METHOD OF MEASUREMENT
FOR ROAD WORKS (MORTH)
By
V R K Murty
METHOD OF MEASUREMENT FOR ROAD WORKS
3. Bituminous pavement 1. Filling pot holes shall be measured in sqm. and filling
layers cracks > 3mm in width shall be measured in Rm. The
rate shall include for breaking out, trimming edges,
cleaning out painting edges and bottom with bitumen
and filling and compacting with material specified
2. Profile correction course shall be measured in cum
3. Prime coat and tack coat shall be measured in sqm
4. BM/DBM/BC shall be measured in cum or by weight in
metric tons, or in sqm. where specified thickness has
been executed. Penetration macadam shall be measured
in sqm.
METHOD OF MEASUREMENT FOR ROAD WORKS
The current rating of switches for domestic and similar purposes are
6A, and 16A.
METHODS OF MEASUREMENT FOR SERVICES
Conversion Factors:
1. KW = KVA x PF (PF 0.8 – 0.85)
Watt (Load including inductive load)
E.g. 100 KVA x 0.8 = 80KW
2. VA = Amp x Volts/PF
3. 1 HP = 0.7457 KW
4. Diversity factor = Diversified load
Max. System load
METHODS OF MEASUREMENT FOR SERVICES
Sl.No. Description Details
1. Lighting circuit Up to 10 points or 800W which ever is less
2. Power circuit Residential < 2 Nos. 5A/15A
Non residential 1 No. 5A/15 A
3. Plug socket In residential plug socket shall be of copper cable
4. Minimum size of Lighting 1.5 sq.mm. / Power circuit 4 sq.mm.
wire
5. Ht. of plug socket 5A/15A, 23 cm. from floor, kitchen 23cm. Above
platform, bath 2.1m (MCB)
6. Switch box 1.20m.
7. Steel conduit 20mm. minimum (1.6mm th.) up to 32mm.dia. (2mm
th.)
8. Mild steel box 1.20mm th. (20x30 cm.), 1.60mm. th. for larger size
9. Depth of junction 65mm.
box
10. Fish wire 16 g.
WATER SUPPLY PLUMBING
Stand ard meth od s of meas uremen t
Ducting:
1. Rectangular duct work shall be measured by weight,
based upon the area calculated as the length, taken
along the centre line over all fittings.
2. Blank ends shall be added to the area but no
deductions shall be made for intersections and
openings. Extra weight of seams, stiffeners,
supports, fixings or the like shall be understood to
be included.
3. Circular, oval and flexible duct work shall be
measured by length taken along centre line over all
fittings.
Stand ard meth od s of meas uremen t
Ducting:
4. Fittings to rectangular duct work shall be understood
to be included. Fittings to circular and oval duct
work shall be enumerated.
5. Dampers, grilles, flexible connectors or the like shall
be enumerated.
6. Accessories or activating devices (thermostats,
humidistats, motorised valves), control panels, air
compressors shall be enumerated. Wiring,
pneumatic tubing, isolators, starters, relays or like
associated with automatic controls shall be
understood to be included.