Professional Documents
Culture Documents
/2.2:A
/2.4:B
2 4 6
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
AUX. TRIP 1 3
CONT. CONT.
L_24V / 1.3:D
QC2
L_0V / 1.2:D
L09 / 3.2:D
L13 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L14 / 2.8:C
L08 / 3.2:C
L28 / 2.5:C
L12 / 2.7:C
L11 / 2.7:C
MCB DP 2 4
4A
R49_2 / 2.2:D
R49_1 / 2.2:C
Cb_1 / 1.4:D
Ca_1 / 1.4:D
B B
LCS R-SELECTED
PCS OPERATED
BSS OPERATED
COMMON DM
LCS EM STOP
LCS START
LCS STOP
TO RUN
SPARE
1.2:D / L23
1.2:D / L24
PROFIBUS
ZSS
COMMUNICATION
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
1 3
PAN
QC3
MCB DP 2 4
6A
TO TRIP
X5 X5
CONTACTOR ON
101 102
4-20mA OUTPUT
13 43
SPARE
READY
2.4:B / R49_3
2.4:B / R49_4
SPARE
K5 K5
/2.4:D 14 /2.4:D 44 D
D
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
3.8:B / L04
1.8:B / L23
1.8:B / L24
3.7:B / L01
1.2:B / Ca_1
1.2:B / Cb_1
3.7:B / L02
3.8:B / L03
2.3:B / R49_6
2.3:B / R49_9
1 3 5 HOOTER
K01
/2.3:D 2 4 6 240VAC AUX.
SUPPLY L51 L52
3.5:A 3.5:A
X0 R Y B
TO HOOTER
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
PE POWER CIRCUIT MNS DRG. NO : MNS03000220P050 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 26 X1 28 X1 35
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
13 43 21 13
L15
K01 K01A K01A K1
INTERLOCK
3.2:A PCS BSS SPARE
FUTURE
/2.3:D 14 /2.2:D 44 /2.2:D 22 /2.3:D 14
EMG
STOP
3.4:A X1 27 X1 29 X1 36
X1 8
R49_6 R49_3
B L16 B
1.5:D 95 1.6:D
Q1
21
FROM UMC (TRIP 96 98
FROM UMC
13 CONT.)
K1 1.5:D 1.6:D
TPB /2.3:D 22
/2.2:E 14 R49_9 R49_4
TEST X1 10
PB
2.8:D
INTERLOCK
YELLOW
FUTURE
L35
X1 11
C C
L17 L28 L18 L11 L12 L14
3.5:A 1.6:B 3.6:A 1.6:B 1.6:B 1.5:B
ZSS
TO LCS TRIP PCS OPERATED BSS OPERATED
R49_1 SUPPLY SPARE
1.3:B
INDICATION FROM GCP FROM GCP
13
UMC RUN K01A 3.2:D 1.5:B 2.3:C
1.3:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 -K5 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2
L50 / 1.8:C
ON CONT. FWD.ON TRIP HOOTER ON OFF TRIP TO LCS TRIP READY
MULTI. 1 2 /1.1:D 13 14 /2.6:B 13 14 /1.8:D INDICATION 13 14 /3.8:B
23
13 14 /2.3:D 3 4 /1.2:D 21 22 /2.2:B 21 22 /3.7:D 21 22 /3.8:C
TPB 31 32 /3.7:C 31 32 /3.7:D 31 32 /3.8:C
21 22 /2.6:B 5 6 /1.2:D
/2.2:B 24
31 32 /3.8:D 13 14 /2.5:B 43 44 /3.7:C 43 44 /1.8:D 43 44 /3.8:C
TEST
E PB 43 44 /2.5:B E
53 54 /3.7:B
63 64 /3.8:D R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
SPARE CONTACT R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L51 / 1.8:D
L52 / 1.8:D
L17 / 2.5:C
L18 / 2.6:C
L15 / 2.2:B
L16 / 2.2:B
A 1.3:D / L05
A
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
LCS 12 13 15 57 58 14 K01A
/2.2:D 54
SPARE K2
/2.8:D 14
SPARE
(TYPE-A)
25
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF HOOTER L01 L02 L03 L04
CUM 1.3:D 1.3:D 1.3:D 1.3:D
REMOTE FLASHER
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
PCS ZSS
LCS SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
STOP FIELD
X1
16 16
LCS STOP 1.5:B / L06 x1 X1 37 X1 39 X1 41 X1 43 X1 45
TRIP
EMG LAMP
STOP x2
LCS AMBER
31 43 21 31 43
C START
K1 K1 K2 K2 K2 C
X1 /2.3:D 32 /2.3:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44
17 17 TRIP TRIP READY READY READY
LCS START 1.5:B / L07
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49 X1 51 X1 53
X1
20 20
LCS EM STOP 1.5:B / L09
31 21 31 63
K5 K5 K01A K01A
/2.4:D 32 /2.4:D 22 /2.2:D 32 /2.2:D 64
X1
22 22 HOOTER HOOTER CONT. CONT.
D ON ON
D
ZSS 1.6:B / L13
24 X1 48 X1 50 X1 52 X1 54
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FROM 240V AC
UPS SUPPLY BUS
415V +/-10% ,3PH , 4-WIRE , 50Hz +/-5%
R R
A
Y Y
X3 1 X3 2 A
B B
N N
1 3 5
12 14 96 98 1 3
QC2
Q1 I> I> I> 11 95 MCB DP 2 4
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
MCCB
/2.2:A
/2.4:B
4A
2 4 6
AUX. TRIP
CONT. CONT.
L_24V / 1.3:D
L_0V / 1.3:D
L09 / 3.2:D
L13 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L14 / 2.8:C
L08 / 3.2:C
L28 / 2.5:C
L12 / 2.7:C
L11 / 2.7:C
B B
R49_2 / 2.2:D
R49_1 / 2.2:C
Cb_1 / 1.5:D
Ca_1 / 1.5:D
1.3:D / L23
1.3:D / L24
LCS R-SELECTED
PCS OPERATED
BSS OPERATED
COMMON DM
LCS EM STOP
LCS START
LCS STOP
TO RUN
SPARE
PROFIBUS
ZSS
COMMUNICATION
1 3
QC3
MCB DP 2 4
CONTACTOR ON
6A
TO TRIP
SPARE
READY
SPARE
3.6:A / L19
3.6:A / L20
D D
1 3 5 13 43
2.4:B / R49_3
2.4:B / R49_4
K01 K5 K5
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
3.8:B / L04
1.7:B / L23
1.8:B / L24
3.7:B / L01
1.3:B / Ca_1
1.3:B / Cb_1
3.7:B / L02
3.8:B / L03
2.3:B / R49_6
2.3:B / R49_9
(4-20mA)
240VAC AUX. HOOTER
SUPPLY
X0 R Y B
L51 L52
3.5:A 3.5:A
U V W
E
M1
M TO HOOTER E
3~
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
PE
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 26 X1 28 X1 35
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
13 43 21 13
L15
K01 K01A K01A K1
INTERLOCK
3.2:A PCS BSS SPARE
FUTURE
/2.3:D 14 /2.2:D 44 /2.2:D 22 /2.3:D 14
EMG
STOP
3.4:A X1 27 X1 29 X1 36
X1 8
R49_6 R49_3
B L16 B
1.6:D 95 1.6:D
Q1
21
FROM UMC (TRIP 96 98
FROM UMC
13 CONT.)
K1 1.6:D 1.6:D
TPB /2.3:D 22
/2.2:E 14 R49_9 R49_4
TEST X1 10
PB
2.8:D
INTERLOCK
YELLOW
FUTURE
L35
X1 11
C C
L17 L28 L18 L11 L12 L14
3.5:A 1.6:B 3.6:A 1.6:B 1.6:B 1.5:B
ZSS
TO LCS TRIP PCS OPERATED BSS OPERATED
R49_1 SUPPLY SPARE
1.3:B
INDICATION FROM GCP FROM GCP
13
UMC RUN K01A 3.2:D 1.5:B 2.3:C
1.3:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 -K5 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2
L50 / 1.7:C
ON CONT. FWD.ON TRIP HOOTER ON OFF TRIP TO LCS TRIP READY
MULTI. 1 2 /1.1:D 13 14 /2.6:B 13 14 /1.7:D INDICATION 13 14 /3.8:B
23
13 14 /2.3:D 3 4 /1.1:D 21 22 /2.2:B 21 22 /3.7:D 21 22 /3.8:C
TPB 31 32 /3.7:C 31 32 /3.7:D 31 32 /3.8:C
21 22 /2.6:B 5 6 /1.1:D
/2.2:B 24
31 32 /3.8:D 13 14 /2.5:B 43 44 /3.7:C 43 44 /1.7:D 43 44 /3.8:C
TEST
E PB 43 44 /2.5:B E
53 54 /3.7:B
63 64 /3.8:D R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
SPARE CONTACT R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L17 / 2.5:C
L18 / 2.6:C
L15 / 2.2:B
L16 / 2.2:B
L51 / 1.7:E
L52 / 1.7:E
A 1.3:D / L05
A
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 X5 101 X5 102 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
25
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF HOOTER L01 L02 L03 L04
CUM 1.3:D 1.3:D 1.4:D 1.4:D
REMOTE FLASHER
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
PCS ZSS
LCS SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
STOP FIELD
X1
16 16
LCS STOP 1.5:B / L06 x1 X1 37 X1 39 X1 41 X1 43 X1 45
TRIP
EMG LAMP
A
STOP x2
LCS AMBER
31 43 21 31 43
C START
K1 K1 K2 K2 K2 C
X1 /2.3:D 32 /2.3:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44
17 17 TRIP TRIP READY READY READY
LCS START 1.5:B / L07
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49 X1 51 X1 53
X1
20 20
LCS EM STOP 1.6:B / L09
31 21 31 63
K5 K5 K01A K01A
/2.4:D 32 /2.4:D 22 /2.2:D 32 /2.2:D 64
X1
22 22 HOOTER HOOTER CONT. CONT.
D ON ON
D
ZSS 1.6:B / L13
24 X1 48 X1 50 X1 52 X1 54
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X0
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X2
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X3
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01 DOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X5
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER(FROM 37KW-110KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FROM 240V AC
UPS SUPPLY BUS
415V +/-10% ,3PH , 4-WIRE , 50Hz +/-5%
R R
A
Y Y
X3 1 X3 2 A
B B
N N
1 3 5
12 14 96 98 1 3
QC2
Q1 I> I> I> 11 95 MCB DP 2 4 L
PH PH
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
MCCB
/2.2:A
/2.4:B
4A
2 4 6
N
AUX. TRIP
N N
CONT. CONT.
L_24V / 1.3:D
L_0V / 1.3:D
L09 / 3.2:D
L13 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L14 / 2.8:C
L08 / 3.2:C
L28 / 2.5:C
L12 / 2.7:C
L11 / 2.7:C
B X4 1 X4 2
B
R49_2 / 2.2:D
R49_1 / 2.2:C
Cb_1 / 1.5:D
Ca_1 / 1.5:D
1.3:D / L23
1.3:D / L24
1 3
QC4
LCS R-SELECTED
PCS OPERATED
BSS OPERATED
MCB DP 2 4
COMMON DM
LCS EM STOP
6A
LCS START
LCS STOP
TO RUN
SPARE
PROFIBUS
ZSS
COMMUNICATION 71
K01A
R49 BUS -B1 /2.2:D 72
T1 T2 Ca Cb C C DO0 DO1 DO2 0V 24VDC 1DIZ 1DI0 1DI1 1DI2 1DI3 1DI4 2DIZ 2DI5 2DI6 2DI7
C READY C
READY
MOTOR ON
P1 S1 P1 S1 P1 S1 Inputs DI 230VAC DOOR DIGITAL
DIAG
CT4 FAULT
UMC 100.3 ERROR
Relay DO
230VAC/1A
DX122 DISPLAY
P2 S2 P2 S2 P2 S2
Prozessor 2.8:A 2.8:D
X4 3 X4 4
L49 L50
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
1 3 M1_1 M1_2
QC3 1.2:E 1.2:E
MCB DP 2 4
CONTACTOR ON
6A MOTOR
TO TRIP
SPACE HEATER
SPARE
READY
SPARE
3.6:A / L19
3.6:A / L20
D D
1 3 5 13 43
2.4:B / R49_3
2.4:B / R49_4
K01 K5 K5
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
3.8:B / L04
1.7:B / L23
1.7:B / L24
3.7:B / L01
1.3:B / Ca_1
1.3:B / Cb_1
3.7:B / L02
3.8:B / L03
2.3:B / R49_6
2.3:B / R49_9
(4-20mA)
240VAC AUX. HOOTER
SUPPLY
X0 R Y B
L51 L52
3.5:A 3.5:A
U V W M1_1 / 1.8:C
x1 HE1
E M SPACE
MOTOR TO HOOTER E
M1 SPACE HEATER
3~ x2
HEATER
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
PE M1_2 / 1.8:C
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01S DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(ABOVE 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 26 X1 28 X1 35
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
13 43 21 13
L15
K01 K01A K01A K1
INTERLOCK
3.2:A PCS BSS SPARE
FUTURE
/2.3:D 14 /2.2:D 44 /2.2:D 22 /2.3:D 14
EMG
STOP
3.4:A X1 27 X1 29 X1 36
X1 8
R49_6 R49_3
B L16 B
1.6:D 95 1.6:D
Q1
21
FROM UMC (TRIP 96 98
FROM UMC
13 CONT.)
K1 1.6:D 1.6:D
TPB /2.3:D 22
/2.2:E 14 R49_9 R49_4
TEST X1 10
PB
2.8:D
INTERLOCK
YELLOW
FUTURE
L35
X1 11
C C
L17 L28 L18 L11 L12 L14
3.5:A 1.6:B 3.6:A 1.6:B 1.6:B 1.5:B
ZSS
TO LCS TRIP PCS OPERATED BSS OPERATED
R49_1 SUPPLY SPARE
1.3:B
INDICATION FROM GCP FROM GCP
13
UMC RUN K01A 3.2:D 1.5:B 2.3:C
1.3:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 -K5 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2
L50 / 1.7:C
ON CONT. FWD.ON TRIP HOOTER ON OFF TRIP TO LCS TRIP READY
MULTI. 1 2 /1.1:D 13 14 /2.6:B 13 14 /1.7:D INDICATION 13 14 /3.8:B
23
13 14 /2.3:D 3 4 /1.1:D 21 22 /2.2:B 21 22 /3.7:D 21 22 /3.8:C
TPB 31 32 /3.7:C 31 32 /3.7:D 31 32 /3.8:C
21 22 /2.6:B 5 6 /1.1:D
/2.2:B 24
31 32 /3.8:D 13 14 /2.5:B 43 44 /3.7:C 43 44 /1.7:D 43 44 /3.8:C
TEST
E PB 43 44 /2.5:B E
53 54 /3.7:B
63 64 /3.8:D R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
SPARE CONTACT 71 72 /1.8:C R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01S DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(ABOVE 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L17 / 2.5:C
L18 / 2.6:C
L15 / 2.2:B
L16 / 2.2:B
L51 / 1.7:E
L52 / 1.7:E
A 1.3:D / L05
A
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 X5 101 X5 102 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
25
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF HOOTER L01 L02 L03 L04
CUM 1.3:D 1.3:D 1.4:D 1.4:D
REMOTE FLASHER
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
PCS ZSS
LCS SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
STOP FIELD
X1
16 16
LCS STOP 1.5:B / L06 x1 X1 37 X1 39 X1 41 X1 43 X1 45
TRIP
EMG LAMP
A
STOP x2
LCS AMBER
31 43 21 31 43
C START
K1 K1 K2 K2 K2 C
X1 /2.3:D 32 /2.3:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44
17 17 TRIP TRIP READY READY READY
LCS START 1.5:B / L07
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49 X1 51 X1 53
X1
20 20
LCS EM STOP 1.6:B / L09
31 21 31 63
K5 K5 K01A K01A
/2.4:D 32 /2.4:D 22 /2.2:D 32 /2.2:D 64
X1
22 22 HOOTER HOOTER CONT. CONT.
D ON ON
D
ZSS 1.6:B / L13
24 X1 48 X1 50 X1 52 X1 54
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103 X4 5
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D01S DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(ABOVE 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X0
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X2
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X3
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X4
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
5 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X4
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D01S DOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X5
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D01S DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 11 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
/2.2:A
/2.5:B
2 4 6
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
AUX. TRIP 1 3
CONT. CONT.
QC2
L_24V / 1.3:D
L_0V / 1.2:D
MCB DP
L14 / 3.2:D
L09 / 3.2:D
L13 / 3.2:D
L10 / 2.7:D
2 4
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L12 / 2.8:C
L28 / 2.6:C
L11 / 2.7:C
R49_1 / 2.2:C
R49_2 / 2.2:C
4A
B B
BRAKE RELEASED
LCS R-SELECTED
L1 / 1.7:C
PCS OPERATED
BSS OPERATED
TO RUN
COMMON DM
LCS EM STOP
L2 / 1.7:C
Cb_1 / 1.4:D
Ca_1 / 1.4:D
LCS START
L3 / 1.7:C
LCS STOP
1.2:D / L23
1.2:D / L24
PROFIBUS
ZSS
COMMUNICATION
L1 / 1.2:B
L2 / 1.2:B
L3 / 1.2:B
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3 1 3
PAN QC3
MCB DP 2 4
6A
CONTACTOR ON
TO TRIP
1 3 5
X5 X5 13
Q2
101 102 MPCB,3P I> I> I> 13 43
SPARE
14
READY
SPARE
2 4 6 K5 K5
2.3:B / R49_4
2.3:C / R49_3
2.4:C / R49_31
/2.2:A
4-20mA OUTPUT /2.3:D 14 /2.3:D 44
1 3 5
D D
K03
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
3.8:B / L04
1.8:B / L23
1.8:B / L24
/2.4:D
3.7:B / L01
1.2:C / Ca_1
1.2:C / Cb_1
2 4 6
3.7:B / L02
3.8:B / L03
2.4:B / R49_6
2.4:B / R49_9
X0 R1 Y1 B1
TO BRAKE DISENGAGE
1 3 5
& HOOTER
K01 240VAC AUX. TO DC EM
/2.3:D 2 4 6 SUPPLY BRAKE
PANEL L51 L52
3.5:A 3.6:A
X0 R Y B
TO HOOTER
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
PE POWER CIRCUIT MNS DRG. NO : MNS03000220P052 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D02 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 7
13 43 21 13
L15
K01 K01A K01A K1
INTERLOCK
FUTURE
3.2:A PCS BSS
/2.3:D 14 /2.2:D 44 /2.2:D 22 /2.4:D 14
3.4:A
L16 R49_4 X1 27 X1 29
X1 8
1.6:D R49_6
B B
21 1.5:D 95
K1 Q1
FROM UMC (TRIP 96 98
13 /2.4:D 22
CONT.)
TPB X1 10 1.5:D
2.8:D
/2.2:E R49_9
INTERLOCK
14 L35
FUTURE
TEST
PB
YELLOW
X1 11
FROM UMC FROM UMC
TO HOOTER TO BRAKE
1.6:D 1.6:D
C R49_3 R49_31 C
R49_1 L17 L28 L18 L11 L12
1.3:B 3.5:A 1.6:B 3.6:A 1.6:B 1.6:B
13
UMC RUN ZSS
1.3:B
K01A TO LCS TRIP PCS OPERATED BSS OPERATED
/2.2:D 14 SUPPLY
R49_2 INDICATION FROM GCP FROM GCP
3.2:E 1.5:B 2.2:B
L25 L10 L35
L29
COMMON DM
3.5:A
FROM BRAKE
D RELEASE CONTACT D
3.5:A
L30
x1 x1 x1
A1 A1 A1 A1 A1
A1 H1 H2 H3
K01 -K5 -K03 -K1 RED x2 GREEN x2 AMBER x2
-K2
-K01A A2 A2 A2 A2 A2
A2
L50 / 1.8:C
READY
ON CONT. FWD.ON HOOTER BRAKE TRIP ON OFF TRIP TO LCS TRIP 13 14 /3.8:B
23
E MULTI. 1 2 /1.1:D INDICATION 21 22 /3.8:C E
TPB 13 14 /2.3:C
13 14 /1.8:D 1 2 /1.7:D 13 14 /2.6:B
31 32 /3.8:C
/2.2:B 24 3 4 /1.2:D 21 22 /3.7:D 3 4 /1.7:D 21 22 /2.2:B
21 22 /2.6:B R6 03.03.2017 AS MANUFACTURED RJ43 44
KJ /3.8:C DNR
TEST 5 6 /1.2:D 31 32 /3.7:D 5 6 /1.7:D 31 32 /3.7:C
PB 31 32 /3.8:D 13 14 /2.5:B 43 44 /1.8:D 43 44 /3.7:C R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
43 44 /2.5:B 13 14 /3.8:D
53 54 /3.7:B 21 22 /3.8:D MNS DRG. NO : MNS03000220P052 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
SPARE CONTACT 63 64 /3.8:D NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D02 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L29 / 2.2:D
L30 / 2.2:D
L51 / 1.8:D
L52 / 1.8:D
L17 / 2.5:C
L15 / 2.2:B
L16 / 2.2:B
L18 / 2.7:C
A 1.3:D / L05
A
X1 12 X1 13 X1 15 X1 41 X1 42 X1 57 X1 58 X1 14 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
LCS 12 13 15 41 42 57 58 14 K01A
/2.2:D 54
SPARE K2
/2.8:D 14
SPARE
(TYPE-D)
13 30
X2 34 X2 32
25
S2 1 2
B B
LOCAL
OFF HOOTER L01 L02 L03 L04
CUM 1.3:D 1.3:D 1.3:D 1.3:D
REMOTE FLASHER
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
PCS ZSS BRAKE RELEASED
LCS CONTACTS FROM SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
STOP FIELD
BRAKE LSW
X1
16 16
LCS STOP 1.5:B / L06 X1 37 X1 39 X1 31 X1 33 X1 45
EMG
STOP x1
LCS TRIP 31 43 21 31 43
C START
LAMP x2 K1 K1 K2 K2 K2 C
X1 AMBER /2.4:D 32 /2.4:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44
17 17 TRIP TRIP READY READY READY
LCS START 1.5:B / L07
X1
19 19 X1 38 X1 40 X1 32 X1 34 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49 X1 51 X1 53 X1 35 X1 43
X1
20 20
LCS EM STOP 1.5:B / L09
31 21 31 63 21 13
X1 K5 K5 K01A K01A K03 K03
23 23 /2.3:D 32 /2.3:D 22 /2.2:D 32 /2.2:D 64 /2.4:D 22 /2.4:D 14
BRAKE LSW 1.5:B / L14 HOOTER HOOTER CONT. CONT. CONT. CONT.
D
D ON ON ON ON
X1
22 22
ZSS 1.6:B / L13
X1 48 X1 50 X1 52 X1 54 X1 36 X1 44
24
X1
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 105
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D02 DOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X0
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X2
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X3
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X5
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(UPTO 36KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 11 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FROM 240V AC
UPS SUPPLY BUS
1 3 5
12 14 96 98
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
/2.2:A
/2.5:B
2 4 6
AUX. TRIP
CONT. CONT.
1 3
L_24V / 1.3:D
QC2
L_0V / 1.3:D
B B
L14 / 3.2:D
L09 / 3.2:D
L13 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L12 / 2.8:C
L28 / 2.6:C
L11 / 2.7:C
MCB DP 2 4
R49_1 / 2.2:C
R49_2 / 2.2:C
4A
L1 / 1.7:D TO DC EM
L2 / 1.7:D BRAKE
BRAKE RELEASED
L3 / 1.7:D PANEL
LCS R-SELECTED
PCS OPERATED
BSS OPERATED
COMMON DM
LCS EM STOP
TO RUN
Cb_1 / 1.5:D
Ca_1 / 1.5:D
LCS START
LCS STOP
1.3:D / L23
1.3:D / L24
PROFIBUS
ZSS
COMMUNICATION
L1 / 1.2:B
L2 / 1.2:B
L3 / 1.2:B
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
1 3
PAN
QC3
MCB DP 2 4
6A
CONTACTOR ON
TO TRIP
1 3 5
13
Q2
3.6:A / L19
3.6:A / L20
D MPCB,3P I> I> I> 13 43 D
SPARE
READY
SPARE
14
K5 K5
2.3:B / R49_4
2.3:C / R49_3
2.4:C / R49_31
2 4 6
/2.2:A
/2.3:D 14 /2.3:D 44
1 3 5
K03
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
3.8:B / L04
1.7:C / L23
1.8:C / L24
3.7:B / L01
1.3:C / Ca_1
1.3:C / Cb_1
3.7:B / L02
3.8:B / L03
1 3 5 TO LCS /2.4:D 2 4 6
K01 AMMETER
2.4:B / R49_6
2.4:B / R49_9
/2.3:D 2 4 6 (4-20mA) X0 R1 Y1 B1
TO BRAKE DISENGAGE
& HOOTER
240VAC AUX. TO DC EM
SUPPLY
X0 R Y B BRAKE
PANEL L51 L52
3.5:A 3.6:A
U V W
E
M1
M TO HOOTER E
3~
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
PE
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D02 DOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER+BRAKE(FROM 37KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 7
13 43 21 13
L15
K01 K01A K01A K1
INTERLOCK
FUTURE
3.2:A PCS BSS
/2.3:D 14 /2.2:D 44 /2.2:D 22 /2.4:D 14
3.4:A
L16 X1 27 X1 29
X1 8
R49_4 R49_6
B B
21 1.6:D 1.6:D 95
K1 Q1
FROM UMC (TRIP 96 98
13 /2.4:D 22
CONT.)
X1 10 1.6:D
TPB 2.8:D
/2.2:E R49_9
INTERLOCK
14 L35
FUTURE
TEST
PB
YELLOW
X1 11
FROM UMC FROM UMC
TO HOOTER TO BRAKE
1.6:D 1.6:D
R49_3 R49_31
C C
R49_1 L17 L28 L18 L11 L12
1.3:B 3.5:A 1.6:B 3.6:A 1.6:B 1.6:B
13
UMC RUN ZSS
1.3:B
K01A TO LCS TRIP PCS OPERATED BSS OPERATED
/2.2:D 14 SUPPLY
R49_2 INDICATION FROM GCP FROM GCP
3.2:E 1.5:B 2.2:B
L25 L10 L35
L29
COMMON DM
3.5:A
FROM BRAKE
D RELEASE CONTACT D
3.5:A
L30
x1 x1 x1
A1 A1 A1 A1 A1
A1 H1 H2 H3
K01 -K5 -K03 -K1 RED x2 GREEN x2 AMBER x2
-K2
-K01A A2 A2 A2 A2 A2
A2
L50 / 1.8:C
READY
23
ON CONT. FWD.ON HOOTER BRAKE TRIP ON OFF TRIP TO LCS TRIP 13 14 /3.8:B
E TPB MULTI. 1 2 /1.1:D INDICATION 21 22 /3.8:C E
13 14 /2.3:C 13 14 /1.8:D 1 2 /1.7:D 13 14 /2.6:B
/2.2:B 3 4 /1.1:D 31 32 /3.8:C
24 21 22 /2.6:B 21 22 /3.7:D 3 4 /1.7:D 21 22 /2.2:B
TEST R6 03.03.2017 AS MANUFACTURED RJ43 44
KJ /3.8:C DNR
31 32 /3.8:D 5 6 /1.1:D 31 32 /3.7:D 5 6 /1.7:D 31 32 /3.7:C
PB 43 44 /2.5:B 13 14 /2.5:B 43 44 /1.8:D 43 44 /3.7:C R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
13 14 /3.8:D
53 54 /3.7:B 21 22 /3.8:D MNS DRG. NO : MNS03000220P053 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
SPARE CONTACT 63 64 /3.8:D
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D02 DOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER+BRAKE(FROM 37KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L29 / 2.2:D
L30 / 2.2:D
L19 / 1.5:D
L20 / 1.5:D
L17 / 2.5:C
L15 / 2.2:B
L16 / 2.2:B
L18 / 2.7:C
L51 / 1.8:E
L52 / 1.8:E
A 1.3:D / L05
A
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
13 30
X2 34 X2 32
25
S2 1 2
B B
LOCAL
OFF HOOTER L01 L02 L03 L04
CUM 1.3:D 1.3:D 1.4:D 1.4:D
REMOTE FLASHER
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
PCS ZSS BRAKE RELEASED
LCS CONTACTS FROM SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
STOP FIELD
BRAKE LSW
X1
16 16
LCS STOP 1.5:B / L06 X1 37 X1 39 X1 31 X1 33 X1 45
EMG
STOP x1
LCS TRIP 31 43 21 31 43
C START
LAMP
A
x2 K1 K1 K2 K2 K2 C
X1 AMBER /2.4:D 32 /2.4:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44
17 17 TRIP TRIP READY READY READY
LCS START 1.5:B / L07
X1
19 19 X1 38 X1 40 X1 32 X1 34 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49 X1 51 X1 53 X1 35 X1 43
X1
20 20
LCS EM STOP 1.6:B / L09
31 21 31 63 21 13
X1 K5 K5 K01A K01A K03 K03
23 23 /2.3:D 32 /2.3:D 22 /2.2:D 32 /2.2:D 64 /2.4:D 22 /2.4:D 14
BRAKE LSW 1.5:B / L14 HOOTER HOOTER CONT. CONT. CONT. CONT.
D
D ON ON ON ON
X1
22 22
ZSS 1.6:B / L13
X1 48 X1 50 X1 52 X1 54 X1 36 X1 44
24
X1
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D02 DOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER+BRAKE(FROM 37KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X0
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X2
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X3
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D02 DOL+CONV+PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X5
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D02 DOL+CONV
or used in any manner without the +PCS+BSS+ZSS+HOOTER+BRAKE(FROM 37KW )-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 11 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
X3 1 X3 2
1 3 5
12 14 96 98
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
/2.2:A
/2.4:B
2 4 6 QC2
L_24V / 1.3:D
L_0V / 1.2:D
MCB DP 2 4
L09 / 3.2:D
L13 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L14 / 2.8:C
L08 / 3.2:C
L28 / 2.5:C
L12 / 2.7:C
L11 / 2.7:C
AUX. TRIP 4A
CONT. CONT.
R49_2 / 2.2:D
R49_1 / 2.2:C
Cb_1 / 1.4:D
Ca_1 / 1.4:D
B B
LCS R-SELECTED
COMMON DM
LCS EM STOP
LCS START
LCS STOP
TO RUN
1.2:D / L23
1.2:D / L24
SPARE
SPARE
SPARE
PROFIBUS
ZSS
COMMUNICATION
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
TO TRIP
CONTACTOR ON
X5 X5 X1 X1 X1
101 102 51 52 53
SPARE
READY
SPARE
2.4:B / R49_6
2.4:B / R49_9
3.8:B / L04
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
3.7:B / L01
3.7:B / L02
3.8:B / L03
1.8:B / L23
1.8:B / L24
/2.3:D
1.2:B / Ca_1
1.2:B / Cb_1
2 4 6
240VAC AUX.
SUPPLY
X0 R Y B
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
PE POWER CIRCUIT MNS DRG. NO : MNS03000220P054 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D03 DOL+ZSS (UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
A X1 4
11 A
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
X1 26 X1 28 X1 35
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7 L15 13 43 21 13
3.2:A
K01 K01A K01A K1
INTERLOCK
SPARE SPARE SPARE
FUTURE
EMG /2.3:D 14 /2.2:D 44 /2.2:D 22 /2.4:D 14
STOP
3.4:A
X1 27 X1 29 X1 36
X1 8 L16
B R49_6 B
1.5:D 95
21 Q1
FROM UMC (TRIP 96 98
13 K1 CONT.)
/2.4:D 22 1.5:D
TPB
/2.2:E 14 X1 10 R49_9
TEST
2.8:D
INTERLOCK
PB FUTURE
YELLOW L35
X1 11
C C
L17 L28 L18 L11 L12 L14
3.5:A 1.6:B 3.6:A 1.6:B 1.6:B 1.5:B
ZSS
R49_1 TO LCS TRIP
SUPPLY SPARE SPARE SPARE
1.3:B INDICATION
13
UMC RUN
K01A 3.2:D 1.5:B 2.3:C
1.3:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D03 DOL+ZSS (UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L15 / 2.2:A
L17 / 2.5:C
L18 / 2.6:C
L16 / 2.2:B
A 1.3:D / L05
A
X1 12 X1 13 X1 15 X1 14 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
LCS 12 15 14 K01A
/2.2:D 54
SPARE K2
/2.8:D 14
SPARE
(TYPE-F)
25 13
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF L01 L02 L03 L04
1.3:D 1.3:D 1.3:D 1.3:D
REMOTE
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49
X1
20 20
LCS EM STOP 1.5:B / L09
31 63
K01A K01A
/2.2:D 32 /2.2:D 64
X1
22 22 CONT. CONT.
D ON ON
D
ZSS 1.6:B / L13
24 X1 48 X1 50
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D03 DOL+ZSS (UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
C -FROMFIELD 28 SPARE
C
30 SPARE TERMINAL
-FROMDCS 35 SPARE
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D03 DOL+ZSS (UPTO 36KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D03 DOL+ZSS (U
or used in any manner without the PTO 36KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FROM 240V AC
UPS SUPPLY BUS
A 415V +/-10% ,3PH , 4-WIRE , 50Hz +/-5%
R R A
Y Y X3 1 X3 2
B B
N N
1 3
QC2
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
MCB DP 2 4
4A
1 3 5
12 14 96 98
L_24V / 1.4:D
L_0V / 1.3:D
Q1 I> I> I> 11 95
L09 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L14 / 2.8:C
L08 / 3.2:C
L13 / 2.8:C
L12 / 2.7:C
L11 / 2.7:C
MCCB
/2.2:A
/2.4:B
2 4 6
B B
R49_2 / 2.2:D
R49_1 / 2.2:C
AUX. TRIP
Cb_1 / 1.5:D
Ca_1 / 1.5:D
CONT. CONT.
LCS R-SELECTED
1.3:D / L23
1.3:D / L24
COMMON DM
LCS EM STOP
LCS START
LCS STOP
TO RUN
SPARE
SPARE
SPARE
SPARE
PROFIBUS
COMMUNICATION
MOTOR ON
READY L49 L50
P1 S1 P1 S1 P1 S1 Inputs DI 230VAC DOOR DIGITAL
DIAG
CT4 FAULT
UMC 100.3 ERROR
Relay DO
230VAC/1A
DX122 DISPLAY
P2 S2 P2 S2 P2 S2
Prozessor 1 3
QC3
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3 MCB DP 2 4
6A
PAN
TO TRIP
CONTACTOR ON
13 43
K5 K5
/2.5:D 14 /2.5:D 44 D
D
3.6:A / L19
3.6:A / L20
2.4:B / R49_6
2.4:B / R49_9
2.5:B / R49_3
2.5:B / R49_4
SPARE
READY
SPARE
1 3 5
K01
3.8:B / L04
1.8:B / L23
1.8:B / L24
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
3.7:B / L01
3.7:B / L02
3.8:B / L03
1.3:B / Ca_1
1.3:B / Cb_1
/2.3:D 2 4 6
TO LCS
AMMETER HOOTER
(4-20mA)
L51 L52
3.5:A 3.5:A
240VAC AUX.
SUPPLY
X0 R Y B
TO HOOTER
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D04 DOL+HOOTER (37KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 26 X1 28 X1 35 X1 37
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7 L15 43 21 13
3.2:A
K01A K01A K1
INTERLOCK
SPARE SPARE SPARE SPARE
FUTURE
EMG /2.2:D 44 /2.2:D 22 /2.4:D 14
STOP
3.4:A
X1 27 X1 29 X1 36 X1 38
X1 8 L16
B R49_6 R49_3 B
1.6:D 95 1.7:D
21 Q1
FROM UMC (TRIP 96 98
FROM UMC
13 K1 CONT.)
/2.4:D 22 1.6:D 1.7:D
TPB
/2.2:E 14 R49_9 R49_4
TEST X1 10
PB
YELLOW INTERLOCK 2.7:D
FUTURE
L35
X1 11
C C
L18 L11 L12 L14 L13
3.6:A 1.7:B 1.6:B 1.6:B 1.7:B
TO LCS TRIP
R49_1 SPARE SPARE SPARE SPARE
1.4:B
INDICATION
13
UMC RUN K01A 3.2:D 1.5:B 2.3:C
1.4:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 -K5 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2
L50 / 1.8:C
ON CONT. FWD.ON TRIP HOOTER ON OFF TRIP TO LCS TRIP READY
MULTI. 1 2 /1.1:D 13 14 /2.6:B 13 14 /1.8:D INDICATION 13 14 /3.8:B
23
3 4 /1.2:D 21 22 /2.2:B 21 22 /3.7:D 21 22 /3.8:C
TPB 13 14 /2.3:D
31 32 /3.7:C 31 32 /3.7:D 31 32 /3.8:C
21 22 /2.6:B 5 6 /1.2:D
/2.2:B 24 43 44 /3.7:C 43 44 /1.8:D 43 44 /3.8:C
TEST 31 32 /3.8:D
E PB 43 44 /2.5:B E
53 54 /3.7:B
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
63 64 /3.8:D
SPARE CONTACT R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D04 DOL+HOOTER (37KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.6:D
L20 / 1.6:D
L51 / 1.8:D
L52 / 1.8:D
L15 / 2.2:A
L18 / 2.6:C
L16 / 2.2:B
A 1.3:D / L05
A
X1 12 X1 13 X1 57 X1 58 X1 14 X5 101 X5 102 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
101 102 13
LCS 12 57 58 14 K01A
/2.2:D 54
SPARE K2
/2.7:D 14
SPARE
(TYPE-G)
25 13
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF HOOTER L01 L02 L03 L04
CUM 1.4:D 1.4:D 1.4:D 1.4:D
REMOTE FLASHER
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
X1
19 19 X1 56 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.6:B / L08
X1 47 X1 49 X1 51 X1 53
X1
20 20
LCS EM STOP 1.6:B / L09
31 21 31 63
K5 K5 K01A K01A
/2.5:D 32 /2.5:D 22 /2.2:D 32 /2.2:D 64
HOOTER HOOTER CONT. CONT.
D ON ON
D
X1 48 X1 50 X1 52 X1 54
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D04 DOL+HOOTER (37KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
B 24 SPARE TERMINAL B
25 SPARE TERMINAL
-FROMFIELD 28 SPARE
C 30 SPARE TERMINAL
C
-FROMDCS 35 SPARE
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D04 DOL+HOOTER (37KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D04 DOL+HOOT
or used in any manner without the ER (37KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
/2.2:A
/2.4:B
2 4 6
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
AUX. TRIP 1 3
L_24V / 1.3:D
CONT. CONT.
L_0V / 1.2:D
QC2
L09 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L13 / 2.8:C
L14 / 2.7:C
L12 / 2.7:C
L11 / 2.7:C
MCB DP 2 4
4A
R49_2 / 2.2:D
R49_1 / 2.2:C
Cb_1 / 1.4:D
Ca_1 / 1.4:D
B B
LCS R-SELECTED
COMMON DM
LCS EM STOP
LCS START
LCS STOP
TO RUN
SPARE
SPARE
SPARE
SPARE
1.2:D / L23
1.2:D / L24
PROFIBUS
COMMUNICATION
Prozessor
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
CONTACTOR ON
TO TRIP
X1 X1 X1
X5 X5 51 52 53
SPARE
101 102
READY
SPARE
1 3 5
SPARE OUTPUT
K01 4-20mA OUTPUT
D /2.3:D 2 4 6 D
3.8:B / L04
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
3.7:B / L01
3.7:B / L02
3.8:B / L03
1.8:B / L23
1.8:B / L24
1.2:B / Ca_1
1.2:B / Cb_1
2.4:B / R49_6
2.4:B / R49_9
240VAC AUX.
SUPPLY
X0 R Y B
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D05 DOL (UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
A X1 4
11 A
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
X1 26 X1 28 X1 35 X1 37
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
L15 43 21 13
K01A K01A K1
INTERLOCK
3.2:A SPARE SPARE SPARE SPARE
FUTURE
/2.2:D 44 /2.2:D 22 /2.4:D 14
EMG
STOP
3.4:A X1 27 X1 29 X1 36 X1 38
X1 8
L16 R49_6
B B
1.5:D 95
Q1
21 FROM UMC (TRIP 96 98
13
K1 1.5:D
CONT.)
TPB /2.4:D 22
/2.2:E 14 R49_9
TEST
PB X1 10
YELLOW
2.7:D
INTERLOCK
FUTURE
L35
X1 11
C C
L18 L11 L12 L14 L13
3.6:A 1.6:B 1.6:B 1.5:B 1.6:B
TO LCS TRIP
R49_1 SPARE SPARE SPARE SPARE
1.3:B
INDICATION
13
UMC RUN K01A 3.2:D 1.5:B 2.3:C
1.3:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D05 DOL (UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L15 / 2.2:A
L18 / 2.6:C
L16 / 2.2:B
A 1.3:D / L05
A
X1 12 X1 13 X1 14 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
LCS 12 14 K01A
/2.2:D 54
SPARE K2
/2.7:D 14
SPARE
(TYPE-H)
25 13
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF L01 L02 L03 L04
1.3:D 1.3:D 1.3:D 1.3:D
REMOTE
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
X1
19 19 X1 32 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49
X1
20 20
LCS EM STOP 1.5:B / L09
31 63
K01A K01A
/2.2:D 32 /2.2:D 64
CONT. CONT.
D ON ON
D
X1 48 X1 50
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D05 DOL (UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
B 24 SPARE TERMINAL B
25 SPARE TERMINAL
-FROMFIELD 28 SPARE
C 30 SPARE TERMINAL
C
-FROMDCS 35 SPARE
-FROMDCS 37 SPARE
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05 DOL (UPTO 36KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05 DOL (UPTO
or used in any manner without the 36KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 3
1 3 5 QC2 X4 1 X4 2
12 14 96 98
MCB DP 2 4
4A
Q1 I> I> I> 11 95
L_24V / 1.3:D
L_0V / 1.3:D
MCCB /2.2:A
/2.4:B
L09 / 3.2:D
L10 / 2.7:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L13 / 2.8:C
L14 / 2.7:C
L12 / 2.7:C
L11 / 2.7:C
2 4 6
1 3
AUX. TRIP QC4
B MCB DP 2 4 B
R49_2 / 2.2:D
CONT. CONT.
R49_1 / 2.2:C
Cb_1 / 1.5:D
Ca_1 / 1.5:D
6A
LCS R-SELECTED
COMMON DM
LCS EM STOP
1.3:D / L23
1.3:D / L24
31
LCS START
K01A
LCS STOP
TO RUN
/2.2:D 32
SPARE
SPARE
SPARE
SPARE
PROFIBUS
COMMUNICATION
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN M1_1 M1_2
1.2:E 1.2:E
CONTACTOR ON MOTOR
SPACE HEATER
X1 X1 X1
TO TRIP
51 52 53
SPARE
READY
SPARE
SPARE OUTPUT
3.6:A / L19
3.6:A / L20
D 1 3 5
D
K01
3.8:B / L04
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
3.7:B / L01
3.7:B / L02
3.8:B / L03
1.7:B / L23
1.7:B / L24
1.3:B / Ca_1
1.3:B / Cb_1
/2.3:D 2 4 6
TO LCS
AMMETER
2.4:B / R49_6
2.4:B / R49_9
(4-20mA)
240VAC AUX.
SUPPLY
X0 R Y B
U V W M1_1 / 1.8:C
x1 HE1
E M SPACE
MOTOR E
M1 SPACE HEATER
3~ x2
HEATER
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
PE M1_2 / 1.8:C
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D05S DOL+SPH (132KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
A X1 4
11 A
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
X1 26 X1 28 X1 35 X1 37
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
L15 43 21 13
3.2:A K01A K01A K1
INTERLOCK
SPARE SPARE SPARE SPARE
FUTURE
EMG /2.2:D 44 /2.2:D 22 /2.4:D 14
STOP
3.4:A X1 27 X1 29 X1 36 X1 38
X1 8 L16 R49_6
B B
1.6:D 95
Q1
21 FROM UMC (TRIP 96 98
13 K1 CONT.)
1.6:D
TPB /2.4:D 22
/2.2:E 14 R49_9
TEST
PB X1 10
YELLOW INTERLOCK
2.7:D
FUTURE
L35
X1 11
C C
L18 L11 L12 L14 L13
3.6:A 1.6:B 1.6:B 1.5:B 1.6:B
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D05S DOL+SPH (132KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L15 / 2.2:A
L18 / 2.6:C
L16 / 2.2:B
A 1.3:D / L05
A
X1 12 X1 13 X1 14 X5 101 X5 102 X2 33 X2 31
53
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
25 13
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF L01 L02 L03 L04
1.3:D 1.3:D 1.4:D 1.4:D
REMOTE
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
X1
19 19 X1 32 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L08
X1 47 X1 49
X1
20 20
LCS EM STOP 1.6:B / L09
71 63
K01A K01A
/2.2:D 72 /2.2:D 64
CONT. CONT.
D ON ON
D
X1 48 X1 50
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103 X4 5
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D05S DOL+SPH (132KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
B 24 SPARE TERMINAL B
25 SPARE TERMINAL
-FROMFIELD 28 SPARE
C 30 SPARE TERMINAL
C
-FROMDCS 35 SPARE
-FROMDCS 37 SPARE
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X4 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
5 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X4
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D05S DOL+SPH (132KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D05S DOL+SPH (
or used in any manner without the 132KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 11 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
FROM 240V AC
UPS SUPPLY BUS
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X3 1 X3 2
1 3 5
12 14 96 98
L_24V / 1.3:D
L_0V / 1.3:D
MCCB 1 3
/2.2:A
/2.4:B
L09 / 3.1:D
L08 / 3.1:D
L10 / 2.7:D
L06 / 3.1:C
L07 / 3.1:C
L36 / 3.1:C
L14 / 2.7:C
L13 / 2.7:C
L11 / 2.7:C
2 4 6
B QC2 B
AUX. TRIP MCB DP 2 4
4A
R49_2 / 2.2:D
CONT. CONT.
R49_1 / 2.2:C
Cb_1 / 1.5:D
Ca_1 / 1.5:D
LCS R-SELECTED
COMMON DM
LCS EM STOP
LEVEL SWITCH
(LOW-LOW)
LCS START
LCS STOP
TO RUN
SPARE
SPARE
SPARE
PROFIBUS
1.3:D / L23
1.3:D / L24
COMMUNICATION
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
CONTACTOR ON
TO TRIP
X1 X1 X1
51 52 53
3.6:A / L19
3.6:A / L20
SPARE
READY
D
SPARE
D
SPARE OUTPUT
1 3 5
K01
3.8:B / L04
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
3.7:B / L01
3.7:B / L02
3.8:B / L03
1.7:C / L23
1.7:C / L24
/2.3:D TO LCS
1.3:B / Ca_1
1.3:B / Cb_1
2 4 6
AMMETER
2.4:B / R49_6
2.4:B / R49_9
(4-20mA)
240VAC AUX.
SUPPLY
X0 R Y B
U V W
E
M1
M E
3~
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
PE
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ KW)
L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
A X1 4
11 A
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
X1 26 X1 28 X1 35
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
L15 43 21 13
K01A K01A K1
INTERLOCK
3.2:A SPARE SPARE SPARE
FUTURE
/2.2:D 44 /2.2:D 22 /2.4:D 14
EMG
STOP
3.4:A X1 27 X1 29 X1 36
X1 8
L16 R49_6
B B
1.6:D 95
Q1
21 FROM UMC (TRIP 96 98
13
K1 1.6:D
CONT.)
TPB /2.4:D 22
/2.2:E 14 R49_9
TEST X1 10
PB
2.7:D
INTERLOCK
FUTURE
YELLOW
L35
X1 11
C C
L18 L11 L13 L14
3.5:A 1.6:B 1.6:B 1.5:B
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1
H1 H2 H3
-K01A K01 -K1 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ KW)
L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L15 / 2.2:A
L18 / 2.6:C
L16 / 2.2:B
A
1.3:D / L05
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 12 X1 13 X1 14 X5 101 X5 102 X2 33 X2 31
53 13
25 13 30
X2 34 X2 32
B B
S2 1 2
LOCAL
OFF L01 L02 L03 L04
1.3:D 1.3:D 1.4:D 1.4:D
REMOTE LEVEL SWITCH
A1 A2 B1 B2
(LOW-LOW) CONTACTOR
SPARE READY SPARE
ON
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46
LCS R-SELECTED 1.5:B / L36
X1 47 X1 49
X1
20 20
LCS EM STOP 1.6:B / L09
31 63
X1 K01A K01A
LEVEL SWITCH 31 31 /2.2:D 32 /2.2:D 64 D
D 1.6:B / L08 CONT. CONT.
FEED BACK ON ON
X1 48 X1 50
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
E X2 35 X3 3 X5 103
E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ KW)
L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
B 24 SPARE TERMINAL B
25 SPARE TERMINAL
-FROMFIELD 28 SPARE
C 30 SPARE TERMINAL
C
-FROMDCS 35 SPARE
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D06 DOL+PUMP+LEVEL SWITCH (FROM 37KW - 110KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D06 DOL+PUMP
or used in any manner without the +LEVEL SWITCH (FROM 37KW - 110KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
X3 1 X3 2
L_24V / 1.3:D
L_0V / 1.2:D
1 3 5
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
L09 / 3.1:D
L13 / 3.1:D
L14 / 3.1:D
L10 / 2.7:D
L06 / 3.1:C
L07 / 3.1:C
L08 / 3.1:C
L11 / 2.6:C
L12 / 2.7:C
12 14 96 98 1 3
QC2
Q1 I> I> I> 11 95 MCB DP 2 4
MCCB
/2.2:A
/2.4:B
4A
2 4 6
LCS R-SELECTED
B B
COMMON DM
LCS EM STOP
Cb_1 / 1.4:D
Ca_1 / 1.4:D
LCS START
LCS STOP
SPARE
SPARE
TO RUN
PROFIBUS
COMMUNICATION
1.2:D / L23
1.2:D / L24
R49 BUS -B1
T1 T2 Ca Cb C C DO0 DO1 DO2 0V 24VDC 1DIZ 1DI0 1DI1 1DI2 1DI3 1DI4 2DIZ 2DI5 2DI6 2DI7
READY
READY
MOTOR ON
DIAG Inputs DI 230VAC DOOR DIGITAL
FAULT
UMC 100.3 ERROR
Relay DO
230VAC/1A
DX122 DISPLAY
C Prozessor C
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
CONTACTOR ON
TO TRIP
X5 X5 X1 X1 X1
SPARE
101 102 51 52 53
READY
SPARE
1.8:B / L24
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
3.8:B / L04
3.7:B / L01
1.2:B / Ca_1
1.2:B / Cb_1
3.7:B / L02
3.8:B / L03
1 3 5 D
D
K01
/2.2:D 2 4 6
2.3:B / R49_6
2.3:B / R49_9
240VAC AUX.
SUPPLY
X0 R Y B
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
PE POWER CIRCUIT MNS DRG. NO : MNS03000220P059 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
A X1 4
11 A
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
X1 26 X1 28
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
13 21 13
K01 K01 K1
INTERLOCK
SPARE SPARE
FUTURE
L15 /2.2:D 14 /2.2:D 22 /2.3:D 14
3.2:A
EMG
X1 27 X1 29
X1 8 STOP R49_6
B 3.4:A B
1.5:D 95
L16
Q1
FROM UMC (TRIP 96 98
13 CONT.)
21 1.5:D
TPB
/2.2:E 14 K1 R49_9
TEST /2.3:D 22
PB
YELLOW
X1 10
2.7:D
INTERLOCK
FUTURE
L35
C
X1 11 C
L18 L11 L12
3.6:A 1.6:B 1.5:B
COMMON DM
D D
x1 x1 x1
A1 A1 A1
H1 H2 H3
-K01 -K1 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L18 / 2.6:C
L15 / 2.2:B
L16 / 2.2:B
A 1.3:D / L05
A
X1 12 X1 13 X1 14 X2 33 X2 31
43
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
13
LCS 12 14 K01
/2.2:D 44
SPARE K2
/2.7:D 14
SPARE
(TYPE-K)
25 13 30 40
X2 34 X2 32
S2 1 2
B B
LOCAL
OFF L01 L02 L03 L04
1.3:D 1.3:D 1.3:D 1.3:D
REMOTE
A1 A2 B1 B2
CONTACTOR
SPARE READY SPARE
ON
PX SW-1 PX SW-2
LCS
STOP
X1 SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
16 16
LCS STOP 1.5:B / L06
TRIP
x1
EMG LAMP X1 37 X1 39 X1 41 X1 43 X1 45
STOP x2
LCS AMBER
C START
C
X1 31 43 21 31 43
17 17 K1 K1 K2 K2 K2
LCS START 1.5:B / L07
/2.3:D 32 /2.3:D 44 /2.7:D 22 /2.7:D 32 /2.7:D 44
TRIP TRIP READY READY READY
X1
19 19
LCS R-SELECTED 1.5:B / L08
X1 38 X1 40 X1 42 X1 44 X1 46
X1 X1 47 X1 49
20 20
LCS EM STOP 1.5:B / L09
31 53
X1
PX SW-1( UPPER 31 31 K01 K01
1.6:B / L13 /2.2:D 32 /2.2:D 54
D CONE VALVE) D
CONT. CONT.
X1 ON ON
PX SW-2( LOWER 32 32
1.6:B / L14
CONE VALVE)
X1 48 X1 50
X1
21 21
NEUTRAL 2.6:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X2 35 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR
or used in any manner without the D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
B 24 SPARE TERMINAL B
25 SPARE TERMINAL
-FROMFIELD 28 SPARE
C 30 SPARE TERMINAL
C
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D07 DOL+DCV DPF+PX SWITCHES (0 TO 2.2KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D07 DOL+DCV D
or used in any manner without the PF+PX SWITCHES (0 TO 2.2KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 3 5
12 14 96 98 1 3
X3 1 X3 2
QC3
Q1 I> I> I> 11 95 MCB DP 2 4
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
MCCB 6A
/2.2:A
/2.5:B
2 4 6
AUX. TRIP 1 3
CONT. CONT.
QC2
MCB DP 2 4 13 43
L_24V / 1.3:D
4A
K5 K5
L_0V / 1.3:D
L09 / 3.1:D
L10 / 2.7:D
L06 / 3.1:C
L07 / 3.1:C
L08 / 3.5:A
L36 / 3.1:C
L12 / 2.8:C
L13 / 2.8:C
L11 / 2.7:C
/2.4:D 14 /2.4:D 44
B B
L1 / 1.7:C
R49_2 / 2.2:D
R49_1 / 2.2:C
L2 / 1.7:C
LCS R-SELECTED
BRAKE CONT.ON
COMMON DM
LCS EM STOP
Cb_1 / 1.5:D
Ca_1 / 1.4:D
L51 L52
LCS START
1.3:D / L23
1.3:D / L24
LCS STOP
3.5:A 3.5:A
SPARE
SPARE
SPARE
TO RUN
PROFIBUS
COMMUNICATION TO HOOTER
L1 / 1.2:B
L2 / 1.2:B
READY
READY
C P1 S1 P1 S1 P1 S1
MOTOR ON
C
DIAG Inputs DI 230VAC DOOR DIGITAL
CT4 FAULT
UMC 100.3 ERROR
Relay DO
230VAC/1A
DX122 DISPLAY
P2 S2 P2 S2 P2 S2
Prozessor
X0 R2 X0 Y2
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
1 1 DC CURRENT INJECTION BRAKE PANEL
F1 F2
2 2
TO TRIP
C2
CONTACTOR ON
11 12
L1 L2 L37 / 3.4:B
Ca
1.6:B / L23
1.7:B / L24
2.4:B / R49_3
2.4:B / R49_4
SPARE
READY
SPARE
3.6:A / L19
3.6:A / L20
(SMB)
1.3:C / Ca_1
1.3:C / Cb_1
/2.3:D 2 4 6 Cb L41 / 3.4:D D
D
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
3.8:B / L04
3.7:B / L01
2.4:B / R49_6
2.4:B / R49_9
3.7:B / L02
3.8:B / L03
240VAC AUX.
1D1
13 14 L47 / 3.5:B
SUPPLY 1 13
HOOTER C2
TO LCS 14
2
X0 R Y B AMMETER L48 / 3.5:B
(4-20mA) U V W L43 / 3.4:B
M_1 / 1.6:E
M_2 / 1.6:E A1 A1
1 3 5
C2 1D1
M_3 / 1.6:E
C2 A2 A2
2 4 6
1.2:D / M_1
X0 R1
1.2:E / M_2
E X0 Y1 E
1.2:E / M_3
U V W X0 B1
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
3~
MNS DRG. NO : MNS03000220P060 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
PE
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
POWER CIRCUIT DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D09 DOL+DC
or used in any manner without the INJECTION BRAKING+SPH+HOOTER(55KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QC1
X1 26 X1 28 X1 37
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 7
L15 11 31 43 21 13
3.2:A K01 K1 K01A K01A K1
INTERLOCK
L46 SPARE SPARE SPARE
FUTURE
EMG /2.3:D 12 /2.4:D 32 /2.2:D 44 /2.2:D 22 /2.4:D 14 3.5:A
STOP
3.4:A X1 27 X1 29 X1 38
X1 8 L16 R49_3 R49_6
B B
1.6:D 1.5:D 95
Q1
21 FROM UMC FROM UMC (TRIP 96 98 31
13 K1 CONT.) K01A
1.6:D 1.5:D
TPB /2.4:D 22 /2.2:D 32
/2.2:E 14 R49_4 R49_9
TEST
PB X1 10
YELLOW INTERLOCK
2.7:D
FUTURE
L35
X1 11
C C
L42 L26 L18 L11 L12 L13
3.4:A 3.4:A 3.5:A 1.6:B 1.6:B 1.6:B
BRAKE DC INJECTION
R49_1 ACTUATION BRAKE TO LCS TRIP
SPARE SPARE SPARE
1.3:B
COMMAND ENABLE INDICATION
13
UMC RUN
K01A 3.1:D 1.5:B 2.3:C
1.3:B /2.2:D 14 L25 L10 L35
R49_2
COMMON DM
D D
x1 x1 x1
A1 A1 A1 A1 A1
H1 H2 H3
-K01A -K01 -K5 -K1 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2
L50 / 1.7:A
ON CONT. FWD ON HOOTER TRIP ON OFF TRIP TO LCS TRIP READY
MULTI. 1 2 /1.1:D 13 14 /1.7:B 13 14 /2.6:B INDICATION 13 14 /3.8:A
23
13 14 /2.3:D 3 4 /1.1:D 21 22 /3.7:D 21 22 /2.2:B 21 22 /3.7:C
TPB 21 22 /2.6:B 31 32 /3.7:D 31 32 /2.5:B 31 32 /3.7:C
5 6 /1.1:D
/2.2:B 24 31 32 /2.5:B 11 12 /2.5:B 43 44 /1.7:B 43 44 /3.7:C 43 44 /3.8:C
TEST 43 44 /2.6:B
E PB E
53 54 /3.7:A
61 62 /3.7:D R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
SPARE CONTACT 73 74 /3.8:D
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D09 DOL+DC
or used in any manner without the INJECTION BRAKING+SPH+HOOTER(55KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1.3:D / L05
L19 / 1.5:D
L20 / 1.5:D
L15 / 2.2:A
L26 / 2.5:C
L42 / 2.5:C
L16 / 2.2:B
L08 / 1.5:B
L18 / 2.7:C
L46 / 2.7:B
L51 / 1.7:B
L52 / 1.7:B
A
X2 33 X2 31
53 13
K01A K2
/2.2:D 54
SPARE SPARE
/2.7:D 14
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 12 X1 13 X1 41 X1 42 X1 43 X1 44 X1 57 X1 58 X1 14 X5 101 X5 102
X2 34 X2 32
LCS 12 13 41 42 43 44 57 58 14 101 102
(TYPE-L)
1.8:D / L37
1.8:D / L38
1.8:D / L40
1.8:D / L43
1.8:D / L47
1.8:D / L48
LCS SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
STOP
X1
16 16
LCS STOP 1.5:B / L06 x1 X1 35 X1 59 X1 61 X1 63
TRIP
EMG LAMP
A
STOP x2
C LCS AMBER C
43 21 31 43
START
K1 K2 K2 K2
X1 /2.4:D 44 /2.7:D 22 /2.7:D 32 /2.7:D 44
17 17 TRIP READY READY READY
LCS START 1.5:B / L07
X1
19 19 X1 36 X1 60 X1 62 X1 64
LCS R-SELECTED 1.5:B / L36
X1 65 X1 67 X1 69 X1 39
X1 1.8:D
20 20 L41
LCS EM STOP 1.5:B / L09
31 21 61 73
K5 K5 K01A K01A
/2.4:D 32 /2.4:D 22 /2.2:D 62 /2.2:D 74 D
D HOOTER HOOTER CONT. CONT.
ON ON
46
X1 66 X1 68 X1 70 X1 40
X1
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 18 23 24 1 2 25 3
X1 31 32 33 34
E E
X2 35 X3 3
X5 103
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR D09 DOL+DC
or used in any manner without the INJECTION BRAKING+SPH+HOOTER(55KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
18 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
B 24 SPARE TERMINAL B
25 SPARE TERMINAL
-FROMFIELD 28 SPARE
C 30 SPARE TERMINAL
C
31 SPARE TERMINAL
32 SPARE TERMINAL
33 SPARE TERMINAL
34 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
35 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=DOL_SCHEMES+D09 DOL+DC INJECTION BRAKING+SPH+HOOTER (55KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =DOL_SCHEMES+D09 DOL+DC INJ
or used in any manner without the ECTION BRAKING+SPH+HOOTER (55KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 3 5
12 14 96 98 FROM 240V AC
UPS SUPPLY BUS
Q1
L_24V / 1.3:D
I> I> I> 11 95
L_0V / 1.2:D
MCCB
/2.2:A
/2.5:B
L10 / 2.8:D
L14 / 3.2:D
L09 / 3.2:D
L13 / 3.2:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L12 / 2.8:C
L28 / 2.6:C
L11 / 2.8:C
2 4 6
X3 1 X3 2
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
AUX. TRIP
R49_2 / 2.2:D
R49_4 / 2.3:D
CONT. CONT.
R49_1 / 2.2:C
R49_3 / 2.3:C
1 3
PCS OPERATED
BSS OPERATED
QC2
LCS R-SELECTED
LCS FWD.START
LCS REV.START
MCB DP 2 4
COMMON DM
LCS EM STOP
4A
Cb_1 / 1.4:D
Ca_1 / 1.4:D
TO FWD.RUN
TO REV.RUN
LCS STOP
B B
ZSS
PROFIBUS
COMMUNICATION
1.2:D / L23
1.2:D / L24
MOTOR ON
DIAG Inputs DI 230VAC DOOR DIGITAL
FAULT
UMC 100.3 ERROR
Relay DO
230VAC/1A
DX122 DISPLAY
Prozessor
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
C PAN C
FWD./REV.CONTACTOR ON
2.8:A 2.8:E
L49 L50
TO TRIP
X5 X5
READY
SPARE
SPARE
101 102
4-20mA OUTPUT 1 3
QC3
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
1.2:B / Ca_1
1.2:B / Cb_1
1.8:C / L23
1.8:C / L24
3.7:B / L01
3.7:B / L02
3.8:B / L04
3.8:B / L03
3.8:B / L05_1
MCB DP 2 4
6A
2.4:B / R49_6
2.4:B / R49_9
D D
2.5:B / R49_7
2.5:B / R49_8
240VAC AUX.
SUPPLY 13 43
K5 K5
/2.5:D 14 /2.5:D 44
1 3 5 1 3 5
K02 HOOTER
K01 /2.4:D
/2.3:D 2 4 6 2 4 6
L51 L52
3.5:A 3.5:A
X0 R Y B
TO HOOTER
E E
U V W R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
3~ MNS DRG. NO : MNS03000220P061 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
PE POWER CIRCUIT
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01 RDOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
QC1
FROM CONTROL BUS
A
110V AC SUPPLY
1 2
L49 / 1.7:C
X1 4
11
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 26 X1 28
13 13 43 43 21 13
L15
X1 7 3.2:A K01 K02 K01A K02A K01A K1 PCS BSS
/2.3:D 14 /2.4:D 14 /2.2:D 44 /2.3:D 44 /2.2:D 22 /2.4:D 14
EMG
INTERLOCK
FUTURE
STOP
3.4:A X1 27 X1 29
B B
L16 R49_6 R49_7
1.5:D 95 1.5:D
X1 8
Q1
21
FROM UMC (TRIP 96 98
FROM UMC
K1 CONT.)
1.5:D 1.6:D
/2.4:D 22 R49_9 R49_8
X1 10
2.8:D
INTERLOCK
L35
FUTURE
21
K02A
X1 11 /2.3:D 22
13 13
TPB2 TPB1
/2.2:E 14 /2.2:E 14
C REV FWD
C
TEST TEST L28
PB PB 1.6:B
YELLOW YELLOW
COMMON DM
D 31 31
D
K02A K01A
/2.3:D 32 /2.2:D 32
x1 x1 x1 x1
A1 A1 A1 A1 A1 A1 A1
H1F H1R H2 H3
-K01A -K02A -K01 -K02 -K1 -K5 RED x2 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2 A2 A2
L50 / 1.8:C
FWD.ON REV.ON FWD.ON REV.ON TRIP HOOTER FWD.ON REV.ON OFF TRIP TO LCS TRIP READY
CONT.MULTI. CONT.MULTI. 13 14 /2.7:B 13 14 /1.7:D INDICATION 13 14 /3.8:A
13 14 /2.3:C 13 14 /2.4:C
E 23 23 1 2 /1.1:D 1 2 /1.2:D 21 22 /2.2:B 21 22 /3.8:D 21 22 /3.7:C E
21 22 /2.6:B 21 22 /2.6:C 31 32 /3.7:C 31 32 /3.8:D 31 32 /3.8:C
3 4 /1.1:D 3 4 /1.2:D
TPB1 TPB2 31 32 /2.3:D 31 32 /2.2:D 43 44 /3.7:C 43 44 /1.8:D
43 44 /2.6:B
5 6 /1.2:D 5 6 /1.2:D R6 03.03.2017 AS MANUFACTURED RJ 43 44
KJ/3.8:C DNR
/2.2:C 24 /2.2:C 24 43 44 /2.6:B
FWD. REV 13 14 /2.5:B 13 14 /2.5:B
53 54 /3.7:A 53 54 /3.7:A R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
TEST TEST 73 74 /3.7:D 73 74 /3.7:D
PB PB 81 82 /3.8:C 81 82 /3.7:D MNS DRG. NO : MNS03000220P061 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
SPARE CONTACTS NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01 RDOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L17 / 2.5:C
L15 / 2.2:B
L16 / 2.2:B
L18 / 2.7:C
L52 / 1.8:E
L51 / 1.7:E
1.2:D / L05
A
A
X2 31 X1 23
53 53
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 13
K01A K02A K2 SPARE SPARE
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
(TYPE-N) X2 32 X1 25
25
PCS ZSS
LCS
STOP FIELD
X1 SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
16 16
LCS STOP 1.5:B / L06
TRIP
x1
EMG LAMP X1 37 X1 39 X1 41 X1 43 X1 45 X1 59
LCS STOP x2
AMBER
FWD
C START LCS C
X1 REV 31 43 21 31 43 81
17 17 START
K1 K1 K2 K2 K2 K01A
LCS FWD START 1.5:B / L07
/2.4:D 32 /2.4:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44 /2.2:D 82
X1 TRIP TRIP READY READY READY FWD..
18 18 CONT
LCS REV START 1.5:B / L08
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46 X1 60
LCS R-SELECTED 1.5:B / L14
X1
20 20 X1 61 X1 47 X1 49 X1 51 X1 53
LCS EM STOP 1.5:B / L09
73 81 73 31 21
X1
22 22 K01A K02A K02A K5 K5 D
D
ZSS 1.5:B / L13 /2.2:D 74 /2.3:D 82 /2.3:D 74 /2.5:D 32 /2.5:D 22
FWD.. REV. REV. HOOTER HOOTER
CONT CONT CONT
24
X1 X1 62 X1 48 X1 50 X1 52 X1 54
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 1 2 3
X2 33 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01 RDOL+CONV+
or used in any manner without the PCS+BSS+ZSS+HOOTER(UPTO 36KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 33 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(UPTO 36KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
A
415V +/-10% ,3PH , 4-WIRE , 50Hz +/-5%
R R
Y Y FROM 240V AC
B B UPS SUPPLY BUS
N N
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X3 1 X3 2
1 3 5
12 14 96 98 1 3
L_24V / 1.3:D
QC2
L_0V / 1.3:D
L10 / 2.8:D
L14 / 3.2:D
L09 / 3.2:D
L13 / 3.2:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L12 / 2.8:C
L28 / 2.6:C
L11 / 2.8:C
Q1 I> I> I> 11 95 MCB DP 2 4
MCCB 4A B
/2.2:A
/2.5:B
B 2 4 6
R49_2 / 2.2:D
R49_4 / 2.3:D
R49_1 / 2.2:C
R49_3 / 2.3:C
AUX. TRIP
CONT. CONT.
PCS OPERATED
BSS OPERATED
LCS R-SELECTED
LCS FWD.START
LCS REV.START
COMMON DM
LCS EM STOP
Cb_1 / 1.5:D
Ca_1 / 1.5:D
TO FWD.RUN
TO REV.RUN
LCS STOP
ZSS
1.3:D / L23
1.3:D / L24
PROFIBUS
COMMUNICATION
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
1 3
PAN
QC3
MCB DP 2 4
6A
FWD./REV.CONTACTOR ON
TO TRIP
13 43
K5 K5 D
3.6:A / L19
3.6:A / L20
D
/2.5:D 14 /2.5:D 44
READY
SPARE
SPARE
1.3:C / Ca_1
1.3:C / Cb_1
1 3 5 1 3 5 TO LCS
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
1.7:C / L23
1.7:C / L24
3.7:B / L01
3.7:B / L02
3.8:B / L04
3.7:B / L03
3.8:B / L40
K02
2.4:B / R49_6
2.4:B / R49_9
K01
2.5:B / R49_7
2.5:B / R49_8
/2.4:D AMMETER
/2.3:D 2 4 6 2 4 6
(4-20mA)
PE POWER CIRCUIT NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01 RDOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER(FROM 37KW TO 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
QC1
FROM CONTROL BUS
A
110V AC SUPPLY
1 2
L49 / 1.7:C
X1 4
11
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 26 X1 28
L15 13 13 43 43 21 13
3.2:A K01 K02 K01A K02A K01A K1
X1 7 PCS BSS
EMG /2.3:D 14 /2.4:D 14 /2.2:D 44 /2.3:D 44 /2.2:D 22 /2.4:D 14
INTERLOCK
STOP
FUTURE
3.4:A X1 27 X1 29
B L16 B
R49_6 R49_7
1.6:D 95 1.6:D
X1 8
Q1
21 FROM UMC (TRIP 96 98
FROM UMC
K1 CONT.)
/2.4:D 22 1.6:D 1.6:D
R49_9 R49_8
X1 10
INTERLOCK
FUTURE
2.8:D 21
L35 K02A
/2.3:D 22
13 13 X1 11
TPB2 TPB1
/2.2:E 14 /2.2:E 14
C REV FWD
C
TEST TEST L28
PB PB 1.6:B
YELLOW YELLOW
COMMON DM
D 31 31
D
K02A K01A
/2.3:D 32 /2.2:D 32
x1 x1 x1 x1
A1 A1 A1 A1 A1 A1 A1
H1F H1R H2 H3
-K01A -K02A -K01 -K02 -K1 -K5 RED x2 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2 A2 A2
L50 / 1.8:C
FWD.ON REV.ON FWD.ON REV.ON TRIP HOOTER FWD.ON REV.ON OFF TRIP TO LCS TRIP READY
CONT.MULTI. CONT.MULTI. 13 14 /2.7:B 13 14 /1.7:D INDICATION 13 14 /3.7:A
E 13 14 /2.3:C 13 14 /2.4:C 1 2 /1.1:D 1 2 /1.2:D 21 22 /2.2:B 21 22 /3.8:D 21 22 /3.7:C
23 23 E
21 22 /2.6:B 21 22 /2.6:C 3 4 /1.1:D 3 4 /1.2:D 31 32 /3.7:C 31 32 /3.8:D 31 32 /3.8:C
TPB1 TPB2 31 32 /2.2:D 43 44 /3.7:C 43 44 /1.8:D
31 32 /2.3:D 5 6 /1.2:D 5 6 /1.2:D R6 03.03.2017 AS MANUFACTURED RJ 43 44
KJ/3.8:C DNR
/2.2:C 24 /2.2:C 24 43 44 /2.6:B 43 44 /2.6:B
FWD. REV 13 14 /2.5:B 13 14 /2.5:B
53 54 /3.7:A 53 54 /3.7:A R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
TEST TEST
61 62 /3.8:C 61 62 /3.7:D
PB PB MNS DRG. NO : MNS03000220P062 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
73 74 /3.7:D 73 74 /3.7:D
SPARE CONTACTS NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01 RDOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER(FROM 37KW TO 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L17 / 2.5:C
L15 / 2.2:B
L16 / 2.2:B
L18 / 2.7:C
L52 / 1.8:E
L51 / 1.7:E
1.3:D / L05
A
A
X2 31 X3 31
53 53
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 X5 101 X5 102 13
K01A K02A K2
/2.2:D /2.3:D
SPARE SPARE
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
54 54 /2.8:D 14
LCS 12 13 15 57 58 14 101 102
(TYPE-O) X2 32 X3 32
25
PCS ZSS
LCS
STOP FIELD
X1 SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
16 16
LCS STOP 1.5:B / L06
TRIP
x1
EMG LAMP
A X1 37 X1 39 X1 41 X1 43 X1 45 X1 59
LCS STOP x2
AMBER
FWD
C START LCS C
X1 REV 31 43 21 31 43 61
17 17 START
K1 K1 K2 K2 K2 K01A
LCS FWD START 1.5:B / L07
/2.4:D 32 /2.4:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44 /2.2:D 62
X1 TRIP TRIP READY READY READY FWD..
18 18 CONT
LCS REV START 1.5:B / L08
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46 X1 60
LCS R-SELECTED 1.6:B / L14
X1
20 20 X1 61 X1 47 X1 49 X1 51 X1 53
LCS EM STOP 1.6:B / L09
73 61 73 31 21
X1
22 22 K01A K02A K02A K5 K5 D
D
ZSS 1.6:B / L13 /2.2:D 74 /2.3:D 62 /2.3:D 74 /2.5:D 32 /2.5:D 22
FWD.. REV. REV. HOOTER HOOTER
CONT CONT CONT
24
X1 X1 62 X1 48 X1 50 X1 52 X1 54
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 23 24 1 2 25 3
X2 33 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01 RDOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER(FROM 37KW TO 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X0
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X0DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X1DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X1DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X1DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X2
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 33 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X2DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X3
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
-FROMDCS 31 SPARE
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X3DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01 RDOL+CONV+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-X5
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01 RDOL+CON
or used in any manner without the V+PCS+BSS+ZSS+HOOTER(FROM 37KW TO 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X5DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
A
415V +/-10% ,3PH , 4-WIRE , 50Hz +/-5%
R R
Y Y FROM 240V AC
B B UPS SUPPLY BUS FROM 240V ACAC,SPACE
N N HEATER AND AUX.CKT BUS
L
PH PH
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X3 1 X3 2
N
N N
1 3 5
12 14 96 98 1 3
L_24V / 1.3:D
QC2
L_0V / 1.3:D
L10 / 2.8:D
L14 / 3.2:D
L09 / 3.2:D
L13 / 3.2:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L12 / 2.8:C
L28 / 2.6:C
L11 / 2.8:C
Q1 I> I> I> 11 95 MCB DP 2 4
MCCB 4A X4 1 X4 2
B
/2.2:A
/2.5:B
B 2 4 6
R49_2 / 2.2:D
R49_4 / 2.3:D
R49_1 / 2.2:C
R49_3 / 2.3:C
AUX. TRIP
CONT. CONT.
1 3
PCS OPERATED
BSS OPERATED
QC4
LCS R-SELECTED
LCS FWD.START
MCB DP
LCS REV.START
2 4
COMMON DM
LCS EM STOP
6A
Cb_1 / 1.5:D
Ca_1 / 1.5:D
TO FWD.RUN
TO REV.RUN
LCS STOP
ZSS
61
/ L23-1
/ L24-1
1.3:D / L23
1.3:D / L24
PROFIBUS K01A
COMMUNICATION /2.2:D 62
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
1 3
PAN
QC3
MCB DP 2 4 M1_1 M1_2
6A 1.2:E 1.2:E
FWD./REV.CONTACTOR ON
MOTOR
TO TRIP
SPACE HEATER
13 43
K5 K5 D
3.6:A / L19
3.6:A / L20
D
/2.5:D 14 /2.5:D 44
READY
SPARE
SPARE
1.3:C / Ca_1
1.3:C / Cb_1
TO LCS
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
1.7:C / L23
1.7:C / L24
3.7:B / L01
3.7:B / L02
3.8:B / L04
3.7:B / L03
3.8:B / L40
2.4:B / R49_6
2.4:B / R49_9
2.5:B / R49_7
2.5:B / R49_8
1 3 5 1 3 5
K02 AMMETER
K01 /2.4:D (4-20mA)
/2.3:D 2 4 6 2 4 6
PE M1_2 / 1.8:C NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
POWER CIRCUIT DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01S RDOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER(ABOVE 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
QC1
FROM CONTROL BUS
A
110V AC SUPPLY
1 2
L49 / 1.7:C
X1 4
11
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 26 X1 28
13 13 43 43 21 13
L15
X1 7 3.2:A K01 K02 K01A K02A K01A K1 PCS BSS
/2.3:D 14 /2.4:D 14 /2.2:D 44 /2.3:D 44 /2.2:D 22 /2.4:D 14
EMG
INTERLOCK
FUTURE
STOP
3.4:A X1 27 X1 29
B B
L16 R49_6 R49_7
1.6:D 95 1.6:D
X1 8
Q1
21
FROM UMC (TRIP 96 98
FROM UMC
K1 CONT.)
1.6:D 1.6:D
/2.4:D 22 R49_9 R49_8
X1 10
INTERLOCK
FUTURE
21
2.8:D
K02A
L35
X1 11 /2.3:D 22
13 13
TPB2 TPB1
/2.2:E 14 /2.2:E 14
C REV FWD L28 C
TEST TEST 1.6:B
PB PB
YELLOW YELLOW
COMMON DM
D 31 31
D
K02A K01A
/2.3:D 32 /2.2:D 32
x1 x1 x1 x1
A1 A1 A1 A1 A1 A1 A1
H1F H1R H2 H3
-K01A -K02A -K01 -K02 -K1 -K5 RED x2 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2 A2 A2
L50 / 1.8:C
FWD.ON REV.ON FWD.ON REV.ON TRIP HOOTER FWD.ON REV.ON OFF TRIP TO LCS TRIP READY
CONT.MULTI. CONT.MULTI. 13 14 /2.7:B 13 14 /1.7:D INDICATION 13 14 /3.7:A
E 13 14 /2.3:C 13 14 /2.4:C 1 2 /1.1:D 1 2 /1.2:D 21 22 /2.2:B 21 22 /3.8:D 21 22 /3.7:C
23 23 E
21 22 /2.6:B 21 22 /2.6:C 3 4 /1.1:D 3 4 /1.2:D 31 32 /3.7:C 31 32 /3.8:D 31 32 /3.8:C
TPB1 TPB2 31 32 /2.3:D 43 44 /3.7:C 43 44 /1.8:D
31 32 /2.2:D 5 6 /1.2:D 5 6 /1.2:D R6 03.03.2017 AS MANUFACTURED RJ 43 44
KJ/3.8:C DNR
/2.2:C 24 /2.2:C 24 43 44 /2.6:B 43 44 /2.6:B 13 14 /2.5:B 13 14 /2.5:B
FWD. REV 53 54 /3.7:A R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
53 54 /3.7:A
TEST TEST 61 62 /1.8:C
PB PB 61 62 /1.8:C
73 74 /3.7:D 73 74 /3.7:D MNS DRG. NO : MNS03000220P062A R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
SPARE CONTACTS 81 82 /3.8:C 81 82 /3.7:D NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01S RDOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER(ABOVE 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L17 / 2.5:C
L15 / 2.2:B
L16 / 2.2:B
L18 / 2.7:C
L52 / 1.8:E
L51 / 1.7:E
1.3:D / L05
A
A
X2 31 X3 31
53 53
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 X5 101 X5 102 13
K01A K02A K2 SPARE SPARE
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
(TYPE-O) X2 32 X3 32
25
PCS ZSS
LCS
STOP FIELD
X1 SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
16 16
LCS STOP 1.5:B / L06
TRIP
x1
EMG LAMP
A X1 37 X1 39 X1 41 X1 43 X1 45 X1 59
LCS STOP x2
AMBER
FWD
C START LCS C
X1 REV 31 43 21 31 43 81
17 17 START
K1 K1 K2 K2 K2 K01A
LCS FWD START 1.5:B / L07
/2.4:D 32 /2.4:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44 /2.2:D 82
X1 TRIP TRIP READY READY READY FWD..
18 18 CONT
LCS REV START 1.5:B / L08
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46 X1 60
LCS R-SELECTED 1.6:B / L14
X1
20 20 X1 61 X1 47 X1 49 X1 51 X1 53
LCS EM STOP 1.6:B / L09
73 81 73 31 21
X1
22 22 K01A K02A K02A K5 K5 D
D
ZSS 1.6:B / L13 /2.2:D 74 /2.3:D 82 /2.3:D 74 /2.5:D 32 /2.5:D 22
FWD.. REV. REV. HOOTER HOOTER
CONT CONT CONT
24
X1 X1 62 X1 48 X1 50 X1 52 X1 54
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 23 24 1 2 25 3
X2 33 X3 3 X4 5 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R01S RDOL+CONV+PCS+
or used in any manner without the BSS+ZSS+HOOTER(ABOVE 110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X0
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X0DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X1DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X1DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X1
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X1DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X2
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 33 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X2DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X3
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X3DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X4
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
5 SPARE TERMINAL
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X4DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R01S RDOL+CONV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-X5
To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R01S RDOL+CO
or used in any manner without the NV+PCS+BSS+ZSS+HOOTER+SPH(ABOVE 110KW)-
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ X5DRG.No. O12247-0GS-E-V-2200-003
L&T SHT. 11 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 11 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
A
415V +/-10% ,3PH , 4-WIRE , 50Hz +/-5%
R R
Y Y
B B
N N FROM 240V AC
UPS SUPPLY BUS
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 3 5
12 14 96 98
X3 1 X3 2
/2.2:A
/2.5:B
2 4 6
AUX. TRIP 1 3
L_24V / 1.3:D
CONT. CONT.
QC2
L_0V / 1.3:D
B B
L10 / 2.8:D
L14 / 3.2:D
L09 / 3.2:D
L13 / 3.2:D
L06 / 3.2:C
L07 / 3.2:C
L08 / 3.2:C
L12 / 2.8:C
L28 / 2.6:C
L11 / 2.8:C
MCB DP 2 4
4A
R49_2 / 2.2:D
R49_4 / 2.3:D
R49_1 / 2.2:C
R49_3 / 2.3:C
LCS R-SELECTED
LCS FWD.START
LCS REV.START
COMMON DM
LCS EM STOP
Cb_1 / 1.5:D
Ca_1 / 1.5:D
TO FWD.RUN
TO REV.RUN
LCS STOP
SPARE
SPARE
PROFIBUS
ZSS
1.3:D / L23
1.3:D / L24
COMMUNICATION
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3 1 3
PAN QC3
MCB DP 2 4
6A
FWD./REV.CONTACTOR ON
TO TRIP
13 43
D K5 K5 D
/2.4:D 14 /2.4:D 44
READY
SPARE
SPARE
3.6:A / L19
3.6:A / L20
1.3:C / Ca_1
1.3:C / Cb_1
1.5:B / L_0V
3.7:A / L05
1.5:B / L_24V
1.7:C / L23
1.7:C / L24
3.7:B / L01
3.7:B / L02
3.8:B / L04
3.8:B / L03
3.8:B / L40
2.5:B / R49_6
2.5:B / R49_9
1 3 5 1 3 5
2.4:B / R49_7
2.4:B / R49_8
K02 TO LCS
K01
/2.3:D 2 4 6 2 4 6
/2.4:D AMMETER
(4-20mA) L51 L52
240VAC AUX. 3.5:A 3.5:A
SUPPLY
HOOTER TO HOOTER
X0 R Y B
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
U V W
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
M1
M
3~ MNS DRG. NO : MNS03000220P063 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
PE NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
POWER CIRCUIT DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R07 RDOL+STAR
or used in any manner without the CRUSHER+ZSS+HOOTER(110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 1 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
QC1
FROM CONTROL BUS
A
110V AC SUPPLY
1 2
L49 / 1.7:C
X1 4
11
Q1
3 4 (AUX. 12 14
CONT.)
X1 5
6A,DP
MCB
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
X1 26 X1 28
13 13 43 43 21 13
L15
X1 7 3.2:A K01 K02 K01A K02A K01A K1 SPARE SPARE
/2.3:D 14 /2.4:D 14 /2.2:D 44 /2.3:D 44 /2.2:D 22 /2.5:D 14
EMG
INTERLOCK
FUTURE
STOP
3.4:A X1 27 X1 29
B B
L16 R49_7 R49_6
1.6:D 1.6:D 95
X1 8
Q1
21
FROM UMC FROM UMC (TRIP 96 98
K1 CONT.)
1.6:D 1.6:D
/2.5:D 22 R49_8 R49_9
X1 10
INTERLOCK
FUTURE
2.8:D 21
L35 K02A
X1 11 /2.3:D 22
13 13
TPB2 TPB1
/2.2:E 14 /2.2:E 14
C REV FWD L28
TEST TEST 1.6:B C
PB PB
YELLOW YELLOW
COMMON DM
D 31 31
D
K02A K01A
/2.3:D 32 /2.2:D 32
x1 x1 x1 x1
A1 A1 A1 A1 A1 A1 A1
H1F H1R H2 H3
-K01A -K02A K01 -K02 -K5 -K1 RED x2 RED x2 GREEN x2 AMBER x2
-K2
A2 A2 A2 A2 A2 A2 A2
L50 / 1.8:C
FWD.ON REV.ON FWD.ON REV.ON
HOOTER TRIP FWD.ON REV.ON OFF TRIP TO LCS TRIP READY
CONT.MULTI. CONT.MULTI.
13 14 /2.3:C 13 14 /2.4:C 13 14 /1.7:D 13 14 /2.7:B INDICATION 13 14 /3.8:A
E 23 23 21 22 /2.7:B 21 22 /2.7:C 1 2 /1.1:D 1 2 /1.2:D 21 22 /3.8:D 21 22 /2.2:B 21 22 /3.7:C E
31 32 /2.3:D 31 32 /2.2:D 3 4 /1.1:D 3 4 /1.2:D 31 32 /3.8:D 31 32 /3.7:C 31 32 /3.8:C
TPB1 TPB2 43 44 /2.6:B 43 44 /2.6:B 43 44 /1.8:D 43 44 /3.7:C
5 6 /1.2:D 5 6 /1.2:D R6 03.03.2017 AS MANUFACTURED RJ 43 44
KJ/3.8:C DNR
/2.2:C 24 /2.2:C 24 53 54 /3.7:A 53 54 /3.7:A
FWD. REV 13 14 /2.5:B 13 14 /2.6:B
73 74 /3.7:D 73 74 /3.7:D R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
TEST TEST
PB PB 81 82 /3.8:C 81 82 /3.7:D
MNS DRG. NO : MNS03000220P063 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
SPARE CONTACTS NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R07 RDOL+STAR
or used in any manner without the CRUSHER+ZSS+HOOTER(110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 2 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L19 / 1.5:D
L20 / 1.5:D
L17 / 2.5:C
L15 / 2.2:B
L16 / 2.2:B
L18 / 2.7:C
L52 / 1.8:E
L51 / 1.7:E
1.3:D / L05
A
A
X2 31 X3 31
53 53
X1 12 X1 13 X1 15 X1 57 X1 58 X1 14 X5 101 X5 102 13
K01A K02A K2 SPARE SPARE
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
(TYPE-P) X2 32 X3 32
25 13
ZSS
LCS
STOP
X1 SPARE CONTACTOR TO BE WIRED UPTO TERMINAL
16 16
LCS STOP 1.5:B / L06
TRIP
x1
EMG LAMP
A X1 37 X1 39 X1 41 X1 43 X1 45 X1 59
LCS STOP x2
AMBER
FWD
C START LCS C
X1 REV 31 43 21 31 43 81
17 17 START
K1 K1 K2 K2 K2 K01A
LCS FWD START 1.5:B / L07
/2.5:D 32 /2.5:D 44 /2.8:D 22 /2.8:D 32 /2.8:D 44 /2.2:D 82
X1 TRIP TRIP READY READY READY FWD..
18 18 CONT
LCS REV START 1.5:B / L08
X1
19 19 X1 38 X1 40 X1 42 X1 44 X1 46 X1 60
LCS R-SELECTED 1.6:B / L14
X1
20 20 X1 61 X1 47 X1 49 X1 51 X1 53
LCS EM STOP 1.6:B / L09
73 81 73 31 21
X1
22 22 K01A K02A K02A K5 K5 D
D
ZSS 1.6:B / L13 /2.2:D 74 /2.3:D 82 /2.3:D 74 /2.4:D 32 /2.4:D 22
FWD.. REV. REV. HOOTER HOOTER
CONT CONT CONT
24
X1 X1 62 X1 48 X1 50 X1 52 X1 54
21 21
NEUTRAL 2.7:D / L25
SPARE TERMINALS
X1 30 6 9 23 24 1 2 25 3
X2 33 X3 3 X5 103
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ CONTROL SCHEMES FOR R07 RDOL+STAR
or used in any manner without the CRUSHER+ZSS+HOOTER(110KW)
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 3 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X0 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X0
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 4 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
1 SPARE TERMINAL
2 SPARE TERMINAL
B 3 SPARE TERMINAL B
6 SPARE TERMINAL
C 9 SPARE TERMINAL
C
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 5 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
23 SPARE TERMINAL
24 SPARE TERMINAL
25 SPARE TERMINAL
30 SPARE TERMINAL
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 6 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X1 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X1
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 7 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X2 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 33 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X2
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 8 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X3 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
B 3 SPARE TERMINAL B
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X3
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 9 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Terminal diagram
A
A
Strip
=RDOL_SCHEMES+R07 RDOL+STAR CRUSHER+ZSS+HOOTER(110KW)-X5 To
From
Target designation wiring jumper function text jumper wiring Target designation Placement
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
C C
D D
E E
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
DEC DRG. NO : 3BYN424017-CDA REV DATE REVISION COMMENTS DRN CKD APD
They shall not be disclosed, reproduced CIVIL & STRUCTURAL DRN KK KJ Terminal diagram =RDOL_SCHEMES+R07 RDOL+STA
or used in any manner without the R CRUSHER+ZSS+HOOTER(110KW)-X5
ELECTRICAL CKD KJ KJ
prior written consent of ABB India Ltd.
- INSTRUMENTATION APD DNR KJ L&T DRG.No. O12247-0GS-E-V-2200-003 SHT. 10 REV.
Sr.No REFERENCE DRAWING DRAWING NO: MECHANICAL JSPL DRG.No. ANG2-05-E-18-2200 TOTAL SHT: 10 R6
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
L_24V / 1.3:C
MCCB
/2.2:A
/2.5:B
L_0V / 1.2:C
2 4 6
L12 / 3.1:D
L13 / 3.1:D
L14 / 3.1:D
L10 / 2.7:D
L06 / 3.1:C
L07 / 3.1:C
L08 / 3.1:C
L11 / 3.1:C
L09 / 3.1:C
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Industry Pvt. Ltd
AUX. TRIP 1 3
R49_1 / 2.2:C
R49_3 / 2.3:C
R49_2 / 2.2:C
R49_4 / 2.3:C
CONT. CONT.
QC2
MCB DP 2 4
4A
LCS R-SELECTED
LCS FWD.START
LCS REV.START
LCS EM STOP
COMMON DM
TO FWD.RUN
TO REV.RUN
LCS STOP
B
Cb_1 / 1.4:D
Ca_1 / 1.4:D
B
ELS(R)
TLS(R)
ELS(L)
PROFIBUS
COMMUNICATION
1.2:C / L23
1.2:C / L24
R49 BUS -B1
T1 T2 Ca Cb C C DO0 DO1 DO2 0V 24VDC 1DIZ 1DI0 1DI1 1DI2 1DI3 1DI4 2DIZ 2DI5 2DI6 2DI7
READY
READY
MOTOR ON
DIAG Inputs DI 230VAC DOOR DIGITAL
FAULT
UMC 100.3 ERROR
Relay DO
230VAC/1A
DX122 DISPLAY
Prozessor
C C
0V 240VAC 0V 24V DC DO3 DI0 DI1 DI2 DI3 DI4 DI5 1Ca 2Ca 1Cb 2Cb AO+ AO- 1DOC 1DO0 1DO1 2DOC 2DO2 2DO3
PAN
FWD./REV.CONTACTOR ON
X1 X1 X1
1.4:B / L_0V
3.7:A / L05
1.4:B / L_24V
TO TRIP
1.8:B / L23
1.8:B / L24
SPARE
SPARE 63 64 65
READY
X5 X5
TLS(L)
101 102
SPARE OUTPUT
4-20mA OUTPUT
1.2:B / Ca_1
1.2:B / Cb_1
3.7:B / L01
3.7:B / L02
3.8:B / L40
3.7:B / L03
3.8:B / L04
3.8:B / L41
240VAC AUX.
SUPPLY
D D
2.4:B / R49_6
2.4:B / R49_9
1 3 5 1 3 5
K02
K01 /2.4:D
/2.3:D 2 4 6 2 4 6
X0 R Y B
E E
U V W
R6 03.03.2017 AS MANUFACTURED RJ KJ DNR
M1
M
3~ R5 28.11.2016 INTERNAL CHANGES RJ KJ DNR
PE POWER CIRCUIT MNS DRG. NO : MNS03000220P064 R4 08.06.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR
NAME SIGN DATE DEC NAME : ABB INDIA LTD. R3 23.01.2016 AS PER CUSTOMER COMMENTS RJ KJ DNR