Professional Documents
Culture Documents
Received February 14, 1996. Revised Manuscript Received December 23, 1996X
Structural characterization studies have been carried out on four commercial Saudi Arabian
crude oils. The aromaticity and crystallite parameters of the asphaltenes were studied by X-ray
diffraction methods and compared to the average structural parameters calculated from nuclear
magnetic resonance spectra.
Introduction The crude oils produced by the Saudi Arabian Oil Co.
(Saudi Aramco) are marketed under the following
The long-term future outlook for the hydrocarbon names:
conversion industry is to utilize the heavier and more Arabian Extra Light, which comes from the Berri,
carbonaceous feedstocks. Such feedstocks are charac- Saudi Arabia, field and is produced from the upper
teristically more difficult to process because they contain Jurassic age Arab zone reservoirs, generally oolitic and
substantial amounts of asphaltenes. Asphaltenes are dolomitic limestones. It is a relatively high API gravity
defined as materials insoluble in aliphatic hydrocarbon (38.50 API) and low-sulfur, paraffinic-type crude oil.
solvents (n-pentane and n-heptane). In general, as- Arabian Light is produced from the Ghawar field,
phaltenes have higher aromaticity, heteroatom contents, which is the largest onshore oil field in the world, and
metal contents, and molecular weights as compared to it is also derived from the upper Jurassic age Arab zone
lighter petroleum fractions and are thereby commonly reservoirs. Arabian Light is a moderately high-gravity
presumed to represent the most refractory and difficult (33.80 API), medium-sulfur, and medium-paraffinic
portion of the feedstocks to process. The molecular crude oil.
species that constitute asphaltenes have been a subject Arabian Medium is produced from the Jurassic age
of active research over the past 30 years. These Arab zone reservoirs as a multistage separated oil from
investigations have brought to light some significant a blend of the following fields: 65% Khursaniya, 25%
facts about asphaltene structure. There is a general Qatif, and 10% Abu-Safah. This crude oil is a medium-
consensus of the majority of the researchers that as- gravity (30.40 API) paraffinic wax-containing crude oil.
phaltene contains condensed aromatic systems carrying Arabian Heavy is a relatively low-gravity (28.03
alkyl, cycloalkyl, and heteroatom constituents.1-3 API), high-sulfur, paraffinic wax-containing crude oil.
The structural characteristics of asphaltenes are It comprises crude oil from an offshore field, Safaniya,
important to refiners for determining the yields from located about 125 mi northwest of the exporting termi-
the residual fraction of crude oils and the operating nal Ras Tanura and is known to be the worlds largest
parameters of the process units for deep conversion offshore oil field. Safaniya oil is produced from the
processes. Two established techniques for determining lower Cretaceous age Arab zone reservoirs.
structural characteristics are X-ray diffraction and All crude oil leaving the Saudi Aramco production
nuclear magnetic resonance (NMR). In this paper, we fields, with the exception of those at Safaniya, Marjan,
and Zuluf, are sour and contain toxic hydrogen sulfide.
report the structural characterization of four Saudi
Sour crude is sweetened, stabilized, and pumped to the
Arabian crude-oil-derived asphaltenes by X-ray diffrac-
storage facilities before shipment. All crude oil samples
tion and we discuss the data in combination with
studied in this work are stabilized crude from the
previous NMR results on the same asphaltenes.4 In an
storage facilities in Ras Tanura.
attempt to explain the relatively higher aromaticity of
Arab Berri asphaltenes, high-pressure gel permeation
Experimental Section
chromatography (HP-GPC) is used to characterize Arab
asphaltenes in terms of their molecular size distribution The residue was prepared by removing distillates boiling
in solution. up to 370 C using a Podbielniak column for atmospheric-
pressure and vacuum distillation using ASTM method D 2892.5
* To whom correspondence should be addressed.
Isolation of Asphaltenes. Asphaltenes were isolated from
The Research Institute, KFUPM, Dhahran. the 370 C residue by digesting 45 g of residue with 1350 mL
X Abstract published in Advance ACS Abstracts, March 1, 1997. (30-fold volume) of normal pentane solvent. The mixture was
(1) Speight, J. G. The Chemistry and Technology of Petroleum; stirred for 90 min at 1500 rpm and then allowed to stand for
Marcel Dekker Inc.: New York, 1991.
(2) Mushrush, G. W.; Speight, J. G. Petroleum products: Instability
16 h at room temperature. It was then transferred into 100
and Incompatibility; Taylor and Francis: Washington, DC, 1995.
(3) Speight, J. G.; Long, R. B. Fuel Sci. Technol. Int. 1996, 14 (1 & (5) Annual Book of ASTM Standards; American Society for Testing
2), 1-12. and Materials: Philadelphia, PA, 1995; Standard No. D 2892, Vol.
(4) Hasan, M.; Ali, M. F.; Bukhari, A. Fuel 1983, 62, 518. 05.02.
mL centrifuge tubes and centrifuged for 60 min at 1600 rpm. Table 1. Aromaticity and Crystallite Parameters of Four
The supernatant liquids (maltenes) were decanted, and the Saudi Crude Asphaltenes
mixture was recentrifuged with fresh volumes of normal asphaltene
aromaticity and
pentane to wash the asphaltenes. Asphaltenes were collected crystallite Arab Arab Arab Arab
from the bottom of the centrifuge tubes and then purified by parameters Heavy Medium Light Berri
extraction for 24 h with normal pentane on a Soxhlet extractor
fa 0.19 0.16 0.19 0.20
at ambient temperature, followed by drying in a vacuum oven
dm, 3.6 3.6 3.6 3.6
at 50 C and 2.5 kPa pressure. d, 4.4 4.5 4.4 4.4
Elemental analyses. Elemental analyses of all four as- La, 12.3 11.9 13.0 13.0
phaltene samples were performed on a Carlo Erba 1106 Lc, 24.7 23.2 24.0 22.7
elemental analyzer. M 8.0 7.5 7.8 7.4
HP-GPC analyses. The HP-GPC procedure utilized a The method of obtaining the aromaticity and crystallite
Waters HPLC system 840, with a Model 501 pump, 712 WISP parameters is found elsewhere,10,11 and is summarized as
auto injector, R-401 differential refractometer detector, and a follows:
Millennium 2010 chromatography manager for recording A comparative estimate of the aromaticity fa was determined
chromatograms and accumulating data. The column bank by calculating the areas A of the resolved peaks for the and
consisted of four Millipore Ultrastyragel columns in series: graphene bands using the following formula:
10 000, 1000, 500, and 100 . The mobile phase was HPLC-
grade tetrahydrofuran (THF) at a flow rate of 1.00 mL/min. fa ) CA/C ) CA/(CA + CS) ) A(graphene)/(A(graphene)+A()) (1)
About 100 mg of an asphaltene sample was dissolved in 10
mL of THF at room temperature, then filtered through a 0.2 where CS, CA, and C are the number of saturated, aromatic,
mm membrane and an exact volume (100 L) was injected into and total carbon atoms per structural unit.
the HP-GPC system. The GPC profiles and molecular weights The layer distance between aromatic sheets was calculated
were calculated using the Millennium 2010 computer program. from the maximum of the graphene band by the Bragg
X-ray Diffraction. X-ray diffraction measurements were relation:
made on finely ground powders (about 50-200 m which were
ground by mortar and pestle and checked on a JEOL 840 dm ) /(2 sin ) (2)
scanning electron microscope, SEM) of asphaltene with a
Philips PW1700 automated diffractometer. In this ground where is the wavelength of the Cu KR radiation and is the
powdered form, many grains come into orientation and the Bragg angle.
quality of the diffraction pattern is greatly improved. The The distance between the saturated portions of the mol-
instrument has a vertical goniometer attached to a broad-focus ecules or interchain layer distance is given by this relationship:
X-ray tube with a copper target operating at 40 kV and 40
d ) 5/(8 sin ) (3)
mA and a graphite monochromator. An autodivergent slit, 0.1
mm receiving slit, scan rate 0.01 2 s-1 and count time of 5
The average diameter of the aromatic sheets on the basis
s/step were employed. The analysis is computer assisted so
of the Scherrer crystallite size formula is as follows:
that the interplanar spacing values can be corrected for the
instrument error function by analyzing a silicon standard. The La ) 1.84/( cos ) ) 0.92/B1/2 (4)
computer was also used to perform peak profile analysis. The
profile fitting was used to accurately determine peak positions, where B1/2 is the full width at half-maximum using the (11)
widths (full width at half-maximum, fwhm), backgrounds, band and is the bandwidth.
intensities, and net peak areas calculated. The technique The average height of the stack of aromatic sheets perpen-
involves specifying a mathematical model to represent the dicular to the plane of the sheet was calculated from the full
expected profile shape.6 The profile fitting uses a model that width of the graphene band at half-maximum using the
employs 12 intrinsic parameters to describe the profile, the equation
instrument aberrations, and wavelength-dependent contribu-
tions to the profile. These contributions are systematic with Lc ) 0.9 cos ) 0.45/B1/2 (5)
2. They are determined with an initial estimate of the KR 1
peak position and intensity. The model also utilizes three The number of aromatic sheets in a stacked cluster, M, was
parameters to describe the sample-dependent parameters: calculated from the values of Lc and dm as follows:
angle position, intensity, and line broadening. These are fitted
to the experimental diffraction profile using a Marquardt M ) (Lc/dm) + 1 (6)
nonlinear least-squares algorithm.7 The profile fitting stops
when convergence has been reached. Convergence is reached Results and Discussion
when the difference in the -squared value between two
iterations became equal to or less than 0.3. In the case of The results obtained by calculating all of the param-
measuring the net peak areas of the and graphene peaks, eters from X-ray measurements of the four Saudi crude
the areas of the peak profile are measured at reduced intensity asphaltenes are summarized in Table 1. The doublet
(background subtracted) over the range required (11-33 2) of the and graphene layer stacking peaks at about 20
as described by the authors.8,9 and 25 ) 2 has been determined for each sample and
their peak profiles were fitted.
(6) PC-APD Version 3.6, Software for Automated Powder Diffraction The results indicate that the average layer distance
- Operation Manual, Fifth Edition, Philips Analytical X-Ray, Eind- between aromatic sheets (dm) measures about 3.6 , the
hoven, The Netherlands, February 1994, pp 611-615.
(7) Schreiner, W. N.; Jenkins, R. Profile fitting for Quantitative average interchain layer distance (d) is between 4.4 and
Analysis in X-Ray Powder Diffraction. Adv. X-Ray Anal. 1983, 26, 141.
(8) Schwager, I.; Farmanlan, P. A.; Kwan, J. T.; Weinberg, V. A.; (10) Yen, T. F., Erdman, J. G.; Pollack, S. Anal. Chem. 1961, 33,
Yen, T. F. Anal. Chem. 1983, 55, 42. 1587.
(9) Yen, T. F. Multiple Structural Orders of Asphaltenes. In As- (11) Wen, C. S.; Chilingarian, G. V.; Yen, T. F. Properties and
phaltenes and Asphalts, 1. Developments in Petroleum Sciences; Yen, Structure of Bitumens. In Bitumens, Asphalts and Tar Sands; Chil-
T. F., Chilingarian, G. V., Eds.; Elsevier Sci. Publ.: New York, 1994; ingarian, G. V., Yen, T. F., Eds.; Developments in Petroleum Science
Vol 40, Chapter 5, p 111 and references therein. 7; Elsevier Sci. Publ.: Amsterdam, 1978; Chapter 7, 155.
Saudi Crude Asphaltenes Energy & Fuels, Vol. 11, No. 3, 1997 563