Two sensor head tests were conducted on December 15, 2016 to test LEDs and measure current. Current was injected through LEDs and measured through photodiodes. Sensor heads S06-X5 and S02-X5 were tested, with different resistor values and flexed membrane output voltages measured for each. Data from the tests was recorded in an attached spreadsheet.
Two sensor head tests were conducted on December 15, 2016 to test LEDs and measure current. Current was injected through LEDs and measured through photodiodes. Sensor heads S06-X5 and S02-X5 were tested, with different resistor values and flexed membrane output voltages measured for each. Data from the tests was recorded in an attached spreadsheet.
Two sensor head tests were conducted on December 15, 2016 to test LEDs and measure current. Current was injected through LEDs and measured through photodiodes. Sensor heads S06-X5 and S02-X5 were tested, with different resistor values and flexed membrane output voltages measured for each. Data from the tests was recorded in an attached spreadsheet.
-Injected Current through LED side and measured current
through Photo diode side
<<Sensor Head Test - Spreadsheet.xlsx>>
Used S06-X5 (001-0016-X5) to test LEDs below.
Injected Current from R4 Measured Detector Current from R7 R5 and R6 replaced with one 50 ohm? R3 = 2M Ohm Flexed membrane Output Voltage: 2.2V <<Sensor Head Test - Spreadsheet.xlsx>>
Used S02-X5 (001-0016-X5) to test LEDs below.
Injected Current from R4 Measured Detector Current from R7 R5 and R6 replaced with one 50 Ohm? R3 = 1M Ohm Flexed membrane Output Voltage: 1.648V