You are on page 1of 2

RoCombo MFL-A/IEC Service

in-line complementary combined


metal loss detection and sizing

The increasing requirement for higher op- Key Advantages


erational pressure in the offshore industry is Accurate and precise detection and sizing of shallow
internal corrosion by high density of eddy current sensors
typically met by extra heavy wall pipelines.
and high sampling rates combined with accurate and
For these assets it is important to identify any precise feature classification and sizing by magnetic
complex corrosion at a very early stage to saturation, high sensor density, high sampling rates and
adapt the operational strategy, e.g. by applying triaxial magnetic field analysis.
Lifetime integrity management supported by full
inhibitors, dewatering or inline cleaning.
recording of the complete inspection raw data.
Our RoCombo MFL-A/IEC service provides High availability and a wide range of proven tool
reliable and accurate detection and sizing of configurations addressing individual operational pipeline
requirements.
complex corrosion as an proactive basis for a
High quality service with certified processes (API 1163),
successful and effective pipeline integrity man- personnel qualification (ASNT) and equipment (CE, ATEX).
agement.

The solution
To enhance the measurement performance in heavy
walled pipelines, a combination of Magnetic Flux Leakage
(MFL) and Eddy Current is utilized on one tool. The two
technologies are well-established within the industry and
represent a robust inspection method with high sensitivity
and accuracy. The unique approach ensures not only high
sensitivity and precision when scanning the inner pipe for
metal loss anomalies with the Eddy Current technology, but
it also provides comprehensive geometry inspection data.
Besides that, the simultaneous utilization of MFL provides
reliably additional data for mid-wall and external features.
The modular tool design allows a quick adaptation to service options
current needs in terms of tailored solutions. All aspects from the inspection request to the final report
are covered with the flexibility to choose from various
Recent advances in capabilities of the inspection tools have service options.
furthermore extended the application range to pipelines Cleaning operational and pre inspection
that were used to be classified as unpiggable. Among those Speed Control inspection at high flow rates
are not only multi-diameter pipeline configurations which GEO geometry mapping available on MFL-A/IEC tool
were not inspectable previously, but also pipelines with XYZ route mapping and strain assessment
high wall thicknesses and uncommon operating conditions. Multi-Diameter pipelines with varying diameter
Offshore long distance and high pressure
Post ILI data alignment and combined evaluation
Integrity RBI, FFP, CGA
ROAIMS versatile asset integrity software suite

www.rosen-group.com
RoCombo MFL-A/IEC Service
in-line complementary combined metal loss detection and sizing

Technical Specifications
Standard Operating Specifications Metal Loss Feature Classification
Tool sizes available 6"56" All reported metal loss features are classified according to
Pipeline product Gas or liquids the dimensions shown in the following Pipeline Operators
Product temperature range 0 C65 C (32 F149 F) Forum (POF) specification graph.
Maximum operating pressure 15 MPa (2175 psi)
A = wall thickness or 10 mm (0.39"), whichever value is greater
25 MPa (3625 psi) optional
Operating speed range Up to 5.0 m/s (11.2 mph)

Width/A

Circumferential grooving
Minimum pipeline bend radius 1.5D
Maximum operating time 400 hours 8

Circumferential slotting
Maximum inspection length 800 km (500 miles)
7
Note: Contact ROSEN for more detailed information.

6
Location and Orientation Capabilities
5 General
Axial position accuracy from reference marker 1:1000
1 m on 1000 m (1 ft on 1000 ft) marker distance
4
Axial position from closest weld 0.1 m (4")
Circumferential position accuracy 10 3
The axial positioning accuracy specified is based on following criteria:
Distance between upstream and downstream marker/reference point 2 Pitting Axial grooving
< 2000 m (1.2 miles)
Actual above ground distance to both upstream and downstream 1
marker/reference points to be measured and correlated
Negligible difference between pipeline and soil contour Axial slotting
1 2 3 4 5 6 7 8
Pinhole Length/A

Wall Thickness Detection


1 mm ( 0.04") or 0.1t, whichever value is greater at
80% certainty
t = wall thickness

Sizing Capabilities

General Pitting Axial grooving Circ. grooving


Non Non Non Non
Internal1 internal Internal2 internal Internal2 internal Internal2 internal
Depth at POD = 90% [mm] 1.5 mm 0.10t 1.8 mm 0.10t 1.8 mm 0.10t 1.5 mm 0.10t
(0.06") (0.07") (0.07") (0.06")
Depth sizing accuracy at 80% certainty 1.3 mm 0.10t 1.5 mm 0.10t 1.5 mm 0.15t 1.3 mm 0.10t
(0.05") (0.06") (0.06") (0.05")
Length sizing accuracy at 80% certainty 6 mm 15 mm 3 mm 10 mm 3 mm 10 mm 6 mm 10 mm
(0.24") (0.59") (0.12") (0.39") (0.12") (0.39") (0.24") (0.39")
Width sizing accuracy at 80% certainty 5 mm 15 mm 3.5 mm 12 mm 3.5 mm 12 mm 5 mm 15 mm
(0.20") (0.59") (0.14") (0.47") (0.14") (0.47") (0.20") (0.59")
Abbreviations: POD = Probability of Detection; t = wall thickness
1
General metal loss and other classes, if width > 30 mm (1.2")
2
For width = length < 30 mm (1.2")

Remarks and Features


Other tool sizes are available on request
Higher pressure rating available on request
Tailored solutions with different specifications available
API 1163 certified services
CE and ATEX certification available
Contact ROSEN for more detailed information about the presented service
Specifications are subjected to change according to specific requirements
or tool configurations

2013 ROSEN Swiss AG. All Rights Reserved.


RoComboMFL-A/IEC_SF_E_CMR_2.1_201310

www.rosen-group.com

You might also like