030 Piling m

INFORMATION PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENT ARY
INFORMATION
P1 The following information is shown either on location drawings under A Preliminaries/General conditions or on further drawings
which accompany the bills of quantities:
(a) the general piling layout
(b) the positions of different types of piles
(c) the positions of the work within the site and of existing services
(d) the relationship to adjacent buildings
P2 Soil description:
(a) the nature of the ground is given in accordance with Section 020 Information Provided
(b) where work is carried out near canals, rivers, etc. or tidal waters, the level of the ground in relation to the normal levels of
the canal or river etc. or to the mean Spring levels of high and low tidal waters. is stated: Hood levels are stated where
app~cable
P3 Commencing levels:
(a) the levels from which the work is expected to begin and from which measurements have been taken are stated; irregular
ground is so described

CLASSIFICATION TABLE
CAST IN PLACE CONCRETE PILING
1 Bored piles 1 Nominal diameter stated 1 Total number, nr 1 Preliminary piles M1 Bored and driven 01 Piles comprising a C1 Total concrete Sl Kind and quality of
2 Driven shell piles commencing surface 2 Contiguous bored piles lengths are measured driven light gauge casing length is deemed to materials and mix details
stated along the axes of the which is first filled with include concrete
3 Secant piles S2 Tests of materials
piles from the concrete and then withdrawn placed in excess of the
2 Total concreted length m 4 Raking, inclination ratio commencing surface are classed as driven shell completed length S3 Type of grout
stated to the bottom of the piles where the piles are
3 Total bored or driven shafts of bored piles
S4 Details of compaction
m designed for the load to be C2 Pre-boring is deemed to
length. maximum and to the bottom of carried on the concrete include grouting up voids
lenoth stated the casings of driven
piles 02 Filling such piles is not between sides of piles and
3 Pre-boring driven piles 1 Maximum depth staled m classed as filling hollow piles bores
in accordance with Section
M2 Pre-boring is only 030.20.1..
measured where it is
4 Backfilling empty bores 1 Type of backfill material m specifically reQuired
stated

5 Items extra over piling 1 Breaking through h M3 Breaking through


obstructions obstructions is only
measured where
obstructions are
encountered above the
founding stratum of the pile

2 Enlarging bases for bored 1 Diameter of enlarged nr C3 The work is deemed to


piles base stated include work below the
3 Enlarging bases for driven specified bottom
shell piles