You are on page 1of 2
c.08at INSTALLATIONS ‘cROSS561AT10N5 Ped ADOR CORONA TR SETS Capac koma) Input Voltage 415 Volts (PHASE - PHASE) 380V, 400V, 440V, 460V, 500V, 575V, 660V & 690V Variation + 10% Frequency 50Hz / 60 Hz +/-5% Output Voltage 30KV (P) to 200KV (P) On No Load at nominal rated UP voltage Output Current ‘50mA to 4000mA Avg (mean) DC Design Form Factor 4.2/4.3 1.4 MAX Design Ambient Temp “30°C to +55°C \ Both Not Humidity 400% (Occurring Simultaneously Various Configurations of Possible Ambient | 40/45/50/55C with top oll temperature rise limited to 65/50/45/40C Bushing Orientation Horizontal/ Vertical ‘Method of Cooling: Control Panel Natural! Forced air cooled -TIR Set ll Natural Air Natural Coolant: Mineral Oil Silicon Oil ADOR POWERTRON LTD. The pulse of technology in Power Electronics from India with installations of High Voltage Rectiformers all over the world in the Power, Cement, Steel and Paper Industries BYTES sake : '* Hetmeticaly sealedconstruction ‘© HV Transformer, Rectifier, AC Reactor & Choke Assembly is lid mounted for convenience andease of maint ance andrepairs. ‘ Conforms to Ingress Protection class IP-65 as per IEC PUB 947-1, Doubly i ‘Wound, crass ever winding with electrostatic shield between primary and econdary, ‘* High Frequency Choke for surge protection of rectifier stack diodes. ‘* High Voltage resistors for better stabilty and shield for induction fee signal wavelor, | ‘© HV Rectiier Stack design consists of special glass sealed passivated avalanche diodes, wih controlled avalanche characteristics, which conduct the currents associated with transient waves in their reverse biased direction without being destroyed in the way that normal diodes are, thus ensuring highest possible immunity totraveling waves, '* Standard Protections Include: Current Limiting Reactor, High Frequency Choke, Dial Thermometer, Pressure Release Valves, Pressure Switch, Oil Level Gauge. ESP CONTROLS: SALIENT FEATURES OF ADOR CORONA CONTROL CABINET WITH PRECICON CONTROLS FOR ELECTROSTATIC PRECIPITATOR APPLICATIONS. '* Improved collection efficiency. ‘* Energy saving feature based on VI characteristic. ‘* Additional optimisation modes: a) Charge ratio. b) Back corona, '* Load status mode: Enabling selection between different operating parameter values for varying plant conditions. ‘© Serialinterface for communication ‘ Inbuilt rapping motor control feature for upto four independent rapper motors, '* Computer aided ESP controimanagement system Cee ees '* Fully customised control cabinets ‘¢ Interfacing option with all available ESP controller makes. © Easy Retrofits * Options for stand alone panels as well as cascaded arrangement. [aor] ADOR POWERTRON LIMITED [rsa eecasrenes Cocian] Se coote rromeeronye woecaeus MICS ee nous BERR POWERTRON Fax: +91-20-27475817 E-Mail: cmo@adorpower.com; ih a cas

You might also like