You are on page 1of 64

INSTRUCTION MANUAL

VHF TRANSCEIVER

iV80
iV80E

This device complies with Part 15 of the FCC Rules. Operation


is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.

WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE


C E L L U L A R R A D I OT E L E P H O N E S E RV I C E S I G N A L S I S
PROHIBITED UNDER FCC RULES AND FEDERAL LAW.
FOREWORD EXPLICIT DEFINITIONS
Thank you for purchasing this fine Icom product. The IC-V80/ WORD DEFINITION
V80E vhf transceiver is designed and build with Icoms su-
Personal death, serious injury or an ex-
perior technology and craftsmanship. With proper care, this R DANGER!
plosion may occur.
product should provide you with years of trouble-free opera-
tion. Personal injury, fire hazard or electric
R WARNING!
shock may occur.
We want to take a couple of moments of your time to thank CAUTION Equipment damage may occur.
you for making your IC-V80/V80E your radio of choice, and Recommended for optimum use. No risk
NOTE
hope you agree with Icoms philosophy of technology first. of personal injury, fire or electric shock.
Many hours of research and development went into the de-
sign of your IC-V80/V80E.

FEATURES IMPORTANT
Dust-protection/Splash-resistant construc- READ ALL INSTRUCTIONS carefully and completely
tion (IP54*) before using the transceiver.
*Only when the battery pack/case, antenna and jack cover are SAVE THIS INSTRUCTION MANUAL This in-
attached.
struction manual contains important operating instructions
for the IC-V80/V80E.
Built in VOX circuit enabling the VOX op-
eration* (voice operated transmission)
*To use the VOX operation, an optional headset and a plug
adapter cable are additionally required.


PRECAUTIONS
RWARNING RF EXPOSURE! This device emits NEVER connect the transceiver to a power source using
Radio Frequency (RF) energy. Caution should be observed reverse polarity. This will ruin the transceiver.
when operating this device. If you have any questions re-
garding RF exposure and safety standards, please refer to DO NOT operate the transceiver near unshielded electri-
the Federal Communications Commission Office of Engi- cal blasting caps or in an explosive atmosphere.
neering and Technologys report on Evaluating Compliance
with FCC Guidelines for Human Radio Frequency Electro- DO NOT push [PTT] unless you actually intend to trans-
magnetic Fields (OET Bulletin 65) mit.

RWARNING! NEVER hold the transceiver so that BE CAREFUL! The transceiver will become hot when
the antenna is very close to, or touching exposed parts of operating it continuously for long periods.
the body, especially the face or eyes, while transmitting. The
transceiver will perform best if the microphone is 5 to 10 cm DO NOT use or place the transceiver in direct sunlight
(2 to 4 inches) away from the lips and the transceiver is ver- or in areas with temperatures below 20C (4F) or above
tical. +60C (+140F).

RWARNING! NEVER operate the transceiver with Place the unit in a secure place to avoid inadvertent use by
a headset or other audio accessories at high volume levels. children.
Hearing experts advise against continuous high volume op-
eration. If you experience a ringing in your ears, reduce the DO NOT use harsh solvents such as benzene or alco-
volume level or discontinue use. hol to clean the transceiver, because they can damage the
transceivers surfaces.
RWARNING! NEVER operate the transceiver while
driving a vehicle. Safe driving requires your full attention
anything less may result in an accident.

ii
PRECAUTIONS FCC INFORMATION
KEEP the transceiver away from heavy rain, and never FOR CLASS B UNINTENTIONAL RADIATORS:
immerse in the water. The transceiver meets IP54* require- This equipment has been tested and found to comply with
ments for dust-protection and splash resistance. However, the limits for a Class B digital device, pursuant to part 15 of
once the transceiver has been dropped, dust-protection and the FCC Rules. These limits are designed to provide reason-
splash resistance cannot be guaranteed because of possible able protection against harmful interference in a residential
damage to the transceivers case or the waterproof seal. installation. This equipment generates, uses and can radi-
* Only when the battery pack/case, antenna and jack cover are at- ate radio frequency energy and, if not installed and used
tached. in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
NEVER operate or touch the transceiver with wet hands. guarantee that interference will not occur in a particular in-
This may result in an electric shock or may damage the stallation. If this equipment does cause harmful interference
transceiver. to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
Even when the transceiver power is OFF, a slight current still try to correct the interference by one or more of the following
flows in the circuits. Remove the battery pack or batteries measures:
from the transceiver when not using it for a long time. Oth- Reorient or relocate the receiving antenna.
erwise, the installed battery pack or batteries will become Increase the separation between the equipment and re-
exhausted, and will need to be recharged or replaced. ceiver.
Connect the equipment into an outlet on a circuit differ-
Approved Icom optional equipment is designed for optimal ent from that to which the receiver is connected.
performance when used with an Icom transceiver. Consult the dealer or an experienced radio/TV techni-
Icom is not responsible for the destruction or damage to an cian for help.
Icom transceiver in the event the Icom transceiver is used
with equipment that is not manufactured or approved by
CAUTION: Changes or modifications to this device, not
Icom.
expressly approved by Icom Inc., could void your authority
to operate this device under FCC regulations.
iii
SUPPLIED ACCESSORIES 1
2
The following accessories are supplied with the transceiver.
3
Battery pack* Antenna 4
5
6
Jack cover Belt clip*
(with screws)
7
8
9
10
11
Battery charger* AC adapter* 12
13
14
15
16
Icom, Icom Inc. and the Icom logo are registered trademarks of
Icom Incorporated (Japan) in Japan, the United States, the United 17
Kingdom, Germany, France, Spain, Russia and/or other countries.
* Not supplied, or the shape is different, 18
depending on the version. Microsoft, Windows and Windows Vista are registered trademarks of
Microsoft Corporation in the United States and/or other countries.
19
iv
TABLE OF CONTENTS
FOREWORD...................................................................................... i Monitor function......................................................................14
FEATURES......................................................................................... i Mode selection.......................................................................15
EXPLICIT DEFINITIONS.................................................................... i Operating mode selection.......................................................16
IMPORTANT....................................................................................... i Setting a tuning step...............................................................16
PRECAUTIONS.............................................................................iiiii Setting a frequency.................................................................16
FCC INFORMATION........................................................................ iii Receiving................................................................................17
SUPPLIED ACCESSORIES............................................................. iv Transmitting.............................................................................17
TABLE OF CONTENTS................................................................ vvi Key lock function.....................................................................18
[VOL] function assignment......................................................18
1 ACCESSORIES............................................................12 Weather channel operation (U.S.A. version only)...................19
Antenna....................................................................................1
Belt clip.....................................................................................1 5 REPEATER AND DUPLEX OPERATION................2023
Battery pack/case.....................................................................2 Repeater operation.................................................................20
Jack cover.................................................................................2 Duplex operation.....................................................................21
Subaudible tones....................................................................22
2 PANEL DESCRIPTION.................................................37 Lockout function......................................................................23
.. Front, top and side panels........................................................3 Auto repeater function (U.S.A. version only) ..........................23
Function display........................................................................6
6 MEMORY/CALL OPERATION.................................2428
3 BATTERY CHARGING...............................................813 General description................................................................24
Caution (for the BP-264 Ni-MH battery).................................... 8 Selecting a memory channel..................................................24
Caution (for the BP-265 Li-Ion battery).....................................9 Selecting the Call channel......................................................24
Battery chargers.....................................................................11 Channel programming............................................................25
Battery case (BP-263)................................................................ 13 Copying memory/Call contents...............................................26
Battery information.................................................................13 Clearing memory contents..............................................................27
Display type............................................................................27
4 BASIC OPERATION.................................................1419 P  rogramming a channel name..................................................28
Power ON...............................................................................14
Adjusting the volume level......................................................14
Adjusting the squelch level.....................................................14


TABLE OF CONTENTS 1
2
7 SCAN OPERATION..................................................2931 13.................
TROUBLE SHOOTING...................................................50
Scan types..............................................................................29 3
.. Programmed scan .................................................................29 14 OPTIONS..................................................................5153
Memory Scan.........................................................................30 VOX function...........................................................................52 4
Setting skip channels..............................................................30
15 SPECIFICATIONS..........................................................54
5
Scan resume setting...............................................................30
Priority watch..........................................................................31 6
16 CE.............................................................................5556
8 TONE SQUELCH AND POCKET BEEP..................3234 7
Tone/DTCS squelch and pocket beep.....................................32
Tone scan...............................................................................34
8
9
9 DTMF MEMORY.......................................................3537
Programming a DTMF code sequence...................................35 10
Transmitting a DTMF code sequence.....................................36
Confirming a DTMF memory..................................................37 11
Setting DTMF transfer speed..................................................37
12
10 SET MODES.............................................................3847 13
Set mode programming..........................................................38
Set mode items.......................................................................39 14
Initial Set mode programming................................................... 43
Initial Set mode items.............................................................44 15
11 CLONING.......................................................................48
16
Cloning operation....................................................................48 17
12 RESETTING...................................................................49 18
Resetting................................................................................49
19
vi
1 ACCESSORIES

Antenna Belt clip


Insert the antenna into the antenna connector and twist the To attach the belt clip:
antenna to lock it in place. Slide the belt clip in the direction of the arrow until the belt
clip locks in place, and makes a click sound.
Belt clip

Battery pack/case

To detach the belt clip:


q Remove the battery pack/case from the transceiver, if it is
CAUTION:
attached. (p. 2).
NEVER HOLD just the antenna when carrying the trans-
w Lift the tab up (q), and slide the belt clip in the direction
ceiver.
of the arrow (w).
Transmitting without an antenna will damage the trans-
ceiver. w
q


ACCESSORIES 1

Battery pack/case NEVER remove or attach the battery pack/case when the
transceiver is wet or soiled. This may result in water or
1
To attach the battery pack/case: dust getting into the transceiver/battery pack/case, and 2
may result in them being damaged.
q Fit the battery pack/case in the direction of the arrow (q), 3
then close. NOTE: Keep the battery terminals clean. Its a good idea
w Hook the latch until it makes a click sound (w). 4
to clean the battery terminals once a week.
q 5
Battery pack/case Jack cover 6
7
Attach the jack cover when optional equipment is not used.
w 8
To attach the jack cover To detach the jack cover
Latch q A ttach the jack cover to e Remove the screws with a 9
the [SP MIC] jack. phillips screwdriver.
w Tighten the screws. r D etach the jack cover to
10
To remove the battery pack/case: connect optional equip- 11
ment.
Be careful! The latch is tightly locked, so use caution 12
when releasing it. DO NOT use your finger nail. Use the
edge of a coin or screwdriver tip to carefully release it. 13
U
 nhook the latch (e), and lift up the battery pack/case in e 14
the direction of the arrow (r). w
q 15
e r
r 16
w
17
18
19
e

2 PANEL DESCRIPTION

Front, top and side panels


q PTT SWITCH [PTT]
Push and hold to transmit, release to receive. (p.17)
For IC-V80E only
w e Push briefly, then push and hold to transmit a 1750 Hz
tone burst signal. (p. 22)
w ANTENNA CONNECTOR
Connect the antenna here. (p.1)
Speaker
e CONTROL DIAL [VOL]
q r Adjust the volume level. (p.14)
Microphone During the Set mode, or Initial Set mode, rotate to se-
lect a desired option or value. (pp.38, 43)
Function
display (p. 6) r EXTERNAL SPEAKER/MICROPHONE JACKS [SP MIC]
Used to connect an optional speaker-microphone, plug
t adapter cable or cloning cable. The internal microphone
y and speaker will not function when an option is con-
u nected. See page 51 for a list of available options.
Keypad (p. 4)  Be sure to turn power OFF before connecting/discon-
necting optional equipment to/from the [SP/MIC] jack.
i
t MONITOR KEY [MONI]
Push and hold to open the squelch temporarily to mon-
itor the operating frequency. (p.14)
While pushing and holding this key, push [] or [] to
adjust the squelch level. (p.14)
Enters or sends the DTMF code A. (pp.35, 36)


PANEL DESCRIPTION 2

y POWER KEY [ ] D KEYPAD 1


Push and hold for 1 sec. to turn the transceiver power ON
or OFF. (p. 14) 2
u UP/DOWN KEYS []/[] 3
Push to change the operating frequency. (p.16) 4
D uring memory mode operation, push to select a
memory channel. (p.24) 5
While scanning, push to change the scanning direction.
6
(pp.29, 30, 31, 34)
W hile pushing and holding [MONI], push to set the 7
squelch level. (p.14)
During the Set mode, or Initial Set mode, push to se-
8
Push to input numbers for frequency input and memory
lect a desired setting item. (pp.38, 43) channel selection. 9
[ ] enters or sends the DTMF code B. (pp.35, 36) Push to enter or send the DTMF code. (pp.35, 36)
[ ] enters or sends the DTMF code C. (pp.35, 36) To activate the second function of a key, first push
10
i VFO/MEMORY/CALL KEY [VFO/MR/CALL] [FUNC](M), and then push the key. 11
Push to select the VFO mode, memory mode, a Call
[1] [ TONE](1)
12
channel and a weather channel*, in sequence. (p.15)
*Only the U.S.A. version transceivers. Numeric input and DTMF code: 1 13
After pushing [FUNC](M), push to enter the memory After pushing [FUNC](M), selects the Tone func-
tion. (p.33) 14
programming mode.
After pushing [FUNC](M), push and hold for 1 sec. to 15
[2] [VOX](2)
transfer a channel contents to a memory channel, or to
the VFO mode. (p. 26)
Numeric input and DTMF code: 2 16
After pushing [FUNC](M), turns the VOX function
E  nters or sends the DTMF code D. (pp.35, 36)
ON or OFF*. (p.52)
17
 The functions of [VOL] and []/[] can be exchanged. * O nly when an optional headset and plug adapter are 18
See page 18 for details. connected.
19

2 PANEL DESCRIPTION

[3] [T.SCAN](3) [9] [H/M/L](9)


Numeric input and DTMF code: 3 Numeric input and DTMF code: 9
A fter pushing [FUNC](M), starts a tone scan. A fter pushing [FUNC](M), selects the output
(p.34) power between high, middle and low. (p.17)

[4] [DUP](4) [0] [DTMF-M](0)


Numeric input and DTMF code: 4 Numeric input and DTMF code: 0
After pushing [FUNC](M), selects minus duplex, A fter pushing [FUNC](M), enters the DTMF
plus duplex, or simplex operation. (p.21) memory mode. (p.35)

[5] [SCAN](5) [M] [FUNC](M)


Numeric input and DTMF code: 5 DTMF code: M (indication: E)
After pushing [FUNC](M), starts a scan. (pp.29, Push to access the second function of other keys.
30)
[# ENT] [ ](# ENT)
[6] [SKIP](6) DTMF code: # (indication: F)
Numeric input and DTMF code: 6 After entering a frequency, stores the frequency.
A fter pushing [FUNC](M), sets or cancels the (p.16)
skip setting. (p.30) P ush to exit the Set mode or Initial Set mode.
(pp.38, 43)
[7] [PRIO](7) After pushing [FUNC](M), push and hold for 1 sec.
Numeric input and DTMF code: 7 to turn the key lock function ON or OFF (p.18)
After pushing [FUNC](M), starts a priority watch.
(p.31)

[8] [SET](8)
Numeric input and DTMF code: 8
After pushing [FUNC](M), enters the Set mode.
(p.38)


PANEL DESCRIPTION 2

Function display 1
e TONE INDICATOR 2
qw e r t y
 appears while the repeater tone encoder is ON. 3
(p.20)
u  appears while the tone squelch function is ON. 4
!5 (p.33)
!4
i 5
o D appears while the DTCS squelch function is ON.
!3 (p.33) 6
 appears with the or D indicator while the pocket
!2 !1 !0 beep function (with CTCSS or DTCS) is ON. (p.33)
7
r MEMORY INDICATOR
8
Appears when the memory mode is selected. (pp.15, 24) 9
q BUSY INDICATOR t FREQUENCY READOUT 10
A ppears when a signal is being received, or the D isplays the operating frequency, memory channel,
Set modes contents and a variety of other information. 11
squelch is open.
Blinks while the monitor function is ON. (p.14) The decimal point blinks during scan. 12
D uring memory mode operation, the programmed
w SIGNAL INDICATOR memory name is displayed. 13
Shows the strength of the received signal. (p.17)
y BATTERY INDICATOR (p.13) 14
 (battery indicators) appear when the battery 15
pack/case is attached.
Weak RX Signal level Strong
 appears when the battery pack must be changed, 16
W hile transmitting, shows the output power level. or batteries must be replaced. 17
(p.17)
18
19
Low Middle High

2 PANEL DESCRIPTION

u KEY LOCK INDICATOR


Appears when the key lock function is ON. (p.18)
i VOX INDICATOR
Appears when the VOX function is ON. (p.52)
o POWER INDICATOR (p.17)
H appears when high power is selected.
M appears when middle power is selected.
L appears when low power is selected.
!0 MEMORY CHANNEL NUMBER INDICATOR
Displays the selected memory channel number. (p.24)
C appears when the Call channel is selected. (p.24)
!1 AUTO POWER OFF INDICATOR
Displays when the Auto Power OFF function is ON. (p.44)
!2 DUPLEX INDICATOR (p.21)
+ appears when plus duplex is selected.
 appears when minus duplex is selected.
!3 SKIP INDICATOR
Appears when the selected memory channel is set as a
skip channel. (p.30)
!4 FUNCTION INDICATOR
Appears when the second function can be accessed.
!5 TRANSMIT INDICATOR
Appears while transmitting. (p.17)


BATTERY CHARGING 3
Caution (for the BP-264 Ni-MH battery) Clean the battery terminals to avoid rust or misscontact. 1
R
 DANGER! NEVER short terminals (or charging terminals)
 eep battery terminals clean. Its a good idea to clean bat-
K 2
tery terminals once a week.
of the battery pack. Also, current may flow into nearby metal 3
objects such as a necklace, so be careful when placing bat- If your Ni-MH battery pack seems to have no capacity, even
tery packs (or the transceiver) in handbags, etc. after being charged, completely discharge it by leaving the 4
power ON overnight. Then, fully charge the battery pack again.
Simply carrying with or placing near metal objects such as
If the battery pack still does not retain a charge (or only very lit-
5
a necklace, etc. may cause shorting. This may damage not
only the battery pack, but also the transceiver. tle charge), a new battery pack must be purchased. (p. 51) 6
Prior to using the transceiver for the first time, the battery
R
 DANGER! NEVER incinerate used battery packs. Internal
pack must be fully charged for optimum life and operation.
7
battery gas may cause an explosion.
Recommended temperature range for charging: 8
R
 DANGER! NEVER immerse the battery pack in water.
between +10C and +40C (rapid charge: with BC-191) or 9
If the battery pack becomes wet, be sure to wipe it dry BE-
between 0C and +45C (regular charge: with BC-192)
FORE attaching it to the transceiver.
Use the supplied charger or optional charger (BC-191 for 10
CAUTION: Always use the battery within the specified tem-
perature range, 5C to +60C (+23F to +140F). Using the
rapid charging, BC-192 for regular charging) only. NEVER 11
use other manufacturers chargers.
battery out of its specified temperature range will reduce the 12
batterys performance and battery life. The battery pack contains a rechargeable battery.
 AUTION: Shorter battery life could occur if the battery is
C Charge the battery pack before first operating the trans-
13
left completely discharged, or in an excessive temperature ceiver, or when the battery pack becomes exhausted. 14
environment (above +55C; +131F) for an extended period If you want to prolong the battery life, the following points
of time. If the battery must be left unused for a long time, should be observed: 15
it must be detached from the radio after charging. Keep it Avoid over charging. The charging time period should be 16
safely in a cool dry place at the following temperature range: less than 48 hours.
20C to +45C (4F to +113F) (up to a month)
17
Use the battery pack until it becomes almost completely
20C to +35C (4F to +95F) (up to six months) exhausted, under normal conditions. We recommend bat- 18
20C to +25C (4F to +77F) (up to a year*) tery charging after transmitting becomes impossible. 19
* We recommend charging the battery pack every 6 months.

3 BATTERY CHARGING

Caution (for the BP-265 Li-Ion battery)


Misuse of Li-Ion batteries may result in the following haz- R DANGER! DO NOT expose the battery to rain, snow, sea-
ards: smoke, fire, or the battery may rupture. Misuse can water, or any other liquids. Do not charge or use a wet battery.
also cause damage to the battery or degradation of battery If the battery gets wet, be sure to wipe it dry before using.
performance. R
 DANGER! NEVER incinerate a used battery pack since
internal battery gas may cause it to rupture, or may cause
R
 DANGER! Use and charge only specified Icom battery an explosion.
packs with Icom radios or Icom chargers. Only Icom battery
R DANGER! NEVER solder the battery terminals, or
packs are tested and approved for use with Icom radios or
NEVER modify the battery pack. This may cause heat gener-
charged with Icom chargers. Using third-party or counterfeit
ation, and the battery may burst, emit smoke or catch fire.
battery packs or chargers may cause smoke, fire, or cause
the battery to burst. R
 DANGER! Use the battery only with the transceiver for
which it is specified. Never use a battery with any other
D Battery caution equipment, or for any purpose that is not specified in this in-
struction manual.
R
 DANGER! DO NOT hammer or otherwise impact the bat-
tery. Do not use the battery if it has been severely impacted R
 DANGER! If fluid from inside the battery gets in your
or dropped, or if the battery has been subjected to heavy eyes, blindness can result. Rinse your eyes with clean water,
pressure. Battery damage may not be visible on the outside without rubbing them, and see a doctor immediately.
of the case. Even if the surface of the battery does not show R
 WARNING! Immediately stop using the battery if it emits
cracks or any other damage, the cells inside the battery may an abnormal odor, heats up, or is discolored or deformed. If
rupture or catch fire. any of these conditions occur, contact your Icom dealer or
R DANGER! NEVER use or leave battery pack in areas distributor.
with temperatures above +60C (+140F). High tempera- R
 WARNING! Immediately wash, using clean water, any
ture buildup in the battery, such as could occur near fires part of the body that comes into contact with fluid from in-
or stoves, inside a sun heated car, or in direct sunlight may side the battery.
cause the battery to rupture or catch fire. Excessive temper-
atures may also degrade battery performance or shorten
battery life.

BATTERY CHARGING 3

R
 WARNING! NEVER put the battery in a microwave oven, R
 WARNING! DO NOT charge or leave the battery in the 1
high-pressure container, or in an induction heating cooker. battery charger beyond the specified time for charging. If the
This could cause a fire, overheating, or cause the battery to battery is not completely charged by the specified time, stop 2
rupture. charging and remove the battery from the battery charger. 3
Continuing to charge the battery beyond the specified time
 AUTION: Always use the battery within the specified tem-
C
limit may cause a fire, overheating, or the battery may rup- 4
perature range, 20C to +60C (4F to +140F). Using the
ture.
battery out of its specified temperature range will reduce the 5
batterys performance and battery life. R
 WARNING! NEVER insert the transceiver (battery at-
tached to the transceiver) into the charger if it is wet or
6
 AUTION: Shorter battery life could occur if the battery is
C
left fully charged, completely discharged, or in an excessive soiled. This could corrode the battery charger terminals or 7
temperature environment (above +50C; +122F) for an ex- damage the charger. The charger is not waterproof.
8
tended period of time. If the battery must be left unused for a  AUTION: DO NOT charge the battery outside of the spec-
C
long time, it must be detached from the radio after discharg- ified temperature range: BC-193 (+10C to +40C; +50F 9
ing. You may use the battery until the battery indicator shows to +104F). Icom recommends charging the battery at +20C
10
half-capacity, and then keep it safely in a cool dry place at (+68F). The battery may heat up or rupture if charged out of
the following temperature range: the specified temperature range. Additionally, battery perfor- 11
20C to +50C (4F to +122F) (up to a month) mance or battery life may be reduced.
12
20C to +35C (4F to +95F) (up to three months)
20C to +20C (4F to +68F) (up to a year) 13
14
D Charging caution The supplied battery pack, charger, and AC adapter dif-
R
 DANGER! NEVER charge the battery pack in areas with fer, or no supplied depending on the version. 15
Prior to using the transceiver for the first time, the battery
extremely high temperatures, such as near fires or stoves, 16
inside a sun-heated vehicle, or in direct sunlight. In such en- pack must be fully charged for optimum life and operation.
vironments, the safety/protection circuit in the battery will ac- 17
tivate, causing the battery to stop charging. 18
19
10
3 BATTERY CHARGING

Battery chargers DU
 sing the BC-192 to regular charge the BP-264
The BC-192 provides regular charging of only the BP-264
D Using the BC-191 to rapid charge the BP-264 Ni-MH battery pack. Never use it to charge any other battery
The BC-191 provides rapid charging of only the BP-264 Ni-MH pack.
battery pack. Never use it to charge any other battery pack. Charging time (with the 147S): Approx. 16 hours
Charging time: Approx. 2 hours The following item is additionally required:
An AC adapter (not supplied with some versions) or the OPC-515L
The following item is additionally required:
DC power cable.
An AC adapter (not supplied with some versions) or the OPC-515L
or CP-23L DC power cable. Battery pack Transceiver
AC adapter
AC adapter Battery pack Transceiver
(A different type, or no AC
(A different type, or no AC adapter is supplied, de-
adapter is supplied, de- pending on the version.)
pending on the version.)

Turn power OFF


Turn power OFF
Screws*
Screws* (Self tapping screw:
(Self tapping screw: M3.5 at least 30 mm)
M3.5 at least 30 mm) *Purchase separately.
The optional OPC-
*Purchase separately. Using screws is
515L (for DC power
Using screws is recommended to
source) can be
recommended to secure the charger.
The optional OPC- used instead of the
secure the charger. AC adapter.
515L (for DC power Charge indicator
source) or CP-23L Charging time period differs Lights green while charging.
(for 12 V cigarette Charge indicator depending on the input voltage. NOTE:
lighter socket) can Lights orange : While charging 12 V : Approx. 36 hours The charge indicator will not
be used instead of Lights green : Charging is completed. 13.8 V : Approx. 21 hours go out even after a battery
the AC adapter. 16 V : Approx. 16 hours pack is fully charged.
11
BATTERY CHARGING 3

D Using the BC-193 to rapid charge the BP-265 IMPORTANT: Battery charging caution 1
The BC-193 provides rapid charging of only the BP-265 Li- Ensure the tabs on the battery pack are correctly aligned
Ion battery pack. Never use it to charge any other battery with the guide rails inside the charger. 2
pack. Tabs 3
Charging time: Approx. 2.5 hours
4
The following item is additionally required:
An AC adapter (not supplied with some versions) or the OPC-515L 5
or CP-23L DC power cable. 6
AC adapter Battery pack Transceiver
(A different type, or no AC 7
adapter is supplied, de-
pending on the version.) 8
Guide rail
9
CAUTION: When using the OPC-515L DC power cable 10
NEVER connect the OPC-515L to a power source using 11
reverse polarity. This will ruin the battery charger.
Turn power OFF White line: + Black line: 12
Screws*
13
(Self tapping screw:
M3.5 at least 30 mm)
14
*Purchase separately. 15
Using screws is
recommended to
secure the charger.
16
The optional OPC-
515L (for DC power 17
source) or CP-23L Charge indicator
(for 12 V cigarette Lights orange : While charging 18
lighter socket) can Lights green : Charging is completed.
be used instead of 19
the AC adapter.
12
3 BATTERY CHARGING

Battery case (BP-263) Battery information


When using the battery case (BP-263), install 6 AA (LR6) D Battery life
size alkaline batteries, as described below. Battery pack/case Voltage Capacity Battery life*1
q Remove the battery case if it is attached. (p. 2) Battery case for
w Install 6 AA (LR6) size alkaline batteries. BP-263 *2
AA (LR6) 6 alkaline
Install only alkaline batteries.
Be sure to observe the correct polarity. BP-264 7.2 V 1400 mAh 13 hrs.
e Attach the battery case. (p. 2) BP-265 7.4 V
1900 mAh (min.)
19 hrs.
2000 mAh (typ.)
Be careful! The negative termi-
nals of the battery case protrude *1 When the power save function is set to PS.At, and the operating
from the body, so pay attention time is calculated under the following conditions;
not to injure your fingers when TX : RX : standby = 5 : 5 : 90
inserting the batteries. *2 The average operating life depends on the alkaline cells used.
E
 ven when the transceiver power is OFF, a small current
 CAUTION: still flows in the transceiver. Remove the battery pack/case
W hen installing batteries, make sure they are all the when it wont be used for a long time. Otherwise, the battery
same brand, type and capacity. Also, do not mix new pack or the batteries in the case will become exhausted.
and old batteries together.
Keep battery terminals clean. Its a good idea to clean D Battery indication
battery terminals once a week. The battery indicator, , appears when a battery pack/
Never incinerate used battery cells since the internal case is attached to the transceiver.
battery gas may cause them to rupture.
Never expose a detached battery case to water. If the bat- Indicator Battery condition
tery case gets wet, be sure to wipe it dry before using it.
The battery has ample capacity.
Never use batteries whose insulated covering is damaged.
 he battery is nearing exhaustion.
T
 NOTE: When the battery case is attached, the battery pro- Charging the battery pack, or replacing the batteries
tection function must be turned OFF in the Initial Set mode in the case is necessary.
13 (p. 47).
BASIC OPERATION 4
Power ON Adjusting the squelch level 1
Push and hold [ ] for 1 sec. to turn the power ON. While pushing and holding [MONI], push [] or [] sev-
2
Push and hold [ ] for 1 sec. to turn the power OFF. eral times to adjust the squelch level. 3
SqL 1 is loose squelch (for weak signals) and SqL10 is tight
squelch (for strong signals). SqL 0 is open squelch. 4
5
6
7
8
9
10
11
Adjusting the volume level 12
Rotate [VOL] to adjust the volume level. Monitor function 13
If the squelch is closed, push and hold [MONI] while adjusting the
This function is used to listen to weak signals or to open 14
volume level.
The display shows the volume level while adjusting. the squelch manually. You can use it without disturbing the 15
squelch setting, even when mute functions such as the tone
squelch are in use. 16
Push and hold [MONI] to monitor the operating frequency. 17
blinks while the monitor function is ON.
18
19
14
4 BASIC OPERATION

Mode selection
P ush [VFO/MR/CALL] several D Memory mode
times to select the VFO mode, The memory mode is used for Memory mode display
memory mode, Call channel mode operating on memory channels,
and weather channel mode*, in se- which store programmed fre-
quence. quencies.
*For only the U.S.A. version transceivers.  appears when the memory Appears
mode is selected.

D Call channel mode


The Call channel is used for Call channel mode display
D VFO mode quick recall of the most often-
The VFO mode is used to set VFO mode display used frequency.
the operating frequency.  C appears instead of the memory
channel number when the Call Appears
channel mode is selected.

What is VFO? D Weather channel mode*


VFO is an abbreviation of Variable Frequency Oscillator. Fre- There are 10 weather channels Weather channel mode
quencies for both transmitting and receiving are generated for monitoring weather broad- display
and controlled by the VFO. casts from NOAA (National
Oceanic and Atmospheric Ad-
ministration).
*O nly for the U.S.A. version trans-
ceivers.

15
BASIC OPERATION 4

Operating mode selection Setting a frequency 1


D Using [] or [] 2
Operating modes are determined by the modulation of the
radio signals. The transceiver has the FM and FM-N modes. q Push [VFO/MR/CALL] several times to select the VFO 3
The mode selection is independently stored for each memory mode.
channel.
4
w Push [] or [] to select the desired frequency.
q Push [FUNC](M) then [SET](8) to enter the Set mode. The frequency changes according to the preset tuning steps. 5
w Push [] or [] to select the operating mode item. (W/n) See the previous topic to set the tuning step.
6
e Rotate [VOL] to set the operating mode to FM or FM-N.
FM mode FM-N mode
D Using the keypad 7
q Push [VFO/MR/CALL] several times to select the VFO
mode.
8
w To enter the desired frequency, enter 6 digits, starting 9
from 100 MHz digit.
r Push [# ENT] to exit the Set mode.
Entering two or three* to five digits, and then pushing [# ENT], 10
also sets the frequency. (*Depending on the version) 11
Setting a tuning step If a frequency outside the frequency range is entered, the previ-
ously displayed frequency is automatically recalled. 12
The transceiver has 8 tuning step options; Example 1 entering 145.525 MHz 13
5kHz 10kHz 12.5kHz 15kHz 20kHz
25kHz 30kHz 50kHz
Push 14
The tuning step can be selected in the Set mode.
15
q Push [FUNC](M), and then [SET](8) to enter the Set mode. 16
w Push [] or [] to select the tuning step item. (tS) Example 2 entering 144.800 MHz
e R otate [VOL] to select the 20 kHz tuning step
17
Push
desired tuning step. 18
r Push [# ENT] to exit the Set
mode. 19
16
4 BASIC OPERATION

Receiving Transmitting
Make sure the BP-264 or BP-265 battery pack is fully  AUTION: Transmitting without an antenna will damage
C
charged, or the BP-263 battery case has brand new alkaline the transceiver.
batteries (pp.1113).  OTE: To prevent interference, push and hold [MONI] to
N
listen on the frequency before transmitting.
q Push and hold [ ] for 1 sec. to turn power ON.
w Rotate [VOL] to set the desired volume level. (p. 14) q Set the operating frequency. (p. 16)
The volume level is displayed on the LCD while adjusting.
w Push [FUNC](M), and then push [H/M/L](9) to select the
e Set the receive frequency. (p. 16) output power between High (5.5 W), Mid (2.5 W) and Low
r Set the squelch level. (p. 14) (0.5 W).
While pushing and holding [MONI], push [] or [].
 H, M, or L appears according to the selected output power.
The squelch level is displayed on the LCD while setting.
e Push and hold [PTT] to transmit.
SqL 1 is loose squelch (for weak signals) and SqL10 is tight
 appears while transmitting.
squelch (for strong signals). SqL 0 is open squelch.
The signal indicator shows the output power level.
Push and hold [MONI] to open the squelch manually.
r Speak into the microphone using your normal voice level.
t When a signal is received: DO NOT hold the transceiver too close to your mouth or speak
The squelch is opened and the audio is heard.
too loudly. This may distort your speech.
The signal indicator shows the relative signal strength level.
t Release [PTT] to return to receive.

w Adjust the volume level.

e Push and hold to


transmit.
r For the squelch level setting. t Release to receive.
(Push to monitor)
Microphone
q Turn the power ON.
Push to monitor.
e Set the frequency.
r Adjust the squelch level. w Select the q Set the frequency.
output power.
17
BASIC OPERATION 4

R WARNING! When using the BP-263 battery case, fre- [VOL] function assignment 1
quent or continuous transmissions can cause the batter-
ies to overheat, and may cause a burn. To prevent this, the [VOL] can be used as a tuning control instead of [] and
2
default time-out timer is set to 5 minutes (p. 44). Be careful [], to suit your preference. However, when [VOL] functions 3
when the time-out timer function is turned OFF or set to a as a tuning control, [] and [] function as volume controls.
long time period, and transmission is made for long periods.
4
q While pushing and holding [] and [], turn the power
We recommend using the middle or low power setting. 5
ON to enter the Initial Set mode.
w Push [] or [] to select the dial assignment item. (tOP) 6
e Rotate [VOL] to select an option.
Key lock function r Push [# ENT] to exit the Initial Set mode.
7
8
To prevent accidental frequency changes, or unnecessary
function access, use the key lock function.
[VOL] 9
Push [FUNC](M), and then push and hold [ ](# ENT) for
10
1sec. to turn the key lock function ON or OFF.
[VOL] functions as the volume control.
appears while the key lock function is activated. 11
[ ], [VOL], [MONI], [PTT] and [FUNC](M) + [ ](# ENT)
are still operable while the key lock function is ON.
12
13
14
[VOL] functions as the tuning control.
15
[ VOL] and []/[] function as described below, depend- 16
ing on the option.
17
Option [VOL] []/[]
Appears
18
tOP.VO Volume control Tuning controls
tOP.di Tuning control Volume controls
19
18
4 BASIC OPERATION

Weather channel operation U.S.A. version only

There are 10 weather channels for monitoring q Select a weather channel.


weather broadcasts from NOAA (National Oce- w Turn the weather alert function ON in the Set mode.
anic and Atmospheric Administration). Push [FUNC](M), and then [SET](8) to enter the Set
mode.
Push [] or [] to select the weather alert item. (ALt)
D Weather channel selection Rotate [VOL] to select ON.
q P ush [VFO/MR/CALL] several times to select the Push [# ENT] to exit the Set mode.
weather channel mode. e Set the desired stand-by mode.
Weather channel mode Select the VFO, memory or Call channel mode.
display Scan or priority watch operation can also be selected.
r When an alert is detected, a beep sounds, and ALt and
the weather channel number will be alternately displayed.

w Push [] or [] to select a weather channel.


e Push [VFO/MR/CALL] to return to the previous frequency
or memory channel.
t Turn the weather alert function OFF in the Set mode.
D Weather alert function
NOAA broadcast stations transmit weather alert tones be-  OTE: While receiving a signal on a frequency other than
N
fore important weather announcements. When the weather the Weather alert frequency, the receiving signal will be
alert function is ON, the selected weather channel is moni- interrupted momentarily approximately every 5 sec. when
tored every 5 sec. for announcements. When the alert signal the weather alert function is ON. These interruptions
is detected, the ALt and the WX channel number are alter- cease when the weather alert function is turned OFF.
nately displayed, and a beep sounds until the transceiver is  ush [FUNC](M), and then [SCAN](5) to start a weather
P
operated. The previously selected (used) weather channel is channel scan. Push any key except []/[], [FUNC](M)
checked periodically during standby, or while scanning. and [MONI] to stop the scan.

19
REPEATER AND DUPLEX OPERATION 5
Repeater operation 1
When using a repeater, the transmit frequency is shifted r Push and hold [PTT] to transmit. 2
from the receive frequency by the frequency offset (p. 21). The displayed frequency automatically changes to the transmit 3
This is called duplex operation. It is convenient to program frequency (repeater input frequency).
repeater information into memory channels (p. 25). If OFF appears, check the frequency offset and shift direction 4
Repeater
(p. 21). 5
t Release [PTT] to receive.
144.700 MHz 144.700 MHz Uplink
(transmit freq.)
While receiving While transmitting
6
Downlink
145.300 MHz 145.300 MHz
(receive freq.) 7
8
Station A Station B
9
y Push and hold [MONI] to check whether the other stations
transmit signal can be directly received or not. 10
When the other stations signal can be directly received, move
q Set the receive frequency (the repeater output frequency). to a non-repeater frequency to use simplex. (duplex OFF)
11
w Push [FUNC](M), and then [DUP](4) several times to set 12
the shift direction of the transmit frequency. ( or +;  For the U.S.A. version:
See page 21 for details.) Auto repeater function uses standard values of the re- 13
When the auto repeater function is in use (U.S.A. version only), peater tone frequency and frequency offset. 14
this selection and step e are not necessary. (p. 23).
e If desired, push [FUNC](M) and then [TONE](1) several 15
times to activate the subaudible tone encoder. 16
appears. Appears
S elect the desired subaudible 17
tone frequency. (p. 22) 18
19
20
5 REPEATER OPERATION

Duplex operation
D Setting the frequency offset  For the U.S.A. version:
q Push [FUNC](M), and then [SET](8) to enter the Set mode. The auto repeater function has priority over the manual
w Push [] or [] to select the offset item. duplex setting. If the transmit frequency changes after
 blinks, and the current frequency offset appears. setting, the auto repeater function may have changed the
e Rotate [VOL] to select the frequency offset. duplex setting. Turn the auto repeater function OFF to
T he offset is selected in the 0.6 MHz offset
prevent this (p. 23).
same step as the frequency
tuning step. D Reverse duplex function
T he unit of the frequency When the reverse duplex function is ON, the receive and
offset is MHz. transmit frequencies are reversed. The function can be set in
r Push [# ENT] to exit the Set mode. the Set mode.

D Setting the duplex direction q Push [FUNC](M), and then [SET](8) to enter the Set mode.
w Push [] or [] to select the reverse duplex function item
 ush [FUNC](M), and then [DUP](4) to select (nega-
P (REV).
tive offset) or + (positive offset). e Rotate [VOL] to turn the function ON or OFF.
 or + indicates the transmit frequency is shifter up (+) or r Push [# ENT] to exit the Set mode.
down () from the receive frequency.
Blinking or + indicates the reverse duplex function is ON, Each receive and transmit frequency is shown in the table
as described to the right. below, with the following configurations;
Example When the offset frequency is 0.6 MHz Input freq. : 145.300 MHz Reversed RX freq. TX freq.
Direction : (down)
Duplex While receiving While transmitting Offset : 0.6 MHz OFF 145.300 MHz 144.700 MHz
ON 144.700 MHz 145.300 MHz
+ (up)

 or + blinks when the re-


(down) verse duplex function is ON.

21
REPEATER OPERATION 5

Subaudible tones D Tone information 1


Some repeaters require a different tone system to be ac-
Some repeaters require subaudible tones to be accessed. cessed.
2
Subaudible tones are superimposed over your normal sig- 3
nal, and must be set in advance. DTMF TONES
While pushing [PTT], push the desired DTMF keys, [0] to 4
q Push [FUNC](M) then [SET](8) to enter the Set mode. [9], [MONI](A), [](B), [](C), [VFO/MR/CALL](D), [M](E), 5
w Push [] or [] to select the repeater tone item. (rt) and [# ENT](F), to transmit their assigned DTMF codes.
e Rotate [VOL] to select the desired subaudible tone. The transceiver has 16 DTMF memory channels (p. 35). 6
[VOL] 1750 Hz TONE 7
To access some European repeaters, the transceiver must 8
88.5 Hz repeater tone transmit a 1750 Hz tone burst.
9
For IC-V80E only
Push [PTT] briefly, push and hold [PTT] again for 1 or 2 sec. 10
For other transceivers 11
While pushing [PTT], push and hold either the [] or [] for
1 or 2 sec. See page 36 for details.
12
13
r Push [# ENT] to exit the Set mode.
CONVENIENT! 14
Tone scan function:
Available subaudible tone frequencies (unit: Hz)
If you dont know the subaudible tone used for a repeater,
15
67.0 79.7 94.8 110.9 131.8 156.7 171.3 186.2 203.5 229.1
69.3 82.5 97.4 114.8 136.5 159.8 173.8 189.9 206.5 233.6
the tone scan is convenient for detecting the tone frequency. 16
71.9 85.4 100.0 118.8 141.3 162.2 177.3 192.8 210.7 241.8
74.4 88.5 103.5 123.0 146.2 165.5 179.9 196.6 218.1 250.3
Push [FUNC](M), and then [T.SCAN](3) to start a tone 17
scan.
77.0 91.5 107.2 127.3 151.4 167.9 183.5 199.5 225.7 254.1
When the required tone frequency is detected, the scan pauses,
18
and the tone frequency is temporarily set. 19
See page 34 for details of the tone scan function.
22
5 REPEATER OPERATION

Lockout function Auto repeater function


U.S.A. version only
The lockout function helps prevent interference to other sta-
tions by inhibiting transmitting when the channel is busy. The auto repeater function sets the standard repeater set-
The function can be set in the Initial Set mode. tings (duplex ON/OFF, duplex direction, tone encoder ON/OFF)
when the operating frequency falls within or outside of the
q While pushing and holding [] and [], turn the power
general repeater output frequency range. The offset and
ON to enter the Initial Set mode.
repeater tone frequencies are not changed by the auto re-
w Push [] or [] to select the lockout item. (RLO)
peater function. Reset these frequencies, if necessary.
e R otate [VOL] to select the lockout function option be-
The function can be set in the Initial Set mode.
tween OFF, repeater lockout, and busy lockout.
RLO.OF : Allows transmitting, even if signals are received. q While pushing and holding [] and [], turn the power
RLO.RP : T
 he repeater lockout function inhibits transmitting ON to enter the Initial Set mode.
when the channel is busy, except while receiving a w Push [] or [] to select the auto repeater item. (RPt)
signal that includes a matched subaudible tone. e Rotate [VOL] to select a desired option.
RLO.bU : The busy lockout function inhibits transmitting while
Rpt.OF : Turns the function OFF.
receiving a signal.
Rpt.R1 : T he auto repeater function is activated for duplex only.
r Push [# ENT] to exit the Initial Set mode. Rpt.R2 : The auto repeater function is activated for duplex and
tone encoder.
[VOL] r Push [# ENT] to exit the Initial Set mode.
The repeater lockout function Frequency range and offset direction
is ON.
Frequency range Duplex direction
145.200 to 145.495 MHz
appears.
146.610 to 146.995 MHz
147.000 to 147.395 MHz + appears.

23
MEMORY/CALL OPERATION 6
General description D Using the keypad 1
q Push [VFO/MR/CALL] several times to select the memory
The transceiver has 207 memory channels, including 6 scan mode.
2
edge memory channels (3 pairs), and 1 Call channel, for  X appears. 3
storage of often-used frequencies. w To select a desired channel, enter the 3 digits of the chan-
nel number using the keypad.
4
D Memory channel contents Blank channels are also selectable. 5
The following information can be programmed into a mem- Entering one or two digits, and then pushing [# ENT] also se-
ory channel: lects a memory channel. 6
Operating frequency (p.16) Example selecting memory channel 14 7
Operating mode (p.16) Push
Duplex direction (+ or ) with frequency offset (p.21) 8
Reverse duplex function ON/OFF (p.40)
S ubaudible tone encoder (p.20), tone squelch or DTCS 9
squelch ON/OFF (p.33) 10
Subaudible tone frequency (p. 22), tone squelch frequency or
Appears The memory channel
DTCS code with polarity (pp.32, 33) is selected. 11
Skip setting (p.30)
Tuning step (p.16) 12
Output power (p.17)
TX permission (p.41)
Selecting the Call channel 13
Push [VFO/MR/CALL] several times to select the Call 14
Selecting a memory channel channel.
 C appears instead of the memory channel number.
15
D Using [] or [] 16
q Push [VFO/MR/CALL] several times to select the memory Push 17
mode. 18
 X appears. Appears
w Push [] or [] to select a desired channel. 19
O
 nly programmed channels are displayed.
24
6 MEMORY/CALL OPERATION

Channel programming
q Push [VFO/MR/CALL] several times to select the VFO t P ush [FUNC](M), and then push and hold [VFO/MR/
mode. CALL] for 1sec. to store the entry.
w Set a desired frequency. (p. 16) 3 beeps sound.
If desired, set other data (e.g. offset frequency, duplex If you continue to push and hold [VFO/MR/CALL] for 1 sec.
direction, tone squelch, etc.). after programming, the memory channel number automatically
e Push [FUNC](M), and then [VFO/MR/CALL]. increases.
X and the memory channel number blink.
NOTE: To cancel programming, push [VFO/MR/CALL]
Select the Call channel mode to program the Call channel.
r Push [] or [] to select a desired channel. before storing the entry in step t.
Select 1A/1B to 3A/3B to program a scan edge channel.

Example programming 145.440 MHz into memory channel 11 (a blank channel).


Push , and then . Push or to select channel 11.

The VFO mode

Push , then push and hold for 1 sec. to program.

Return to the VFO mode.

25
MEMORY/CALL OPERATION 6

Copying memory/Call contents 1


This function transfers a memory channels contents to D Memory/Callmemory/Call 2
VFO (or another memory/Call channel). This is useful when 3
q Select a memory or Call channel to be copied.
searching for signals around a memory channel frequency
P ush [VFO/MR/CALL] several times to select the
and for recalling the offset frequency, subaudible tone fre-
memory mode or the Call channel mode, and then
4
quency etc.
push [] or [] to select a desired channel. 5
D Memory/CallVFO w Push [FUNC](M), and then push [VFO/MR/CALL].
6
X and -- blink.
q Select a memory (Call) channel to be copied.
P ush [VFO/MR/CALL] several times to select the
Do not hold [VFO/MR/CALL] for more than 1sec., otherwise 7
the memory contents will be copied to the VFO mode.
memory or Call channel mode, and then push [] or
e Push [] or [] to select the target memory or Call chan-
8
[] to select a desired channel.
w Push [FUNC](M), and then push and hold [VFO/MR/
nel. 9
r Push [FUNC](M), and then push and hold [VFO/MR/
CALL] for 1 sec. to transfer the selected memory contents
CALL] for 1 sec. to copy. 10
to the VFO mode.
The VFO mode is automatically selected. 11
12
Example copying memory channel 11 to the VFO mode. 13
Push , then push and hold for 1 sec. 14
15
16
Memory mode VFO mode. 17
18
19
26
6 MEMORY/CALL OPERATION

Clearing memory contents Display type


The contents of programmed memories can be cleared During memory mode operation, the transceiver has 3 dis-
(erased). play types to suit your operating style.
Set the display type in the Initial Set mode. (p. 46)
q For only the U.S.A. version, select any mode other than
the weather channel mode. Frequency display
w Push [FUNC](M), and then push [VFO/MR/CALL]. Displays the programmed frequency.
e Push [] or [] to select a channel to be cleared.
r Perform the following operation within 1.5 sec., otherwise
the transceiver returns to the memory mode without clear- Channel number display
ing memory. Displays the memory channel num-
-P ush [FUNC](M), and then momentarily push [VFO/MR/ ber. Only programmed channels are
CALL]. displayed, and modes other than the
- Push [FUNC](M), and then push and hold [VFO/MR/ memory mode cannot be selected.
CALL] for 1 sec. When the channel number display type is selected, only the follow-
The channel contents are cleared. ing functions can be performed.
t Push [VFO/MR/CALL] to return to the previous mode. - Scan function (p. 30) - Out put power setting (p. 17)
- DTMF memory function (p. 35) - Key lock function (p. 18)
NOTE: Be careful! the contents of cleared memories - The scan pause timer setting, the function key timer setting, the
CANNOT be recalled. LCD backlight setting, the VOX-related settings, the microphone
gain setting, and the DTMF TX key setting in the Set mode.

Channel name display


Displays the channel name you have
assigned. Only programmed chan-
nels are displayed.
If no channel name is programmed, the programmed frequency
will be displayed.
Push [MONI] to display the operating frequency.

27
MEMORY/CALL OPERATION 6

P
 rogramming a channel name 1
Each memory channel can be programmed with an alphanu- i Rotate [VOL] to select a desired character.
2
meric name for easy recognition and can be displayed inde- The selected character blinks. 3
pendently by channel. Up to 5 characters can be used for a Push [] to move the cursor right, push [] to move the cur-
channel name. sor left.
4
5
q While pushing and holding [] and
[], turn the power ON to enter the [VOL] 6
Initial Set mode.
w Push []/[] to select the channel
o R epeat step i until the desired channel name is pro- 7
grammed.
name display item. (dSP)
!0 Push [# ENT] to exit the programming mode. 8
e Rotate [VOL] to select the channel
name display type, dSP.nm. 9
r Push [# ENT] to exit the Initial Set 10
mode.
t Push [VFO/MR/CALL] several times 11
to select the memory mode. D Usable characters 12
Select the Call channel to program a
Call channel name. 13
(A) (b) (C) (d) (E) (F) (G) (H) (I) (J) (k) (L) (m)
y Push [] or [] to select a desired channel. 14
u Push [FUNC](M), and then [SET](8) to enter the channel
name programming mode. (n) (O) (P) (q) (R) (S) (t) (U) (V) (W) (X) (y) (Z) 15
A cursor blinks for the first character.
(1) (2) (3) (4) (5) (6) (7) (8) (9) (0) 16
17
(+) (-) (=) () (/) (() ()) (:) (Space)
18
19
28
7 SCAN OPERATION

Scan types Programmed scan


A scan automatically searches for signals, and makes it A programmed scan repeatedly scans between two user
easier to locate new stations for contact or listening purposes. programmed frequencies (memory channels 1A3A and
1b3b), or scans between upper and lower band edges.
PROGRAMMED SCAN (See the next topic) This scan is useful for checking for signals within a specific
1A 1b frequency range, such as repeater output frequencies, etc.
Band 2A Scan edges 2b Band
edge 3A 3b edge
q Push [VFO/MR/CALL] several times to select the VFO
Scan mode.
Jump w P ush [FUNC](M), and then
[SCAN](5) to start a scan.
The Programmed scan P1 scans between 1A and 1b, P2
scans between 2A and 2b, and P3 scans between 3A and 3b
frequencies. e P ush [FUNC](M), and then
[SET](8) several times to se-
MEMORY (SKIP) SCAN (p.30) lect a desired scan type be-
Mch 1 Mch 2 Mch 3 Mch 4 Mch 5 tween P1, P2, P3 or AL.
AL for full scan, P1, P2 and P3 for programmed scan be-
Mch 0 SKIP SKIP Mch 6
tween the programmed scan edge channels 1A1b, 2A
Mch 199 Mch 10 Mch 9 Mch 8 Mch 7 2b and 3A3b.
To change the scan direction, push [] or [].
r To cancel the scan, push any key except [ ], []/[],
PRIORITY WATCH (p.31)
[MONI] or [FUNC](M).
Memory/Call channel watch Memory scan watch
5 sec. 5 sec.
Mch 0 NOTE: Scan edge channels, 1A3A/1b3b, must be pro-
Memory SKIP Mch 1 grammed in advance. Program them in the same manner
VFO VFO
frequency
(Call) frequency Mch 2 as regular memory channels. (p. 25)
channel If identical frequencies are programmed into the scan
Mch 199
edge channels, the programmed scan will not function.
29
SCAN OPERATION 7

Memory Scan Scan resume setting 1


A memory scan repeatedly scans memory channels, except When a signal is received during a scan, the scan resume
2
those set as skip channels. setting determines what action the transceiver takes. The 3
transceiver has 2 scan resume settings, as described below.
q Push [VFO/MR/CALL] several times to select the mem-
Use the Set mode to select the one which best suits your 4
ory mode.
X appears.
needs. 5
w P u s h [ F U N C ] ( M ) , t h e n q Push [FUNC](M), and then [SET](8) to enter the Set mode. 6
[SCAN](5) to start the scan. w Push [] or [] to select the scan pause timer item (SCt,
To change the scan direction, or SCP). 7
push [] or []. e Rotate [VOL] to select a desired scan pause option. 8
e To cancel the scan, push any key except [ ], []/[], Pause scan
[MONI] or [FUNC](M). The scan pauses until the received signal disappears, 9
and then resumes after 2 sec. 10
Timer scan
Setting skip channels The scan pauses for 5 sec., 10 sec. or 15 sec., and then 11
In order to speed up the scan rate, you can set the memory
resumes. 12
r Push [# ENT] to exit the Set mode.
channels you dont want to scan as skip channels. 13
q Select a memory channel to be skipped. [VOL] Pause scan
14
P ush [VFO/MR/CALL] several times to select the
memory mode, and then push [] or [] to select a 15
desired channel. 16
w P ush [FUNC](M), and then
[SKIP](6) to turn the skip Timer scan (15 sec.) 17
setting ON or OFF.
 SKIP appears when the chan-
18
Appears
nel is set as a skip channel. 19
30
7 SCAN OPERATION

Priority watch
A priority watch checks for signals on priority channels D Memory scan watch
while operating on a VFO frequency. While operating on a VFO frequency, a memory scan watch
checks for signals on each memory channel in sequence,
D Memory or Call channel watch every 5 sec.
While operating on a VFO frequency, the memory or Call
channel watch checks for signals on the selected channel q Push [VFO/MR/CALL] several times to select the memory
every 5 sec. mode.
w Push [FUNC](M), and then [SCAN](5) to start a memory
q Select a desired memory channel or the Call channel. scan.
w Push [FUNC](M), and then [PRIO](7) to start the watch. e Push [FUNC](M), and then [PRIO](7) to start the watch.
The decimal point ., on the frequency readout blinks. The VFO mode is selected, and the decimal point ., on the fre-
When a signal is detected on the channel, the watch resumes quency readout blinks.
according to the scan resume setting. (p. 30) When a signal is detected on a channel, the watch resumes ac-
VFO frequency Memory channel cording to the scan resume setting. (p. 30)
Memory scan
VFO frequency
Mch 0
5 sec. Mch 1 SKIP
Mch 2
e To cancel the watch, push any key except [ ], []/[], Mch 199
[MONI], [FUNC](M), or [PTT]. 5 sec.

r To cancel the watch, push any key except [ ], []/[],


[MONI], [FUNC](M), or [PTT].

31
TONE SQUELCH AND POCKET BEEP 8
Tone/DTCS squelch and pocket beep 1
D Tone squelch and DTCS squelch D Setting CTCSS tone or DTCS code 2
The tone squelch (CTCSS) or DTCS squelch opens only q Push [FUNC](M), and then [SET](8) to enter the Set mode. 3
when receiving a signal that includes a matched CTCSS tone w Push [] or [] to select the CTCSS tone item (Ct) or 4
or DTCS code, respectively. You can silently wait for calls the DTCS code item (dt).
using the same tone or code. Separate tone frequencies can  blinks when selecting the CTCSS tone item, and D blinks 5
be set for repeater and tone squelch/pocket beep operation. when selecting the DTCS code item.
6
e Rotate [VOL] to select a desired CTCSS tone or DTCS
D Pocket beep code. 7
The pocket beep function uses subaudible tones or DTCS The recommended CTCSS tone or DTCS code are shown to
codes for calling, and can be used as a common pager to the left.
8
inform you that someone has called while you were away r Push [# ENT] to exit the Set mode. 9
from the transceiver.
10
Recommended CTCSS tones (unit: Hz) [VOL] CTCSS tone setting
11
67.0 79.7 94.8 110.9 131.8 156.7 186.2 225.7
69.3 82.5 97.4 114.8 136.5 162.2 192.8 233.6 12
71.9 85.4 100.0 118.8 141.3 167.9 203.5 241.8 13
74.4 88.5 103.5 123.0 146.2 173.8 210.7 250.3
77.0 91.5 107.2 127.3 151.4 179.9 218.1
DTCS code setting
14
Recommended DTCS code
15
023 051 114 143 174 251 315 371 445 532 631 723 16
025 054 115 152 205 261 331 411 464 546 632 731
17
026 065 116 155 223 263 343 412 465 565 654 732
031 071 125 156 226 265 346 413 466 606 662 734 18
032 072 131 162 243 271 351 423 503 612 664 743
043 073 132 165 244 306 364 431 506 624 703 754 19
047 074 134 172 245 311 365 432 516 627 712
32
8 TONE SQUELCH AND POCKET BEEP

D Setting DTCS polarity D Operation


For DTCS operation, the polarity setting is also configurable, q Set a desired operating frequency, and then a CTCSS tone
as well as the code setting. If the polarity is different, the or a DTCS code.
DTCS squelch never opens, even when receiving a signal w Push [FUNC](M), and then [TONE](1).
that includes a matched DTCS code. Repeat step w several times to activate a desired tone function.

q Push [FUNC](M), and then [SET](8) to enter the Set mode. Push , and then to select the tone function in sequence.
w Push [] or [] to select the DTCS polarity item (dtP).
e Rotate [VOL] to select a desired polarity setting between
dtP.nn (normal), dtP.nR (TX: normal, RX: reverse), dtP.Rn
(TX: reverse, RX: normal) and dtP.RR (reverse). Repeater tone Function OFF

TX/RX: Normal polarity TX: Normal, RX: Reverse


Tone squelch with DTCS squelch
pocket beep

TX: Reverse, RX: Normal TX/RX: Reverse polarity


Tone squelch DTCS squelch with
pocket beep
r Push [# ENT] to exit the Set mode.
e Operate the transceiver in a normal way.

33
TONE SQUELCH AND POCKET BEEP 8

r W hen receiving a signal that includes a matched tone


Tone scan 1
or code, the squelch opens and the signal can be heard. By monitoring a signal from a repeater, pocket beep or
2
When the pocket beep function is activated. squelch function operation, you can determine the subaudi- 3
Beep tones sound and blinks. To stop the beeps and blink- ble tone required to access the repeater or open the squelch.
ing, push any key. 4
q Set a frequency to be checked for a tone frequency or
W hen the received signals tone/code does not match, the 5
squelch does not open. However, the signal indicator shows the DTCS code.
signal strength. w Push [FUNC](M), and then [TONE](1). 6
Repeat step w several times to activate a desired tone function.
To open the squelch manually, push and hold [MONI].
The tone scan can be made even if the tone function is not se-
7
t Push [PTT] to answer.
lected. 8
e Push [FUNC](M), and then [T.SCAN](3) to start a tone
scan. 9
To change the scan direction, push [] or []. 10
r When a tone frequency or DTCS code is matched, the
squelch opens and the tone frequency or code is tempo- 11
rarily programmed into the selected mode. 12
When a tone frequency or DTCS code is detected, the tone
scan pauses according to the scan resume setting (p.30) 13
The decoded CTCSS tone frequency or DTCS code is used ac- 14
cording to the selected tone function type in step w.
- No indication : Cannot be used for operation. 15
- : CTCSS tone encoder (repeater tone)
16
- : CTCSS tone encoder/decoder
- D : DTCS tone encoder/decoder 17
t To cancel the scan, push any key except [ ], []/[], 18
[MONI] or [FUNC](M).
19
34
9 DTMF MEMORY

Programming a DTMF code sequence


The DTMF codes are used for autopatching, accessing re- r Push keys to input a desired DTMF code sequence of up
peaters, controlling other equipment, and other operations. to 24 digits.
The transceiver has 16 DTMF memory channels (d0d9, [ 0][9] inputs 09, [MONI] inputs A, [p ] inputs B, [q ]
dA, db, dC, dd, dE, dF) for storage of often-used DTMF code inputs C, [VFO/MR/CALL] inputs D, [M] inputs M (E) and [#
sequence of up to 24 digits. ENT] inputs # (F).
If a digit is mistakenly input, push [PTT] momentarily, then re-
q P ush [FUNC](M), and then [DTMF.M](0) to enter the peat from step e.
DTMF memory mode.

Push , and then .


The next page appears when
the 6th digit has been input.
w Push [p] or [q] to select a desired DTMF memory chan-
t Repeat step r until the desired code is input.
nel.
y Push [PTT] to store the DTMF code sequence and exit
If programmed, the previously programmed DTMF code is dis-
the programming mode.
played.
After the 24th digit is input, the transceiver automatically stores
e Push [FUNC](M), and then push and hold [DTMF.M](0) for
the code sequence and returns to step w.
1 sec. to enter the programming mode.
u Push [VFO/MR/CALL] to exit the DTMF memory.
_ _ _ _ _ appears.
Programmed memories will be cleared by this operation. P
 rogramming mode indication
The programming mode consists of 5 pages.
Push , and then push
Page Digits Indication
and hold for 1 sec.
1st 1st to 5th No indication.
2nd 6th to 10th appears.
3rd 11th to 15th appears.
4th 16th to 20th appears.
5th 21st to 24th blinks.
35
DTMF MEMORY 9

Transmitting a DTMF code sequence 1


2
The transceiver has 3 methods of transmitting a DTMF code D Using a DTMF memory channel
sequence. Select a desired option in the Set mode.
First, set the DTMF TX key to dmt.m in the Set mode. 3
q Push [FUNC](M), and then [SET](8) to enter the Set mode. 4
While pushing and holding [PTT], push one of the keys
w Push [] or [] to select the DTMF TX key item (dmt).
to transmit the programmed DTMF code sequence in the
e Rotate [VOL] to select a desired option. 5
DTMF memory.
dmt.k : Transmits the appropriate DTMF code assigned to the Pushing [0] to [9], [MONI](A), [](B), [](C), [VFO/MR/CALL] 6
pushed key. (D), [M](E), or [# ENT](F) transmits a DTMF code channel (d0
dmt.m : T ransmits the programmed DTMF code sequence in the d9, dA, dB, dC, dD, dE or dF) respectively.
7
DTMF memory channel assigned to the pushed key. 8
dmt.t : N o DTMF code can be transmitted. However, while D 1750 Hz tone
pushing and holding [PTT], pushing either the [] or 9
 o access some European repeaters, the transceiver must
T
[] transmits a 1750 Hz tone burst signal.
transmit a 1750 Hz tone burst signal. 10
r Push [# ENT] to exit the Set mode. This tone can be used as a Call signal in countries out of Europe.
First, set the DTMF TX key to dmt.t in the Set mode.
11
D Manual DTMF code transmission While pushing and holding [PTT], push and hold either 12
First, set the DTMF TX key to dmt.k in the Set mode. the [] or [] for 1 or 2 sec. to transmit a 1750 Hz tone 13
burst signal.
While pushing and holding [PTT], push the desired keys While pushing and holding the key, the tone is transmitted. 14
to transmit a DTMF code sequence manually.
Push [0][9] for 09, [MONI] for A, [] for B, [] for C, 15
[VFO/MR/CALL] for D, [M] for M, and [# ENT] for #.
16
17
18
19
36
9 DTMF MEMORY

Confirming a DTMF memory Setting DTMF transfer speed


A DTMF memory can be confirmed with a DTMF tone. When slow DTMF transmission speeds are required with
DTMF memory transmission (as for some repeaters), the
q P ush [FUNC](M), and then [DTMF.M](0) to enter the transceivers rate of DTMF transmission can be adjusted in
DTMF memory mode. the Initial Set mode.
w Push [p] or [q] to select a desired DTMF memory chan-
nel. q While pushing and holding [] and [], turn the power
e Push [MONI] to confirm the DTMF memory contents. ON to enter the Initial Set mode.
The programmed DTMF code sequence sounds. w Push [] or [] to select the DTMF speed item. (dtd)
After sounding, the transceiver exits the DTMF memory mode. e Rotate [VOL] to select a desired speed.
dtd. 1 : 100 msec. interval; 5.0 cps rate
dtd. 2 : 200 msec. interval; 2.5 cps rate
The programmed DTMF code dtd. 3 : 300 msec. interval; 1.6 cps rate
sequence sounds.
dtd. 5 : 500 msec. interval; 1.0 cps rate
(cps=characters per second)
r Push [# ENT] to exit the Initial Set mode.

Exits the DTMF memory mode.

37
SET MODES 10
Set mode programming 1
The Set mode is used to change the settings of the trans- D Set mode operation 2
ceivers functions. q Push [FUNC](M), and then [SET](8) to enter the Set mode. 3
w Push [] or [] to select the desired item.
e Rotate [VOL] to select the option or value.
4
r To exit the Set mode, push [# ENT]. 5
Repeater tone
frequency (p. 39)
Tone squelch
frequency (p. 39) DTCS code (p. 39) DTCS polarity (p. 39) Frequency offset (p. 40)
6
7
8
Operating mode (p. 42) Reverse duplex functon (p. 40)
9
: Push 10
DTMF TX key (p. 42) : Push Tuning step (p. 40) 11
12
*Appears for only the U.S.A.
version transceivers. 13
VOX time-out timer (p. 42) Scan resume setting (p. 40)
14
NOTE: When the display type setting (pp. 27, 46) is set
to CH in the Initial Set mode, and accessing the Set 15
mode from the memory mode, most of Set mode items
VOX delay (p. 41) do not appear. Function key timer (p. 40) 16
17
18
Microphone gain (p. 41) VOX gain (p. 41) Weather alert* (p. 41) TX permission (p. 41) LCD backlight (p. 41)
19
38
10 SET MODES

Set mode items


D Repeater tone frequency D DTCS Code
Selects one of 50 subaudible tone frequencies used to ac- Selects one of 104 DTCS (both encoder/decoder) codes.
cess the repeaters. 023754 (default: 023)
67.0254.1 Hz (default: 88.5 Hz)

Available DTCS codes


D Tone squelch frequency 023
025
054
065
125
131
165
172
245
246
274
306
356
364
445
446
506
516
627
631
732
734
Selects one of tone frequencies for tone squelch or pocket 026 071 132 174 251 311 365 452 523 632 743
beep operation. 031 072 134 205 252 315 371 454 526 654 754
032 073 143 212 255 325 411 455 532 662
67.0254.1 Hz (default: 88.5 Hz) 036 074 145 223 261 331 412 462 546 664
043 114 152 225 263 332 413 464 565 703
047 115 155 226 265 343 423 465 606 712
051 116 156 243 266 346 431 466 612 723
053 122 162 244 271 351 432 503 624 731

Usable subaudible tone frequencies (unit: Hz)


D DTCS Polarity
67.0 79.7 94.8 110.9 131.8 156.7 171.3 186.2 203.5 229.1 Selects the DTCS polarity between dtP.nn (normal), dtP.nR
69.3 82.5 97.4 114.8 136.5 159.8 173.8 189.9 206.5 233.6
71.9 85.4 100.0 118.8 141.3 162.2 177.3 192.8 210.7 241.8
(TX: normal, RX: reverse), dtP.Rn (TX: reverse, RX: normal) and
74.4 88.5 103.5 123.0 146.2 165.5 179.9 196.6 218.1 250.3 dtP.RR (reverse). (default: dtP.nn)
77.0 91.5 107.2 127.3 151.4 167.9 183.5 199.5 225.7 254.1 The DTCS codes polarity for transmitting or receiving can
be independently set by this item.
The transceiver has 50 tone frequencies and conse-
quently their spacing is narrow compared with units hav-
ing 38 tones. Therefore, some tone frequencies may re-
ceive interference from adjacent tone frequencies. TX/RX: Normal polarity TX/RX: Reverse polarity
39
SET MODES 10

D Frequency offset D Scan resume setting 1


Selects the frequency offset between 0 and 20 MHz, for re- Selects the scan resume setting between SCt. 5, SCt. 10, 2
peater operation. SCt.15, and SCP. 2.
The frequency offset means the difference between the When a signal is received during a scan, the scan pauses 3
transmit and receive frequencies. and then resumes, according to the scan resume setting.
(default: differs depending on the version)
4
SCt. 5/10/15 : The scan pauses for 5, 10 or 15 sec., and then re-
sumes. (default: SCt.15) 5
SCP.2 : T he scan pauses until the received signal disap-
pears, and then resumes after 2 sec. 6
7
D Reverse duplex function 8
Turns the reverse duplex function ON or OFF. (default: OFF)
9
D Function key timer
Push [FUNC](M) to enter the Function mode, and then push
10
a keypad key to activate its second function. 11
During the Function mode, is displayed on the LCD.
D Tuning step Set the time between when Function mode is entered, and 12
Selects the tuning step from 5, 10, 12.5, 15, 20, 25, 30 and how long it remains activated after you push the keypad key 13
50 kHz. (default: differs depending on the version) to activate its second function.
F0.At : E xits the Function mode immediately after a key is
14
pushed to activate its second function. (default) 15
F1/2/3.At : The Function mode remains activated for the selected pe-
riod after a key is pushed to activate its second function. 16
F .m : The Function mode remains activated until [FUNC](M)
is pushed again, even after a key is pushed to activate 17
its second function. 18
19
40
10 SET MODES

D LCD backlight D VOX gain


Selects the LCD backlight function. Sets the VOX gain to between 1 and 10. Higher values make
LIG.OF : Turns the backlight function OFF. the VOX function more sensitive to your voice.
LIG.ON :L  ights continuously while the transceiver is ON. To turn the VOX function OFF, select VOX.OF.
LIG.At : Turns ON when an operation occurs, and turns OFF (default: VOX.05)
after 5 sec. (default)

NOTE: Set the microphone gain before setting the VOX


gain. See page 52 for details of the VOX function.
D TX permission
Selects whether or not to allow transmitting.
tX .OF : Inhibits transmitting. (Receive only) D Microphone gain
tX .ON : Allows transmitting. (default)
Sets the microphone gain to between 1 and 4 to suit your
preference. Higher values make the microphone more sensi-
tive to your voice. (default: mic.2)

D Weather alert U.S.A. version only


Turns the Weather Alert function ON or OFF. (p. 19)
(default: OFF) NOTE: When using the VOX function, we recommend
setting the microphone gain to 3. However, you can adjust
it to suit your operating environment (including your head-
set performance).

41
SET MODES 10

D VOX delay D DTMF TX key 1


Sets the VOX Delay to between VXd.05 (0.5 sec.), VXd.10 Selects the method to transmit a DTMF code sequence. 2
(1 sec.), VXd.15 (1.5 sec.), VXd.20 (2 sec.), VXd.25 (2.5 While pushing and holding [PTT], push one of the keys,
sec.) and VXd.30 (3 sec.). [0] to [9], [MONI](A), [](B), [](C), [VFO/MR/CALL](D), 3
The VOX Delay is the amount of time the transmitter stays [M](E),and [# ENT](F).
ON after you stop speaking. (default: VXd.10)
4
dmt.k : Transmits the appropriate DTMF code assigned to the
key. (default) 5
dmt.m :T  ransmits the programmed DTMF code sequence in
the DTMF memory channel assigned to the key. 6
dmt.t : N o DTMF code can be transmitted. However, while 7
pushing and holding [PTT], push either the [] or []
D VOX time-out timer to transmit a 1750 Hz tone burst signal. 8
Sets the VOX time-out timer to between 1, 2, 3, 4, 5, 10 and 9
15 min. to prevent accidental prolonged transmission for the
VOX function. 10
To turn the function OFF, select Vto.OF. (default: Vto.03)
D Operating mode 11
Set the operating mode to FM or FM-N. The operating mode 12
is determined by the modulation of the radio signals. 13
(default: W/n. W)
The VOX time-out timer must be set shorter than the time- 14
out timer, otherwise this timer will not be activated. 15
FM mode FM-N mode
16
17
18
19
42
10 SET MODES

Initial Set mode programming


The Initial Set mode can be accessed at power ON and al- D Initial Set mode operation
lows you to set seldom-changed settings, to suit your prefer- q While pushing and holding [] and [], turn the power
ence and operating style. ON to enter the Initial Set mode.
w Push [] or [] to select the desired item.
e Rotate [VOL] to select the option or value.
r To exit the Initial Set mode, push [# ENT].

Key-touch beep (p. 44) Time-out timer (p. 44) Auto repeater* (p. 44) Auto power-OFF (p. 44) Lockout (p. 45)

Squelch delay (p. 45)


Auto low power (p. 47)
: Push

: Push DTMF speed (p. 45)

Battery protection *Appears for only the U.S.A.


function (p. 47) version transceivers.

Dial assignment (p. 45)

Microphone simple
mode (p. 47) Select speed (p. 46) Power save (p. 46) LCD contrast (p. 46) Display type (p. 46)

43
SET MODES 10

Initial Set mode items 1


D Key-touch beep
2
D Auto repeater U.S.A. version only
Turns the key-touch beep ON (the beep level 1 to 3) or OFF. The Auto Repeater function automatically turns ON or OFF 3
When changing the beep level, beeps sound at the level. the duplex operation and the tone encoder. The offset and 4
(default: bEP. 2) the repeater tone are not changed by the function. Reset
these settings, if necessary. 5
RPt.OF : Turns the function OFF. 6
RPt.R1 : Activates for only duplex. (default)
RPt.R2 :A  ctivates for both duplex and tone. 7
D Time-out timer
8
To prevent accidental prolonged transmission, the trans-
ceiver has a time-out timer. This function cuts transmission 9
OFF after 130 min. of continuous transmission. 10
To turn the function OFF, select tot.OF. (default: tot. 5)
D Auto power-OFF
tot.OF : Turns the function OFF. 11
The transceiver can be set to beep and automatically turn
tot. 130 : If continuous transmission exceeds the selected period,
the transmission will be cut off. OFF, when no key operation occurs during a specified period. 12
POF.OF : Turns the function OFF. (default) 13
POF.30/1H/2H : The transceiver is automatically turned OFF when
no operation occurs during the selected period. 14
15
Approx. 10 sec. before the time-out timer is activated, the
transceiver emits a beep tone as a warning. 16
17
Be careful! When using the BP-263 battery case, the NOTE: The setting is maintained even after the trans-
batteries will become hot if this time-out timer function is ceiver is turned OFF by the auto power-OFF function. To 18
turned OFF or set to a long time period, and transmission cancel the function, select POF.OF.
is made for long periods.
19
44
10 SET MODES

D Lockout D DTMF speed


Selects the lockout type between repeater, busy and OFF. Selects a desired DTMF transfer speed.
RLO.OF : Turns the function OFF (default). dtd. 1 : 100 msec. interval; 5.0 cps rate (default)
RLO.RP : T he repeater lockout function inhibits transmitting when dtd. 2 : 200 msec. interval; 2.5 cps rate
the channel is busy, except while receiving a signal that dtd. 3 : 300 msec. interval; 1.6 cps rate
includes a matched tone. dtd. 5 : 500 msec. interval; 1.0 cps rate
RLO.bU : The busy lockout function inhibits transmitting while re- (cps=characters per second)
ceiving a signal.

D Dial assignment
D Squelch delay Selects whether or not to use [VOL] as a tuning control in-
Sets the squelch delay between short and long. The delay stead of [] and []. When [VOL] functions as a tuning con-
prevents the squelch from repeatedly opening and closing trol, [] and [] function as volume controls.
while receiving the same signal. tOP.VO : Audio volume control (default)
Sqd. S : Sets the squelch delay to short (default). tOP.dI : Tuning dial
Sqd. L : Sets the squelch delay to long.

[ VOL] and []/[] function as described below, depend-


ing on the option.

Option [VOL] []/[]


tOP.VO Volume control Tuning controls
tOP.di Tuning control Volume controls

45
SET MODES 10

D Display type D Power save 1


Selects the display type for memory mode operation. The power save function allows you conserve battery life by 2
dSP.FR : Displays the programmed frequency. (default) selecting the duty cycle of the receiver. Select the ratio of the
dSP.CH : D
 isplays the memory channel number. Operable func- power save time to the standby time. 3
tions, configurable items in the Set mode, and select- To turn the function OFF, select PS.OF.
able modes will be restricted.
4
PS.OF : Turns the function OFF.
dSP.nm : D
 isplays the channel name. If no memory name is pro- PS. 2 : Sets the duty cycle to 1:2. 5
grammed, the programmed frequency will be displayed. PS. 8 : Sets the duty cycle to 1:8.
PS.16 : Sets the duty cycle to 1:16.
6
PS.At : Automatically sets the duty cycle. (default) 7
8
D LCD contrast 9
Selects the LCD contrast. 10
Lcd.LO : Sets the contrast to low. D Select speed
Lcd.At : Sets the contrast to high. However, if the transceiver is The tuning speed acceleration automatically speeds up the 11
exposed to high temperatures, it automatically sets the tuning speed when rotating [VOL] rapidly. 12
contrast to low. (default) SS. m : Turns the tuning speed acceleration OFF.
SS. At : Turns the tuning speed acceleration ON. (default) 13
14
15
16
17
18
19
46
10 SET MODES

D Microphone simple mode


Microphone simple mode is used to assign the essential opera-
tions to the four switches (S1 to S4) on the remote control unit.
mS .Sm
S1 Selects the Call channel.
D Battery protection
S2 Turns the monitor function ON or OFF. When the battery voltage decreases, the battery protection
S3 Selects memory channel 0. function automatically turns the transceiver OFF. Select the
S4 Selects memory channel 1. function according to your battery type.
(default: differs depending on the version)
mS .n1 (default)
bAt.OF : Turns the function OFF. Select when you use the
S1 Toggles the VFO mode and the memory mode.
BP-263 battery case.
S2 Selects the Call channel.
bAt.nm : Select when you use the BP-264 Ni-MH battery pack.
S3 Frequency or memory channel UP. bAt.LI : Select when you use the BP-265 Li-Ion battery pack.
S4 Frequency or memory channel DOWN.
mS .n2
S1 Toggles the VFO mode and the memory mode.
S2 Turns the monitor function ON or OFF.
S3 Frequency or memory channel UP.  OTE: BE SURE to select an appropriate option accord-
N
S4 Frequency or memory channel DOWN. ing to your battery type.

U
 ser remote control unit D Auto low power
The below circuit is for reference only.
Turns the auto low power function ON or OFF.
to the [SP] jack
When the temperature goes below 0C (+32F), the function
REMOTE 3.5(d) mm automatically sets the output power to low.
2.7kW 6.8kW 15kW 33kW
In that case, the transmit power selections (Hi/Mid) are also
S1 S2 S3 S4 SP disabled. (default: ALP.OF)
+
GND
EXTERNAL SPEAKER
Rated input >
700 mW (8 W)

47
CLONING 11
Cloning operation 1
Cloning allows you to quickly and easily transfer the e Turn the sub transceiver ON.
2
programmed contents from one transceiver to another. r Push [PTT] on the master transceiver. 3
CL Out appears on the master transceivers display, and the
D Transceiver-to-transceiver cloning signal indicator shows the data is being transferred to the sub 4
transceiver.
q Turn the transceivers power OFF, and then connect an
CL In appears on the sub transceivers display, and the signal
5
optional OPC-474 cloning cable to the [SP] jacks of the
master transceiver and the sub transceiver.
indicator shows the data is being received from the master 6
transceiver.
The master transceiver is used to send data to the sub trans- t When cloning is finished, turn both the transceivers OFF. 7
ceiver. Then turn them ON again to exit the cloning mode. 8
NOTE: DO NOT push [PTT] on the sub transceiver dur-
ing cloning. This will cause a cloning error. 9
10
D Cloning using a PC
The CS-V80 cloning software is also used to clone/edit con- 11
tents with a PC (for Microsoft Windows 2000/XP or Win- 12
dows Vista) using ICF format files.
Master transceiver Refer to the INSTRUCTIONS and the Help file that come 13
with the CS-V80, for details. 14
OPC-478UC
to USB port
15
Sub transceiver (USB type)

w While pushing [FUNC](M) and [], turn the master trans-


16
ceiver ON to enter the cloning mode. 17
CLONE appears
18
OPC-478 to RS-232C
(RS-232C type) port
PC
19
Transceiver
48
12 RESETTING

Resetting
The LCD may occasionally display erroneous infor- D All reset
mation (e.g. when first applying power). This may be The all reset clears all programming and returns all
caused externally by static electricity or by other factors. settings to their factory defaults.
If this problem occurs, turn power OFF. After waiting a q Push and hold [ ] for 1 sec. to turn the power OFF.
few seconds, turn power ON again. If the problem per- w While pushing and holding [MONI] and [VFO/MR/CALL],
sists, perform either or both of the procedures below. push and hold [ ] for 1 sec. to turn the power ON.
CLEAR appears when resetting the CPU.
D Partial reset
If you want to reset the operating conditions (VFO fre-
quency, VFO settings, and Set modes contents) with-
out clearing the memory contents, use the partial reset.
q Push and hold [ ] for 1 sec. to turn the power OFF.
w While pushing and holding [VFO/MR/CALL], push and
hold [ ] for 1 sec. to turn the power ON.

 CAUTION: The all reset returns all programmed contents


to their default settings.

 NOTE: No message appears on the display after the par-


tial reset is done.
49
TROUBLE SHOOTING 13
If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center. 1
PROBLEM POSSIBLE CAUSE SOLUTION REF. 2
The transceiver does not turn The battery is exhausted. Charge the battery pack, or replace the batteries. pp. 1113
ON. The battery polarity is reversed. Check the battery polarity. p. 13
3
Loose connection of a battery pack/case. Clean battery terminals. p. 13 4
No sound comes from the Volume is too low. Rotate [VOL] to adjust to a desired level. p. 14
speaker. An external speaker or a cloning cable is C
 heck the external speaker connection or remove
5
connected to the [SP] jack. the cloning cable. 6
Transmitting is impossible. The battery is exhausted. Charge the battery pack, or replace the batteries. pp. 1113
TX permission is inhibited. Set the TX permission setting to ON in the Set mode. p. 41
7
Transmitting using the VOX The VOX gain is set to OFF or too low. S  et the VOX gain to a suitable level. pp. 41, 53 8
function is impossible. The microphone gain is too low. Set the microphone gain to a suitable level. p. 41
9
Contacting with another sta- A different tone or code is used for the Check the tone/DTCS by performing a tone scan. p. 34
tion is impossible. tone/DTCS squelch. 10
Frequency cannot be set. The key lock function is activated. P ush [FUNC](M), then push and hold [ ] p. 18 11
(# ENT) for 1 sec. to cancel the key lock function.
The memory mode, Call channel mode, or Push [VFO/MR/CALL] several times to select the p. 15 12
weather channel mode is selected. VFO mode.
13
A programmed scan does not The memory mode, Call channel mode, or Push [VFO/MR/CALL] several times to select the p. 15
start. weather channel mode is selected. VFO mode. 14
The same frequency has been programmed P rogram different frequencies in the scan edge p. 25
in the scan edge channels, XAXb. channels.
15
A memor y scan do e s n o t The VFO mode or Call channel mode is Push [VFO/MR/CALL] several times to select the p. 15 16
start. selected. memory mode.
Only one or no memory channel has been Program 2 or more memory channels. p. 25 17
programmed. 18
The displayed frequency is er- The CPU has malfunctioned. Reset the transceiver. p. 49
roneous. External factors have caused a fault. Remove and re-attach the battery pack/case. p. 2 19
50
14 OPTIONS
BP-263 battery case FA-B2E vhf antenna
Battery case for LR6 (AA) 6 alkaline batteries. The same antenna that is supplied with the transceiver.
BP-264 ni-mh battery pack HM-153L earphone-mirophone
7.2 V/1400 mAh (Typ.) Ni-MH battery pack. Battery life: 13 hrs. Ideal for hands-free operation: clip the HM-153L (with inte-
(approx.; FM, high power, Tx : Rx : Standby = 5:5:90) grated PTT switch) to your lapel or breast pocket.
BP-265 li-ion battery pack HM-158L/HM-159L speaker-mirophone
7.4 V/1900 mAh (Min.)/2000 mAh (Typ.) Lithium Ion battery Combination speaker-microphone that provides convenient
pack. Battery life: 19 hrs. (approx.; FM, high power, Tx : Rx : operation while hanging the transceiver on your belt.
Standby = 5:5:90) HS-94/HS-95/HS-97 headset+OPC-2004 plug adapter cable
BC-191 desktop charger+BC-123S ac adapter HS-94 : Ear hook type
For rapid charging of the Ni-MH battery pack. An AC adapter HS-95 : Neck & arm type
may be supplied with the charger, depending on the version. HS-97 : Throat microphone
Charging time: approx. 2 hours for the BP-264. OPC-2004 : Allows you to connect the HS-94/HS-95/HS-97 to
BC-192 desktop charger+BC-147S ac adapter the transceiver. After connecting, the VOX function
For regular charging of the Ni-MH battery pack. An AC adapter can be used.
may be supplied with the charger, depending on the version. SP-27 tube earphone
Charging time: approx. 16 hours for the BP-264. Provides clear audio in noisy environments.
BC-193 desktop charger+BC-123S ac adapter CS-V80cloningsoftware+OPC-478/OPC-478UCcloningcable
For rapid charging of the Li-Ion battery pack. An AC adapter Provides quick and easy programming of such settings as
may be supplied with the charger, depending on the version. memory channels and Set modes contents.
Charging time: approx. 2.5 hours for the BP-265. OPC-474 cloning cable
CP-23L cigarette lighter cable For transceiver-to-transceiver cloning.
Allows charging of the battery packs through a 12 V cigarette
lighter socket. (For only BC-191/BC-193)
OPC-515L dc power cable
Allows charging of the battery packs using a 12 V DC power
source instead of the AC adapter. (For all chargers)
MB-124 belt clip Some options may not be available in some countries. Please
Exclusive alligator-type belt clip. ask your dealer for details.
51
OPTIONS 14

VOX function 1
2
The transceiver has a VOX function, which allows hands-free D Turning the VOX function ON or OFF
operation. q Connect an optional headset and plug adapter cable to 3
An optional HS-94, HS-95 or HS-97 headset and the
OPC-2004 plug adapter cable are also required for operation.
the transceiver, and then turn the power ON. 4
w Push [FUNC](M), and then [VOX](2) to turn the VOX func-
The VOX (voice operated transmission) function starts transmis- tion ON or OFF. 5
sion when you speak into the microphone, without needing to
push [PTT]; then, automatically returns to reception when you stop
 VOX appears when the VOX function is ON. 6
speaking.  NOTE: 7
W hen using the VOX function, adjust the microphone gain
D Optional unit connection and the VOX-related settings (p. 53) to suit your operating 8
q Push and hold [ ] for 1 sec. to turn the power OFF. environment (including your headset performance). 9
w Remove the jack cover. (p. 2) Set the microphone gain before setting the VOX gain in
e C onnect the optional HS-94, HS-95 or HS-97 and the Set mode (p. 41). We recommend setting the micro- 10
OPC-2004, as illustrated below. phone gain to 3. 11
When the TX permission is set to OFF in the Set mode,
OPC-2004 HS-94 you cannot transmit using the VOX function. (p. 41) 12
13
14
w
15
e
16
q 17
Appears
18
[ ]
19
52
14 OPTIONS

D VOX-related settings
The VOX gain, the VOX delay, and the VOX time-out timer can If On is intermittent, be sure the VOX delay is set long
be set in the Set mode. enough to allow normal pauses in speech, but keep the
VOX ON until you finish speaking.
q Connect an optional headset and plug adapter cable to
the transceiver, and then turn the power ON. CONVENIENT!
w Push [FUNC](M), and then [VOX](2) to turn the VOX func- While transmitting using the VOX function, you can adjust
tion ON.
the VOX gain simply by rotating [DIAL].
e Push [FUNC](M), and then [SET](8) to enter the Set mode.
r Push [] or [] to select the VOX gain (VOX), the VOX
VOX delay
delay (VXd), or the VOX time-out timer (Vto) item.
t Rotate [VOL] to select a desired option. Sets the VOX delay to between 0.5 and 3.0 sec. (in 0.5 sec.
y Push [# ENT] to exit the Set mode. steps). The VOX delay is the amount of time the transmitter
stays ON after you stop speaking. (default: VXd.10)
The VOX function does not activate transmission while in
the Set mode.

VOX gain
The VOX delay is set to The VOX delay is set to
The VOX gain level can be adjusted between 1 (minimum) and 1 sec. 3 sec.
10 (maximum), or turned OFF. Higher values make the VOX
function more sensitive to your voice. (default: VOX.05) VOX time-out timer
Sets the VOX time-out timer to between 1, 2, 3, 4, 5, 10 and
15 min. to prevent accidental prolonged transmission for the
VOX function.
The VOX function is The VOX gain is set to To turn the function OFF, select Vto.OF. (default: Vto.03)
turned OFF. 10 (maximum).
While speaking into the head-
set microphone, adjust the
VOX gain until On continu-
ously appears on the LCD. The VOX time-out timer must be set shorter than the time-
Appears
out timer, otherwise this timer will not be activated.
53
SPECIFICATIONS 15
D General 1
Frequency coverage : (unit: MHz) Dimensions : 58(W)112(H)30(D) mm;
Version TX RX (projections not included) 2932(W)41332(H)1316(D) in 2
U.S.A.
144148 136174*
Weight (approx.) 3
AUS (without battery pack/case and ant.) : 140 g; 4.9 oz

CHN 4
136174* 136174* D Transmitter
EXP
Modulation system : Variable reactance freq. modulation
5
EUR
UK 144146 144146
Output power (at 7.2 V DC) : High 5.5 W, Mid. 2.5 W, Low 0.5 W. 6
Max. frequency deviation : FM (wide) 5.0 kHz
KOR
FM (narrow) 2.5 kHz 7
* Guaranteed: Only 144148 MHz range Spurious emissions : Less than 60 dBc 8
Mode : FM, FM-N External mic. connector : 3-conductor 2.5 (d) mm (110)/2.2 k
Number of memory channels : 207 9
D Receiver
(incl. 6 scan edges and 1 Call channel)
10
Usable temperature range : 20C to +60C; 4F to +140F Receive system : Double-conversion superheterodyne
Tuning steps : 5, 10, 12.5, 15, 20, 25, 30 and Intermediate frequencies : 1st: 21.7 MHz, 2nd: 450 kHz 11
50kHz Sensitivity (at 12 dB SINAD) : 0.14 V typ.
Frequency stability : 2.5 ppm Squelch sensitivity (threshold) : 0.1 V typ.
12
(20C to +60C; 4F to +140F) Selectivity : FM (wide) 70 dB typ. 13
Power supply : Icom specified battery pack/case FM (narrow) 50 dB typ.
Current drain (at 7.2 V DC: typical) Spurious and image rejection : 75 dB typ. 14
Transmit at 5.5 W (High) : 1.4 A Intermodulation : FM (wide) 70 dB typ. 15
at 2.5 W (Mid.) 0.9 A FM (narrow) 65 dB typ.
at 0.5 W (Low) 0.6 A Audio output power (at 10% distortion) 16
Receive standby : 65 mA Internal speaker : 0.75 W typ. with a 16 load
power save 20 mA External speaker : 0.45 W typ. with a 8 load
17
max. audio 310 mA (internal speaker) External speaker connector : 3-conductor 3.5(d) mm; (18)/8 18
180mA (external speaker)
Antenna connector : BNC (50 W) All stated specifications are subject to change without notice or 19
obligation.
54
16 CE

IMPORTANT
When transmitting with a portable radio, hold the radio in List of Country codes (ISO 3166-1)
a vertical position with its microphone 2.5 to 5 centimetres
from your head and body. Country Codes Country Codes
1 Austria AT 18 Liechtenstein LI
If you wear a portable two-way radio on your body, ensure 2 Belgium BE 19 Lithuania LT
that the antenna is at least 2.5 centimetres from your body 3 Bulgaria BG 20 Luxembourg LU
when transmitting. 4 Croatia HR 21 Malta MT
5 Czech Republic CZ 22 Netherlands NL
C
 E Versions of the IC-V80E which display 6 Cyprus CY 23 Norway NO
the CE symbol on the serial number label, 7 Denmark DK 24 Poland PL
comply with the essential requirements of the 8 Estonia EE 25 Portugal PT
European Radio and Telecommunication Ter- 9 Finland FI 26 Romania RO
minal Directive 1999/5/EC. 10 France FR 27 Slovakia SK
11 Germany DE 28 Slovenia SI
This warning symbol indicates that this equip- 12 Greece GR 29 Spain EP
ment operates in non-harmonised frequency 13 Hungary HU 30 Sweden SE
bands and/or may be subject to licensing con- 14 Iceland IS 31 Switzerland CH
ditions in the country of use. Be sure to check 15 Ireland IE 32 Turkey TR
that you have the correct version of this radio 16 Italy IT 33 United Kingdom GB
or the correct programming of this radio, to 17 Latvia LV
comply with national licensing requirements.

55
CE 16

1
2
DECLARATION
3
OF CONFORMITY
4
We Icom Inc. Japan 5
1-1-32, Kamiminami, Hirano-ku
Osaka 547-0003, Japan 6
Declare on our sole responsibility that this equipment complies with the
Dsseldorf 16th Oct. 2009
7
Place and date of issue
essential requirements of the Radio and Telecommunications Terminal
Equipment Directive, 1999/5/EC, and that any applicable Essential Test 8
Icom (Europe) GmbH
Suite measurements have been performed.
Himmelgeister strae 100 9
Kind of equipment: VHF TRANSCEIVER D-40225 Dsseldorf
10
Authorized representative name
Type-designation: iV80E 11
Version (where applicable):
Y. Furukawa
General Manager
12
This compliance is based on confor mity with the following har monised 13
standards, specifications or documents:
14
i) EN 301 489-1 v1.8.1 (Apr. 2008)
ii) EN 301 489-15 v1.2.1 (Aug. 2002) 15
iii) EN 301 783-2 v1.1.1 (Sep. 2000) Signature 16
iv) EN 60950-1 (2001): A11: 2004
17
18
19
56
#02 Europe <Intended Country of Use>
#12 Europe-21 AT BE CY CZ DK EE
#22 Europe-22 FI FR DE GR HU IE
#32 Europe-23 IT LV LT LU MT NL
PL PT SK SI ES SE
GB IS LI NO CH BG
RO TR HR

#13 U.K.-01 <Intended Country of Use>


#23 U.K.-02 AT BE CY CZ DK EE
#33 U.K.-03 FI FR DE GR HU IE
IT LV LT LU MT NL
PL PT SK SI ES SE
GB IS LI NO CH BG
RO TR HR

A-6795H-1EX-w
Printed in Japan
20092010 Icom Inc. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
Printed on recycled paper with soy ink.

You might also like