ALARM NAME SIGNAL COLOR


Lower oil level SWITCH_H17 White
GRND Blue
Generator working SWITCH_H18 White
GRND Orange
Generator failure SWITCH_H19 White
GRND Green
Main power failure SWITCH_H20 White
GRND Brown
AC power Failure SWITCH_H21 White
GRND Grey
DC voltage (higher/lower) SWITCH_H22 Red
GRND Blue
rectifier unit fault SWITCH_H23 Red
GRND Orange
battery LVD SWITCH_H24 Red
GRND Green
Aircondition1 Failure SWITCH_H25 Red
GRND Brown
Aircondition2 Failure SWITCH_H26 Red
GRND Grey
Temperature Alarm SWITCH_H27 Black
GRND Blue
Humidity Alarm SWITCH_H28 Black
GRND Orange
Door Alarm SWITCH_H29 Black
GRND Green
Smoke Alarm SWITCH_H30 Black
GRND Brown
Water Alarm SWITCH_H31 Black
GRND Grey
Commercial Power failure SWITCH_H32 Yellow
GRND Blue
Outdoor
ALARM NAME STARTPT SIGNAL COLOR
X1.19 SWITCH_H1 White
Lower oil level
X1.3 GRND Green
X1.18 SWITCH_H2 White
Generator 1 working
X1.2 GRND Orange
X1.21 SWITCH_H3 White
Generator 1 failure
X1.5 GRND Grey
X1.20 SWITCH_H4 White
Main Power Failure
X1.4 GRND Brown
X1.22 SWITCH_H5 Red
Generator 2 Running
X1.6 GRND Blue
X1.17 SWITCH_H6 White
Generator 2 failure
X1.1 GRND Blue
X1.23 SWITCH_H7 Red
X1.7 GRND Orange
X1.24 SWITCH_H8 Red
X1.9 GRND Brown
X1.25 SWITCH_H9 Red
X1.10 GRND Grey
X1.26 SWITCH_H10 Black
X1.11 GRND Blue
X1.27 SWITCH_H11 Black
X1.12 GRND Orange
X1.28 SWITCH_H12 Black
X1.13 GRND Green
X1.29 SWITCH_H13 Black
X1.14 GRND Brown
X1.35 SWITCH_H14 Black
X1.34 GRND Grey
X1.37 SWITCH_H15 Yellow
X1.36 GRND Blue
X1.38 SWITCH_H16 Red
X1.8 GRND Green

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.
Area: Delta- Sinai Region
Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
Pin assignment for the wires of the 120-ohm E1 twisted pair cable for RTN 950

Pair 1 Pair 2
Blue Orange Blue Orange
RX1 TX1 RX9 TX9
White White White White
Green Brown Green Brown
RX2 TX2 RX10 TX10
White White White White
Grey Blue Grey Blue
RX3 TX3 RX11 TX11
White Red White Red
Orange Green Orange Green
RX4 TX4 RX12 TX12
Red Red Red Red
Brown Grey Brown Grey
RX5 TX5 RX13 TX13
Red Red Red Red
Blue Orange Blue Orange
RX6 TX6 RX14 TX14
Black Black Black Black
Green Brown Green Brown
RX7 TX7 RX15 TX15
Black Black Black Black
Grey Blue Grey Blue
RX8 TX8 RX16 TX16
Black Yellow Black Yellow

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
Pin assignment for the wires of the 120-ohm E1 twisted pair cable
for RTN 620

NO Wire Color NO Wire Color


Blue Blue
RX1,9,17,25,33 TX1,9,17,25,33
White White
Orange Orange
RX2,10,18,26,34 TX2,10,18,26,34
White White
Green Green
RX3,11,19,27,35 TX3,11,19,27,35
White White
Brown Brown
RX4,12,20,28,36 TX4,12,20,28,36
White White
Gray Gray
RX5,13,21,29,37 TX5,13,21,29,37
White White
Blue Blue
RX6,14,22,30,38 TX6,14,22,30,38
Red Red
Orange Orange
RX7,15,23,31,39 TX7,15,23,31,39
Red Red
Green Green
RX8,16,24,31,40 TX8,16,24,31,40
Red Red
Pin assignment for the wires of the 120-ohm E1 twisted pair cable for NEC

NO Wire Color NO Wire Color


Grey- Black4 - - - - Brown
RX1,9,17,25,33 TX1,9,17,25,33
Grey-Black3 - - - Black
Grey-Black2 - - Purple-Red Long
RX2,10,18,26,3 TX2,10,18,26,3
4 4
Grey-Black1 - Purple-Red4 - - - -
Grey-Red4 - - - - Purple-Red2 - -
RX3,11,19,27,3 TX3,11,19,27,3
5 Grey-Red3 - - - 5
Purple-Red1 -
RX4,12,20,28,3
Grey-Red2 - - TX4,12,20,28,3 Yellow-Black Long
6 Grey-Red1 - 6
Yellow-Black4 - - - -
RX5,13,21,29,3 White-Black4 - - - - TX5,13,21,29,3 Yellow-Black3 - - -
7 7
White-Black3 - - - Yellow-Black2 - -

RX6,14,22,30,3 White-Black2 - - TX6,14,22,30,3 Yellow-Black1 -


8 8
White-Black1 - Yellow-Red Long

RX7,15,23,31,3 White-Red4 - - - - TX7,15,23,31,3 Yellow-Red3 - - -


9 9
White-Red3 - - - Yellow-Red2 - -

RX8,16,24,31,4 White-Red2 - - TX8,16,24,31,4


Grey-Black Long
0 0
Yellow-Red1 - White-Red1 -

Ground white-red Long


Ground White-black long
Ground grey-red long
Ground yellow-red4 - - - -
Ground purple-red3 - - -

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.
Area: Delta- Sinai Region
Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
Pin assignment for the wires of the 120-ohm E1 twisted pair cable for Node B
3900

NO Wire Color NO Wire Color


Blue Gray
RX1 TX1
White White
Orange Blue
RX2 TX2
White Red
Green Orange
RX3 TX3
White Red
Brown Green
RX4 TX4
White Red

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
Pin assignment for the wires of the 120-ohm E1 twisted pair cable for BTS
3900

NO Wire Color NO Wire Color


Gray Blue
RX1 TX1
White White
Orange Blue
RX2 TX2
White Red
Green Orange
RX3 TX3
White Red
Brown Green
RX4 TX4
White Red

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
Pin assignment for the wires of the 120-ohm E1 twisted pair cable for BTS
3012

NO Wire Color NO Wire Color


WHITE WHITE
RX1 TX1
ORANGE BLUE
WHITE WHITE
RX2 TX2
BROWN GREEN
RED WHITE
RX3 TX3
BLUE GREY
RED RED
RX4 TX4
GREEN ORANGE

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
Appearance of the EMU

This describes the appearance of the two EMU models.

Appearance of EMU model A

Figure 1 and Figure 2 show the appearance of EMU model A and its front panel respectively.

Figure 1 Appearance of EMU model A

Figure 2 Front panel of EMU model A

(1) Six ports for Boolean signal output (2) Port for water sensors
(3) Port for door status sensors (4) Port for smoke sensors
(5) Port for humidity/temperature sensors (6) Port for infrared sensors
(7) Four ports for analog signal sensors (8) RS-232 port
(9) Active/standby power port (10) Two RS-485 ports
(11) Grounding screw (12) Thirty-two ports for Boolean signal sensors
Appearance of EMU model B
Figure 3 and Figure 4 show the appearance of the EMU model B and its front panel respectively

Figure 3 Appearance of EMU model B

Figure 4 Front panel of EMU model B

(1) Six ports for Boolean signal output (2) Port for water sensors
(3) Port for door status sensors (4) Port for smoke sensors
(5) Port for humidity/temperature sensors (6) Port for infrared sensors
(7) Four ports for analog signal sensors (8) RS-232 port
(9) Active/standby power port (10) Two RS-485 ports
(11) Grounding screw (12) Thirty-two ports for Boolean signal sensors

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
ALARM NAME Boolean Value
Aircondition1 Failure 1
Aircondition2 Failure 2
Generator failure 3
gen not outo 4
Generator working 5
battery charge 12
Main power failure 13
DC voltage (higher/low 14
rectifier unit fault 15
battery LVD 16
Water Alarm 17
Temperature Alarm 18
Smoke Alarm 19
Door Alarm 20
Humidity Alarm 24
ALARM NAME Boolean Value
Aircondition1 Failure 1
Aircondition2 Failure 2
Generator failure 3
gen not outo 4
Generator working 5
battery charge 12
Main power failure 13
DC voltage (higher/low 14
rectifier unit fault 15
battery LVD 16
Water Alarm 17
Temperature Alarm 18
Smoke Alarm 19
Door Alarm 20
Humidity Alarm 24
Colors and Wiring Guide Diagram for the 120-ohm twisted pair cable for RJ

Basic Theory: T-568A Straight-Through

By looking at a T-568A UTP Ethernet straight-thru cable and an Ethernet


crossover cable with a T-568B end, we see that the TX (transmitter) pins are
connected to the corresponding RX (receiver) pins, plus to plus and minus to
minus. You can also see that both the blue and brown wire pairs on pins 4, 5,
7, and 8 are not used in either standard. What you may not realize is that,
these same pins 4, 5, 7, and 8 are not used or required in 100BASE-TX as
well. So why bother using these wires, well for one thing its simply easier
to make a connection with all the wires grouped together. Otherwise you'll be
spending time trying to fit those tiny little wires into each of the
corresponding holes in the RJ-45 connector

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
ted pair cable for RJ45

T-568A Straight-Through Ethernet Cable


Wiring Guide Diagram cable for RTN 9(male) -9(female) connector

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
nnector
Wiring Guide Diagram cable for NEC V4 9(male) -15(female) connector

BR
Mostafa Mohamed Talaat
BSS O&M Eng.
ALKAN Networks O&M BU.

Area: Delta- Sinai Region


Office: Zagazig
Mobile: 0116606995
Email: Mostafa.Talaat@alkancit.com
www.alkancit.com
connector

You might also like