Professional Documents
Culture Documents
UDC 669.5: 545.33 : 669.4 + 669.73 Ref. No. ISO 713-1975 (E)
Descriptors: zinc. chemical analysis, determination of content, lead, cadmium, polarographic analysis.
. -
713-75 ~ 4851903 0070445 5
II
FOREWORD
Prior to 1972, the results of the work of the Technical Committees were published
as ISO Recommendations; these documents are now in the process of being
transformed into International Standards. As part of this process, Technical
Committee ISO/TC 18 has reviewed ISO Recommendation R 713 and found it
technically suitable for transformation. International Standard ISO 713 therefore
replaces ISO Recommendation R 713-1968 to which it is technically identical.
ISO Recommendation R 713 was approved by the Member Bodies of the following
countries:
Belgium India Spain 713-75 ~ 4851903 0070445 5
Brazil Ireland Swjtzerland
Canada
Chile
Czechoslovakia
Italy
Japan
Korea, Rep. of
Thailand
Turkey
United Kingdom
II
Egypt, Arab Rep. of Korea, D.P. Rep. of U.S.A.
France New Zealand U.S.S.R.
Germany Norway Yugoslavia
Hungary South Africa, Rep. of
Australia
Spain
Printed in Switzerland
INTERNATIONAL STANDARD
713-75 I 0070446 7 ~ ISO 713-1975 (E)
4851903
4.2.1 Take three 5 g test portions of Zn 99,995 zinc or 4.8 Lead and cadmium, standard solution No.2.
Zn 99,99 zinc for die castings.
Dilute the standard lead and cadmium solution No.1 (4.7)
4.2.2 Attack the first and second test portions with 35 to in the proportion of 1 part to 9 parts of water.
40 ml of hydrochloric acid (4.2). as indicated under 7.3, 1 ml of this solution contains 0,1 mg of lead and 0,1 mg of
starting at 7.3.2. cadmium.
1) Although these types of zinc do not normally contain any thallium or indium, these two elements, if present, can interfere in this
determination.
1
ISO 713-1975 (E) 713-75 I 4851903 0070447 9
4.9 Lead and cadmium, standard solution No.3. 7.2.2 Evaporate to a syrupy consistency and proceed as
outlined in 7.3.3 to 7.3.5, then polarograph as outlined
Dilute the standard lead and cadmium solution No.2 (4.8) in 7.4.
in the proportion of 1 part to 9 parts of water.
1 ml of this solution contains 0,01 mg of lead and 0,01 mg 7.2.3 Construct a calibration curve from the step heights
of cadmium. obtained.
4.10 Zinc chloride, solution free from lead and cadmium. 7.3 Determination
Sampling shall be carried out in accordance with the Polarograph between 0 and - 1 V.
requirements of ISO 3751. The step for lead occurs at about - 0.4 V and the step for
cadmium at about - 0,6 V relative to a mercury electrode
or, respectively, at - 0,65 V and - 0,85 V relative to a
7 PROCEDURE saturated calomel electrode.