You are on page 1of 3

ALARM OBJECT 7651 61151 61059 7653 7771 61029 61028 61152 WBTS WBTS WBTS WBTS WBTS

WBTS WBTS WBTS

ALARM TEXT BASE STATION OPERATION DEGRADED AIS on unit 1, interface 1/2/3. PDH Timing source lost on unit 1, interface CELL FAULTY WCDMA CELL OUT OF USE LOS on unit 1, interface 3/1/2. LOS on unit 1, interface 3/1/2. RDI on unit 1, interface 1/2/3.

7654

WBTS

CELL OPERATION DEGRADED

7750

WBTS

FAILURE IN WCDMA WBTS O&M CONNECTION

SUPPLEMENTARY INFO BTS reference clock missing

VSWR alarm /RF module failure /Failure in optical RP3 interface Resource status indication, cell disabled

RF module failure /Antenna Line failure /Rx signal level failure /VSWR alarm

SUGGESTED Sync Missing, Assign to field ,Provide the E1 for sync. ATM site. E1 break is observed in interface , to be checked from field & provide the E1. ATM site. E1 break is observed in interface , to be checked from field & provide the E1. VSWR alarm. To be checked from field /SW to be checked for latest version. If then also not corrected means RF module needs to be replaced. /Optical fiber & OTR b/w system module & rf module have to be checked from field. VSWR alarm to be checked from field /SW to be checked for latest version. If then also not E1 break is observed in interface 1. To be checked from field E1 break is observed in interface 1. To be checked from field ATM site. E1 break is observed in interface 1/2/3.check for the E1 cable ,E1 port ,check the loop at The RX signal level is less than -112dBm or the difference between the maximum and minimum power levels of all RX antennas in the same cell and sector is more than the limit (4dB). Check RX level using WBTS manager. Check the antenna cables. The radio module, antenna feeder, or antenna is faulty on the antenna line which has the inadequate RX level. Check and replace the faulty equipment /check for vswr it might be high / rest the rf module if required / replace the RF module final step. Site down kindly visit the site to check fault

You might also like