You are on page 1of 6

ETAP is the most comprehensive analysis platform for the

design, simulation, operation, and automation of generation,


distribution, and industrial power systems. ETAP is developed
under an established quality assurance program and is used
worldwide as a high impact software.

As a fully integrated enterprise solution, ETAP extends to a


Real-Time Intelligent Power Management System to monitor,
control, automate, simulate, and optimize the operation
of power systems.

Operation Technology, Inc.


(800) 477-ETAP (949) 900-1000
Base Package
ETAP Base Package is a set of core tools, embedded analysis modules, and engineering libraries that allow you to create,
configure, customize, and manage your system model. Core tools allow you to quickly and easily build 3-phase and 1-phase
AC and DC network one-line diagrams with unlimited buses and elements including detailed instrumentation and grounding
components. Base Package includes an intelligent one-line diagram, element editors, configuration manager, report manager,
project and study wizards, multi-dimensional database, theme manager, data exchange, and user access management.
Embedded analysis modules such as Cable Ampacity, Cable Sizing, and Transmission Line Constants provide integrated as well
as stand-alone capabilities to design, analyze, and size equipment. Engineering libraries provide complete verified and validated
data based on equipment manufacturers published data.

System Elements Multi-Dimensional Database


Embedded Analysis Modules Unlimited AC (1-phase & 3-phase) & DC elements Orthogonal multi-dimension database
Unlimited buses: license dependent at run-time Unlimited independent graphical views
- Cable Ampacity Nested views (composite networks & MCC) Unlimited status configurations
Power grids, synchronous, & induction generators Unlimited property revisions
MOV, synchronous, & induction motors Multiple loading & generation conditions
- Cable Sizing
Exciters, governors, & stabilizers Real-time operating data
Voltage & frequency dependent lumped loads Unlimited study solutions
- Transmission Line Constants Cables, lines, reactors, & impedance branches ODBC MS Access, SQL server, & Oracle
2W & 3W transformers with voltage regulators Dumpster with unlimited cells: copy & paste
Remote connectors User access security with password protection
Harmonic filters & static var compensator Edited-by & checked-by with date stamping
Instrument transformers Merge project files via clipboard
Protective devices & meters
Single & double throw switches
Batteries, DC motors, loads, & branches
Chargers, inverters, UPS, & DC converters
ANSI, IEC, & user-defined elements with rotation
& multiple sizes

Libraries
Comprehensive library: ANSI & IEC devices
Verified & Validated (V&V) library data
One-Line Diagram V&V locked data
Built-in intelligent graphics Add, copy, merge, & delete capabilities
Network nesting User-defined & controlled libraries
Integrated 1-Phase, 3-Phase, & DC systems User-access control & security
Integrated AC, DC, & grounding systems Edited-by & checked-by with date stamping
Multiple generators & grid connections User-controlled library merge
Display results on one-line diagrams
Cable LV Circuit Breaker
Customizable font types, styles, & colors
Customizable display of ratings & results Cable Fire Protection Solid State Trip
Graphical display of equipment grounding Transmission Line Thermal Magnetic
Output Report Comparator
ETAP provides a time-saving capability to
Graphical display of overstressed devices & alerts Motor Nameplate Electro-Magnetic automatically run multiple scenarios with
Hide & show protective devices & grounding systems
Motor CKT Model Motor Circuit Protector different project files and verify their study results
Theme manager with status & kV color control
(load flow, short circuit, etc.) against benchmark
One-line templates Motor Characteristics Model Overload Heater reports (results obtained previously). Once set
Propagation of nominal & rated voltage Motor Load Model Harmonic up, you can compare hundreds of study reports
Propagation of phase connection together with one action. This is also a great
Fuse Interruption Cost
Automatic display of energized & de-energized tool for the internal verification and validation of
elements using dynamic continuity check Relay Reliability a new version of ETAP after initial installation,
Text box editor with dynamic link to properties Recloser Battery i.e., study results from the latest version of ETAP
OLE object & ActiveX control integration are automatically compared with results of older
Electronic Controller Control Contact / Relay
Intelligent text box & hyperlink bookmarks releases of ETAP with Pass/Fail flags.
Customizable output reports via Crystal Reports HV Circuit Breaker Solenoid
Batch printing with view-dependent printer settings Network Simulation
User-friendly plotting Unlimited buses (license dependent) & elements
Project Management Wizards Looped & radial systems
Manage studies with scenarios & macros Automatic error checking
Record scenarios based on study settings User interface for all network analysis modules
Macro controlled scenario execution Customizable ETAP preference properties
Multi-level user access management

Built-In Calculators
MVA, MW, Mvar, kV, Amp, & PF conversion
Motor nameplate & dynamic parameter data
Generation nameplate
Power grid short circuit impedances
Motor & generation inertia

Report Manager Data Exchange


Customizable output reports & plots Configuration Manager WMF / EMF / DXF / PDF exporting
Input, results, alerts, & summary reports Tabulate & control different status configurations Import RAW / IEEE / CSV files
Reports via Crystal Reports viewer Compare source, load, & switching device status Export one-line diagrams in DXF format
PDF, MS Word, Access, & Excel reports Flag changed data with checker capability Import ground grid plans from AutoCAD
Element ID & text search capability Copy, merge, export, import, & print
Modular

Network Analysis Protective Devices Dynamics & Transients


Short Circuit - ANSI / IEEE Coordination & Selectivity Transient Stability
ANSI / IEEE C37 Standards AC & DC coordination Complete synchronous & induction machine models
IEEE 141 & 399 Standards Graphically adjustable device settings Comprehensive excitation system models
UL 489 Standard Extensive device library (verified & validated) Comprehensive governor-turbine models
Integrates with protective device coordination Embedded short circuit analysis Power System Stabilizer (PSS) models
Automatic device evaluation for 3-phase, 1-phase, Embedded motor acceleration analysis GE, Westinghouse, & solar gas turbines
& panel systems Integrated with one-line diagram User-Defined Dynamic Models (UDM)
Generator CB evaluation Multi-axis time current curves Unlimited sequence of events & actions
Phase-shifting transformer Comprehensive plot options Typical & common disturbances & operations
Load terminal short circuit calculation Adjustable magnifying-glass zoom view Automatic actions based on relay settings
Time difference calculator Short-time & long-time simulation
Short Circuit - IEC Multi-function/level relays Variable total simulation time & simulation step
IEC 60909, 60282, 60781, & 60947 Standards Device setting reports 3-phase & line-to-ground fault actions
Transient fault analysis - IEC 61363 Standard Auto-sync check action
Integrates with protective device coordination Sequence-of-Operation Embedded Newton-Raphson initial load flow
Automatic device evaluation for 3-phase, 1-phase, View device operation sequence graphically
& panel systems Device failure & backup operation Generator Start-Up
User-definable voltage c factor Sequence viewer Cold-state generator starting
Load terminal short circuit calculation Normalized (shifted) curves Load generators prior to synchronous speed
Current summation Frequency-dependent machine models
Arc Flash Relay actions (27, 49, 50, 51, 51V, 59, 67, 79, 87) Frequency-dependent network models
IEEE 1584a 2004 Standard An expansion to the Transient Stability module
IEEE 1584 2002 Standard Relay Test Set Interface Utilizes user-defined dynamic models
NFPA 70E 2000, 2004, & 2009 Standards Export short circuit data relays settings
CSA Z462 2008 Standard Plot device steady-state response Wind Turbine Generator
ASTM D 120-02a Standard Compare relay response with manufacturer Model unlimited wind turbine generators
OSHA 29 CFR 1910 Standard published data Detailed modeling of turbine dynamics,
NEC 110.6 Standard Display relay actual transient response aerodynamics, & power coefficients
NESC Standard Analyze relay false trips & mis-operation DFIG with pitch & converter controller
Embedded short circuit calculation Simulate wind disturbance like ramp & gust
Embedded device coordination Individual or zone-based disturbances
Cubic box & open air
Report & label generation User-Defined Dynamic Model
Maintenance mode switch Library of pre-built models
Relay actions (49, 50, 51, 67, 79, 87) Customize existing UDM models
Load terminal faults Wide variety of blocks for building models
Panels & single-phase systems Import Simulink models
Multi-report result analyzer Various model testing methods
Work permits & data sheets Real-time compiling & linking of model

Load Flow Parameter Estimation


Power flow Relay Testing & Simulation Induction machine equivalent circuits
Demand load Single-cage models
Voltage drop Relay Test Set Equipment Rotor deep-bar effects
Power factor correction Test, simulate, & calibrate relays, meters,
Automatic device evaluation & transducers
Automatic temperature correction Test 24 different IEEE type relays
2W & 3W transformer LTC/regulator actions Powerful & lightweight
Real & reactive power losses High accuracy & self-calibrating Explore ETAP with a
Multiple current & voltage outputs
Extensive violation alerts
Multi-report result analyzer Auxiliary DC supply Free Demo at etap.com
Motor Acceleration ETAP Test Set Software
Dynamic motor acceleration Manual & fully automatic testing
Voltage flicker View control panel & vector quantities
Motor & load dynamic models Click & Test feature for quick testing
Static motor starting Playback transients from ETAP fault studies
Multi-sequence starting Playback transients from fault recorders
Conventional & soft starting devices Export to Comtrade format
Load & generation transitioning
Motor Operated Valve (MOV) simulation
Comprehensive alarm & warning
Intuitive

Cable Systems Distribution Systems Transmission Line


Underground Thermal Analysis Unbalanced Load Flow Line Constants
Neher-McGrath Method Unbalanced power flow Conductor & ground wire libraries
IEC 60287 Standard Single-phase & unbalanced 3-phase modeling Built-in configurations: horizontal, vertical, etc.
Steady-state temperature Unbalanced & nonlinear load modeling General configuration: X, Y, & Z coordinates
Ampacity optimization Phase & sequence voltage, current, & power Multi-line mutual coupling
Automatic cable sizing Voltage & current unbalance factors Phase & sequence impedance matrix
Transient temperature Transmission line coupling Transposed & un-transposed lines
Automatic device evaluation Short & long line models
Cable Pulling Multiple layer soil model
Integrated with one-line diagram cables Optimal Power Flow Calculated or user-defined impedances
Integrated with underground raceways cables Solve multiple objectives simultaneously
Pull multiple cables Interior point method with barrier functions Line Ampacity
Completely flexible pull geometry Minimize power losses Conductor ampacity vs. temperature
Full ETAP cable library integration Active power optimization IEEE 738 1993 Standard
Display 3-D pulling path geometry Reactive power optimization Determine maximum operating temperature for
Optimal dispatch various loading conditions
Cable Ampacity Calculate derated ampacity based on temperature
ICEA P-54-440 Standard Optimal Capacitor Placement limit
National Electrical Code NFPA 70 Optimal location & bank size Consider weather, solar heat, & geographical location
IEEE 399 Standard Minimize installation & operation costs
British 7671 Standard Individual source or average energy cost Sag & Tension
Installation types include: Voltage and/or power factor objectives Sag/tension vs. temperature
-- U/G duct banks - Trenches Minimum, maximum, & average loading Multiple spans between dead-end structures
-- U/G direct buried - Brackets Branch capacity release & cost savings Level spans of unequal length
-- Trays - Cleats Review capacitor impact on the system Solve spans of unequal length on different horizontal
-- Ladders - Building voids Capacitor control method planes
-- A/G conduit - Trunking Flexible constraints Include effects of wind, temperature, & k factor
-- Air drops - Embedded direct
Reliability Assessment HVDC Transmission Link
Cable Sizing System reliability Detailed rectifier & converter modeling
Ampacity, voltage drop, & short circuit options Customer oriented indices Composite AC/DC & DC/AC systems
Optimal & alternative sizes Energy (cost) indices Built-in control schemes
Size based on actual loading and/or ratings Sensitivity analysis Inclusive transformer model
Single & double contingency Automatic harmonic spectrum calculation
Easy-to-use integrated model
Single-Phase Distribution
ANSI & IEC Standards
Load flow with graphical per phase display
Voltage drop & power losses
Voltage & current unbalance factors
Automatic device duty evaluation & alerts

Ground Grid Systems Transformer


Finite Element Method MVA Sizing
3-D plots for step, touch, & absolute potentials Sizing based on actual connected or operating load
3-D irregular configurations ANSI & IEC standard types, classes, & ratings
3-D graphical interface views Considers ambient temperature, altitude, load
Rods & conductors in any direction Geographic Information System growth, & load factors
Graphical display of over limits
(see DataX - CAD interface) GIS Map Tap Optimization
View GIS maps in ETAP ANSI/IEEE C57.116 Standard
IEEE 80 & 665 Standards Display analysis results on GIS maps Optimize unit transformer turns ratio
Conductor & rod optimization Synchronize GIS data to ETAP projects Considers system voltage variation
3-D graphical interface views Use graphical user interface for data mapping Considers generation station auxiliary load
Control modification & accept/reject actions Generator reactive capacity vs. voltage plots
Check consistency for data synchronization
Utilize GIS map tools
Integrated

DC Systems Power Quality Data Exchange


Load Flow Harmonic Load Flow DataX
IEEE 946 Standard IEEE 519 Standard Import & export data
Integrated AC & DC systems Automatic distortion evaluation (THD & IHD) Data synchronization
Embedded Newton-Raphson Method Telephone influence factors (TIF & I*T) Automatic one-line diagram generation
Voltage drop Automatic alerts of violations Intelligent error checking
Power losses Harmonic sources library Customizable data mapping
Battery auto-activation Embedded Newton-Raphson Method Real-time data exchange
Charger/UPS current limit Embedded Accelerated Gauss-Seidel Method RAW data IEEE format
Charger/UPS mode auto-switching
DC converter modeling Frequency Scan SmartPlant Electrical Interface
Motor model auto-switching User-definable frequency range Bi-directional data exchange
Identify resonance conditions Map attributes of SPEL with ETAP elements
Short Circuit User-customizable plots Automatic one-line diagram generation
IEEE 946 Standard Synchronize SPEL data with ETAP projects
Integrated AC & DC systems Harmonic Filters Database mapping via graphic user interface
Total bus & branch contribution fault currents Filter design & sizing
Fault current rising time Single-tuned, high-pass, & band-pass filters Microsoft Access & Excel Interface
Battery modeling per ANSI/IEC Standard Automatic filter overloading alert Map Access & Excel worksheets to ETAP elements
Charger modeling per ANSI/IEC Standard Inter-harmonic filter modeling Automatic one-line diagram generation
Synchronize data to ETAP projects
Battery Discharge & Sizing Perform consistency checks during data exchange
IEEE 308, 485, & 946 Standards Substitute missing information with ETAP defaults &
Integrated AC, DC, & Control System Diagram library data
Battery discharge simulation
Battery sizing e-DPP Interface
Discharge via DC load flow or duty cycle summation Map attributes of e-DPP to ETAP elements
Voltage drop & loss consideration Automatic one-line diagram generation
Class 1E DC power & control system models Synchronize e-DPP data to ETAP projects
Simulation of control system with battery discharge Database mapping via graphic user interface
voltage Panel Systems
Duty cycle diversity factor CAD Interface
Load model type per operating characteristics Panel ANSI & IEC Export one-line diagrams in DXF format
Battery duty cycle calculated from individual loads Intelligent panel design & analysis Import ground grid plans from AutoCAD
Options for battery & load duty cycle 1 min span 3-phase (3W & 4W) panels
Multiple user selected options for battery 1-phase (2W & 3W) panels
characteristic interpolation 1-phase (A, B, C, AB, BC, CA, & 3W) panels
Multiple diversity & correction factors ANSI & IEC Standards
Battery sizing report in IEEE 485 Standard format NEC load factors
Plot battery capacity, voltage, & current Load flow with graphical per phase display
Plot bus voltage & load & branch flow Automatic device duty evaluation & alerts
Detailed battery library Automatic updating of upstream panels
Export panel schedules to Excel
Panel with internal & external feeders & loads

ETAP Quality Assurance


OTIs Quality Assurance program is specifically dedicated to meeting the requirements of:

ISO 9001:2008 A3147 UL ETAP is Verified and Validated (V&V) against field results,
real system measurements, established programs, and hand
Control Systems 10 CFR 50 Appendix B calculations in order to ensure its technical accuracy. Each
release of ETAP undergoes a complete V&V process using
10 CFR 21
DC Control Systems Diagram thousands of test cases for each and every calculation module.
Simulation of operation sequence ANSI/ASME N45.2
Pickup & dropout voltage calculation ASME NQA-1
Automatic alerts
Burden & inrush modes ANSI/IEEE 730.1
Controlled contacts
CAN/CSA-Q396.1.2
Integrated with battery discharge calculation
ANSI N45.22
Real-Time Enterprise Solution

An Intelligent Energy Management System for


Operators, Managers, & Engineers
ETAP Real-Time is a suite of software tools that offers a fully integrated enterprise solution.
Through continuous monitoring, simulation, and optimization of electrical, process, manufacturing,
and management systems, ETAP can maximize the entire production process, reduce losses,
and increase profits.

ETAP Real-Time extends the traditional data acquisition systems to an intelligent and reliable power
management solution for operators, dispatchers, engineers, and decision makers. Its modular
functionality can be tailored to fit the needs of each company, from small to large power systems.
Industrial facilities, transmission, and distribution companies, generation owners, and vertically
integrated utilities can all benefit from the features and functionality of ETAP Real-Time.

Real-Time Energy Management Intelligent Load Intelligent


Monitoring & Simulation System Shedding Substation
Advanced Monitoring Automatic Generation Control Load Preservation Substation Automation
Intelligent graphical user interface Multi-area control Steady-state & transient response Flexible automation
State estimator & load distributor Load frequency control Optimal load preservation Programmable logic editor
Process & performance monitoring MW & Mvar sharing Fast response time Online control
Alarm & notification management NERC performance standard Reliable operation
Minimum load shedding Switching Management
Energy Accounting Economic Dispatch Proactive contingency analysis Switching sequence management
Energy tariff builder Minimize fuel costs Safety & security procedures
Customizable reports Optimize energy costs Load Restoration Interlock logic evaluator
Real-time energy cost tracker Fast solution Restart inhibition Switching plan validation
Cost & consumption summary Robust algorithms Logical load sequencer
Load restoration priority Load Management
Real-Time Simulation Supervisory Control Demand-side management
Simulate circuit breaker operation System optimization Load Shedding Validation Time-of-use load shifting
Identify potential operating problems Supervisory & advisory control system Confirm load shedding actions Intelligent load management
Simulate motor starting & load change Optimal power flow Simulate ILS recommendations
Predict operating time of protective Programmable logic editor Integrated stability knowledge base
devices
Predict system response based on Interchange Scheduling
operator actions Tariff analyzer
Perform What If operating scenarios Rate structure builder
Simulate real-time & archived data Transaction scheduling
Operator assistance & training Transaction contract ETAP Real-Time Brochure
Event Playback Reserve Management Please refer to the ETAP Real-Time
Replay archived historian data Operating reserve analysis brochure for detailed information.
Investigate cause & effect Reserve capacity monitoring
Explore alternative actions Notification of inadequate reserve
Replay What If scenarios View the brochure online at etap.com.
Predict operating reserve

Load Forecasting
Adaptive bus load forecasting
Real-time trending
Load profile library
Forecasting scenario archiving

Copyright 2009 Operation Technology, Inc. All rights reserved.


Certain names and/or logos used in this document may constitute trademarks, service marks, or trade names of Operation Technology, Inc. or other entities.

You might also like