel wire strand and
- locked coil strand.
Figure 7: Helically-wound, parallel wire and locked coil cable strands ([50])
The first two types are composed of round wires. Helically-wound strands comprise a centre
wire with the other wires being formed around it in a helical manner. They have a lower
modulus of elasticity than their parallel counterparts and furthermore experience a considerable
amount of self-compacting when stressed for the first time.
Locked coil strands consist of three layers of twisted wire. The core is a normal spiral strand. It
is surrounded by several layers of wedge or keystone shaped wires and finally several layers of
Z- or S-shaped wires. The advantages of this type of cable are a more effective protection
against corrosion and more favourable properties compared with the previous arrangements.
First, the density is 30% higher, thus enabling slimmer cables which are less sensitive to wind
impact. Second, their modulus of elasticity is even 50% higher compared with a normal strand
of same diameter. Third, they are largely insensitive to bearing pressure because of a better
interaction of the individual wires.
The vast majority of modern cable-stayed bridges use galvanised locked-coil wire strands. These
are assembled to the large diameter cables, which are usually parallel strand cables.
State of Research on Cable-Stayed Bridges Page 14
Cables need to be anchored at the deck as well as at the towers. For each of these connections
numerous devices exist depending on the configuration of deck and tower as well as of the
cable. Exemplary, some arrangements for tower and deck are shown in Figure 8 and Figure 9
respectively.
Cable supports at the tower may be either fixed or movable. They are situated at the top or at
intermediate locations mainly depending on the number of cables used. While fixed supports are
either by means of pins or sockets, movable supports have either roller or rocker devices.
Connections to the deck are by means of special sockets. Their configuration strongly depends
on the type of cable used. Usually these sockets are threaded and a bolt is used to allow
adjustments on the tension of the cable.
The girder can be either of concrete or steel. For smaller span lengths concrete girders are
usually employed because of the good compressional characteristics. However, as the span
State of Research on Cable-Stayed Bridges Page 15
increases the dead load also increases, thus favouring steel girders. The longest concrete bridge
that has been constructed is the Skarnsund Bridge, Norway, with a main span of 530 m ([58]).
Also composite girders have been extensively used, entering the span range above 600 m.
The shape of the stiffening girder depends on the nature of loads it has to resist. In the design of
very long-span bridges aerodynamic considerations can govern the decision. These are beyond
the scope of this work but brief account of this issue will be given. It was shown in [41], that
bluff cross sections which have a higher drag coefficient, experience considerably higher
transverse wind forces than less angular sections. Specially designed streamlined sections can
also avoid the creation of wind-turbulence at the downstream side, a phenomenon referred to as
vortex-shedding. Considerable affords are therefore made to account for these circumstances.
For the Tatara Bridge these were reported in [33].
There are three types of girder cross sections used for cable-stayed bridges:
a)
b)
c)
Figure 10: Girder cross-sections: a) simple beam arrangement (Knie Bridge,
Germany), b) box section (Oberkasseler Bridge, Germany),
c) truss (resund Bridge, Sweden) ([50])
State of Research on Cable-Stayed Bridges Page 16
Beam arrangements consist of a steel or concrete deck which is supported by either a steel or a
concrete beam. The beams carry the loads to the cables where they are anchored. Although easy
to construct and generally efficient, beam-type girders have only a small torsional stiffness
which can be undesirable depending on the structural system.
Box sections possess high torsional stiffness and can be formed in a streamlined shape thus
showing best behaviour under high wind impact. However, there are numerous possible shapes
and the choice depends on the distances between the supports, the desired width of the section,
the type of loading and the cable pattern.
Trusses have been used extensively in the past. They possess similar torsional stiffnesses as box
sections. The aerodynamic behaviour is generally good. Trusses are of steel and thus the
stiffness is high with respect to the weight. However, the high depth of the section can be
criticised for aesthetic reasons. Trusses are unrivalled if double deck functionality is desired. In
this case the railway deck can be accommodated at the bottom chord.
2.1.4 Towers
The function of the towers is to support the cable system and to transfer its forces to the
foundation. They are subjected to high axial forces. Bending moments can be present as well,
depending on the support conditions. It has already been pointed out that the towers in harp-type
bridges are subjected to severe bending moments. Box sections with high wall widths generally
provide best solutions. They can be kept slender and still possess high stiffnesses.
Towers can be made of steel or concrete. Concrete towers are generally cheaper than equivalent
steel towers and have a higher stiffness. However, their weight is considerably higher and thus
the choice also depends on the soil conditions present. Furthermore, steel towers have
advantages in terms of construction speed.
The shape of the towers is strongly dependent on the cable system and the applied loads but
aesthetic considerations are important as well. Possible configurations are depicted in Figure 11.
While I- and H-shapes are vertical tower configurations and therefore support vertical cable
planes, A- and -shaped towers correspond to inclined cable planes. The influence of these
patterns on the overall stiffness of the structure have been discussed earlier. As far as the
stiffness of the tower itself is concerned, A- and -shapes are preferable. However, their
structural configuration is significantly different from the I- and H-shape which can have
adverse effects on the ductility (cf. section 5.1.2).
2.1.5 Foundations
Foundations are the link between the structure and the ground. Their configuration is mainly
influenced by the soil conditions and the load acting.
For cable-stayed bridges often pile foundations are used, with the pier being connected to the
pile cap. Various arrangements are possible and the choice mainly depends on the magnitude of
the overturning moment.
Cable-stayed bridges often need to be founded in water. In this case caisson foundations are
used. The caisson acts as a block and can be placed either on the sea bed or, again, on piles.
Cable-stayed bridges have an inherently nonlinear behaviour. This has been revealed by very
early studies and shall be discussed in detail here because the nonlinearity is of greatest
importance for any kind of analysis.
Nonlinearities can be broadly divided in geometrical and material nonlinearities. While the latter
depend on the specific structure (materials used, loads acting, design assumptions), geometric
nonlinearities are present in any cable-stayed bridge.
- the cable sag which governs the axial elongation and the axial tension,
- the action of compressive loads in the deck and in the towers,
- the effect of relatively large deflections of the whole structure due to its flexibility
([1], [4], [9], [50], [52], [73], [74], [75], [87], [88]).
It is well known from elementary mechanics that a cable, supported at both ends and subjected
to its self weight and an externally applied axial tension force, will sag into the shape of a
catenary. Increasing the axial force not only results in an increase in the axial strain of the cable
but also in a reduction of the sag which evidently leads to a nonlinear stress-displacement
relationship. The influence of the cable sag on its axial stiffness has first been analytically
expressed by Ernst ([34]). If an inclined cable under its self weight is considered, an equivalent
elastic modulus can be calculated as follows:
State of Research on Cable-Stayed Bridges Page 18
E
Ee = (1)
1+
(w l )2 E
12 3
It is interesting to note that the above described cable behaviour leads to an increase in the
bridge stiffness if the forces are increased. This is depicted in Figure 12 and clearly distin-
guishes cable-supported structures from standard structures. They can be classified as being of
the geometric-hardening type ([2], [4], [5]).
Non-cable Structures
Cable Structures
Generalized
Displacement
Today most finite element programs offer nonlinear solution algorithms. With these it is
possible to take the above mentioned characteristics of cable-stayed bridges into account. The
nonlinear cable behaviour can be either treated utilising Ernst's formula or applying multi-
element cable-formulations. This issue will be further discussed in section 2.3.1.
The nonlinear behaviour of the tower and girder elements due to axial force-bending moment
interaction is usually accounted for by calculating an updated bending and axial stiffness of the
elements. Detailed descriptions of nonlinear element formulations can be found in [32], [57],
[107] and elsewhere.
The overall change in the bridge geometry as third source of nonlinearity can be accounted for
by updating the bridge geometry by adding the incremental nodal displacements to the previous
nodal coordinates before recomputing the stiffness of the bridge in the deformed shape ([74]).
State of Research on Cable-Stayed Bridges Page 19
The dynamic behaviour of a structure can be well characterised by a modal analysis. The linear
response of the structure to any dynamic excitation can be expressed as superposition of its
mode shapes. The contribution of each mode depends on the frequency content of the excitation
and on the natural frequencies of the modes of the structure.
The results of modal analyses of cable-stayed bridges can be found in most of the research
papers dealing with their seismic behaviour. In Figure 13 the first modes obtained by Abdel-
Ghaffar for a model bridge in [1] are shown. The first modes of vibration have very long periods
of several seconds and are mainly deck modes. These are followed by cable modes which are
coupled with deck modes. Tower modes usually are even higher modes and their coupling with
the deck depends on the support conditions between these. The influence of different support
conditions on the mode distribution has been investigated by Ali and Abdel-Ghaffar in [9]. It is
apparent from the resulting diagram shown in Figure 14 that movable supports lead to a more
flexible structure, thus shifting the graph towards longer periods. As an example, in [44] it was
mentioned by Ganev et al that the Higashi-Kobe Bridge has been deliberately designed with
longitudinally movable deck in order to shift the fundamental period to a value of low spectral
amplification. The decision upon the support conditions of the deck is usually governed by
serviceability as well as earthquake considerations. A restrained deck will avoid excessive
movements due to traffic and wind loading and may thus be preferred. However, in the case of
an earthquake a restrained deck will generate high forces which are applied to the pier-pylon
system. It is thus a trade-off and often intermediate solutions are sought. Elaborate investiga-
tions on possible damping solutions are discussed subsequently in this report.
Usually the modes obtained are classified in their directional properties. Thus, vertical,
longitudinal, transverse and torsional modes are distinguished and the order of these well
characterises the bridge behaviour without the need to depict the individual mode shapes. As an
example the first 25 modes of the Quincy Bayview Bridge, US, are given in Table 1. They have
been identified experimentally as will be discussed later.
State of Research on Cable-Stayed Bridges Page 20
Figure 13: First six computed mode shapes (considering one-element cable
discretisation) ([1])
Typical for cable-stayed bridges is a strong coupling (such as bending-torsion coupling) in the
three orthogonal directions as can also be seen in Table 1. This coupled motion distinguishes
cable-stayed bridges from suspension bridges for which pure vertical, lateral and torsional
State of Research on Cable-Stayed Bridges Page 21
motions can be easily distinguished. This also implies that three-dimensional modelling is
inevitable for dynamic analyses.
The importance of the cable vibration for the overall response of the bridge was pointed out by
Ali and Abdel-Ghaffar in [2], Abdel-Ghaffar and Khalifa in [9] and Ito in [56]. They concluded
that appropriate modelling of the cable vibrations is necessary. For this purpose multi-element
formulations for the cables are suggested. Only if the mass distribution along the cable is
modelled and associated with extra degrees of freedom the vibrational response of the cables
can be obtained. In [2] a modal analysis was performed modelling the cables with multi-element
cable discretization. It was pointed out that there is coupling between the cable and deck motion
even for the pure cable modes which suggests not to solely rely on analytical expressions for
natural frequencies of a cable alone. In [9] it was found that the natural frequencies of the cables
are strongly dependent on the cable sag as can be seen in Figure 15.
Figure 15: Effect of the sag-to-span ratio on the natural frequencies of a cable,
analytical and experimental results ([9])
An analytical method for calculating natural frequencies of cable-stayed bridges has been
developed by Bruno and Colotti in [18] and Bruno and Leonardi in [19]. Prevailing truss
behaviour and small stay spacing have been assumed and on this basis diagrams showing the
main natural frequencies depending on geometric parameters were developed. These were
compared with results from numerical analyses and a good agreement was found.
For existing bridges the modes can be obtained from vibration measurements. Ambient
vibration measurements of the Quincy Bayview Bridge, US were undertaken by Wilson et al.
The dynamic response of the bridge to wind and traffic excitation was measured. The results
obtained were reported in [94] and the mode shapes are depicted in Table 1.
State of Research on Cable-Stayed Bridges Page 22
It should be mentioned here, that a response spectrum analysis on the basis of a performed
modal analysis is highly questionable although differently stated in some older papers (e.g.
[92]). Firstly, modal superposition is only possible for linear structural behaviour, which is
usually not the case for cable-supported bridges as explained in section 2.2. Secondly, even if
linearity could be presupposed, the superposition procedure must be based on reasonable
assumptions and methods like the SRSS procedure are only valid for well-spaced modes which
is, again, not necessarily the case for cable-supported structures. Hence, the level of safety
reached would not be assessable.
There are essentially two ways in which damping is considered in most past investigations.
Firstly, energy dissipation by elastic-plastic hysteresis loss can be considered. This requires
conducting a nonlinear analysis with the application of material nonlinearity and is most
important when special energy absorption devices are to be modelled. Secondly and most
commonly, an equivalent viscous damping can be introduced in the system in the form of a
damping matrix C. Damping in cable-stayed bridges is undoubtedly not viscous. However, it is
an easy to implement and reasonable treatment of the problem as explained by Abdel-Ghaffar in
[9]. Usually the damping matrix is established using a linear combination of mass and stiffness
matrix. This is called Rayleigh damping and enables satisfying damping ratio exactly for 2
modes as shown by Clough and Penzien ([27]). An established estimate of viscous damping
ratio seems to be 2% for cable-stayed bridges. According to Abdel-Ghaffar ([1]) values of this
level have been found in many measurements. Damping ratios of 2-3% have in the past been
State of Research on Cable-Stayed Bridges Page 23
employed by many investigators in their analyses without further discussion ([1], [2], [4], [5],
[9], [10], [31], [38] , [66], [73]).
Dynamic testing of two bridge models of 3.22m length was conducted by Garevski and Severn
([47], [48]). Shaking table tests were performed as well as excitation by means of electro-
dynamic shakers. The results obtained are shown in Table 2. It is important to note that the
damping ratio notably depends on the mode under consideration. This is due to the different
mode shapes and the different member contributions in these. On the other hand it is obvious
from the differences between the testing methods that experimental results should also be used
with caution.
Model A Model B
Shaking table Portable shakers Shaking table Portable shakers
Mode Type Frequency Damping Frequency Damping Frequency Damping Frequency Damping
no. (Hz) (%) (Hz) (%) (Hz) (%) (Hz) (%)
1 Lateral 4.28 0.45 4.24 0.42 4.16 0.43 4.17 0.34
2 Vertical 6.19 0.38 6.19 0.37 5.86 0.33 5.81 0.56
3 Vertical 8.93 0.42 9.03 0.38 8.83 0.72 8.66 0.83
4 Lateral 11.88 0.29 11.88 0.26 11.39 2.01 11.58 1.00
5 Vertical 13.65 0.44 13.65 0.42 13.75 0.56 13.81 1.23
In the tests the damping ratio was found to be dependent on the amplitude of excitation and the
mode shape (cf. Figure 17) as well as on the cable pattern. Damping ratios for the fan-type
bridge were in the range between 0.6-0.8% while the harp-type structure had damping ratios
between 1.2 and 1.5%, the higher values being for higher amplitudes of oscillation. Higher
damping ratios of the harp configuration can be attributed to larger flexural deformations of the
deck in vertical direction which leads to a higher energy dissipation.
State of Research on Cable-Stayed Bridges Page 24
Because damping ratios vary with structural types, Kawashima suggested an approach in which
the energy dissipation capacity is evaluated for each structural segment ([60], [64]). From this
the overall damping can be calculated. The structural segments in which energy dissipation is
considered uniform are referred to as substructures. These could be deck, towers, cables and
bearing supports. Material nonlinearity is considered to be the prevailing mechanism for energy
dissipation. Kawashima et al reduced the problem to applying so called energy dissipation
functions for the substructures which can either be obtained by experiments or taken from their
work.
Kawashima and his co-workers also investigated the damping activated under earthquake
conditions. In [62] it is stated that in an earthquake considerably higher damping values are
found than the ones usually obtained from forced vibration tests. Hence, strong motion data
recorded at the Suigo Bridge, Japan, during 3 earthquakes were used to estimate damping
ratios. These are found to be 2% and 0-1% of critical in longitudinal and transverse direction,
respectively, for the tower, and 5% in both directions for the deck.
From their model tests of the Quincy Bayview Bridge (already mentioned in 2.3.1) Wilson et al
([94]) also obtained an estimate for the range of damping of the bridge. They found the upper
and lower bound of the damping ration for the first coupled transverse/torsion mode to be 2.0-
2.6% and 0.9-1.8% respectively.
Well established for modelling the soil-structure interaction is the substructure approach,
described by Betti et al in [16]. It deals with each part of the system (soil, foundation,
superstructure) separately. The main advantage is that the analysis of each subsystem can be
performed by the analytical or numerical technique best suited to that particular part of the
problem: e.g. finite element method for the superstructure, continuum mechanics analysis for
the soil. The individual responses are combined so as to satisfy the continuity and equilibrium
conditions.
The other modelling approach comprises the so called direct methods. Here, the soil is included
in the global analysis model. Different element formulations and properties can be used for soil
and structure but the problem is solved as one. This imposes great importance on the boundary
conditions to be used in the model. For further treatment of this problem reference is made to
the publications by Wolf: [95], [96].
Zheng and Takeda in [106] investigated the applicability of soil-spring models for foundation
systems. Analyses on a 2-D finite element model of the soil were compared with those of the
simplified model. It was found that the simplified model shows good agreement with reality for
low frequency input motions while the errors increase for higher frequencies. In Figure 18
transfer functions for both horizontal and vertical motions are shown. These results suggest that
a mass-spring model would be a good approach for the analysis of long-period structures like
cable-stayed bridges. However, the contribution of higher modes could be underestimated.
Figure 18: Transfer functions for horizontal and vertical component of effective
input acceleration at top of foundation computed by 2-D FEM and
mass-spring model ([106])
Elassaly et al in [31] presented results of a case study investigating the effects of different
idealisation methods for a pile foundation system on the earthquake forces acting on the
structure. Two cable-stayed bridges were studied in this context. Firstly, a so called Winkler
foundation making use of spring and damper elements was employed. Secondly, a discretization
of the surrounding soil with plain strain elements was used as shown in Figure 19.
State of Research on Cable-Stayed Bridges Page 26
Figure 19: Modelling approaches for soil-pile interaction; top: Winkler model,
bottom: plain strain finite element modelling ([31])
It should be emphasised that, in contrary to other investigations, the bridge superstructure was
modelled entirely, too. This is deemed to be important, since it significantly contributes to the
interaction between soil and foundation. It could be shown in time-history analyses, that
neglecting the effects of local soil conditions and the soil-structure interaction results in a great
underestimation of displacements of the superstructure particularly for soft soils. Under-
estimation mainly occurs if the soil site has a fundamental frequency close to the one of the
structure. In terms of simplified approaches it was stated that fixed base modelling approaches
can only be justified for structures founded on rock. On the other hand, the accuracy of
employing an "equivalent stiffness" strongly depends on the conditions of the case in question
and the way in which this stiffness has been evaluated.
Investigations on the response of the Higashi-Kobe Bridge (see also section 1.3.3) and the
surrounding soil during the Hyogoken-Nanbu Earthquake have been undertaken by Ganev et al
([44]). Time-histories that were recorded by the downhole soil accelerometer and the surface
accelerometer showed clear evidence of liquefaction. Because the acceleration at the surface is
smaller than the one at 34m depth and exhibits longer period motions, it was concluded that the
surface soil layers which consist of loose saturated sands had actually been liquefied during the
earthquake. The measurements from the instrumented bridge could also be employed to validate
numerical approaches for analysis of soil-structure interaction. Extensive analyses using
different computer codes have been conducted in this context. In the present case one of the
most important issues associated with interaction analysis is the degradation of the soil stiffness.
Three factors are considered to have the largest effect on this: non-linear stress-strain
State of Research on Cable-Stayed Bridges Page 27
dependence of the soil material, separation of soil from the structure and pore-water pressure
buildup. For explanations on the modelling approach used to take these into account the reader
is referred to the paper mentioned above. Good correlation between the instrumentation data and
the numerical analyses could be achieved as can for example be seen in Figure 20.
Control of dynamic response can be either active or passive. While active control is dependent
on external power supply, passive devices are not. Active control is essentially based on
avoiding the impact of forces by modifying the vibration in a favourable way, e.g. additional
masses are controlled so as to counteract the inertial forces of the structural members. For cable-
stayed bridges special solutions like "active tendon control" (Achkire et al [6], Warnitchai et al
[90]) have been developed. In this, sensors near the lower anchorage of the cables detect the
girder motion. Passed through a linear feedback operator the resulting signals are fed to
servohydraulic actuators fixed at the cable ends. These actuators change the cable tension,
therefore providing a time-varying force upon the girder. This mechanism is depicted in
Figure 21.
Results of investigations on the effectiveness of active tendon control can be found in [84], a
recent paper by Schemmann et al.
State of Research on Cable-Stayed Bridges Page 28
Although active control can be highly effective, the costs are obstructive and for an emergency
situation like an earthquake the dependence on electrical power is deemed to be unfavourable.
Passive control is based on energy dissipation in special devices. These devices are placed at
critical zones such as the deck-abutment and deck-tower connections to concentrate hysteretic
behaviour in these specially designed energy absorbers. Inelastic behaviour in primary structural
elements of the bridge can therefore be avoided, assuring the serviceability after an earthquake.
The Rion-Antirion Bridge will cross the Gulf of Corinth near Patras in western Greece. It is part
of the country's new west axis, a major national transport project. This highway will connect
Kalamata in the south, Patras, Rion, Antirion and Igoumenitsa in the north. Being linked with
two other major axes it forms part of a new high-performance transport network which is also a
part of the trans-European network described in section 1.2.2. The objective is to establish direct
access of all major urban centers of Greece (Patras, Athens, Lamia, Larissa, Thessaloniki) from
the developing neighbouring countries in the Balkan region, the other European countries and
the east. Vital is also the connection of the major harbours to the network.
The main part of the Rion-Antirion Bridge is a continuous multi-cable-stayed bridge, supported
by four large pylon/pier structures named M1, M2, M3 and M4 resting on the sea bed. Double
cantilevers are built from each of the pylons. Final junctions are then made between the central
cantilevers and the outer parts are extended towards the transition piers so that the final span
lengths are 286, 3x560 and 286 m. The transition piers are connected to approach viaducts.
The bridge has two 9.50m wide carriageways, separated by a 0.50m wide central separator with
a double safety fence and bounded by lateral crash barriers.
- two main longitudinal steel girders, 2.20m high, spaced at 22.10m. These beams are
I-shaped plate girders with variable sections, the maximum width of the lower
flange being 2.00m.
- Transverse I-shaped plate girders spaced at 4.06m. Both longitudinal and transverse
beams include stiffeners to avoid local buckling of the steel plates.
- A top reinforced concrete slab connected with the girders by steel studs. The
concrete grade is C60/75. The slab thickness is generally 25cm, increased to up to
40cm above the girders.
The overall slab width is 27.20m including two 1.95m wide cantilevers. The central part
between the main steel girders is precast to ensure best concrete quality.
The deck is supported by steel stay cables. These are anchored directly above the web of the
main girders.
It should be noted that the deck is only supported by the stay cables at the main pylons. No
bearings are provided to the deck by the piers. However, isolation and dissipation devices are
planned to be placed between the deck and the pylon base in transverse direction. These are to
limit the relative displacements between the deck and the piers in the case of a severe
earthquake.
The Rion Antirion Bridge Page 31
The pylon legs are square shaped concrete box girders, the outer section of these being 4.0x4.0m
and the minimum wall thickness being 60cm. The pylon head is 35.0m high and has a square
hollow section of 8.0x8.0m.
The pylon base is composed of four prestressed concrete beams, 3.50m high and 6.00m wide.
These beams form a square grid of 40.0x40.0m. They provide a structural junction between the
pier head and the pylon legs and also constitute the anchorage for the isolating devices between
deck and pier.
The main piers are reinforced concrete structures, consisting of the following parts:
- the "pier head": a spatial structure of height 15.28m and varying thickness, joining
the square pylon base to the octagonal pier shaft,
- the "pier shaft" with its base 3m above mean sea level. Because of the variable
height of the deck the length of this pier shaft is different for the four piers.
- The "cone" allows the adaptation to the actual soil level at each pier site. Hence, the
length of the cones varies for the certain piers. They have an external diameter of
26.0m at the top and of 38.0m at the base.
- The roughly cylindrical "footing" consists of a system of walls and slabs for stability
reasons and has a diameter of 90m. The external wall is cylindrical and has a
thickness of 0.80m.
The footing and the very first meters of the cone are constructed in a dry dock and towed out to
a wet dock where the cone walls are completed. The pier shaft slab and the upper pier are
completed on site after the base has been immersed to its final position. The various compart-
ments of the stiffener ring as well as the hollow central part are filled by a concrete or a gravel
pier ballast adjusted to ensure the stability of the pier at any time.
The transition piers act as junction between the high bridge and the approach bridge. Their
design has not been finalised yet. However, the following conditions will apply:
- in the transverse direction, the conditions of the main piers are likely to be adopted.
Isolation and energy dissipation devices are provided for improving the earthquake
behaviour.
The two planes of stay cables are arranged in the semi-fan pattern. Each of the spans is
supported by 4 sets of 23 cables. The horizontal spacing of cables along the deck is 12.174m.
The cables have increasing numbers of parallel strands towards the mid-span. Each strand has an
area of 150mm2 .
At the pylon head the cables are anchored with typical threaded anchorages that permit
adjustment if required.
The Rion Antirion Bridge Page 33
The bridge also has to accommodate possible fault movements which lead to horizontal
displacements of one part of the bridge with respect to the other. The tectonic movement and the
thus caused expansion has been discussed in a paper by Ambraseys and Jackson ([13]). Using
records of earthquakes in Central Greece since 1694 they found an average extension rate of the
Gulf of Corinth of 11mm/year.
Finite Element Model of the Bridge Page 34
4.1 Introduction
For purposes of static and dynamic analysis a finite element model of the Rion-Antirion Bridge
was set up for use in the program system ADINA ([7]). It is depicted in Figure 25. As summary,
Table 3 lists the mass distribution within the model.
M1 M2 M3 M4
[kt] [kt] [kt] [kt]
Deck 18.4 18.8 18.5 18.4
Cable Stays 1.4 1.4 1.4 1.4
Pylons 11.5 11.5 11.5 11.5
Piers 149.1 157.5 159.4 121.9
Structural mass 180.4 189.2 190.8 153.2
Table 3: Mass distribution of the bridge
The bridge was modelled in full taking into account all major structural components and their
characteristics. Since the properties could be taken from design documents the bridge model
reflects an actual structure designed to all code requirements which was not the case for all
earlier investigations on cable-stayed bridges.
The accuracy of finite element analyses naturally depends on the assumptions made for setting
up the model. A description of the model and these assumptions will thus be given
subsequently.
The finite element model of the bridge deck is depicted in Figure 26.
Finite Element Model of the Bridge Page 35
A modelling approach suggested by Wilson and Gravelle in [93] was utilised. This comprises
introducing a single central spine of linear elastic beam elements that has the actual bending and
torsional stiffness of the deck. These stiffnesses were evaluated by establishing an equivalent
steel cross section, thus taking into account the concrete contribution. The cross section of the
deck is not uniform along the bridge which was taken into account while setting up the deck
spine elements. The torsional stiffness is the most difficult one to evaluate. The deck will have
both pure and warping torsional stiffnesses. As an approximation, the deck cross section (shown
in Figure 23) was considered to be a thin-walled open C-shaped section.
Each of the spine beam elements has a length of approximately 12m, spanning from one cable
anchor location to the next. At these nodes two rigid links were placed on either side
perpendicular to the spine to attach the cable elements, thus achieving the proper offset of the
cables with respect to the centre of inertia of the spine. Using the rigid link option allows the
displacements of the "slave" node to be expressed in terms of the displacements of the "master"
node, thus not introducing additional degrees of freedom into the model.
Since the spine beam does not allow for the torsional inertia effects of the real bridge additional
lumped masses were attached on either side of the central spine. By placing these below the
level of the spine the difference between the centre of stiffness and the centre of mass can be
accounted for. This produces coupling between the torsional and the transverse motions of the
deck.
Truss element
z
Y
Spine M
Lumped mass
(position changes depending
on section properties)
It should be mentioned that linear elastic elements have also been used by Wilson et al in [93].
Even though the authors suggested that the error is not significant it is clear that this approach
can lead to considerable inaccuracies.
d
Figure 28: Employed cable behaviour
A prestress was applied to all the cables in order to ensure small deformations of the deck when
the self weight is applied. The bridge was modelled picking up the geometry from the design
drawings. Since these show the as-built configuration the application of the self-weight to the
structure has to be taken into account. In reality the cables are prestressed according to a prior
calculation so that the final shape is correct. Accordingly, in the present study the prestress was
adjusted so as to have as small as possible a deflection when the self-weight is applied.
The piers were modelled with a single set of beam elements. The change in the cross-section
along the cone was taken into account. However, in preliminary studies the stiffness of the
cantilever was found to be inaccurate and a calibration analysis using a refined model was
conducted as described in section 4.4.
The pylon legs have been connected to the piers using rigid links. This was done because the
pier head was deemed to be extremely stiff in terms of relative rotations between the pier top
and the base of the pylon. The pylon legs unify at the pylon head which was divided into beam
elements as long as the distance between the cable anchorage points, thus readily allowing for
the connection of the cable elements.
Finite Element Model of the Bridge Page 37
An important feature for the present study was the damping system connecting the deck and the
pylon base. To accommodate these, rigid links were placed between the top of the pier and
points at the level of the deck on either side of it. This enabled the damping devices only to act
in the transverse direction because they have no component in longitudinal and vertical direction
as can also be seen in Figure 29.
The interaction between soil and structure was modelled using linear damped springs in the
vertical direction and nonlinear undamped springs in the horizontal directions. Nonlinear springs
were also applied for the bending rotational degrees of freedom.
As was already mentioned in 3.2.5, the Rion-Antirion Bridge is to be built on very weak soil
deposits. Extensive investigations on the soil properties were conducted by the designers and
equivalent spring stiffnesses, including the contribution of the piles, were available from these.
To retain the advantage of having a model close to reality it was decided to make use of these
properties. As will be explained subsequently, there was also concern that the nonlinearities in
the soil could play an important role in the behaviour of the bridge, thus making it necessary to
take them into account. As an example, the characteristics of the nonlinear springs at pier M3
are shown in Figure 30. The linear spring's properties are:
15000
10000
5000
0
0.000 0.002 0.004 0.006 0.008 0.010
Rotation [rad]
The modelling approach employed for the base of the piers is depicted in Figure 31. As
explained, nonlinear springs with the behaviour adopted from design documents were applied in
horizontal direction. These were identical in both directions at each pier, but different from pier
to pier. In vertical direction linear springs were applied. The rotational springs, not shown in
Figure 31, have nonlinear behaviour and are the same for the two bending and different for the
torsional degree of freedom.
Pier F
d
x-acclgr.
d
d
F
F
.
gr
cl
ac
y-
Rotational springs
z-acclgr.
To the end point of the translational springs the accelerograms were applied, thus exciting the
structure via the ground springs.
Finite Element Model of the Bridge Page 39
4.3 Accelerograms
Synthetic accelerograms have been used in the present study that were derived from actual
earthquake records using a special procedure to fit them to a predefined spectrum. These spectra
that are referred to as KME spectra have been agreed upon with the client, the Greek
government.
The spectrum compatible accelerograms have been derived by the designers and are for the
purpose of structural analysis. The real earthquake records that have been used as basis are listed
in Table 4.
The last column shows the A/V ratio. This is a good measurement for the demand of the record.
Records with low A/V ratios (smaller than unity), as have all of the ones used here, tend to have
higher spectral accelerations in the long period range. Hence, the records can be expected to
impose high demand on a long period structure like a cable-stayed bridge.
The records obtained were scaled so as to represent a return period of 2000 years, thus imposing
a very high demand on the structure. This means that a design earthquake was considered which
is only appropriate for a very important structure.
The accelerograms and their response spectra are shown in Figure 32 through Figure 37. It is
apparent from the response spectra that the records impose a high demand on a long period
structure.
Finite Element Model of the Bridge Page 40
Acceleration [m/s2]
4.00
2.00
0.00
-2.00 0 20 40 60 80 100
-4.00
-6.00
Time [s]
12.00
10.00
8.00
6.00
4.00
2.00
0.00
0 1 2 3 4 5 6 7 8 9 10
Period [s]
4.00
2.00
0.00
-2.00 0 20 40 60 80 100
-4.00
-6.00
Time [s]
8.00
6.00
4.00
2.00
0.00
0 1 2 3 4 5 6 7 8 9 10
Period [s]
3.00
2.00
1.00
0.00
-1.00 0 10 20 30 40 50 60
-2.00
-3.00
-4.00
Time [s]
0.80
0.60
0.40
0.20
0.00
0 1 2 3 4 5 6 7 8 9 10
Period [s]
Calibration investigations for the simplified beam model of the piers were conducted in order to
ensure stiffness conditions compatible with reality. It was this deemed necessary because of the
exceptional pipe-type cross-section of the piers with diameters of more than 30m. Such a
structure can be expected to show considerable shear effects and therefore a refined model was
set up in order to assess the influence of these.
Figure 38 shows the model which was established using shell elements. On this static analyses
were performed applying a unit force and moment to the top of the pier.
The displaced shape under a unit load at the top of the pier is shown in Figure 39. The
displacements resulting were compared with those arrived at by using pure bending theory beam
elements with the correct cross-section. As was expected, the refined model showed larger
deflections. These could be reached with the simplified model by using shear modelling and
calibration was done by calculating the correct shear area. This enabled modelling the actual
shear behaviour in a simplified fashion. The shear area found to be adequate was by a factor of
2.3 larger than the actual cross-sectional area which suggests that the structure undergoes
considerable distortion.
Finite Element Model of the Bridge Page 43
In the context of this report it was deemed particularly important to know about the transverse
displacements that the deck undergoes in the case of relative displacements between the piers.
These strongly depend on the stiffness distribution within the bridge and the boundary
conditions, meaning the way in which the deck is restrained.
Two cases were considered here: a strike-slip fault located in the middle span causing transverse
relative displacements between the piers and, for completeness, a normal fault causing
longitudinal extension of the bridge.
The deformed shape of the bridge for transverse displacements in the fault of 40 cm is shown in
Figure 40.
The analysis was done for a deck freely movable in longitudinal as well as in transverse
direction. This is realistic, since a rigid shear connection is not planned for the bridge in order
not to impose additional forces on the piers in the case of tectonic movements. It is apparent
from the figure, that the largest relative displacements between deck and pylons occur at the
towers adjacent to the mid-span. These are about one third of the absolute relative displacement
in the fault and should be considered in further investigations on bridge deck deformations as
reported upon in section 6.
Also, the response of the bridge to an extension of the strait was investigated. A relative
displacement of 2m between the two middle towers causes a deformation as shown in Figure 41.
The bridge deck is lifted upwards in this case.
Characteristics of the Rion-Antirion Bridge Page 45
The maximum vertical displacement of the deck occurs at mid-span. It has a value of almost 2.5
times the absolute displacement between the towers. This shows that in the case of tectonic
movements adjustments in the cable tensions could be necessary.
Analyses were performed for forces pushing at heights of 78 and 92m above the pier head in
transverse and diagonal direction, the results being shown in Figure 43. The displacements in
this diagram are relative displacements between the point of pushing and the pier top excluding
the displacements caused by the rotations at the pier top. Referring to Figure 42 these are
displacements d5 .
92m: transverse
100
92m: diagonal
78m: transverse
78m: diagonal
80
Force [MN]
60
40
20
0
0.0 0.2 0.4 0.6 0.8 1.0 1.2
Deflection [m]
The results of the push-over analyses shall not be discussed herein. Figure 44 gives an
explanation of the significant events which induce changes in stiffness.
Deflection (in)
0 8 16 24 32 40
120,000
ax = 76% steel strain = 0.06: tension leg (top)
24,000
100,000 ax = 68%
hinge: tension leg (bottom)
ax = 65% hinge: tension leg (top) 20,000
ax = 62% axial tension cracking along entire leg
80,000
axial tension cracking at top
Forc e (kip s)
Forc e (kN )
ax = 57% 16,000
hinge: steel strain = 0.06
hinge: tension leg tension leg (top)
compression (bottom) ax = 50%
60,000 leg (top) ax = 49%
ax = 49%
hinge: 12,000
tension leg
(top)
ax = 45%
40,000
Force-Deflection Curves
8,000
92m : Transverse
78m: Transverse
20,000
4,000
0 0
Deflection (m)
Figure 44: Explanation of events in push-over analysis
Characteristics of the Rion-Antirion Bridge Page 47
It should be mentioned here that the results of the analysis with the pushing force at 92m have
been used for the subsequent investigations. Hence, relative displacements within the pylon are
measured with respect to the 92m point.
Modal analyses have been conducted on the bridge model in order to investigate the basic
dynamic characteristics of the bridge. Different combinations of boundary conditions for the
deck have been considered as described in Table 5. The piers have been fixed at the base in all
cases.
Table 6 shows the first 20 modes for the model 2 which has a deck freely movable in
longitudinal and fixed in transverse direction. The modal mass participation is given as well as a
description of the nature of the modes. The fundamental mode with period 7.5s is a vertical
mode as depicted in Figure 45. The first modes are all deck modes of various shapes. These can
be grouped into vertical, transverse and torsional modes, the first ones of each being shown in
Figure 45, Figure 46 and Figure 47 respectively.
The distribution of the modal periods is shown in Figure 48. Only the first 8 modes have periods
above 3s. Below 3s many closely spaced modes follow.
5.00
4.00
3.00
2.00
1.00
0.00
0 100 200 300 400 500 600
Mode number
Figure 48: Distribution of modal periods, model 2 (free in x-dir., fixed in y-dir.)
Because the deck has only a small mass compared to the whole structure (cf. Table 3) the modal
masses of the deck modes are relatively small. This particularly applies to the higher deck
modes. The accumulated modal mass in longitudinal direction is shown in Figure 50. In this the
tower modes which contribute significantly can be located clearly. The first tower mode is mode
261. The tower mode with the highest modal mass participation of 8.2% in longitudinal
direction is depicted in Figure 49.
Characteristics of the Rion-Antirion Bridge Page 49
These results show clearly that the contribution of the higher modes is important and needs to be
taken into account. However, also first modes contribute considerably, causing susceptibility to
long period excitation.
80.00
70.00
60.00
50.00
40.00
30.00
20.00
10.00
0.00
0 100 200 300 400 500 600
Mode number
Figure 50: Accumulated modal mass participation, model 2 (free in x-dir., fixed
in y-dir.)
In order to compare the behaviour of the different models analysed, the period distributions of
these are shown jointly in Figure 51.
Characteristics of the Rion-Antirion Bridge Page 50
12.0
Model3
10.0
8.0
Model4
6.0
4.0
2.0
0.0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mode No.
For models 1 and 3 which have a free deck in transverse direction, the fundamental mode is a
transverse sway mode of period 18.6 s. Given that the period of a pendulum is (G. Galilei)
l
Tpendulum = 2 (2)
g
the fundamental period of the bridge can be easily verified, knowing that the vertical distance
between pylon top and deck is 95 m:
95m
Tpendulum = 2 = 19.6s . (3)
g
The actual deck is just a bit stiffer than an equivalent pendulum system.
It is apparent from Figure 51 that the first modes are mainly affected by the movability of the
deck in transverse direction. Fixing the deck in longitudinal direction shifts the period
distribution downwards, but only by a small amount.
Earthquake Response and its Control Page 51
6.1 Introduction
The aim was to firstly understand the influence of the bridge deck and its connection to the
piers. Two basic cases were studied at first:
Within the framework established investigations on possible isolation devices for the bridge
deck have been conducted. The objective was to better understand the impact that devices with
different properties have on the bridge response to find a realistic solution.
6.2.1 Introduction
In the context of later evaluating possible isolation devices for the bridge deck, investigations
were started by considering two basic cases: a deck completely free in transverse direction and a
deck rigidly connected to the pier top (shear key). This allowed for a better understanding of the
behaviour characteristics and critical parameters.
Also, the influence of the components of the earthquake motion was studied by applying the
components described in section 4.3 in different combinations.
The finite element model introduced in section 4 was used. The following conditions apply to all
analyses conducted:
Time steps of 0.02s enable capturing of modes up to a period of 0.126s which corresponds to
modes in the order of 440. Hence, the modal sum of the modal masses properly represented by
the analyses is approximately 80%. Higher values could only be attained by using considably
shorter time stepping and thus increasing the computation time. Inaccuracies may result but
these will be confined to the tower response.
model y (transverse)-direction
1 free
2 fixed
Table 7: Boundary conditions for the deck
Model 1 was analysed with combinations of ground motion components as shown in Table 8
while model 2 was only analysed with all components acting.
6.2.3 Results
From the analyses the maxima in the time domain were obtained for certain parameters. For the
case with all ground motion components acting some of these are listed in Table 9. All
displacements regarding pier behaviour were monitored at tower M3. This tower was chosen
because it has the longest piers as well as the weakest soil and is therefore supposed to deliver
upper bound solutions.
An important value is the maximum relative displacement between the deck and the pier which
is 95cm for a free deck (cf. the plot in Figure 52). However, it can easily be seen from Table 9
that fixing the deck in transverse direction does not only affect the relative displacements
between deck and pier. The absolute displacements in the mid-span are decreased by almost
80% and even the displacements of the pylon top are decreased.
0.8
0.6
0.4
0.2
0.0
-0.2
-0.4
-0.6
-0.8
-1.0
0. 10. 20. 30. 40. 50. 60. 70. 80. 90.
Figure 52: Transverse displacements [m] of the deck relative to the pier M3,
model 1 (free deck)
For the case of a rigid connection the maximum force applied on the pier by the deck has been
found to be 63.7MN (cf. the plot in Figure 53). Knowing this, it is most interesting to note that
the transverse deformation in the soil springs is by almost 70% smaller for the rigid deck model.
Although a very high transverse force is applied to the pier top, the displacements in the soil are
decreased. This points out, that by fixing the deck the whole structure is changed in its dynamic
characteristics.
6.
4.
2.
0.
7
*
-2.
-4.
-6.
-8.
0. 10. 20. 30. 40. 50. 60. 70. 80. 90.
The relationship between the force applied to the pier and the displacement of the deck relative
to the pier obtained herein is depicted in Figure 54 and will be an important framework for the
further considerations in section 6.5.
Earthquake Response and its Control Page 54
0.60
0.40
0.20
0.00
0 20 40 60 80
Max. force in connection deck-pier [MN]
A further important result concerns the deformation of the pylon. The relative displacement
within the pylon is given in Table 9 as d5 , which is the displacement excluding the influence of
the rotation at the pier base as depicted in Figure 42. The deformation in the pylon is 25% larger
for the case of a free deck. This imposes as higher demand on the pylon (cf. the results of push-
over analyses reported in 5.1.2).
The influence of the three earthquake motion components has been investigated on the model
with the free deck (model 1). The aim was to find out whether performing analyses with all 3
earthquake components can be regarded as being on the safe side which is important for further
studies and general design considerations.
Table 10 shows results of maximum displacements obtained for analyses with various
combinations of ground motion components. In this "=0" means that the respective component
is not present and vice versa. The y-component was present in all cases since transverse
displacements were of main interest.
x=0 x=1
y-dspl. deck-ground in span 2 z=0 0.57 0.76
z=1 0.57 0.75
x-dspl. deck-ground at pier M3 z=0 0.00 0.57
z=1 0.00 0.57
y-dspl. deck-ground at pier M3 z=0 0.66 0.80
z=1 0.67 0.81
y-dspl. deck-ground in span 3 z=0 0.61 0.96
z=1 0.59 0.93
y-dspl. pylon top M3 - gound z=0 2.40 2.41
z=1 2.40 2.41
x-dspl. in soil at pier M3 z=0 0.00 0.40
z=1 0.00 0.40
y-dspl. in soil at pier M3 z=0 0.50 0.50
z=1 0.50 0.50
Table 10: Displacements [m] for various combinations of earthquake
components, y-component is always present, model 1 (free deck)
Earthquake Response and its Control Page 55
Firstly, the vertical (z-) component appears to be of minor importance thus suggesting to be
negligible as far as transverse displacements are concerned. However, it should be noted that
nonlinear cable effects arising from the cable sag have not been taken into account. The stiffness
of the cable is unaltered until the strain reaches zero. In reality the effect of cable sag would
already reduce the stiffness of the cables for tensile strains thus probably leading to higher
transverse displacements in the case of an upwards moving deck. Hence, the results obtained
herein should be used with caution.
The longitudinal (x-) component seems to have a much larger impact on the transverse
displacements. While the tower behaviour remains almost unchanged, the deck displacements
are increased by up to 50%. This can be partly attributed to geometric nonlinearities. However,
investigations on the cable behaviour have shown that several exterior cables of the respective
cable groups reach zero tensile strains for the peak longitudinal displacements. For longitudinal
displacement in the opposite direction cables on the other side of the tower go slag. This, of
course, significantly decreases the transverse stiffness of the cable groups and apparently gives
rise to high transverse displacements.
Concluding, the use of all earthquake components leads to upper bound solutions and was thus
employed in all analyses discussed subsequently.
6.3.1 Introduction
In the preceding section results have been presented for two basic systems in terms of
displacements and forces. It is of course inevitable to derive criteria for the assessment of these
results. Whether deck displacements of 95cm are acceptable needs to be discussed as well as
what forces can be applied to the towers by deck restrainers. These issues will be looked into
subsequently. The aim is to present a set of criteria that could also be applicable to other bridge
structures.
For the case of the Rion-Antirion it was decided to seek a solution which provides a fixed deck
under serviceability conditions, thus avoiding any transverse displacements.
If the deck is fixed in the transverse direction at the piers, relative transverse displacements
between piers cause permanent forces on the deck as well as on the towers. This favours deck
connection solutions that can accommodate certain relative displacements as described in 6.4.
Since the pylons are fragile members that are designed to resist high forces, pounding of the
deck against the pylon legs should be avoided under any circumstances. If the deck is smashed
against the pylon leg, extremely high impact forces act on these. Since pylon legs are usually
hollow sections designed for bending and axial forces, local buckling can occur and jeopardise
the overall stability of the pylons.
In the case of the Rion-Antirion Bridge the clear distance between the deck and the pylon legs is
about 80 cm on either side. This should, however, not be the design limit for deck displacements
since the space can be increased in the vicinity of the pylons.
Under earthquake conditions high deformations in the underlying soil can occur. For structures
on particularly weak soil there will be concern as to how large the deformations will be during
an earthquake because the degree of plastisation affects the post-earthquake performance of the
soil bed.
The soil investigations for the Rion-Antirion Bridge project have not yet been finalised. Limits
can therefore not be defined. However, displacements in excess of approximately 40cm could be
critical.
In section 5.1.2 static push-over analyses on the pylons of the Rion-Antirion Bridge were
presented. It is clear from these that the deformation capacity of the pylons is limited and that
yielding in the pylons is an important design factor.
As an approximation, the results of the static push-over analyses can be used to comment on the
displacements obtained from dynamic linear-elastic analyses. There is of course a discrepancy
between the displacements because the linear-elastic analysis neglects changes in stiffness, but
as a rough approximation this still enables to take nonlinearities into account.
For the dynamic analyses a wall thickness of 60cm was used for the pylon leg box section.
Figure 44 shows, that for such a system first cracking occurs at a relative transverse displace-
ment of 30cm, first hinging occurs at 38cm. These are upper bound values while conditions are
much more unfavourable for diagonal loading. This rises the question of the interaction of the x-
and y-components of the pylon deformation. For the case of the free deck which has in 6.2.3
been identified as most unfavourable, these components are plotted in time in Figure 55.
Earthquake Response and its Control Page 57
Although the x-deformations are smaller, the peaks of these can occur at the same time as for
the y-direction and thus increase the danger for the pylon. The closer the resultant is to an angle
of 45 the more unfavourable is the situation. This is because the diamond-shaped pylons have
less ductility and deformation capacity in the diagonal direction. This should be taken into
account when interpreting the results.
0.20
0.10
0.00
-0.10 0 10 20 30 40
-0.20
-0.30
-0.40
-0.50
Time [s]
Figure 55: Free deck model, x- and y-components of d5 (dspl. in the pylon
excluding rotation)
If the deck is somehow connected to the piers, forces will be applied to the towers by the deck.
These depend on the type of connection and the upper bound of the force has been evaluated in
section 6.2.3 as 64MN.
It is obvious that the force that is applied to the towers by the deck should be kept at small as
possible. High interaction forces could not only impose a higher structural demand on the piers
but also increase the demand on the foundation. However, the piers themselves are usually
strong members and the maximum acceptable force may depend on other considerations. For
example, if damping devices are used between deck and pier, the force might have to be limited
for stability reasons of the pistons.
Even during an exceptional event like an earthquake, the safety of the cars passing the bridge
should be ensured. This not only means to avoid the collapse of the structure but also to make
sure that cars are not driven down from the bridge. Usually bridges are equipped with crash
barriers that can also serve in the case of an earthquake. However, it is interesting to know if
there is actually the possibility of the cars starting to slide on the road. Therefore, a method to
investigate this has been developed here and is discussed subsequently. It should be mentioned,
however, that the implications of this study are not at all straightforward and that further
research would be necessary to evaluate the safety of the cars in the case of an earthquake.
Herein it has neither been inspected for how long and far the cars are sliding and when the
wheels will get grip again, nor what corrective actions could be employed by the driver during
successive sliding events.
Earthquake Response and its Control Page 58
The situation of a car moving on a displaced bridge deck is depicted in Figure 56. Rotations of
the deck about the x-axis are taken into account as well as transverse and vertical accelerations
of the deck.
z
x
y
G
N av
ah
H G
H1 R
N
The force that has to be transmitted via friction between the street and the tyre is composed of
the component of the weight in the direction of the deck and the component of the horizontal
inertia force in the direction of the deck:
H = H 1 + Ma h cos (4)
because positive rotations about the x-axis mean inclinations in negative y-direction.
In these Geq is an equivalent weight taking the influence of the vertical acceleration of the deck
into account. Because G is reduced for a deck moving downwards, Geq is given as:
Geq = M ( g + a v ) (7)
This yields
H = M ( g + a v ) x + Ma h . (8)
Earthquake Response and its Control Page 59
The friction resistance against sliding can be written as a simple Coloumb-type relationship:
R = Nc (9)
( g + a v ) c = a h ( g + av )x . (11)
To calculate the safety against sliding the following expression can be employed:
( g + a v )c
s = . (12)
a h ( g + a v ) x
The value s and its development in time can give an impression about the likelihood of cars
sliding on the bridge deck.
The friction coefficient c can be up to 1.0 for optimum conditions. For a wet road surface typical
values are 0.6-0.7. A value of 0.6 has been employed in this study.
Analyses on the value s have been carried out for the basic systems discussed in section 6.2.
The time-histories of this parameter have been monitored in the middle of spans 2 and 3 and at
the tower M3. The absolute minima obtained are given in Table 11.
Apparently the accelerations in the case of a fixed deck are such that sliding is much more likely
to occur. A free deck seems to be favourable. Also the vertical (z-) component seems has a small
unfavourable influence. The safety is increased if no vertical motion is present.
The fuse acts as a shear key under loads that correspond to wind and traffic impact. If forces
exceed a certain limit, the fuse device is broken and gives the deck free. It can be combined with
other devices so as to hand the earthquake behaviour law of the connection over to another
mechanism like a damping device.
F
fuse rupture point
The behaviour of a shock transmitter is similar to a damping device in the sense that the force in
the device depends on the velocity. While extremely slow movements do not cause any forces,
faster movements like wind and traffic impact are responded to by suppressing the
displacements almost rigidly.
F = C v . (13)
Earthquake Response and its Control Page 61
Hence, the force output depends on the velocity. Figure 58 shows the influence of the parameter
on the behaviour.
Constitutive laws for dampers - F =3MN*v
8
7 alpha=0.1
alpha=0.2
6
alpha=0.3
Force F [MN]
5 alpha=0.4
4
3
2
1
0
0 1 2 3 4 5 6
Velocity v [m/s]
Although hydraulic dampers do not have a maximum reaction force, the increase in force
becomes very small for high velocities. This is more pronounced for small values of as can be
seen in Figure 58. Hence, there is actually a limitation on the force that the damping device can
react with.
The energy absorbed by the hydraulic device is mainly released as heat. There is always a
limiting temperature up to which the correct behaviour is ensured. It is thus important to know
about the energy that is dissipated in the device. However, it is difficult to calculate the
temperature thus caused.
For devices which could be used for the bridge discussed herein full-scale dynamic testing is not
possible. Usually tests are then performed for the maximum stroke and reduced speed on one
hand and for maximum force and speed at a reduced stroke on the other hand.
d
Figure 59: Behaviour of elasto-plastic isolator
Elasto-plastic isolators show linear elastic response up to a yield point. The plastic behaviour
can be either ideally plastic or hardening. These dampers can be made of steel as investigated in
this report and the yield point is easily adjusted by designing the device accordingly. If steel
with a hardening branch is used the hysteresis loops are arrived at by using the constitutive law
from Figure 59 and kinematic hardening. Reduction of energy dissipation capacity due to
Bauschinger effect may be considered.
6.5.1 Introduction
The studies in the previous sections have indicated that there is room for considerations
regarding possible damping devices for the deck of the Rion-Antirion Bridge. For a free deck
displacements during an earthquake are rather large (0.95m) so that pounding could occur.
Particularly if tectonic movements preceded, these add to the dynamic displacements.
Transverse displacements can thus considerably exceed 1m. Also, deformations in the soil are
large for a free deck (0.50m). Perhaps most importantly, the deformation demand on the pylons
is very large in the case of a free deck so that yielding can occur. On the other hand, a fully
restrained deck applies high forces to the towers (64MN). Also, the safety of cars against sliding
on the surface is reduced.
The aim of the studies was to investigate the influence of different isolation devices on the
response of the bridge and to shed light on the question which device properties are of major
influence and whether there is an optimum solution.
6.5.3 Results
Herein only the most important results obtained can be presented. For a comprehensive
summary of all the values, the reader is referred to the appendix of this report.
Earthquake Response and its Control Page 64
Table 14 shows the maximum values of certain displacements that were obtained in the
analyses. As can be seen from these, the relative displacements between deck and pier are
considerably reduced as result of using damping devices. Also, as Figure 60 shows exemplary,
the cyclic amplitudes are decreased. Change in sign does only occur once. There are residual
displacements after the earthquake which diminish very slowly.
0.2
0.0
-0.2
-0.4
-0.6
-0.8
0. 5. 10. 15. 20. 25. 30. 35. 40. 45. 50. 55. 60.
Figure 60: Transverse displacements [m] of the deck relative to the pier M3,
model 1 (hydraulic dampers #7, C=12MN, =0.2)
Earthquake Response and its Control Page 65
Figure 61 shows the hysteresis loops that the damping device undergoes. There is, apparently,
high energy dissipation in the device. Particularly the first cycles are very large. Since the
maximum velocity is greater than 1m/s the forces in the damper exceed the value of C. For the
case below the maximum force is 13.1MN. The maximum forces in the device for the other
cases are given in Table 15.
Hysteresis for the damping device, C=12 MN, alpha=0.2 (0-40s only)
15
10
5
Force [MN]
0
-0.70 -0.60 -0.50 -0.40 -0.30 -0.20 -0.10 0.00 0.10 0.20
-5
-10
-15
Displacement [m]
Figure 61: Hysteresis loops of the damping device (hydraulic dampers #7,
C=12MN, =0.2)
This rises the question of the relationship between the displacements that the isolation device
sustains and the forces that are thus applied on the pier. These are depicted in Figure 62 for all
investigated hydraulic damping devices. Clearly, there is a tendency towards smaller
displacements for higher forces applied. However, the influence is surprisingly small. Increasing
the maximum force and therefore the demand on the piers by a factor of 8 leads to a reduction in
displacements by just 30%. Even more interestingly, there seem to be solutions that are more
effective than others. For example, the isolator 12MNv 0.1 reaches a max. displacement of 77cm
at a force of 12.9MN while the 12MNv 0.2 reduces the displacements to 60cm at an almost equal
13.1MN.
Earthquake Response and its Control Page 66
0.80
0.60
0.50
0.40
0.30
0.20
0.10
0.00
0 5 10 15 20 25 30
Max. force in the damper
Figure 62: Relationships max. force [MN] - max. displacement [m] in the
isolation device, hydraulic dampers
In Table 14 also the maximum values of d5 , the relative transverse displacement in the pylon
without the rotation contribution (cf. Figure 42) are given. These correspond to the demand on
the pylons and are thus of particular interest. Figure 63 shows the displacement response of the
bridge pylon M3, giving the absolute displacement within the pylon as well as d5 . Apparently,
the rotation contributes significantly to the displacement response which can also be seen from
the corresponding displaced shape for the maximum displacement in Figure 64. Also, the tower
seems to mainly respond in its fundamental mode. Similar results have been obtained for other
times as well as for all other cases studied.
0.50
0.00
-0.50 0 10 20 30 40 50 60
-1.00
-1.50
-2.00
Time [s]
Figure 63: Relative displacements [m] in the pylon M3, including and
excluding rotations (hydraulic dampers #7, C=12MN, =0.2)
Earthquake Response and its Control Page 67
200
150
100
50
0
-0.50 0.00 0.50 1.00 1.50 2.00
The maximum values of d5 obtained for the certain isolation devices are rather similar and the
differences seem not to be correlated to any particular parameter. Importantly, they are all
smaller than the displacements for the free deck as well as for the fixed deck system. This means
that an essential improvement regarding the demand on the pylon can be achieved by employing
isolation devices between deck and tower. However, for displacements of approximately 30cm
slight cracking in the tension legs may occur according to the results given in section 5.1.2.
Displacements in the soil are hardly affected by the damping device used. Deformations are
approximately 41cm for most of the hydraulic devices.
The value of safety against sliding of cars s as derived in 6.3.4.3 has been studied for 5 cases.
The value has been monitored in the middle of the second and third span as well as at tower M3.
The absolute minimum values are shown in Table 16 and exemplary the time-history of s at
tower M3 is plotted in Figure 65.
0 10 20 30 40 50 60 70 80 90
In all cases apart from the weakest damper the factor becomes smaller than unity and therefore
accelerations are so that sliding can actually occur. It can be inferred from the table that stronger
dampers cause an increase in the accelerations and therefore increase the danger of cars loosing
grip with the surface. The results also well correspond to the values obtained for the cases
studied in 6.2. For the case of a free deck the minimum safety is 0.95 and for a fixed deck the
factor is reduced to 0.21.
It should be noted, that for the hydraulic dampers all the minima obtained and given in Table 16
correspond to the deck at the tower M3, the point where the dampers act.
As can be seen from the time-history in Figure 65, the peaks are very short. Hence, only
momentary sliding occurs and corrective actions by the driver should be possible. This points
out that the danger for the traffic is not as big as could be concluded from the numbers.
Elasto-plastic isolation devices have been studied as outlined in section 6.5.2. For the post-yield
branch hardening has been used as well as perfectly plastic behaviour. Hardening, if employed,
is kinematic.
Firstly, the displacements between bridge deck and pier, meaning the displacements in the
dampers, seem to be well correlated to the yield strength and initial stiffness of the isolators.
Higher yield forces as well as higher initial stiffnesses reduce the displacements. Also, isolators
with a hardening behaviour show smaller displacements then corresponding perfectly plastic
devices.
The residual displacements after the earthquake are also smaller than for the hydraulic device.
0.40
0.20
0.00
0 10 20 30 40 50 60 70 80
-0.20
-0.40
-0.60
-0.80
Figure 66: Transverse displa cements [m] of the deck relative to the pier M3,
elasto-plastic isolators #1, Fy=10MN, Eel=2.1E5 N/mm2 , Epl=0.05Eel
Earthquake Response and its Control Page 70
10
Force [MN]
0
-0.80 -0.60 -0.40 -0.20 0.00 0.20 0.40
-10
-20
-30
Displacement [m]
Figure 67: Hysteresis loops of the device, elasto-plastic dampers #1, Fy=10MN,
Eel=2.1E5N/mm2 , Epl=0.05Eel
The maximum forces in the isolators are given in Table 18. The relationship between the
maximum force and the maximum displacement for all the dampers is depicted in Figure 68.
Leaving the perfectly plastic isolators aside, the relationship is unambiguous. On the other
hand, the perfectly plastic devices can be favourable, as is obvious from the diagram.
Particularly a very stiff non-hardening isolator considerably reduces the displacements while
having the same maximum force. It is this because of the higher energy dissipation capacity
compared to a hardening device with the same maximum force.
0.7
Max. rel. displacement deck - pier
0.6
0.5
0.4 hardening
0.3 perf. plast.
0.2
0.1
0
0 5 10 15 20 25 30 35 40 45
Force in damper [MN]
Figure 68: Relationships max. force [MN] - max. displacement [m] in the
isolation device, elasto-plastic isolators
Earthquake Response and its Control Page 71
In terms of deformations of the pylon the displacements d5 (relative displacement between pylon
top and pylon base excluding rotational contribution) are given in Table 17. Figure 69
exemplary shows a time-history of the d5 values. Again, it is apparent that the rotation at the pier
head strongly contributes to the displacements at the top as can also be seen from the deformed
shape of the pylon shown in Figure 70.
Figure 69: Relative displacements [m] in the pylon M3, including and
excluding rotations, elasto-plastic isolators#1, Fy=10MN,
Eel=2.1E5N/mm2 , Epl=0.05 Eel
250.00
200.00
150.00
100.00
50.00
0.00
-0.50 0.00 0.50 1.00 1.50 2.00 2.50
For the isolation devices studied the deformations in the pylon are very uniform with a value of
31cm. The selection of the device parameters is therefore not governed by this consideration.
The displacements in the pylon are considerably reduced with respect to the case of a free deck
and only slight cracking in the tension legs needs to be expected.
The deformations in the soil springs are larger than for the hydraulic dampers studied and the
case of a fixed deck. However, with approximately 44cm they are still smaller than for the case
of a free deck.
Also for the case of the elasto-plastic dampers the factor of safety against sliding of cars s has
been investigated. The absolute minima found are given in Table 19, an exemplary time-history
plot is shown in Figure 71.
0 10 20 30 40 50 60 70 80 90
As has already been found for the hydraulic dampers, sliding of cars can occur. Also for the
elasto-plastic dampers there is a trend towards lower safety for stronger dampers which can be
attributed to higher accelerations of the deck. Again, sliding does only occur momentarily and
should thus not impose a high danger on the traffic.
Earthquake Response and its Control Page 73
6.6 Conclusions
The earthquake behaviour of the Rion-Antirion Bridge has been studied for various configura-
tions. The cases of a transversely free and a restrained deck have been considered as well as
possible isolation devices.
In the light of the set of performance criteria described in 6.3 the following can be concluded
from the results obtained for earthquake conditions.
- relative displacements between deck and pier are too large, particularly if transverse
tectonic movements precede;
- accelerations of the deck are such that sliding of cars can occur.
- the deformation demand on the pylon is considerably reduced by any device studied
- deformations in the soil are reduced with respect to a free deck configuration;
hydraulic devices are more efficient
- forces on the pier are reduced with respect to a fixed connection and can be adjusted
by choosing the appropriate device
- accelerations of the deck can be reduced with some dampers; the likelihood of cars
sliding on the deck can thus be reduced.
Table 20 shows a comparison of possible solutions for the deck connection. It is apparent that
damping devices provide a good solution with results lying either between a free and a fixed
deck or even being more favourable than both as for the deformation demand on the pylon.
Earthquake Response and its Control Page 74
If an optimal solution in terms of deck displacements and pier forces is sought, Figure 72 gives
an interesting relationship. The devices studied seem to lie close to the straight line between the
results for a free and a restrained deck. This means that the damping device can to a certain
extent be adjusted to the response that is required. If lower deck displacements are sought higher
forces on the pier need to be accommodated and vice versa. However, there are more and less
effective solutions as has already been pointed out in section 6.5. While displacement reduction
seems to depend on the energy dissipation capacity of the isolator the maximum force is
correlated to the strength of the device.
As was explained earlier, for the design of the deck configuration serviceability conditions also
need to be considered. If wind induced deck movements shall be avoided, a fuse device can be
employed as explained in 6.4.1. Also, the impact of slow tectonic movements needs to be taken
into account. In the case of the Rion-Antirion Bridge these are required so as not to cause
Earthquake Response and its Control Page 75
additional forces in the structure. Therefore, a so called shock transmitting device as described
in section 6.4.2 needs to be employed.
If all the above mentioned requirements are taken into account, a possible deck configuration
featuring a fuse, a shock transmitter and isolation devices could look as shown in Figure 73 and
Figure 74.
7 SUMMARY
The main objective of this dissertation was to study the seismic behaviour and performance of
cable-stayed bridges. To this end, investigations on the Rion-Antirion Bridge structure were
conducted employing the finite element method. With the three-dimensional model and the
analysis code used it was possible to take into account all major member characteristics and
boundary conditions as well as geometric nonlinearities.
As a first step static analyses were conducted on the bridge subjected to relative displacements
between the piers to study the impact of tectonic movements on the structure. It was found that
the flexibility of the bridge which is provided by a freely movable deck acts favourably in terms
of induced forces. The bridge deck responds by considerable relative displacements with respect
to the pylons which can, however, be disadvantageous if deck displacements need to be limited.
Displacements of preceded tectonic movements add to the dynamic displacements during an
earthquake and can thus increase the danger for pounding of the deck against the pylon legs.
Modal analyses were performed to investigate the basic dynamic characteristics of the bridge.
Four different cases in terms of deck connectivity were considered and the following
conclusions can be drawn:
- The fundamental mode has a very long period. It is either a transverse (18.6s) or a
vertical deck (7.5s) mode depending on whether the deck is free in the transverse
direction or not. Several well spaced long period modes follow succeeded by many
closely spaced modes below 3s.
- Tower modes have a high mass participation. These are beyond mode no. 100 which
points out the importance of higher mode contribution.
- For the shape and the natural frequency of the long period modes the boundary
conditions of the deck are most influential.
To study the seismic behaviour of the bridge a framework of performance criteria was set up
considering the following parameters:
- forces: forces in the pylon (results of static push-over analyses were utilised), forces
on the piers from the deck connection system;
- accelerations of the deck: sliding of cars on the road surface was considered.
Dynamic time-history analyses were performed to study the bridge response to a design
earthquake. A set of significant response parameters was monitored and commented on. Firstly,
the basic structural configurations with a free and a fully restrained deck were investigated.
Summary Page 77
Then it was analysed whether the seismic performance can be improved by employing isolation
devices between the deck and the pylon base. To this end, parametric studies with 13 hydraulic
dampers and 9 elasto-plastic devices were conducted. The following was found:
- Relative displacements of a free deck are very large. These can be limited by using
isolation devices. However, this gives rise to additional forces applied on the piers.
A straightforward relationship was found between these forces and the maximum
displacements. By choosing the appropriate isolation device it is thus possible to
adjust the bridge response as desired. It was, however, also found that, depending on
the energy dissipation capacity with respect to the maximum force, the effectiveness
of the devices varies.
- The deformation demand on the pylon was found to be considerably reduced by any
of the damping devices. Only slight cracking on the legs needs to be expected in that
case.
- Soil deformations are largest for the system with a free deck and smallest for a
restrained deck. Isolation devices provide an intermediate solution.
In the light of the framework of performance criteria it can be concluded that by applying deck
isolation devices the earthquake behaviour of cable-stayed bridges can be significantly
improved. An optimum performance with these passive devices can be obtained by balancing
the reduction in forces along the bridge against tolerable displacements. It was also shown
which device properties provide the most efficient solutions.
Further investigations are necessary to substantiate the results obtained. Parametric studies on
the soil properties and the input motion were beyond the scope of this work. Also, modelling
approaches for the foundation and the cables could be improved by enhanced soil-structure
interaction modelling and nonlinear cable models respectively. Most importantly, it should be
noted, that only one particular structure has been studied. Since every cable-stayed bridge is an
individual structure with respect to all its characteristics, also the effect of changes in geometry
should be looked into. Not only have these an influence on the basic dynamic properties but also
the effectiveness of isolation devices as proven herein could be altered.
References Page 78
8 REFERENCES
[7] ADINA System 7.2, 1998, ADINA R&D, Inc., 71 Elton Avenue,
Watertown, MA 02472, USA
[11] Alireza, R., G. Amin, "An investigation into the effect of earthquake
on bridges", Proceedings of the 10th World Conference on
Earthquake Engineering, Madrid, 1992, pp. 4763-4766
[13] Ambraseys, N.N., J.A. Jackson, "Seismicity and strain in the gulf of
Corinth (Greece) since 1694, Journal of Earthquake Engineering,
Vol. 1, No. 3, 1997, pp. 433-474
[34] Ernst, H.J., "Der E-Modul von Seilen unter Bercksichtigung des
Durchhngens", Bauingenieur, Vol. 40, 1965, pp. 52-55
[50] Gimsing, N.J., "Cable supported bridges - concept & design", John
Wiley, 2nd edition, 1998
[52] Gupta, S.P., Kumar, A., "A study on dynamics of cable stayed bridge
including foundation interaction", Proceedings of the 8th European
Conference on Earthquake Engineering, Lisbon, 1986, Vol. 5, pp.
8.3/9-8.3/16
[65] Khalil, M.S., "Seismic analysis and design of the skytrain cable-
stayed bridge", Canadian Journal of Civil Enginering, Vol. 23, pp.
1241-1248, 1995
References Page 84
[68] Loo, Y.-C., G. Iseppi, "Nonlinear effects of cable sag - a case study",
Proceedings of the International Conference on Cable-Stayed
Bridges, Bangkok, 1987, Vol. 1, pp. 289-303
[72] Naeim, F., J.M. Kelly, "Design of Seismic isolated structures: from
theory to practice", John Wiley, 1999
[80] Priestley, M.J.N., G.M. Calvi, "Concepts and procedures for direct
displacement-based design", Seismic Design Methodologies for the
Next Generation of Codes, Fajfar, P., H. Krawinkler (eds.), Balkema,
1997, pp. 171-181
[88] Tuladhar, R., D.M. Brotton, "A computer program for non-linear
dynamic analysis of cable-stayed bridges under seismic loading",
Proceedings of the International Conference on Cable-Stayed
Bridges, Bangkok, 1987, Vol. 1, pp. 315-326
[89] Vaz, C.T., A. Rito, R.T. Duarte, "Seismic studies of the Arade river
cable-stayed bridge", Proceedings of 9th World Conference on
Earthquake Engineering, Tokyo-Kyoto, 1988, Vol. 6, pp. 507-512
[97] Woo, G., "Long period earthquake risk in Europe", Fifth SECED
Conference - European Seismic Design Practice, Elnashai (ed.),
Balkema, 1995, pp. 59-65
[105] Zhang, X.-L., X.-Y. Yan, "A method for evaluating earthquake
resistant behaviour of bridge", Proceedings of the 10th World
Conference on Earthquake Engineering, Madrid, 1992, pp. 4827-
4831
[107] Zienkiewicz, O.C., R.L. Taylor, "The Finite Element Method", 4th
edition, Vol. 1,2, 1991, Mc Graw Hill