NDE REQUEST

Tel:
From: AL-SINSINA CORNE
TO: ( DJC ) INSPECTION & ENGINEERING SERVICES.
Fax:
Client : AL-SINSINA CORNER COMPANY FOR CONTRACTING Our Job No: P-138 Test Location: DORA D

Project: DORA DORA-MEFSCO P.O./Contract No: N/A


RT o
Method:- PT o MT o UT o X-RAY Accept STD:- o ASME Sec IX o B 31.3

Joint
SR NO. Item Description(Name) Item / Spool Number Drawing/ISO Number Material Grade
JN: Number

1 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS1

2 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS2B

3 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L CS2

4 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS1ACS2-T

5 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L CS3

6 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS3ACS3-T

7 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L CS4

8 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS4BCS5-T

9 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS4

10 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS5A

11 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L CS6

12 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS5CCS6-T

13 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS6

14 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS7B


Form:Q39,R 0 Exhibit-39 , R 0
15 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS7ACS7-T

16 FRUCTOSE STORAGE TANK TANK# 041701-180 SCC-041701-180-141 A240 TP 316L LS7C

17 FRUCTOSE STORAGE TANK TANK# 041701-160 SCC-041701-160-141 A240 TP 316L (LS1CCS2-T) R1

18 FRUCTOSE STORAGE TANK TANK# 041701-160 SCC-041701-160-141 A240 TP 316L (LS1CCS2-T) P1

19 FRUCTOSE STORAGE TANK TANK# 041701-160 SCC-041701-160-141 A240 TP 316L (LS1CCS2-T) P2


Requested By: QCI
Signature: --------------------------------------------
Name: ABDUL HAFEEZ
Date: 11/11/2016

Form:Q39,R 0 Exhibit-39 , R 0
Request No: P-138/RT/094

Sheet : 01 of 02

From: AL-SINSINA CORNER COMPANY FOR CONTRACTING (DORA DORA SITE , AL


KHARJ)

Test Location: DORA DORA SITE , AL KHARJ

Date of start: 11/11/2016


ASME Sec VIII D.1 o API 1104

Joint Welder No.


Thickness Length Root Fill Cap REMARK

3MM 150 MM H20 H20 H20

3MM 150 MM V38 V38 V38

3MM 150 MM V38 V38 V38

3MM 150 MM H20 H20 H20

3MM 150 MM V67 V67 V67

3MM 150 MM S1 S1 S1

3MM 150 MM V68 V68 V68

4MM 150 MM V38 V38 V38

4MM 150 MM V38 V38 V38

4MM 150 MM V38 V38 V38

5MM 150 MM S1 S1 S1

4MM 150 MM S1 S1 S1

5MM 150 MM V68 V68 V68

5MM 150 MM V68 V68 V68


Form:Q39,R 0 Exhibit-39 , R 0
5MM 150 MM V38 V38 V38

5MM 150 MM S1 S1 S1

3MM 150MM V68 V68 V68

3MM 150MM V68 V68 V68

3MM 150MM V68 V68 V68


Approved By: QCM
-------------------------------------------------
Malik Nasar
11/11/2016

Form:Q39,R 0 Exhibit-39 , R 0