iPASOLINK Introduction 45
ODU Alarm and Status
Indication Category Descriptions Severity
TXPWR ALM Alarm The TX PWR is lower than 3 dB. MJ
TX INPUT ALM Alarm The TX IF signal become out of range from MJ
-29 dBm 5 dB.
RXLEV ALM Alarm The reception level become lower than -72dBm ~ -94dBm level.(It MJ
depends on the modulation system and bit rates).
ODU CPU / Cable CPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken MJ
Alarm
Open or is not connected.
Indicates the control status of the ODU TX power output. When the TX
MUTE STATUS Status -
power is set to Mute, Status is issued.
LO REF Alarm Loss of Ref LO signal of ODU. MN
TX SW Status Status Radio interface TX SW usage state in 1+1 HS Redundant configuration -
Indicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM,
ODU ALM Alarm MJ
ODU SELF CHECK ALM occurrence
Highest
Indicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU
ODU TOTAL ALM Alarm severity will
CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.
be displayed
ATPC Power ATPC control signal fault (90sec) as well as MAX Power continuation
Status -
Mode 90sec
ODU TYPE Indicate connected ODU type is not supported at iPASOLINK system, or
Alarm MJ
MISMATCH ODU type cannot use in provisioned modulation setting.
ODU PS ALM Alarm ALM in a case of Power supply interruption to ODU. MJ
ODUPS SET Status Status indication of the protection switch for ODU power supplies -
STATUS
iPASOLINK Introduction 46
Modem Alarm and Status
Indication Category Descriptions Severity
Unequipped (MODEM-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(MODEM-A) Alarm The equipped type of interface is different from configured type. MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
HIBER ALM Alarm Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5) MJ
LOBER ALM Alarm Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9) MN
EARLY WARNING Alarm Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9) MN
MOD Alarm Indicates the operating status of the MOD. When any failure occurs in the modulator section, Alarm is issued. MJ
INPHASE. Status In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase -
condition. In this condition, hitless switch over is available.
L2SYNC LOSS Alarm Loss of frame synchronization of GFP frames on MODEM port. MJ
TDM/AMR Range Mismatch Alarm Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or MJ
mismatch condition of selected RX AMR modulation range and TX AMR modulation range.
TX SW Reverse Request Status TXSW request signal receiving condition from the opposite station: -
MODEM PS OFF Status Indicate power off condition of power switch which is in front of MODEM-A card. -
iPASOLINK Introduction 47
STM-1 Alarm and Status
Indication Category Descriptions Severity
Unequipped (STM1-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(STM1-A) Alarm The equipped type of interface is different from configured type. MJ
Communication
Alarm Communication failure of equipment internal control communication. MJ
FAIL(STM1-A)
Module(STM1-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
SNCP Protection Status Status SNCP Path Protection Status indication which indicates [FS, SF, SD, MS, NR] condition. -
APS Protection Status Status APS Line Protection Status indication which indicates {FS,SF,SD,MS,NR} condition. -
RS LOF Alarm SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port. MJ
RS TIM Alarm Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port. MJ
RS DEG Alarm B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port. MN
MS RDI Alarm Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port. MJ
iPASOLINK Introduction 48
STM-1 Alarm and Status
Indication Category Descriptions Severity
HP UNEQ Alarm HOP (Higher Order Path) Unequipped occurrence on STM-1 port. MJ
HP TIM Alarm HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port. MJ
HP-PLM Alarm Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port. MJ
HP-RDI Alarm RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port. MJ
LP RDI Alarm Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port. MJ
LP PLM Alarm Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port. MJ
ALS Status Indication of automatic laser shutdown condition at STM-1 optical port. -
RS UAS Status Status UAS status indication on STM port (Repeater Section) -
iPASOLINK Introduction 49
16E1 alarm and Status
Unequipped (16E1) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(16E1) Alarm The equipped type of interface is different from configured type. MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
E1 AIS Status ALARM/Status category can change according to " AIS Received Condition MJ / -
Setting
iPASOLINK Introduction 50
AUX-A Option Card
Item Name (Input-x) Status/ HKA Status Indication {Alarm, Normal} for every - or
Item Name (Cluster-x) Alarm HKA input. Severity selectable
Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -
iPASOLINK Introduction 51
GbE-A option card
iPASOLINK Introduction 52
Equipment Common alarm and Status-1
Unequipped (PS) Alarm Installed Power Supply Module is removed from PS slot. MJ
Unequipped (FAN) Alarm Installed FAN Module is removed from FAN slot. MJ
Unequipped (CLK2M) Alarm Installed CLK2M Module is removed from Main Card. MJ
Type Mismatch (CLK2M) Alarm The equipped type of interface is different from configured type. MJ
SSM FAIL Alarm Received Sync Status Message value is in unstable condition. MN
Quality Level Status Received quality level condition of each timing source. -
iPASOLINK Introduction 53
Equipment common Alarm and Status -2
Indication Category Descriptions Severity
EXT CLK Condition Status Condition level of External CLK output. -
EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN
EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input. MN
EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN
EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output. MJ
Item Name (Input-x) Status/ - or Severity
Item Name (Cluster-x) Alarm HKA Status Indication {Alarm, Normal} for every HKA input. selectable
Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -
SFP_Type Mismatch (ETH) Alarm Mismatch between SFP on LCT and installed SFP. MJ
ETH-OAM Unexpected Period Alarm Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice MN
iPASOLINK Introduction 54
Equipment common Alarm and Status -3
Indication Category Descriptions Severity
RSTP New Root Bridge Detect Status The notice in which new RootBridge was detected at the time of SpanningTree processing -
RSTP Topology Changed Status The notice in which a Topology change was detected at the time of SpanningTree processing -
The notice which received a Bridge protocol Data Units different in classification of RSTP/STP at the
RSTP Protocol Migration Status time of SpanningTree processing -
RSTP Invalid BPDU Received Status Invalid BPDU message at the time of SpanningTree processing -
Loss of a conditional signaling in which the LLF control signal should be received continuously from
LLF Message Timeout Status the opposite radio equipment.
LLF Status LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN. -
The highest
Severity will
IDU TOTAL ALM Alarm IDU TOTAL ALM be reported
Total FDB Full Status The number of DynamicEntryDynamic Entry in L2Switch has reached the maximum number.
FDB Full Status FDB Full indication specified per VLAN basis.
iPASOLINK Introduction 55