You are on page 1of 2

2017.08.12 15:00:29 - Year.Month.

Day - Log start

BUNDLE: SIMATIC STEP 7 Professional V14.0


SEBU Version: PROFESSIONAL:TIA.rgs.RTM_14000000:V14.00.00.00_31.01.00.01

OS: Microsoft Windows7 dition Familiale Premium Home Premium Edition, Service
Pack 1, 64-bit, build 7601
COMMANDLINE: C:\Program Files (x86)\Common Files\Siemens\Automation\Siemens
Installer Assistant\400\SIA2.exe /starter
/bundlepath=C:\USERS\JAMAL\APPDATA\LOCAL\TEMP\SIMATIC STEP 7 PROFESSIONAL
V14.0\InstData
INSTALLDIR: C:\Program Files\Siemens\Automation
SETUPLANGUAGE: 1036
PRODUCTLANGUAGES: 1033;1036

CHANGES: (o)NCMFWL64;(+)INSTSQL2014EXP;(+)CONFSQL2014EXP;(o)S7EDB;(+)TIA_Portal;
(+)MU_Client;(+)HWCN-HWCOL;(+)SUPBASEH02;(+)SUPBASEH03;(+)SUPBASETO01;
(+)SUPBASETO02;(+)SUPBASEWCF01;(+)TIAP_SIMATIC;(+)TIAP_SIMATIC32;(+)STEP7;
(+)HM_AllEditions;(+)HM_NoBasic;(+)TIA_ES;(+)TIA_ES32;(+)WinCC_TrC_All;
(+)WinCC_TrL_All;(+)TIACOMPCHECK

There are NO severe messages before the installation

15:00:29 | BEGIN. Execution started.


15:00:34 | OK RunningProcesses (), Complete
15:00:35 | OK InventoryBefore (A), Complete
15:00:35 | OK Citamis (Before), Complete
15:00:53 | OK SecurityControlFeature (ReturnFeatures),
Complete
15:00:53 | OK StartApplBefore (TIAP14::
[INSTALLDIR]BIN\SIEMENS.AUTOMATION.OBJECTFRAME.FILESTORAGE.SERVER.EXE), Complete
15:00:53 | OK StartApplBefore (TIAP14::
[INSTALLDIR]X64\BIN\SIEMENS.AUTOMATION.OBJECTFRAME.FILESTORAGE.SERVER.EXE),
Complete
15:00:54 | OK ClassicCompPrepare (), Complete
15:00:54 | OK ProductRegistration (Before), Complete
15:03:00 | OK SetupUnit (NCMFWL64), Complete - -
ClassicComponent, Reinstall
15:16:38 |ERROR AdsWorkerClassicProduct::OnWorkerCompleted(): - ClassicProduct
setup result: 0: Please find the Microsoft SQL Server log files for more details
at: C:\Program Files (x86)\Microsoft SQL Server\120\Setup Bootstrap\Log\Summary.txt
or refer files under
15:16:39 | FAIL! SetupUnit (INSTSQL2014EXP), Failed - -
ClassicProduct, AddLocal
15:16:39 | OK CallCurrentAfterReboot SetupUnit (CONFSQL2014EXP), Complete - -
ClassicProduct, AddLocal
15:16:39 | SKIP! SetupUnit (S7EDB), Skip - - ClassicComponent,
Reinstall
15:16:39 | SKIP! SecurityControl (TIA_Portal), Skip;Before
15:16:39 | SKIP! SetupUnit (TIA_Portal), Skip - - PlusMain,
AddLocal
15:16:39 | SKIP! SecurityControl (TIA_Portal), Skip;After
15:16:39 | SKIP! SetupUnit (MU_Client), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (HWCN-HWCOL), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (SUPBASEH02), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (SUPBASEH03), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (SUPBASETO01), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (SUPBASETO02), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (SUPBASEWCF01), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (TIAP_SIMATIC), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (TIAP_SIMATIC32), Skip - -
PlusOptional, AddLocal
15:16:39 | SKIP! SetupUnit (STEP7), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (HM_AllEditions), Skip - -
PlusOptional, AddLocal
15:16:39 | SKIP! SetupUnit (HM_NoBasic), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (TIA_ES), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (TIA_ES32), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (WinCC_TrC_All), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (WinCC_TrL_All), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! SetupUnit (TIACOMPCHECK), Skip - - PlusOptional,
AddLocal
15:16:39 | SKIP! ClassicCompAfterInstall (), Skip
15:16:39 | SKIP! ClassicCompRollback (), Skip
15:16:39 | SKIP! HspInstall (), Skip
15:16:39 | SKIP! MspInstall (), Skip
15:16:39 | SKIP! StartApplAfter (TIAP14::
[INSTALLDIR]BIN\INSTALLROOTCERTIFICATE.EXE), Skip
15:16:39 | SKIP! StartApplAfter (TIAP14::
[INSTALLDIR]BIN\SIEMENS.AUTOMATION.GENERATOR.FRAMEWORK.EXE), Skip
15:16:39 | SKIP! StartApplAfter
(TIAP14::C:\WINDOWS\SYSWOW64\S7EPATSX.EXE), Skip
15:16:39 | SKIP! StartApplAfter
(TIAP14::C:\WINDOWS\SYSWOW64\S7EPAESX.EXE), Skip
15:16:39 | SKIP! StartApplAfter (TIAP14::
[INSTALLDIR]BIN\SIEMENS.SIMATIC.HWCN.INTERPRETER.IG.GSD.GENERATOR.EXE), Skip
15:16:39 | SKIP! ProductRegistration (After), Skip
15:16:39 | SKIP! SetupIsComplete (), Skip
15:16:39 | SKIP! InventoryAfter (Z), Skip
15:16:39 | SKIP! LicenseTransfer (), Skip
15:16:39 | SKIP! SetupReport (), Skip
15:16:42 | OK ImmediateReboot (), Complete
15:16:42 | OK Citamis (After), Complete
15:16:42 | OK SetupSummary (), Complete
15:16:42 | END. Execution completed.

Intermediate ExitCode after execution queue: 1603


Errors: 1
Warnings: 0