You are on page 1of 75

VRLA HANDBOOK

ENGLISH INDUSTRIAL BATTERIES

APPLICATIONS 4.75 6.35


+1.5
UPS
98 -0.5

6.35

4.5
Emergency lights

3.2
Wind turbines
Wheelchairs
Solar or wind powered street lighting (187)
Yacht
(250)
+1.5
Mobile surgery light +1.5
151-0.5
Solar powered advertising displays 34 -0.5
Mobile floor sweepers
Golf buggies 130.3
6

Cleaning robots
Telecommunication
Motorcycle
Construction sites signalling
Ticketing machine, etc.
+1.5
94 -0.5

M5 165±2
(134)
11.8

(8)
0.3

(A)
(90)
150.2 33.2

11 M5
(16.5)
(12)
12.5

(L)
175±2
181±2 76±2
1.7

112.7
11.8

(163.4)
167±2

+1.5
151 -0.5

13.5±0.75
(179.5) (74.5)
+1.5
151-0.5
(6)

130.3
.5
.5
INDEX
Chapter Page
Battery Finder App 2
Panasonic Batteries: company, certifications and key benefits 4–5
‘eco ideas’ strategy 6–7
1 Precautions for handling VRLA batteries 8 – 13
2 General information 13 – 16
3 Characteristics 16 – 19
4 Charging methods 20 – 24
5 Terminal data 25
6 Safety 26
7 Safety design 26 – 27
8 Model numbers of VRLA batteries 28 – 29
9 Battery label design 30
10 Battery selection guide 31
Designed for engineers, electronics specialists and developers who 11 Battery index 32 – 35
need batteries for their projects, the Battery Finder App provides 12 Standards 36 – 37

an overview of what’s available in the Panasonic range of indus- 13 Individual data sheets 38 – 143
14 Glossary of main battery terms 144 – 147
trial batteries, and gives a recommendation on the type of battery
that’s best suited to the user’s application. It also offers a wealth of
informa­tion, diagrams and animations on battery technology.

Scan QR code to go to app store and


download app free of charge.

HOME COMPANY INFORMATION BATTERY INFORMATION TECHNICAL DRAWINGS


The welcome screen. You can start This is a brief profile of Panasonic, You’re shown the selected battery You can view a detailed technical
looking for a battery straight from telling you about the company with all the key details. You have drawing of the battery and zoom
here, or check out the information and its industrial batteries divi- also several options for requesting in on particular details.
on Panasonic and details on bat- sion. You might also like to view downloads and hardcopies.
tery technologies. Good luck! our ‘eco ideas’ film.

2 3
PANASONIC BATTERIES

PANASONIC INDUSTRIAL DEVICES SALES EUROPE


Panasonic Corporation, founded in Osaka 1918, is one of the world’s largest manufacturers of quality
electronic and electrical equipment. Its subsidiary, Panasonic Industrial Devices Sales Europe GmbH
(PIDSEU) markets a diverse portfolio of industrial products throughout Europe. Formed in 1998 to
strengthen Panasonic’s pan-European industry operations, the company is now active in Automotive, Panasonic quality –
certified by authorised
Distribution, Appliance, Industry as well as Factory Solutions and Energy. agencies.

Company Certifications Our batteries all deliver three key benefits


Panasonic offers a wide range of power solutions for portable Panasonic Energy Company (PEC) began manufacturing Our production facilities use leading-edge manufacturing
and stationary applications. Our product range includes high batteries in 1931. Today PEC is the most diversified global processes that meet the toughest quality standards. All our

POWER
reliability batteries such as Lithium-Ion, Lithium, Nickel- battery manufacturer worldwide, with an extensive network factories are certified to ISO standards – with ISO 9000 and
Metal-Hydride, Valve-Regulated-Lead-Acid (VRLA), Alkaline of manufacturing companies globally. The company employees ISO 14000 being the minimum benchmarks. This means each

SAFETY
and Zinc-Carbon. With this breadth and depth to the portfolio, are dedicated to research, development and production of factory has its own quality and environmental management,
we can power your business in virtually all applications. batteries for an energized world. and delivers products that measure up to toughest standards

LONG-LIFE
of reliability.

Most of our factories are also certified to OHSAS 18001


AUTOMOTIVE
FACTORY SOLUTIONS
(Occupational Health and Safety Assessment Series), an
international standard to assess the management system
DISTRIBUTION
which organisations have in place for occupational safety. P
 ower – is the basic customer requirement for all our
This confirms our factories have been proactive in putting batteries. Find out how we can power your business!  
ENERGY
PIDSEU the occupational health and safety of staff at the centre of S
 afety – our highest priority! We provide only safe
the company’s dealings. In addition our VRLA batteries are products – for your peace of mind!

APPLIANCE
for example approved to German VdS standard and the US L
 ong-life – only reliably-designed batteries provide the

INDUSTRY PIDSEU organisation UL standard. long service life you need to power your applications.

4 5
‘eco ideas’ STRATEGY

STAKEHOLDER
BIODIVERSITY
RESOURCES

CHEMICALS

BY-REGION
ECO IDEAS

WATER
CO2

VIDEO

PANASONIC LEADS THE WAY ... WITH ‘eco ideas’ GREEN BATTERY APPLICATIONS
Pursuing coexistence with the global environment in its business vision, Panasonic is committed – Working for future generations, Panasonic aims to become the No.1 Green
in all its business activities – to reducing the environmental impact of its products. In its ‘eco Innovation Company in the Electronics Industry. With this commitment in mind, we
ideas’ Strategy, Panasonic focuses in particular on rapid implementation of measures to pre- are focusing on green battery applications such as wind turbines, e-bikes and solar
vent global warming, and on global promotion of environmental sustainability management. street lighting. Take a look at this video – and see how we can power your business. Scan QR code to
view 3D animated
video.

CO2 enhance its recycling-oriented manufacturing with the effec- This raises concern about the impact on human health and Stakeholder
Panasonic strives to increase the use of products with higher tive use of finite resources. the environment. Panasonic cannot bring forth green innovations on a global
energy efficiency and energy-creating products such as photo­­- To reduce the impact on the environment, Panasonic will scale without the collaboration with the society, including our
voltaic power generation systems and fuel cells to decrease Water voluntarily decrease, substitute or discontinue the use of customers worldwide, experts, and the supply chain.
CO 2 emissions from customers‘ homes. Water is vital for life, as well as for manufacturing products. chemical substances in each phase throughout the cycle from Panasonic hopes for close communication through initiatives
Together with the effort to improve energy efficiency of its It is said that available fresh water is only about 0.01% of procurement of materials to production, use, and recycling of such as tree planting activities and environmental education
production activities, Panasonic will reduce CO 2 emissions the Earth‘s total water resources. To make the most of finite products. programs for children worldwide to extend green innovations
in every phase of its business activities, aiming for total CO 2 water resources, Panasonic is committed to pursuing water that lead to sustainable lifestyles across the world.
emissions to reach a peak in FY2019 (April 2018 – March 2019) conservation through development and wide use of highly Biodiversity
and then decline. water-saving products, and also through initiatives of cyclic The ecological system that supports and benefits our lives is By-Region
use of water in the course of manufacturing. based on a very fragile balance of diverse species. Once lost, Because every region has different circumstances and char-
Resources each species is gone forever, and it can never be recovered acteristics, Panasonic expands its Global Eco Project, which
Purchase of new materials can be reduced by effectively Chemicals by man. promotes products, production activities, and citizenship
using recycled materials throughout the business processes, Chemical substances are used in many products including We must therefore clearly recognize the impact of our busi- activities as specific initiatives tailored to each region.
from product design to procurement, production, distribu- familiar home appliances, making our lives more convenient. ness practices on biodiversity. At Panasonic, we focus on three Panasonic has formulated targets worldwide including the
tion, and recycling. With the two approaches of reducing the Meanwhile, hazardous substances have been detected in the areas - conserving green spaces at our business sites, pro- regions of Asia Pacific, Europe, China, North America, Latin
amount of waste generated from our operations and promot- far regions of the Arctic and Antarctic, having been carried curement of materials that have little impact on the environ- America, Russia, Middle East & Africa, and Taiwan.
ing the recycling of resources, Panasonic will continue to by the winds and ocean currents over a long period of time. ment, and developing products that contribute to biodiversity.

6 7
2
1 PRECAUTIONS FOR HANDLING VRLA BATTERIES PRECAUTIONS FOR HANDLING VRLA BATTERIES 1

This document should be read in its entirety and its contents fully understood before handling or using Panasonic recharge- 0°C to 40°C. Storage: -15°C to 40°C. Temperatures above The batteries tend to generate an inflammable gas upon
able sealed Lead-Acid batteries. If there are any questions, please contact Panasonic. Please keep this document available or below those recommended could result in damage or excess charge resulting in an explosion or fire if the room
for reference. Due to the potential energy stored in the batteries, improper handling or use of the batteries without under- deformity of the batteries. is closed.
standing this document may result in injury caused by electrolyte leakage, heat generation, or explosion. 2. Avoid placing batteries near a heat-generating device (such
as a transformer) which may cause the batteries to gener- Warning
ate excessive heat, leak or explode. 1. Do not contact any plastic or resin* which contains a
3. Do not allow the batteries to be exposed to rain or sea water. migrating plasticizer with the batteries. Furthermore,
DEGREE OF DANGER Note 3 If the battery terminals should get wet, they may corrode. avoid using organic solvents such as thinner, gasoline,
‘Requests’ are meant to prevent a decrease in the quality or 4. Do not use or store the batteries in a car under the blazing lamp oil, benzine and liquid detergent to clean the bat-
Danger the performance of the batteries. sun, in direct sunlight. To do so may cause the batteries to teries. The use of any of above materials may cause
When the batteries are handled or used improperly, death or leak, generate excessive heat, or explode. the containers and/or the covers (ABS resin) of the
severe injury may occur. ENVIRONMENT AND CONDITION 5. Do not use or store the batteries in a dusty place as dust batteries to crack and leak. This may cause a fire in the
may cause them to short circuit between their terminals. worst scenario. Make sure the use of material will not
Warning Danger When using the batteries in a dusty place, check them cause the containers and/or the covers of the batteries to
When the batteries are handled or used improperly, death or 1. Do not put the batteries into airtight containers or bags. The periodically. crack due to the migration of plasticizer within the material
severe injury may occur, and slight injury or loss of products batteries tend to generate inflammable gas upon excess 6. In applications requiring more than one battery, first by asking the manufacturer of the material if necessary.
often occur. charge which may cause an explosion if enclosed in an connect the batteries together and then connect the 2. Always use such as rubber gloves when handling batter-
airtight container. batteries to the charger or the load. Be careful to connect ies with the voltages higher than 45V in order to prevent
Caution the (+)pole of the batteries to the (+)terminal of either the severe bodily injury from occurring.
When the batteries are handled or used improperly, slight Warning charger or the load. Improperly connecting the batteries, 3. Do not install the batteries in areas where they may come
injury may occur and damage to the batteries and equipment 1. The batteries must be charged using the specified charger charger, or load may cause an explosion or fire to occur. In in contact with water. If the batteries come in contact with
may occur. or by maintaining the charging conditions indicated by some cases, bodily injury may occur. water, an electric shock may occur.
Panasonic. If the batteries are charged under conditions 7. When handling the batteries, wear steel-tipped shoes
Request other than those specified by Panasonic, they may leak, to prevent possible injury to the feet if the batteries are Caution
When the batteries are handled or used improperly, damage generate excessive heat, or explode. accidentally dropped. 1. During unpacking, handle the batteries carefully and check
to quality or performance may occur. 2. When using the batteries in medical equipment, incorpo- for cracks, breakage, or electrolyte leakage. Failure to handle
rate a back-up system other than the main battery in the Request carefully may result in damage due to physical shock.
Note 1 event of power failure. 1. Dropping a battery may cause a strong physical shock that
Improper handling and use of the batteries may cause dan- 3. Insert insulation that is resistant to heat and sulfuric acid may damage the performance of the battery.
gerous conditions to arise. All precautions should be taken between the batteries and any metallic housing. Failure to 2. Confirm the life of the batteries using the real load and na
Pa
so
to prevent any harmful effects from the use of the batteries. do so may cause the batteries to smoke or burn in case of charger. Differences in the charging and the discharging
nic
nic
electrolyte leakage. conditions may cause a big difference in the life of the Upside-down n aso
position Pa Upright
position
Note 2 4. Do not place the batteries near a device that may generate batteries.
‘Severe injury’ as a result of improper handling or use of the sparks (such as a switch or fuse) and do not place the
Horizontal

Pa n a s o n i c
INSTALLATION

c
position

ni
batteries may include but are not limited to loss of eyesight, batteries close to fire. The batteries may generate an

o
as n
Pa
injury/burn/electric shock/fracture of a bone/poisoning with inflammable gas when charged excessively that may ignite Vertical
position
after effect, or injury that requires long-term medical treat- upon contact with a spark or they may burn or explode due Danger
ment. ‘Slight injury’ covers such conditions as burns or electric to sparks or fire. 1. Tools such as wrenches used to install the batteries
shock that do not require long-term medical treatment. should be insulated. Bare metal tools may cause an ab-
Damage to products is defined as extensive damage to a house, Caution normal short circuit accident to occur resulting in bodily 2. When the batteries are being mounted in the equipment,
a house hold effects, a livestock, or pets. 1. Use or store the batteries in the temperature range: Dis- injury, damage to the batteries, explosion or fire. consider the best position for easy checking, maintenance
charge (operating in application): -15°C ~ 50°C. Charge: 2. Do not install the batteries in a room without ventilation. and replacement. In addition, the batteries should be

* Examples for plastic or resin which should be avoided using: vinyl chloride, oily rubber.
8 Examples for plastic or resin which is proper for the use: Polyolefin resin such as polypropylene, polyethylene. 9
1 PRECAUTIONS FOR HANDLING VRLA BATTERIES PRECAUTIONS FOR HANDLING VRLA BATTERIES 1

located in the lowest part of the equipment as possible. PREPARATION PRIOR TO OPERATION UNSPECIFIED USE physical shocks or jolts while moving them. Treating the
The rechargeable sealed Lead-Acid batteries, mentioned batteries roughly could cause leaks, heat generation, or
in this document, are designed for use in any position, but Danger Caution explosions.
charging the batteries in the upside-down position should 1. Be sure to provide enough insulation around the lead wires 1. Do not place the batteries in an unspecified use or they may 8. Do not charge the batteries beyond the amount of the time
be avoided. When these batteries are charged excessively and/or plates used between the batteries and the appli- leak, generate heat, or explode. indicated in the specifications, or do not charge after the
in the upside-down position, leakage of electrolyte from cation. Insufficient insulation may cause an electric shock. charge indication lamp indicates a full charge. Take the bat-
the rubber vents may occur. The upside-down is shown Heat generating from a short circuit (or excess current) METHOD OF HANDLING AND OPERATION teries off the charger if the charge is not finished after the
on the left side of the next drawings. In this upside-down may result in an injury, burn, smoke or fire. specified charge time. Over-charging can cause leakage,
position, the mark ‘Panasonic’ on the battery are turned Danger heat generation, or explosions.
upside down. The drawings are only for explanation of the Caution 1. Do not directly connect the positive and negative terminals 9. Children should be taught how to handle and use the bat-
battery’s position; therefore these are not equal to the real 1. Do not plug the batteries directly into the outlet or the with a conductive material such as a wire. Be careful while teries correctly.
appearance of the battery that the specifications describe. cigarette receptacle of a car without inserting a charger using a metal tool such as a wrench and/or carrying the 10. Keep the batteries out of the reach of small children at all
Can be used in the vertical position and the side­down po- between the batteries and the outlet or the receptacle. To batteries with metallic necklaces and hairpins not to make times.
sition (maximum angle of 90°C from the normal position). do so may cause electrolyte leakage, heat generation, or a short circuit. A short circuit of the battery’s terminals
3. Do not carry the batteries by picking up them by their explosion of the battery. may cause a heat generation, an explosion, or a fire. Request
terminals or lead wires. To do so may damage the batteries. 2. Turn off the circuit switch when the connections between 1. The cut-off voltage during discharge should vary depending
4. Be careful not to jolt the batteries as it may result in the batteries and the charger/load are made. Warning on the discharge current. Do not discharge the batteries
damage to them. 3. When using the batteries for the first time, check for rust, 1. Never dispose of the batteries in a fire as it may cause lower than the recommended cut-off voltage shown in
5. Be aware the batteries are relatively heavy compared to heat generation, or any other abnormalities. If found, do them to explode or generate a toxic gas. Panasonic specifications or Panasonic technical handbooks.
their volume. Please be careful to carry these batteries in not use as it may cause electrolyte leakage, heat genera- 2. Do not attempt to disassemble the batteries as it could Recharging a battery which was once discharged below the
order to avoid injury and/or lumbago. tion, or explosion. cause leakage of Sulfuric acid that could cause injury. recommended cut-off voltage may generate heat, resulting
6. Do not cover the batteries with plastic sheet as it may in the deformation of the battery or in condensation around
cause a fire or an explosion by conducting static electricity. Request Caution the battery cover caused when moisture within the battery
7. Fasten the bolts and the nuts with the torque as shown 1. Since the batteries tend to lose a part of their capacity due to 1. To prevent accidents from happening, change any battery evaporates. In addition, the efficiency of the battery would
below: Not to do so may cause the battery terminals to break. self-discharge during shipment and storage, recharge the that is found to have an abnormality such as a crack, a eventually decrease. Overdischarging a battery may result
batteries before you use them after purchase or long-term deformity, or leakage. The batteries must be kept clean in reduced performance. Always recharge the batteries
Bolt (nut) size (mm) Fastening torque
(Nm)
storage in order to restore their full capacity. Check for and free from dust to prevent loss of capacity or accident. immediately after discharge even if the batteries were
Diameter Pitch Length
M5 (5) 0.8 15 ± 1 2.0 – 3.1 the following conditions before to recharge: 2. If any abnormality of the charge voltage or the discharge not discharged to the recommended cut-off voltage. If the
M6 (6) 1.0 20 ± 1 4.1 – 5.6 voltage is detected replace the batteries with new ones. batteries are not charged soon after discharge, the batteries
M8 (8) 1.25 20 ± 1 8.2 – 10.2 Charging
method Charging condition (at 20°C) 3. Charging the batteries with an inverse polarity connection performance may be reduced due to the so-called ‘sulfation
M10 (10) 1.5 25 ± 1 14.7 – 19.7

Constant Regulation range of the controlled voltage: 7.25V to 7.45V/6V between the batteries and the charger could cause elec- phenomena’.
voltage battery, 14.5V to 14.9V/12V battery;
8. Place the necessary insulating covers over the terminals, initial current: 0.1CA to 0.4CA; trolyte leakage, heat generation, or a fire. Note: The cut-off device to prevent overdischarge should cut
maximum charging time: 24 hours.
the connecting bars, and bolts and nuts to prevent a dan- Short-time charge is possible when several batteries of the 4. Do not solder directly on the batteries’ terminal tabs. Sol- off all discharge current including any weak current.
same model, under the same storage conditions can be
gerous electric shock. charged in series. Otherwise they can be charged separately. dering directly on the batteries’ terminals may cause a 2. Thoroughly study the charge methods and the conditions
9. Please consult Panasonic prior to using the batteries in Constant Charging current: 0.1CA
leak of electrolyte. Consult Panasonic when soldering is of the batteries before adopting other charge methods
current Charging time (hours) = [Amount of self-discharge (Ah)/0.1CA]
applications such as a motor bicycle, an engine driven x 120% necessary. which are not shown in the Panasonic specifications or the
Rough estimation of amount of self-discharge is as follows
lawn mower, etc. which may generate severe vibration. (for an example): When the storage ambient temperature 5. Avoid the use of the batteries differing in capacity, type, Panasonic technical handbook, for safety reasons.
is lower than 20°C, and storage time is known, assume the
10. Fasten the batteries firmly to the equipment to avoid the following amount of self-discharge: history of use (charge/discharge operation). These differ- 3. When the batteries are used in a cyclic application, it is
[5%/month] x storage months
influence of vibration and/or physical shock. Multiply this by the rated capacity (at 20 hours rate) of the ences could cause electrolyte leakage or heat generation. important to charge the batteries for the proper amount
battery.
Regardless of the above calculation, the charge time for a refresh 6. Do not remove or scratch the outer tube of the battery or it of time. A timer should be incorporated into the charging
charge must be less than 12 hours.
Request When the storage ambient temperature is higher may cause an electrolyte leakage or electrical leakage. circuit that will disconnect the charging current to prevent
than 20°C, please consult Panasonic.
1. The batteries should be installed by a certified technician. 7. Do not allow the batteries to be subjected to any strong overcharging. Also, it is important to allow the battery to

10 11
1 PRECAUTIONS FOR HANDLING VRLA BATTERIES PRECAUTIONS FOR HANDLING VRLA BATTERIES 1

completely charge before removing the battery from the The expected life of the batteries (in trickle or float use) 2. Keep the batteries from rain water that could cause after charge. If the batteries are stored for more than a
charger. will decrease to half (50%) with each 10°C rise in corrosion on the terminals of the batteries. year at room temperature, the life of the batteries may be
4. Avoid parallel charging of the batteries in cycle use. This temperature above 20°C. In particular, the life of the 3. Keep the batteries right-side-up during transportation shortened.
may shorten the life of the batteries by causing an imbalance batteries will be shortened remarkably at approximately and do not give any abnormally strong shock and jolt to 2. Store the batteries starting from the fully charged state to
in the charge/discharge operation of the batteries. 40°C. Accordingly, precautions are required to prevent the the batteries. Transporting the batteries in an abnormal prevent the life of the batteries being shortened.
5. Measure the total voltage of the batteries during trickle use of batteries at high temperatures. position or handling them roughly could destroy the 3. Use the batteries as quickly as possible after receiving
charge (or float charge), using a voltage meter. If the total batteries or cause their characteristics to deteriorate. them as they gradually deteriorate even under proper
voltage of the batteries provide an indication deviating Caution 4. When storing the batteries, be sure to remove them from storage conditions.
from the specified voltage range, be sure to investigate 1. Avoid using organic solvents such as thinner, gasoline, lamp the equipment or disconnect them from the charger and
the cause. If the total voltage is lower than that specified, oil, or benzine, and liquid detergent to clean the batteries. the load, then store them at room temperature or lower DISPOSAL AND RECYCLING
the batteries may lose their capacity because of a lack of These substances may cause the battery containers temperature. Do not store the batteries at direct sun-
sufficient charge. However, if the total voltage is higher to crack or leak. light, higher temperature or high humidity. To do so cause Caution
than that specified, the batteries may lose their capacity the batteries short life, performance deterioration or 1. Please write the information about battery recycling on
by damage due to overcharge and may suffer from ‘thermal Request corrosion on terminals. the equipment, the package, the carton, the instruction
runaway’ and other accidents. 1. Keep the battery terminals clean in order to avoid inter­- manual etc. in countries where legal or voluntary regula-
6. Switch off the equipment after use to prevent loss of ruption in the discharge and/or to maintain the charge. Request tions on battery recycling are applicable.
performance or shortened life of the batteries due to 1. Charge the batteries at least once every twelve months 2. Design the equipment such that exchange and disposal of
damage overdischarge. TREATMENT AT EMERGENCY if they are stored at 20°C. Use the charge method speci- the batteries can be undertaken easily.
7. When storing the batteries, be sure to remove them from fied in ‘4. Charging methods’. The interval of this charge 3. Used batteries should be recycled. When returning used
the equipment or disconnect them from the charger and Warning should be reduced to 50% by each 10°C rise in tempera- batteries, insulate their terminals using adhesive tape,
the load to prevent overdischarge and loss of capacity. 1. The batteries have toxic liquid – dilute sulfuric acid solution ture above 20°C. The self-discharge rate doubles for each etc. Even used batteries still have electrical charge and
Before storing batteries, charge the batteries fully. Do in them. If the acid comes into contact with skin or clothes, 10°C in temperature. If they are stored for a long time in an explosion or a fire may occur, if proper insulation is not
not store batteries in a highly humid place to prevent rust wash skin or cloth with lots of clean water to prevent a discharged state, their capacity may not recover even given on the terminals of the used batteries.
from forming on the terminals. scalding from occurring. If the acid should come into
contact with the eyes, wash the eyes with lots of clean
MAINTENANCE water and consult a physician immediately to prevent GENERAL INFORMATION 2
possible loss of sight.
Warning
Fig. 1 Magnification of positive active material
1. When cleaning the batteries, use a soft damp cloth. Caution BATTERY CONSTRUCTION
A dry cloth may cause static electricity which could result 1. Check the batteries visually for any sign of irregularities in
in a fire or explosion. appearance. If any damage exists such as cracks, deforma- Positive plates
2. Replace batteries with the new ones before the end of tion, leakage of electrolyte, or corrosion, the batteries must Positive plates are plate electrodes of which a grid frame
their useful life as determined in the specifications. When be replaced with the new ones. Irregularities in the batteries of Lead-Tin-Calcium Alloy holds porous lead dioxide as the
the batteries near the end of their life (50% state of their could result in bodily injury, electrolyte leakage, excessive active material. The magnification of a positive active material
initial discharge duration time) the remaining life will heat generation, or explosion, if used. Furthermore, make is shown on following figure 1.
shorten remarkably. Finally the batteries will lose their sure the batteries are clean and free from dirt and dust.
available capacity by either drying out their electrolyte Negative plates
(causing increase in their impedance) or an internal STORAGE Negative plates are plate electrodes of which a grid frame
short-circuit. In such case, if the batteries go on charging, of Lead-Tin-Calcium Alloy holds spongy Lead as the active
thermal runaway and/or leakage of electrolyte may occur. Caution material. The magnification of a negative active material is
The batteries should be replaced before reaching these 1. Store the batteries in a fixed position separate from metal shown on following figure 2.
conditions. or other conductive materials.

12 13
2 GENERAL INFORMATION GENERAL INFORMATION 2

Fig. 2 Magnification of negative active material charger malfunctions or other abnormalities, the vent Valve Fig. 5 Battery case materials (example LC-R series) In the final stage of charging, an oxygen-generating reaction
opens to release excessive pressure in the battery and main- occurs at the positive plates. This oxygen transfers inside the
tain the gas pressure within specific range (7.1 to 43.6kPa). battery, then is absorbed into the surface of the negative plates
During ordinary use of the battery, the vent valve is closed to and consumed. These electrochemical reaction processes are
shut out outside air and prevent oxygen in the air from react- expressed as follows.
ing with the active material in the negative electrodes.
APPLICATIONS
Positive and negative electrode terminals
Positive and negative electrode terminals may be faston tab Stand-by/Back-up power applications
type, bolt fastening type or threaded post type, depending on C
 ommunication equipment: base station, PBX, CATV, WLL,

the type of the battery. Sealing of the terminal is achieved by ONU, STB, etc.
a structure which secures long adhesive-embedded paths B
 ack-up for power failure: UPS, ECR, computer system
Electrolyte and by the adoption of strong epoxy adhesives. For specific back-up, sequencers, etc.
Diluted Sulfuric Acid is used as the medium for conducting dimensions and shapes of terminals, see page 25. ELECTROCHEMICAL REACTIONS ON E
 nergy saving: solar and/or wind powered lanterns, wind

ions in the electrochemical reaction in the battery. Some ELECTRODES powered advertising displays, etc.
additives are included to keep good recovery performance Battery case materials and the design E
 mergency equipment: lights, fire and burglar alarms,

after deep discharge. Materials of the body and cover of the battery case are ABS res- The electrochemical reaction processes of the sealed Lead-Acid radios, fire shutters, stop-position controls (for machines
ins, unless otherwise specified. Since the inside of VRLA battery battery (negative electrode recombination type) are described and elevators), etc.
Separators is pressurized and depressurized, stress occurs at the contain- below. Where ‘charge’ is the operation of supplying the recharge-
Separators, which retain electrolyte and prevent shorting be- er and cover. The design according to the stress is designed to able battery with direct current from an external power source Main power applications
tween positive and negative plates, adopt a non-woven fabric of accommodate the fluctuations in stress in the event the battery to change the active material in the negative plates chemically, Electrically operated vehicles: picking carts, automated
fine glass fibers which is chemically stable in the diluted sulfu- becomes deformed. The thickness of container, form, material and hence to store in the battery electric energy in the form of transports, electric wheelchairs, cleaning robots, electric
ric acid electrolyte. Being highly porous, separators retain elec- and stress analysis are determined by utilization of computer chemical energy. ‘Discharge’ is the operation of drawing out automobiles, electric lawnmovers, etc.
trolyte for the reaction of active materials in the plates. Typical aided engineering (CAE). This depicts the container design & electric energy from the battery to operate external equipment. Tools and engine starters: grass shears, hedge trimmers,
magnification of separator is shown in following figure 3. strength. Destructive examinations using the molded container scooters, jet-skis, electric saws, etc.
are also carried out. In other cases in which water in electrolyte
Fig. 6 Charge / discharge chemical equation
Fig. 3 Typical magnification of separator liquid may penetrate through container in service life, the con-
tainer design is put through water penetration tests. (Positive electrode) (Negative electrode) (Electrolyte) (Positive electrode) (Negative electrode) (Electrolyte)
Discharge
Fig. 4 CAD container design PbO 2 + Pb + 2H 2 SO 4 PbSO 4 + PbSO 4 + 2H 2 O
Charge
( Le a d d iox id e ) ( Le a d ) ( S ulfuric a c id ) ( Le a d sulfa te ) (Lead sulfate) ( W a te r)

Fig. 7 Recombination chemical equation

Charge Overcharge
(Positive electrode) PbSO 4 PbO 2 O2

(Lead sulfate) (Lead dioxide) (Oxygen)


Charge
(Negative electrode) PbSO 4 Pb(O 2)
Vent (one way valve)
(Lead sulfate) (Lead)
The Valve is comprised of a one-way Valve made of material
Reaction
such as Neoprene. When gas is generated in the battery un-
Gas recombination reaction cycle
der extreme overcharge condition due to erroneous charging,

14 15
2 GENERAL INFORMATION CHARACTERISTICS 3

Industrial equipment/instruments and non life-critical mately double that of the conventional (LC-R and LC-L series) smaller discharge currents, the active materials in the bat- or reduction in the number of times of repeatable discharge.
medi­cal equipment* : measuring equipment, non life-
1
batteries (temperature 20°C), discharge rate 0.25CA/1.75V/ tery work effectively, therefore discharge cut-off voltages are When discharging the battery beyond said range, please
criti­cal medical equipment (electrocardio-graph), etc. cell, discharge frequency every 6 months, 2.30V/cell charge). set to the higher side for controlling overdischarge. For larger consult Panasonic in advance.
P
 hotography: camera strobes, VTR/VCR, movie lights, etc. discharge currents, on the contrary, cut-off voltages are set
T
 oys and hobby: radio-controllers, motor drives, lights, etc. Easy maintenance to the lower side. Note: Discharge cut-off voltages given are Fig. 3 Discharge capacity by temperature and by discharge
Miscellaneous uses: integrated VTR/VCR, tape recorders, Unlike conventional batteries in which electrolyte can flow recommended values. current
other portable equipment, etc. freely, VRLA batteries do not need the specific-gravity check
120
of the electrolyte or the water top up maintenance, this al- Fig. 2 Discharge current vs. cut-off voltage
0.05CA
FEATURES lows the battery to function fully with the minimum of main- 100 0.1CA

Discharge cut-off voltage (12V battery)


5.4 10.8

Discharge cut-off voltage (6V battery)


tenance.
5.2 10.4 0.25CA
80
Leak-resistant structure

Capacity (%)
5.0 10.0
A required-minimum quantity of electrolyte is impregnated No Sulfuric acid mist or gases 60
1CA
4.8 9.6
into, and retained by, the positive and negative plates and the Unlike conventional batteries in which electrolyte can flow
4.6 9.2
separators; therefore electrolyte does not flow freely. Also, freely, VRLA batteries generate no Sulphuric acid mist or 4.4 8.8
40

the terminal has a sealed structure secured by long adhesive- gases under Panasonic recommended use conditions. 4.2 8.4
20
embedded paths and by the adoption of strong epoxy adhe- If used under conditions other than recommended then gas 4.0 8.0

sives which makes the battery leak-resistant. Note: In stand- generation may occur, therefore do not design the battery 0.05 0.1 0.2 0.3 0.5 1 2 3 0
Discharge current (CA) -20 -10 0 10 20 30 40 50
by/back-up uses, if the battery continues to be used beyond housing in a closed structure. Temperature <˚C>
the point where discharge duration has decreased to 50% of
the initial (i.e. life judgment criteria), cracking of the battery Exceptional deep discharge recovery Discharge temperature
case may occur, resulting in leakage of the electrolyte. Our VRLA batteries show exceptional rechargeablity even after Control the ambient temperature during discharge within the Depth of discharge
deep discharge, which is often caused by failure to turn off the range from -15°C to 50°C for the reason described below. Depth of discharge is the state of discharge expressed by the
Long service life equipment switch, followed by standing (approx. 1 month at Batteries operate on electrochemical reaction which converts ratio of amount of capacity discharged to the rated capacity.
Service life of our long-life series (LC-P, LC-X series) is approxi­ room temperature is assumed). chemical energy to electric energy. The electrochemical re-
action is reduced as the temperature lowers, thus, available STORAGE
discharge capacity is greatly reduced at temperatures as low
3 CHARACTERISTICS as -15°C. For the high temperature side, on the other hand, Storage condition
the discharge temperature should not exceed 50°C in order to Observe the following condition when the battery needs to be
prevent deformation of resin materials which house the bat- stored.
Fig. 1 Constant-voltage charge characteristics by current
CHARGING tery or deterioration of service life.
(example)
1. Ambient temperature: -15°C to 40°C (preferably below 30°C)
Charge characteristics (constant voltage-constant current (V/cell) 2.5 Effect of temperature on discharge characteristics 2. Relative humidity: 25 to 85%
Voltage

charging) of VRLA batteries are exemplified in the figure 1. Available discharge capacity of the battery varies with ambient 3. Storage place free from vibration, dust, direct sunlight,
In order to fully utilize the characteristics of VRLA batteries, 2.0 temperature and discharge current as shown in the figure 3. and moisture.
constant-voltage charging is recommended. For details of ~ (Test condition) ~
~
Discharge : 0.05 CA constant-
current discharge
0.4
charging see pages 20 – 24. Cut-off voltage; 1.75 V/cell
Charge : 2.45 V/cell Discharge current Self-discharge and refresh charge
2.30 V/cell
0.3 Temperature : 20˚C
Discharge capability of batteries is expressed by the 20 hour During storage, batteries gradually lose their capacity due to
Current

DISCHARGING 0.2
rate (rated capacity). Select the battery for specific equipment self-discharge, therefore the capacity after storage is lower
so that the discharge current during use of the equipment than the initial capacity. For the recovery of capacity, repeat
0.1
Discharge current and discharge cut-off voltage falls within the range between 1/20 of the 20 hour rate val- charge/discharge several times for the battery in cycle use;
(CA) 0
Recommended cut-off voltages for 6V and 12V batteries 0 3 6 9 12 15 18 ue and 3 times that (1/20CA to 3CA): discharging beyond this for the battery in trickle use, continue charging the battery as
Charge time (hours)
consistent with discharge rates are given in the figure 2. With range may result in a marked decrease of discharge capacity loaded in the equipment for 48 to 72 hours.

16 *1 When any medical equipment incorporating a Panasonic VRLA battery is planned, please contact Panasonic. 17
3 CHARACTERISTICS CHARACTERISTICS 3

Refresh charge (auxiliary charge) Open circuit voltage vs. residual capacity BATTERY LIFE Fig. 9 Cycle life vs. depth of discharge (cyclic models)
When it is unavoidable to store the battery for 3 months or Residual capacity of the battery can be roughly estimated by
1,500
longer, periodically recharge the battery at the intervals measuring the open circuit voltage as shown in the figure 5. Cycle life
recommended in the table below depending on ambient tem- Cycle life (number of cycles) of the battery is dependent on the
perature. Avoid storing the battery for more than 12 months. IMPEDANCE depth of discharge in each cycle. The deeper the discharge is, 1,000

the shorter the cycle life (smaller number of cycles), providing

Cycle life
Storage temperature Interval of auxiliary charge (refresh charge)
The impedance is an important parameter of batteries. the same discharge current. The cycle life (number of cycles)
Below 20°C 12 months
500
20°C to 30°C 9 months Impe­dance varies with the state of charge of the battery and of the battery is also related to such factors as the type of the
15
20°C to 40°C 6 months
temperature as shown on the chart below. battery, charge method, ambient temperature, and rest period
10
between charge and discharge. Typical cycle life characteristics 0
0 10 20 30 40 50 60 70 80 90 100 110
Residual capacity after storage Fig. 6 Relationship between impedance and state of charge of the battery by different charge/discharge conditions are Depth of discharge (%) Typical data (not guaranteed)
6
The result of testing the residual capacity of the battery which, shown by the below figures. This data is typical and tested at
Trickle long-life series
300 3
after fully charged, has been left standing in the open-circuit a well-equipped laboratory. Cycle times are different for each
280

Service life (years)


state for a specific period at a specific ambient temperature 260 battery model. Cycle times are also different from this data Fig. 10 Influence of temperature on trickle life
300
240
is shown in the figure below. The self-discharge rate is very 280 when using batteries under real conditions.
220
(%)

260 1 15
much dependent on the ambient temperature of storage. The 200
240
Impedance

Conventional products
180
higher the ambient temperature, the less the residual capacity 220 Trickle (float) life 10
(%)

160 0.5
200
after storage for a specific period. Self-discharge rate almost 140 Trickle life of the battery is largely dependent on the tempera-
Impedance

180
120
doubles by each 10°C rise of storage temperature figure 4. 160 ture condition of the equipment in which the battery is used,
100 6
140
80 and also relatedTest
to condition
the type of the battery, charge voltage and
120 Discharge: 0.25CA, end voltage: 1.7V/2V Trickle long-life series
0 20 40 60 80 100 Charging: 2.275V/2V, Constant-voltage control,
Fig. 4 Residual capacity test result 100 discharge current. The0.15CA
Current: respective figures show the influence 3
State of charge (% in C20)
80

Service life (years)


0.1
100 0 20 40 60 80 100
of temperature
10 on 20
trickle 30life of40the battery,
50 an example
60 70 of
State of charge (% in C20) trickle (float) life characteristics
Temperatureof(˚C)
the battery, and the test
80
Fig. 7180
Relationship between impedance and state of charge result of the battery life in an emergency lamp. 1
Residual capacity(%)

60
160 Conventional products
40°C 30°C 20°C 180
40 Fig. 8 Trickle life characteristics at 50°
140 0.5
(%)

160
Impedance

20 120 300
Test condition
140
(%)

Discharge: 0.25CA

Duration of discharge (minutes)


0 100 Cut-off voltage: 1.7V/2V
0 3 6 9 12 15 18 250 Charge: 2.275V/2V
Impedance

120 Test condition


Storage time (months) Constant-voltage control: 0.2CA Discharge: 0.25CA, end voltage: 1.7V/2V
80 Discharge frequency: once every 21 days
Charging: 2.275V/2V, Constant-voltage control,
100 200 Current: 0.15CA
60 0.1
80 -20 0 20 40 60 150
Fig. 5 Open circuit voltage vs. residual capacity 20°C 10 20 30 40 50 60 70
State of charge (% in C20)
60 Temperature (˚C)
100
7.00
(Temperature: 20˚C)
14.0
-20 0 20 40 60 Conventional Trickle long-
products life series
State of charge (% in C20)
6.75 13.5 50
Open circuit voltage (12V battery)
Open circuit voltage (6V battery)

6.50 13.0
0
0 2 4 6 8 10 12 14 16
6.25 12.5 50˚C discharge period (months)
TEMPERATURE CONDITIONS
6.00 12.0
0 3 6 9 10 12
300
Test condition
5.75 11.5 Conversion to 20˚C and EUROBAT conditions period (years)
Recommended temperature ranges for charging, discharging Discharge: 0.25CA

Duration of discharge (minutes)


Cut-off voltage: 1.7V/2V
5.50 11.0 250 Charge: 2.275V/2V
and storing the battery are tabulated below. Constant-voltage control: 0.2CA
5.25 10.5 Discharge frequency: once every 21 days
Charge 0°C ~ 40°C 200
5.00 10.0
0 20 40 60 80 100 Discharge -15°C ~ 50°C
Residual capacity (%)
Storage -15°C ~ 40°C 150

100
Conventional Trickle long-
18 products life series 19
50
4 CHARGING METHODS CHARGING METHODS 4

METHODS OF CHARGING THE VALVE REGULATED LEAD-ACID BATTERY For charging the valve regulated lead-acid cured. Typical methods to control charging so as to satisfy load in case the AC input is disrupted (such as a power failure).
battery, a wellmatched charger should be used because the capacity and life of the battery is influenced by ambient tem- the above requirements follow. There are two methods of charging for this use.
perature, charge voltage and other parameters. Charging methods are dependent on battery applications and are roughly
classified into main power applications and stand-by/back-up power applications. Two-step constant voltage charge control method a Trickle charging (compensating charging)
Two-step constant voltage charge control method uses two In this charge system, the battery is disconnected from the
constant-voltage devices. At the initial stage, the battery is load and kept charged with a small current only for compen-
charged by the first constant-voltage device SW(1) of high set- sating self-discharge while AC power is alive. In case of power
Main power source a Standard charging (normal charging)
up voltage (set-up for cycle charge voltage). When the charge failure, the battery is automatically connected to the load and
(cycle use) b Rapid charging
Classification current has reduced to the preset value, the device is switched battery power is supplied. This system is applied mainly as a
by application a Trickle charging (compensating charging)
Stand-by power source over to the second SW(2) of low set-up voltage (set-up for spare power source for emergency equipment. In this use, if
(trickle use) b Float charging
trickle charge voltage). This method has the advantage that rapid recovery of the battery after discharge is required, it is
the battery in trickle use can be charged in a comparatively necessary to consider the recovery charge with a compara-

Main power source (cycle use) at 0.4CA and controlling the voltage at 2.45V/per cell at a room short time for the next discharge. tively large current followed by trickle charge, or alternative
Cycle use is to use the battery by repeated charging and dis- temperature of 20°C to 25°C. Proper charging time is 6 to 12 measures. While the type and capacity of the battery is deter-
charging. hours depending on depth of discharge. Fig. 2 Charging characteristics of the two-step constant vol- mined by the back-up time and the load (current consumption)
tage control charger during power failure, some reserve power should be taken into

a Standard charging (normal charging) Fig. 1 Constant voltage constant-current charge characteristics account considering such factors as ambient temperature,
For common applications of the battery, the constant voltage Charge current Battery voltage capability of the charger and depth of discharge.

Battery voltage / Charge current


Charge voltage and charge current

charge method is advantageous as it allows the battery to


exert full performance. Fig. 4 Trickle charge system model
Charge voltage
~
~ Charge current
Constant voltage charging method Rectifier Load

This method is to charge the battery by applying a constant AC

voltage between the terminals. When the battery is charged


0 1 2 3 4 5 6 Power
Battery
by applying a voltage of 2.45V per cell (unit battery) at a room Time (hours) Charging time detection
relay
temperature of 20°C to 25°C, charging is complete when the
charge current continues to be stable for three hours. Valve
regulated lead-acid batteries can be overcharged without b Rapid charging Fig. 3 Diagram of the two-step constant voltage control charger
constant voltage control. When the battery is overcharged, When rapidly charging the battery, a large charge current is b Float charging
the water in the electrolyte is decomposed by electrolysis required in a short time for replenishing the energy which Current Float system is the system in which the battery and the load
detection
circuit
to generate more oxygen gas than what can be absorbed by has been discharged. Therefore, some adequate measures are connected in parallel to the rectifier, which should supply
the negative electrode. The electrolyte is changed to oxygen such as the control of charge current is required to prevent a constant power.

Charging
Voltage Voltage
AC Battery
gas and hydrogen gas, and lost from the battery system. As overcharging when the rapid charging is complete. Basic

supply
switch switch

power
input SW(1) SW(2)

the quantity of electrolyte is reduced, the chemical reactions requirements for rapid charging are as follows: Fig. 5 Float charge system model
of charge and discharge become inefficient and hence the
AC I0 IL
battery performance is severely deteriorated. Therefore, Sufficient charging should be made in a short time for fully SCR

exact voltage control and proper charging time in constant replenishing the amount discharged.
IC
voltage charging are essential for securing the expected life Charge current should be automatically controlled to

Rectifier

Load
of the battery. avoid overcharge even on prolonged charging. Stand-by/Back-up use (trickle use)
The battery should be charged adequately in the ambient The application load is supplied with power from AC sources
Constant voltage and constant-current charging method temperature range of 0°C to 40°C. in normal state. Stand-by/back-up use is to maintain the
This method is to charge the battery by controlling the current Reasonable cycle life of charge/discharge should be se- battery system at all times so that it can supply power to the

20 21
4 CHARGING METHODS CHARGING METHODS 4

In the above-illustrated model, output current of the rectifier 2. Relation between standard voltage value in constant volt- Fig. 7 Compensated voltage value Overcharging
is expressed as: lo = lc + lL where lc is charge current and lL age charging and temperature is given in the table. 2.7
Overcharge is an additional charge after the battery is fully
is load current. Consideration should be given to secure ad- charged. Continued overcharging shortens the battery life.
2.6
equate charging because, in fact, load current is not constant Fig. 6 Relation between standard voltage value in constant Select a charge method which is specified or approved for

Charge voltage/cell
but irregular in most cases. voltage charging and temperature 2.5 Cy each application.
cle
us
e Maximum
0°C 20°C 40°C Minimum voltage
voltage
6V 7.7 7.4 7.1 2.4
In the float system, capacity of the constant-voltage power Cycle use Charging before use
Maximum
12V 15.4 14.7 14.2 voltage
source should be more than sufficient against the load. Usu- 6V 7.1 6.8 6.7 2.3
Tr ic
k le u Recharge the battery before use to compensate for capacity
se
Trickle use
ally, the rectifier capacity is set at the sum of the normal load 12V 14.1 13.7 13.4 Minimum
voltage
loss due to self-discharge during storage. See ‘Refresh
2.2
current plus the current needed in order to charge the battery. -20 -10 0 10 20 30 40 50 charge (auxiliary charge)’ table on page 18.
Temperature (˚C)
Temperature compensation of charge voltage
Precautions on charging Charge voltage should be compensated to the ambient tem- Characteristics of constant voltage chargers
1. As the battery continues to be charged over a long period, a perature near the battery, as shown by the figure below. Main Charging time Even with the same voltage set-up, charging time varies with
small difference in charging voltage may result in a signifi- reasons for the temperature compensation of charge voltage Time required to complete charging depends on factors such output V-l characteristics.
cant difference in the battery life. Therefore, charge voltage are to prevent the thermal runaway of the battery when it is as depth of discharge of the battery, characteristics of the
should be controlled within a narrow range and with little used in high temperature conditions and to secure sufficient charger and ambient temperature. For cycle charge, charging Fig. 8 Output V-l characteristics of the constant voltage charger
variation for a long period. charging of the battery when it is used in low temperature time can be estimated as follows: vs. charging pattern of the battery
2. As charge characteristics of the battery are dependent on conditions. Prolongation of service life of the battery by the
V
temperature, compensation for temperature variation is above-described temperature compensation is expected as 1. when charge current is 0.25CA or greater:
required when the battery is used over a broad tempera- follows: Tch = Cdis / I + (3h to 5h)
ture range, and the system should be designed so that the 2. when charge current is below 0.25CA:

V
battery and the charger are kept at the same temperature. At 30°C: prolonged by approx. 5% Tch = Cdis / I + (6h to 10h), where
I
At 35°C: prolonged by approx. 10% Tch: Charging time required (hours) Time
I
Precautions on charging At 40°C: prolonged by approx. 15% Cdis: Amount of discharge before this charging (Ah) V

1. (a) in constant voltage charging (cycle use): Initial current I: Initial charge current (A)
should be 0.4CA or smaller (C: rated capacity) In low temperature zones below 20°C, no substantial prolon-
(b) in constant voltage charging (trickle use): Initial current gation of the battery life can be expected by the temperature Time required for trickle charge ranges from 24 to 48 hours.

V
should be 0.15CA or smaller (C: rated capacity). compensation of charge voltage. I

Charging temperature Time


I

1. Charge the battery at an ambient temperature in the range


V
CHARGING METHODS AND APPLICATIONS OF VRLA BATTERIES from 0°C to 40°C.
2. Optimum temperature range for charging is 5°C to 35°C.
Application /charging method Normal charging in 6 or more hours; constant voltage control Two-step constant voltage control Constant current control 3. Charging at 0°C or below and 40°C or higher is not rec-

V
Control voltage: 7.25 to 7.45V/6V battery ommended: at low temperatures, the battery may not be­
Cycle Use 14.5 to 14.9V/12V battery I
Initial current: 0.4 CA or smaller charged adequately; at high temperatures, the battery
I Time
Initial charging with current of may become deformed. V
Control voltage: 6.8 to 6.9/6V battery
Trickle use approx. 0.15CA, followed by
13.6 to 13.8V/12V battery
switching voltage to trickle charge 4. For temperature compensation values, see ‘Temperature

Control voltage: 6.8 to 6.9/6V battery; 13.6 to 13.8V/12V compensation of charge voltage’ on page 22.
Float use
battery. Float charging compensates for load fluctuations.

V
Refresh charge When charging two or more batteries at a time, select only Charging with current
(auxiliary charge)*1 those which have been left under the same condition. of approx. 0.1CA Reverse charging I

General uses, cellular phones (bag phones), UPS, Medical equipment, Never charge the battery in reverse, as it may cause leakage,
Application example I Time
lanterns, electric tools personal radios
heating or bursting of the battery.

22 *1 Refresh (auxiliary) charge amount should be 120 to 130% of self-discharge amount. For details, please contact us. 23
4 CHARGING METHODS TERMINAL DATA 5

Fig. 9 Example of constant voltage charger circuitry (concept diagram) Bolt and nut type
L-shape terminal (M5, M6, M8)
R 5.6K
1/4W

Q A A
(1) (2) (3)
D B1 E3
1A E1 F1
D E3 B2
200V
1.2V
E2
R56 F2
LED R
1/4W 2.2K
R
1/4W
R 1K
R
Q 1/4W
A.C. 33K 1.2K
100V 1/4W 1/4W
C
C Q 25V
50V 47uF
Q C
470uF
50V VR 500 Height from
R 10,000PF 0.1W Hole position Bolt
TR battery case top
D D 5.6K Terminal
0.8A R56 Type of Terminal Hole
2A 1/4W thickness
2A 1/4W terminal width diameter Distance Distance Distance from
15.5V D A (1) Diameter Length
B1 (1) B2 (2) from top from top terminal top Pitch
Q ZD R F1 (3) F2 (3)
E1 (1) E2 (2) E3 (2)
1.2 5V 1K
R1/4W 500W 1/4W M5 bolt and nut 5.0 ± 0.3 1.0 – 11 ± 0.4 5.5 ± 0.3 6.5 – 5.5 ± 0.3 M5 P = 0.8 15 ± 1.0
M6 bolt and nut 8.0 ± 0.5 5.0 16.5 ± 1.5 16 ± 0.8 6.5 ± 0.4 – 9 ± 1.0 7.5 ± 0.4 M6 P = 1.0 20 ± 1.0
M8 bolt and nut 8.0 ± 0.5 – 24 ± 1.5 – 6.5 ± 0.4 – 14 ± 1.0 10 ± 0.4 M8 P = 1.25 20 ± 1.0

Precautions 6. In cyclic service of the battery, avoid charging two or more Terminal material
1. When adopting charging methods and charging con- batteries connected in parallel simultaneously: imbalance Bolt & nut: Lead Alloy T-shape terminal (M10)
ditions other than those described in the specifications of charge/discharge amount among the batteries may
or the brochures, thoroughly check charging/discharging shorten the life of batteries. (Proposition 65 Warning: Battery posts, terminals and related accessories contain
characteristics and life characteristics of the battery in lead and lead compounds, and handling this product may also expose you to
advance. Selection of appropriate methods and conditions Sulfuric acid mist, chemicals known to the State of California to cause cancer and
of charging is essential for safe use of the battery and for reproductive harm. Wash hands after handling.)
fully utilizing its discharge characteristics.
2. In cyclic use of the battery, use a charger equipped with Fasten 187: Tin plated brass
a charging timer or a charger in which charging time or Fasten 250: Tin plated brass
charge amount is controlled by other means; otherwise, Threaded: Tin plated steel
it will be difficult to judge the completion of the charge.
Use of a charger as described above is recommended
Faston tab type 187 Faston tab type 250 M5 threaded post type
to prevent undercharge or overcharge which may cause
deterioration of the battery characteristics. 0.187 (4.75) 0.25 (6.35) M5-bolt
P = 0.031 (0.8)
3. Continue charging the battery for the specified time or

0.386
(4.52)
0.178

(9.8)
0.25 (6.35)
until the charge completion lamp, if equipped, indicates

0.126
completion of charging. Interruption of charging may
cause a shortening of service life. (3.2)

4. Do not recharge the fully charged battery repeatedly, as


overcharge may accelerate deterioration of the battery. 0.031 0.031
(0.8) (0.8)
5. In cyclic use of the battery, do not continue charging for 24
hours or longer, as it may accelerate deterioration of the
battery. Unit: inch (mm)

24 25
6 SAFETY SAFETY DESIGN 7

VRLA battery safety test items even a fire. And the grid growth may cause internal short Fig. 3 Cast grid and expanded grid
Item Test method Check point between positive grid and negative strap in a cell. Continuing
1. Shock test (drop test) A fully charged battery is allowed to drop in the upright The battery should bee free from noticeable breakage or to charge a string of cells when one or more of the cells Cast grid
IEC 61056-1 and JIS C 8702 (These spe- position from the height of 20cm onto a hard board having a leaks; and its terminal voltage should be held higher than the
cifications are harmonized each other) thickness of 10mm or more. Test is repeated three times. nominal voltage. exhibit internal shorts, can result in thermal runaway. For
example, assume a string of 12 cells is being charged at
2. Vibration test A vibration frequency 1,000 times/minute and amplitude 4mm No battery part should be broken; the battery should be free
IEC 61056-1 and JIS C 8702 (These spe- (equals 2.2g of force) is applied to the X-, Y- and Z-axis direc- from leaks; and its terminal voltage should be held higher
cifications are harmonized each other) tions of a fully charged battery for 60 minutes respectively. than the nominal voltage.
27.3V (2.275V/cell) and the string continues in operation with
two cells shorted. In this situation the average charging
3. Oven test A fully charged battery is left standing in an atmosphere of The battery case should not be deformed;
Panasonic internal standard 70°C for 10 hours. the battery should be free from leaks. voltage on the remaining 10 good cells is 2.73V/cell. This will
Grid expansion
result in very high float current and cause thermal runaway. is limited
4. Coldproof test A fully charged battery is connected to a resistor equivalent to No crack should develop in the battery case;
Panasonic internal standard 60 hour rate discharge and left for 4 days; than the battery is the battery should be free from leaks. Figure 2 is the mechanism of above phenomena.
left standing in an atmosphere of -30°C for 24 hours.
Panasonic VRLA battery minimizes these risks by using less
5. Heat cycle test A fully charged battery is exposed to 10 cycles of 2 hours at No crack should develop in the battery case;
Panasonic internal standard -40°C and 2 hours at 65°C. the battery should be free from leaks. corrosive lead alloy and expanded positive grid. Figure 3
Expanded grid
shows an example of cast grid and expanded grid. Expanded
6. Short circuit test A fully charged battery connected with a small The battery must not burn nor bust.
Panasonic internal standard resistor of 10 ohms or less is allowed to discharge. grid does not have enough strength to crack container case

7. Large current discharge test A fully charged battery is allowed to discharge at The battery should not burn or bust, and it should be free
by grid growth. And an insulator between positive grid and
Panasonic internal standard 3CA to 4.8V/6V battery level. (This test is not applicable to from battery case deformation, leaks and any irregularity
batteries having built-in thermostat.) internal connections. negative strap is installed in the models as necessary.
Furthermore, Panasonic uses flame retardant battery con-
8. Vent valve function test A fully charged battery is submerged in liquid paraffin in a Release of gas from the vent should be observed.
UL1998 container, then overcharged at 0.4CA. (UL1989) tainer case for the models used for stand-by application. The
cases are designed to be self-extinguishing and meet minimum 1. Safety & reliability (improved)
9. Overcharge test A fully charged battery is overcharged at 0.1CA for 48 hours, No irregularity should be noticed in the battery appearance;
Panasonic internal standard left standing for one hour, and allowed to discharge at the battery should retain 95% or more of the initial capacity. 2. Corrosion resistance (improved)
0.05CA to 5.25V/6V.
flammability standards of UL94 V-0 and 28 L.O.I. (Limiting
3. Small discharge dispersion
Oxygen Index). Figure 4 is the picture of self-extinguishing
phenomenon.

7 SAFETY DESIGN
Fig. 2 Mechanism of thermal runaway caused by grid growth Fig. 4 Flame retardant case (self-extinguish phenomenon)

Vent (one way valve) VRLA batteries are inherently safe. However, there are some Internal short circuit Container case crack Standard ABS Flame retardant ABS Burnt
(UL94 HB) (UL94 V-0)
If the internal pressure of the battery is raised to an abnormal risks when VRLAs are used beyond a reasonable replacement
Expansion of strap strap Expansion of
level, the rubber one way valve opens to release excessive time span, misapplied or abused. There are two main failure positive grid positive grid
pressure; thus the valve protects the battery from danger of mode of VRLA battery used for trickle (float) application. In
bursting. Since the rubber valve is instantly resealable, the high temperatures and/or high voltage charging, dry-out is
Short circuit Container case crack
valve can perform its function repeatedly whenever required. accelerated. This leads to loss of capacity and eventually the between
negative strap
cell will fail open. Grid growth due to grid corrosion causes and
positive grid
Fig. 1 Example of valve construction loss in mechanical strength and eventually leads to loss Electrolyte leakage

of contact with the grid. Battery should be replaced before


Valve retainer Rubber one-way valve
these failures. If VRLA batteries are used after the end of Several call´s
short-circuit Ground fault current
Top cover life, the grid growth may cause a crack of container. Capillary
Cover Absorbent mat action can result in a slight film of conductive electrolyte
forming around the crack even though VRLA batteries contain Continuous operation
Thermal runaway
at high voltage
significantly lower volumes of electrolyte and the electrolyte
Expansion of positive grid
is immobilized. This electrolyte film will be in contact with an (In case of continuous operation
Thermal runaway after the life end)
un-insulated metal component and this ground fault current
could result in thermal runaway of a portion of the string or

26 27
8 MODEL NUMBERS OF VRLA BATTERIES MODEL NUMBERS OF VRLA BATTERIES 8

COMPOSITION OF MODEL NUMBERS LC-SERIES COMPOSITION OF MODEL NUMBERS UP-RW SERIES (HIGH POWER BATTERIES FOR UPS)

Figure No. 1 2 3 4 5 6 7 8 9 10 11 12 13 Examples: A, B, C, D Figure No. 1 2 3 4 5 6 7 8 9 10 11 12 No. 7 to 8


Model No. L C - Model No. U P – * W Double-figure fixed codes indicating nominal voltage by
Corresponding model number descriptions are listed below. No. 6 to 7 numerical value.
Please refer to the battery indexes for listings of available
models. Double-figure fixed codes indicating nominal voltage by No. 1 to 3
No. 1 to 3 numerical value. Production division codes of high power batteries for UPS. Examples: 12V = 12, 6V = 06
Product division codes (all of which are assigned by Panasonic).
‘LC’ means Panasonic Valve Regulated Lead-Acid batteries. Examples: 6V = 06, 12V = 12 No. 4 No. 9 to 10
Alphanumeric code indicates properties, shape, etc. of the Indicating wattage at 2V, 10 minute rate discharge.
No. 4 No. 8 to 10 battery.
Fixed single-figure code (alphabetic letter) indicating properties, One to three digit alphanumeric code indicating capacity by No. 11 to 12
shape, etc. of the battery. numbers: decimal point is expressed by R (when some codes R: High power series with standard HB container One-through five-figure (maximum) alphanumeric code for
are not applicable, the proceeding codes are advanced) P: High power and long-life series with flame retardant classifying products by terminal type, package form, destination
container code, etc.
C: Cycle long-life products
Examples: V: High power series with flame retardant container
P: Products combining trickle long-life and
flame retardant battery case Capacity 4Ah 7.2Ah 12Ah 100Ah Examples: J: Japanese label
Q: Trickle super long-life products (20 hour rate)
No. 5 P: English label
R: Small-sized common products (under 17Ah) Model Number 4 7R2 12 100
Indication of wattage. 1: Faston 250
T: Cycle long-life products for energy storage 2: Faston 250 & faston 187
V: Products of ‘R’ types with flame retardant No. 11 to 13 No. 6
battery case (option)
One to three digit alphanumeric code for classifying products Single alphabetic letter for dividing products of the same type Note The last numbers of model number changes depending
X: Trickle long-life products
by terminal type and label design. and the same capacity but having different shapes. (This figure on the country of destination. Please consult Panasonic for
may be omitted when not applicable, then the proceeding more details. Division codes are subject to change.
No. 5 Examples: 1: Faston 250 codes are advanced.)
Single code (alphabetic letter) for dividing products of the same A: Threaded posts
type and the same capacity but having different properties. G: VdS certified product Example: A
(This figure may be omitted when not applicable, then the J: Japanese label
proceeding codes are advanced.) P: English label

Note: Country codes are subject to change.


Model number (example) Model number (example)

LC-R121R3PG LC-P127R2P UP-PW1245P


English label
English label plus VdS product recognition acquired English label The wattage per cell at 10 minutes rate discharge
1.3Ah 7.2Ah 12 V
12V 12V Watt
Trickle and cycle standard type Trickle long-life type, flame retardant For back-up – long-life, flame retardant
VRLA battery VRLA battery VRLA battery – high power type

LC- V1233P LC-X1265PG UP-V W1220J1


Terminal type (faston 250)
English label English label plus VdS product recognition aquired Japanese label
33Ah 65Ah The wattage per cell at 10 minutes rate discharge
12V 12V 12 V
Trickle and cycle standard type, flame retardant Trickle long-life type Watt
VRLA battery VRLA battery For back-up, flame retardant
VRLA battery – high power type

28 29
9 BATTERY LABEL DESIGN BATTERY SELECTION GUIDE 10

INDEX STEPS FOR SELECTING BATTERIES selection of the battery. Any questions at this stage should
ARE DESCRIBED BELOW be asked to battery engineers in depth. Sometimes, new or
1 Brand name improved batteries which are not carried in the brochures
2 Type of battery
Study of required specifications (draft) have become available, and an appropriate battery may be
3 Model number
4 Rated voltage & capacity Study the required specifications (draft) by checking the found among them. Usually, required specifications are
5 Charging recommendation requirements for the battery with the battery selection finalized at this stage.
6 Recycling mark (US)
7 Caution criteria. Technical requirements for selecting the battery are
8 Manufacturer name & country of origin presented below. Request for improving or developing batteries
9 China RoHs markings
10 VdS marking If no battery which will satisfy special requirements can be
11 Recycling mark (JP) Battery selection found by the above-described approach, requests for improving
12 Recycling mark (EU)
First, select several candidate batteries by referring to or developing new batteries should be made to our technical
the technical brochures and data sheets of the batteries department, and these requests should be coordinated as
presently available. Then from the candidates select a battery quickly as possible to allow enough time for studying: the study
which can meet as many of the ideal requirements as takes usually 6 to 12 months or even longer depending on the
possible. In fact, however, battery selection can be seldom request. In this section, guidelines for selecting appropriate
made so smoothly. Practically, possible removal or easing of batteries for specific equipment were mentioned. If further
the requirements should be considered first; then depending information regarding the battery selection is required, please
on the result, a proper battery should be selected from those contact us.
presently available. This way of proceeding enables economic

TECHNICAL REQUIREMENTS FOR BATTERY SELECTION

Electrical requirement Charge condition Temperature and humidity Dimensions, mass , and shape
VIDEO
Voltage range Cycle charge Ambient temperature and humidity Height (mm)______ max.
12
_____V max. _____V min. Trickle/float charge _____°C max._____°C min. Length (mm)______ max.
Charging time _____% max. _____% min. Width (mm)______ max.
Continuous load Charge temperature atmosphere Mass (g)________ av.
___________mA (max.) _____°C max._____°C min. Storage temperature and humidity Terminal shape ___________
___________mA (av.) _____°C max._____°C min.
___________mA (min.) _____% max. _____% min.

Intermittent load/pulse load


Scan QR code to ___________mA (max.) Battery life Others
view 3D animated ___________mA (av.)
video. Cycle life Atmosphere pressure
___________mA (min.)
_________cycles Mechanical condition
Safety
ON/OFF condition
Trickle life _____________________
ON time
_________years
___________
Inter-changeability
OFF time
Storage period Marketability
___________
_____________________ Price

Selection of the battery

30 31
11 BATTERY INDEX BATTERY INDEX 11

BATTERY TYPES AND MODEL NUMBERS TRICKLE DESIGN LIFE 10 – 12 YEARS
PRODUCT CATEGORY RECHARGEABLE 6V • 12V
Trickle design Standard ABS FR ABS = Flame Nominal Rated capacity (Ah) Dimensions (mm) Mass
Application Series Category Model number Page
life (at 20°C) (UL94 HB) Retardant ABS (UL94 V-0) voltage (V) 20 hours rate Length Width Height approx. (kg)
VdS N°
Back up and main power LC-R/RA 6 – 9 years Trickle and cycle standard type LC-P1228P 12 28.0 165.0 125.0 180.0/175.0 86 9.40 -
LC-P/PA/PB 10 – 12 years Trickle long-life type LC-P1238P 12 38.0 197.0 165.0 180.0/175.0 88 12.50 G100002
LC-QA 15 years Trickle super long-life type LC-P1242P 12 42.0 197.0 165.0 180.0/175.0 90 13.50 -
LC-V/VA 6 – 9 years Trickle standard type LC-X1265P*1 12 65.0 350.0 166.0 175.0 92 23.50 G199090
Back up
LC-X/XD/XB 10 – 12 years Trickle long-life type LC-P1275P 12 75.0 350.0 166.0 175.0 94 21.50 -
UP-PW 10 – 12 years High power long-life type LC-XB12100P*1 12 100.0 407.0 173.0 236.0 96 36.50 -
UP-VW/VWA 6 – 9 years High power type LC-P12120P 12 120.0 407.0 173.0 236.0 98 34.50 -
LC-CA/XC - Cycle long-life type LC-P12150BP*2 12 150.0 532.0 183.0 214.0 100 43.00 -
Main power
LC-T - Cycle long-life type for energy storage LC-P12200BP*2 12 200.0 533.0 237.0 216.0 102 57.00 -

LC series standby applications Features


UPS State-of-the-art Absorbed Glass Mat (AGM) technology
LC SERIE S The Panasonic LC series is a comprehensive range of high quality VRLA batteries serving the Energy storage Superior design and low voltage spread gives excellent performance
majority of VRLA battery applications. From batteries with a trickle design life of 6 – 9 years and 10 – 12 years to Communication infrastructure Enhanced lifespan due to low and stable charge current
batteries of 15 years, the series includes solutions for every requirement. Various models are obtainable with flame Wind turbines (pitch system) 100% inspection after final assembly and before shipment
retardant housing and with different terminals. Alarm systems Years of experience in production
Medical equipment S elected batteries with flame retardant battery containers according to UL94 V-0
Emergency lights, etc. Various VdS approved batteries

TRICKLE DESIGN LIFE 6 – 9 YEARS Model number (example)

RECHARGEABLE 6V • 12V LC-R121R3PG L C - X D 12 17A PG


Nominal Rated capacity (Ah) Dimensions (mm) Mass
Model number Page
voltage (V) 20 hours rate Length Width Height approx. (kg) English label plus VdS product recognition acquired Threaded posts, English label, VdS
VdS N°
1.3Ah 17Ah
LC-R061R3P*1 6 1.3 97.0 24.0 55.0 38 0.25 -
12V 12V
LC-R063R4P*1 6 3.4 134.0 34.0 66.0 40 0.60 -
Trickle and cycle standard type Trickle long-life type, advanced design
LC-R064R5P* 1
6 4.5 70.0 48.0 108.0 42 0.70 -
VRLA battery VRLA battery
LC-R067R2P*1 6 7.2 151.0 34.0 100.0 44 1.30 -
LC-R0612P*1 6 12.0 151.0 50.0 100.0 46 1.95 -
LC-R121R3P*1 12 1.3 97.0 47.5 55.0 48 0.55 G196049 LC- V1233P LC-X1265PG
LC-R122R2P*1 12 2.2 177.0 34.0 66.0 50 0.80 G188151
LC-R123R4P*1 12 3.4 134.0 67.0 66.0 52 1.15 G191053 English label English label plus VdS product recognition aquired
LC-R124R5P* 1
12 4.5 70.0 97.0 108.0 54 1.45 - 33Ah 65Ah
LC-R127R2P*1 12 7.2 151.0 64.5 100.0 56 2.50 G193046 12V 12V
LC-RA1212P*1 12 12.0 151.0 98.0 100.0 58 3.85 G100001
Trickle and cycle standard type, flame retardant Trickle long-life type
VRLA battery VRLA battery
LC-RA1215P*1 12 15.0 151.0 98.0 100.0 60 4.15 -
LC-V1233P 12 33.0 195.6 130.0 180.0 62 11.50 -

TRICKLE DESIGN LIFE 10 – 12 YEARS LC - Q A SERIE S The hallmarks of the Panasonic LC-QA battery series are a very long service life of 15 years (at
20°C) and excellent product quality. The latest LC-QA models are the result of a research programme to prolong the
RECHARGEABLE 6V • 12V service life of lead-acid batteries, which Panasonic started back in 1984.
Nominal Rated capacity (Ah) Dimensions (mm) Mass
Model number Page
voltage (V) 20 hours rate Length Width Height approx. (kg)
VdS N°
LC-P067R2P 6 7.2 151.0 34.0 100.0 64 1.20 -
LC-P0612P 6 12.0 151.0 50.0 100.0 66 1.80 - TRICKLE DESIGN LIFE 15 YEARS
LC-P06200TA 6 200.0 407.0 173.0 250.0 68 33.50 -
LC-P122R2P 12 2.2 177.0 34.0 66.0 70 0.80 - RECHARGEABLE 6V • 12V
LC-P123R4P 12 3.4 134.0 67.0 66.0 72 1.15 - Nominal Rated capacity (Ah) Dimensions (mm) Mass
Model number Page
LC-P127R2P 12 7.2 151.0 64.5 100.0 74 2.30 - voltage (V) 20 hours rate Length Width Height approx. (kg)
VdS N°
LC-PA1212P 12 12.0 151.0 98.0 100.0 76 3.65 - LC-QA06210TP 6 210.0 407.0 173.0 250.0 104 36.50 -
LC-PA1216P 12 16.0 151.0 98.0 105.0 78 4.10 - LC-QA1224P 12 24.0 165.0 125.0 175.0 106 9.90 -
LC-XD1217P*1 12 17.0 181.0 76.0 167.0 80 5.90 G104101 LC-QA1242P 12 42.0 197.0 165.0 180.0 108 15.50 -
LC-P1220P 12 20.0 181.0 76.0 167.0 82 5.80 - LC-QA1270P 12 70.0 350.0 166.0 175.0 110 23.50 -
LC-P1224P 12 24.0 165.0 125.0 180.0/175.0 84 8.05 G198049 LC-QA12110TP 12 110.0 407.0 173.0 236.0 112 36.00 -

*1 This battery is also available with a flame retardant battery case resin (UL94 V-0).
32 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0). * 2 This battery is equipped with insert terminals. 33
11 BATTERY INDEX BATTERY INDEX 11

Applications Features Model number (examples) LC CYC LIC SERIE S The Panasonic LC cyclic series is a main power source for electrical devices which require
Mainly telecommunications Innovative Lead-Calcium tin alloy reliable power frequently. Based on our proven technology for stand-by and occasional back-up, this series uses
L C - Q A12 2 4 A P different plate design and other tweaks to achieve long cycle life.
industry minimises harmful corrosion to
Emergency light for trains the positive electrode
M5 threaded posts, English label
UPS systems Reliable seal thanks to a rubber
24Ah
Energy distribution, etc. washer and epoxy resin
12 V
Flame retardant housing
according to UL 94-V0
Trickle super long-life type, flame retardant CYCLE LONG-LIFE AND CYCLE LONG-LIFE FOR ENERGY STORAGE
VRLA battery
RECHARGEABLE 12V
Nominal Rated capacity (Ah) Dimensions (mm) Mass
Model number Page
voltage (V) 20 hours rate Length Width Height approx. (kg)
VdS N°
UP-V W / - P W SERIE S The Panasonic UP-VW / -PW series offers up to 30% higher energy density compared to
LC-CA1212P 12 12.0 151.0 98.0 100.0 128 3.80 -
conventional VRLA batteries with the same dimensions. The series is ideal for UPS systems which require a short
LC-CA1215P 12 15.0 151.0 98.0 100.0 130 4.20 -
discharge time of about 30 minutes or less.
LC-CA1216P 12 16.0 151.0 98.0 105.0 132 4.70 -
LC-XC1222P 12 22.0 181.0 76.0 167.0 134 6.55 -
LC-XC1228P 12 28.0 165.0 125.0 180.0 136 10.50 -
LC-XC1238P 12 38.0 197.0 165.0 180.0 138 15.00 -
TRICKLE DESIGN LIFE 6 – 9 AND 10 – 12 YEARS LC-T1270P*1 12 70.0 350.0 166.0 175.0 140 24.50 -
LC-T12105P*1 12 105.0 407.0 173.0 236.0 142 34.00 -
RECHARGEABLE 6V • 12V
Nominal Rated power (W) Expected trickle Dimensions (mm) Mass
Model number Page LC series cyclic applications Features Model number (examples)
voltage (V) 10 minutes rate design life (at 20°C) Length Width Height approx. (kg)
VdS N° Solar street lighting State-of-the-art Absorbed Glass
UP-VW0645P 6 135.0 6 – 9 years 151.0 34.0 100.0 114 1.30 - Medical equipment Mat (AGM) technology LC- CA1216 P
UP-VW1220P 12 120.0 6 – 9 years 140.0 38.5 100.0 116 1.30 - Lawn mowers Superior design and low voltage
UP-VW1228P 12 200.0 6 – 9 years 151.0 64.5 100.0 118 1.85 - Automated guided vehicles spread gives excellent perfor- English label
UP-VWA1232P 12 192.0 6 – 9 years 151.0 51.0 100.0 120 2.00 - Wheelchairs, etc. mance 16Ah
UP-VW1236P 12 224.0 6 – 9 years 151.0 64.5 100.0 122 2.05 - Enhanced lifespan due to low and 12 V
UP-VW1245P 12 270.0 6 – 9 years 151.0 64.5 100.0 124 2.55 - stable charge current Cycle long-life type
UP-PW1245P 12 270.0 10 – 12 years 151.0 64.5 100.0 126 2.60 - 100% inspection after final VRLA battery
assembly and before shipment
Years of experience in production
Applications Features Model number (example)
S elected batteries with flame
UPS systems 3 0% higher energy density
UP-PW1245P retardant battery containers
Servers, etc. compared to conventional VRLA
according to UL94 V-0
batteries English label
The wattage per cell at 10 minutes rate discharge
Various VdS approved batteries
Superior quality
100% inspection after final 12 V
assembly and before shipment Watt
Years of experience in production For back-up – long-life, flame retardant
Batteries with flame retardant VRLA battery – high power type
battery container according to
UL94 V-0 UP-V W1220J1
Terminal type (faston 250)
Japanese label
The wattage per cell at 10 minutes rate discharge
12 V
Watt
For back-up, flame retardant
VRLA battery – high power type

34 *1 This battery type is designed for energy storage applications. 35


12 STANDARDS STANDARDS 12

PRODUCT CERTIFICATIONS APPLICAPLE STANDARDS IEC 61056-1 Following standards are adopted as harmonized standards.
General purpose Lead-Acid batteries (Valve-Regulated types) -
Alarm security market / VdS approved batteries Following documents are established by consensus and part 1: general requirements, functional characteristics - EN 50272-2 (DIN VDE 0510 part 2)

Nominal Rated
approved by a recognized body, that provides, for common methods of test Safety requirements for secondary batteries and battery in-
Country
Model number voltage capacity and repeated use, rules, guidelines or characteristics for stallations. Safety requirements for batteries and battery
of origin
(V) (Ah) VdS N°
LC-R121R3PG 12 1.3 G196049 China activities or their results, aimed at the achievement of the op- IEC 61056-2 systems-stationary batteries. The ventilation requirements
LC-R122R2PG 12 2.2 G188151 China timum degree of order in a given context. General purpose Lead-Acid batteries (Valve-Regulated types) - for safety rooms are specified herein. Apply the VRLA formula
LC-R123R4PG 12 3.4 G191053 China
part 2: dimensions, terminals and marking together with our batteries.
LC-R127R2PG / LC-V127R2PG 12 7.2 G193046 China
LC-RA1212PG / LC-VA1212PG 12 12.0 G100001 China JIS (Japan Industrial Standard)
LC-XD1217PG/APG 12 17.0 G104101 China
All our VRLA batteries are in compliance with JIS C 8702 IEC 60896-21 GOST R (State Standard of Russia)
LC-P1224PG/APG 12 24.0 G198049 China
LC-P1238PG/APG 12 38.0 G100002 China (almost harmonized with IEC 61056). Stationary Lead-Acid batteries - part 21: Valve-Regulated types - Certifies quality of actually supplied goods and their compli-
LC-X1265PG / LC-P1265PG 12 65.0 G199090 China methods of test ance with contractual terms. A quality certificate contains
Note: Standards should be based on the consolidated a profile of goods or confirms their compliance with certain
UL approved batteries results of science, technology and experience, and aimed at This part of IEC 60896 applies to all stationary Lead-Acid cell standards or specifications of a delivery order. A certificate
All our VRLA batteries are in compliance with UL 1989 (standby the promotion of optimum community benefits. and monobloc batteries of the Valve-Regulated type for float of compliance is intended for certification of goods produced
batteries) – file number MH 13723. UL 1989 requires that the IEC standards cover a vast range of technologies from power charge applications, (i.e. permanently connected to a load and by Russian companies or shipped to Russia by an importer-
battery is free from the hazard of bursting, that is, when the generation, transmission and distribution to home appliances to a d.c. power supply), in a static location, (i.e. not generally company.
battery is overcharged the vent valve opens to release internal and office equipment, semiconductors, fibre optics, batteries, intended to be moved from place to place) and incorporated
pressure. solar energy, nanotechnology and marine energy as well as into stationary equipment or installed in battery rooms for UN2800 Transport regulations
many others. use in telecom uninterruptible power supply (UPS), utility All Panasonic VRLA batteries listed in this handbook comply
FACTORY CERTIFICATIONS IEC standards are also being adopted as harmonized stand­ switching, emergency power, or similar applications. with ADR/IMDG SP 238 (road/sea) and IATA SP A67 and PI 806
ards by other certifying bodies such as BSI (Great Britain), (air). These batteries have to be handled as non-dangerous
ISO 9001 / ISO 14001 CSA (Canada), UL & ANSI/INCITS (USA), SABS (South Africa), IEC 60896-22 goods (non-spillable).
Quality management system (ISO 9001) defines what the SAI (Australia), SPC/GB (China), DIN (Germany) and JIS (Japan). Stationary Lead-Acid batteries - part 22: Valve-Regulated-
organization does to ensure that its products or services sat- IEC standards harmonized by other certifying bodies generally types - requirements
isfy the customer’s quality requirements and comply with any have some noted differences from the original IEC standard.
regulations applicable to those products or services. ISO 14001 Same as above, but defining the requirements.
is primarily concerned with ‘environmental ma­­n­agement’. In IEC 61056
plain language, this means what the organization does to Specifies the general requirements, functional characteristics
minimize harmful effects on the environment caused by its and methods of test for all general purpose lead acid cells
activities. and batteries of the valve regulated type for either cyclic or
float charge application; in portable equipment, for instance,
OHSAS 18001 incorporated in tools, toys, or in static emergency, or uninter-
OHSAS 18001 is an Occupation Health and Safety Ass­ess­ ruptible power supply and general power supplies.
ment Series for health and safety management systems. It is The cells of this kind of Lead-Acid battery may either have flat-
intended to help organizations to control occupational health plate electrodes in prismatic containers or have spirally wound
and safety risks. It was developed in response to widespread pairs of electrodes in cylindrical containers. The sulfuric acid
demand for a recognized standard against which to be certi- in these cells is immobilized between the electrodes either
fied and assessed. by absorption in a microporous structure or in a gelled form.

36 37
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R061R3P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R061R3P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.065A - 0.26A - 0.65A - 1.30A - 2.60A -
DIMENSIONS (MM) 4.75 Control voltage: 7.25V - 7.45V Discharge current
Cycle use 0.26A 0.65A 1.30A 2.60A 3.90A
Initial current: 0.52A or smaller
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

6.35

3.2
Terminal type CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
97±1 (187)

(4.75)
(92.9) 24±1 120 120
(4.2) 120 120
120
120
120 120
120
120
100
100 100
100

(%)
(%) (%)
100

ratio
100 100
100

ratioratio
(%)
100
80 100
80

(%)
80 80

(%)
(%) (%)
5°C
5°C

ratio
retention
50±1

ratio
retention
80
80
80 80
80
80 (41°F)

Capacity
60 60 (41°F)

Capacity
60 60

(%)
5°C
5°C

(%)
5°C

retention
retention
Discharge
Discharge Discharge
Discharge Discharge
Discharge

retention
(41°F)
(41°F)

Capacity
Capacity
60
60 60
60 40°C
40°C 30°C
30°C 25°C (41°F)
25°C

Capacity
60
40
40 depth
depth100%
100% depth
depth 50%
50% depth
depth30%
30% 60
40
40
Discharge
Discharge Discharge
Discharge Discharge
Discharge

Capacity
(104°F) (86°F) (77°F)

Capacity
Discharge Discharge Discharge (104°F)
40°C (86°F)
30°C (77°F)
25°C
40
40 depth 100% depth 50% depth 30% 40
40 40°C
40°C 30°C
30°C 25°C
25°C
40
20 depth 100%
depth 100% depth
depth
Ambient 50%
50%
temperature depth 30%
depth 30% 40
20
(96.5) (23.5) 20 Ambient temperature 20

Capacity
(104°F) (86°F)

Capacity
(104°F) (86°F) (77°F)
(77°F)

(0.3)

Capacity
(104°F) (86°F) (77°F)
25°C
25°C(77°F)
(77°F)
20
20
20 Ambient
Ambient
Ambient temperature
temperature
temperature 20
20
20
00 00
Contents indicated (including the recycle marking, etc.) 25°C(77°F)
25°C
25°C (77°F)
(77°F)
0 400 800 1,200 00 22 44 66 88 10 10 12 12 14
14 16
16 18
18 20
20
are subject to change without notice. Battery case resin: standard (UL94 HB) 000 0 400 800 1,200 000
Number
Number ofofcycles
cycles(times)
(times) Storage
Storageperiod
period(mth.)
(mth.)
000 400
400
400 800
800
800 1,200
1,200
1,200 000 222 444 6 8
66 88 10 10
10 12 12
12 14 14 16
14 16 18
16 18 20
18 20
20
Numberofof
Number ofcycles
cycles(times)
(times) Storageperiod
Storage
Storage period(mth.)
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Number cycles (times)
Name LC-R061R3P*1 30 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
Nominal voltage 6V 20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
40°C 160
160 8.00
8.00 120
120
Nominal capacity (20 hour rate) 1.3Ah Battery
Batteryvoltage
voltage
10 160
140
160
140
160 8.00
7.00
8.00
7.00
8.00 120
120 0.05CA
Length 97mm Batteryvoltage
Battery voltage 120
100 0.05CA
Battery voltage 100 0.10CA
0.10CA
Dimensions Width 24mm 0.8
0.8 140
140
120
120
140 7.00
7.00
6.00
6.00
7.00 0.05CA
0.05CA

(%)
(%) (%)
5 Charge
Chargequantity
quantity(to
(todischarge
dischargequantity)
quantity) 100 0.05CA

(V)
100

(CA)

(V) (V)
(h)

0.25CA

(CA)(CA)
100
80
80 0.10CA
0.25CA
0.10CA
0.10CA
Height 55mm 25°C 0.8
0.8 100
120
120
100 5.00
6.00
6.00
5.00 0.50CA
0.50CA

(%)
ŚŚDischarge

(%) (%)
0.8 120 6.00

quantity

voltage
Discharge

quantity

voltage
(%)
3 Charge
Charge quantity(to
quantity (todischarge
dischargequantity)
quantity)
0.6

(%)

(V)
0.6

(CA)
Charge—quantity
100% (to discharge
100%(0.05CA*20H) quantity) 0.25CA
0.25CA

(V)
——

current
(CA)
(0.05CA*20H) 0.25CA

current
Approx. mass 0.25kg — 80
Duration of discharge

100 5.00 80

Capacity
100
80 5.00
4.00 80 0.50CA

Capacity
80 4.00 60 0.50CA

(%)
100 Discharge 5.00 1.00CA

quantity
50% (0.05CA*10H)
Discharge 60 0.50CA

voltage
quantity
—Ś 1.00CA

voltage
Ś — 50% (0.05CA*10H)

(%)

Ś—Discharge

quantity

voltage
Terminal Faston 187 0.6
0.6
0.6 100%(0.05CA*20H)
—100% (0.05CA*20H)

current
— 2.00CA

current
ś— —
Charge
— 100%
Charge (0.05CA*20H) 2.00CA

current
ś

Capacity
0.4 80 — 4.00

Capacity
0.4 60
80
60 3.00
4.00
3.00

Battery
60
60 1.00CA

Capacity
Battery
80 ——— 50%(0.05CA*10H)
50%
—Charge (0.05CA*10H) 4.00 60 1.00CA
3.00CA

Charge
ȼ— Charge voltage:
voltage:7.35V
7.35V(2.45V/cell) 1.00CA
3.00CA

Charge
20 hour rate 1.3Ah — 50% (0.05CA*10H) (2.45V/cell) 40
60 ȼ 40

Charge
0°C

Charge
ś ś Charge
Charge 2.00CA
2.00CA
2.00CA
0.4
0.4 60
40
60 śCharge
Chargecurrent:
current:0.40CA
0.40CA 3.00
2.00
3.00

Battery
40 2.00

Battery
10 hour rate 1.2Ah 0.4 60 3.00

Battery
3.00CA

Charge
3.00CA

Charge
Capacity ȼ Charge
Charge voltage:
voltage: 7.35V
7.35V (2.45V/cell)
(2.45V/cell) 40
0.2 40 3.00CA

Charge
ȼŜTemperature: 25°C (77°F)
0.2 Charge voltage: 7.35V (2.45V/cell)

Charge
Ŝ Temperature: 25°C (77°F) 40

Charge
ȼ
20

Charge
(25°C) 30 20
40
40 Chargecurrent:
Charge current:0.40CA
0.40CA 1.00
2.00
2.00 20
3 hour rate 1.1Ah 20
40 Charge current: 0.40CA 1.00
2.00
0.2
0.2
0.2 Ŝ Ŝ Temperature:
ŜTemperature:
Charge
Chargecurrent
Temperature: 25°C(77°F)
25°C
current
25°C (77°F)
(77°F)
1 hour rate 0.9Ah 00 20
20
20
20
00
20
20 1.00
0.00
1.00
0.00
1.00 00
-15°C 00 22 44 Chargecurrent
Charge current
66 current
Charge 88 10
10 12
12
Fully charged battery
10 000 000 0.00
0.00 00-15
0-15 00 15
15 30
30 45
45
(min.)

Impedance 50mΩ Charge 0.00


(25°C) Chargetime
time(h)
(h) Battery
Batterytemperature
temperature(°C)
(°C)
000 222 444 666 888 10
10
10 12
12
12 -15
-15 000 15
15 3030 45
45
-15 15 30 45
40°C 102% 5 Chargetime
Charge
Charge time(h)
time (h)
(h) Battery
Battery temperature
temperature (°C)
(°C)
Battery temperature (°C)
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
10.00
10.00
CHARACTERISTICS
After 3 month 91% 1 10.00
10.00
10.00
Self-discharge 0.01 0.03 0.1 0.3 1 3 10
After 6 month 82%
(25°C)
Discharge current (A) 7.50
7.50
After 12 month 64%

(V)
(V) (V)
7.50
7.50
7.50

voltage
voltage
(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
voltage (V)
5.00
5.00

voltage
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 0.325A
0.325A 0.065A
0.065A

Terminal
Terminal
1.30A
1.30A
4.80V 39.1 30.8 20.1 15.4 12.9 9.61 6.78 5.42 3.73 2.89 2.15 1.65 1.36 1.10 0.726 0.393 5.00
5.00
5.00 3.90A
3.90A 0.065A
0.065A
0.325A
0.325A
0.325A 0.065A

Terminal
Terminal
1.30A
1.30A
Terminal
4.95V 36.2 28.9 19.7 15.3 12.7 9.51 6.74 5.37 3.66 2.86 2.14 1.64 1.35 1.09 0.723 0.392 3.90A
3.90A 1.30A
2.50 3.90A
2.50
5.10V 33.4 27.1 19.2 15.0 12.5 9.40 6.68 5.32 3.58 2.79 2.12 1.63 1.34 1.08 0.715 0.391
2.50
2.50
2.50
5.25V 29.7 24.3 17.8 13.9 11.8 9.19 6.57 5.21 3.51 2.69 2.08 1.62 1.33 1.07 0.712 0.390
5.40V 25.1 21.4 15.9 13.0 11.5 8.87 6.47 5.10 3.41 2.57 2.04 1.60 1.30 1.05 0.704 0.388
0.00
0.00
00 11 22 33 55 77 10 10 20
20 40
40 60
60 22 44 66 88 1010 20
20 40
40
0.00
0.00
0.00 (min.)
(min.) (h)
(h)
AMPERE TABLE (25°C) (Ampere/battery) 000 111 222 333 555 777 10 10 20
20 40
40 6060 222 444 666 888 10
10 20
20 40
40
10 20 40 60 10 20 40
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.)
(min.)
(min.) Duration
Durationofofdischarge
discharge (h)
(h)
(h)
4.80V 7.02 5.53 3.59 2.67 2.22 1.64 1.16 0.921 0.634 0.484 0.363 0.276 0.228 0.185 0.122 0.066 Durationof
Duration ofdischarge
discharge
Duration of discharge
4.95V 6.52 5.18 3.52 2.65 2.18 1.63 1.15 0.912 0.621 0.480 0.361 0.274 0.226 0.184 0.121 0.065
5.10V 6.01 4.86 3.43 2.60 2.15 1.61 1.14 0.903 0.609 0.468 0.358 0.273 0.224 0.183 0.120 0.065
5.25V 5.34 4.35 3.18 2.42 2.04 1.57 1.12 0.885 0.596 0.451 0.352 0.272 0.222 0.182 0.119 0.065
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
5.40V 4.51 3.85 2.83 2.26 1.99 1.52 1.10 0.867 0.578 0.433 0.343 0.271 0.217 0.181 0.117 0.063 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

38 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V061R3P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V061R3P. 39
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R063R4P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R063R4P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type
0.17A - 0.68A - 1.7A - 3.4A - 6.8A -
DIMENSIONS (MM) 4.75 Control voltage: 7.25V - 7.45V Discharge current
Cycle use 0.68A 1.7A 3.4A 6.8A 10.2A
Initial current: 1.36A or smaller
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

6.35

3.2
(187) CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
+1.5
34±1 134 -0.5
120
120 120
120
(10.1) (129.8)
120
120 120
120
100
100 100
100

(%)
(%)(%)
(6)
100
100 100
100

ratio
(%)
ratio
80
80 80
80

(%)(%)

ratio
(%)

ratio
80 80 5°C
5°C

retention
80 80

retention
60±1

Capacity
(%)
60 60

Capacity
60 60 (41°F)
5°C
(41°F)
5°C

retention
retention
Discharge Discharge Discharge

Capacity
60 Discharge Discharge Discharge 60 (41°F)

Capacity
60 60 (41°F)
40
40 depth
depth100%
100%
Discharge depth
depth 50%
50%
Discharge depth
depth 30%
Discharge 40
40 40°C
40°C 30°C
30°C 25°C
25°C
Discharge Discharge Discharge

Capacity
40 depth 40 (104°F)
(104°F)
40°C (86°F)
(86°F)
30°C (77°F)
(77°F)
25°C
(33.5) (133) 40 depth 100%
100% depth
depth 50%
50% depth
depth 30%
30% 40 40°C 30°C 25°C

Capacity
20
20 Ambient
Ambient temperature
temperature 20
20

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)

(0.3)
20
20 25°C
25°C(77°F)
Ambient(77°F)
Ambient temperature
temperature 20
20
00 25°C 00
Contents indicated (including the recycle marking, etc.) 25°C (77°F)
(77°F)
00 00 400
400 800
800 1,200 00 00 22 44 66 88 10 10 12 12 14 14 16
16 18
18 20
20
are subject to change without notice. Battery case resin: standard (UL94 HB)
Storage
88 period
Storage period(mth.)
00 Number
Number
400 of
400 ofcycles
cycles (times)
(times)
800
800 1,200
1,200 00 22 44 66 10 (mth.)
10 12
12 1414 1616 18
18 20
20
Number
Number ofof cycles
cycles (times)
(times) Storage
Storage period
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-R063R4P*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 6V CHARGE CHARACTERISTICS
160 FOR CYCLE USE 8.00 AND BY DISCHARGE CURRENT
20 160 Batteryvoltage
Battery voltage 120
120
Nominal capacity (20 hour rate) 3.4Ah
40°C 160
160
140 8.00
8.00 120
140 Battery
Battery voltage
voltage 7.00 120 0.05CA
0.05CA
Length 134mm 10 100
100 0.10CA
0.8 140
140 7.00
7.00 0.10CA
0.8 120
120 6.00
6.00 0.05CA
0.05CA

(%)
Dimensions Width 34mm Chargequantity
quantity(to
(todischarge
discharge quantity)
quantity)

(%)(%)
Charge 100

(CA)
100 0.10CA

(CA)
0.25CA

(V)
5 0.10CA
0.25CA

(V) (V)
0.8 80
(h)

Height 66mm 0.8 120


100
120
100 6.00
5.00
6.00
5.00 80 0.50CA

quantity

(%)
Charge quantity (to
(to discharge
Discharge discharge quantity) 0.50CA

(%)
quantity

(%) (%)
Ś Discharge

(CA)
Charge quantity quantity)

voltage
Ś
0.6 0.25CA

(CA)

voltage
0.6 0.25CA

(V)
current
3 25°C 100%(0.05CA*20H)
— 100% (0.05CA*20H) 80

current
——
Approx. mass 0.60kg 100
100
80 — 5.00
5.00
4.00 80 0.50CA

Capacity
quantity
Discharge 1.00CA
0.50CA
Duration of discharge

80 4.00

Capacity
Ś 60 1.00CA

quantity

(%)
— 50% (0.05CA*10H)
Discharge

voltage
0.6 Ś—
—— 50% (0.05CA*10H) 60

voltage
0.6

current

— 100%
100% (0.05CA*20H) 2.00CA

current
Terminal Faston 187 — Charge
— (0.05CA*20H) 2.00CA
80 4.00

Capacity
ś 1.00CA
0.4 60
80 ś Charge 3.00
4.00 60

Capacity
0.4 60 —
— 50%
50% (0.05CA*10H) 3.00 60 1.00CA
3.00CA

Battery
— Charge (0.05CA*10H)

Charge
— voltage:7.35V
7.35V (2.45V/cell)
(2.45V/cell) 3.00CA

Battery
Charge
ȼ Charge voltage: 40 2.00CA

Charge
20 hour rate 3.4Ah ȼ Charge 40 2.00CA

Charge
ś
60 0.4
0.4 60
40
60
ś Charge
Chargecurrent:
Charge current:0.40CA
0.40CA 3.00
2.00
3.00 3.00CA

Battery
Charge
40 Charge voltage: 7.35V (2.45V/cell) 2.00 3.00CA

Battery
Charge
ȼ 40
0.2 Ŝ Charge voltage:25°C
7.35V (2.45V/cell)

Charge
Capacity 10 hour rate 3.1Ah 0°C 0.2 ȼ Temperature: (77°F) 40

Charge
Ŝ Temperature:
Charge 25°C (77°F) 20
40
20
40 Charge current:
current: 0.40CA
0.40CA 2.00
1.00
2.00 20
(25°C) 3 hour rate 2.8Ah 30 0.2 20 Temperature: 25°C (77°F) 1.00
0.2 Ŝ
Ŝ Temperature: 25°C (77°F)
Chargecurrent
Charge current 20
1 hour rate 2.3Ah 00 20
2000 1.00
0.00
1.00 20
00
Charge current
0.00
Charge current
Fully charged battery 00 00 00 22 44 66 88 10
10 12
12 0.00
0.00 00-15
-15 00 15
15 30
30 45
45
Impedance 30mΩ
(min.)

10 -15°C Charge time (h)


(25°C) 00 22 4
Charge
4 6 8
6time (h)
8 10
10 12
12 -15
-15 00 Battery
Batterytemperature
15
temperature
15
(°C)
30
(°C)
30 45
45
40°C 102% Charge
Charge time
time (h)
(h) Battery
Battery temperature
temperature (°C)
(°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
10.00 CHARACTERISTICS
10.00
After 3 month 91% 1 10.00
10.00
Self-discharge 0.1 0.3 1 3 10 30 100
After 6 month 82%
(25°C) Discharge current (A) 7.50
After 12 month 64% 7.50

(V)
(V) (V)
7.50

voltage
7.50

voltage
(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
voltage
5.00 0.850A 0.170A
5.00

Terminal
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 0.850A 0.170A
3.40A

Terminal
5.00 10.2A 3.40A
4.80V 102 80.6 52.6 40.2 33.7 25.1 17.7 14.2 9.76 7.55 5.62 4.32 3.56 2.86 1.90 1.03 5.00 10.2A 0.850A
0.850A 0.170A
0.170A

Terminal
Terminal
10.2A 3.40A
3.40A
4.95V 94.8 75.6 51.6 39.9 33.1 24.9 17.6 14.1 9.56 7.49 5.59 4.29 3.54 2.85 1.89 1.03 2.50 10.2A
2.50
5.10V 87.4 70.8 50.2 39.1 32.6 24.6 17.5 13.9 9.37 7.30 5.54 4.26 3.51 2.83 1.87 1.02
2.50
2.50
5.25V 77.7 63.4 46.5 36.4 30.9 24.0 17.2 13.6 9.17 7.04 5.45 4.23 3.48 2.80 1.86 1.02
5.40V 65.6 56.1 41.5 33.9 30.1 23.2 16.9 13.4 8.92 6.71 5.34 4.18 3.39 2.75 1.84 1.01 0.00
0.00 0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.00 0 1 2 3 5 7
(min.) 10 20 40 60 2 4 6 8 10
(h) 20 40
0.00
AMPERE TABLE (25°C) (Ampere/battery) 00 11 22 33 55 (min.)
77 10
10 20
20 40
40 60
60 22 44 66 8(h)
8 1010 20
20 40
40
(min.)
(min.) Duration of discharge (h)
(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h Duration of discharge
4.80V 18.4 14.4 9.40 6.99 5.81 4.30 3.02 2.41 1.66 1.26 0.949 0.722 0.595 0.484 0.318 0.171 Duration
Duration of
of discharge
discharge
4.95V 17.0 13.6 9.21 6.94 5.71 4.25 3.00 2.39 1.62 1.24 0.945 0.718 0.590 0.482 0.316 0.171
5.10V 15.7 12.7 8.97 6.80 5.62 4.20 2.97 2.36 1.59 1.22 0.935 0.713 0.586 0.478 0.313 0.170
5.25V 14.0 11.4 8.31 6.33 5.34 4.11 2.93 2.31 1.56 1.18 0.921 0.710 0.581 0.475 0.312 0.170
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
5.40V 11.8 10.1 7.41 5.90 5.19 3.97 2.88 2.27 1.51 1.13 0.897 0.708 0.567 0.472 0.307 0.165 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

40 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V063R4P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V063R4P. 41
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R064R5P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R064R5P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.225A - 0.900A - 2.25A - 4.50A - 9.00A -
DIMENSIONS (MM) Terminal type Control voltage: 7.25V - 7.45V Discharge current
Cycle use 0.900A 2.25A 4.50A 9.00A 13.5A
4.75 Initial current: 1.80A or smaller
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

6.35

3.2
CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
70±1 48±1

(6)
(7) (7) (187)
120
120 120
120
120
120 120
120
120
100
100 100
100

(%)
(%) (%)
(1.5)
100 100

ratio
100 100
100

ratioratio
(%)
(%)
80
80 80
80

101.7±1.5

(%)
(%) (%)
5°C

ratio
ratio
5°C

retention
80 80

retention
80 80
80

Capacity
60 60

Capacity
60 60 (41°F)
(41°F)

(%)
70±1 5°C
5°C5°C

retention
retention
retention
Discharge
Discharge Discharge
Discharge Discharge
Discharge

Capacity
60 60 (41°F)

Capacity
60 60
60 40°C 30°C 25°C (41°F)
(41°F)
40
40 depth
depth100%
100% depth
depth50%
50% depth
depth30%
30% 40
40 40°C 30°C 25°C
Discharge
Discharge
Discharge Discharge
Discharge
Discharge Discharge
Discharge
Discharge

(0.3)

Capacity
Capacity
(104°F)
(104°F)
40°C (86°F)
(86°F)
30°C (77°F)
(77°F)
25°C
40
40 depth
depth100%
depth 100%
100% depth
depth50%
depth 50% depth
depth30%
30% 40
40
40 40°C
40°C 30°C
30°C 25°C
25°C
Ambient
Ambienttemperature 20

Capacity
20
20 temperature 20

Capacity
Capacity
(104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
(77°F)
25°C
25°C(77°F)
(77°F)
Ambient
(69.2) (47.4) 20
20 Ambienttemperature
Ambient temperature
temperature 20
20
20
00 25°C 00
Contents indicated (including the recycle marking, etc.) 25°C(77°F)
25°C (77°F)
(77°F)
00 00 400
400 800
800 1,200
1,200 000 00 22 44 66 88 10 10 12 12 1414 16 16 18 18 20 20
are subject to change without notice. Battery case resin: standard (UL94 HB)
00 Number
Number
400
400 of cycles (times)
400 of cycles (times)
800
800 1,200
1,200
1,200 000 222 444 Storage
66 888period
6Storage period
10
10 (mth.)
10 12(mth.)
12 14
12 1414 1616
16 1818
18 2020
20
Number
Numberof
Number ofcycles
of cycles(times)
cycles (times) Storage
Storage
Storageperiod
period
period(mth.)
(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-R064R5P*1 30 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
Nominal voltage 6V 20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
160
160 Battery
8.00
8.00 120
120
Nominal capacity (20 hour rate) 4.5Ah Batteryvoltage
voltage
40°C
160
160
160
140
140 8.00
8.00
7.00
7.00 120
120
Length 70mm 10 Battery
Battery voltage
Batteryvoltage
voltage 120 0.05CA
0.05CA
100
100 0.10CA
0.10CA
0.8 140
140
140
120
120 7.00
7.00
6.00
6.00 0.05CA
Dimensions Width 48mm 0.8 0.05CA
0.05CA

(%)
Charge
Chargequantity
quantity(to
(todischarge
dischargequantity) 100

(%)(%)
quantity) 100
100 0.10CA

(CA)
5 0.10CA

(CA)(CA)
0.25CA

(V)
0.10CA
0.25CA

(V) (V)
(h)

Height 108mm 0.8


0.8
0.8 120
120
100
120
100 6.00
5.00
6.00
5.00 8080 0.50CA
Charge quantity (to discharge 0.50CA

(%) (%)
(%)
Charge quantity (to
(todischarge
dischargequantity)

quantity

(%)
ŚŚDischarge

(%)
quantity
25°C Charge Discharge
quantity quantity)

voltage
(CA)
0.25CA

voltage
0.6 0.25CA

(V)
(CA)
3 0.6 0.25CA

(V)
—— 80
80

current
—100%
100%(0.05CA*20H)

current
Approx. mass 0.70kg 100
100
100
— (0.05CA*20H) 5.00
5.00 80 0.50CA
0.50CA
Duration of discharge

80 4.00

Capacity
quantity
0.50CA

(%)
80 Discharge 4.00

Capacity
quantity
Ś Discharge

(%)
Ś 60

voltage
quantity
— Discharge 60 1.00CA

voltage
0.6
0.6
Ś—
—— 50%
50%(0.05CA*10H)
(0.05CA*10H) 1.00CA

voltage
0.6 —

current
— 100% (0.05CA*20H)

current
Terminal —— 100%
100%(0.05CA*20H)
Faston 187 ś—

current
80 — (0.05CA*20H) 4.00 2.00CA
2.00CA

Capacity
80 Charge

Capacity
0.4 80 ś Charge 4.00 60

Capacity
0.4 6060 —
——
— 50%
— 50% (0.05CA*10H)
50%(0.05CA*10H)
(0.05CA*10H) 3.00
3.00 60
60 1.00CA
1.00CA
1.00CA

Battery

Battery
3.00CA

Charge
3.00CA

Charge
20 hour rate 4.5Ah ȼȼ Charge
Charge voltage:
voltage:7.35V
7.35V(2.45V/cell)
(2.45V/cell) 40 2.00CA
40 2.00CA

Charge
ś Charge
ś Charge

Charge
60 0.4
0.4 60
60
ś Charge 3.00 2.00CA
0.4 60 ȼCharge
Chargecurrent:
current:0.40CA 3.00

Battery
4040 0.40CA 2.00
2.00 3.00CA

Charge

Battery
3.00CA

Charge
0°C Charge voltage: 7.35V (2.45V/cell)

Battery
Charge voltage: 7.35V (2.45V/cell) 40 3.00CA

Charge
10 hour rate 4.1Ah ȼ 40

Charge
Capacity ȼ Charge voltage: 7.35V (2.45V/cell) 40

Charge
0.2
0.2

Charge
ŜŜTemperature:
Temperature: 25°C
25°C(77°F)
(77°F)
40 Charge
Charge current: 0.40CA 2.00 20
(25°C) 40
2040
20 Chargecurrent:
current:0.40CA
0.40CA 2.00
1.00
2.00
1.00 20
3 hour rate 3.6Ah 30 0.2
0.2 Ŝ Temperature: 25°C (77°F)
(77°F)
Ŝ Temperature:
0.2 Ŝ Temperature:
Charge
Chargecurrent
25°C
25°C
current (77°F) 20
20
1 hour rate 3.1Ah 00 20
20
20 1.00
1.00
1.00 20
00 0.00
0.00 00
Charge current
Charge current
Fully charged battery 000 000 00 22 44 Charge
66 current
88 10
10 12 0.00
12 0.00 00-15 00 15 30 45
Impedance 20mΩ -15°C 0.00 0 -15 15 30 45
(min.)

(25°C) 10
000 222 Charge
4
Charge
44 6time
66time(h)
888
(h) 10
10
10 12
12
12 -15
-15
-15
00 Battery
0 Batterytemperature
15 30
temperature
15
15
(°C)
30
30(°C) 4545
45
Charge time
Charge time (h) Battery temperature (°C)
40°C 102% Charge time(h)(h) Battery
Batterytemperature
temperature(°C)
(°C)
5
Temperature dependency 25°C 100%
of capacity (20 hour rate) 3
0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
10.00
10.00
After 3 month 91% 1 10.00
Self-discharge
10.00
10.00
After 6 month 82% 0.1 0.3 1 3 10 30 100
(25°C) Discharge current (A)
After 12 month 64% 7.50
7.50

(V)
(V)(V)
7.50
7.50
7.50

voltage
voltage
(V)
(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
voltage
voltage
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 5.00
5.00 1.125A 0.225A
0.225A
1.125A

Terminal
Terminal
5.00 4.50A
4.50A 1.125A 0.225A
4.80V 135 107 69.7 53.2 44.6 33.3 23.5 18.8 12.9 9.99 7.44 5.71 4.72 3.79 2.51 1.36 5.00
5.00 13.5A
13.5A 0.225A

Terminal
4.50A 1.125A
1.125A 0.225A

Terminal
Terminal
4.95V 125 100 68.3 52.8 43.9 32.9 23.3 18.6 12.7 9.92 7.40 5.68 4.68 3.78 2.50 1.36 13.5A 4.50A
4.50A
13.5A
13.5A
5.10V 116 93.7 66.5 51.8 43.1 32.5 23.1 18.4 12.4 9.66 7.33 5.64 4.64 3.75 2.48 1.35 2.50
2.50
2.50
5.25V 103 84.0 61.6 48.2 41.0 31.8 22.7 18.0 12.1 9.32 7.21 5.60 4.60 3.70 2.46 1.35 2.50
2.50
5.40V 86.9 74.2 55.0 44.9 39.9 30.7 22.4 17.7 11.8 8.88 7.07 5.53 4.49 3.64 2.44 1.34
0.00
0.00
0.00 00 11 22 44 66 88 10 10 20
20 40
40 60
60 22 44 66 88 10 10 20
20 4040
(Ampere/battery) 0.00
0.00 0 1 2 4 6 (min.)
8 10 20 40 60 2 4 6 8 (h)10 20 40
AMPERE TABLE (25°C) 00 11 22 44 66 (min.)
88 10 20 40 60 22 44 66 (h)
88 10 20 40
(min.) 10 20 40 60 (h) 10 20 40
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.)
(min.) (h)
(h)
Duration
Durationofofdischarge
discharge
4.80V 24.3 19.1 12.4 9.25 7.69 5.69 4.00 3.19 2.19 1.69 1.25 0.956 0.788 0.633 0.419 0.227 Duration of discharge
Duration
Durationof
ofdischarge
discharge
4.95V 22.6 17.9 12.2 9.19 7.56 5.63 3.98 3.16 2.14 1.68 1.24 0.950 0.781 0.630 0.417 0.226
5.10V 20.8 16.8 11.9 9.00 7.44 5.56 3.94 3.13 2.10 1.63 1.23 0.944 0.775 0.625 0.413 0.226
5.25V 18.5 15.1 11.0 8.38 7.06 5.44 3.88 3.06 2.06 1.58 1.21 0.938 0.769 0.618 0.411 0.225
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
5.40V 15.6 13.3 9.81 7.81 6.88 5.25 3.81 3.00 2.00 1.50 1.19 0.925 0.750 0.608 0.406 0.224 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

42 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V064R5P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V064R5P. 43
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R067R2P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R067R2P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type
0.360A - 1.44A - 3.60A - 7.20A - 14.4A -
DIMENSIONS (MM) Control voltage: 7.25V - 7.45V Discharge current
4.75 6.35 Cycle use 1.44A 3.60A 7.20A 14.4A 21.6A
Initial current: 2.88A or smaller
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

6.35

4.5
3.2
(187)
(250) CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
+1.5 +1.5
151 -0.5 34 -0.5 120
120 120
120
130.3 9 120 120
120 120

6
100
100 100
100

(%) (%)
(%) (%)
120 120

ratio
ratio ratio
100
100
8080 100
100
8080
100 100

(%) (%)
(%) (%)

(%)
5°C
5°C

ratio
retention
retention
+1.5
94 -0.5
8080 8080

Capacity
Capacity
6060

ratio
6060 (41°F)
(41°F)
80 80 5°C5°C

retention
(%)

retention
Discharge
Discharge Discharge
Discharge Discharge
Discharge 5°C

Capacity
60 60

Capacity
60

retention
4040 depth
depth100%
100% depth depth50%50% depth
depth30%
30% 60
4040 40°C
40°C 30°C
30°C 25°C (41°F)
25°C (41°F)

Capacity
60 60 (41°F)

Capacity
Capacity
Discharge
Discharge Discharge
Discharge Discharge
Discharge (104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)

0.3
4040 Discharge
depth 100% Discharge
depth 50% Discharge
depth 30% 4040 40°C
40°C 30°C
30°C 25°C
25°C
2020 depth 100%
Ambient
Ambientdepth 50%
temperature
temperature depth 30% 2020

Capacity
40 40 40°C 30°C 25°C

Capacity
depth 100% depth 50% depth 30% (104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)

Capacity
150.2 33.2 25°C
25°C(77°F)
(77°F) (104°F) (86°F) (77°F)
20020 Ambient
Ambient temperature
temperature 2020
200 Ambient temperature 200 0
Contents indicated (including the recycle marking, etc.) 25°C
25°C(77°F)
(77°F)
00 400
400
25°C (77°F) 800
800 1,200
1,200 00 22 446 6 8 8 1010 1212 1414 1616 1818 2020
are subject to change without notice. Battery case resin: standard (UL94 HB) 00 00
0 Number
Numberofofcycles
cycles(times)
(times) 0 Storage
Storageperiod
period(mth.)
(mth.)
00 400
400 800
800 1,200
1,200 0 0 2 2 4 4 6 6 8 8 1010 1212 1414 1616 1818 2020
0 400 800 1,200 0 2 4 6 8 10 12 14 16 18 20
Number
Number ofofcycles (times)
cycles (times) Storage period (mth.)
Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Number of cycles (times) Storage period (mth.)
Name LC-R067R2P*1 30 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
Nominal voltage 6V 20 CHARGE CHARACTERISTICS
160
160 FOR CYCLE USE 8.00
8.00 AND BY DISCHARGE CURRENT
Battery
Batteryvoltage
voltage 120
120
Nominal capacity (20 hour rate) 7.2Ah 40°C 140
140
160
160 7.00
7.00
8.00
8.00 120 0.05CA
0.05CA
Length 151mm 10 160 Battery voltage
Battery voltage 8.00 120
100
100
120
Battery voltage 0.10CA
0.10CA
0.8
0.8 120
120
140
140 6.00
6.00
7.00
7.00 0.05CA

(%) (%)
(%) (%)
Dimensions Width 34mm 140 Charge
Chargequantity
quantity
(to(to
discharge
discharge
quantity)
quantity) 7.00 0.05CA

(CA) (CA)
(CA) (CA)
100 0.05CA
0.25CA
0.25CA

(V) (V)
(V) (V)
5 100 0.10CA
(h)

80
100 80 0.10CA
0.8 100
0.8 100
120
120 5.00
5.00
6.00
6.00 0.10CA
0.50CA
0.50CA

(%) (%)
(%) (%)
Height 100mm Discharge
Discharge

quantity
quantity
ŚŚ
0.6 120 6.00

voltage
voltage
25°C 0.8
0.6 Charge quantity
Charge (to(to
—quantity
discharge quantity)
discharge quantity)

(%)
3 Charge —quantity
100%
100% (to(0.05CA*20H)
discharge
(0.05CA*20H) quantity) 0.25CA

current
current
—— 0.25CA

(CA)
8080 0.25CA

(V)
8080 4.00
4.00

Capacity
Capacity
Approx. mass 1.30kg 100 5.00
Duration of discharge

100
100 Ś— —
—50%
50%(0.05CA*10H)
—Discharge (0.05CA*10H) 5.00
5.00 80
6060 0.50CA
1.00CA
1.00CA
0.50CA

quantity
Discharge 0.50CA

quantity

voltage
ŚŚ

(%)
voltage
Discharge

quantity
0.6
0.6

voltage
—ś 100% (0.05CA*20H) 2.00CA
2.00CA

current
Terminal Faston 187/250 0.6 —Charge
— — Charge
100% (0.05CA*20H)

current
ś —
0.4
0.4 6060 100% (0.05CA*20H) 3.00
3.00

current
80 4.00

Capacity

80 4.00

Capacity
6060

Battery
Battery
80 ȼ— 4.00 1.00CA

Capacity
50% (0.05CA*10H) 3.00CA
3.00CA

Charge
Charge


—ȼ—
—50%50%
Charge
Charge (0.05CA*10H)
voltage:
voltage:
(0.05CA*10H)7.35V
7.35V
(2.45V/cell)
(2.45V/cell) 60
4040 1.00CA
1.00CA

Charge
Charge
20 hour rate 7.2Ah 2.00CA
60 0.4
0.4 40
6040
60
śśCharge
Charge
ś Charge
Charge
Charge current:
current:
0.40CA
0.40CA 2.00
2.00
3.00
3.00
2.00CA
2.00CA
0.4 60 3.00

Battery
3.00CA

Battery
Charge
0°C Charge voltage: 7.35V (2.45V/cell) 3.00CA

Charge
10 hour rate 6.6Ah 0.2
0.2

Battery
ȼ Charge
Temperature: voltage:
Temperature: 25°C 7.35V
25°C(77°F) (2.45V/cell)
(77°F) 4040 3.00CA

Charge
Capacity Ŝ
ȼŜȼCharge voltage: 7.35V (2.45V/cell)

Charge
40

Charge
2020

Charge
(25°C) 20
4020
40 Charge current:
Charge
Charge 0.40CA
current:
current: 0.40CA
0.40CA 1.00
1.00
2.00
2.00
3 hour rate 5.8Ah 30 40 2.00
0.2
0.2 Ŝ Temperature:
Charge
Charge 25°C
current
current
Temperature: 25°C(77°F)
(77°F)
00.2
ŜŜTemperature: 25°C (77°F) 2020
1 hour rate 4.9Ah 0 20020
20 0 0.00
0.00
1.00
1.00
1.00 2000
00 22 4 4 Charge
6 6 current
Charge
Charge 8 8 1010 1212
current
current -15
-15 00 1515 3030 4545
Fully charged battery 000 000 0.00
0.00
0.00 00 0
(min.)

Impedance 11mΩ 10 -15°C Charge


Chargetime
time(h)(h) Batterytemperature
Battery temperature (°C)
(°C)
(25°C) 00 0 22 2 44 4 66 6 88 8 10 1010 12
1212 -15
-15-15 00 0 151515 303030 454545
40°C 102% Charge
Charge
Charge time
time
time (h)
(h)(h) Battery
Battery
Battery temperature
temperature
temperature (°C)
(°C)(°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
10.00 CHARACTERISTICS
10.00
After 3 month 91% 1 10.00
10.00
10.00
Self-discharge 0.1 0.3 1 3 10 30 100
After 6 month 82%
(25°C)
After 12 month 64% Discharge current (A) 7.50
7.50

(V) (V)
(V)
7.50
7.50
7.50

voltage
voltage
(V)
(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
voltage
voltage
5.00
5.00 0.360A
0.360A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 1.80A
1.80A

Terminal
Terminal
7.20A
7.20A
4.80V 215 167 110 83.5 67.1 49.2 36.0 28.2 22.3 17.3 12.3 9.60 7.69 6.40 4.19 2.30 5.00
5.00
5.00 21.6A
21.6A 0.360A
0.360A
1.80A
1.80A
1.80A 0.360A

Terminal
Terminal
Terminal
7.20A
7.20A
7.20A
4.95V 202 143 93.5 79.5 64.8 48.2 35.8 27.6 21.9 17.2 12.1 9.53 7.63 6.27 4.18 2.29 21.6A
21.6A
21.6A
2.50
2.50
5.10V 189 136 91.0 75.5 63.0 47.2 34.3 26.8 20.7 16.3 11.8 9.33 7.32 6.11 4.00 2.21
2.50
2.50
2.50
5.25V 172 124 86.8 72.2 60.2 45.4 33.4 26.2 19.9 15.8 11.5 9.15 7.27 6.05 3.98 2.14
5.40V 154 112 82.0 69.1 57.7 43.6 31.3 24.2 18.6 14.0 10.7 8.46 6.67 5.60 3.71 2.07
0.00
0.00
00 11 22 44 6 6 8 8 1010 2020 4040 6060 22 44 6 6 8 8 1010 2020 4040
0.00
0.00 (min.)
(min.)
AMPERE TABLE (25°C) (Ampere/battery) 0.000
00 11 1 22 2 44 4 6
6 6 88 8101010 20
2020 40
4040 606060 22 44 6 6 8(h) (h)
10 2020 4040
2 4 6 8 8 1010 20 40
(min.)
(min.) (h)(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.) Duration
Durationofofdischarge
discharge (h)
4.80V 38.9 30.6 19.9 14.8 12.3 9.10 6.40 5.10 3.50 2.70 2.00 1.53 1.26 1.02 0.670 0.363 Duration
Duration ofofdischarge
discharge
Duration of discharge
4.95V 36.1 28.7 19.5 14.7 12.1 9.00 6.36 5.05 3.43 2.68 1.99 1.52 1.25 1.01 0.667 0.362
5.10V 34.2 26.9 19.0 14.4 11.9 8.90 6.30 5.00 3.36 2.61 1.97 1.51 1.24 1.00 0.660 0.361
5.25V 31.4 24.1 17.6 13.4 11.3 8.70 6.20 4.90 3.29 2.52 1.94 1.50 1.23 0.988 0.657 0.360
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
5.40V 29.0 22.3 15.7 12.5 11.0 8.40 6.10 4.80 3.20 2.40 1.90 1.48 1.20 0.972 0.650 0.358 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

44 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V067R2P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V067R2P. 45
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R0612P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R0612P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type
0.600A - 2.40A - 6.00A - 12.0A - 24.0A -
DIMENSIONS (MM) 4.75 Control voltage: 7.25V - 7.45V Discharge current
Cycle use 2.40A 6.00A 12.0A 24.0A 36.0A
Initial current: 4.80A or smaller
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

6.35

3.2
CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
+1.5 (187)
+1.0
50 -0.5 151 -0.5 120
120 120
120
(130.3) 6.35

(6)
(16) 120
120 120
120
120
100
100 120
100
100

(%)
(%) (%)
4.5
100
100 100
100

ratio
ratioratio
Capacity retention ratio (%)
100
80
80 100

(%)
80
80

(%)
(%) (%)
5°C

+1.5
5°C

94 -0.5

ratio
8080

retention
retention
8080
6080 80

Capacity
Capacity
60

(%)
60
60 (41°F)
(41°F)

Capacity(%)
5°C
5°C5°C

retention
Discharge
Discharge Discharge
Discharge Discharge
Discharge

retention
Capacity
6060 6060 (41°F)
(41°F)

Capacity
(250)
4060
40 depth
depth100%
100% depth
depth 50%
50% depth
depth30%
30% 60
40
40 40°C
40°C 30°C
30°C 25°C
25°C (41°F)
Discharge
Discharge Discharge
Discharge Discharge
Discharge

(0.3)
Discharge Discharge Discharge

Capacity
Capacity
4040 (104°F)
(104°F)
40°C
40°C (86°F)
(86°F)
30°C30°C (77°F)
(77°F)
25°C
depth 100%
depth 100% depth depth 50%50% depth 30%
depth 30% 40
4040 40°C 30°C 25°C
2040
20 depth 100%
Ambientdepth 50%
Ambienttemperature
temperature depth 30% 25°C

Capacity
20
20 (104°F) (86°F)

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
(77°F)
(49.2) (150.2) 25°C
25°C(77°F)
(77°F)
2020 Ambient
Ambient temperature
temperature 20
0020 Ambient temperature 2020
Contents indicated (including the recycle marking, etc.) 25°C (77°F)
25°C (77°F) 00
25°C (77°F)
are subject to change without notice. Battery case resin: standard (UL94 HB) 00
0 0 0 400
400 800
800 1,200
1,200 00 0 00 22 44 66 88 10 10 1212 14 14 1616 18
18 20 20
0 0 Number
400 of
Number
400
400 ofcycles
cycles(times)
(times)
800800
800 1,200
1,200
1,200 00 0 22 2 44 4 6Storage
Storage
8 period
period
10 12(mth.)
(mth.)
14 16 18 20
6 6 8 8 1010 12 12 14 14 16 1618 1820 20
Number
Number
Numberofof
cycles
ofcycles(times)
cycles (times)
(times) Storage period
Storage
Storage (mth.)
period
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-R0612P*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 6V
20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
160
160 8.00
8.00 120
120
Nominal capacity (20 hour rate) 12.0Ah Battery
Batteryvoltage
voltage
40°C
160
160
140
140 8.00
8.00
8.00
7.00
7.00 120
120
120
Length 151mm 10 Battery
Batteryvoltage
Battery voltage
voltage
100
0.05CA
0.05CA
100 0.10CA
0.10CA
Dimensions Width 50mm 0.8
0.8 140
140
120
120 7.00
7.00
7.00
6.00
6.00 0.05CA
0.05CA
0.05CA

(%)
(%) (%)
Charge
Chargequantity
quantity(to
(todischarge
dischargequantity)
quantity) 100
100
100

(CA)
5

(CA)(CA)
0.10CA
0.10CA
0.10CA
0.25CA

(V)
0.25CA
(h)

(V) (V)
Height 100mm 0.80.8 120
120
100
100 6.00
6.00
6.00
5.00
5.00 80
80 0.50CA
0.50CA

(%)
(%)

(%) (%)
quantity
Discharge

quantity (%)
quantity
Charge
Charge
Charge
ŚŚ Discharge
quantity (to(to
quantity
quantity discharge
(todischarge
dischargequantity)
quantity)
quantity)
25°C

voltage
voltage
(CA)
current (CA)
3 0.6
0.6 0.25CA
0.25CA

(V)
0.25CA

Battery voltage (V)


—— 100%
100%(0.05CA*20H)

current
(0.05CA*20H) 80
8080

current
Approx. mass 1.95kg 100
100 — — 5.00
5.00
Duration of discharge

80 5.00
4.00 0.50CA
0.50CA
0.50CA

Capacity
80 4.00

Capacity
(%)
quantity
Discharge
Discharge

Capacity (%)
Charge quantity
Ś— Ś
—Ś Discharge
50%
50% (0.05CA*10H)
(0.05CA*10H) 60
60 1.00CA
1.00CA

voltage
voltage
0.60.6 ——
—— — 100%
100% (0.05CA*20H)
(0.05CA*20H)

current
Terminal Faston 187/250 — 100% (0.05CA*20H)

Charge current
— —
śCharge
Charge 2.00CA
2.00CA
80 4.00

Capacity
80 4.00

Capacity
ś
0.4
0.4 60
60 ——
— —50%
— 50%
50% (0.05CA*10H)
(0.05CA*10H)
(0.05CA*10H) 4.00
3.00
3.00 6060
60 1.00CA
1.00CA
1.00CA

Battery

Battery
3.00CA

Charge
3.00CA

Charge
20 hour rate 12Ah ȼȼCharge
Chargevoltage:
voltage:7.35V
7.35V(2.45V/cell)
(2.45V/cell) 40
40 2.00CA

Charge
2.00CA

Charge
60 śś ś Charge
Charge
Charge 2.00CA
0.40.4 60
4060
4060 Charge
Chargecurrent:
current:0.40CA
0.40CA 3.00
3.00
3.00
2.00
2.00

Battery
Battery
3.00CA
3.00CA

Charge
0°C Charge voltage: 7.35V (2.45V/cell) 3.00CA

Charge
Capacity 10 hour rate 11Ah ȼȼ Charge
ȼ Chargevoltage: 7.35V
voltage: (2.45V/cell)
7.35V (2.45V/cell) 4040
40
0.2

Charge
0.2

Charge
ŜŜTemperature:
Temperature: 25°C
25°C (77°F)
(77°F)
40 Charge
Charge
Charge current:
current: 0.40CA
0.40CA
current: 0.40CA 2.00 20
20
(25°C) 3 hour rate 9.3Ah 30 40
2040
20 2.00
2.00
1.00
1.00
0.2
0.20.2 ŜŜ Ŝ Temperature:
Temperature:
Temperature: 25°C
25°C
25°C (77°F)
(77°F)
(77°F)
Charge
Chargecurrent
current 2020
20
1 hour rate 8.5Ah 00 20020
20
0 1.00
1.00
1.00
0.00
0.00 00
Charge
Charge current
current
Charge current
Impedance
Fully charged battery 0 00 0 00 00 22 44 66 88 10
10 12 0.00
12 0.00
0.00 00-15
0-15 00 15
15 30
30 45
45
9mΩ -15°C
(min.)

(25°C) 10 Charge
44 6time (h)
0 00 2 22 4Charge 6time (h)
6 8 88 1010 12
10 1212 -15
-15-15 00 0Battery
Batterytemperature
15
15 15 30(°C)
temperature
30 (°C)
30 45
4545
40°C 102% Charge
Charge
Charge time
time (h)(h)
time (h) Battery
Battery temperature
temperature (°C)
(°C)
Battery temperature (°C)
5
Temperature dependency 25°C 100%
of capacity (20 hour rate) 3
0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
10.00
10.00
After 3 month 91% 1 10.00
10.00
10.00
Self-discharge 0.1 0.3 1 3 10 30 100
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 7.50
7.50
7.50

(V) (V)(V)
7.50
7.50

voltage(V)(V)
voltage
voltage
WATT TABLE (25°C) (Wattage/battery)

voltage
Terminalvoltage
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 5.00
5.00 0.600A
0.600A
3.00A
3.00A
5.00

Terminal
12.0A 0.600A

Terminal
4.80V 340 279 192 149 124 91.3 68.7 52.4 35.1 27.2 19.0 14.4 12.0 10.9 6.66 3.61 5.00
5.00 36.0A 12.0A 3.00A
36.0A 3.00A
3.00A 0.600A
0.600A
12.0A
36.0A
Terminal
12.0A

Terminal
4.95V 325 269 186 144 121 88.3 67.5 51.8 35.0 27.1 18.9 14.4 12.0 10.9 6.66 3.61 36.0A 12.0A
36.0A
5.10V 304 253 181 141 118 87.2 66.9 51.2 34.5 26.9 18.7 14.4 12.0 10.8 6.60 3.61 2.50
2.50
2.50
5.25V 278 237 171 136 115 86.0 66.3 50.1 34.2 26.6 18.4 14.3 12.0 10.8 6.60 3.60 2.50
2.50
5.40V 247 217 161 131 113 83.1 61.6 48.9 33.1 26.0 18.1 14.2 11.9 10.7 6.54 3.59
0.00
0.00
0.0000 11 22 44 66 88 1010 20
20 40
40 60
60 22 44 66 88 10 10 20
20 40
40
(Ampere/battery) 0.00
0.00 0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
AMPERE TABLE (25°C) 0 0 1 1 2 2 4 4 6 6(min.)
(min.)
8 81010 2020 4040 6060 2 2 4 4 6 6 (h)
(h)
8 81010 2020 4040
(min.) (h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.)
(min.) (h)(h)
Duration
Durationof
ofdischarge
discharge
4.80V 61.1 50.1 34.3 25.9 21.3 15.6 11.7 8.90 5.95 4.60 3.20 2.41 2.01 1.81 1.11 0.602 Duration of discharge
Duration of of
Duration discharge
discharge
4.95V 58.4 48.2 33.3 25.0 20.8 15.1 11.5 8.80 5.92 4.58 3.18 2.41 2.01 1.81 1.11 0.602
5.10V 54.6 45.4 32.4 24.5 20.3 14.9 11.4 8.70 5.85 4.55 3.15 2.41 2.00 1.80 1.10 0.601
5.25V 50.0 42.6 30.6 23.6 19.9 14.7 11.3 8.50 5.80 4.50 3.10 2.40 2.00 1.80 1.10 0.600
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
5.40V 44.5 38.9 28.7 22.7 19.4 14.2 10.5 8.30 5.60 4.40 3.05 2.38 1.99 1.79 1.09 0.598 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

46 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V0612P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V0612P. 47
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R121R3P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R121R3P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT. G196049
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.065A - 0.26A - 0.65A - 1.3A - 2.6A -
DIMENSIONS (MM) Terminal type Control voltage: 14.5V - 14.9V Discharge current
Cycle use 0.26A 0.65A 1.3A 2.6A 3.9A
Initial current: 0.52A or smaller
4.75 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

6.35

3.2
CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT

(187) 120
120 120
120

(4.75)
47.5±1 97±1 120
120 120
120
100
100 120
120
100
100

(%)
(%) (%)
(30.8) (46.44)

ratio
ratio
100
100 100
100 100
100
80

(%)
80 80

ratio(%)
80

(%)
(%) (%)
5°C
5°C

retention
ratio
retention
ratio
80

Capacity
80

Capacity
80
80
60
60 80
80
60
60 (41°F)
(41°F)

(%)
(%)
50±1
5°C
5°C
5°C

retention
Discharge Discharge Discharge

retention
Discharge Discharge Discharge

retention
Capacity
Capacity
Capacity
60
60 60
60
60 40°C
40°C 30°C
30°C 25°C (41°F)
25°C (41°F)
(41°F)
60
40
40 depth
depth100%
100% depth
depth50%
50% depth
depth30%
30% 40
40

Capacity
Discharge Discharge Discharge

Capacity
Discharge
Discharge Discharge
Discharge Discharge
Discharge (104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
40 depth 100% depth 50% depth 30% 40 40°C
40°C
40°C 30°C
30°C
30°C 25°C
25°C
25°C
40
40
20 depth
depth 100%
100%
Ambient depth
depth 50%
50%
Ambienttemperature
temperature depth
depth 30%
30% 40
40
20
20

Capacity
(47) (96.5) 20 (104°F) (86°F)

Capacity
(77°F)

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
25°C
25°C(77°F)
(77°F)
20 Ambient
Ambient temperature 20
20
20
Ambient temperature

(0.3)
20
20
00 temperature 00
Contents indicated (including the recycle marking, etc.) 25°C(77°F)
25°C (77°F)
00 25°C
400 (77°F)
400 800
800 1,200
1,200 00 22 44 66 88 10 10 1212 1414 16
16 18
18 20
20
are subject to change without notice. Battery case resin: standard (UL94 HB) 000 Number 000
Numberofofcycles
cycles(times)
(times) Storage
Storage period
period(mth.)
(mth.)
000 400
400
400 800
800
800 1,200
1,200
1,200 000 222 444 666 8
88 10 10
10 12 12
12 14 14
14 1616
16 1818
18 2020
20
Numberof
Number
Number ofcycles
of cycles(times)
cycles (times)
(times) Storageperiod
Storage period(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Storage period (mth.)

Name LC-R121R3PG*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE


30
Nominal voltage 6V
20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
160
160 16.0
16.0 120
120
Nominal capacity (20 hour rate) 1.3Ah 40°C Battery
Batteryvoltage
voltage
140
140
160
160 14.0
14.0
16.0
16.0 120 0.05CA
0.05CA
Length 97mm 10 Battery voltage 120
120
100
100
Battery
Battery voltage
voltage 0.10CA
0.10CA
0.8
0.8 120
140
120 12.0
14.0
12.0

(%)
(%) (%)
Dimensions Width 47.5mm 140 14.0 0.05CA

(CA)
Charge
Chargequantity
quantity(to
(todischarge
dischargequantity) 0.05CA

(CA)(CA)
quantity) 100 0.05CA
0.25C
0.25CAA

(V)
5 100 0.10CA

(V) (V)
100
(h)

0.8 80
80 0.10CA
0.10CA
0.50CA
100 10.0

(%)
quantity
0.8 100
120 10.0
12.0 0.50CA

(%) (%)
25°C

quantity
Height 55mm 0.6 120 ŚŚDischarge
Discharge 12.0

voltage
0.6

(%)

voltage
Charge—quantity(to
(todischarge
discharge quantity)

current
0.25CA
AA

current
Charge quantity discharge quantity)

(CA)
3 Charge— — 100%
quantity
— (0.05CA*20H)
100%(to (0.05CA*20H) quantity) 0.25C
80 0.25C

(V)

Capacity
Capacity
Approx. mass 0.55kg 80 8.0 80
80 0.50CA
Duration of discharge

80
100 8.0
10.0

quantity
100 —— 50%
50%(0.05CA*10H)
Discharge
(0.05CA*10H) 10.0 60
60 1.00CA
0.50CA
1.00CA
0.50CA

(%)
Ś

quantity
0.6 Ś— Discharge

voltage
0.6
Ś Discharge

current

voltage

— 100%
Charge (0.05CA*20H) 2.00CA
2.00CA

current
Terminal Faston 187 0.4
0.4 ś —
— Charge
ś
— 100%
100% (0.05CA*20H)
(0.05CA*20H)

Capacity
60
60
80 — 6.0
6.0
8.0

Capacity
60

Charge
80 — 8.0 1.00CA

Charge

Battery
50% (0.05CA*10H) 3.00CA

Battery
ȼ———
— Charge
50% voltage:
voltage:14.7V
50% (0.05CA*10H)
Charge(0.05CA*10H) 14.7V(2.45V/cell)
(2.45V/cell) 60
60
40 3.00CA
1.00CA
1.00CA

Charge
ȼ 40

Charge

20 hour rate 1.3Ah ś Chargecurrent: 0.40CA 2.00CA
60 0°C 0.4
0.4 40
60
40 śś Charge
Charge current: 0.40CA
Charge 4.0
6.0
4.0 2.00CA
2.00CA
60 6.0

Charge

Battery
0.2
0.2 Charge voltage: 14.7V (2.45V/cell) 3.00CA

Charge
ȼ 40 3.00CA

Battery
10 hour rate

Charge
Capacity 1.2Ah Ŝ
ȼȼŜTemperature:
Charge
Charge voltage:
Temperature:
voltage:25°C
25°C(77°F)
14.7V
14.7V (2.45V/cell)
(77°F)
(2.45V/cell) 40
40 3.00CA

Charge
20 Charge current:0.40CA
0.40CA 2.0 20
20
(25°C) 20
40
40 Charge
Charge current:
current: 0.40CA 2.0
4.0
4.0
3 hour rate 1.1Ah 30 0.2
0.2 Charge
Chargecurrent
Ŝ Temperature: 25°C (77°F)
current
00 ŜŜ Temperature:
Temperature: 25°C
25°C (77°F)
(77°F) 20
1 hour rate 0.9Ah 2000
20 0.0
0.0
2.0
2.0 20
20
00
Chargecurrent
current
00 22 44 Charge
66 current
Charge 88 10 10 12
12 -15 00 15 30 45
Fully charged battery -15°C 00 00 0.0
0.0 000
-15 15 30 45
Impedance Charge time
time(h)
(min.)

90mΩ 10 Charge (h) Battery


Batterytemperature
temperature(°C)
(°C)
(25°C) 00 22 44 66 88 10
10 12
12 -15
-15
-15 000 1515
15 30
30
30 45
45
45
40°C 102% Chargetime
Charge time(h)
(h) Battery
Battery temperature
temperature (°C)
(°C)
Battery temperature (°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
20.0
20.0
Self-discharge
After 6 month 82%
0.01 0.03 0.1 0.3 1 3 10
(25°C) Discharge current (A) 15.0
15.0
After 12 month 64%

(V)
(V) (V)
15.0
15.0
15.0

voltage
voltage
(V)
WATT TABLE (25°C) (Wattage/battery)

(V)
10.0
10.0 0.0650A
0.0650A

voltage
0.325A
0.325A

voltage
voltage
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 1.30A
1.30A

Terminal
Terminal
10.0
10.0
10.0 3.90A
3.90A 0.325A 0.0650A
9.6V 78.1 61.6 40.2 30.7 25.8 19.2 13.6 10.8 7.49 5.73 4.32 3.30 2.73 2.22 1.46 0.787 0.325A
0.325A 0.0650A
0.0650A
1.30A
1.30A

Terminal
3.90A 1.30A

Terminal
Terminal
9.9V 72.5 57.8 39.4 30.5 25.3 19.0 13.5 10.7 7.34 5.68 4.30 3.28 2.70 2.21 1.45 0.784 5.0
5.0 3.90A
3.90A
10.2V 66.9 54.2 38.4 29.9 24.9 18.8 13.4 10.6 7.19 5.54 4.25 3.26 2.68 2.19 1.44 0.782 5.0
5.0
5.0
10.5V 59.4 48.5 35.6 27.8 23.7 18.4 13.1 10.4 7.04 5.34 4.19 3.25 2.66 2.17 1.43 0.780
10.8V 50.2 42.9 31.7 26.0 23.0 17.7 12.9 10.2 6.82 5.13 4.08 3.24 2.60 2.16 1.41 0.758 0.0
0.0
00 11 22 44 66 88 1010 20
20 40
40 60
60 22 44 66 88 10 10 20
20 40
40
0.0
0.0
0.0 (min.)
(min.) (h)
(h)
(Ampere/battery) 000 111 222 444 666 8
88 1010
10 20
20
20 40
40
40 60
6060 222 444 666 8
88 10 10
10 20
20
20 40
40
40
AMPERE TABLE (25°C) (min.) Duration (h)
(min.)
(min.) Durationofofdischarge
discharge (h)
(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Durationof
Duration
Duration ofdischarge
of discharge
discharge
9.6V 7.02 5.53 3.59 2.67 2.22 1.64 1.16 0.921 0.634 0.484 0.363 0.276 0.228 0.185 0.122 0.0655
9.9V 6.52 5.18 3.52 2.65 2.18 1.63 1.15 0.912 0.621 0.480 0.361 0.274 0.226 0.184 0.121 0.0654
10.2V 6.01 4.86 3.43 2.60 2.15 1.61 1.14 0.903 0.609 0.468 0.358 0.273 0.224 0.183 0.120 0.0652
10.5V 5.34 4.35 3.18 2.42 2.04 1.57 1.12 0.885 0.596 0.451 0.352 0.272 0.222 0.182 0.119 0.0650
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 4.51 3.85 2.83 2.26 1.99 1.52 1.10 0.867 0.578 0.433 0.343 0.271 0.217 0.181 0.117 0.0632 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

48 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V121R3PG. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V121R3PG. 49
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R122R2P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R122R2P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT. G188151
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.110A - 0.440A - 1.10A - 2.00A - 4.40A -
DIMENSIONS (MM) Terminal type Control voltage: 14.5V - 14.9V Discharge current
Cycle use 0.440A 1.10A 2.20A 4.40A 6.60A
4.75 Initial current: 0.88A or smaller
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

6.35

3.2
CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
(187)
120
120 120
120
+1.5
177 -0.5 34±1 120 120
120
100
100 120
100
100

(%)
(10.1)

(%) (%)
(172.8)

(6)

2.8
100

ratio
100 100

ratioratio
100

(%)
(%)
80
80 80
80

(%)
(%) (%)
5°C
5°C

ratio
ratio
retention
retention
80
80 80
80

Capacity
60 (41°F)

Capacity
60 60
60 (41°F)

(%)
60±1

(%)
5°C
5°C

retention
retention
Discharge
Discharge Discharge
Discharge Discharge
Discharge

retention
Capacity
60 (41°F)

Capacity
60

Capacity
60
40 depth 100% depth 50% depth 30% 60 40°C
40°C 30°C
30°C 25°C
25°C (41°F)
40 depth 100% depth 50% depth 30% 40
40
Discharge
Discharge Discharge
Discharge Discharge
Discharge

Capacity
(104°F) (86°F)

Capacity
(104°F)
40°C (86°F)
30°C (77°F)
(77°F)
40
40 depth 100% depth 50% depth 30% 40 40°C 30°C 25°C
25°C
20
20 depth 100%
Ambientdepth
Ambient 50%
temperature
temperature depth 30% 40
20
(176) (33.5) 20

Capacity
(104°F) (86°F)

Capacity
(104°F) (86°F) (77°F)

Capacity
(77°F)
20 25°C
25°C (77°F)
(77°F)
Ambient temperature

0.3
20
00 Ambient temperature 20
20
00
Contents indicated (including the recycle marking, etc.) 25°C(77°F)
25°C (77°F)
are subject to change without notice. Battery case resin: standard (UL94 HB) 00 00 400
400 800
800 1,200
1,200
00
00 22 44 66 88 1010 1212 14 14 16
16 18
18 20
20
Number
Numberof ofcycles
cycles(times)
(times) Storage
Storageperiod
period (mth.)
(mth.)14 16 18 20
00 400
400 800
800 1,200
1,200 00 22 44 66 88 10 10 12 12 14 16 18 20
Numberofofcycles
Number cycles(times)
(times) Storageperiod
Storage period(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-R122R2PG*1 30 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
Nominal voltage 12V 20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
40°C 160
160 Battery
16.0
16.0 120
120
Nominal capacity (20 hour rate) 2.2Ah Batteryvoltage
voltage
10 160
140
160
140 Batteryvoltage
voltage
16.0
14.0
16.0
14.0 120
120 0.05CA
0.05CA
Length 177mm Battery 100
100 0.10CA
0.10CA
Dimensions Width 34mm 0.8
0.8 140
120
120
140 14.0
12.0
12.0
14.0 0.05CA

(CA)
0.05CA

(%)
(CA)(CA)

(%) (%)
5 Charge
Chargequantity
quantity(to
(todischarge
dischargequantity)
quantity) 100
(h)

100

(V)
0.25CA
0.10CA

(V) (V)
80
80 0.25CA
0.10CA
Height 66mm 0.8
0.8 120
100
100
120 ŚŚ Discharge
Discharge 12.0
10.0
10.0
12.0 0.50CA
0.50CA

quantity

Capacity(%)
(CA)

quantity

Capacity(%)
(%)
0.6

(CA)

voltage
0.6 Charge quantity(to(todischarge
dischargequantity)
quantity)

(%)

voltage
current
3

current
25°C Charge
— quantity
—100%
100%(0.05CA*20H) 0.25CA

(V)
(0.05CA*20H)

(V)
— 0.25CA
Duration of discharge

Approx. mass 0.80kg — 80


100
80
80
100 —
Ś Discharge
—50% (0.05CA*10H) 10.0
8.0
8.0
10.0 80
60 0.50CA
1.00CA
0.50CA
1.00CA
60

quantity
50% (0.05CA*10H)

Capacity(%)
Ś

quantity
— Discharge

Capacity(%)
0.6 Ś —

voltage
quantity

Capacity(%)
voltage
current
0.6

current

voltage
current
Terminal Faston 187 —Charge
—— 100%(0.05CA*20H)
100% (0.05CA*20H)
0.4
0.4 ś—

ś Charge 2.00CA
2.00CA
60
80
60
80 —50%
—— 50%(0.05CA*10H)
(0.05CA*10H) 6.0
8.0
6.0
8.0 60
60 1.00CA

Battery
— 1.00CA
3.00CA

Battery
3.00CA

Charge
Charge voltage:
voltage:14.7V
14.7V(2.45V/cell)

Charge

Charge
Charge (2.45V/cell)

Charge
ȼȼ
20 hour rate 2.2Ah 60 Charge 40
40 2.00CA
0°C 0.4
0.4 60
40
40
śś Charge
ś Chargecurrent:
current:0.40CA
0.40CA 6.0
4.0
4.0 2.00CA
60 6.0

Battery
3.00CA

Battery
0.2

Charge
Charge voltage: 14.7V (2.45V/cell)

Charge

Battery
10 hour rate 2.0Ah 0.2 3.00CA

Charge

Charge
ȼȼ Charge

Charge
voltage: 14.7V (2.45V/cell) 40

Charge
Capacity ȼ
ŜŜ Temperature:
Temperature:25°C 25°C(77°F)
(77°F) 40
40
20
20 Chargecurrent:
Charge current:0.40CA
0.40CA 4.0
2.0
2.0 20
20
(25°C) 3 hour rate 1.8Ah 30 0.2 40 4.0
0.2 Ŝ Temperature:
ŜŜ Temperature:
Charge 25°C(77°F)
25°C
Chargecurrent
current
(77°F)
1 hour rate 1.5Ah 00 20
00 2.0
0.0
0.0 20
20
20 2.0 00
Charge current
Fully charged battery 00 00 00 22 44 Charge
66 current
88 10
10 12
12 0.0
0.0 -15
-15 00 15
15 3030 45
45
(min.)

Impedance 70mΩ 10 Charge


Chargetime
time(h)(h) 00 Battery
(25°C) Batterytemperature
temperature(°C)
(°C)
-15°C 00 22 44 66 88 10 10 12
12 -15
-15 00 15
15 3030 45
45
40°C 102% Chargetime
Charge time(h)(h) Batterytemperature
Battery temperature(°C)
(°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
20.0
20.0
After 3 month 91% 1
0.01 0.03 0.1 0.3 1 3 10 20.0
20.0
Self-discharge
After 6 month 82%
(25°C)
After 12 month 64% Discharge current (A) 15.0
15.0

(V)
(V) (V)
15.0
15.0

voltage
voltage
(V)
(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
10.0

voltage
10.0

voltage
0.550A
0.550A 0.110A
0.110A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
2.20A

Terminal
2.20A

Terminal
10.0
10.0 6.60A
6.60A 0.110A
9.6V 132 104 68.1 52.0 43.6 32.5 23.0 18.4 12.6 9.77 7.27 5.59 4.61 3.71 2.46 1.33 0.550A
0.550A 0.110A
2.20A

Terminal
Terminal
2.20A
Terminal
9.9V 123 97.8 66.7 51.7 42.9 32.2 22.8 18.2 12.4 9.70 7.24 5.55 4.58 3.69 2.45 1.33 6.60A
6.60A
5.0
5.0
10.2V 113 91.6 65.0 50.6 42.2 31.8 22.6 18.0 12.1 9.44 7.16 5.51 4.54 3.66 2.42 1.32
5.0
5.0
10.5V 101 82.1 60.2 47.1 40.1 31.1 22.2 17.6 11.9 9.12 7.05 5.48 4.50 3.62 2.41 1.32
10.8V 84.9 72.6 53.7 43.9 39.0 30.0 21.9 17.3 11.5 8.68 6.91 5.40 4.39 3.56 2.38 1.31 0.0
0.0
00 11 22 33 55 77 10
10 20
20 40
40 60
60 22 44 66 88 10 10 20
20 40
40
0.0
0.0 (min.)
(min.) (h)
(h)
AMPERE TABLE (25°C) (Ampere/battery) 00 11 22 33 55 77 10
10 20
20 40
40 60
60 22 44 66 88 1010 20
20 40
40
(min.)
(min.) Duration
Durationof
ofdischarge
discharge (h)
(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
9.6V 11.9 9.35 6.08 4.52 3.76 2.78 1.96 1.56 1.07 0.825 0.611 0.468 0.385 0.309 0.205 0.111 Durationofofdischarge
Duration discharge
9.9V 11.0 8.77 5.96 4.49 3.70 2.75 1.94 1.55 1.05 0.819 0.608 0.464 0.382 0.308 0.204 0.111
10.2V 10.2 8.22 5.81 4.40 3.64 2.72 1.93 1.53 1.03 0.798 0.602 0.461 0.379 0.306 0.202 0.110
10.5V 9.04 7.36 5.38 4.09 3.45 2.66 1.89 1.50 1.01 0.770 0.593 0.458 0.376 0.302 0.201 0.110
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 7.64 6.51 4.80 3.82 3.36 2.57 1.86 1.47 0.978 0.733 0.581 0.452 0.367 0.297 0.199 0.109 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

50 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V122R2PG. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V122R2PG. 51
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R123R4P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R123R4P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT. G191053
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type 0.170A - 0.680A - 1.70A - 3.40A - 6.80A -
DIMENSIONS (MM) Control voltage: 14.5V - 14.9V Discharge current
4.75 Cycle use 0.680A 1.70A 3.40A 6.80A 10.2A
Initial current: 1.36A or smaller
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

6.35

3.2
CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
(187)
120
120 120
120
+1.5
134 -0.5 67±1 120
120
120 120
120
120
100 100

(%) (%)
100 100

(%) (%)
(64.9) (57)
100 100

(6)
100

ratioratio
100

(2.8)
(53.2)

ratioratio
100
80 100
80
80 80

(%) (%)
(%) (%)
5°C
5°C

retention
80
80 80

retention
80 80
80

Capacity
60 60 (41°F)

Capacity
60 60 (41°F)
5°C
5°C
5°C

retention
60±1
Discharge Discharge Discharge

retention
Discharge Discharge Discharge

Capacity
60
60 60
60 (41°F)
(41°F)

Capacity
60
40 depth 100%
100% depth 50%
50% depth 30%
30% 60
40 40°C
40°C 30°C
30°C 25°C (41°F)
40 depth
Discharge
Discharge depth
Discharge
Discharge depth
Discharge
Discharge 40 25°C
Discharge Discharge Discharge

Capacity
Capacity
(104°F)
(104°F)
40°C (86°F)
(86°F)
30°C (77°F)
(77°F)
25°C
40
40
40 depth
depth 100%
100% depth
depth 50%
50% depth
depth 30%
30% 40
40 40°C
40°C 30°C
30°C 25°C
25°C
20 depth 100% depth 50%
Ambient temperature
temperature depth 30% 40
20
20

Capacity
Ambient 20 (104°F)
(104°F) (86°F)
(86°F) (77°F)

Capacity
(104°F) (86°F) (77°F)
(77°F)
(133) (66.5) 20
20 25°C (77°F)
25°C (77°F)
Ambient
Ambient temperature 20
Ambienttemperature
(0.3)
20 temperature 20
20
00 25°C (77°F) 00
Contents indicated (including the recycle marking, etc.) 25°C
25°C(77°F)
(77°F)
000 00 400
400 800
800 1,200
1,200 000 00 22 44 66 88 1010 12 12 1414 1616 18
18 20
20
are subject to change without notice. Battery case resin: standard (UL94 HB) Number of of cycles
cycles (times)
(times)
000 Number
400
400 800
800 1,200
1,200 000 222 444 Storage
Storage period
period
666 888 10 10 (mth.)
(mth.)
12 14 16 18 20
400 800 1,200 10 12 12 1414 16
16 18
18 20
20
Number
Number
Numberof ofofcycles
cycles (times)
cycles(times)
(times) Storage
Storage period (mth.)
Storageperiod
period(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-R123R4PG*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20 CHARGE CHARACTERISTICS
160
FOR CYCLE USE 16.0
AND BY DISCHARGE CURRENT
160 Battery voltage
voltage 16.0 120
120
Nominal capacity (20 hour rate) 3.4Ah Battery
40°C 160
160
140
160
140 16.0
16.0
14.0
16.0
14.0 120
120 0.05CA
Length 134mm 10 Battery
Battery voltage
Batteryvoltage
voltage
120
100 0.05CA
100 0.10CA
0.10CA
0.8
0.8 140
140
120
140 14.0
14.0
12.0
14.0 0.05CA
0.05CA
120 12.0

(%) (%)
Dimensions Width 67mm 0.05CA

(%) (%)
Charge quantity
Charge quantity (to
(to discharge
discharge quantity)
quantity) 100
100
100 0.10CA
0.25CA
0.10CA
5

(CA) (CA)
0.25CA
(h)

0.8 80 0.10CA

(V) (V)
(CA) (CA)
0.8 120 12.0 80

(V) (V)
0.8 120
100 12.0
10.0 0.50CA

quantity
Height 66mm

(%) (%)
120
100 Discharge
Śquantity 12.0
10.0 0.50CA

quantity

(%) (%)
0.6 Charge
Ś
Charge Discharge
quantity (to
(to discharge quantity)
0.6 Charge—quantity (todischarge
dischargequantity)
quantity) 0.25CA
0.25CA

voltage
3 25°C 100% (0.05CA*20H)
(0.05CA*20H)

voltage
80 0.25CA

current

— 100% 80

current
100 10.0 80
Duration of discharge

Approx. mass 1.15kg 100


80 10.0
8.0 0.50CA

Capacity
0.50CA

quantity
100
80 Discharge 10.0
8.0

Capacity
Ś—Discharge
Ś 50% (0.05CA*10H) 60 0.50CA
1.00CA

quantity
0.6
0.6
0.6
Ś
— Discharge
— 50% (0.05CA*10H) 60 1.00CA

voltage
—— 100%
100% (0.05CA*20H)
— 100%(0.05CA*20H)

voltage

current
Terminal Faston 187 ś——Charge (0.05CA*20H) 2.00CA
0.4

current
80
80 — Charge 8.0
8.0 2.00CA

Capacity
0.4 60
60
80
ś 6.0
6.0
8.0 60

Capacity
—— 50%
50% (0.05CA*10H)
50%(0.05CA*10H) 60 1.00CA
1.00CA

Charge
— —Charge (0.05CA*10H) 60

Battery
1.00CA
3.00CA

Charge
ȼ — voltage: 14.7V
14.7V (2.45V/cell)
(2.45V/cell)

Battery
ȼ Charge voltage: 40 3.00CA

Charge
20 hour rate 3.4Ah Charge 40 2.00CA
2.00CA

Charge
0.4 śśCharge
ś
60 0.4
0.4 60
60
40
60
Chargecurrent:
Charge
Charge current: 0.40CA
0.40CA 6.0
6.0
4.0
6.0 2.00CA
40 4.0

Charge
3.00CA

Battery
Charge
ȼȼCharge voltage:
Chargevoltage: 14.7V
14.7V (2.45V/cell)
(2.45V/cell) 3.00CA

Charge
ȼ
10 hour rate 0°C 0.2 40

Battery
3.1Ah 0.2 voltage:
Temperature: 14.7V
25°C (2.45V/cell)
(77°F) 40 3.00CA

Charge
Capacity Ŝ Temperature: 25°C (77°F) 40

Charge
Ŝ
40
40
20 Charge
Charge current:
Chargecurrent: 0.40CA
current:0.40CA
0.40CA 4.0
4.0
2.0 20
20
(25°C) 3 hour rate 2.8Ah 30 0.2
0.2 40
20 Temperature: 25°C (77°F)
4.0
2.0
0.2 ŜŜTemperature:
Ŝ 25°C
Charge current
Temperature: 25°C(77°F)
current (77°F)
Charge 20
20
1 hour rate 2.3Ah 00 20
2000
20 2.0
2.0
0.0
2.0
0.0 20
Chargecurrent
Charge current 00
Charge
Fully charged battery 000 000 00 22 44 66 current
88 10
10 12 0.0
12 0.0
0.0 -15
000-15 00 15
15 30
30 45
45
(min.)

Impedance 50mΩ 10 -15°C Charge time (h) Battery temperature (°C)


(°C)
(25°C) 000 2 4
Charge6 time 8
8(h) 10 12
22 44 66 8 10
10 12
12 -15
-15
-15 000 Battery temperature
15
1515 30
3030 45
45
45
40°C 102% Charge
Charge time
time (h)
(h)
Charge time (h) Battery
Battery temperature
temperature (°C)
(°C)
Battery temperature (°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
20.0
After 3 month 91% 1 20.0
20.0
Self-discharge 0.1 0.3 1 3 10 30 100 20.0
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 15.0
15.0

(V) (V)
(V) (V)
15.0
15.0
15.0

voltage
voltage
WATT TABLE (25°C) (Wattage/battery)

voltage
10.0

voltage
10.0
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 0.850A
0.850A 0.170A
0.170A

Terminal
3.40A

Terminal
10.0
10.0 10.2A 3.40A
9.6V 204 161 105 80.4 67.4 50.3 35.5 28.4 19.6 15.0 11.3 8.63 7.13 5.80 3.81 2.06 10.0 10.2A
3.40A 0.850A
0.850A
0.850A 0.170A
0.170A
0.170A

Terminal
3.40A

Terminal
10.2A
10.2A 3.40A
9.9V 190 151 103 79.8 66.3 49.7 35.3 28.1 19.2 14.9 11.2 8.58 7.07 5.78 3.80 2.05 10.2A
5.0
5.0
10.2V 175 142 100 78.2 65.2 49.2 34.9 27.8 18.8 14.5 11.1 8.52 7.01 5.73 3.76 2.05
5.0
5.0
5.0
10.5V 155 127 93.1 72.8 61.9 48.1 34.4 27.3 18.4 14.0 11.0 8.49 6.96 5.66 3.74 2.04
10.8V 131 112 83.0 67.9 60.3 46.4 33.8 26.7 17.8 13.4 10.7 8.46 6.79 5.66 3.68 1.98 0.0
0.0
00 11 22 33 55 77 10
10 20
20 40
40 60
60 22 44 66 88 10 10 20
20 40
40
0.0
0.0
0.0 (min.) (h) 10
AMPERE TABLE (25°C) (Ampere/battery) 000 111 222 333 555 (min.)
777 1010
10 20
20
20 40
40
40 60
60
60 222 444 666 88(h) 10
8 10 20
20
20 40
40
40
(min.)
(min.)
(min.) Duration of discharge (h)
(h) (h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h Duration of discharge
9.6V 18.4 14.4 9.40 6.99 5.81 4.30 3.02 2.41 1.66 1.26 0.949 0.722 0.595 0.484 0.318 0.171 Duration
Duration ofofdischarge
Durationof discharge
discharge
9.9V 17.0 13.6 9.21 6.94 5.71 4.25 3.00 2.39 1.62 1.24 0.945 0.718 0.590 0.482 0.316 0.171
10.2V 15.7 12.7 8.97 6.80 5.62 4.20 2.97 2.36 1.59 1.22 0.935 0.713 0.586 0.478 0.313 0.170
10.5V 14.0 11.4 8.31 6.33 5.34 4.11 2.93 2.31 1.56 1.18 0.921 0.710 0.581 0.475 0.312 0.170
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 11.8 10.1 7.41 5.90 5.19 3.97 2.88 2.27 1.51 1.13 0.897 0.708 0.567 0.472 0.307 0.165 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

52 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V123R4PG. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V123R4PG. 53
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R124R5P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R124R5P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
+2 0.225A - 0.9A - 2.25A - 4.5A - 9.0A -
DIMENSIONS (MM) 4.75 Terminal type (97 -1 ) Control voltage: 14.5V - 14.9V Discharge current
Cycle use 0.9A 2.25A 4.5A 9.0A 13.5A
Initial current: 1.80A or smaller
+0.08

6.35
3.82 -0.04 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V
+2
(70 -1 )

3.2
(49) (17)
+0.08 1.93 0.67
2.76 -0.04 CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT

0.24
(6)
(187)
120 120
120 120
100
120
100
120
120 100
120
120
120
100

ratio (%)ratio (%)


4.02 xxxx
80

(%) (%)
(102 xxxx)
100

(%)
100
100
80 80
100
100
100

(%) (%)
80 5°C

ratio ratio
CapacityCapacity
60

ratio (%)
5°C
(41°F)

retention
80

Capacity
8060
80 Discharge Discharge Discharge 6080

(%)
(41°F)

retention
(%)
Discharge Discharge Discharge 8060
80
40 depth 100% depth 50% depth 30% 5°C
5°C
5°C

Capacity
60 40°C 30°C 25°C

Capacity
6040
60 depth 100% depth 50% depth 30% 4060 (41°F)

retention
25°C (41°F)
(41°F)

retention
retention
Discharge Discharge Discharge 6040
60 40°C
(104°F) 30°C
(86°F)
Discharge
Discharge Discharge
Discharge Discharge
Discharge (77°F)

CapacityCapacity
20 Ambient temperature
40 depth 100% depth 50% depth 30% (104°F) (86°F) (77°F)

Capacity
40 40
20 depth 100%
depth Ambient
100%
25°C depth temperature
depth
(77°F) 50%
50% depth 30%
depth 30%
(69.2) 2040 40°C
40°C
40°C 30°C
30°C
30°C 25°C
25°C
25°C
25°C (77°F) 4020
40

(0.3)
0.01
2.72 0 (104°F) (86°F) (77°F)
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)

Capacity
2020 Ambient temperature

Capacity
20 0 Ambient
Ambient temperature
temperature
Contents indicated (including the recycle marking, etc.) 0 40025°C (77°F) 800 1,200 020
0 25°C
400 (77°F)
25°C (77°F) 800 1,200 20 20
are subject to change without notice. Battery case resin: standard (UL94 HB) 00 0 Number of cycles (times) 00 2 4 6 8 10 12 14 16 18 20
Number of cycles (times) 0 2 4 Storage
6 8 period
1 0 (mth.)
12 14 16 18 20
00 0 400
400
400 800
800
800 1,200
1,200
1,200 00 0 Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Number
Number
Numberofofof
cycles
cycles (times)
(times)
cycles (times) 00 0 22 2 44 4 66 6 88 8 11010 0 11212 2 11414 4 11616 6 11818 8 22020 0
Storage
Storage period
period
Storage period (mth.)
(mth.)
(mth.)
Name LC-R124R5P*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30 160 16.0 120 DISCHARGE CURRENT
Nominal voltage 12V CHARGE CHARACTERISTICS FOR
BatteryCYCLE
voltage USE AND BY
20 160 16.0 120
Nominal capacity (20 hour rate) 4.5Ah 140 Battery voltage 14.0 0.05CA
15 100
140
160 14.0
16.0 120 0.10CA
0.05CA
Length 70mm 0.8 160
120160 16.0
12.016.0 120
120
100 0.10CA
10 Battery voltage

(%)
Battery
Battery voltage
voltage
0.8

(CA)
120 Charge quantity (to discharge quantity) 12.0 0.25CA

(V)
(%) (%)
Dimensions Width 97mm 140
140
140 14.0
14.0 80 0.05CA
10.014.0 0.05CA
0.05CA

(CA) (CA)
Charge quantity (to discharge quantity) 0.50CA
0.25CA
(h)

100 100

(%)
(V) (V)
quantity
Ś Discharge 100
100
80 0.10CA
0.10CA
0.10CA
0.60.8

voltage
100 10.0 0.50CA

(%) (%)
Height 108mm 5

quantity
current
0.80.8 120 —
— Ś Discharge
100% (0.05CA*20H) 12.0
120
80120 12.0
12.0

(%)
0.6

voltage

CapacityCapacity
(%)
8.0 60

(CA)
current
40°C Charge —quantity
100% (to(to discharge
(0.05CA*20H) quantity) 1.00CA
0.25CA

(CA)

Duration of discharge

Charge
— quantity
Charge—50%
quantity discharge
(0.05CA*10H)
(to dischargequantity)
quantity) 0.25CA
0.25CA

(V)
80

Capacity
(V)
Approx. mass 5.0kg 80 8.0 80 80
60 1.00CA
0.50CA
100 — 10.0 2.00CA

(%)
3 50% (0.05CA*10H) 0.50CA
0.50CA

quantity
100 — Discharge 10.0

(%)
100 śŚŚ Charge
6.0 10.0

quantity
quantity
0.4
0.6 60 ŚDischarge
Discharge

voltage
0.60.6 2.00CA

voltage
voltage
Terminal

Charge
Faston 187 3.00CA

current

Battery
Charge
——100%
— 100% (0.05CA*20H)
ś
0.4

current
current
2 60 ȼ— —Charge
— voltage:
100% (0.05CA*20H)14.7V (2.45V/cell)
(0.05CA*20H) 6.0 40

Charge

Capacity
25°C 80 8.0

Capacity
60

Charge
3.00CA

Battery
8080 14.7V (2.45V/cell) 8.0 1.00CA
4.0 8.0 60 60
—ȼ—
—— Charge
50% voltage:
(0.05CA*10H) 40 1.00CA
1.00CA
—Charge
—50% current:
(0.05CA*10H)
50% 0.40CA
(0.05CA*10H)

Charge
20 hour rate 4.5Ah 1.5 40
0.2
0.4 40 Ŝśś Charge
Chargecurrent:
Charge
Temperature:
Charge 0.40CA
25°C (77°F) 4.0 2.00CA
2.00CA
2.00CA
0.40.4
0.2 60
6060
ś 6.0
6.06.0 20

Charge
10 hour rate 3.00CA

Battery
4.1Ah 20 (2.45V/cell) 2.0

Charge
1 3.00CA

Charge
3.00CA

Battery
Battery
Capacity ȼȼŜȼ Temperature:
Charge
Charge
Charge voltage:
voltage: 25°C
14.7V
14.7V
voltage: (77°F)
14.7V (2.45V/cell)
(2.45V/cell) 40
40 40

Charge
0°C 20

Charge
Charge
(25°C) 3 hour rate 3.6Ah 50 20
40 Charge
Charge
Charge
Charge current
current:
current: 0.40CA
0.40CA
current: 0.40CA 2.0
4.0
00.2 40
0 40 4.0
0.0 4.0
40 0.2 Charge current 0
00.2 ŜŜŜ Temperature:
Temperature:
Temperature: 25°C
25°C (77°F)
(77°F)
25°C (77°F)
1 hour rate 3.1Ah 30 -15°C 0 0.0 2020
20 0
20
20200 2 4 6 8 10 12 2.0
2.02.0 -15 0 15 30 45
0 2 Charge4 Charge
Charge 6 current
Charge
time 8
current
current
(h) 10 12 -15 0
Battery 15
temperature 30
(°C) 45
(min.)

Fully charged battery 20 000 000 0.0


Impedance 40mΩ Charge time (h) 0.00.0 00 0 Battery temperature (°C)
(25°C)
000 222 444 666 888 10 1010 12 1212 -15
-15-15 00 0 151515 3030
30 4545
45
40°C 102% 10 Charge
Charge
Charge time
timetime (h)
(h) (h) Battery
Battery temperature
temperature
Battery (°C)
(°C)
temperature (°C)
Temperature dependency 25°C 100%
of capacity (20 hour rate) 0°C 85%
5

-15°C 65% 3 DISCHARGE


15 CHARACTERISTICS
100 200 300 500 1 2 3 5 7 10 20 15
After 3 month 91% 14
(mA) (A) 14
Self-discharge
After 6 month 83% 1315
1515
(25°C) Discharge current 13
1214

voltage (V)
After 12 month 64% 1414
12

(V) (V)
1113
1313

voltage
11
12

(V)
10
1212

voltage (V)
WATT TABLE (25°C) (Wattage/battery) 1.125A 0.45A 0.225A
10 2.25A 0.45A

voltage
4.5A 0.225A
911

Terminal
voltage
1111 13.5A 2.25A 1.125A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 4.5A

Terminal
9 13.5A
9.6V 270 214 139.4 106.4 89.2 66.6 47 37.6 25.8 19.98 14.88 11.42 9.44 7.58 5.02 2.72
810
1010 1.125A 0.45A
0.45A
0.45A 0.225A
0.225A
0.225A
8 2.25A
2.25A
2.25A 1.125A
1.125A
4.5A

Terminal
7999 4.5A
4.5A

Terminal
Terminal
13.5A
13.5A
13.5A
9.9V 250 200 136.6 105.6 87.8 65.8 46.6 37.6 25.4 19.84 14.8 11.36 9.36 7.56 5 2.72 7
10.2V 232 188 133 103.6 86.2 65 46.2 36.8 24.8 19.32 14.66 11.28 9.28 7.5 4.96 2.7
6888
6
10.5V 206 168 123.2 96.4 82 63.6 45.4 36 24.2 18.64 14.42 11.2 9.2 7.4 4.92 2.7 5777
05 1 2 5 10 20 40 60 2 4 6 8 10 20 40
10.8V 174 148 110 89.8 79.8 61.4 44.8 35.4 23.6 17.76 14.14 11.06 8.98 7.28 4.88 2.68 6660 1 2 5 10 20 40 60 2 4 6 (h)8 10 20 40
(min.)
555 (min.) (h)
(Ampere/battery)
000 111 222 555 10
1010 20
20 4040
20 Duration 60
60
40of discharge
60 222 444 666 88810 10
10 20
2020 40
4040
AMPERE TABLE (25°C) (min.) Duration of discharge (h)
(min.)
(min.) (h)(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Duration
Duration ofofof
Duration discharge
discharge
discharge
9.6V 24.3 19.13 12.44 9.25 7.69 5.69 4.00 3.19 2.19 1.69 1.25 0.956 0.788 0.633 0.419 0.227
9.9V 22.6 17.94 12.19 9.19 7.56 5.63 3.98 3.19 2.14 1.68 1.24 0.950 0.781 0.630 0.417 0.226
10.2V 20.8 16.81 11.88 9.00 7.44 5.56 3.94 3.13 2.10 1.63 1.23 0.944 0.775 0.625 0.413 0.226
10.5V 18.5 15.06 11.00 8.38 7.06 5.44 3.88 3.06 2.06 1.58 1.21 0.938 0.769 0.618 0.411 0.225
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 15.6 13.31 9.81 7.81 6.88 5.25 3.81 3.00 2.00 1.50 1.19 0.925 0.750 0.608 0.406 0.224 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

54 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V124R5P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V124R5P. 55
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-R127R2P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-R127R2P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT. G193046
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
4.75 6.35 Terminal type 0.360A - 1.44A - 3.60A - 7.20A - 14.4A -
DIMENSIONS (MM) Control voltage: 14.5V - 14.9V Discharge current
(option) Cycle use 1.44A 3.60A 7.20A 14.4A 21.6A

6.35

4.5
Initial current: 2.88A or smaller

3.2
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

(187)
(250)
CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
+1.5 +1.5
151 -0.5 64.5-0.5
120 120

(6)
(65.15) (48)
120
120 120
120
120
100 120
100

(%) (%)
100
100 100
100

(%)
ratio
100 100

(%)
80 80

(%) (%)

ratio
ratio
+1.5
94 -0.5
5°C

ratio
80
80 80
80

retention
80 80

(%)
Capacity
60 60 (41°F)

(%)
5°C
5°C

retention
5°C

retention
retention
Discharge Discharge Discharge

Capacity
60

Capacity
60 60
60 (41°F)
(41°F)

Capacity
60
40 60 40°C 30°C 25°C (41°F)
depth 100%
Discharge
Discharge depth 50%
Discharge
Discharge depth 30%
Discharge
Discharge 40
Discharge Discharge Discharge

Capacity
40
40 depth
depth 100%
100% depth
depth 50%
50% depth
depth 30%
30% 40
40 (104°F)
40°C
40°C (86°F)
30°C
30°C (77°F)
25°C
25°C
40 depth 100% depth 50% depth 30% 40 40°C 30°C 25°C
Ambient temperature

Capacity
20

Capacity
(150.2) (63.7) 20 (104°F)
(104°F) (86°F)
(86°F) (77°F)

Capacity
(104°F) (86°F) (77°F)
(77°F)
20
20 25°C (77°F)
Ambient
Ambient temperature
temperature 20

(0.3)
20 Ambient temperature 20
20
0 25°C
25°C (77°F)
(77°F) 0
Contents indicated (including the recycle marking, etc.) 25°C (77°F)
00 0 400 800 1,200 00 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: standard (UL94 HB) 0 0
00 Number
400 of cycles (times)
400 800
800 1,200
1,200 00 22 44 Storage
66 88 period
10 (mth.)
10 12
12 1414 16
16 18
18 20
20
0 400 800 1,200 0 2 4 6 8 10 12 14 16 18 20
Number
Number of
of cycles
cycles (times)
(times) Storage
Storage period
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Number of cycles (times) Storage period (mth.)

Name LC-R127R2PG/PG1*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE


30
Nominal voltage 12V
20
CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
160 16.0 120
Nominal capacity (20 hour rate) 7.2Ah Battery voltage
40°C 160
160
140
160 16.0
16.0
14.0
16.0 120
120
Length 151mm 10 Battery
Batteryvoltage
Battery voltage
voltage 120 0.05CA
100 0.10CA
0.8 140
140
120
140 14.0
14.0
12.0
14.0 0.05CA
0.05CA

(%)(%)
Dimensions Width 64.5mm 100
100 0.05CA

(CA)(CA)
Charge quantity (to discharge quantity) 0.10CA
0.10CA
5 100

(V) (V)
0.8 0.25CA
(h)

0.8
0.8 120
120 12.0
12.0 80 0.10CA

(%)
Height 100mm 100
120 10.0
12.0

quantity
Discharge 0.50CA

(%) (%)
(%)
Charge
Ś quantity (to
(todischarge
dischargequantity)

(CA)
0.6 Charge quantity quantity)

voltage
25°C 0.25CA

(CA)

(V)
Charge
—quantity (to discharge quantity) 0.25CA
3

current
80

(V)
— 100% (0.05CA*20H) 80 0.25CA
Approx. mass 100
100 10.0
10.0

quantity
2.50kg 0.50CA
Duration of discharge

80

quantity
80 Ś Discharge
Discharge 8.0 0.50CA

(%)
100 10.0

Capacity
Ś

quantity
0.6

voltage
0.6 — 50% (0.05CA*10H) 0.50CA

voltage
Discharge 60

(%)
Ś

current
0.6 1.00CA

voltage

current
—— 100%
— 100%(0.05CA*20H)
(0.05CA*20H)

current
Terminal Faston 187/250 — 100% (0.05CA*20H)
80
80 — Charge 8.0
8.0

Capacity
ś—
0.4

Capacity
60
80 —— 50%
— 50%(0.05CA*10H)
(0.05CA*10H) 6.0
8.0 60
60 2.00CA

Capacity
1.00CA

Charge
ȼ— 50% (0.05CA*10H) 1.00CA

Battery
—Charge voltage: 14.7V (2.45V/cell) 60 1.00CA
3.00CA

Charge
20 hour rate 7.2Ah 0.4
0.4 ś Charge
ś Charge 40 2.00CA
60 0.4 60
60
40
Charge
ś Charge current: 0.40CA 6.0
6.0
4.0 2.00CA
2.00CA

Charge
60 6.0

Battery
Charge

Battery
0°C ȼ Charge
ȼ Chargevoltage:
voltage:14.7V
14.7V(2.45V/cell)
(2.45V/cell)

Charge

Battery
3.00CA

Charge
40 3.00CA

Charge
Capacity 10 hour rate 6.6Ah 0.2 Charge
ȼ Temperature:voltage: 14.7V
25°C (2.45V/cell)
(77°F) 40 3.00CA

Charge
40
Ŝ
Charge
Chargecurrent:
current:0.40CA
0.40CA 4.0 40
(25°C) 40
20
40 Charge current: 0.40CA 4.0
2.0
4.0 20
3 hour rate 5.8Ah 30 0.2
0.2 Ŝ Temperature:
Ŝ Temperature: 25°C (77°F)
25°C (77°F)
(77°F)
0.2 Ŝ Temperature: 25°C
Charge current 20
20
1 hour rate 4.9Ah 0 20
20
0
20 2.0
2.0
0.0
2.0 20
Charge
Chargecurrent
current 0
000 000 0 2 4 Charge
6 current
8 10 12 0.0
Fully charged battery 0.0
0.0 00-15 0 15 30 45
(min.)

Impedance 21mΩ 10 -15°C 0


(25°C) 000 222 444Charge
666time 88(h)
8 10
10 12
12 Battery15
temperature
10 12 -15
-15
-15
00
0 15
15 30 (°C)
30
30
45
45
45
Charge
Chargetime
Charge time(h)
time (h)
(h) Battery temperature (°C)
40°C 102% Battery temperature (°C)
Battery temperature (°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
20.0
After 3 month 91% 1 20.0
20.0
Self-discharge 0.1 0.3 1 3 10 30 100 20.0
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 15.0

(V) (V)
15.0
15.0
15.0

voltage
(V)
(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
voltage
voltage
10.0 0.360A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 1.80A

Terminal
10.0
10.0 7.20A 0.360A
9.6V 430 335 220 167 134 98.4 72.1 56.5 44.6 34.7 24.7 19.2 15.4 12.8 8.39 4.60 10.0 21.6A 1.80A
1.80A 0.360A
0.360A
1.80A

Terminal
7.20A

Terminal
7.20A

Terminal
9.9V 405 287 187 159 130 96.4 71.6 55.1 43.7 34.4 24.5 19.1 15.3 12.5 8.35 4.59 21.6A
21.6A 7.20A
21.6A
5.0
10.2V 379 273 182 151 126 94.3 68.6 53.6 41.4 32.5 23.5 18.7 14.6 12.2 8.00 4.43
5.0
5.0
10.5V 343 248 174 144 120 90.8 66.8 52.4 39.8 31.5 23.0 18.3 14.5 12.1 7.96 4.42 5.0

10.8V 308 223 164 138 115 87.2 62.6 48.4 37.2 28.1 21.4 16.9 13.3 11.2 7.41 4.13
0.0
0.0 0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
0.0
0.0
AMPERE TABLE (25°C) (Ampere/battery) 00 11 22 44 66(min.)
88 10
10 20
20 40
40 60
60 22 44 66 (h)
88 10
10 20
20 40
40
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(min.)
(min.) (h)
(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.) Duration of discharge (h)

9.6V 38.9 30.6 19.9 14.8 12.3 9.10 6.40 5.10 3.50 2.70 2.00 1.53 1.26 1.02 0.670 0.363 Duration
Duration of
of discharge
discharge
Duration of discharge
9.9V 36.1 28.7 19.5 14.7 12.1 9.00 6.36 5.05 3.43 2.68 1.99 1.52 1.25 1.01 0.667 0.362
10.2V 34.2 26.9 19.0 14.4 11.9 8.90 6.30 5.00 3.36 2.61 1.97 1.51 1.24 1.00 0.660 0.361
10.5V 31.4 24.1 17.6 13.4 11.3 8.70 6.20 4.90 3.29 2.52 1.94 1.50 1.23 0.988 0.657 0.360
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 29.0 22.3 15.7 12.5 11.0 8.40 6.10 4.80 3.20 2.40 1.90 1.48 1.20 0.972 0.650 0.358 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

56 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V127R2PG/PG1. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-V127R2PG/PG1. 57
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-RA1212P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-RA1212P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT. G100001
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
4.75 6.35 0.600A - 2.40A - 6.00A - 12.0A - 24.0A -
DIMENSIONS (MM) Control voltage: 14.5V - 14.9V Discharge current
Cycle use 2.40A 6.00A 12.0A 24.0A 36.0A

6.35

4.5
Initial current: 4.80A or smaller

3.2
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

(187)
(250)
Terminal type CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
(option)
+1.5 +1.5 120 120
98 -0.5 151 -0.5
120
120
120 120
120
120
100 100

(%) (%)
13.5±0.75
100
100
100 100
100
100

ratioratio
(%)
ratio (%)
80 80

(%) (%)
5°C

retention ratio
80 80

retention
80
80 80
80

Capacity
60

(%)
(41°F)

Capacity (%)
60 5°C5°C
5°C

(6)

retention
Capacity retention
Discharge Discharge Discharge

Capacity
60 60 (41°F)

Capacity
60
60 60
60 (41°F)
(41°F)

+1.5
40°C 30°C

94 -0.5
40 depth 100% depth 50% depth 30% 40 25°C
Discharge
Discharge
Discharge Discharge
Discharge
Discharge Discharge
Discharge
Discharge

Capacity
40 (104°F)
40°C
40°C
40°C (86°F)
30°C
30°C
30°C (77°F)
25°C
25°C
40
40 depth
depth100%
depth 100% depth
100% depth50%
depth 50%
50% depth
depth30%
depth 30%
30% 40
40
40 25°C
20 Ambient temperature

Capacity
20

Capacity
(104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
(77°F)
20
20
20 25°C (77°F)
Ambient temperature
Ambient temperature
Ambient temperature 20
20
20
0 25°C 0
Contents indicated (including the recycle marking, etc.) 25°C(77°F)
25°C (77°F)
(77°F)
000 0 400 800 1,200 000 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: standard (UL94 HB)
000 Number
400 of cycles (times)
400
400 800800
800 1,200
1,200
1,200 000 222 444 6Storage period12
66 888 10 10 12
10
(mth.)
12 1414 16
14 16 18
16 18 20
18 20
20
Number
Numberofof
Number ofcycles
cycles(times)
cycles (times)
(times) Storage
Storageperiod
Storage period(mth.)
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-RA1212PG/PG1*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
160 16.0 120
Nominal capacity (20 hour rate) 12Ah 40°C Battery voltage
160
160
160
140 16.0
16.0
16.0
14.0 120
120
120
Length 151mm 10 Battery
Battery
Batteryvoltage
voltage
voltage 0.05CA
100 0.10CA
Dimensions Width
0.8 140
140
140
120 14.0
14.0
14.0
12.0 0.05CA
0.05CA
98mm 100
100 0.05CA
Charge quantity (to discharge quantity) 100 0.10CA

(%) (%)
5 0.10CA
0.10CA
(h)

0.8 0.25CA

(CA)(CA)
0.8
0.8 120 12.0 80

(V) (V)
Height 100mm 120
120
100 12.0
12.0
10.0 0.50CA

(%) (%)
Charge Discharge
Śquantity (to(todischarge quantity)
0.6

quantity
25°C Charge
Charge quantity
quantity (to discharge
discharge quantity)
quantity)

(%)
quantity (%)
3 0.25CA
0.25CA
0.25CA

voltage
(CA)
current (CA)
— 100% (0.05CA*20H) 80
— 80
80

current

(V)
Approx. mass
Duration of discharge

3.85kg

voltage (V)
100
100
100
80 10.0
10.0
10.0
8.0 0.50CA
0.50CA
0.50CA

Capacity
ŚŚ Discharge

(%)
Capacity (%)
0.6 Ś Discharge
— Discharge 60

quantity
0.6
0.6 50% (0.05CA*10H) 1.00CA

Charge quantity

voltage
———100% (0.05CA*20H)

Battery voltage
— 100% (0.05CA*20H)

current
Terminal Faston 187/250 ś—— 100% (0.05CA*20H)

Charge current
0.4 80 Charge 8.0 2.00CA

Capacity
80
80 8.0
8.0

Capacity
60 ——
— —50%
— (0.05CA*10H)
50%
50% (0.05CA*10H)
(0.05CA*10H) 6.0 60
60
60 1.00CA
1.00CA
1.00CA
ȼ—

Charge

Battery
20 hour rate 12Ah Charge voltage: 14.7V (2.45V/cell) 40 3.00CA

Charge
60 0.4
0.4
0.4 60
śśśCharge
Charge
Charge 6.0 2.00CA
2.00CA
2.00CA
0°C 60
60
40 Charge current: 0.40CA 6.0
6.0
4.0

Charge

Battery
3.00CA

Charge
ȼȼȼCharge voltage: 14.7V (2.45V/cell) 3.00CA

Battery
10 hour rate 11Ah 0.2 Charge
Charge voltage:
voltage: 14.7V
14.7V (2.45V/cell)
(2.45V/cell) 40 3.00CA

Charge
Capacity 40
40

Charge
Ŝ Temperature: 25°C (77°F)
40 Charge
Charge
Charge current: 0.40CA
current:
current: 0.40CA
0.40CA 4.0 20
(25°C) 3 hour rate 9.3Ah 30 0.2 40
40
20 4.0
4.0
2.0
0.2
0.2 ŜŜŜTemperature:
Temperature:
Temperature: 25°C
Charge current 25°C
25°C (77°F)
(77°F)
(77°F)
0 20
20 2.0
2.0 20
20
20
1 hour rate 8.5Ah 20
0 2.0
0.0 0
Charge
Chargecurrent
Charge current
current
000 000 0 2 4 6 8 10 12 0.0
0.0
0.0
Fully charged battery -15°C 000-15 0 15 30 45
(min.)

Impedance 15mΩ 10
(25°C) 000 222 4Charge
44 666time88(h)
8 10 10
10 12
12
12 -15-15 000 Battery 15
temperature
15 30(°C)
30 45
45
-15 15 30 45
40°C 102% Charge
Chargetime
Charge time(h)
time (h)
(h) Battery temperature
Battery temperature(°C)
temperature (°C)
(°C)
5 Battery
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
20.0
20.0
Self-discharge 0.1 0.3 1 3 10 30 100
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 15.0
15.0
15.0
15.0

(V) (V)
voltage
WATT TABLE (25°C) (Wattage/battery)

(V)
10.0 0.600A

voltage
3.00A

voltage
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 12.0A
10.0
10.0
10.0 36.0A 0.600A
0.600A
0.600A
3.00A
3.00A
3.00A

Terminal
9.6V 679 559 384 298 247 183 137 105 70.3 54.5 38.1 28.8 24.1 21.7 13.3 7.22
12.0A
12.0A
12.0A
36.0A
36.0A
36.0A
Terminal
Terminal
9.9V 649 537 373 288 241 177 135 104 69.9 54.2 37.8 28.7 24.0 21.7 13.3 7.22
5.0
10.2V 607 506 363 282 235 175 134 102 69.1 53.9 37.5 28.6 23.9 21.6 13.2 7.21
5.0
5.0
5.0
10.5V 556 475 343 271 231 172 133 100 68.5 53.3 36.9 28.5 23.8 21.6 13.2 7.20
10.8V 495 434 321 261 225 166 123 97.8 66.1 52.1 36.3 28.4 23.7 21.5 13.1 7.18 0.0
0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.0
0.0
AMPERE TABLE (25°C) (Ampere/battery) 000 111 222 333 555 (min.)
777 10 10
10 20
20
20 40
40
40 60
60
60 222 444 666 (h)
888 10
10
10 20
20
20 40
40
40
(min.)
(min.)
(min.) (h)
(h)
(h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h Duration of discharge
9.6V 61.1 50.1 34.3 25.9 21.3 15.6 11.7 8.90 5.95 4.60 3.20 2.41 2.01 1.81 1.11 0.602 Duration
Durationofof
Duration ofdischarge
discharge
discharge
9.9V 58.4 48.2 33.3 25.0 20.8 15.1 11.5 8.80 5.92 4.58 3.18 2.40 2.01 1.81 1.11 0.602
10.2V 54.6 45.4 32.4 24.5 20.3 14.9 11.4 8.70 5.85 4.55 3.15 2.39 2.00 1.80 1.10 0.601
10.5V 50.0 42.6 30.6 23.6 19.9 14.7 11.3 8.50 5.80 4.50 3.10 2.38 2.00 1.80 1.10 0.600
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 44.5 38.9 28.7 22.7 19.4 14.2 10.5 8.30 5.60 4.40 3.05 2.37 1.99 1.79 1.09 0.598 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

58 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-VA1212PG/PG1. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-VA1212PG/PG1. 59
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-RA1215P*1 FOR MAIN AND STANDBY POWER SUPPLIES. LC-RA1215P*1


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.75A - 3A - 7.5A - 15A - 30A -
DIMENSIONS (MM) 4.75 6.35 Control voltage: 14.5V - 14.9V Discharge current
Cycle use 3A 7.5A 15A 30A 45A
Initial current: 6A or smaller

6.35

4.5
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

3.2
(187)
(250) CYCLE LIFE VS. DEPTH OF DISCHARGE (ACC. IEC 61056) RESIDUAL CAPACITY TEST RESULT
Terminal type
(option) 120
120 120
120
+1.5 +1.5 120 120
98 -0.5 151 -0.5 120120 120120

Capacity Retention Ratio (%)


(%)
100
100 100
100

(%)(%)
13.5±0.75 100 100

Ratio
100

Capacity Retention Ratio (%)


100 100100

Ratio
8080 8080

(%)
(%) (%)

Ratio
80 80 5°C
5°C

(6)

Retention
(%)(%)
80 80 80 80 5°C

Capacity
6060

Capacity

Retention
6060 (41°F)
(41°F)
5°C 5°C

Retention
Capacity
60 Discharge
Discharge Discharge
Discharge Discharge
Discharge 60 (41°F)

Capacity
60 60 (41°F)

Capacity
60
4040 Discharge Discharge Discharge 60 40°C
40°C 30°C
30°C 25°C (41°F)
25°C

+1.5
94 -0.5
depth 100%
depth 100% depth depth 50%
50% depth 30%
depth 30% 4040
Discharge
Discharge Discharge Discharge
depth 100% Discharge Discharge 40°C (86°F) 30°C 25°C

Capacity
40 depth 50% depth 30% 40 (104°F)
(104°F) (86°F) (77°F)
(77°F)
40 40°C
40°C 30°C 25°C
40 depth 100% depth 50% depth 30% 40 (104°F)30°C (86°F) 25°C (77°F)

Capacity
2020 depth 100% depth
Ambient
Ambient 50%
temperaturedepth 30%
temperature 40
2020

Capacity
(104°F) (86°F)
(104°F) (86°F) (77°F)
(77°F)
20 Ambient
25°C (77°F)
25°C temperature
(77°F) 20
200200 Ambient
Ambient temperature
temperature 200200
25°C (77°F)
Contents indicated (including the recycle marking, etc.) 25°C
25°C (77°F)
(77°F)
0 0 0 400
400 800800 1200
1200 0 0 0 2 2 4 4 6 6 8 8 1010 1212 1414 1616 1818 2020
are subject to change without notice. Battery case resin: standard (UL94 HB) 0 0 0 0
0 400
Number
Number of of
cycles
cycles 800
(times)
(times) 1200 0 2 4Storage
6 period
Storage (mth.)
8period
10 (mth.)
12 14 16 18 20
0 0 400400 800800 1200
1200 0 0 2 2 4 4 6 6 8 8 10 1012 1214 1416 1618 1820 20
Number ofofcycles (times) Storage
Storage period
period (mth.)
(mth.)
Number
Number cycles
of cycles (times)
(times) Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-RA1215P/P1*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V 20 CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
16.0
16.0 120
120
Nominal capacity (20 hour rate) 15Ah 160
160 Battery voltage
Battery voltage
40°C
16.0
14.0
16.0
14.0
16.0 120
120 0.05CA
Length 151mm 10 160
140
160160
140 Battery voltage 120
100
0.05CA
Charge
Charge Battery
quantity
Battery (to
quantity voltage
discharge
voltage
(to quantity)
discharge quantity) 100 0.10CA
0.10CA
Dimensions Width 98mm 140
120
14.0
14.0
12.0
12.0
14.0 0.05CA
0.05CA
0.80.8 140140
120 100
100 0.05CA

(%) (%)
(%) (%)
5 Charge quantity (to
(todischarge quantity) 100 0.25CA0.10CA
0.25CA
0.10CA

(CA) (CA)
Charge quantity discharge quantity)

(CA)(CA)
25°C Charge quantity (to discharge quantity) 8080 0.10CA

Battery voltage (V)


(V) (V)
(h)

Height 100mm 12.0


10.0
12.0
10.0
12.0 0.50CA
0.50CA

Capacity (%)
100
120

(%) (%)
0.80.8 120120
100

quantity
quantity
0.8 Ś Discharge
Ś Discharge
0.25CA
0.25CA

Charge quantity (%)


3

voltage
0.60.6 0.25CA

current
䚷䚷䚷䚷

(CA)
current
Approx. mass 4.15kg 80
80

(V)
䚷 䚷100% 100%(0.05CA*20H)
(0.05CA*20H) 80

Battery voltage (V)


8.010.0
10.0
8.0 0.50CA

Capacity
0.50CA
Duration of discharge

80 10.0

(%)
100
10080 6060 0.50CA
1.00CA

Capacity (%)
100 䚷䚷 1.00CA

quantity
quantity
ŚŚ䚷䚷 Discharge
Discharge
50% (0.05CA*10H)
䚷䚷 50% (0.05CA*10H)
Ś Discharge

voltage
voltage
Terminal Faston 187/250 0.60.6

current
2.00CA

current
0.6 䚷䚷 2.00CA

Charge current
䚷䚷 100%
100% (0.05CA*20H)
(0.05CA*20H) 6.08.0

Capacity

100% (0.05CA*20H) 6.0
8.0

Capacity

䚷 Charge
0.40.4 8060
8080
60 ś ś Charge 8.0 60 60
60 1.00CA
1.00CA

Charge
䚷䚷

Charge
䚷䚷䚷 1.00CA
3.00CA

Battery
20 hour rate 15Ah
䚷䚷
50%䚷 50%
50%
Charge (0.05CA*10H)
(0.05CA*10H)
(0.05CA*10H)
voltage: 14.7V (2.45V/cell) 4040 3.00CA

Charge
Charge voltage: 14.7V (2.45V/cell)

Charge
60 䚷ś 䚷Charge 4.06.0 2.00CA
2.00CA 2.00CA
0.4 40
0.40.4 606060
40 śCharge
Charge
Charge
ś Charge current: 0.40CA
current: 0.40CA 6.0 6.0
4.0

Charge

Battery
3.00CA

Charge
10 hour rate 13Ah 䚷

Battery
Capacity 0°C 0.20.2 䚷 䚷 䚷 䚷Charge voltage: 14.7V (2.45V/cell) 40 3.00CA3.00CA

Charge
Temperature:
ŜChargeTemperature:
ŜCharge 25°C
voltage:
voltage: 14.7V (77°F)
25°C
14.7V (77°F)
(2.45V/cell)
(2.45V/cell) 40 40

Charge
20 䚷䚷Charge
䚷 Charge 2.04.0
2.0 2020
(25°C) 3 hour rate 12Ah 30 404040
20 Charge current:
current: 0.40CA
0.40CA
current: 0.40CA
Charge current
4.0 4.0
0.2
0.20.2 Ŝ䚷䚷 Temperature:
Ŝ䚷 Temperature: 25°C
Ŝ Temperature: 25°C (77°F)
Charge
25°C current
(77°F)
(77°F)
1 hour rate 10Ah 0 0 0200
2020 0.02.0
2.0 0.0
2.0 20020
20
Charge
Charge current
current
0
-15°C Charge current
0 2 2 4 4 6 6 8 8 1010
Fully charged battery 00 0 00 0 0 0.0 0.0 -15-15 0 0 1515 3030 4545
(min.)

Impedance 15mΩ 10 Charge time (h)(h) 0.0 0 00


(25°C) Charge time Battery temperature
Battery (°C)
temperature (°C)
000 2 22 4 44 6 66 8 88 10
10 10 -15
-15 -15 0 0 15
15 15 30 30 45 45 45
30
Charge time (h) 0
40°C 102% Charge time
Charge (h)(h)
time Battery
Battery temperature
temperature (°C)(°C)
5 Battery temperature (°C)
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
1515 CHARACTERISTICS
After 3 month 91% 1 1415
15 14
Self-discharge 0.3 1 3 10 30 100
15
After 6 month 82% 1314
14 13

(V)(V) (V)
(V) (V)
(25°C) Discharge current (A) 14
After 12 month 64% 12 12
13 13

voltage
voltage
13
11 11
12 12

voltage
voltage
12
10 0.75A
0.75A

voltage
WATT TABLE (25°C) (Wattage/battery) 11 10
11 3.75A 1.5A
1.5A

Terminal
3.75A

Terminal
11
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 10 9109 AA
1515 7.5A
7.5A
3.75A 1.5A
1.5A
0.75A
0.75A

Terminal
3.75A

Terminal
108 8 45A
45A 1.5A 0.75A
9 9 7.5A 3.75A

Terminal
9.6V 850 682 455 350 292 217 157 123 83.9 65.0 47.1 36.0 29.9 25.2 16.2 8.75 15 A 7.5A
15 A
9 15 A 7.5A
9.9V 799 646 444 343 286 213 156 122 82.8 64.6 46.9 35.8 29.7 25.1 16.1 8.74 87 87 45A45A
8 45A
10.2V 741 607 433 336 281 211 154 121 81.4 63.4 46.4 35.7 29.5 24.9 15.9 8.72 76 76
7
5
10.5V 667 555 404 318 270 206 152 118 80.1 61.9 45.7 35.5 29.4 24.8 15.8 8.70 6 65
10.8V 576 497 368 300 263 199 146 116 77.7 59.6 44.8 35.1 28.9 24.5 15.7 8.66 6 0 0
5 5
1 1 2 2 4 4 6 6 8 81010 2020 4040 6060 2 2 4 4 6 6 8 8 1010 2020 4040
(min.)
(min.) (h)(h)
50 0 1 1 2 2 4 4 6 68 810 10 20 20 40 40 60 60 2 2 4 4 6 6 8 8 10 10 20 20 40 40
(Ampere/battery) 0 1 2 4 (min.)
6 8 10
(min.) 20 Duration
40 of of
Duration 60discharge 2
discharge 4 6(h) (h)8 10 20 40
AMPERE TABLE (25°C)
(min.) (h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h Duration
Duration of discharge
of discharge
9.6V 76.5 61.2 40.6 30.4 25.2 18.5 13.4 10.50 7.11 5.49 3.96 3.01 2.49 2.10 1.35 0.755 Duration of discharge
9.9V 71.8 58.0 39.7 29.9 24.7 18.2 13.3 10.40 7.01 5.45 3.94 3.00 2.48 2.09 1.34 0.753
10.2V 66.6 54.5 38.6 29.2 24.2 18.1 13.1 10.30 6.89 5.36 3.90 2.99 2.46 2.08 1.33 0.752
10.5V 59.9 49.8 36.1 27.6 23.3 17.6 13.0 10.00 6.78 5.22 3.84 2.97 2.45 2.07 1.32 0.750
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 51.8 44.6 32.9 26.1 22.7 17.0 12.5 9.82 6.58 5.03 3.77 2.94 2.41 2.04 1.31 0.747 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

60 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-VA1215P/P1. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-VA1215P/P1. 61
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-V1233P FOR MAIN AND STANDBY POWER SUPPLIES. LC-V1233P


EXPECTED TRICKLE DESIGN LIFE: 6 – 9 YEARS AT 20°C
ACCORDING TO EUROBAT.
Terminal type CHARGING METHOD (25°C) CUT-OFF VOLTAGE

DIMENSIONS (MM) 16 M6 1.65A - 6.60A - 16.5A - 33.0A - 66.0A -


Control voltage: 13.6V - 13.8V Discharge current
Trickle use 6.60A 16.5A 33.0A 66.0A 99.0A
Initial current: 4.95A or smaller

16
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

(L)
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE RESIDUAL CAPACITY TEST RESULT
195.6±2 130±2
159 100 120
50 100 120

(16)
7.5
16 6 26.5 100
100
100 120
120
120
Charging voltage 100

(%)
Charging voltage 100

(%)(%)
2.275V/cell
Charging
Charging
Chargingvoltage
2.275V/cellvoltage

4.5
voltage 100
100

(years)

ratio
100

(%)
ratio (%)
10

life(years)

ratio
10 2.275V/cell
2.275V/cell 80
2.275V/cell 80

9
5°C

(years)
(years)

ratio
life (years)

retention ratio
10
10 5°C

retention
10 80
80
80

retention
60 (41°F)
5°C
5°C
(41°F)
5°C

155±2
60

lifelife

retention
180

Capacity retention
Service
60
60 (41°F)
(41°F)
60 25°C (41°F)

Service life
1 40°C 30°C

Service
1 40 40°C 30°C 25°C
40

Capacity
Service
(104°F) (86°F)

Service
111 (77°F)

Capacity
40
40
40 40°C
40°C
(104°F)
40°C 30°C
30°C
(86°F)
30°C 25°C
25°C
(77°F)
25°C
20

Capacity
Capacity
20 (104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
(77°F)
(194.6) (125) 0.1 20
20
20
0.1 0
Contents indicated (including the recycle marking, etc.) 0
0.10
0.1
0.1 0
10
10
20
20
30
30
40
40
50
50
60
60 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) Temperature (°C) 000 0 2 4 6 8 10 12 14 16 18 20
000 10
10
10 20Temperature
20
20 3030 (°C)40
30 40
40 50
50
50 60
60
60 Storage period (mth.)
000 222 444 Storage
666 888 period
10
10
10 12(mth.)
12
12 1414
14 16
16
16 18
18
18 20
20
20
Temperature
Temperature
Temperature(°C)
(°C)
(°C)
Storage
Storage
Storageperiod
period
period(mth.)
(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-V1233P CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20
CHARGE CHARACTERISTICS FOR CYCLE USE AND BY DISCHARGE CURRENT
160
160 16.0
16.0 120
Nominal capacity (20 hour rate) 33Ah 40°C Battery voltage 120
160
160 Battery voltage 16.0
16.0
10
140
140 14.0
14.0 120
120
120 0.05CA
Length 195.6mm 0.3 Battery
Battery
Batteryvoltage
voltage
voltage 100 0.05CA
0.3 100 0.10CA
Dimensions Width 130mm 140
140
120 14.0
14.0
12.0 0.10CA
0.05CA
0.05CA
0.3
0.3 120 Charge quantity (to discharge quantity) 12.0 100
100 0.05CA
5 100 0.25CA
0.10CA
0.10CA
(h)

Charge quantity (to discharge quantity) 0.10CA

(%)
80 0.25CA

(CA)
120
120
100 12.0
12.0
10.0 0.50CA

(%)(%)
Height 180mm 25°C

(V)
80

(CA)

(%)
100 Charge
Charge Discharge
quantity
Śquantity(to(todischarge
discharge quantity)
quantity) 10.0 0.50CA

(V) (V)
Charge quantity (to discharge quantity)

(%)(%)
3 0.2 —Discharge
0.25CA
0.25CA
0.25CA

quantity
Ś—

(%)
quantity (%)
0.2 100% (0.05CA*20H) 80
80

voltage
Approx. mass 80

(CA)
(CA)

quantity
11.5kg
Duration of discharge

0.50CA
0.50CA

current (CA)
100
100 — 10.0
10.0 0.50CA

current

(V)
80 — 100% (0.05CA*20H) 8.0

Capacity
voltage
voltage (V)

(%)
Capacity (%)
— Discharge
Discharge 60 1.00CA

current
80 Discharge 8.0

Capacity
Ś—Ś
Ś 50% (0.05CA*10H)
0.2
0.2 ——50% (0.05CA*10H) 60 1.00CA

quantity
Charge quantity
Terminal M6 bolt/nut —
———100%
— 100% (0.05CA*20H)
(0.05CA*20H)

voltage
100% (0.05CA*20H)

Battery voltage
ś Charge 2.00CA

current
80
80 8.0
8.0

Capacity
Charge current
60 6.0

Capacity
60 —Charge
ś— —
—50%

— 50%
50% (0.05CA*10H)
(0.05CA*10H)
(0.05CA*10H) 6.0 60
60
60 2.00CA
1.00CA
1.00CA
1.00CA
20 hour rate 33Ah Charge voltage: 13.7V (2.28V/cell) 40 3.00CA

Charge

Battery
60 0°C 0.1 Charge voltage: 13.7V (2.28V/cell) 40 3.00CA
2.00CA
2.00CA
2.00CA

Charge
Charge

Battery
0.1 śś Charge
Charge
Charge
60
60
40 śCharge current: 0.15CA 6.0
6.0
4.0

Charge
10 hour rate 31Ah 40 Charge
Charge
Charge current:
voltage:
voltage:0.15CA
13.7V
13.7V
(2.28V/cell)
(2.28V/cell) 4.0 40
40 3.00CA
3.00CA
3.00CA

Charge
Capacity Charge voltage: 13.7V (2.28V/cell)

Battery
40

Charge

Battery
0.1
0.1 Ŝ Temperature: 25°C (77°F)

Charge
Charge
(25°C) 30 40
40
20 Temperature:
Ŝ Charge
Charge
Charge current:25°C
current: (77°F)
0.15CA
current: 0.15CA
0.15CA 4.0
4.0
2.0 20
3 hour rate 26Ah 20 2.0 20
ŜŜ
ŜTemperature:
Temperature:
Charge25°C
Temperature: 25°C
(77°F)
(77°F)
current
25°C (77°F)
1 hour rate 22Ah 0 20
20
0 Charge current
2.0
2.0
0.0 20
20
20
0 0 0.0 0
Charge
Charge
Chargecurrent
current
current 0
Fully charged battery -15°C 00 00 0
0 4
4 8
8 12
12 16
16 20
20 24
24 0.0
0.0 00-15 0 15 30 45
(min.)

10 0
-15 0 15 temperature
30
Impedance
(25°C)
7mΩ
Charge time (h) Battery (°C) 45
00 44 88 12
Charge 12
time 16
16
(h) 20
20 24
24 -15
-15
-15 000 Battery
15
15
15 temperature
30
30
30 (°C) 45
45
45
40°C 102% 5 Charge
Charge time
Chargetime (h)
time(h)
(h) Battery
Battery
Batterytemperature
temperature
temperature(°C)
(°C)
(°C)
Temperature dependency 25°C 100% 3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0
CHARACTERISTICS
20.0
1
After 3 month 91% 1 10 30 100 300 1,000
3 20.0
20.0
20.0
Self-discharge
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 15.0
15.0

(V)
(V) (V)
15.0
15.0
15.0

voltage
Terminal voltage (V)
voltage
WATT TABLE (25°C) (Wattage/battery)

voltage
10.0 1.650A
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 10.0 8.25A 1.650A
8.25A

Terminal
33.0A

Terminal
10.0
10.0
10.0 99.0A 33.0A 8.25A
8.25A 1.650A
1.650A
1.650A
9.6V 1,254 948 732 635 457 328 268 187 149 107 86.6 69.5 60.5 36.9 19.8 99.0A 8.25A

Terminal
33.0A
33.0A
33.0A
9.9V 1,182 928 721 630 452 322 262 182 148 106 85.4 68.3 60.1 36.9 19.8 99.0A
99.0A
99.0A
5.0
5.0
10.2V 1,115 899 706 619 443 321 259 170 147 105 84.2 67.7 59.7 36.9 19.8
5.0
5.0
5.0
10.5V 1,051 868 684 603 433 314 256 168 146 104 83.6 67.4 59.2 36.9 19.8
10.8V 1,001 823 663 590 421 281 233 162 137 99.4 82.5 67.1 58.8 36.9 19.8 0.0
0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.0 0
0.0
0.0 1 2 3 5 7
(min.) 10 20 40 60 2 4 6 8 10
(h) 20 40
000 111 222 333 555 (min.)
777 10 10
10 20
20
20 40
40
40 6060
60 222 444 666 (h)
888 10
10
10 20
20
20 40
40
40
AMPERE TABLE (25°C) (Ampere/battery)
(min.)
(min.)
(min.) Duration of discharge (h)
(h)
(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h Duration of discharge
9.6V 113 84.6 63.7 54.8 39.1 27.9 22.8 15.8 12.6 9.00 7.25 5.80 5.10 3.10 1.65 Duration
Durationofof
Duration discharge
ofdischarge
discharge

9.9V 106 82.9 62.7 54.4 38.6 27.4 22.2 15.5 12.5 8.85 7.15 5.70 5.05 3.10 1.65
10.2V 100 80.3 61.4 53.4 37.9 27.1 22.0 14.4 12.4 8.75 7.05 5.65 5.00 3.10 1.65
10.5V 94.3 77.5 59.5 52.0 37.0 26.8 21.8 14.3 12.3 8.70 6.98 5.63 4.95 3.10 1.65
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 89.8 73.5 57.7 50.9 36.0 24.0 19.8 13.7 11.6 8.35 6.90 5.60 4.90 3.10 1.65 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

62 63
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P067R2P FOR STANDBY POWER SUPPLIES. LC-P067R2P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type (option)
4.75 6.35 0.36A - 1.44A - 3.6A - 7.2A - 14.4A -
DIMENSIONS (MM) Control voltage 6.8V - 6.9V Discharge current
Trickle use 1.44A 3.6A 7.2A 14.4A 21.6A
Initial current 1.08A or smaller

6.35

4.5
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

3.2
(187)
(250) INFLUENCE
100 OF TEMPERATURE ON TRICKLE LIFE RESIDUAL
120 CAPACITY VS. STORAGE PERIOD
120
+1.5 +1.5 100
151-0.5 34 -0.5 Charging voltage
100100 1
1 Charging voltage 120 120
䚷 2.275V/cell 100
100
130.3 2.275V/cell

(%)
1 Charging voltagevoltage
1䚷 Charging

(%) (%)
䚷 2.275V/cell 100 100
䚷 2.275V/cell

ratio
Capacity retention ratio (%)
80

(years)

ratioratio
80

life(years)
10
10 80 5°C

Service life (years)

retention
10
100 120 80 5°C

(years)

retention
10 60 5°C (41°F)

+1.5
94 -0.5
1 Charging voltage 60 (41°F)
5°C

life life
60

retention
䚷 2.275V/cell 100 (41°F)
60 25°C (41°F)

Service
40°C 30°C

Capacity retention ratio (%)


40

Service
40 40°C 30°C 25°C

Capacity
80 40 40°C 30°C
(104°F) 25°C
(86°F) (77°F)

Capacity
10 11

Service life (years)


(104°F) (86°F) (77°F)

Service
40 (104°F) 40°C
(86°F) 30°C 25°C
1
20 5°C (77°F)

0.3

Capacity
1 60 20 20 (104°F) (41°F)
(86°F) (77°F)
20
150.2 33.2 40 0040°C 30°C 25°C
0 0 2 4 6 8 10 12 14 16 18 20
1 2 (104°F) 6 2(86°F) (77°F)
Contents indicated (including the recycle marking, etc.) 0.1 0.1
0.1 20
0
0 40 8 4 10 6 12 8 14 1016 12
Storage
18 14
period (mth.)
20 16 18 20
0 0 10 10
10 20 202030 30 3040 4050 50
60 60 0 2Storage
4 period (mth.)
6 Storage
8 period
10 12 14 16 18 20
(mth.)
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1 0 Temperature (°C)
40 50 60
Temperature (°C)
Temperature (°C) 0 Storage period (mth.)
0 10 20 30 40 50 60
0 2 4 6 8 10 12 14 16 18 20
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT 0.1 Temperature (°C) Storage period (mth.)
0 10 20 30 40 50 60
Name LC-P067R2P/P1 CONSTANT-VOLTAGE Temperature
CONSTANT-CURRENT
(°C) DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 6V CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
20
Nominal capacity (20 hour rate) 7.2Ah 160 160 8 88
40°C 160 Battery voltage
Length 151mm 10 140 160 Battery voltage 7 120
0.3 140 Battery voltage 87 120
0.3 120
Dimensions Width 34mm 0.3 160 140 Charge quantity (to discharge
Batteryquantity)
voltage 8 7 0.05CA
120 6 100 120 0.05CA

Charge current (CA)


25°C 0.10CA

(%)
Charge quantity
voltage(to discharge quantity)
5 0.3 140 140
120 Battery 76 100 0.05CA

(CA)
120 Charge quantity (to discharge quantity) 6 120 0.10CA

(%)
7 100
(h)

Height 100mm

(CA)(CA)
0.3 0.10CA

(%) (%)
100 5

quantityquantity
0.25CA

Battery voltage (V)


3 Charge (toquantity
discharge(to discharge quantity) 80 0.05CA
0.2 120 120
100 655 0.05CA

quantity
100 0.25CA

(V)
Approx. mass 1.20kg Charge quantity quantity) 0.50CA

current
6

Capacity (%)
100 100 0.10CA

quantity
80

Charge current (CA)


0.25CA

(%)(V) (V)
0.10CA
Duration of discharge

(%)
1 Discharge

current
0.2
0.2 80 4 80 0.50CA

(%)
voltage
100%1 (0.05CA*20H)
Discharge 0.50CA

(%) (%)
Terminal Faston 187/250

voltage
100 100
80 5 54

quantity
Discharge 60 0.25CA 0.25CA

Battery voltage (V)


1 1.00CA

current
0.20.2 60 80 50% (0.05CA*10H)100% (0.05CA*20H) 4 80

ChargeCharge
80

Capacity
100% (0.05CA*20H) 3 60 0.50CA 2.00CA 0.50CA
1.00CA

Capacity
20 hour rate 7.2Ah 2 Charge
1 Discharge

voltage
50% (0.05CA*10H) 60

Charge
Charge
60 80 䚷Charge Discharge
1 voltage: 6.825V (2.275V/cell)4 1.00CA
80
60 50% (0.05CA*10H) 43 3.00CA

Charge
Charge
100% (0.05CA*20H) 2.00CA
0.1 40

Capacity
Charge
䚷 22 current:
40 60 100% (0.05CA*20H) 3 60 2.00CA

Battery
Charge 0.15CA 1.00CA

Capacity
Capacity 10 hour rate 6.6Ah 50% Charge

(0.05CA*10H)
Charge voltage: 6.825V 2 60
3 (2.275V/cell)

Battery
0.1 60 䚷 䚷
50% (0.05CA*10H) 40 2.00CA 1.00CA
3.00CA

Charge
3 Temperature: 25°C (77°F)

Charge
2 Charge Charge
䚷 voltage: 0.15CA
6.825V (2.275V/cell) 3.00CA
(25°C) 3 hour rate 5.8Ah 30 0.1 60
40 䚷
Charge Charge
䚷 6.825Vcurrent:
2 Charge
voltage:
Charge (2.275V/cell)
current: 0.15CA 32 40 3.00CA 2.00CA
0.1 20 40 2 40 20

Battery

Charge 䚷 0.15CA

Temperature:
current:
3 Charge 25°C (77°F) 1
0.1 40 2(2.275V/cell)
䚷 voltage:
3 Temperature: 6.825V
25°C
Charge current (77°F) 3.00CA
1 hour rate 4.9Ah 3 䚷
Temperature: 䚷25°C (77°F)
Charge current: 0.15CA 40
20
0°C
0 0 4020
20 20 䚷
3 Temperature: 25°C Charge 0
1 current
(77°F)
211 20 0 20
Fully charged battery 0 4 8 12 20 Charge current
16 current
Charge
(min.)

200 0
Impedance
(25°C)
15mΩ 10 -15°C 0 00 0 2000 0 10
0 0
-15 15 30 45
8 Charge
1288 time
16(h)
004 44 12 Charge20
current 0 Battery temperature (°C)
0 12 20 1616 20 -15 0 -1515 030 15
45 30 45
40°C 102% 0 0 0 0 -15 0 15 30 45
8Charge 12time (h)
Charge time (h) Battery temperature (°C)
5 0 4 Charge 16
time (h) 20 Battery temperature (°C)
-15 0 Battery temperature
15 30(°C) 45
Temperature dependency 25°C 100%
3 Charge time (h) Battery temperature (°C)
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 1 7.5
Self-discharge 0.1 0.3 1.0 3 10 30 100 7.5
After 6 month 82% 7 7.5
(25°C) Discharge current (A)
After 12 month 64% 7 7.5
6.5 7.57
6.5 7
WATT TABLE (25°C) (Wattage/battery) 66 7
6.5

(V)
6.5

voltage(V)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 5.5

Terminal voltage
6.56 5.5
4.8V 215 167 110 83.5 67.1 49.2 36.0 28.2 22.3 17.3 12.3 9.60 7.69 6.40 4.19 2.30 6

(V)
(V) (V)
55 0.36A 0.36A
4.95V 202 143 93.5 79.5 64.8 48.2 35.8 27.6 21.9 17.2 12.1 9.53 7.63 6.27 4.18 2.29 6
Terminal
voltage
5.5 1.8A 1.8A 0.72A 0.72A

voltage
5.5
5.1V 189 136 91.0 75.5 63.0 47.2 34.3 26.8 20.7 16.3 11.8 9.33 7.32 6.11 4.00 2.21 4.5
4.5 3.6A 3.6A
5.25V
5.55 voltage 0.36A
44 5
172 124 86.8 72.2 60.2 45.4 33.4 26.2 19.9 15.8 11.5 9.15 7.27 6.05 3.98 2.14 Terminal
0.36A
21.6A 7.2A 7.2A 1.8A 0.72A
Terminal
21.6A 1.8A 0.72A
5.4V 154 112 82.0 69.1 57.7 43.6 31.3 24.2 18.6 14.0 10.7 8.46 6.67 5.60 3.71 2.07
4.55 0.36A
3.5
Terminal

3.5 4.5 3.6A


3.6A 1.8A 0.72A

AMPERE TABLE (25°C) (Ampere/battery) 34.54 21.6A 7.2A 3.6A


3 4 21.6A 7.2A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 2.5 4 7.2A
3.5
2.5 3.5
0 1 2 5 10 21.6A
20 40 60 2 4 6 8 10 20 40
4.8V 38.9 30.6 19.9 14.8 12.3 9.10 6.40 5.10 3.50 2.70 2.00 1.53 1.26 1.02 0.670 0.363 0 1 2 5
(min.) 10 20 40 60 2 4 (h) 6 8 10 20 40
3.53 (min.) (h)
4.95V 36.1 28.7 19.5 14.7 12.1 9.00 6.36 5.05 3.43 2.68 1.99 1.52 1.25 1.01 0.667 0.362 3 Duration of discharge
5.1V 34.2 26.9 19.0 14.4 11.9 8.90 6.30 5.00 3.36 2.61 1.97 1.51 1.24 1.00 0.660 0.361
2.53 Duration of discharge
2.5 0 1 2 5 10 20 40 60 22 44 66 88 10 20 40
5.25V 31.4 24.1 17.6 13.4 11.3 8.70 6.20 4.90 3.29 2.52 1.94 1.50 1.23 0.988 0.657 0.360 0 1 2 5
The data in this
2.5document are for descriptive purposes only10 20intended
and are not 40to make
60 or imply any guarantee 10 Regarding
or warranty. 40 and safety
20 handling
5.4V 29.0 22.3 15.7 12.5 11.0 8.40 6.10 4.80 3.20 2.40 1.90 1.48 1.20 0.972 0.650 0.358 (min.) (h)
please consult our0VRLA1technical handbook
2 5 (min.)
chapter 1. 10 20 40 60 2 4 6 8 (h)10 20 40
All mentioned values are average values (min.) Duration of discharge (h)
Duration of discharge
Duration of discharge

64 65
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P0612P FOR STANDBY POWER SUPPLIES. LC-P0612P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.6A - 2.4A - 6A - 12A - 24A -
DIMENSIONS (MM) 4.75 Control voltage: 6.8V - 6.9V Discharge current
Trickle use 2.4A 6A 12A 24A 36A
Initial current: 1.8A or smaller

6.35
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

3.2
(187)
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE RESIDUAL CAPACITY VS. STORAGE PERIOD
+1 +1.5 100
50 -0.5 151 -0.5 6.35 100 120
100 100 120 120
120

(6)
(16) (130.3) 1 Charging voltage
1 1Charging
1 Charging voltage
voltage
Charging voltage

4.5
2.275V/cell 100

(%)(%)
2.275V/cell
2.275V/cell 100 100
100

Capacity retention ratio (%)


2.275V/cell

Capacity retention ratio (%)


ratio
100 䚷 䚷䚷 120 80

(years)

ratio
10 80 8080

Service life (years)


Service life (years)
101010

(years)
1 Charging voltage 5°C

retention
(250) 5°C

+1.5
100

94 -0.5
2.275V/cell 5°C
5°C

Capacity retention ratio (%)

retention
䚷 60 60 (41°F) (41°F)

lifelife
Terminal type 6060 (41°F)
(41°F)
80

Service life (years)


10

Service
(optional) 40°C 40°C
30°C 30°C 25°C
40 40°C 30°C
5°C 25°C

Capacity
40 25°C

Service
40°C 30°C 25°C
11 1 4040 (104°F) (104°F)
(86°F) (86°F) (77°F)

Capacity
1 60 (104°F) (41°F)(77°F)
(86°F) (77°F)
(104°F) (86°F) (77°F)
(49.2) (150.2) 20 20
40 2020 40°C 30°C 25°C
1

(0.3)
(104°F) (86°F) (77°F)
0 0
0.1 0.1 20 0 0 02 04 26 84 106 128 1410 1612 1814 2016 18 20
Contents indicated (including the recycle marking, etc.) 0.10.1 0 0 2 2 4 4 6 6 8 8 1010 1212 1414 1616 1818 2020
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0 0 10 10 20 2030 3040 4050 60
50 60 Storage period (mth.)period (mth.)
Storage
00 1010 Temperature
2020 3030 0
0.1 (°C) 40
Temperature
40
(°C)
5050 6060 0 2 4 6 8 10 12 Storage 16 period
14Storage period
18 (mth.)
20 (mth.)
Temperature (°C)
0 10 20 30Temperature
40 (°C)
50 60 Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)
Name LC-P0612P/P1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 6V CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
20 160 8
Nominal capacity (20 hour rate) 12Ah 160 Battery voltage 8
160
160 Battery voltage 88 120
Length 151mm 10 0.3 160140 Battery
Batteryvoltage
voltage 8
7 120
0.3 140 140 Battery voltage 7 120
120 0.05CA
40°C 140
Charge quantity (to discharge quantity) 77
Dimensions Width 50mm 0.3140120 6 120 100
0.3 0.3 0.10CA

Charge current (CA)


Charge quantity (to discharge quantity) 7 0.05CA

Charge quantity (%)


5 120 Charge quantity (to(to
discharge quantity) 6 100 0.05CA

Battery voltage (V)


0.10CA
0.05CA

(CA)
Charge quantity discharge quantity)
Height 100mm 120
120 Charge quantity (to discharge quantity) 66 100 0.05CA
(h)

100

(%)(%)
0.25CA 0.10CA

Charge current (CA)


120100 5 0.10CA

(V)(V)
(CA)
6 100 80 0.10CA

Charge current (CA)

Charge quantity (%)


0.2 0.50CA

(%) (V)
3

Capacity (%)
Charge quantity (%)
100 5 0.25CA

Battery voltage (V)


Approx. mass 1.80kg

current
80

quantity

voltage
25°C 1 Discharge 0.25CA
100 55
Duration of discharge

0.2
100 80 100 5 4 0.25CA 0.50CA
0.25CA

(%)(%)
8080

voltage
current

quantity

voltage
100%1 (0.05CA*20H) 80
0.2 0.2 0.50CA

Capacity (%)
Terminal Faston 187/250 0.2 Discharge 60 0.50CA 1.00CA 0.50CA
80 1 Discharge50% (0.05CA*10H)
Discharge
1 1 Discharge 4

Capacity
80 608080 100% (0.05CA*20H)4 3 44 2.00CA
2 Charge 60 1.00CA

Capacity
20 hour rate 12.0Ah 100% 䚷(0.05CA*20H)
100% (0.05CA*20H)

Capacity
100% (0.05CA*20H) 60

Charge
50% (0.05CA*10H) 6060 1.00CA

Battery
60 Charge voltage: 6.825V (2.275V/cell) 3.00CA 1.00CA
1.00CA

Charge
0.1 60 60 50% (0.05CA*10H)
250% (0.05CA*10H) 3 40 2.00CA

Battery
Charge

Charge
50%
䚷 (0.05CA*10H) 3 2.00CA

Battery

Charge current: 0.15CA
406060 2 Charge 2 3 2.00CA

Charge
Capacity 10 hour rate 11.0Ah 䚷 2 Charge Charge
2䚷 Charge
䚷voltage: (77°F) 6.825V (2.275V/cell) 3
voltage: 40 3.00CA 2.00CA
3.00CA
0°C 0.1 0.1 3 Temperature:
Charge
Charge䚷6.825V
䚷 25°C
(2.275V/cell)
voltage: 6.825V (2.275V/cell) 40 3.00CA
(25°C) 0.1 40 20 40

Charge current: Charge
Charge
0.15CA current:
voltage:
䚷 䚷䚷 current: 0.15CA2
0.15CA
6.825V (2.275V/cell) 2 20 4040 3.00CA
3 hour rate 9.3Ah 30 0.1 4040 䚷
3 Temperature:
Charge
3 Charge
25°C current:25°C
Temperature:
(77°F) (77°F) 1
0.15CA 22
䚷 䚷
3 Temperature: Charge
25°C current
(77°F)
1 hour rate 8.5Ah 20 20 3 Temperature: 25°C (77°F)
1 1 20 20
0 020 Charge current Charge current0 11 0 2020
-15°C 020 4 8 12 16 20
Charge current
(min.)

Fully charged battery 0 0 0 0


Charge current
0 0 -15 0 0 15 30 45
Impedance 15mΩ 10 0 0
(25°C) 00 0 0 40 8 Charge time (h)
4 12 8 16 12 20 16 20 00 -15 00 0 Battery temperature
15 30 (°C)
45
00 4 4Charge8 time 1212 1616 2020
(h)
8 Charge -15
Battery 0 (°C) 15 30 45
40°C 102% time (h) -15 temperature
0-15 15 3030(°C)
0 Battery temperature
15 4545
5 Charge
Chargetime (h)(h)
time Battery temperature (°C)
Battery temperature (°C)
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 1 7.5
7.5
Self-discharge 0.3 1 3 10 30 100
After 6 month 82% 7
(25°C) Discharge current (A) 7 7.57.5
After 12 month 64% 7.5
6.56.5 7
77
WATT TABLE (25°C) (Wattage/battery) 6 6 6.5
6.5
6.5

Terminal voltage (V)


Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 5.55.5

Terminal voltage (V)


6
4.8V 340 279 192 149 124 91.3 68.7 52.4 35.1 27.2 19.0 14.4 12.0 10.9 6.66 3.61 66
5 5 0.6A 0.6A

(V)(V)
4.95V 325 269 186 144 121 88.3 67.5 51.8 35.0 27.1 18.9 14.4 12.0 10.9 6.66 3.61 5.5 1.2A 1.2A

Terminal voltage (V)


5.5
4.54.5 5.5
3A 3A

voltage
5.1V 304 253 181 141 118 88.3 66.9 51.2 34.5 26.9 18.7 14.4 12.0 10.8 6.60 3.61 6A 6A

voltage
5 0.6A
5.25V 278 237 171 136 115 86.0 66.3 50.1 34.2 26.6 18.4 14.3 12.0 10.8 6.60 3.60 4 455 36A 36A 12A
1.2A 0.6A
0.6A
12A 3A 1.2A
1.2A
5.4V 247 217 161 131 113 83.1 61.6 48.9 33.1 26.0 18.1 14.2 11.9 10.7 6.54 3.59 Terminal 4.5 3A3A
4.5
3.53.5 4.5 6A
Terminal
6A6A

(Ampere/battery)
3 4 44 36A 12A
AMPERE TABLE (25°C) 3 36A36A 12A
12A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 2.5 3.5
3.5
2.5
0 3.5 1 2 5 10 20 40 60 2 4 6 8 10 20 40
4.8V 61.1 50.1 34.3 25.9 21.3 15.6 11.7 8.90 5.95 4.60 3.20 2.41 2.01 1.81 1.11 0.602 03 1 2 5
(min.) 10 20 40 60 2 4 (h) 6 8 10 20 40
4.95V 58.4 48.2 33.3 25.0 20.8 15.1 11.5 8.80 5.92 4.58 3.18 2.41 2.01 1.81 1.11 0.602
33 (min.) (h)
Duration of discharge
5.1V 54.6 45.4 32.4 24.5 20.3 15.1 11.4 8.70 5.85 4.55 3.15 2.41 2.00 1.80 1.10 0.601
2.5 Duration of discharge
2.5
2.5 0 1 2 5 10 20 40 60 2 4 6 8 10 20 40
5.25V 50.0 42.6 30.6 23.6 19.9 14.7 11.3 8.50 5.80 4.50 3.10 2.40 2.00 1.80 1.10 0.600 00 11 22 55 1010 2020 4040 6060 22 4 4 6 6 8 81010 2020 4040
The data in this document are for descriptive purposes (min.)
only and are not intended to make or imply any guarantee or (h)
warranty. Regarding handling and safety (h)
(min.)
(min.) (h)
5.4V 44.5 38.9 28.7 22.7 19.4 14.2 10.5 8.30 5.60 4.40 3.05 2.38 1.99 1.79 1.09 0.598 please consult our VRLA technical handbook chapter 1.
Duration of discharge
All mentioned values are average values Duration ofof
Duration discharge
discharge

66 67
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P06200TA FOR STANDBY POWER SUPPLIES. LC-P06200TA


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
10.0A - 40.0A - 100A - 200A - 400A -
DIMENSIONS (MM) Terminal type Control voltage: 6.80V - 6.90V Discharge current
M10 Trickle use 40.0A 100A 200A 400A 600A
53 Initial current: 30.0A or smaller
Cut-off voltage 5.25V 5.10V 4.95V 4.65V 4.35V

26
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(T)
100
100 120
120
407±2 173±2

(%)
100
100 11 Charging
Charging voltage 120

ratio(%)
100 voltage 120
100
120
100
300±2 61 24 1.5 2.275V/cell
2.275V/cell

(years)

ratio
53

life(years)
Charging voltage

(%)
11 Charging voltage

ratio(%)
10 1 Charging voltage 100
100
80
100

32
10 2.275V/cell
2.275V/cell 80

68

retention
2.275V/cell

(years)

retention
5°C

ratio
life(years)
5°C
10
10 80
80

life
10 60
80
60 (41°F)
(41°F)

retention
250±2
5°C
5°C

retention
Service
Service
5°C

210±2
60

life
60
40 40°C 30°C 25°C (41°F)
(41°F)

Capacity
11 60
40 40°C 30°C 25°C (41°F)

Capacity
Service
(104°F) (86°F) (77°F)

Service
(104°F) (86°F) (77°F)
11 40
40 40°C
40°C 30°C
30°C 25°C
25°C

Capacity
20
40 40°C 30°C 25°C

Capacity
1 20
(104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
406 172 (77°F)
20
20
00
20
0.1
0.1
Contents indicated (including the recycle marking, etc.) 0 10 20 30 40 50 60 00 22 44 66 88 10
10 12 12 1414 1616 18
18 20
20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1 0
0.1
10 20 30 40 50 60
00
0
Storage
0.1 Temperature (°C) Storage period
period (mth.)
(mth.)
Temperature (°C)40
00
0 10
10
10 20
20
20 30
30
30 40
40 50
50
50 60
60
60 00
0 22
2 44
4 66
6 88 10
8 10 12
10 12 14
12 14 16
14 16
16 18
18
18 20
20
20
Storage period
Storage
Storage period (mth.)
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature
Temperature (°C)
(°C)
Temperature (°C)
Name LC-P06200TA CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 6V CHARGE CHARACTERISTICS
160
160 FOR TRICKLE USE 8.00
8.00 AND BY DISCHARGE CURRENT
120
120
20 40°C Battery
Battery voltage
voltage
Nominal capacity (20 hour rate) 200Ah 140 7.00
140
160
160 7.00
8.00
8.00 120 0.05CA
0.3
0.3 160 Battery voltage quantity)
8.00 120
100
120
100
0.05CA
0.10CA
Length 407mm 10 Charge Battery
Charge quantity
quantity (to voltage
(to discharge
Batterydischarge
voltage quantity) 0.10CA

(CA)
120 6.00

(CA) (CA)
140
120
140 7.00
6.00
7.00

(V)
(%)
140 7.00

(V) (V)
(%) (%)
Dimensions Width 173mm 0.3
0.3 0.05CA
0.05CA
0.25CA
0.05CA
0.3 Charge quantity
quantity (to
(to discharge
discharge quantity)
quantity) 100
100
80
100 0.25CA
0.10CA
0.10CA

voltage
100 Charge 5.00 80

current
5 0.50CA
0.10CA

voltage
(h)

quantity
100
120 Charge quantity (to discharge quantity) 5.00
6.00

current
120 6.00

(%)
0.50CA

quantity
(CA)

(%) (%)
Height 250mm 25°C 0.2
0.2 120 11 Discharge
Discharge 6.00

(V)
(%)
3 80 —
— 100% (0.05CA*20H)
— 100% (0.05CA*20H) 4.00 80
80 0.25CA
0.25CA
0.25CA

Capacity
100
80 — 5.00
4.00

voltage
100 5.00 60

current

Capacity
Approx. mass 33.5kg 80 0.50CA
0.50CA

quantity
Duration of discharge

60 1.00CA

voltage
100 — 5.00

current
11—
50%
50% (0.05CA*10H) 0.50CA
1.00CA

quantity
0.2 —Discharge
Discharge
(0.05CA*10H)

(%)
0.2 —

Battery
Charge
Discharge

Battery
0.2 60 122—Charge
3.00 2.00CA

Charge
Charge

Charge
Terminal M10 T-shape 60
80
80 — 100% (0.05CA*20H)
100%
—Charge
— 䚷 (0.05CA*20H) 3.00
4.00
4.00 2.00CA

Charge

Capacity
— voltage:
80 — 100%

Charge voltage: 6.85V
(0.05CA*20H)6.85V (2.28V/cell)
(2.28V/cell) 4.00 60
60 3.00CA

Capacity
0.1 ——

— 䚷50%
50%
—Charge (0.05CA*10H)
(0.05CA*10H)
current: 40
60
40 1.00CA
1.00CA
3.00CA
0.1 50%
䚷 current: 0.15CA
(0.05CA*10H) 1.00CA

Battery
20 hour rate 200Ah 40 — Charge 0.15CA 2.00

Charge
40 Charge
22 Charge 2.00 2.00CA

Battery
60 0°C 60
60 3.00
3.00 2.00CA

Charge

Charge

Temperature:
33 Charge 25°C (77°F)
60 2 䚷䚷
Temperature: 25°C (77°F) 3.00 2.00CA

Charge
Charge
Charge
䚷 voltage:
voltage: 6.85V
6.85V (2.28V/cell)
(2.28V/cell)
Capacity 10 hour rate 195Ah 0.1
0.1 Charge
䚷䚷
Charge voltage:
current:6.85V
0.15CA(2.28V/cell) 40
40
20 3.00CA
3.00CA
3.00CA
0.1 20
40
20
40
Charge

Charge current:
current: 0.15CA
0.15CA 1.00
2.00
1.00
2.00 40
20
(25°C) 3 hour rate 166Ah 30 40 䚷


Temperature:
33 Temperature:
3 Temperature:
25°C
25°C (77°F)
(77°F)
Charge
Charge
25°C (77°F)current
current 2.00
00 00 0.00 20
20
20
20 0.00
1.00
1.00 00
20
1 hour rate 120Ah 20 Charge
Charge current
current
1.00
00 44 88 12
12 16 20
16Charge 24
20current
24 -15 00 15 30 45
00
0 00 0.00
0.00 -15 15 30 45
Fully charged battery -15°C 0 Charge
Charge time
time (h) 0.00 00
(min.)

Impedance 2mΩ 10 (h) 0 Battery


Battery temperature
temperature (°C)
(°C)
(25°C)
00
0 44
4 88
8 12
12
12 16
16
16 20
20
20 24
24
24 -15
-15
-15 00
0 15
15
15 30
30
30 45
45
45
Charge time
Charge
Charge time (h)
time (h)
(h) Battery
Battery temperature
temperature (°C)
(°C)
40°C 102% Battery temperature (°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
10.00
10.00 CHARACTERISTICS
After 3 month 91% 1 10.00
10.00
1 3 10 30 100 300 1,000 10.00
Self-discharge
After 6 month 82%
(25°C) Discharge current (A) 7.50
7.50
After 12 month 64%

(V)
(V) (V)
7.50
7.50

voltage
voltage
7.50

(V)
WATT TABLE (25°C) (Wattage/battery)
5.00

voltage
5.00 50.0A 19.4A
19.4A 10.0A
10.0A

voltage
50.0A
200A

Terminal
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 200A

Terminal
5.00 600A
600A
5.00
5.00 50.0A
50.0A 19.4A
19.4A 10.0A
10.0A
4.80V 2,786 2,306 1,892 1,592 1,206 892 721 525 434 296 225 183 154 93.2 47.0 50.0A 19.4A 10.0A
200A
200A

Terminal
200A

Terminal
2.50 600A
600A
600A
4.95V 2,737 2,254 1,847 1,554 1,177 885 702 511 423 291 220 178 149 90.0 46.7 2.50
5.10V 2,565 2,204 1,781 1,498 1,139 877 683 497 417 286 215 173 145 88.9 46.1
2.50
2.50
2.50
5.25V 2,298 2,134 1,759 1,487 1,130 852 664 483 408 281 213 170 143 87.9 45.8
5.40V 2,031 1,947 1,676 1,479 1,094 840 655 476 399 275 208 167 140 86.8 45.5 0.00
0.00
00 11 22 33 55 77 10
10 20
20 40
40 60
60 22 44 66 88 10
10 20
20 40
40
0.00
0.00
0.00 (min.)
(min.) (h)
(h)
AMPERE TABLE (25°C) (Ampere/battery) 00
0 11
1 22
2 33
3 55
5 7
77 10
10
10 20
20
20 40
40
40 60
60
60 22
2 44
4 66
6 88
8 10
10
10 20
20
20 40
40
40
(min.)
(min.) Duration
Duration of
of discharge
discharge (h)
(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.) (h)
4.80V 591 485 384 318 241 179 135 99.0 81.8 57.9 44.9 37.8 31.2 19.8 10.3 Duration of
Duration
Duration of discharge
of discharge
discharge
4.95V 530 480 382 316 239 174 130 97.1 81.2 56.8 44.5 37.2 31.1 19.7 10.2
5.10V 468 467 380 312 235 173 125 96.3 80.2 56.4 44.1 36.6 31.0 19.6 10.1
5.25V 408 433 359 298 231 172 120 95.2 79.2 55.2 43.6 36.4 30.5 19.5 10.0
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
5.40V 357 379 348 290 228 148 115 85.7 75.2 53.9 43.0 36.2 30.0 19.4 9.80 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

68 69
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P122R2P FOR STANDBY POWER SUPPLIES. LC-P122R2P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type
0.011A - 0.44A - 1.1A - 2.2A - 4.4A -
DIMENSIONS (MM) 4.75 Control voltage: 13.6V - 13.8V Discharge current
Trickle use 0.44A 1.1A 2.2A 4.4A 6.6A
Initial current: 0.33A or smaller
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

6.35

3.2
INFLUENCE
100 OF TEMPERATURE ON TRICKLE LIFE RESIDUAL
120 CAPACITY VS. STORAGE PERIOD
100 120
(187)
+1.5 100 1 Charging voltage
Charging voltage 120 120
100 1
177-0.5 34±1 2.275V/cell 100
1 2.275V/cell
Charging voltage

(%)
1 Charging voltage

(%) (%)
2.275V/cell 100
(172.8) (10.1) 100

Capacity retention ratio (%)


2.275V/cell

ratio
ratioratio
(years)
120 80

(years)
100 䚷

(6)
10 䚷

2.8
80

(years)
10 1 䚷
Charging voltage 5°C
5°C
80

retention
(years)

retention
10 2.275V/cell 䚷 100 60 5°C (41°F)
(41°F)

life

Capacity retention ratio (%)


5°C

life
60 (41°F)

retention
lifelife
60 (41°F)

Service
80 40°C 30°C

Service life (years)


25°C

Service
60±1
10 䚷
40 40°C 30°C 25°C

Service
40 40°C 30°C 5°C 25°C

Capacity
(104°F) (86°F) (77°F)

Capacity
(104°F) (86°F) (77°F)
11

Service
60 40
(104°F) 40°C
(86°F) 30°C
(41°F) (77°F) 25°C

Capacity
1 20 20 (104°F) (86°F) (77°F)
40 40°C 30°C 25°C
(176) (33.5) 20 (104°F) (86°F) (77°F)
1 0
0

0.3
20 0 2 04 26 48 610 8
12 10
14 12 18
16 14 2016 18 20
Contents indicated (including the recycle marking, etc.) 0.1
0.1 0 Storage period
Storage period period (mth.)
(mth.)
Storage (mth.)
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 00 1010 20 20 30 30 40 40 50 50 60 60 0 0 2 4 6 8 10 12 14 16 18 20
0.1 Temperature (°C) (°C)
Temperature (°C) 0 2 4 6 8 10 12 14 16 period
Storage 18 20(mth.)
0.1 Temperature
0 10 20 30 40 50 60 Storage period (mth.)
0 10 20 30 40
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)50 60
Temperature (°C)
Name LC-P122R2P CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
20
Nominal capacity (20 hour rate) 2.2Ah 40°C 160 16
160 Battery voltage
16 120
Length 177mm 10 0.3 160140 Battery voltage
Battery voltage 16 14 120
120
0.3 160
140 16
14 0.05CA
Dimensions Width 34mm 25°C Charge Battery
quantityvoltage 120 100
140120 12
(to discharge quantity) 120 0.10CA 0.05CA
0.05CA

(CA)
Battery voltage 14

(%)
5 0.3 140 Charge quantity
quantity (to
(to discharge
discharge quantity)
quantity) 14 100
100 0.10CA
0.3 120 Charge 12 0.10CA

(CA)
Height 66mm
(h)

(%)
0.05CA

(CA) (CA)

(%) (%)
100 0.25CA
120100 10

Charge quantity

Battery voltage (V)


Charge quantity (to discharge quantity) 12 80 0.05CA

current
0.10CA

Charge current (CA)


3 0.50CA

Charge quantity (%)


0.2

Capacity (%)
Approx. mass 0.80kg 120
100 Charge quantity (to discharge quantity) 12
10 100 0.25CA
0.25CA
0.10CA

quantity

(V)
80

quantity
current

(%) (V)
80

current
Duration of discharge

1 Discharge 0.25CA 0.50CA


0.2 100 80

(%)
10 8 0.50CA

(%) (%)
Battery voltage (V)
80

voltage
Terminal Faston 187 0.2 100% (0.05CA*20H) 60 0.50CA 1.00CA

voltage
100 1 Discharge
Discharge 10 0.25CA

quantity

(V)
1 80

current
0.2 80 6080 8

Charge
50% (0.05CA*10H)

Capacity
1 Discharge 2.00CA

Capacity
100%
100% (0.05CA*20H)
(0.05CA*20H) 8 6 60
60 0.50CA
1.00CA

Capacity
20 hour rate 2.2Ah 2 Charge
100% (0.05CA*20H) 60 1.00CA 1.00CA

voltage
60 3.00CA

Charge
Charge
䚷1 Discharge
50% (0.05CA*10H) 40 2.00CA

Charge
Charge
Charge voltage:
50% 13.65V (2.275V/cell)
(0.05CA*10H)
0.1 60 80 50% (0.05CA*10H) 86 2.00CA 2.00CA
4060

Capacity
10 hour rate 2.0Ah 䚷2 2 Charge
2 ChargeCharge current: 0.15CA 6 4

Battery
Capacity 100%
Charge (0.05CA*20H) 60 1.00CA

Battery


䚷 3 Temperature:
Charge voltage: 13.65V
13.65V (2.275V/cell) 40 40
40 3.00CA 3.00CA
3.00CA
0°C 0.1 0.1 Charge䚷voltage: 13.65V
Charge 25°C (77°F)
(2.275V/cell)
voltage: (2.275V/cell)

Charge
Charge
(25°C) 50% (0.05CA*10H) 2.00CA
3 hour rate 1.8Ah 30 60
40 2040 䚷
Charge 䚷 0.15CA
Charge
current:

Charge current:
current: 0.15CA
0.15CA4 64 20
2 Charge 2

Battery
3 Temperature:
䚷 3 䚷䚷 25°C (77°F)Charge
Temperature:
䚷 Temperature:
3 Charge 25°Ccurrent
(77°F)
voltage:25°C (77°F)
13.65V (2.275V/cell) 40 3.00CA
1 hour rate 1.5Ah -15°C 0.1 20 䚷
Charge 2
current: 0.15CA
20 20
20
0 40
020 Charge current 0 42 0
3 Temperature:
䚷 25°CCharge current
(77°F)current
Charge
Fully charged battery 0 4 8 12 16 20 0 -15 20 0 15 30 45
(min.)

0 0 0
Impedance 70mΩ 0
(25°C) 10 0 0 200 4 8 Charge
12 time16
(h) 20 Charge current
20 -15 0
015Battery temperature
30 (°C)
45
0 4 time8(h) 12 16 20 -15 0 (°C) 15 30 45
40°C 102% 0 0
Charge
0 0 -15 temperature
Battery 0 15 30 45
5 Charge
Charge time
time (h)
(h) Battery
Battery temperature
temperature (°C)
(°C)
25°C 100%
0 4 8 12 16 20 -15 0 15 30 45
Temperature dependency
3 Charge time (h) Battery temperature (°C)
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 1 15
Self-discharge
15
0.03 0.1 0.3 1 3 10
After 6 month 82%
(25°C) Discharge current (A) 14 15
14
After 12 month 64%
13 13
15
14 14
WATT TABLE (25°C) (Wattage/battery) 12 12
14 13

voltage (V)
Terminal voltage (V)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
11 11
9.6V 132 104 68.1 52.0 43.6 32.5 23.0 18.4 12.6 9.77 7.27 5.59 4.61 3.71 2.46 1.33 13
12
10 10 0.11A 0.11A

(V)
9.9V 123 97.8 66.7 51.7 42.9 32.2 22.8 18.4 12.4 9.70 7.24 5.55 4.58 3.69 2.45 1.33

(V) (V)
12 0.55A 0.55A 0.22A 0.22A

Terminal
9 11
voltage
voltage
10.2V 113 91.6 65.0 50.6 42.2 31.8 22.6 18.0 12.1 9.44 7.16 5.51 4.54 3.66 2.42 1.32 9 1.1A 1.1A
10.5V 101 82.1 60.2 47.1 40.1 31.1 22.2 17.6 11.9 9.12 7.05 5.48 4.50 3.62 2.41 1.32 voltage 11
10 0.11A
0.11A
8 8 2.2A 2.2A
6.6A 6.6A
0.55A 0.22A
Terminal
10.8V 85 72.6 53.7 43.9 39.0 30.0 21.9 17.3 11.5 8.68 6.91 5.40 4.39 3.56 2.38 1.31 0.55A 0.22A
Terminal

7 10
79 1.1A
1.1A
0.11A
0.55A 0.22A
Terminal

AMPERE TABLE (25°C) (Ampere/battery) 6


68
9 2.2A
2.2A 1.1A
6.6A
6.6A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 5 8 2.2A
057 1 2 5 10 20
6.6A 40 60 2 4 6 8 10 20 40
9.6V 11.9 9.35 6.08 4.52 3.76 2.78 1.96 1.56 1.07 0.825 0.611 0.468 0.385 0.309 0.205 0.111 0 1 2 5
(min.) 10 20 40 60 2 4 (h) 6 8 10 20 40
9.9V 11.0 8.77 5.96 4.49 3.70 2.75 1.94 1.56 1.05 0.819 0.608 0.464 0.382 0.308 0.204 0.111 76 (min.) (h)
Duration of discharge
10.2V 10.2 8.22 5.81 4.40 3.64 2.72 1.93 1.53 1.03 0.798 0.602 0.461 0.379 0.306 0.202 0.110 Duration of discharge
65
10.5V 9.0 7.36 5.38 4.09 3.45 2.66 1.89 1.50 1.01 0.770 0.593 0.458 0.376 0.302 0.201 0.110
The data in this0document 5
1 are for 2descriptive purposes 20 intended
10and are not
only 40 to make
60 or imply
2 any guarantee
4 6 or 8 10
warranty. 20
Regarding 40
handling and safety
10.8V 7.6 6.51 4.80 3.82 3.36 2.57 1.86 1.47 0.98 0.733 0.581 0.452 0.367 0.297 0.199 0.109 5 (min.)
(min.) (h)
(h)
please consult 0our VRLA
1 technical2 handbook chapter
5 1. 10 20 40 60 2 4 6 8 10 20 40
All mentioned values are average values (min.) Duration of
of discharge
discharge (h)
Duration
Duration of discharge
70 71
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P123R4P FOR STANDBY POWER SUPPLIES. LC-P123R4P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type
0.17A - 0.68A - 1.7A - 3.4A - 6.8A -
DIMENSIONS (MM) 4.75 Control voltage: 13.6V - 13.8V Discharge current
Trickle use 0.68A 1.7A 3.4A 6.8A 10.2A
Initial current: 0.51A or smaller
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

6.35

3.2
INFLUENCE
100 OF TEMPERATURE ON TRICKLE LIFE RESIDUAL
120 CAPACITY VS. STORAGE PERIOD
(187) 100 120
Charging voltage
1
120 120
100
100
+1.5 Charging
1 voltage
2.275V/cell 100
134-0.5 67±1 1 1 Charging
Charging voltage
voltage 100

Capacity retention ratio (%)


2.275V/cell 100
2.275V/cell
2.275V/cell 100

(%)
(64.9) (57) 80

(years)

Capacity retention ratio (%)


120

(%)
100 䚷

(2.8)
(53.2) 10 80

ratio
(years)
䚷 80 5°C

(years)
Charging䚷voltage
1010
1
80

ratio
life(years)
(6)
10 2.275V/cell 䚷 100 60 5°C 5°C(41°F)

retention
lifelife
5°C

Capacity retention ratio (%)


60 60 (41°F) (41°F)

retention
60 (41°F)

Service
80 40°C 30°C

Service life (years)


25°C

life
10 䚷 40

60±1

Service
40°C
(104°F) 30°C

Service
40 40 40°C 30°C 5°C25°C
(86°F) 25°C(77°F)
1

Service
60 (104°F) 40°C
(104°F)
(86°F) 30°C
(86°F)
(41°F)
(77°F) 25°C
(77°F)

Capacity
11 40
20 (104°F) (86°F) (77°F)

Capacity
1 20 20 40°C 30°C 25°C
40
(133) (66.5) 20 (104°F) (86°F) (77°F)

(0.3)
1 0
0
20 0 02 4 0 6 2 8 4 10 6 12 814 10 16 12 18 20 14 16 18 20
Contents indicated (including the recycle marking, etc.) 0.10.1 0 0 2 4 6 8 10 12 14 16 18 20
0.1 0 2 Storage
4 period Storage
(mth.)
6Storage 10period
8 period 12 (mth.)
14 16 18 20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0 0 10 10 20 20 30 3040 4050 50
60 60 0 (mth.)
0.1 0 10 Temperature
20 30 40 50 60 0 2 4 6 8 10 12 Storage
14 16 period
18 20
Temperature
(°C) (°C) (mth.)
0.1 0 10 20 30 (°C)
Temperature 40 50 60 Storage period (mth.)
0 10 20 Temperature
30 40 (°C) 50 60
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)
Name LC-P123R4P CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20 CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
40°C 160 16
Nominal capacity (20 hour rate) 3.4Ah 160 Battery voltage 16
160 16 120
Length 134mm 10 0.3 160140 Battery voltage
Battery voltage 16
14 120
0.3 160 140 16 14 120 0.05CA
0.3 120140 Charge quantity
Battery(to discharge quantity)
voltage 14 120 100
14 12
Battery voltage

current (CA)
Dimensions Width 67mm 0.10CA

(%)
0.3 140 Charge quantity (to discharge quantity) 120 0.05CA
5 0.3 140120 14 12 100 0.05CA

(CA)
Charge quantity (to discharge quantity) 0.10CA

(%)
100

Battery voltage (V)


(h)

25°C 120 12 0.05CA 0.25CA

Charge quantity
Height 66mm

current(CA)
100 10 0.10CA

quantity(%)
Charge quantity (to discharge quantity) 100 80
0.2 120 12 0.05CA

Charge current (CA)


0.10CA 0.50CA

Charge quantity (%)


Charge quantity (to discharge quantity)

Capacity (%)
(V)
3 120100 12 10 100 0.25CA

Charge (CA)
0.10CA

(%) (V)
(%)
Approx. mass 1.15kg 1 Discharge
8080

Chargequantity
100 10 0.25CA

Battery voltage (V)


Chargecurrent
0.2100 80 10 8
Duration of discharge

0.25CA 0.50CA

Capacity (%)
voltage
0.2 0.2
100% (0.05CA*20H) 80 60 0.50CA

(%) (%)
0.50CA 1.00CA

voltage
(V)
Terminal

Charge quantity
Faston 187 100 80 1 Discharge
10 8 0.25CA

current
50%1 (0.05CA*10H)
Discharge
0.2 80 60 80 1 Discharge
2 Charge 100% (0.05CA*20H)8 6 8 80 2.00CA 0.50CA

voltage
6060 1.00CA

Capacity
Capacity
20 hour rate 3.4Ah 100%
䚷 100% (0.05CA*20H)
(0.05CA*20H) 60 1.00CA 3.00CA
0.1 Charge voltage:
1 Discharge 13.65V (2.275V/cell)
50% (0.05CA*10H) 40 1.00CA

Charge
Charge
60 0°C 80 60 50%䚷(0.05CA*10H)
50% (0.05CA*10H) 8 6 2.00CA

Battery
Charge current: 0.15CA 2.00CA
60 40 4 2.00CA

Capacity
60 Charge
100% (0.05CA*20H) 6
(77°F)13.65V (2.275V/cell)6
2

Battery
Capacity 10 hour rate 3.1Ah 2 Charge 2 Charge
䚷 Temperature:
3 䚷 䚷Charge 25°C
voltage:
60 3.00CA 1.00CA
3.00CA
4040

Charge
0.1
0.1 0.1 Charge voltage:

50% 13.65V (2.275V/cell)
(0.05CA*10H)
Charge voltage: 13.65V (2.275V/cell) 40 20 3.00CA
2.00CA
60 40 64 4

Battery
(25°C) 40 20 䚷 䚷Charge
Charge2 current:
Charge 0.15CAcurrent: 0.15CA
4 2
3 hour rate 2.8Ah 30 40 Charge current:
䚷 0.15CA
Charge25°C
current
0.1
Temperature:
3 䚷 䚷3 䚷 25°Cvoltage:
3Charge
(77°F)
Temperature:
Temperature:
䚷 13.65V (77°F)
(2.275V/cell)
25°C (77°F) 40 3.00CA
20
1 hour rate 2.3Ah 0 20 40
0 20 Charge current: 0.15CA2
䚷 4 2 0 0 2020
-15°C 20
0 4 8 3 12
Charge current
16 25°C
Temperature:
䚷 Charge current 2
20(77°F)
0 Charge current -15 0 15 30 45
Fully charged battery 0 0 0 20
(min.)

Impedance 50mΩ 00 20
0 00 4 8 Charge
12 time
16(h) 20 0 0 Battery temperature (°C)
(25°C) 10 20 Charge current -15 0 0 15 30 45
00 4 4 8 (h) 8 12
12 1616 2020
40°C 102% 0 0 Charge time 0 0 -15temperature
Battery
-15 0 0 (°C) 15 15 30 30 45 45
5 0 4 Charge
8Charge time(h)
12time (h)
16 20 Battery
Battery temperature
temperature (°C)(°C)
-15 0 15 30 45
Temperature dependency 25°C 100%
3 Charge time (h) Battery temperature (°C)
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
15
After 3 month 91% 1 15
Self-discharge 0.03 0.1 0.3 1 3 10 14
After 6 month 82%
(25°C) Discharge current (A) 14 1515
After 12 month 64% 13
1315
12
14
14

voltage (V)
WATT TABLE (25°C) (Wattage/battery) 1214
1113
13

Terminal voltage (V)


Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 11
9.6V 204 161 105 80.4 67.4 50.3 35.5 28.4 19.6 15.0 11.3 8.63 7.13 5.80 3.81 2.06
13
1012
12 0.17A
0.34A

(V)
10 0.17A

voltage (V)
Terminal voltageTerminal
9.9V 190 151 103 79.8 66.3 49.7 35.3 28.4 19.2 14.9 11.2 8.58 7.07 5.78 3.80 2.05 0.85A 0.34A
12911
11 1.7A 0.85A

Terminal voltage
(V)
10.2V 175 142 100 78.2 65.2 49.2 34.9 27.8 18.8 14.5 11.1 8.52 7.01 5.73 3.76 2.05 9 1.7A
11810 10.2A 3.4A 0.17A
0.17A
10.5V 155 127 93 72.8 61.9 48.1 34.4 27.3 18.4 14.0 11.0 8.46 6.96 5.66 3.74 2.04 8 10 10.2A 3.4A 0.34A
0.34A
10.8V 131 112 83 67.9 60.3 46.4 33.8 26.7 17.8 13.4 10.7 8.46 6.79 5.66 3.68 1.98 Terminal
7
0.85A
0.85A 0.17A
710 99 1.7A
1.7A 0.34A
0.85A
6
69
AMPERE TABLE (25°C) (Ampere/battery) 88 10.2A
10.2A 3.4A
3.4A 1.7A
5
58 3.4A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
0 077
10.2A
1 1 2 2 5 5 10 10 20 20 40 40
60 60 2 2 4 64 6 8 1020
8 10 2040 40
9.6V 18.4 14.4 9.40 6.99 5.81 4.30 3.02 2.41 1.66 1.26 0.949 0.722 0.595 0.484 0.318 0.171 (min.)
(min.) (h) (h)
7 66
9.9V 17.0 13.6 9.21 6.94 5.71 4.25 3.00 2.41 1.62 1.26 0.945 0.718 0.590 0.482 0.316 0.171 Duration of discharge
Duration of discharge
10.2V 15.7 12.7 8.97 6.80 5.62 4.20 2.97 2.36 1.59 1.22 0.935 0.713 0.586 0.478 0.313 0.170 6 55
10.5V 14.0 11.4 8.31 6.33 5.34 4.11 2.93 2.31 1.56 1.18 0.921 0.708 0.581 0.472 0.312 0.170 10 00 11 22 55 10 2020 4040 6060 22 4 4 6 6 8 10
8 10 20 20 40 40
The data in this
5 document are for descriptive purposes
(min.) only and are not intended to make or imply any guarantee or warranty.
(h) Regarding handling and safety
10.8V 11.8 10.1 7.41 5.90 5.19 3.97 2.88 2.27 1.51 1.13 0.897 0.708 0.567 0.472 0.307 0.165 please consult 0our VRLA (min.) (h)
1 2
technical handbook 5
chapter 1. 10 20 40 60 2 4 6 8 10 20 40
All mentioned values are average values (min.) Duration of discharge (h)
Duration of discharge
Duration of discharge
72 73
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P127R2P FOR STANDBY POWER SUPPLIES. LC-P127R2P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
6.35 0.36A - 1.44A - 3.6A - 7.2A - 14.4A -
DIMENSIONS (MM) 4.75 Terminal type Control voltage: 13.6V - 13.8V Discharge current
Trickle use 1.44A 3.6A 7.2A 14.4A 21.6A
(option) Initial current: 1.08A or smaller

6.35

4.5
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

3.2
(187)
(250) INFLUENCE
100 OF TEMPERATURE ON TRICKLE LIFE RESIDUAL
120 CAPACITY VS. STORAGE PERIOD
100 120
100 Charging voltage
1 120 120
+1.5 +1.5 100 100
151-0.5 64.5-0.5 Charging
1
2.275V/cell voltage
1 Charging voltage 100

(%) (%)
Charging
1 2.275V/cell voltage 100
100

Capacity retention ratio (%)


(65.15) (48) 2.275V/cell

(6)

(years)
2.275V/cell

Capacity retention ratio (%)


80

ratio ratio
100 10 䚷 120

(years)
80

Service life (years)


䚷 80
1010 䚷 voltage 5°C

(years)
80

retention
1 Charging 䚷 5°C(41°F)
10 100 60 5°C

life
2.275V/cell
60 5°C
(41°F)

Capacity retention ratio (%)


lifelife
60 (41°F)

+1.5
94 -0.5

retention
Service
60 25°C (41°F)

Service life (years)


80 40 40°C 30°C

Service
10 䚷
40 40°C 40°C
30°C 30°C 25°C 25°C

Capacity
1 40 (104°F) 5°C(86°F) (77°F)

Service
1 1 60 40 40°C
(104°F) (104°F)
(86°F) 30°C
(86°F)
(41°F)(77°F) 25°C
(77°F)
20

Capacity
(104°F) (86°F)

(0.3)
1 20 20 (77°F)
40 40°C 30°C 25°C
20 (104°F) (86°F)
(150.2) (63.7) 1
0
0 (77°F)
0
0.1
20 0 2 0 04 2 26 4 48 610 6 128 1410 1612 1814 20 16 18 20
8 10 12 14 16 18 20
Contents indicated (including the recycle marking, etc.) 0.10.1 0 Storage period (mth.)
0
0 0 10
10 10 20 30 30 40 40 50
20 20 50 60 0 2Storage
4 period
6 (mth.)
Storage 8period
10 (mth.)
12 14 16 18 20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0)
0.1 30 40 50 60 60 0
Temperature
Temperature (°C) (°C) 0 2 4 6 8 10 12 14 16 period
Storage 18 20(mth.)
0.1 0 10 Temperature
20 30 (°C) 40 50 60
Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT 0 10 20 30 40 (°C)50
Temperature 60
Temperature (°C)
Name LC-P127R2P/P1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20
CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
Nominal capacity (20 hour rate) 7.2Ah 160160 16 16
40°C 160 Battery voltage 16 120
10 Battery voltage 120
Length 151mm 0.3 140
160 Battery voltage
16 14 120
0.3
0.3 160
140
140 16
14
14
Dimensions Width 64.5mm Battery (to
Charge quantity voltage
discharge quantity) 0.05CA
25°C 120 Battery voltage 12 120 100 120 0.05CA

Charge current (CA)


0.10CA

Charge quantity (%)


5 0.3 140 120
140
Chargequantity
quantity(to
(todischarge 14
dischargequantity)
quantity)
12
14 100 0.05CA
0.3 Charge

(CA)
100 0.10CA

(%)
120 12

Battery voltage (V)


(h)

(CA)(CA)
Height 100mm 0.10CA

(%) (%)
0.05CA 0.25CA

(V)
100
120 Charge quantity (to discharge quantity)
12 10 100 80 0.05CA

(V) (V)
Charge current (CA)
3 0.10CA

Charge quantity (%)


0.2 Charge quantity (to discharge quantity) 0.50CA

quantity
100 0.25CA

Capacity (%)
Approx. mass 120
100 12
10

current
2.30kg 0.10CA

quantity
0.210080100 10 8080 0.25CA

Battery voltage (V)

voltage
current
1 Discharge
Duration of discharge

Capacityvoltage
0.50CA

(%) (%)
0.2 10 8 0.25CA 0.50CA

Capacity (%)
100% (0.05CA*20H)
Discharge 80
Terminal Faston 187/250 0.2 11 Discharge 60 0.50CA 1.00CA

quantity
0.25CA

(%)
80
100 8
810

current
50% (0.05CA*10H)
100%(0.05CA*20H)
(0.05CA*20H)
0.2 8060 80 80
1 Discharge

voltage

Capacity
100% 2.00CA 0.50CA
20 hour rate 7.2Ah 2 Charge
100% (0.05CA*20H)
50% (0.05CA*10H) 8 6 6060 1.00CA
1.00CA

Charge
Charge
1 Discharge
50% (0.05CA*10H) 60

Battery
Charge voltage: 13.65V (2.275V/cell) 1.00CA

Charge
60

Charge
50%䚷 3.00CA

Battery
0.1 80
60 (0.05CA*10H)
Charge
2 Charge 8
66 40 2.00CA
2.00CA
6040 60 Charge
2 100%
current:(0.05CA*20H)
0.15CA

Capacity
10 hour rate 6.6Ah 2 Charge
䚷 6(2.275V/cell)
4 2.00CA
Capacity Charge

Charge voltage:
voltage: 13.65V
13.65V (2.275V/cell) 60 1.00CA
3.00CA
3.00CA
0.1 4040
Charge
3 䚷 䚷
Temperature:
50%
voltage: 25°C (77°F)
(0.05CA*10H)
13.65V (2.275V/cell)

Charge
3.00CA

Charge
0.1 0.1

Battery
Charge
Charge current:0.15CA
current: 0.15CA 40 2.00CA
(25°C) 3 hour rate 5.8Ah 30 40
4020 60
40
Charge
䚷 䚷
current:
2 䚷Charge0.15CA
4(2.275V/cell) 464 20
33 䚷
Temperature:
3 䚷 䚷Temperature:
Temperature:
䚷 25°C (77°F)
Charge voltage: 25°C
25°C
13.65V(77°F)
(77°F) 2 3.00CA
0.1 Charge current 40
1 hour rate 4.9Ah 0°C 20 0 40
20
Charge current: 0.15CA
䚷 20 2020
0 20 Temperature:
3 䚷 25°C
Charge current
2 0
(77°F)current
Charge
242 0
Charge current
Fully charged battery 0 4 8 12 16 20
(min.)

Impedance 24mΩ 0 0 0 0 0 -15 20 0 15 30 45


(25°C) 10 -15°C 0
2000 4 8 12 16 20 020 00
Charge time (h) Battery temperature (°C)
00 44 88 12
12 16Charge
16 20
20 current -15 0 15
-15 temperature
-15
30
0 0 (°C) 1515
45
30 30 45 45
40°C 102% 0 0 Charge time (h) 0 Battery
0
5 Chargetime
Charge time(h)
(h) Battery
Battery temperature
temperature (°C)
(°C)
0 4 8 12 16 20 -15 0 15 30 45
Temperature dependency 25°C 100%
3 Charge time (h) Battery temperature (°C)
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 1 15
Self-discharge
15
After 6 month 82% 0.1 0.3 1.0 3 10 30 100
(25°C) 14
Discharge current (A) 14 15
After 12 month 64%
131315
14
WATT TABLE (25°C) (Wattage/battery) 121214
13 13

Terminal voltage (V)


Terminal voltage (V)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
1111
9.6V 430 335 220 167 134 98.4 72.1 56.5 44.6 34.7 24.7 19.2 15.4 12.8 8.39 4.60 13
12
12

(V)
(V) (V)
1010 0.36A 0.36A
9.9V 405 287 187 159 130 96.4 71.6 55.1 43.7 34.4 24.5 19.1 15.3 12.5 8.35 4.59 12
11

voltage
11 1.8A 1.8A 0.72A 0.72A

voltage
10.2V 379 273 182 151 126 94.3 68.6 53.6 41.4 32.5 23.5 18.7 14.6 12.2 8.00 4.43 99 3.6A 3.6A
10
11 0.36A
10.5V 343 248 174 144 120 90.8 66.8 52.4 39.8 31.5 23.0 18.3 14.5 12.1 7.96 4.42 voltage
Terminal
Terminal 88
10 7.2A 7.2A 1.8A 0.72A
0.36A
21.6A21.6A 1.8A 0.72A
10.8V 308 223 164 138 115 87.2 62.6 48.4 37.2 28.1 21.4 16.9 13.3 11.2 7.41 4.13 109 0.36A
7 9 3.6A
3.6A
7
Terminal

1.8A 0.72A
6 98 7.2A
6 8
AMPERE TABLE (25°C) (Ampere/battery) 21.6A 7.2A 3.6A
21.6A
5 7
50 87
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 7.2A
1 2 5 10 21.6A
20 40 60 2 4 6 8 10 20 40
9.6V 38.9 30.6 19.9 14.8 12.3 9.10 6.40 5.10 3.50 2.70 2.00 1.53 1.26 1.02 0.670 0.363 0 1 2 5
(min.) 10 20 40 60 2 4 (h) 6 8 10 20 40
9.9V 36.1 28.7 19.5 14.7 12.1 9.00 6.36 5.05 3.43 2.68 1.99 1.52 1.25 1.01 0.667 0.362
766 (min.) (h)
Duration of discharge
10.2V 34.2 26.9 19.0 14.4 11.9 8.90 6.30 5.00 3.36 2.61 1.97 1.51 1.24 1.00 0.660 0.361 655 Duration of discharge
0 1 2 5 10 20 40 60 2 4 6 8 10 20 40
10.5V 31.4 24.1 17.6 13.4 11.3 8.70 6.20 4.90 3.29 2.52 1.94 1.50 1.23 0.988 0.657 0.360 0 1 2 5(min.) 10 20 40 60 2 4 6 warranty.
8 10 Regarding
20 40
The data in this
5 document are for descriptive purposes only and are not intended to make or imply any guarantee or (h) handling and safety
10.8V 29.0 22.3 15.7 12.5 11.0 8.40 6.10 4.80 3.20 2.40 1.90 1.48 1.20 0.972 0.650 0.358 (min.) (h)
please consult our0 VRLA
1 technical handbook
2 chapter
5 1. 10 20 Duration 60
40 of discharge 2 4 6 8 10 20 40
All mentioned values are average values (min.) Duration of discharge (h)

Duration of discharge

74 75
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-PA1212P FOR STANDBY POWER SUPPLIES. LC-PA1212P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type (option)
4.75 6.35 0.6A - 2.4A - 6A - 12A - 24A -
DIMENSIONS (MM) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 2.4A 6A 12A 24A 36A
Initial current: 1.8A or smaller

6.35

4.5
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

3.2
(187)
(250) INFLUENCE
100 OF TEMPERATURE ON TRICKLE LIFE RESIDUAL
120 CAPACITY VS. STORAGE PERIOD
100 120
100
100 Charging voltage
1 120 120
100
2.275V/cell
1 Charging
1 Charging voltage
voltage 100

(%)
1 Charging voltage
+1.5 +1.5 2.275V/cell 100 100
151-0.5 98 -0.5 2.275V/cell
2.275V/cell

(%)
80

(years)

retention ratio
Capacity retention ratio (%)

ratio(%)
100 10 120
13.5±0.75 80

(years)
䚷 䚷 80 5°C

Service life (years)


80

life(years)
1010 䚷

retentionratio
10 1 Charging voltage 60 5°C 5°C(41°F)
100

life
2.275V/cell 5°C

(6)
60 60 (41°F) (41°F)

Capacity retention ratio (%)

retention
60 25°C (41°F)

Service
40°C 30°C

life
80

Service life (years)


10
䚷 40

Service
40°C 30°C
40°C
(104°F) 30°C
5°C 25°C
(86°F) 25°C(77°F)
1 40

Capacity
40

Service
40°C
(104°F) (104°F)
(86°F) (41°F)30°C 25°C

+1.5
94 -0.5
1 1 60 40 (86°F)(77°F) (77°F)

Capacity
1 20 (104°F) (86°F) (77°F)

Capacity
20 20 40°C 30°C 25°C
40 20 (104°F)
1 (86°F) (77°F)
0
0 0
0.1 20 0 02
04
2
6
4
8
6 8 10 12 14 16 18 20
10 12 14 16 18 20
Contents indicated (including the recycle marking, etc.) 0.1 0 2 4 6 Storage
8 10 12(mth.)
14 16 18 20
0.1 0 period
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0
0.1 10 10 20 20 30 30 40 40 50 5060 60
0
0 2Storage
4 period
6 8
(mth.) 10
Storage period (mth.)
12 14 16 18 20
0 10 20 30 (°C)40
Temperature 50 60
0.1 0 10 Temperature
20 (°C)
30 40 50 60 0 2 4 6 8 10 12 14 Storage
16 period
18 20(mth.)
Temperature (°C)
0 10 20 Temperature
30 40 (°C)
50 60 Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Temperature (°C)
Name LC-PA1212P/P1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20 CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
Nominal capacity (20 hour rate) 12Ah 40°C 160160 16 16
160 Battery voltage
Battery voltage 16 120
Length 151mm 10 0.30.3160140
160 Battery voltage 16 14 120
140 16 14 120
Dimensions Width 98mm 0.3 140 Charge quantity (to dischargevoltage
Battery Battery
voltage quantity) 14 0.05CA
25°C 0.3 0.3140120 12 120 100 120 0.05CA

(CA)
Charge quantity (to discharge quantity)

Charge quantity (%)


140 14 14 100 0.10CA
5 120 12

(CA)
0.05CA

(%)
0.10CA

Battery voltage (V)


Charge quantity (to discharge quantity)
120 12 100
(h)

Height

(CA)
100mm

(%)(%)
0.10CA

(V) (V)(V)
100 Charge quantity (to discharge quantity) 10 0.05CA 0.25CA 0.05CA

current
Charge quantity (to discharge quantity) 100
0.2 120 120 12

Charge current (CA)


80

Charge quantity (%)


0.10CA

quantity
3 12 100

(CA)
100 10 0.25CA

current
0.50CA 0.10CA

Capacity (%)
voltage
Approx. mass 3.65kg 80

Battery voltage (V)


quantity
0.2 80100 10 0.25CA

current
0.50CA
Duration of discharge

1 Discharge

Capacityvoltage

(%)
8 80
0.2 0.2
100 10 80 0.25CA 0.50CA

(%)(%)
quantity
100% (0.05CA*20H)
1 Discharge 0.25CA
Terminal 100 10

current
Faston 187/250 80 8 60 0.50CA 1.00CA

(%)
voltage
80

Charge
0.2 80 60 80 1 Discharge

Capacity
1 Discharge50% (0.05CA*10H)
100% (0.05CA*20H) 8 0.50CA
(0.05CA*20H)8 6 60 2.00CA 1.00CA

Capacity
100%

Charge
Charge
20 hour rate 12.0Ah 2 Charge
60

Battery
100% (0.05CA*20H)
1 Discharge
50% (0.05CA*10H) 1.00CA
60 0°C 80 䚷Charge 8 60 1.00CA 3.00CA

Charge
60

Charge
0.1 voltage: 13.65V (2.275V/cell) 6 2.00CA

Battery
50%
50% (0.05CA*10H) (0.05CA*10H) 40

Capacity
60 60 Charge
100%
䚷 22 Charge (0.05CA*20H)
0.15CA 6 6 2.00CA
60 2.00CA
0.1 40 2 ChargeCharge 4 1.00CA
10 hour rate 11.0Ah current:
䚷Charge
Capacity 3.00CA

Charge
Charge
voltage: 13.65V (2.275V/cell) 40

Battery
䚷Charge
3 䚷 50%
䚷Charge
Temperature: (0.05CA*10H)
25°C (77°F) 3.00CA 3.00CA
0.1 0.1 60
40
voltage:
䚷 13.65V
Charge (2.275V/cell)
voltage:
current:13.65V
0.15CA (2.275V/cell) 6
4 40 40 2.00CA
(25°C) 3 hour rate 9.3Ah 30 40 20 40 2䚷 Charge
䚷Charge current: 0.15CA
Charge current: 0.15CA 4 2 4 20
0.1 3 䚷 3䚷
Temperature: 䚷Temperature:
Charge voltage:
25°C (77°F) 25°C
13.65V (77°F)
(2.275V/cell) 40 3.00CA
3 䚷Temperature: Charge
25°Ccurrent
(77°F)
1 hour rate 8.5Ah -15°C 20 040 20 䚷Charge current: 0.15CA 2 42 20 20
0 20 3 䚷Temperature:
Charge current 25°C 0
(77°F)current
Charge 2 0 20
0 4 8 12 16 20
Charge current
20
Fully charged battery 0 200 0 20
(min.)

0
00
Impedance 18mΩ 0 -15 0 0 15 30 45
(25°C) 10 0 0 40 84 Charge12 8 time 16 (h)12 20 16 16Charge current 0
20 0 Battery temperature (°C)
0 4 8 12 20 -15 0
-15 15 30 45
0 0 Charge time (h)
Charge time(h) (h)16
0 0-15
Battery 0 0 (°C)
temperature 1515 30 30 45 45
40°C 102% 0 4 8
Charge 12
time 20 Battery temperature (°C)
5 -15 0Battery temperature
15 (°C)
30 45
Temperature dependency 25°C 100% Charge time (h)
3 Battery temperature (°C)
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 15
1 15
Self-discharge 0.3 1 3 10 30 100
After 6 month 82% 1415
(25°C) Discharge current (A) 14 15
After 12 month 64%
13 1315
14 14
WATT TABLE (25°C) (Wattage/battery) 12 1214
13 13

Terminal voltage (V)


Terminal voltage (V)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 11 1113
9.6V 679 559 384 298 247 183 137 105 70.3 54.5 38.1 28.8 24.1 21.7 13.3 7.22 12
0.6A 0.6A
10 10 1.2A

(V)
1.2A

(V) (V)
9.9V 649 537 373 288 241 177 135 104 69.9 54.2 37.8 28.8 24.1 21.7 13.3 7.22 12
11
3.0A 3.0A

voltage
9 9 6.0A 6.0A
10.2V 607 506 363 282 235 177 134 102 69.1 53.9 37.5 28.8 24.0 21.6 13.2 7.21 12.0A 12.0A
11
10
0.6A
0.6A
voltage
10.5V 556 475 343 271 231 172 133 100 68.5 53.3 36.9 28.7 24.0 21.6 13.2 7.20 36.0A 36.0A 1.2A
1.2A
8 8 3.0A
3.0A
Terminal 0.6A
10.8V 495 434 321 261 225 166 123 98 66.1 52.1 36.3 28.4 23.8 21.5 13.1 7.18 10 6.0A
6.0A 1.2A
7 79 12.0A
12.0A 3.0A
Terminal

98 36.0A
36.0A 6.0A
6 12.0A
AMPERE TABLE (25°C) (Ampere/battery) 6
36.0A
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 5 87
05 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
9.6V 61.1 50.1 34.3 25.9 21.3 15.6 11.7 8.90 5.95 4.60 3.20 2.41 2.01 1.81 1.11 0.602
760 1 2 4
(min.) 6 8 10 20 40 60 2 4 (h) 6 8 10 20 40
9.9V 58.4 48.2 33.3 25.0 20.8 15.1 11.5 8.80 5.92 4.58 3.18 2.41 2.01 1.81 1.11 0.602 (min.) (h)
Duration of discharge
10.2V 54.6 45.4 32.4 24.5 20.3 15.1 11.4 8.70 5.85 4.55 3.15 2.41 2.00 1.80 1.10 0.601 65 Duration of discharge
10.5V 50.0 42.6 30.6 23.6 19.9 14.7 11.3 8.50 5.80 4.50 3.10 2.40 2.00 1.80 1.10 0.600 00 11 22 44 66 88 10
10 20
20 4040 6060 22 44 6 6 8 81010 2020 40 40
5 document are for descriptive purposes
The data in this (min.)only and are not intended to make or imply any guarantee or (h)
(min.) warranty.
(h) Regarding handling and safety
10.8V 44.5 38.9 28.7 22.7 19.4 14.2 10.5 8.30 5.60 4.40 3.05 2.38 1.99 1.79 1.09 0.598 0 VRLA1 technical2handbook 4chapter
please consult our 6 1. 8 10 20 40 60 2 4 6 8 10 20 40
(min.) Duration
Durationofof
discharge
discharge (h)
All mentioned values are average values
Duration of discharge

76 77
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-PA1216P FOR STANDBY POWER SUPPLIES. LC-PA1216P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
Terminal type (option)
0.800A - 3.20A - 8.00A - 16.0A - 32.0A -
DIMENSIONS (MM) 4.75 6.35 Control voltage: 13.6V - 13.8V Discharge current
Trickle use 3.20A 8.00A 16.0A 32.0A 48.0A
Initial current: 2.40A or smaller

6.35

4.5
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

3.2
(187)
(250)
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE

100
100 120
120
+1.5 +1.5 100
100 100 120
120 120
151 98 -0.5 Charging
Charging voltage
voltage 100
-0.5 100

(%)
ratio (%)
2.275V/cell
2.275V/cell
Charging voltage
Charging voltage 100

(years)

(%)
Charging voltage 100 100

life (years)
13.5±0.75

ratio(%)
retention ratio
2.275V/cell 80

Capacity retention ratio (%)


10
10 2.275V/cell
2.275V/cell 80

life (years)
Service (years)

retentionratio
Service life (years)
10 80 5°C
5°C

Capacity retention
10 10 80 80

(7.5)
60

life
60 (41°F)
5°C
(41°F)
5°C

Capacityretention
60 5°C

Service
Servicelife
60 60 (41°F)

+1.5
(41°F)

99 -0.5
1
1 40
40 40°C
40°C 30°C
30°C 25°C
25°C (41°F)

Service

Capacity
11 40
40 40 (104°F)
40°C
(104°F) 30°C
40°C (86°F)
(86°F)
30°C (77°F)
25°C
(77°F)
40°C 30°C 25°C25°C
1 20

Capacity
20 (104°F) (86°F) (77°F)
(104°F)
(104°F) (86°F)
(86°F) (77°F)
20 (77°F)
20 20
0.1 0
0
0.1
Contents indicated (including the recycle marking, etc.) 00 0 2 4 6 8
0.1 0
0 10
10 20
20 30
30 40
40 50
50 60
60 0 2 4 6 8 10 10 12 12 14 14 16
16 18 18 20 20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1 0.1 0
00 22 44 66 Storage 88 10
Storage period
12
period (mth.)
14
(mth.) 16 18 20
00
0
10
10 10 20Temperature
20 30
Temperature
20 30 30
(°C)
40
(°C)40 40
50
50 50 60
60 60 0 2 4 6 8 10 12 14 16 1820 20
10 12 14 16 18
Temperature (°C) Storage
Storage period
period (mth.)
(mth.)
Temperature (°C)(°C)
Temperature Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-PA1216P/P1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V
20
CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY DISCHARGE CURRENT
40°C 120
120
Nominal capacity (20 hour rate) 16Ah 160 Battery
Battery voltage
voltage 16.0
160
140160 16.0
14.016.0 120
120 120
0.3 Battery 0.05CA
0.05CA
Length 151mm 10 140 Batteryvoltage
voltage 14.0 100
100 0.10CA
140 Battery voltage 14.0 0.10CA
0.3 120140 Charge
Charge quantity
quantity (to
(to discharge
discharge quantity)
quantity) 12.014.0 0.05CA

(V)
voltage (V)
Dimensions Width 98mm 0.3 0.3 100 0.05CA
100 100

(CA)
0.05CA
0.10CA

(%)
current (CA)

quantity (%)
120 Charge 12.0 0.10CA
0.25CA
5 Chargequantity
quantity(to(todischarge
dischargequantity) 80 0.25CA

(V)
120 0.10CA
100120 Charge quantity (to discharge quantity) 12.0 10.012.0 80

Battery voltage
quantity)

voltage(V)
0.50CA
(h)

(CA)
Height 105mm 0.50CA

(%)

Battery voltage (V)

(%)
current(CA)
0.2 0.25CA

Capacity (%)
quantity(%)
Charge quantity
80

Charge current
0.25CA

Charge current (CA)


100 10.0

Charge quantity (%)


25°C 11 Discharge 80 80

Batteryvoltage
Approx. mass 4.10kg 3 100
80100 Discharge 10.0
8.0 10.0 0.25CA
0.50CA
0.50CA

(%)
0.2 —
— 100%
100% (0.05CA*20H) 60
60
Duration of discharge

1.00CA

Capacity(%)
Capacity
— 0.50CA

Chargequantity
0.2 0.2 (0.05CA*20H) 1.00CA

Chargecurrent

Capacity (%)
1 Discharge

Battery
Terminal Faston 187/250 80
80
60 80
1—


—Discharge
50%
50%
—100% (0.05CA*10H)
(0.05CA*10H)
1 Discharge
(0.05CA*20H) 8.0
8.0
6.0 8.0 60 2.00CA
2.00CA
1.00CA
60 60

Capacity
— 100%
22—Charge (0.05CA*20H) 1.00CA
Charge
— 3.00CA

Charge
Charge
— 100% (0.05CA*20H)
—(0.05CA*10H) 40 1.00CA
3.00CA

Battery
0.1 — —䚷50%

Charge voltage: 13.7V 40 2.00CA
20 hour rate 16Ah 60 — 50%
Charge (0.05CA*10H)
voltage: 13.7V (2.28V/cell)
(2.28V/cell) 6.0 2.00CA
60 0°C 60
40 60 2 Charge
2䚷 䚷 䚷 — 50%

Charge
Charge
Charge
(0.05CA*10H)
current:
current: 0.15CA
0.15CA 6.0
4.0 6.0 2.00CA
3.00CA
40

Charge
Charge
0.1 2 Charge
Charge voltage: 3.00CA
Capacity 10 hour rate 15Ah 0.1 0.1 40 䚷Charge
33䚷䚷 voltage:13.7V
Temperature:
Temperature:
䚷 䚷Charge 13.7V(77°F)
25°C
25°C
(2.28V/cell)
20.0
(2.28V/cell)
(77°F)20.0 4.0 40 40 3.00CA
40
20 40 Charge current:voltage:
0.15CA
䚷Charge current: 0.15CA 13.7V (2.28V/cell)
4.0
2.0 4.0 20
20
(25°C) 3 hour rate 13Ah 30 䚷Charge current:
Temperature: 25°C 0.15CA
20.0
3 䚷
3 䚷 Temperature: 25°C(77°F)
Charge
Charge 20.0
(77°F)
current
current 20
0 20
200 20 3 䚷Temperature: 25°C 20.0 2.0
(77°F) 2.0
0.0 2.0 20 20
1 hour rate 11Ah Charge 0
0
00 Chargecurrent
current
00 0 4 8 12 16 Charge 20 current
0.0 0.0 24 0.0 00 -15 0 15 30 45
0
(min.)

Fully charged battery 0 -15 0 15 30 45


Impedance 13mΩ 00 4 8Charge12 0
10 -15°C Charge time16
time (h) 20
(h) 24 00 Battery temperature (°C)
(25°C) 0 4 4 8 8 12 12 16 16 20 20 24 24 -15
-15 -15
Battery 15
0 15 15
30
temperature (°C)
30 30
45
45 45
Charge
Chargetime (h)
timetime
(h) (h) Battery temperature (°C)
40°C 102% Charge Battery temperature
Battery (°C)(°C)
temperature
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 1
Self-discharge 0.1 0.3 1 3 10 30 100
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 15.0
15.0
15.0

(V)
voltage (V)
15.015.0

(V)
Terminal voltage
WATT TABLE (25°C) (Wattage/battery)

voltage(V)
Terminal voltage (V)
10.0
10.0 0.8A

Terminalvoltage
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 4.0A
4.0A 0.8A
10.0
10.010.0 16.0A
16.0A 0.8A
48.0A
48.0A 4.0A 0.8A0.8A

Terminal
9.6V 850 716 445 339 277 201 151 124 91.9 73.1 52.8 41.2 34.5 29.7 19.0 10.2 4.0A4.0A
16.0A
16.0A
48.0A
48.0A 16.0A

Terminal
9.9V 815 685 427 323 268 197 150 121 90.1 72.5 52.6 40.9 34.2 29.1 18.9 10.2 48.0A
5.0
5.0
10.2V 760 640 417 307 260 193 144 117 85.4 68.5 50.3 40.1 32.8 28.4 18.1 9.81 5.0
5.0 5.0
10.5V 680 580 398 293 249 185 140 115 82.0 66.4 49.3 39.3 32.7 28.1 18.0 9.78
10.8V 590 520 350 281 238 178 131 106 76.5 59.2 45.7 36.3 29.9 26.0 16.8 9.16 0.0
0.0
0
0 1
1 2
2 4
4 6
6 8
8 10
10 20
20 40
40 60
60 2
2 4
4 6
6 8
8 10
10 20
20 40
40
0.0
0.0 00.0
0 0 11 22 44 66 (min.)
88 10
(min.) 10 20
20 20 40 60
40 40 60 60 22 2 44 66 (h)
88 10
(h) 20 40
AMPERE TABLE (25°C) (Ampere/battery) 1 2 4 6 8 10 4 6 10 8 10 20 20 40 40
(min.)
(min.) (h)
(h) (h)
(min.) Duration
Duration of
of discharge
discharge
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Duration
Durationofofdischarge
discharge
9.6V 82.9 66.3 44.7 32.7 26.3 19.1 13.8 10.9 7.98 6.21 4.33 3.28 2.82 2.34 1.54 0.800 Duration of discharge
9.9V 76.5 62.2 43.8 32.5 25.9 18.9 13.7 10.8 7.82 6.17 4.31 3.26 2.79 2.33 1.53 0.800
10.2V 70.3 58.3 42.7 31.8 25.4 18.7 13.6 10.7 7.66 6.01 4.26 3.24 2.77 2.32 1.52 0.800
10.5V 62.3 52.2 39.5 29.6 24.2 18.3 13.4 10.5 7.50 5.80 4.20 3.22 2.75 2.31 1.51 0.800
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 52.4 45.8 35.3 27.6 23.5 17.6 13.2 10.3 7.29 5.52 4.11 3.18 2.68 2.28 1.49 0.800 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

78 79
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-XD1217P*1 FOR STANDBY POWER SUPPLIES. LC-XD1217P*1


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS
AT 20°C ACCORDING TO EUROBAT. G104101
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
0.850A - 3.40A - 8.50A - 17.0A - 34.0A -
DIMENSIONS (MM) Terminal type (option) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 3.40A 8.50A 17.0A 34.0A 51.0A
Initial current: 2.55A or smaller
11 M5 M5 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

11.8
12.5
(L) (A) INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
181±2 76±2 100 120

1.7
112.7
100100
100 Charging voltage 120120
100120

(%) (%)
2.275V/cell

life (years)
Charging voltage
Charging
Chargingvoltage
voltage

ratioratio
100100

(%)
ratio (%)
10 2.275V/cell 80100

life (years)
2.275V/cell
2.275V/cell

(years)
11.8

life (years)
5°C

retention
retention ratio
10 10 80 80
10 60 80

167±2
(41°F)
5°C

Service

retention
5°C
5°C

Capacity retention
Service life
60 60 (41°F)
40 60 40°C 30°C (41°F)

Service
1 25°C (41°F)

Service

Capacity
(104°F)
40°C (86°F)
30°C (77°F)
1 1 40 40 40°C
40°C 30°C
30°C 25°C
25°C
20 40 25°C

Capacity
1

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
(179.5) (74.5) (104°F) (86°F) (77°F)
20 20
0.1 0 20
Contents indicated (including the recycle marking, etc.)
0
0.10.1 10 20 30 40 50 60 0 00 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: standard (UL94 HB) 0.1
0 0 10 10 Temperature
20 20 30 30 (°C)40 40 50 50 60 60 0 0 2 2 4 4 Storage
6 8 period
10 (mth.)
12 14 14 16 16 18 18 20 20
0 10 20 30 40 50 60 0 2 4 66 88 10 10 1212 14 16 18 20
Temperature (°C) Storage period
Storage (mth.)
Temperature
Temperature(°C)
(°C) Storageperiod
period(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT
Name LC-XD1217PG/APG*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY DISCHARGE CURRENT
20 120
Nominal capacity (20 hour rate) 17Ah 40°C Battery voltage
160
140
160
160 16.0
14.0
16.0
16.0 120120 0.05CA
Length 181mm 10 0.3 Battery voltage
Battery voltage
100120 0.10CA
140
120 Charge quantity (toBattery voltage 14.0
12.0

(CA)(CA)

(%) (%)
140
140 discharge quantity) 14.0
14.0

(V) (V)
Dimensions Width 76mm 0.30.3 0.05CA
0.05CA
0.3 100100 0.05CA
0.10CA
0.25CA
80100 0.10CA

voltage
5 0.10CA

quantity
120 12.0

(%) (%)
100 Charge quantity (to discharge quantity) 10.0

current
120 12.0 0.50CA

(CA)
120 12.0

current (CA)

(%)
Height 167mm Charge
Chargequantity
quantity(to(todischarge
dischargequantity)
(h)

quantity (%)
quantity)

(V)
voltage (V)
25°C 0.2 0.25CA
1 Discharge 80 80 0.25CA

voltage

Capacity
3 0.25CA

quantity
100 10.0

current
Approx. mass 5.900kg 80 8.010.0 60 80 0.50CA

Battery voltage

(%)
100

Charge quantity

Capacity (%)
100 — 100% (0.05CA*20H) 10.0 0.50CA
1.00CA

Charge current
— 0.50CA
Duration of discharge

0.20.2

Battery
0.2 —Discharge

Capacity
1 —
150% (0.05CA*10H) 2.00CA

Charge
Charge
Terminal M5 bolt/nut & threaded post 80
6080 1 Discharge
Discharge 8.0
6.0

Capacity
— 8.0 60 60 1.00CA
80 — 100%
2 Charge
—— (0.05CA*20H)
—100% 8.0
— 100%(0.05CA*20H)
(0.05CA*20H) 40 60 1.00CA
3.00CA
1.00CA

Battery
20 hour rate 17Ah 0.1 —Charge
— 50% voltage: 13.7V (2.28V/cell)
(0.05CA*10H) 2.00CA

Charge
Charge

Battery
———50% 2.00CA
60 60
4060 — 50% (0.05CA*10H)
(0.05CA*10H) 6.0
4.06.0 2.00CA

Charge
Charge
0°C 60 Charge
2 Charge current: 0.15CA 6.0
10 hour rate
2 2 Charge
Charge 40 40 3.00CA
3.00CA
Capacity 16Ah 0.10.1 3 Charge voltage:
Temperature: 13.7V
25°C (2.28V/cell)
(77°F) 3.00CA
0.1 40
2040
Charge
ChargeCharge voltage:
voltage:
current:
13.7V
13.7V(2.28V/cell)
0.15CA (2.28V/cell)4.0
2.04.0 20 40
(25°C) 3 hour rate 14Ah 30 40 Charge current: 0.15CA
Charge current: 0.15CA 4.0
3 Temperature: Charge
25°C current
(77°F)
0 3 3 Temperature:
Temperature:25°C 25°C(77°F)
(77°F) 20 20
1 hour rate 12Ah
20020
20 0.02.0
2.0 2.0 0 20
Charge current
0 00 0 000 4 8 12 16Charge
20current
Charge current
24 0.0
0.0 0 -15 0 15 30 45
(min.)

Impedance
Fully charged battery
12mΩ 10
-15°C 0.0 00
(25°C) 0 00 4 44 Charge time (h)
8 88 12 12 16 16
12 16 20 20
20 24 24
24 -15-15 0Battery temperature
15 15 (°C)
30 30 45 45
-15 00 15 30 45
Charge time (h)(h)
Charge
40°C 102% 5 Chargetime
time (h) Battery temperature
Battery (°C)
Batterytemperature
temperature(°C)
(°C)
Temperature dependency 25°C 100% 3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
0.1 0.3 1 3 10 30 100 20.0
20.0
Self-discharge
After 6 month 82%
(25°C) Discharge current (A)
15.0

(V) (V)
After 12 month 64%

voltage
15.0
15.0
15.0

(V)
voltage (V)
voltage
WATT TABLE (25°C) (Wattage/battery)

Terminal voltage
10.0 0.850A
4.25A

Terminal
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 34.0A 17.0A
10.0
10.0
10.0 51.0A 0.850A
4.25A 0.850A

Terminal
9.6V 1,021 806 526 402 337 251 177 142 97.6 75.5 56.2 43.2 35.6 28.6 19.0 10.3 4.25A
4.25A 0.850A

Terminal
34.0A
34.0A 17.0A
17.0A
51.0A 34.0A 17.0A
9.9V 948 756 516 399 331 249 176 140 95.6 74.9 55.9 42.9 35.4 28.5 18.9 10.3 5.0 51.0A
51.0A
10.2V 874 708 502 391 326 246 175 139 93.7 73.0 55.4 42.6 35.1 28.3 18.7 10.2 5.05.0
5.0
10.5V 777 634 465 364 309 240 172 136 91.7 70.4 54.5 42.3 34.8 28.0 18.6 10.2
10.8V 656 561 415 339 301 232 169 134 89.2 67.1 53.4 41.8 33.9 27.5 18.4 10.1 0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.00.0
0.0 (min.) (h)
0 0 1 1 2 2 3 3 5 5 7 7 10 10 20 20 40 40 60 60 2 2 4 4 6 6 8 810 10 20 20 40 40
AMPERE TABLE (25°C) (Ampere/battery) 0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
(min.)
(min.) Duration of discharge (h)(h)
(min.) (h)
Cut-off 3min. 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Duration of discharge
Duration
9.6V 91.8 72.2 47.0 34.9 29.0 21.5 15.1 12.0 8.26 6.37 4.72 3.61 2.97 2.39 1.58 0.86 Durationofofdischarge
discharge
9.9V 85.2 67.8 46.0 34.7 28.6 21.2 15.0 11.9 8.10 6.33 4.70 3.59 2.95 2.38 1.57 0.85
10.2V 78.6 63.5 44.9 34.0 28.1 21.0 14.9 11.7 7.93 6.16 4.65 3.57 2.93 2.36 1.56 0.85
10.5V 69.9 56.9 41.6 31.6 26.7 20.5 14.6 11.6 7.77 5.95 4.58 3.54 2.90 2.33 1.55 0.85
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 59.0 50.3 37.1 29.5 26.0 19.8 14.4 11.3 7.56 5.67 4.49 3.49 2.83 2.29 1.53 0.85 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

80 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-PD1217PG/APG. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-PD1217PG/APG. 81
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P1220P FOR STANDBY POWER SUPPLIES. LC-P1220P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
1.00A - 4.00A - 10.0A - 20.0A - 40.0A -
DIMENSIONS (MM) Terminal type (option) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 4.00A 10.0A 20.0A 40.0A 60.0A
11 M5 Initial current: 3.00A or smaller
M5 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

11.8
12.5
(L) (A) INFLUENCE OF TEMPERATURE ON TRICKLE LIFE

181±2 76±2 100 120

1.7
112.7 Charging voltage
100 120
100 100120

(%) (%)
2.275V/cell
Charging voltage
Charging voltage 100

ratioratio
2.275V/cell 80100

life (years)
10

Capacity retention ratio (%)


11.8
2.275V/cell
5°C

retention
80

life (years)
10

167±2
60 80

Service life (years)


10 (41°F)
5°C

retention
5°C
60 40°C 30°C 25°C (41°F)

Service
1 40 60 (41°F)

Capacity
(104°F)
40°C (86°F)
30°C (77°F)
25°C

Service
1 40 40°C 30°C 25°C
1 20 40

Capacity
(104°F) (86°F) (77°F)
(179.5) (74.5) (104°F) (86°F) (77°F)
20
0.1 0 20
Contents indicated (including the recycle marking, etc.) 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1 0 10 20 30 40 50 60 0
0
0.1 Temperature (°C) 0 2 4 6 Storage
8 period
10 12 (mth.)
14 16 18 20
0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60 Storage period (mth.)
Temperature (°C) Storage period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)
Name LC-P1220P/AP CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY DISCHARGE CURRENT
20 120
Nominal capacity (20 hour rate) 20Ah 40°C Battery voltage
160
140 16.0
14.0 120
0.3 160 16.0 0.05CA
Length 181mm 10 Battery voltage 100120 0.10CA
140
120 Battery
Charge quantity (to voltage
discharge quantity) 14.0
12.0

(CA) (CA)
140 14.0 0.05CA

(%) (%)
Dimensions Width 76mm 0.3

(V) (V)
0.3 100 100 0.05CA
0.25CA
0.10CA
80100

(%) (%)
5 120 Charge quantity (to discharge quantity) 10.0
12.0 0.10CA
0.50CA

quantity

voltage
Height 167mm

current
25°C 120 12.0
(h)

0.2 Charge quantity (to discharge quantity)

Charge current (CA)

Charge quantity (%)


1 Discharge 0.25CA

Capacity
Battery voltage (V)
Approx. mass 5.80kg 3 100
80 — 10.0
8.0 80 0.25CA
0.50CA

quantity

voltage
60 80

Capacity (%)
— 100% (0.05CA*20H) 1.00CA

current
0.2 100 10.0 0.50CA
Duration of discharge

—Discharge

Capacity
0.2 60 1— 50% (0.05CA*10H) 2.00CA

Battery
Terminal M5 bolt/nut & threaded post 80 Discharge 6.0
8.0

Charge
Charge
2— 1100%
—Charge (0.05CA*20H) 60 1.00CA
80 —
— 100% (0.05CA*20H) 8.0 40 60 3.00CA
1.00CA
20 hour rate 20Ah 0°C 0.1 —Charge
— 50% voltage: 13.7V (2.28V/cell)
(0.05CA*10H) 2.00CA

Battery
40
60 — 50%
— 4.0
6.0

Charge
2.00CA

Charge
60 2 Charge
Charge (0.05CA*10H)
current: 0.15CA
60 2 Charge 6.0 40 3.00CA
Capacity 10 hour rate 17Ah 0.1 3 Temperature:
Charge voltage:25°C
13.7V(77°F)
(2.28V/cell)
20 40 3.00CA
0.1 20
40 Charge
Charge voltage:
current: 13.7V (2.28V/cell) 2.0
0.15CA 4.0
(25°C) 3 hour rate 15Ah 30 40 Charge current:
3 Temperature: Charge 0.15CA
current
25°C (77°F) 4.0
0 200 3 Temperature: 25°C (77°F)
0.0
2.0 20
1 hour rate 12Ah 20 Charge current 2.0 0 20
Fully charged battery
-15°C 0
0 0 0 4 8 12 16Charge 20current24 0.0
0 -15 0 15 30 45
(min.)

Impedance 15mΩ 0 Charge time (h) 0.0 0


(25°C) 10 0 4 8 12 16 20 24 Battery temperature (°C)
0 4 8 12 16 20 24 -15 0 15 30 45
Charge time (h) -15 0 15 30 45
40°C 102% Charge time (h) Battery temperature (°C)
5 Battery temperature (°C)
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
Self-discharge 0.1 0.3 1 3 10 30 100 20.0
After 6 month 82%
(25°C) Discharge current (A) 15.0
After 12 month 64%

(V) (V)
15.0

voltage
15.0

Terminal voltage (V)


WATT TABLE (25°C) (Wattage/battery)

voltage
10.0
5.00A 1.80A 1.00A
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h

Terminal
10.0 60.0A 20.0A
9.6V 853 557 425 357 266 188 150 103 83.1 61.9 47.5 39.2 31.5 21.6 11.7 10.0 5.00A 1.80A 1.00A
5.00A 1.80A 1.00A

Terminal
60.0A 20.0A
9.9V 800 546 423 351 263 186 148 101 82.5 61.5 47.2 38.9 31.4 21.5 11.7 5.0 60.0A 20.0A
10.2V 750 532 414 345 260 185 146 99.1 80.3 60.9 46.9 38.6 31.2 21.3 11.6
5.0
5.0
10.5V 672 493 385 328 254 182 145 97.0 77.5 60.0 46.6 38.3 30.8 21.2 11.6
10.8V 594 440 359 319 246 179 141 94.3 73.9 58.8 46.0 37.4 30.3 21.0 11.5 0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.0
0.0 (min.) (h)
AMPERE TABLE (25°C) (Ampere/battery) 0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
(min.) Duration of discharge (h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h (min.) (h)
9.6V 85.0 55.3 40.0 34.2 24.0 16.9 12.7 9.04 6.98 5.17 3.95 3.26 2.61 1.75 1.01 Duration of discharge
Duration of discharge
9.9V 79.7 54.2 39.7 33.6 23.7 16.8 12.6 8.86 6.92 5.14 3.93 3.23 2.60 1.75 1.01
10.2V 74.7 52.8 38.9 33.1 23.5 16.6 12.4 8.68 6.74 5.09 3.90 3.20 2.58 1.73 1.00
10.5V 66.9 48.9 36.2 31.4 22.9 16.4 12.2 8.50 6.51 5.01 3.88 3.18 2.55 1.72 1.00
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 59.2 43.6 33.8 30.6 22.2 16.1 12.0 8.27 6.20 4.91 3.82 3.10 2.51 1.70 0.994 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

82 83
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P1224P FOR STANDBY POWER SUPPLIES. LC-P1224P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS
AT 20°C ACCORDING TO EUROBAT. G198049
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
1.2A - 4.8A - 12A - 24A - 48A -
DIMENSIONS (MM) Terminal type (option) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 4.8A 12A 24A 48A 72A
Initial current: 3.6A or smaller
16 M5 M5 Cut-off voltage (V) 10.5 10.2 9.9 9.3 8.7

9.8
16.5
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE RESIDUAL CAPACITY VS. STORAGE PERIOD
(L) (A) 100
100 120
120
100
100 120 120
165±2 125±2 11 Chargingvoltage
Charging voltage
(134) 1 Charging voltage
2.275V/cell
Charging
1 2.275V/cell voltage 100
100
(8) (16) (12) 100 100

(%)
2.275V/cell

(%)(%)
(90) 2.275V/cell 120

Capacity retention ratio (%)


100
80
80

ratio
䚷䚷

ratio
10 80
1010

Charging voltage
1
80 5°C

ratio
䚷 100 5°C
10

(years)
2.275V/cell 5°C

(years)

retention
retention
(16.5)
60

Service life (years)


5°C
(41°F)

Capacity retention ratio (%)


60 (41°F)

(12)
60

(years)
(41°F)

retention
䚷 80 60 (41°F)
10 40°C 30°C 25°C
40°C 30°C

life
25°C

(179.5)
40 5°C

lifelife
40°C 30°C

175±2
40 40 25°C

Service life (years)


60 40°C
(104°F)
(104°F) 30°C
(86°F)
(41°F)
(86°F) 25°C
(77°F)

Capacity
1 11 40 (104°F) (86°F) (77°F)

Capacity
(77°F)

Service
Service
(104°F) (86°F) (77°F)

Capacity
1

Service
20 20
2040°C 30°C 25°C
40
1 20(104°F) (86°F) (77°F)
(163.4) (124)
20 0 00
Contents indicated (including the recycle marking, etc.) 0 0 2 00 4 22 6 44 8 6610 8812 10 10
14 12 12
16 1414 16
18 16 18
20 18 2020
0.1
0.10.1
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0 0 2 Storage
4 6period8 (mth.)
Storage 10 12
period 14 16 18 20
(mth.)
0.10 00 10 10
10 20 20
20 30 3030 40 40
40 50 50 60
50 60
60 0 2 4 6 8 10
Storage
12
period
14 Storage
(mth.)
16 18period
20 (mth.)
0.1 0 10 Temperature
20 30 (°C)40
Temperature
Temperature (°C)
(°C) 50 60
0 10 20 30 40 50 60 Storage period (mth.)
Temperature (°C)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)
Name LC-P1224PG/APG CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS FOR TRICKLE USE AND BY DISCHARGE CURRENT
20
Nominal capacity (20 hour rate) 24Ah 160 16
16
16 160
160 Battery voltage 120
Length 165mm 10 160 140
160 16 Battery voltage16
Batteryvoltage
14 120
120
0.3 140
140 14
14
Battery voltage
Battery voltage
120
120 0.05CA
40°C 0.3
Dimensions Width 125mm 0.3 0.3140 Charge quantity (to discharge quantity) 14 100 0.10CA 0.05CA
0.05CA
5 120140 Chargequantity
quantity(to(todischarge quantity)12
dischargequantity) 14 100
100 0.05CA 0.10CA
0.3 Charge

Charge current (CA)


100 0.10CA

Charge quantity (%)


Height 179.5mm/175mm 120
120 Charge quantity (to discharge quantity) 12
12 0.10CA 0.05CA

Battery voltage (V)


120 Charge quantity (to discharge12
(h)

0.25CA

(CA)
100

(%)
quantity)

(CA)
80 0.10CA

Charge current (CA)

(%)(%)
100120 10 12

Charge quantity (%)

(V)
0.50CA

(V)(V)
3 25°C 0.25CA

Battery voltage (V)

Capacity (%)
Approx. mass 8.05kg 80 0.25CA 0.25CA

(CA)
0.2 100 100 100 10 10
10 80 80 0.50CA

quantity
0.50CA

(%)
0.50CA

voltage
Duration of discharge

Capacity (%)
quantity
current
1 Discharge

(%)(%)
0.25CA

voltage
current
Terminal M5 bolt/nut & threaded post 0.2 0.2 0.2 80100 1 Discharge 100% (0.05CA*20H) 8 10 60 80 1.00CA
Discharge 0.50CA

quantity
1

voltage
Discharge

current
8
0.2 80
1
80 88

Capacity
80 60

Capacity
100% (0.05CA*20H)
50% (0.05CA*10H)
100%(0.05CA*20H)
(0.05CA*20H) 60
60 1.00CA 2.00CA 1.00CA
20 hour rate 24Ah 60 80 Charge
50% 2(0.05CA*10H)
100%
1 Discharge 6 2.00CA 1.00CA
8

Capacity
60 60 50%(0.05CA*10H)
50% (0.05CA*10H) 6 40 60 3.00CA 2.00CA
2.00CA
1.00CA

Battery
2 Charge Charge100% (0.05CA*20H)
voltage: 13.65V (2.275V/cell)

Charge
Charge

Battery
60 66 3.00CA

Charge
Charge
Capacity 10 hour rate 22Ah 0.1 40
60 Charge voltage:
Charge Charge
22 Charge
13.65V
50% (2.275V/cell)
current: 0.15CA
(0.05CA*10H) 4
40 3.00CA
2.00CA
3.00CA
0.1 40

Battery
0°C Charge
0.15CA voltage:13.65V
13.65V (2.275V/cell) 40

Charge
Charge
60 25°C (77°F) 4 (2.275V/cell) 6
Charge current:Charge
(25°C) 3 hour rate 18Ah 30 0.140
0.1 2 Charge voltage:
3 Temperature:
Charge current:0.15CA
0.15CA 20 3.00CA
40 Charge voltage: 13.65V (2.275V/cell) 44
3 Temperature: 25°C 40
Charge(77°F)
current:
40 (77°F) 2
20
0.1 20 20 40 Temperature:
33 Charge
Temperature:
current:
Charge
25°C
25°C 2(77°F)
0.15CA
current 4 20
1 hour rate 14Ah Charge current 20
0 0
20
20 3 Temperature: 25°C (77°F)
0 current 0 22 0 0 20
Fully charged battery 0 0 20
Charge
Charge current
2
(min.)

Impedance 11mΩ -15°C 0 04 48 812 12


16 16
20 20 -15 -15
0 00 150 30 15 45 30 45
(25°C) 10
00 00 ChargeCharge
time (h)time (h)
Charge current 00 Battery Battery(°C)
temperature temperature (°C)
0 00 44 88 12
12 16
16 20
20 0 0 -15
-15 00 15
15 30
30 45
45
40°C 102% 0
5 0 4 8
Charge
Charge 12
time(h)
time (h)16 20 -15 Batterytemperature
0 Battery temperature
15 30(°C)
(°C) 45
Temperature dependency 25°C 100% Charge time (h) Battery temperature (°C)
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
After 3 month 91% 1 15
15
Self-discharge 0.3 1 3 10 30 100
After 6 month 82% 14
(25°C) Discharge current (A)
After 12 month 64% 15
1415
13 15
1314
14
(Wattage/battery) 12
WATT TABLE (25°C) 14
12 13

Terminal voltage (V)


Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 11 13
13

Terminal voltage (V)


9.6V 992 739 523 441 317 234 183 118 104 73.8 58.6 47.9 40.8 26.4 14.6 11 12 1.2A
10 12 2.4A
6.0A
9.9V 931 724 520 434 314 232 181 116 103 73.4 58.2 47.5 40.6 26.3 14.6 12 1.2A
9 1011

(V)
2.4A

(V)(V)
11 24.0A 12.0A
10.2V 872 706 509 426 310 230 179 113 101 72.7 57.8 47.2 40.3 26.0 14.5 6.0A

voltage
voltage
11 72.0A 24.0A 12.0A
10.5V 8 9 1.2A
voltage
782 654 474 405 303 226 175 111 97.2 71.6 57.4 46.8 39.8 25.9 14.4 10
10 2.4A 1.2A
6.0A 2.4A
72.0A 6.0A 1.2A
10.8V 691 583 442 394 293 223 172 108 92.6 70.1 56.6 45.6 39.2 25.6 14.3 7 810 2.4A
Terminal
6.0A
Terminal

99 24.0A
24.0A 12.0A
12.0A
Terminal

6 7 9 24.0A 12.0A
AMPERE TABLE (25°C) (Ampere/battery) 72.0A
72.0A
88
5 6
8 72.0A
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
77
9.6V 89.0 66.0 45.5 38.0 27.1 19.9 14.6 10.0 8.80 6.20 4.90 3.89 3.40 2.27 1.23 5 7 (min.) (h)
9.9V 83.5 64.7 45.2 37.4 26.8 19.8 14.5 9.80 8.73 6.17 4.87 3.86 3.39 2.26 1.22 066 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
Duration of discharge
10.2V 78.2 63.0 44.3 36.8 26.5 19.6 14.3 9.60 8.51 6.11 4.84 3.83 3.36 2.23 1.21 6 (min.) (h)
55
10.5V 70.1 58.4 41.2 34.9 25.9 19.3 14.0 9.40 8.21 6.01 4.80 3.80 3.32 2.22 1.20
0 11 are for22descriptive44purposes
5 0document
The data in this 66 88only10and are 20
10 20 intended
Duration
not 40
of40 60 or imply
60
discharge
to make 22 any guarantee
44 66 or8warranty.
8 10 10 20
20
Regarding 40 and safety
40
handling
10.8V 62.0 52.1 38.4 34.0 25.0 19.0 13.7 9.14 7.82 5.89 4.74 3.71 3.27 2.20 1.19 0 VRLA
please consult our 1 technical
2 handbook4chapter 6 1.8 10 20 40 60 2 4 6 8 (h)10 20 40
(min.)
(min.) (h)
All mentioned values are average values (min.) (h)
Duration of discharge
Duration of discharge
Duration of discharge
84 85
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P1228P FOR STANDBY POWER SUPPLIES. LC-P1228P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
1.40A - 5.60A - 14.0A - 28.0A - 56.0A -
DIMENSIONS (MM) Terminal type (option) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 5.60A 14.0A 28.0A 56.0A 84.0A
Initial current: 4.20A or smaller
16 M5 M5 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

9.8
16.5
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L) (A)

165±2 125±2 100 120


(134)
(8) (16) (12) 100
100 Charging voltage 120
(90) 120
100
2.275V/cell

(%) (%)
Charging
Chargingvoltage
voltage
100

ratio ratio
10 100
80

life (years)
2.275V/cell
2.275V/cell

Capacity retention ratio (%)


(16.5)
5°C

(12)

retention
1010 8080

life (years)
Service life (years)
60 (41°F)
5°C
5°C

(179.5)
175±2

retention
60
4060

Service
1 40°C 30°C 25°C (41°F)
(41°F)

Capacity
(104°F) (86°F) (77°F)

Service
11 4040
20 40°C
40°C 30°C
30°C 25°C
25°C

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
(163.4) (124)
20020
0.1
Contents indicated (including the recycle marking, etc.) 0 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1
0.1 00
Temperature (°C) 00 22 44 6Storage period (mth.)
00 1010 2020 3030 4040 5050 6060 6 8 8 1010 1212 1414 1616 1818 2020
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature
Temperature(°C)
(°C) Storage
Storageperiod
period(mth.)
(mth.)
Name LC-P1228P/AP CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY
120
DISCHARGE CURRENT
20 40°C Battery voltage
Nominal capacity (20 hour rate) 28Ah 140 14.0
160
160 16.0
16.0 120 0.05CA
Length 165mm 10 0.3 Battery voltage 120
100 0.10CA
120 Charge quantity Battery voltage
(to discharge quantity) 12.0

(CA) (CA)

(%) (%)
140
140 14.0
14.0

(V) (V)
Dimensions Width 125mm 0.3 0.05CA
0.05CA
0.3 100
100
80 0.25CA

quantity
5 100 10.0 0.10CA
0.10CA

voltage
current
Charge quantity (to(to
discharge quantity)

(%) (%)
120
120 Charge quantity discharge quantity) 12.0
12.0 0.50CA

Charge current (CA)

Charge quantity (%)


Height 175mm/179.5mm
(h)

25°C 0.2

Battery voltage (V)


1 Discharge 0.25CA

Capacity
3 80 8.0 8080 0.25CA

quantity
Approx. mass 9.40kg 100 — 10.0 60

voltage
current
100 — 100% (0.05CA*20H) 10.0 0.50CA
1.00CA

Capacity (%)
0.50CA
Duration of discharge

0.2
0.2 1—

50% (0.05CA*10H)

Charge

Battery
2.00CA

Charge
Terminal M5 bolt/nut & threaded post 60 1Discharge
Discharge 6.0

Capacity
8080 —Charge
2——100% (0.05CA*20H)
— 100% (0.05CA*20H)
8.0
8.0 6060 3.00CA
1.00CA
20 hour rate 28Ah 0.1 —Charge

voltage: 13.7V (2.28V/cell) 40 1.00CA
— 50% (0.05CA*10H)

Charge

Battery
40 4.0 2.00CA

Charge
0°C — 50%
Charge (0.05CA*10H)
current: 0.15CA 2.00CA
60 6060 2 2Charge
Charge 6.0
6.0
3 Temperature: 3.00CA
Capacity 10 hour rate 26Ah 0.1
0.1 Charge voltage:25°C
13.7V(77°F)
(2.28V/cell)
Charge voltage: 13.7V (2.28V/cell) 4040
20
3.00CA
20
4040 Charge
Chargecurrent: 0.15CA
current: 0.15CA 2.0
4.0
4.0
(25°C) 3 hour rate 22Ah 30 Charge current
0 3 3Temperature:
Temperature:25°C (77°F)
25°C (77°F)
1 hour rate 21Ah 20020 0.0
2.0
2.0
20020
0 4 8 12 Charge
16
Chargecurrent
20
current24
-15°C 00 00 0.0 -15 0 15 30 45
Fully charged battery 0.0
(min.)

Impedance 11mΩ Charge time (h) 00 Battery temperature (°C)


(25°C) 10 00 44 88 1212 1616 2020 2424 -15
-15 00 1515 3030 4545
40°C 102% Charge
Chargetime
time(h)
(h) Battery
Batterytemperature
temperature(°C)
(°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
20.0
Self-discharge 1 3 10 30 100 300 1,000
After 6 month 82%
(25°C) Discharge current (A) 15.0
After 12 month 64%

(V) (V)
voltage
15.0
15.0

Terminal voltage (V)


WATT TABLE (25°C) (Wattage/battery)

voltage
10.0 1.4A
7.0A

Terminal
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 56.0A
10.0
10.0
84.0A 1.4A
9.6V 1,160 865 664 585 410 304 260 159 129 91.6 74.1 61.1 50.8 31.8 16.8 7.0A
7.0A 1.4A

Terminal
56.0A
56.0A
5.0 84.0A
84.0A
9.9V 1,093 849 654 579 404 294 254 156 128 90.4 72.9 60.8 50.4 31.8 16.8
10.2V 1,026 818 643 567 397 288 251 155 127 89.3 71.7 60.5 49.9 31.8 16.8 5.0
5.0
10.5V 976 784 621 545 386 282 247 154 126 88.1 71.1 60.2 49.5 31.8 16.8
0.0
10.8V 903 773 610 539 374 255 218 149 118 84.5 70.5 59.9 49.0 31.8 16.8
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.0
0.0 (min.) (h)
(Ampere/battery) 00 11 22 33 55 77 1010 2020 4040 6060 22 44 6 6 8 8 1010 2020 4040
AMPERE TABLE (25°C) (min.) Duration of discharge (h)
(min.) (h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Duration
Durationofofdischarge
discharge
9.6V 104 77.2 57.7 50.4 35.0 25.9 22.1 13.5 10.9 7.70 6.20 5.10 4.30 2.60 1.40
9.9V 98.0 75.8 56.9 49.9 34.5 25.0 21.6 13.2 10.8 7.60 6.10 5.06 4.28 2.60 1.40
10.2V 92.0 73.0 55.9 48.9 33.9 24.5 21.3 13.1 10.7 7.50 6.00 5.03 4.25 2.60 1.40
10.5V 87.5 70.0 54.0 47.0 33.0 24.0 21.0 13.0 10.6 7.40 5.95 4.99 4.23 2.60 1.40
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 81.0 69.0 53.0 46.5 32.0 21.7 18.5 12.6 10.0 7.10 5.90 4.95 4.20 2.60 1.40 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

86 87
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P1238P FOR STANDBY POWER SUPPLIES. LC-P1238P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS
AT 20°C ACCORDING TO EUROBAT. G100002
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
1.90A - 7.60A - 19.0A - 38.0A - 76.0A -
DIMENSIONS (MM) Terminal type (option) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 7.60A 19.0A 38.0A 76.0A 114A
16 M6
Initial current: 5.70A or smaller
M5 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

16.5

9.8
(61)
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L) (A)

100 120
197±2 165±2
100
100
100 Charging voltage 120
120
(155) 100
120

ratio (%)
(111) (27.5) 2.275V/cell
Charging
Charging
Charging voltage
voltage
voltage 100

(%)
10 100
80
100

ratio (%)
life (years)
2.275V/cell

ratio(%)
2.275V/cell
2.275V/cell

(8.3)

(1.7)
(9.8)
5°C

retention
retentionratio
80

175±2 (11.5)
10

(years)
1010 80
6080

life (years)
(41°F)

life(years)
5°C
5°C
5°C

retention
Capacityretention
6060
4060 40°C 30°C (41°F)
25°C

Service
1 (41°F)
(41°F)

Capacity
Servicelife
(104°F) (86°F) (77°F)
40 40°C 30°C 25°C
1 11 40
2040 40°C
40°C 30°C
30°C 25°C
25°C

Service
Service

Capacity
(104°F) (86°F)

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
(77°F)
(195.2) (164) 20
20020
0.1
Contents indicated (including the recycle marking, etc.) 0 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1
0.10.1 0 00
Storage period (mth.)
0 00 10
1010
Temperature
20
2020 30 (°C)
3030 40
4040 50
5050 60
6060 0 00 2 22 4 44 6 66 8 88 1010
10 1212
12 1414
14 1616
16 1818
18 2020
20
Storage
Storage period
period
Storage (mth.)
(mth.)
period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature
Temperature (°C)
(°C)
Temperature (°C)
Name LC-P1238PG/APG CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY
120DISCHARGE CURRENT
20
Battery voltage
Nominal capacity (20 hour rate) 38Ah 140 14.0
40°C 160
160
160 16.0
16.0
16.0 120 0.05CA
Length 197mm 10 0.3 Battery voltage 120
120
100 0.10CA
Battery voltage
Battery voltage
120
140 Charge quantity (to discharge quantity) 12.0
14.0

(CA) (CA)

(%) (%)
0.3 140
140 14.0
14.0 0.05CA

(V) (V)
Dimensions Width 165mm 0.3 100 0.05CA
0.05CA
0.25CA
0.3 100
100
80 0.10CA
0.10CA

quantity
5 100
120 Charge quantity (to discharge quantity) 10.0
12.0 0.10CA
0.50CA

(CA)
current

(%)

(%) (%)
voltage
Height 175mm/180mm 120
120 Charge
Chargequantity (to(to
quantity discharge
discharge quantity)
quantity) 12.0
12.0
(h)

current(CA)

quantity(%)
0.2

(V)
1 Discharge 0.25CA

voltage(V)
3 80 8.0 80 0.25CA
0.25CA

Capacity
Approx. mass 12.5kg 25°C 100 — 10.0 80
6080 0.50CA

quantity

(%)
100 — 100% (0.05CA*20H) 10.0 1.00CA

Chargequantity
100 10.0 0.50CA
0.50CA

current

voltage
Chargecurrent

Capacity(%)
Batteryvoltage
Duration of discharge

0.20.2
0.2 —1 50%
— (0.05CA*10H)
Discharge 2.00CA

Charge

Battery
Charge
Terminal M6 bolt/nut & M5 threaded post 6080 1 1Discharge
—Discharge
2—Charge 6.0
8.0
8080 8.0 60

Capacity
— 100% (0.05CA*20H) 8.0 1.00CA

Capacity
—— 60 3.00CA
1.00CA
20 hour rate 38Ah 0.1 100% (0.05CA*20H)

— 100%
Charge
— 50%
(0.05CA*20H)
voltage: 13.7V (2.28V/cell)
(0.05CA*10H)
4060 1.00CA
2.00CA
4060 —Charge
— 4.0 2.00CA
60 — 50%
— 50%(0.05CA*10H)
(0.05CA*10H)
current: 0.15CA 6.0 2.00CA

Charge

Battery
Charge
Charge

Battery
60 6.0

Charge
60 2 Charge
23 2Charge
Charge 6.0 3.00CA
Capacity 10 hour rate 36Ah 0°C 0.1 Temperature:
Charge 25°C13.7V
voltage: (77°F)
(2.28V/cell) 4040 3.00CA
3.00CA
0.10.1 2040 Charge
Charge
Charge
voltage: 13.7V
voltage:
current: 13.7V(2.28V/cell)
0.15CA(2.28V/cell) 2.0
4.0 2040
(25°C) 3 hour rate 29Ah 30 40 40 Charge
Chargecurrent: 0.15CA
current: 0.15CA 4.0
4.0
3 Temperature: Charge
25°C current
(77°F)
0 3 3Temperature:
Temperature: 25°C (77°F)
25°C (77°F) 20
1 hour rate 23Ah 20020
20 0.0
2.0
2.0
2.0 20020
0 4 8 12 16 Charge
20 current
24
0 00
Charge current
Charge current -15 0 15 30 45
Fully charged battery 0 00 0.0
0.0
0.0 0 00
(min.)

Impedance 10mΩ Charge time


(25°C) 10 -15°C 0 00 4 44 888 12 (h)
16 20 2424
1212 1616 2020 24 -15
Battery temperature (°C)
-15-15 0 00 15
1515 30
3030 45
4545
40°C 102% Charge
Charge
Charge time
time (h)
(h)(h)
time Battery
Battery temperature
temperature (°C)
(°C)
5 Battery temperature (°C)
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
20.0
20.0
Self-discharge 1 3 10 30 100 300 1,000
After 6 month 82%
(25°C) Discharge current (A) 15.0
After 12 month 64%

(V) (V)
15.0

voltage
15.0
15.0

(V)
voltage(V)
WATT TABLE (25°C) (Wattage/battery)

voltage
10.0

Terminalvoltage
9.5A 3.8A 1.9A

Terminal
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 38.0A
10.0
10.0
114.0A 3.8A 1.9A
9.6V 1,349 1,030 800 686 505 351 276 214 169 123 99.2 77.9 68.3 42.0 22.8 10.0 9.5A
9.5A
9.5A 3.8A
3.8A 1.9A
1.9A
38.0A
Terminal
Terminal
114.0A 38.0A
38.0A
9.9V 1,271 1,008 788 682 500 350 269 209 168 120 98.0 76.7 68.0 42.0 22.8 5.0 114.0A
114.0A
10.2V 1,204 980 768 672 489 349 267 185 167 119 96.8 75.5 67.7 42.0 22.8
5.0
5.05.0
10.5V 1,126 952 748 661 480 346 265 183 166 117 95.6 74.9 67.4 42.0 22.8
10.8V 1,098 874 716 640 468 308 247 175 155 114 94.4 74.3 67.1 42.0 22.8 0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.0
0.00.0 (min.) (h)
AMPERE TABLE (25°C) (Ampere/battery) 0 00 1 11 2 22 3 33 5 55 7 77 101010 20
2020 40 6060
4040 60 2 22 4 44 6 66 8 88 1010
10 20
2020 40
4040
(min.)
(min.)
(min.) Duration of discharge (h)
(h)(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
9.6V 121 92.0 69.6 59.1 43.2 29.9 23.4 18.1 14.3 10.3 8.30 6.50 5.70 3.60 1.90 Duration
Duration
Duration of
ofof discharge
discharge
discharge
9.9V 114 90.0 68.5 58.8 42.7 29.8 22.8 17.7 14.2 10.1 8.20 6.40 5.68 3.60 1.90
10.2V 108 87.5 66.8 57.9 41.8 29.7 22.7 15.7 14.1 10.0 8.10 6.30 5.66 3.60 1.90
10.5V 101 85.0 65.0 57.0 41.0 29.5 22.5 15.5 14.0 9.80 8.00 6.25 5.64 3.60 1.90
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 98.5 78.0 62.3 55.2 40.0 26.2 21.0 14.8 13.1 9.60 7.90 6.20 5.60 3.60 1.90 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

88 89
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P1242P FOR STANDBY POWER SUPPLIES. LC-P1242P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
2.10A - 8.40A - 21.0A - 42.0A - 84.0A -
DIMENSIONS (MM) Terminal type (option) Control voltage: 13.6V - 13.8V Discharge current
Trickle use 8.40A 21.0A 42.0A 84.0A 126A
16 M6
Initial current: 6.30A or smaller
M5 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

16.5

9.8
(61)
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L) (A)

100 120
197±2 165±2
100
100
100 Charging voltage 120
120
(155) 100
120

ratio (%)
(111) (27.5) 2.275V/cell
Charging
Charging
Charging voltage
voltage
voltage 100

(%)
10 100
80
100

ratio (%)
life (years)

ratio(%)
2.275V/cell
2.275V/cell
2.275V/cell 5°C

(8.3)

(1.7)
(9.8)

retention
80

retentionratio
175±2 (11.5)
10

(years)
1010 80
6080 (41°F)

life (years)
life(years)
5°C
5°C
5°C

retention
Capacityretention
6060
4060 40°C 30°C 25°C (41°F)
(41°F)
(41°F)

Service
1

Capacity
Servicelife
(104°F) (86°F) (77°F)
40 40°C 30°C 25°C
1 11 40
2040 40°C
40°C 30°C
30°C 25°C
25°C

Service
Service
(104°F) (86°F) (77°F)

Capacity
Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
(195.2) (164) 20
20020
0.1
Contents indicated (including the recycle marking, etc.) 0 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.1
0.10.1 0 00
Storage period (mth.)
0 00 10
1010
Temperature
20
2020 30 (°C)4040
3030 40 50
5050 60
6060 0 00 2 22 4 44 6 66 8 88 1010
10 1212 1414
12 14 1616
16 1818
18 2020
20
Storage
Storage
Storage period
period
period (mth.)
(mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature
Temperature (°C)
(°C)
Temperature (°C)
Name LC-P1242P/AP CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY
120 DISCHARGE CURRENT
20
Nominal capacity (20 hour rate) 42Ah 40°C Battery voltage
140
160 14.0
16.0
0.3 160
160 16.0
16.0 120
120
120
100
0.05CA
Length 197mm 10 Battery
Battery voltage
voltage
Battery voltage
0.10CA
120
140 Charge quantity (to discharge quantity) 12.0
14.0

(CA) (CA)

(%) (%)
0.3 140
140 14.0
14.0 0.05CA

(V) (V)
Dimensions Width 165mm 0.3 100 0.05CA
0.05CA
0.25CA
5 0.3 100
100
80 0.10CA
0.10CA

quantity
100
120 Charge quantity (to discharge quantity) 10.0
12.0 0.10CA
0.50CA

(CA)
current

(%)

(%) (%)
voltage
Height 175mm/180mm 120
120 Charge
Chargequantity
quantity(to(to
discharge
discharge quantity)
quantity) 12.0
12.0
(h)

current(CA)

quantity(%)
0.2

(V)
25°C 1 Discharge 0.25CA

voltage(V)
3 80
100 8.0
10.0 80 0.25CA
0.25CA

Capacity
— 80 0.50CA
Approx. mass 13.5kg — 100% (0.05CA*20H) 6080

quantity
100 10.0

(%)
1.00CA

Chargequantity
100 10.0 0.50CA
0.50CA

current

voltage
Chargecurrent
Duration of discharge

Capacity(%)
Batteryvoltage
0.20.2
0.2
—1 50%
— (0.05CA*10H)
Discharge 2.00CA

Charge

Battery
Charge
Terminal M6 bolt/nut & M5 threaded post 6080 1 1Discharge
Discharge 6.0
8080 —
2—Charge
— 100% (0.05CA*20H) 8.0
8.0 60

Capacity
8.0 1.00CA

Capacity
—— —100%
100%(0.05CA*20H)
(0.05CA*20H) 60 3.00CA
0.1 Charge
—— 50%voltage: 13.7V (2.28V/cell)
(0.05CA*10H) 4060 1.00CA
1.00CA
2.00CA
20 hour rate 42Ah 60 4060 —Charge
— —
—50%
50%(0.05CA*10H)
(0.05CA*10H)
current: 0.15CA 4.0
6.0 2.00CA
2.00CA
0°C

Charge

Battery
Charge
Charge
60 2 Charge 6.0

Battery
Charge
60 23 2Charge
Charge
Temperature: 25°C13.7V
(77°F) 6.0 3.00CA
Capacity 10 hour rate 40Ah 0.1 Charge voltage: (2.28V/cell)
4040 3.00CA
3.00CA
0.10.1 2040 Charge
Charge
Charge
voltage:
voltage:13.7V
current:
(2.28V/cell)
13.7V
0.15CA(2.28V/cell) 2.0
4.0 2040
(25°C) 3 hour rate 32Ah 30 4040 Charge
Chargecurrent:
current:0.15CA
0.15CA 4.0
4.0
3 Temperature: Charge25°C (77°F)
current
0 3 3Temperature:
Temperature: 25°C
25°C(77°F)
(77°F) 20
1 hour rate 26Ah 20020
20 0.0
2.0
2.0
2.0 20020
0 4 8 12 Charge
16 current
20
current24
0 00
Charge current
Charge -15 0 15 30 45
-15°C 0 00 0.0
(min.)

Fully charged battery 0.0


0.0 0 00
Impedance 10mΩ 10 Charge time
(25°C) 0 00 4 44 888 12 (h)16 20 2424
1212 1616 2020 24 -15
Battery temperature (°C)
-15-15 0 00 15
1515 30
3030 45
4545
40°C 102% Charge
Charge
Charge time
time (h)
(h)(h)
time Battery
Battery temperature
temperature (°C)
(°C)
5 Battery temperature (°C)
Temperature dependency 25°C 100% 3
of capacity (20 hour rate) 0°C 85%
20.0
DISCHARGE CHARACTERISTICS
-15°C 65%
After 3 month 91% 1 20.0
20.0
20.0
Self-discharge 1 3 10 30 100 300 1,000
After 6 month 82% Discharge current (A)
(25°C) 15.0
After 12 month 64%

(V) (V)
15.0
15.0

voltage
15.0

(V)
voltage(V)
WATT TABLE (25°C) (Wattage/battery) 10.0 2.1A

voltage
Terminalvoltage
42.0A 10.5A

Terminal
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 10.0 126.0A
10.0
10.0 42.0A 10.5A 2.1A
2.1A
2.1A
9.6V 1,483 1,254 966 835 625 410 312 241 187 132 110 89.9 79.1 48.0 25.2 42.0A
42.0A 10.5A
10.5A
126.0A

Terminal
Terminal
5.0 126.0A
126.0A
9.9V 1,405 1,232 955 824 607 407 310 234 186 130 109 89.4 78.5 48.0 25.2
10.2V 1,327 1,210 943 812 596 406 307 217 184 127 108 88.9 77.9 48.0 25.2 5.0
5.05.0
10.5V 1,249 1,176 920 800 585 405 306 211 179 126 107 88.5 76.7 48.0 25.2
0.0
10.8V 1,215 1,086 886 777 573 390 295 201 173 121 105 87.5 75.5 48.0 25.2 0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.0
0.00.0 (min.) (h)
(Ampere/battery) 0 00 1 11 2 22 3 33 5 55 7
7 7 1010 10 20
2020 40 6060
4040 60 2 22 4 44 6 6 8 881010
6 10 20
2020 40
4040
AMPERE TABLE (25°C) (min.) (h)
(min.)
(min.) Duration of discharge (h)(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Duration
Duration
Duration of
ofof discharge
discharge
discharge
9.6V 133 112 84.0 72.0 53.4 34.9 26.5 20.4 15.8 11.1 9.20 7.50 6.60 4.00 2.10
9.9V 126 110 83.0 71.0 51.9 34.7 26.3 19.8 15.7 10.9 9.10 7.46 6.50 4.00 2.10
10.2V 119 108 82.0 70.0 50.9 34.6 26.1 18.4 15.5 10.7 9.00 7.42 6.50 4.00 2.10
10.5V 112 105 80.0 69.0 50.0 34.5 26.0 17.9 15.1 10.6 8.90 7.38 6.40 4.00 2.10
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 109 97.0 77.0 67.0 49.0 33.2 25.0 17.0 14.6 10.2 8.80 7.30 6.30 4.00 2.10 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

90 91
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-X1265P*1 FOR STANDBY POWER SUPPLIES. LC-X1265P*1


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS
AT 20°C ACCORDING TO EUROBAT. G199090
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
3.25A - 13.0A - 32.5A - 65.0A - 130A -
DIMENSIONS (MM) Terminal type Control voltage: 13.6V - 13.8V Discharge current
Trickle use 13.0A 32.5A 65.0A 130A 195A
18 M6 Initial current: 9.75A or smaller
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

18
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L)
100 120
350±2 166±2 100
100
100 Charging voltage 120
120
120
100
265

(%) (%)
63.5 2.275V/cell
137.8 7 18 48.2 79.8 Charging voltage

18
Charging
Charging voltage
voltage

ratio ratio
10 100
100
100
80

(%)
ratio (%)
life (years)
2.275V/cell
2.275V/cell
2.275V/cell
5°C

retention
retention ratio
1010
10 8080
80
60

life (years)
(years)
(41°F)

life (years)
5°C5°C
5°C

175±2

retention
Capacity retention
155
60
4060
60 40°C 30°C 25°C (41°F)
(41°F)
(41°F)
1

Service
Service life

Capacity
(104°F) (86°F) (77°F)
1 11 4040
40 40°C
40°C
40°C 30°C
30°C
30°C 25°C
25°C
25°C

Service
20

Service

Capacity
Capacity
(104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
(77°F)
343.6 164.5
2020
020
0.1
Contents indicated (including the recycle marking, etc.) 0 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60 0 00
are subject to change without notice. Battery case resin: standard (UL94 HB) 0.1
0.1
0.1 Storage period (mth.)
0 00 1010
10 20Temperature
2020 3030
30 (°C)
4040
40 5050
50 6060
60 0 00 2 22 4 44 6 66 8 88 1010
10 1212
12 1414
14 1616
16 1818
18 2020
20
Storage
Storage
Storage period (mth.)
period
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)
Temperature
Temperature (°C)
(°C)
Name LC-X1265PG*1 CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY
120 DISCHARGE CURRENT
20
Nominal capacity (20 hour rate) 65Ah 40°C Battery voltage
140
160
160
160 14.0
16.0
16.0
16.0 0.05CA
0.3 120
120
120
100
Length 350mm 10 Battery voltage
Battery voltage 0.10CA
120
140 Charge quantityBattery voltage
(to discharge quantity) 12.0
14.0

(CA) (CA)
140 14.0

(%) (%)
Dimensions Width 166mm
140 14.0 0.05CA
0.05CA

(V) (V)
0.3
0.3
0.3 0.05CA
100
100
100
80 0.25CA
0.10CA
0.10CA
5 100 10.0 0.10CA

quantity
120
120 12.0
12.0 0.50CA

current
120 Charge quantity
Charge (to(to
quantity discharge
(to discharge quantity)
quantity) 12.0

(%) (%)
voltage
Charge quantity discharge quantity)

(CA)

(%)
Height 175mm

current (CA)

quantity (%)
(h)

25°C 0.2

(V)
voltage (V)
1 Discharge 0.25CA
0.25CA
0.25CA
3 80 8.0 8080

Capacity
100
100 — 10.0
10.0 80

quantity
Approx. mass 23.5kg 100 10.0 60

Charge quantity
— 100% (0.05CA*20H) 0.50CA
1.00CA
0.50CA

current
0.50CA

voltage

(%)
Charge current

Capacity (%)
Battery voltage
Duration of discharge

0.2
0.2
0.2 1—
— 50% (0.05CA*10H)
1Discharge
Discharge 2.00CA

Charge
1 Discharge

Battery
Terminal M6 bolt/nut 60 6.0

Charge
8080 —Charge 8.0
8.0

Capacity
80 2— 8.0

Capacity
——
100% (0.05CA*20H) 60
—— 100%
100% (0.05CA*20H)
(0.05CA*20H) 4060
60 3.00CA
1.00CA
1.00CA
1.00CA
20 hour rate 65Ah 0.1 —Charge
— ——
50%

voltage:
(0.05CA*10H)
50%
13.7V (2.28V/cell)
(0.05CA*10H) 2.00CA
2.00CA
60 40 — 50% (0.05CA*10H) 4.0 2.00CA

Charge
Charge current: 0.15CA

Battery
6060 6.0

Charge

Charge
60 6.0

Battery
6.0

Charge
0°C 2 2Charge
Charge
2 Charge
3.00CA
3.00CA
10 hour rate 60Ah Temperature:
3 Charge 25°C (77°F) 4040 3.00CA
Capacity 0.1
0.1
0.1 Charge
Chargevoltage:
voltage:
voltage: 13.7V (2.28V/cell)
13.7V
13.7V (2.28V/cell)
(2.28V/cell) 40
20
20
4040
40 Charge
Charge
Chargecurrent:
current:
current: 0.15CA
0.15CA
0.15CA 2.0
4.0
4.0
4.0
(25°C) 3 hour rate 49Ah 30 3 3Temperature:
Temperature:
3 Temperature: Charge
25°C25°C
25°C current
(77°F)
(77°F)
(77°F)
0 020 0.0 2020
1 hour rate 40Ah 2020 2.0
2.0
2.0 020
0 00 0 4 8 12 16Charge
20current
Charge
Charge 24
current
current -15 0 15 30 45
Fully charged battery 0 00 0.0
0.0
0.0
(min.)

Impedance 7mΩ -15°C 0 00


(25°C) 10 Charge time (h) Battery temperature (°C)
0 00 4 44 8 88 1212
12 1616
16 2020
20 2424
24 -15
-15
-15 0 00 1515
15 3030
30 4545
45
40°C 102%
5 Charge
Charge
Chargetime
time(h)(h)
time (h) Battery
Battery
Batterytemperature (°C)
temperature
temperature (°C)
(°C)
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE CHARACTERISTICS
20.0
After 3 month 91% 1
Self-discharge 1 3 10 30 100 300 1,000 20.0
20.0
20.0
After 6 month 82%
(25°C) Discharge current (A)
After 12 month 64% 15.0

(V) (V)
15.0
15.0

voltage
15.0

(V)
WATT TABLE (25°C) (Wattage/battery)

voltage (V)
10.0 3.25A

voltage
16.25A

Terminal voltage
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 65.0A

Terminal
10.0
10.0
10.0
195.0A
9.6V 1,884 1,439 1,127 956 742 533 501 321 290 201 158 131 115 70.80 39.00 16.25A
16.25A
16.25A 3.25A
3.25A
3.25A
65.0A
65.0A
65.0A
Terminal
Terminal
9.9V 1,851 1,422 1,116 951 734 520 494 313 289 198 157 127 114 70.40 39.00 5.0 195.0A
195.0A
195.0A
10.2V 1,735 1,386 1,093 935 725 515 484 307 281 196 156 126 113 70.10 38.90 5.05.0
5.0
10.5V 1,554 1,284 1,017 888 709 507 474 300 272 193 154 125 112 69.70 38.80
0.0
10.8V 1,374 1,145 949 865 685 499 465 292 259 189 152 122 111 69.00 38.60 0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.00.0
0.0 (min.) (h)
0 00 1 11 2 22 3 33 5 55 7 77 1010
10 2020
20 4040
40 6060
60 2 22 4 44 6 66 8 88 1010
10 2020
20 4040
40
AMPERE TABLE (25°C) (Ampere/battery)
(min.)
(min.)
(min.) Duration of discharge (h)(h)
(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
Duration
Duration
Durationofof
discharge
of discharge
discharge
9.6V 195 129 98.0 82.4 63.4 45.4 42.2 27.2 24.5 16.9 13.2 11.1 9.60 6.05 3.27
9.9V 193 127 97.0 82.0 62.7 44.3 41.6 26.5 24.4 16.6 13.1 10.8 9.56 6.02 3.27
10.2V 183 124 95.0 80.6 62.0 43.9 40.8 26.0 23.8 16.4 13.0 10.7 9.52 5.99 3.26
10.5V 166 115 88.4 76.6 60.6 43.2 40.0 25.4 22.9 16.2 12.9 10.6 9.41 5.96 3.25
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 150 102 82.5 74.5 58.5 42.5 39.2 24.7 21.9 15.8 12.8 10.3 9.26 5.90 3.23 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

92 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-P1265PG. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-P1265PG. 93
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P1275P FOR STANDBY POWER SUPPLIES. LC-P1275P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
3.75A - 15.0A - 37.5A- 75.0A - 150A -
DIMENSIONS (MM) Terminal type Control voltage: 13.6V - 13.8V Discharge current
Trickle use 15.0A 37.5A 75.0A 150A 225A
18 M6 Initial current: 11.3A or smaller
Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

18
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L)
100 120
350±2 166±2 100
100 Charging voltage 120
120
100
265

(%) (%)
63.5 2.275V/cell
137.8 7 18 48.2 79.8 Charging
Charging voltage
voltage

18
100
100

ratio ratio
10 80

Capacity retention ratio (%)


life (years)
2.275V/cell
2.275V/cell
5°C

retention
1010 6080
80

life (years)
Service life (years)
(41°F)
5°C
5°C

175±2

retention
155
1 4060
60 40°C 30°C 25°C (41°F)
(41°F)

Service

Capacity
(104°F) (86°F) (77°F)
11 2040
40 40°C
40°C 30°C
30°C 25°C
25°C

Service

Capacity
(104°F)
(104°F) (86°F)
(86°F) (77°F)
(77°F)
343.6 164.5
20020
0.1
Contents indicated (including the recycle marking, etc.) 0 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60 00
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.10.1
00 1010 2020Temperature
3030 (°C)
4040 5050 6060 0 0 2 2 4 4 Storage
6 6 8 8period (mth.)
1010 1212 1414 1616 1818 2020
Storage
Storage period (mth.)
period (mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature
Temperature (°C)
(°C)
Name LC-P1275P CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY
120DISCHARGE CURRENT
20 40°C
Nominal capacity (20 hour rate) 75Ah Battery voltage
140
160
160 14.0
16.0
16.0
0.3 120
120
100
0.05CA
Length 350mm 10 Battery
Battery voltage
voltage 0.10CA
120
140
140 Charge quantity (to discharge quantity) 12.0
14.0
14.0

(CA) (CA)

(%) (%)
Dimensions Width 166mm 0.30.3 0.05CA
0.05CA

(V) (V)
100
100
80 0.25CA
0.10CA
0.10CA
5 100 10.0

quantity
120
120 Charge
Charge quantity (to(to
quantity discharge
discharge quantity)
quantity) 12.0
12.0 0.50CA

current
25°C

(%) (%)
voltage
Charge current (CA)

Charge quantity (%)


Height 175mm
(h)

0.2

Battery voltage (V)


1 Discharge 0.25CA
0.25CA
3 80
100 8.0
10.0 8080

Capacity
100 10.0

quantity
Approx. mass 21.5kg —
— 100% (0.05CA*20H) 60 0.50CA
0.50CA
1.00CA

current

voltage

Capacity (%)
Duration of discharge

0.20.2 — 50% (0.05CA*10H)


1 —Discharge
1 Discharge 2.00CA

Charge
Terminal M6 bolt/nut 6080 6.0

Battery
Charge
80 8.0
8.0

Capacity
2——Charge

4060
60
100%
— 100%(0.05CA*20H)
(0.05CA*20H) 1.00CA
1.00CA
3.00CA
20 hour rate 75Ah 0°C 0.1 —Charge
— — 50%
50%

voltage: 13.7V (2.28V/cell)
(0.05CA*10H)
(0.05CA*10H) 2.00CA
2.00CA
4060 4.0

Charge
60 6.0
6.0

Battery
60 Charge current: 0.15CA

Charge
2 Charge
2 Charge
3.00CA
3.00CA
2040
10 hour rate 70Ah Temperature:
3 Charge 25°C (77°F) 40
Capacity 0.10.1 voltage:
Charge 13.7V
voltage: (2.28V/cell)
13.7V (2.28V/cell)
2040
40 Charge
Chargecurrent: 0.15CA
current: 0.15CA 2.0
4.0
4.0
(25°C) 3 hour rate 53Ah 30 Charge current
3 Temperature:
3 Temperature: 25°C (77°F)
25°C (77°F)
0 20020 0.0
2.0
2.0 20020
1 hour rate 50Ah
Charge current
Charge current
-15°C 00 0 4 8 12 16 20 24 -15 0 15 30 45
Fully charged battery 00 0.00.0 00
(min.)

Impedance 7mΩ 10
(25°C) 00 4 4 Charge
8 8 12time
12 (h)
1616 2020 2424 -15
-15 00
Battery temperature (°C)
1515 3030 4545
40°C 102% Charge
Charge time
time (h)(h) Battery
Battery temperature
temperature (°C)
(°C)
5
Temperature dependency 25°C 100%
3
of capacity (20 hour rate) 0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
20.0
Self-discharge 1 3 10 30 100 300 1,000
After 6 month 82%
(25°C) Discharge current (A) 15.0
After 12 month 64%
15.0
15.0

(V) (V)
WATT TABLE (25°C) (Wattage/battery)

voltage
10.0 3.75A

Terminal voltage (V)


75.0A 18.75A
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h

voltage
10.0
10.0 225.0A 3.75A
3.75A
9.6V 2,273 1,985 1,546 1,313 962 702 555 411 327 220 171 149 125 79.5 45.0 75.0A
75.0A 18.75A
18.75A

Terminal
9.9V 2,233 1,950 1,538 1,306 955 683 553 403 325 216 169 147 124 79.1 45.0 225.0A
225.0A
5.0
Terminal
10.2V 2,093 1,827 1,531 1,290 940 679 549 400 321 215 168 146 123 78.6 45.0
5.05.0
10.5V 1,875 1,637 1,446 1,230 925 671 546 395 317 210 166 144 122 78.2 45.0
10.8V 1,657 1,447 1,400 1,200 911 580 473 355 301 205 164 143 120 77.8 44.1 0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
0.00.0 (min.) (h)
AMPERE TABLE (25°C) (Ampere/battery) 0 0 1 1 2 2 3 3 5 5 7 7 1010 2020 4040 6060 2 2 4 4 6 6 8 8 1010 2020 4040
(min.)
(min.) Duration of discharge (h)(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
9.6V 241 177 134 116 86.9 61.5 51.0 34.8 27.6 18.5 14.3 12.4 10.4 7.14 3.75 Duration
Duration of of
discharge
discharge
9.9V 237 175 132 113 86.3 59.9 50.8 34.1 27.4 18.2 14.2 12.2 10.3 7.11 3.75
10.2V 222 167 130 111 84.9 59.5 50.5 33.8 27.1 18.1 14.0 12.1 10.2 7.07 3.75
10.5V 199 159 126 109 83.6 58.9 50.2 33.4 26.8 17.7 13.9 12.0 10.1 7.04 3.75
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 176 151 122 106 82.3 50.8 43.5 30.1 25.4 17.3 13.7 11.9 10.0 7.00 3.68 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

94 95
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-XB12100P*1 FOR STANDBY POWER SUPPLIES. LC-XB12100P*1


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
5.00A - 20.0A - 50.0A - 100A - 200A -
DIMENSIONS (MM) Terminal type Control voltage: 13.6V - 13.8V Discharge current
Trickle use 20.0A 50.0A 100A 200A 300A
26 Initial current: 15.0A or smaller
M8 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

24
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L) 100 120
407±2 173±2
100
100
100 Charging voltage 120
120
100
120
275±2 110

ratio (%)
8 2.275V/cell

26
24
10 Charging
Chargingvoltage
Charging voltage
voltage 100
100
80
100

ratio (%)
life (years)

ratio (%)
2.275V/cell
2.275V/cell
2.275V/cell 5°C

retention
10
10
10 80
80
60
80 (41°F)

life (years)
life (years)
5°C
5°C
5°C

210±2

retention
retention
1 60
60
40
60 40°C 30°C 25°C (41°F)
(41°F)
(41°F)

Service

Capacity
(104°F) (86°F) (77°F)
111 40
40
20
40 40°C
40°C
40°C 30°C
30°C
30°C 25°C
25°C
25°C

Service
Service

Capacity
Capacity
(104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
(77°F)
406 172 0.1 20
20
0
20
Contents indicated (including the recycle marking, etc.) 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: standard (UL94 HB) 0.1
0.1
0.1 000
Storage period (mth.)
Temperature (°C) 000 222 444 666 888 10 10 12
10 12 14
12 14 16
14 16 18
16 18 20
18 20
20
000 10
10
10 20
20
20 30
30
30 40
40
40 50
50
50 60
60
60
Storage
Storageperiod
Storage period(mth.)
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature
Temperature(°C)
Temperature (°C)
(°C)
Name LC-XB12100P* 1
CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V 160
CHARGE CHARACTERISTICS FOR TRICKLE USE 16.0 AND BY
120 DISCHARGE CURRENT
20 Battery voltage
Nominal capacity (20 hour rate) 100Ah 40°C 140 14.0
0.3 160
160 16.0
16.0 120
120
120
100
0.05CA
Length 407mm 10 Battery voltage 0.10CA
120 Charge quantityBattery
Battery voltagequantity)
voltage
(to discharge 12.0

(CA) (CA)

(%) (%)
140
140 14.0
14.0

(V) (V)
Dimensions Width 173mm 0.3 0.05CA
0.05CA
0.05CA
0.25CA
0.3 100 10.0 100
100
100
80 0.10CA

quantity
5 0.10CA
0.10CA
0.50CA

current

(%) (%)
120 12.0

voltage
120 Charge
Charge
Charge quantity (to(to
quantity
quantity discharge
(to discharge
discharge quantity)
quantity)
quantity) 12.0

(CA)

(%)
Height 236mm 0.2
(h)

1 Discharge

(V)
25°C 80 8.0 0.25CA
0.25CA
0.25CA

Capacity
3 100 —
— 100% (0.05CA*20H) 10.0 80
80
80
60

quantity
Approx. mass 100 10.0 1.00CA

quantity
36.5kg 0.50CA
0.50CA

current
0.50CA

(%)
voltage
current

voltage
0.2 — 50% (0.05CA*10H)
Duration of discharge

0.2 — 2.00CA

Charge
60 6.0

Battery
1 11Discharge

Charge
Terminal M8 bolt/nut Discharge
Discharge
2—Charge
80
80 8.0
8.0

Capacity
Capacity
—— —
—100%
— 100%
100%(0.05CA*20H)
(0.05CA*20H)
(0.05CA*20H) 60
60
60
40 3.00CA
1.00CA
1.00CA
1.00CA
0.1 ——
Charge voltage: 13.7V (2.28V/cell)
20 hour rate 100Ah 40 — —
—50%
50%
50%
Charge(0.05CA*10H)
(0.05CA*10H)
(0.05CA*10H)
current: 0.15CA 4.0 2.00CA
2.00CA
2.00CA

Charge
60 6.0

Battery
Charge

Charge
60 60 6.0

Battery
Charge
23 22Charge
Charge
Charge
10 hour rate 98Ah 0°C Temperature: 25°C (77°F)
40
40 3.00CA
3.00CA
3.00CA
Capacity 0.1
0.1 20 Charge
Charge
Chargevoltage:
voltage:
voltage:13.7V
13.7V
13.7V(2.28V/cell)
(2.28V/cell)
(2.28V/cell) 2.0 40
20
(25°C)
40
40 Charge
Charge
Chargecurrent:
current:
current: 0.15CA
0.15CAcurrent
0.15CA
Charge
4.0
4.0
3 hour rate 87Ah 30 0 3 33Temperature:
Temperature:
Temperature: 25°C
25°C
25°C (77°F)
(77°F)
(77°F)
0
20 0.0
2.0 20
20
20
0
1 hour rate 65Ah 20 2.0
0 4 8 12 16Charge
20current
Charge
Charge 24
current
current -15 0 15 30 45
00 00 0.0
0.0
Fully charged battery 000
(min.)

Impedance 5.0mΩ 10 -15°C Charge time (h) Battery temperature (°C)


(25°C) 00 44 88 1212 1616 2020 2424 -15
-15
-15 000 15 15
15 30
30
30 45
45
45
40°C 102% Charge
Chargetime
Charge time(h)
time (h)
(h) Battery
Batterytemperature
Battery temperature(°C)
temperature (°C)
(°C)
5
Temperature dependency 25°C 100%
of capacity (20 hour rate)
3
0°C 85%
-15°C 65% DISCHARGE
20.0 CHARACTERISTICS
After 3 month 91% 1 20.0
20.0
20.0
Self-discharge 1 3 10 30 100 300 1,000
After 6 month 82%
(25°C) Discharge current (A) 15.0

(V) (V)
After 12 month 64%

voltage
15.0
15.0
15.0

(V)
WATT TABLE (25°C) (Wattage/battery) 10.0

voltage
voltage
100.0A 25.0A 5.0A

Terminal
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h 200.0A
300.0A
10.0
10.0
10.0 5.0A
5.0A
5.0A
9.6V 3,504 2,698 2,275 1,776 1,258 904 880 502 411 292 221 188 150 95.0 48.1 100.0A
100.0A
100.0A 25.0A
25.0A
25.0A

Terminal
200.0A

Terminal
300.0A 200.0A
200.0A
9.9V 3,266 2,639 1,973 1,683 1,239 878 795 493 408 287 219 185 149 95.0 48.1 5.0 300.0A
300.0A
10.2V 2,890 2,534 1,920 1,651 1,229 850 779 489 403 285 217 181 148 94.1 48.1
5.0
5.0
5.0
10.5V 2,498 2,379 1,849 1,601 1,200 738 762 483 398 278 214 180 147 94.1 48.0
0.0
10.8V 2,375 2,178 1,756 1,544 1,199 734 758 435 378 272 212 179 144 93.1 47.3
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
0.0
0.0
0.0 (min.) (h)
AMPERE TABLE (25°C) (Ampere/battery) 000 111 222 444 666 888 10 10
10 20
20
20 40
40
40 6060
60 222 444 666 888 10
10
10 20
20
20 40
40
40
(min.)
(min.)
(min.) Duration of discharge (h)
(h)
(h)
Cut-off 5min. 10min. 15min. 20min. 30min. 45min. 1h 1.5h 2h 3h 4h 5h 6h 10h 20h
9.6V 365 281 237 185 131 94.2 87.3 52.3 42.8 30.4 23.0 19.5 15.7 9.90 5.01 Duration
Durationofof
Duration ofdischarge
discharge
discharge
9.9V 340 275 206 175 129 91.5 78.9 51.3 42.5 29.9 22.8 19.2 15.6 9.90 5.01
10.2V 301 264 200 172 128 88.5 75.5 50.9 42.0 29.7 22.6 18.9 15.5 9.80 5.01
10.5V 260 248 193 167 125 76.9 75.0 50.3 41.5 29.0 22.3 18.8 15.3 9.80 5.00
The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Regarding handling and safety
10.8V 247 227 183 161 125 76.4 74.9 45.3 39.4 28.3 22.0 18.7 15.0 9.70 4.92 please consult our VRLA technical handbook chapter 1.
All mentioned values are average values

96 *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-PB12100P. *1 This battery is also available with a flame retardant battery case resin (UL94 V-0): LC-PB12100P. 97
13 INDIVIDUAL DATA SHEETS INDIVIDUAL DATA SHEETS 13

LC-P12120P FOR STANDBY POWER SUPPLIES. LC-P12120P


EXPECTED TRICKLE DESIGN LIFE: 10 – 12 YEARS AT 20°C
ACCORDING TO EUROBAT.
CHARGING METHOD (25°C) CUT-OFF VOLTAGE
6.00A - 24.0A - 60.0A - 120A - 240A -
DIMENSIONS (MM) Terminal type Control voltage: 13.6V - 13.8V Discharge current
Trickle use 24.0A 60.0A 120A 240A 300A
26 Initial current: 18.0A or smaller
M8 Cut-off voltage 10.5V 10.2V 9.9V 9.3V 8.7V

24
INFLUENCE OF TEMPERATURE ON TRICKLE LIFE
(L) 100 120
407±2 173±2
100100
100 Charging voltage 120120
100
120
275±2 110

ratio (%)
8 2.275V/cell

26
24
Charging
Chargingvoltage
Charging voltage
voltage 100100
10 80
100

ratio (%)
(%)
life (years)

ratio (%)
2.275V/cell
2.275V/cell
2.275V/cell 5°C

retention
retention ratio
1010
10 80
6080
80

life (years)
(41°F)

(years)
life (years)
5°C5°C
5°C

210±2

retention
Capacity retention
1 60
4060
60 40°C 30°C 25°C (41°F)
(41°F)
(41°F)

Service

Capacity
Service life
(104°F) (86°F) (77°F)
1 11 40
2040
40 40°C
40°C
40°C 30°C
30°C
30°C 25°C
25°C
25°C

Service
Service

Capacity
Capacity
(104°F)
(104°F)
(104°F) (86°F)
(86°F)
(86°F) (77°F)
(77°F)
(77°F)
406 172 2020
020
0.1
Contents indicated (including the recycle marking, etc.) 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
are subject to change without notice. Battery case resin: flame retardant (UL94 V-0) 0.10.1
0.1 0 00
Storage period (mth.)
Temperature (°C) 0 00 2 22 4 44 6 66 8 88 1010
101212
121414
141616
161818
182020
20
0 00 1010
10 2020
20 3030
30 404040 5050
50 6060
60
Storage period
Storage
Storage (mth.)
period
period (mth.)
(mth.)
SPECIFICATIONS DURATION OF DISCHARGE VS. DISCHARGE CURRENT Temperature (°C)
Temperature
Temperature (°C)
(°C)
Name LC-P12120P CONSTANT-VOLTAGE CONSTANT-CURRENT DISCHARGE CAPACITY BY TEMPERATURE
30
Nominal voltage 12V CHARGE CHARACTERISTICS
160 FOR TRICKLE USE 16.0 AND BY
120 DISCHARGE CURRENT
20 Battery voltage
Nominal capacity (20 hour rate) 120Ah 40°C 140 14.0
0.3 160 160
160 16.016.0
16.0 120120 0.05CA
Length 407mm 10 120
100 0.10CA
Battery voltage
Battery voltage
120 Charge quantityBattery
(to voltage
discharge quantity) 12.0

(CA) (CA)

(%) (%)
140 140
140 14.014.0
14.0 0.05CA

(V) (V)
Dimensions Width 173mm 0.3 0.3
0.3 100100
0.05CA
0.05CA
0.25CA
100 10.0 100
80 0.10CA
0.10CA

quantity
5 120 12.0 0.10CA
0.50CA

current

(%) (%)
voltage
120
120 Charge quantity
Charge (to
quantity discharge
(to dischargequantity)
Charge quantity (to discharge quantity)quantity) 12.0
12.0

(CA)

(%)
Height 236mm

current (CA)
0.2

quantity (%)
(h)

1 Discharge

(V)
25°C

voltage (V)
80 8.010.0 0.25CA
0.25CA
0.25CA
3 80

Capacity
100 — 10.0 80
80

quantity
Approx. mass 34.5kg 100
100 — 100% (0.05CA*20H)
10.0 60 1.00CA

Charge quantity
0.50CA
0.50CA

current

voltage
0.50CA

(%)
Charge current

Capacity (%)
Battery voltage
Duration of discharge

0.2 0.2 60
0.2 —— 50% (0.05CA*10H) 2.00CA

Charge
1 1Discharge

Battery
Discharge 6.0

Charge
Terminal M8 bolt/nut 1Discharge
808080 2— Charge 8.0 8.0

Capacity
— 8.0

Capacity
——100%
——100% (0.05CA*20H)
100% (0.05CA*20H)
(0.05CA*20H) 60 60
60
40 3.00CA
1.00CA
1.00CA
1.00CA
20 hour rate 120Ah 0.1 — Charge
— —
voltage: 13.7V (2.28V/cell)
40 50%
—— (0.05CA*10H)
50%(0.05CA*10H)
— 50%
Charge (0.05CA*10H)
current: 0.15CA 4.0 2.00CA
2.00CA
2.00CA

Charge

Battery
6060 6.0

Charge
60 6.0

Charge
60

Battery
6.0

Charge
0°C 2 2Charge
Charge
2Charge
3 Temperature: 25°C (77°F) 3.00CA
10 hour rate 110Ah 40 40 3.00CA
3.00CA
Capacity 0.1 0.1 20
0.1 Charge voltage:
Charge
Charge 13.7V
voltage:
voltage: (2.28V/cell)
13.7V
13.7V (2.28V/cell) 2.0
(2.28V/cell) 40
20
(25°C)

You might also like