INDEX SHEET FOR SCHEDULE OF VALVE AND SPECIALTIES

PROJECT : SURATGARH 2X660MW SUPER THERMAL POWER STATION

CUSTOMER : RRVUNL

REF DRG NO :

SYSTEM : ACID CLEANING PIPING

CUST NO : 7198

DATE OF REVISION

SHEET NO REV 00 REV 01 REV 02 REV 03 REV 04 REV 05

01 14.05.14

02 14.05.14

03 14.05.14

04 14.05.14
PREPARED I.D.B.RAJU BHEL PC DRG NO:

CHECKED S RAMAMURTHY 4-00-306-40422

APPROVED KVR SHEET 1 OF 3


ET FOR SCHEDULE OF VALVE AND SPECIALTIES

X660MW SUPER THERMAL POWER STATION

DATE OF REVISION

REV 06
BHEL PC DRG NO:

4-00-306-40422

SHEET 1 OF 3
BHEL
SCHEDULE OF VALVES & SPECIALITIES
LA05 PIPING CENTRE
Ref. Drg.No : Customer Nos : 7198
System : ACID CLEANING PIPING Project : SURATGARH 2X660MW STPS
Customer : RRVUNL

Tag No / Valve Size Max.working parameters Detail Matching Pipe Rel


Type No Off Operation Supply Service
KKS No Nb Class Pr(kg/cm2(g)) Temp(oC)
Body End Od Thk Sty d1 PGMA

CL STY 'D' -
AC-01 GATE 300 5 40.0 80 HW WCB BW 323.9 12.7 d1= 298.9
BHEL(T) ACID CLEANING SYSTEM -
300

CL STY 'D' -
AC-02 GATE 250 7 40.0 80 HW WCB BW 273 9.27 d1= 254.5
BHEL(T) ACID CLEANING SYSTEM -
300

CL STY 'D' -
AC-03 GLOBE 250 2 40.0 80 HW WCB BW 273 9.27 d1= 254.5
BHEL(T) ACID CLEANING SYSTEM -
300

CL STY 'D' -
AC-04 NRV 300 5 40.0 80 FLAP WCB BW 323.9 12.7 BHEL(T) ACID CLEANING SYSTEM -
300 d1= 298.9

CL STY 'D' -
AC--05 GATE 200 6 40.0 80 HW WCB BW 219.1 8.18 d1= 202.7
BHEL(T) ACID CLEANING SYSTEM -
300

GATE CL STY 'D' -


AC-06 150 3 40.0 80 HW WCB BW 168.3 7.11 d1= 155.6
BHEL(T) ACID CLEANING SYSTEM -
VALVE 300

CL STY 'D' -
AC-07 GATE 100 4 40.0 80 HW WCB BW 114.3 6.02 d1= 103.5
BHEL(T) ACID CLEANING SYSTEM -
300

ALTD: ALTD: REV DATE ALTD:


REV 01 DATE REV 02 DATE
APPD: APPD: 03 APPD:
DRG. NO.

Prepared by: Checked by: Approved by: DATE : DRG NO : 4-00-306-40422


I.D.B.RAJU S RAMAMURTHY K.V.R. SHEET NO : 2 OF 3
& SPECIALITIES

SURATGARH 2X660MW STPS


RRVUNL

Specialties Remarks

0
1
0
1
0
0
1
1
0
1
0
0
1
1
0
1
0
0
1
2
0
1
0
1
0
0
DRG. NO.
1
2
0
DRG NO : 4-00-306-40422 REV 2

SHEET NO : 2 OF 3 00
BHEL
SCHEDULE OF VALVES & SPECIALITIES
LA05 PIPING CENTRE
Ref. Drg.No: : Customer Nos : 7198
System : ACID CLEANING PIPING Project : SURATGARH 2X660MW STPS
Customer : RRVUNL

Tag No / Valve Size Max.working parameters Detail Matching Pipe


Type No Off Operation Supply Service
KKS No Nb Class Pr(kg/cm2(g)) Temp(oC)
Body End Od Thk Sty d1

CL
AC-08 GATE 50 20 40.0 80 HW A105 SW 60.3 5.54 - BHEL(T) DRAIN VALVE
800

CL
AC-09 GATE 25 20 40.0 80 HW A105 SW 33.4 4.55 - BHEL(T) DRAIN & VENT
800

ALTD: ALTD: REV DATE ALTD:


REV 01 DATE REV 02 DATE
APPD: APPD: 03 APPD:
DRG. NO.

Prepared by: Checked by: Approved by: DATE : DRG NO : 4-00-306-40422


I.D.B.RAJU S RAMAMURTHY K.V.R. SHEET NO : 3 OF 3
S & SPECIALITIES

SURATGARH 2X660MW STPS


RRVUNL

Rel
Specialties Remarks
PGMA

0
1
0
1
0
0
1
1
0
1
0
0
DRG. NO.
1
2
0
DRG NO : 4-00-306-40422 REV 2

SHEET NO : 3 OF 3 00