You are on page 1of 110
nN MESC anfojeze9 $a|qeQ |04]U09 SS9904 4 79 UO!Je}UAaLUNAYsUT ‘;el4}sNpUy at the heart of every project INTRODUCTION MESC is considered the leading manufacturer and supplier of all types of cables to EPC contractors for ‘mega projects in the Middle East and North Africa. Middle East Specialized Cables Co. (MESC) was founded as a privately owned company in Riyadh Ih 1993 to cater the arowing Industry of specialized cables in the region, It started rolling its machines in 1994 and selling in 1995. After consolidating its presence In KSA as the market leader, MESC succeeded in penetrating other markets in GCC, Middle East, North Africa, Europe and USA. In 2007 it became a joint stock company and its shares floated on Saudi stock market. Over the years, MESC has expanded its production to cover all types and ranges of cables by acquiring existing companies, establishing new companies and Joint ventures. Its products range includes the Industrial, Instrumentation and Process Control Cables, Special Cables (BMS), Low Voltage Power Cables, Medium Voltage Power Cables, Overhead Lines, Offshore Cables, Railway Signaling and Power Cables and any type of customized cables manufactured as per the customers’ needs and specifications: MESC plants, located respectively in Saudi Arabia, Jordan and UAE, consist of titra modern facilities, high-tech machinery and well-equipped laboratories, built for conducting various routine and type tests. ‘They operate with clearly defined and documented quality systems set in accordance with the guidelines of 1509001:2004, 1S014001:2004 and OHSAS 18002 for all activities right from the selection of raw material suppliers, schedule planning, production, testing and to the delivery of cables, with a policy aiming for total customer satisfaction. The Medium Voltage Cables are produced in the technical collaboration of Fujikura Japan. MESC products are manufactured to international standards, tested and certified by prestigious institutions such as: 3P (Denmark), BASEC, BSI (UK), Cable Technology Laboratories Inc. (USA), CSA (Canada), IMQ (Italy), KEMA (Netherlands), Jordanian Institution for Standards and Meteorology (JQM), Saudi Arabian Standards Organization (SASO), UL (USA),VDE (Germany), Warrington Fire Research (UK). MESC products are approved by all oll, gas, petrochemical, power and water desalination utilities in the MENA region, such as: Aramco, Sabic, STC, SEC (KSA), Kuwait Oil Co. (KOC), KNPC (Kuwait), Qatar Petroleum, MEW (Qatar), ADCO, GASCO, ADNOG (UAE). They are also approved by many major international EPC contractors such as: ABB, ABV Rock Group, Bechtel, Daelim Engineering Co., Doosan Heavy Industries, Fisia Itallamaplanti, Fluor Daniel, Hyundai Engineering & Construction Co., JGC Corporation, NPCC, Siemens, SK Engineering, Snamprogettl, Technicas, Technip, Toyo Engineering Co., and many others. CERTIFICATE TUVNORD Management system as per EN ISO 9001 : 2008 In accordance with TOV NORD CERT procedures, itis hereby certified that MIDDLE EAST SPECIALIZED CABLES - MESC Member of MESC Group P.O. Box 585, Riyadh - 11383, Kingdom of Saudi Arabia ‘applies a management system inline withthe above standardor the following soope Manufacture and sale of industrial, instrumentation, process control, data, system, coaxial, telephone, fire resistant and low voltage power & control cables Certificate Registration No. 44 100 091617 ali unt 2073-09-04 ‘Audit Repon No, 3508 2578 CO. Brdatigom cattitston Bay Econ, 2010-03-02 Se TOVNORD CERT Gril ‘This certification was conducted in accordance withthe TCV NORD CERT auslling and cartication procedures and is subject to regular surveliance audits, ‘TOV NORD CERT GmbH LLangemarckstrasse 20 45141 Besson wer tuev-nord-cer. oo e@ INDEX A. INSTRUMENTATION CABLE - TYPE PLTC 1 MULTT CONDUCTOR, XLPE, UNSHTELOED 2 MULTI CONDUCTOR, XLPE, SHIELDED 3 MULTI CONDUCTOR, PVC, UNSHIELOED 4 MULTI CONDUCTOR, PVC SHIELOED 5 MULTI PAIR/TRIAD, XLPE, UNSHIELDED 6 MULTI PAIR/TRIAD, XLPE, OVERALL SHIELDED. 7 MULT) PAIR/TRIAD, XLPE, INDIVIDUAL & OVERALL SHIELDED 8 «MULTI PAIR/TRIAD, XLPE, OVERALL SHIELDED, ARMOURED. 9 MULTI PAIR/TRIAD, XLPE, INDIVIOUAL & OVERALL SHIFLOED, ARMOURED. 10 MULTI PAIR/TRIAD, PVC, UNSHIELDED 11 MULTI PAIR/TRIAD, PVG, OVERALL SHIELDED 12 MULTI PAIR/TRIAD, PVG, INDIVIDUAL & OVERALL SRIELDEO B. THERMOCOUPLE EXTENSION CABLE - TYPE PLTC MULTI PAIR, UNSHIELDED MULTI PAIR, OVERALL SHIELDED MULTI PAIR, INDIVIDUAL & OVERALL SHIELDED MULTI PAIR, OVERALL SHIELDED, ARMOUREO. MULTI PAIR, INDIVIDUAL & OVERALL SHIELDED, ARMOURED . INSTRUMENTATION CABLE - TYPE TC MULTI CONDUGTOR, XLPE, UNSHIELDED MULTI CONDUCTOR, XLPE, SHIELOED MULTI CONDUCTOR, PVC, UNSHIELDED MULTI CONDUCTOR, PVG, SHIELDED MULTI PAIR/TRIAO, XLPE, UNSHIELDED MULTI PAIR/TRIAD, XLPE, OVERALL SHIELDED MULTI PAIR/TRIAD, XLPE, INDIVIDUAL & OVERALL SHIELOED. MULTI PAIR/TRIAD, PVC, UNSHIELDED MULTI PAIR/TRIAD, PVC, OVERALL SHIELDED MULTI PAIR/TRIAD, PVG, INDIVIDUAL & OVERALL SHIELDED MULTI PAIR/TRIAD, XLPE, OVERALL SHIELDED, ARMOURED, MULTI PAIR/TRIAD, XLPE, INDIVIDUAL & OVERALL SHIELDED, ARMOURED . ELECTRONICS, COMPUTER & DATA CABLES Sencar Hoare JE-LY (3b Instr Eketrene RE-2VCYPU Istnmertaton Gy, bata ransisen . FIRE RESISTANT CABLE “MESGOFIRE* (FIRE SURVIVAL CABLES) CONTROL, MULTICORE, OVERALL SHIELDED INSTRUMENTATION MULTI PAIR, OVERALL SHIELDED INSTRUMENTATION MULTI PAIR, INDIVIDUAL & OVERALL SHIELDED LOW VOLTAGE POWER ANO CONTROL INSTALLATION, SINGLE CORE = 1 2 3 4 é F. INSTRUMENTATION CABLE - LEAD SHEATHED CABLE 2 a G 1 2 3 4 P| in pwn weeny Dee pe aveusunn| MULTIPAIR INDIVIDUAL1& COLLECTIVELY SCREENED SINGLE & MULTIPAIR COLLECTIVELY SCREENED CONTROL CABLES . TECHNICAL INFORMATION PAIRED CABLE PARAMETERS DIMENSION AND CAPACITY OF WOODEN REELS: MAXIMUM PULLING TENSION AMERICAN WIRE GAUGE EQUIVALENTS MESC Pages 13 a6 7-5 10-12 13-15 1e-17 18-39 20-21 22-23 24-26 27-29 30-32 33,34 3536 37/38 39,40 a1 42 43-45 46-48 49-51 52-54 55-57 58-60 61-63 64-66 67-69 70-72 73-74 75-76 7 78 79 20 81-83 84-85 86 87 28 29, 90 91-93 94.96 97-98 101 102 103, 104 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) XLPE INSULATED MULTICONDUCTOR UNSHIELDED CABLES Temperature range - 40°C to +90°C Specifications: UL13 es TWSTRUMENTATION TYPE PLTC (UL) 300 MESC 2010 Appticatton Industrial. signalling and process control circuit in dry or wot locations. The cable can be used in cable trays conduit or direct burial application © Conductor : Tinned copper to ASTM B33, stranded to class B of ASTM B8. © Insulation + Flame retardant XLPE to ICEA $-82-552, © Assembly Insulated cores are cabled with suitable non-hygroscopic fillers and polyester binder if necessary. © Jacket : Extruded black PVC as per ULL13, oil and sunlight resistant, passes flame test as per IEEE - 383 ( 70000 BTU ). The jacket is impervious to vapour and moisture penetration. Colour Code Conductor No. Colour 1 Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request Sin MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) XLPE INSULATED MULTICONDUCTOR UNSHIELDED CABLES Be] oner WESC Case Condicios | Santa X | tnsaaion | Woninaldacter | Approx] Apmon Diameter | themes | tlckness 00. | Weign awer | We. NoxXnm on oH rom | Kadkon ‘1001 O14 G2CZ0AWG-UOBKEOS 2 7X0.307 038 087 56S 1002 0124-03¢20aWG-UoBKe-03 3 7%0307 038 089 5848 1003 0124-04¢200WG-UoRKaOs 4 7x0307 038 oso 6388 1004 0124-05¢20ANNG-UoaKE-03 5 7%0307 0.38, 101 ee 68 01005 0124-06¢200WG-U0BKEOS —& 70.307 0.38 do. 7a a 02006 0124-076 200WG-U0BKG-03 7 70307038 101 7B es 01007 0124-08C200WG-U0BKE0s 8 7x0307 038 101 Ba 9” 01008 0124-09C20AWG-U0BKB-03 9 7%0.307 038 101 89 108 01009 0124-10C20AWG-U0BK8-03 10 7%0.307 0.38. 101 96 is 20 01010 0124-12620AWG-U0BK8-03. 12 70307 0.38 Lz 104 a3 91011 0124-15C200WG-U0BKBOs 15 7%0307 0.38. 127 nan O1012 0124-16C20AWG-U0BKE-03 16 7%0307 038 a7 n4 180 01013 0124-19¢20AWG-U0BKB-03 19 7K0307 0.38. 127 m9 201 1014 0124-20¢20AWWG-U0BKA.03 20 7x0.307 038 127 ws 4 01015 0124-24¢20AWG-UOBKE-03 24 7%0307 0.38 127 13727 01016 0124-25C200WNE-UOBKE-03 25 7%0.307 038 127 7254 e101? 0124-27C200WG-U0BKa-0s 27 7x0207 038 127 40270 oro1e 0124-30¢20aWG-UoaKa0s 30 7%0307 0.38 127 a 291 01019 0124-37C70aWG-U0BKB-03 37, 7x0307 0338 152 160367 01020 0124-48C20AWG-U0BK8-03 48 7%0.307 0.38 152 18054 91021 _0124-61620AWG-UOBKB-OS 61 70.307 0.38. 12 396 358 Se] tae WEST Come Torsion | Sane X | Imcnton | Woaaltacker | Arwon | Apron ‘ameter | ticket ‘hick Oo. | Wegnt awa | we Noon na om mm | Kalk ‘o10g2 dizaoRG1eAWG-UOBKeOS = 7x0386 038 089 oo SB 02023 0124-03CiaawG-UoBKE-03 3 70386 0.38 089 oa 6 01024 o124-04CrRAWG-UOBKA-03 4g 7K0.98 038 0.89 6978 01025 0124-05C1aAWG-UOBKB-OS 5 7%0.386 038 101 77 34 01026 0124-06C1aAwG-UOBKO-03g 7x0386 038 201 BS 106 01027 0124-07¢1BAWG-UORKA-03 7 7X03 0.38 LoL es om 01028 0124-08Ci8ANG-UOBKB-03 7x0.38 0.38 101 92 18 1029 0124-09C1aAWG-UoRKA-03 9 7K0386 0.38 101 oa 14a 01030 0124-10C18AWG-U0BKA-03 10 7x0.386 = 038 127 nae? 3801031 0124-12¢38AWG-UoRKe-0? 12 7%0.386 038 127 4189 01032 0124-15C18AWG-U0BKe-02 15 7x0.386 038 127 Rs 228 02033 O124-16CBAWG-UOBKE-O3 16 70.386 0.38 1237 Bs 238 01034 0124-19C18AWG-U08KB-03 19 7K0386 0.38. 127 asl 270 01035 0124-2008AWG-U0BKB-03 20 7%0386 038 uaz Bs (87 01036 0124-24C8AWG-UOBKB-03 24 7x0386 038 127 isa 332 01037 0124-25¢1aAWG-U0BKAO3 25 7x03 0.38 127 asa 2 01038 0124-27018AWG-U0BKE-0s 27 7K0.986 0.38 1s2 159382 01039 0124-30CiBAWG-U0BKe-03 30 7K0386 038 152 16520 100 0124-37CisAWG-UOBKe-Os 37 7x0386 038 152 y7 499 O10#L 0124-48ClBAWG-UOBKAO3 48 7x0.386 038 152 2000425 1042 _O124-61CL@AWG-UOBKE-O3 I 7x0.386 038 152 217767 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) XLPE INSULATED MULTICONDUCTOR UNSHIELDED CABLES Sas] der WESC Cote Genduceee | Sande X | Treation | Nominal acket | Aap Diameter | thickness | thickness Oo. | weigh owe | no. Nexen | mm om inos_| Kaan (104s 0124 G2CTGAWG-UOBKE-OS z 7x0.488 0.38 0.89 6 6 (01046 0124-03¢26AWG-UOBKe-03 3 7%0.488 0.38, 0.89 70 a 01045 0124-08¢164WG-LOBKA-03 a 70.088 038 01 78 108 01046 0124-0sC26AWG-UOBKE03 5 70.488 038, row ass 01047 0124-06C264W16-U0BKa-03 6 7x0.088 = 038 Lo. 34 1a 01048 0124-070 16AWG-UOBKAOD 7 7x0.488 0.28, 101 94 150 01049 0124-08¢16AWG-U0BKa-03 8 7x0.a88 0.38 127 307186 (01050 0124-09C 16aW6-U0BKE-03 a 7x0.488 038 27 a2 01052 O124-10C16AWG-UOBKA-0S 10 7x0.a88 038 127 3s 1 01052 0124-12C16AWE-UoRKBOS 12 7x0.488 0.38 1.27 26 255 01083 o124-15C26AWG-UORKE0S 15 7x0.488 038 127 390 01054 o124-16CI6AWE-UOBKE0S 16 7xoaee 0.38 127 937 01055 0124-19C16AWG-U0BK8-03 19 7x0.488 0.38 127 we 373 01056 0124-20C16AWG-UOBK8-03 20, 70.488 0.38 a2 154398 01057 0124-24C1bAWG-UOBKA03 24 7x08 = 0.38 1s2 v4 a3 01058. 0124-25C16AWG-U0BK803 25, 7%0.488 0.38 12 Va 498 01059 0124-270 16AWG-U0BKG-03 27 7%0.488 038 152 78932 01060 0124-30C16AWG-U0BK8-03 30 70.488 038 182 aa 582 01061 o124-37C26aWG-UOBKe-03 37 7x0.498 0.38 152 ie 698 01062 0124-48C16AWG-UOBKE-03 48 70.488 038. 178 20 0 on 01063 _0124-61C14AWG-U0BKE.03 61 7yo.aee 038 1e 249 ane Bee | oer ESC oe ra a a Diameter | thiekness | thekness ‘op. | Wolah ‘ue |e. KeXmn | nm mm om | Kas 010$4 0124-02G14aWG-UORKA-03 2 7x0.15 0.38 1.01 77 8 01065 0124-03C14aWG-UOBKE-03 3 20815038 101 al 19 01066 0124-oac 14awe-LoBKe-03 4 7x0.615 038 Lo. a8 a5 01067 0124-0sc14aWE-U0BK03 5 7x0815 038 Lot 36176 01068 0124-06¢ 14aWG-oBKe.03 6 7x0.615 038 127 ua (01069 0124-07C14AW6-U0BK8-09 7 7K0815 038, 127 ni 01070 0124-08C14aW6-U0BKe-03 8 7x0615 038 127 120 260 01071 0124-09C14AWE-U0BKE03 70615 0.38, 127 e293 01072 0124-10C244WG-U0BKA-03 10 7x0.615 0.38 127 Be a4 01073. 0124-12C14aWG-U0BKE.03 «12 7x0615 0.38, 127 143363 01074 o124-15C14aWE-U0BKA-03 15, 70615 0.38 152 16246 01075 o124-16C24aWG-U08KE03 16 7x0618 028 12 162486 0107 o124-19C14AWG-JOBKE-03 19 7x0015 0.38 ase v0 555 01077 0124-20C14AWG-UOBKE-03 20 7x0.615 038 152 79590 01078 0124-240 14AWG-UOBKA-0S 24 7x0.615 0338 152 ree 695 01079 0124-25C14aWE-UOBKE-03 25, 7X061S 038, 152, we 01080 0124-27C14AWG-U0BKA-03 27 7x0815 0.38 1s2 202 765 01081 0124-30C14AWG-UOBKE-03 30 7x0.615 038 132 209 838 01082 o124-s7c14awe-UoBKe-03 37 7x0615 038 178 23.0 1039 floes ol24-aRclaAwe-Uoakeo3 48 7X0615 038 a7 22 1321 01084 _0124-61C14AWG-UOBKA03 6 7x0.615 0.38 172 zea 1632 Sin MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) XLPE INSULATED MULTICONDUCTOR SHIELDED CABLES Temperature range - 40°C to +90°C Specifications: UL13 ES = TNSTRUMENTATION TYPE PLTC (UL) 200 MESC 2010, ‘Application : © Conductor © Insulation © Shielding © Jacket Industral signalling and process control cirvit in dry or wet locations. The cable can be used in cable trays conduit or direct burial application. Tinned copper to ASTM 833, stranded to Class B of ASTM 68. Flame retardant XLPE to [CEA $-82-552. Insulated cores are cabled and shielded with aluminium polyester tape for 100% coverage with a tinned copper drain wire. Extruded black PVC as per UL13, cil and sunlight resistant ‘passes flame test as per IEEE - 383 ( 70000 BTU ). The jacket is impervious to vapour and moisture penetration, Colour Code Conductor No. Colour 1 Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request Sn MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) XLPE INSULATED MULTICONDUCTOR SHIELDED CABLES Se | oer WESC cae Condens | Svands X | tralalin | Nowiat Jace | Armor | Apron Diameter | thickness | hikers | 0.0. | Wht owwea| sok ‘on ‘= swm_| Kalk D200 0254-070 70AWG-UOBKE-OS 2 _7x0.307 0.38 O87 5a a ‘02002 0724-03¢20AWG-U0BKE.03 «3 x0307 0.38 89 6183 02003 0224-04C20AWG-UOBK8.03 4 = 7x0.307 0.38 0.89 6s 60 (02004 0724-05C20AWG-UOBK8.03 5S 780.307 0.38 101 74 1% 02005 0224-06C20AWG-UOBKR.O3 = x0.307 O38 LoL 79 83 02006 0724-07020AWG-UOBKBOS. 7 x0307 0.38 101 7985 92007 0224-08620AWG-UOBKe-03 8 = 730.307 0.38, 101 B58 ‘02008 0724-09C20AWG-UOBKBO3 «9 7x0307 0.38 Lor 90 109 02009 0724-10C20AWG-UOBKE.03 10.40.3078 io. 97 16 2 ORB 0224-120 20ANG-UOBKRO3 120307038 127 105144 02011 0224-15C20AWG-U0BKB.03 15 80.3070.38 127 us 3 02012 0224-16C20AWG-U0BKB03. 16 7K0307 0.38 127 us 180 92013 0224-19620AWG-UOBKE-03 1970.37 0.38, 127 120 201 02014 0224-20C20AWG-U0BK803. 20, 70.307 0.38 127 6214 2015 0224-24C20AWG-UOBKB.03 24 7x0.307 O38 127 Le 208 2016 0224-250 20AWG-U0BKEO3 25 7x0307 038 127 be 238 02017 0224-276 20AWG-UOBKB.03 2777x0307 0.38 327 wi 270 o01k 0224-30C20AWG-UOBKADS 307030738 ar us 202 02019 0224.37C20AWG-UOBKB.O3 37, TH0.307 0.38 152 11 367 02020 0724-489020AWG-UOBKBO3. 4870307 0.38 152 Bl 455 ogo2i _0224.61620AN/G-U0BKE.03 6170307038, 152 19.7559 ca | oar WESC Cae Tondatans | Sands X | ttaln | Noni loaet | Aowoe | Aeron Dianeter | thine | ddoes | 0-0. | Wen awe} Ne. oka me = tome | Kalk ‘02072 OPP VACTBANG-UBKE OS? __7¥0.386 0.36 089 oe 02023 0224-030 18AWG-UOBK8.03. 370.386 0.38 089 er 8 02024 0224-040 18AWG-UOBKB.03 4 7X0.386 0.38 LoL 74 ot 02025 0224-05C18AWG-UOBK8O3 557X386 O38 101 Bo 9% 92026 0224.06C1@AWG-UOBKE-03 = & «== TXD.36 O38 LoL a6 106. 02027 0224-070 18AWG-UOBKB-03. «7 7X0.386 0.38 Yor a6 mL 02028 0224.08C1BAWG-UOBKS-05 8 = 7X0.386 0.38, LoL 93128 (02029 0224-09C18AWG-UOBK8-03. 970.388 0.38 a7 oa 157 02030 0224-10C1BAWG-UOBKS-03 10S 7X0.386 = 0.38, 127 12168. 1a 02031 0224-12C1BAWG-U0BKe-03 12, 7K0.386 0.38, azar us 189 02032 0224-15C1BAWG-UOBKE-03 15. 7X0.386 0.38. 127 26 228 02033 0724-16C18AWG-UOBKB03 16 70.386 0.38 127 Re 239 02034 0724-19C 19AWG-UOBKE-03 «19S 70.386 0.38 127 12270 02035 0724.20C18AWG-UOBKAOS 207X036 38 127 13928 02038 0724-240 18AWG-UOBKG.03 24 7X0.386 0.38 127 2 333 02037 0224-25C 18AWG-UOBKB-03 25. 7X0.386 0.38 127 152343 02038 0724-270 18AWG-UOBKE-03 27, 7XO.386 0.38 152 16.0383 02039 0224:30C18AWG-UOBKBO3 307X036 0.38 as 166 at 02090 9224-370 18AWG-UOBK8.03 37 7K0.306 0.38 152 78 500 02001 0724-4NC1RAWG-UOBKRO3 = 487X036 0.38 152 201 626 02042 _0924.s1¢}2AWG.UOBKs. a pane 0.38 152 Pig 768 4S MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) XLPE INSULATED MULTICONDUCTOR SHIELDED CABLES See] ter ESC Cade oatacon] Svante x | Tmulalon | Nonimalaacret | Appeoe | Approx ‘lamer | thickeess | thcnese 0. | Wei cawer | no. wo.Xmn | em mm sm | Kash 02083 0724-20 IGAWG-UOBKE-O3 2 70.488 0.38 089 6s 7a (02084 0224-03C16AWG-U0BKE-0s «3 7XOMOR 8 101 7b 88 02085 0224-04C16AWG-UOBK8-03 4 = 7X048B 0.38, x0. a1 107 (02046 0224-05C.16aWG-UOBKB-03. 5 7K0AB8 0.38 101 Ba 128 02087 0224-06C.16AWG-UOBKE-02 «== 7K0.488 0,38 1.01 95 ae o20aa 0228-070 6AWG-U0BKE-03. 7 7K0.488 0.38 aon 95 1st 02089 0224-08C 16AWG-UOBKS-05. «B= 7KO.4B9 0.38 27 roe 187 (02050 0224-09C.16AWG-U0BKE-3. «9 7K0.488 0.38 327 us oan 02031 0224-20C 16AWS-UOBKE-3. 107X048 0.38 327 wa 225 16 02052 0224-12G18AWG-UOBKE-03 12, 7X0.488 0.38, 327 327255 02083 0224-15C 16AWG-UOBKB-03. 15. 7K0.488 0.38 127 vo 2 (02084 0224-16C16AWG-U0BKE-03 16 7K0.488 0.38 327 149328 02055 0226-29C16AWG-UOEK8-0319—7X0.488 0.38, 127 147374 (02056 0224-20C16AWG-UOBKE-3 207X048 0.38 152 10 ane 02057 0224-240 16AWG-UOBKE-03 24 = 7X0.488 «0.38 152 a75 488 (02058 0228-25C16AWG-U0BKE-03 25 7K0.488 0.38 asa ws 499 02089 0224-27C16AWG-UOBKE-03 27 7K0.488 0.38 152 79533 (02060 0724-30016AWG-UOBKE-03 «30 7K0.488 0.38 ase aes 583 02061 0224-370 16AWG-UOBKE-03 377X489 0.38 as 199699 (02062 0224-480 16AWWG-UOBKB-03 487X048 0.38 178 21 92 02063 _O224-61C GAWG-UOBKA-03_61_—7K0.488 0.38 aa 250 19 Ta oer WESC tale ‘andation|] — Grande X | Taster | Nominal saaket | Approx] Row iameter | thickness | tikes: 0. | weak awe) | ne maxon | sm = sm Kin ‘2064 0224-20 TAAWG-UOEKEOS 2 __7K0s15 0.38 Tar &0 108 (02065 0224-08C14AWG-U0BKE-O3 «3 7KOKIS 0.38 Lo a4 a6 02066 02248-04C.14AWG-UOBKE-O3 47X05 038 1.01 oa us 02087 0224-0scadaWG-UoBKe-03 5 7K015 0.38 a2 04 02068 0224.06C14AWG-UOBKE-03. 6 «= 7KO.61S O38 127 n2 as (02069 0224-070.14AWG-UOBKE-O3 «7 =—7K0KI5 038 327 n2 02070 0224-08C 14AWG-UOBKE-03. B= 7KO619. 038 127 WI 260 (02071 0224-09C14AWG-UOBKB-03. «9 7KOKIS 0.38 327 229284 02072 0226-20C 14AWG-UOBKE-3. 107X815. 038 327 B33 14 02073 0224-12614AWG-UOBKE-03 127X045 0.38, 427 a4 364 02074 o224-15C14AWG-UOBKE-O3 157X065 038 152 emer) 02075 O226-16C4AWG-UOBKEYS 16 7XOKIS 0.38 152 3487 0207 0224-190 14AWG-UOBKB-03 197X015 0.38 152 556 (02077 0224-20C4AWG-UOBKE-03 20 -7KOSIS 0.38 152 eo 590 02078 0224-24C14AWG-UOBKB-O3 24 7KOKIS 0.38 152 199696 (02079 0224-25C.14AWG-UOBKEO3 25 7KOKI5 0.38 ase a9 ne (02000 0224-270 4AWG-UOBKG-03 27 7KQ615. 0.38 use 203765 (02081 0224-30C4AWG-UOBKE-3. 307X015 0.38 152 20 Bao 02082 0224-370 14AWG-UOBKB-03 377X065 0.38 i738 231 1040 (02083 0224-48C14AWWG-U0BKE03 487X015 0.38 178 263 Asza 02084 _0226-b1C 4AWG-UOBKO-03 617X061 0.38 170 265 1633 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) PVC INSULATED MULTICONDUCTOR UNSHIELDED CABLES Temperature range - 40°C to +90°C Specifications: UL13 INSTRUMIENTATION TYPE PLTC (UL) 300V MESG 2010 ‘Application: Industrial signalling and process control circuit in dry or wet locations. The cable can be used in cable trays conduit or direct burial application. © Conductor Plain copper to ASTM B3, stranded to class B of ASTM BS. # Insulation Flame retardant PVC rated 90C as per ULI3. @ Assembly Insulated cores are cabled with suitable non-hygroscopic fillers and polyester binder if necessary. © Jacket Extruded black PVC as per UL13, oil and sunlight resistant, passes flame test as per IEEE - 383 ( 70000 BTU ). The jacket is impervious to vapour and moisture penetration, Colour Code Conductor No. Colour i Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request 4a MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) PVC INSULATED MULTICONDUCTOR UNSHIELDED CABLES a WESC Coe ensues | Svante x | Teanation | Nonial aac | Appx | Apron Diameter | thickness | thickness | 0.0. | ein cwwer | Wo nokem | nn rm roo |_ Kgs Di08s O11 02CZ0AWG-UOBKE-OS 2 __7X0.307 0.38 0.89 se aS 01086 0111-03¢20AWG-U0BKs-03 = 3 7X0307 0.38, 089 sa 52 01087 0112-04¢20WG-U0BKE-03 © 4 = 70.307 0.38 089 63 (01068 0111-05¢20AWG-U0BKs-03 = «5 7X0307 038 089 6a 78 O111-o6cz0AWG-UOBKa-0s = 7KO.307 0.38 101 ye 89 01090 0111-07C20ANG-U0BKa-03 © 7 7X0.307 0.38 10 7a rom 0111-08¢20AWG-U0BKE-03 870307 0.38 101 ea 07 vlog o11-09¢20Awe-uoBKa-03 = «9 7X0307 0.38. Lo es 120 01093 o111-10¢20aWG-U0BKR-03 «1070307038 201 96 a7 2001094 «O1T1-12020WG-UoBKE-0s 12 7X0.307 0.38. 127 aoa 157 01095 0111-15C70AWG-U0BKE-03 15 -7X0307 0.38. 1277 na 189 01096 0111-16C20WG-U08KE-03 © 16 7X0307 0.38, 327 ma 497 01097 0111-19¢20WG-U0BKE-03 19 =—7X0307 0.38, 127 ag 222 1098 0111-20¢20AWG-U0BKe-03. 20 7X0.307, 127 25237 01099 0111-24C20AWG-U0BKE-03 24 7X0.307, 127 372A 01100 0111-25¢20AWG-U0BKe-03 25 7X0307 0.38 127 13728 101 0111-27C20AWG-UoBKe02 = 27, 7X0.307 0.38 227 140299 pi02 — o141-30¢20AWG-U0BKE-0s 30 7X0.307 0.38 x27 14a 324 01103 0111-37¢20aWG-UoBKE-03 37, 7xD307 0.38. asa 16.0 407 01104 0111-48C20AWG-U0BKE-03 48 7X0307 0.38, 152 380507 01105 __0111-61¢200WG-U0BKe03 61 __—7X0307__0.38 152 19.6 625 te] oar Wek cede Conaiaoes | Sana X | Tradation | Nomar awe Darter ‘ees Welt awe ome a Kn ‘OIT-GICTEAWE-UOEKEOS 270.380 Tay 35 0111-030 16AWG-UoaKs-03 3 7X0.386 089 o on-cécaeawG-UoBKaes 4 70.386 089 20 ‘O111-05C1BAWG-UOBKE-03 «5 «7X0.386 101 100 0112-06¢18aW6-U0BK9-03 8 7X0.386 101 ha ‘O1LL-O7CLBAWG-UOBKE-03 © -7——7X0.386 x01 120 O11L-0aC1eAWG-UoBKa03 = 8 7X0.386 201 140 111-096 18AWG-U0BK8-03 970.386 10 159 O111-20C1BAWG-U0BKA-03 —-10—7X0.386 1.27 im 18 O1L-12C18AWG-U0BKB-03. © «12—70.386 127 205 O111-15C1@AWG-U0BKB.03 «15 (70.386 127 27 O1L-16C28AWG-UOBKB-GS 16 7K0.386 0.38. a2 260 O112-29C28AWG-U0BKBO2 19 =—=—«7X0.386 038 127 295 112-206 1BAWE-UOBRE03 = 207X036 038 127 315 o112-24Ci8AWG-U0aKe-03 24 ——-70.386 0.38 127 360 O11L-25C28AWG-UOEKB-03 25 7X0.386 0.38. 27 375 0112-27C18AWG-U0BKB03 277X038 0.28 182 169 ale ONL-3OCISAWG-UOBKAOS 30 7X0.386— 0.38 152 65460 o112-37¢,8aWG-U0BKa-03 3770386038. ase a7 548 OLLAECIBAWG-UORKE-03 © 487X038 0.38 382 200 8a O111-61C18aWG-U0BKB-03 6170386 0.38 352 21748 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) PVC INSULATED MULTICONDUCTOR UNSHIELDED CABLES Se | baer WesCo ‘onto | Sands onal Jacket ‘pron Dianeter ‘beers ‘Weise cower] Wo a Ke on Kak Die? — IIPaeCIGAWG UODKE OS 270.488 387 7 1128 O111-03C26AWG-U0RKB0D «3 7X0.ABG 089 a 01129 O111-04C16AWE-UOBKEOs —@ 70.488. 101 no 01130 O111-05C16AWG-UDBKE03 57 x0.488. 101 13 01131 O111-06C28AWE-UOBKEOS —«&&=——7X0.4BB Lor 12 01132, O111-07C26AWG-UoBK8-03. 7 7x0.488. vor 162 01133 O111-08C16AWG-U0BKBO3 BS (70.488, 127 201 01134 O111-09C14AWG-UoBKB0s 9 7X0.488. 127 228 01135 O111-20C26AWG-UoBK8.03 1070-088. 127 2a 1 011360112220 14AWG-UOBKE03 © 127X0.488 1.27 24 01137 O11-ASCrGAWG-UoBKE0s —-15.(7x0.488 127 335 01138 O11-16C1bAWG-UoBKe-0s 16 ©=—7X0.488 Lz 353 01139 O111-29C16AWG-UoBKeOs 1970-488, 12 08 01140 0112-20C16AWG-U0BKe-D2 2070.48, a2 a2 1141 0112-24C26AWG-U0BKEOS 2470.48. 152 522 01142, O111-25¢16AWG-UOBK8-03 25. (7X0.488. asa 538 01143 O111-27C16nWG-UoBKB03 —27)-——7X0.488. 152 576 01144 O111-30C26AWG-U0BKE-03 30 7X0.488. usa 630 1145 O111-37C26AWE-UOBKeOs —-37-—=—7X0.488. 152 758 01146 O111-48C16AWE-UoBKe-03 48 7X0.488. 178 988 O17 OLLL-GICIEAWG-UORKEO? 61 _—7X0.488. ae. a7 ‘See | eer ERC toae ‘onions | Suande X | Toslaion ] Normal Jacket | Approx | Approx Diameter | theiness |" ihemres | "O.D. | Weiste cower] Wo. raxmm | mm on mo _| Keston ‘i1as O11T-02C14AWG-UOBKEGS 2 7K0.615_ 0.51 1.01 821 1149 O411-03C24AWG-UoBKE0s = «37X05 OST 101 a7 43? 01150 O111-04C14AWG-UOBKEOS —@=—7X0.615 OSI 1.01 9.4 168 o151—OLIT-05CI4AWG-UOBKeOS = 5S 7X0.615 OST 127 ros 25 onis2 O111-06C14AWG-U0BKEOS «== 7KO-GIS OST 427 ns 243 01153 O111-07C24AWG-U0BKBO3 7 7X0.615. OSI a7 ns 259 1154 —0111-08C14AWG-UOBKe-Os ©—«&@ == 7X0.815 0.5 127 ws 30 01155 O111-09C14AWG-U0BKBOs «9 7K0.615. OSI a2 Bz 340 01156 —O111-20C24AWG-U0BKE-OS «10S 70.815 0.51 127 149360 14 01157, ON1-A2CIAAWG-U0BKE-03 «2 7KOHIS OST 127 5300s 0118 O1LD-ISCI4AWG-UOBKAGS —15_—7XOGIS OST. 1s2 va 528 01159 O112-26C14AWG-U0BKB-O3 18 7KO.615 OST 12 74586 01160 O111-29C24AWG-UOBKe-0S 1970.85 OST 1.32 183038 onlé1 —0111-20C14AWG-UoBKB-Os 207X085. OS 152, 203681 1162 O110-24C14AWG-U0BKE-OD 287X015. OST 1's2 213796 01163 O111-25C14AWG-U0BKBOS 25. 7KOGIS OST asa 23 bee nla —O111-27C14AWG-U0BKE-03 27 7KO.EIS OSL 182 218 880 ON1G5 O11 S0CAAAWG-U0BKB-OS 30, 7X0615 5. 178 Bl 987 1166 O111-37C14AWG-U0BKEOS «377X015 OST 178 248 1296 O16? O111-48C24AWG-UoBKE-03 4B PKOGIS OST 178 2831525 116s O1NL-61CLAAWG-UOBKR-CS ol 7KOGIS SL 78. 308 1800 10 Siw MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) PVC INSULATED MULTICONDUCTOR SHIELDED CABLES Temperature range - 40°C to +90°C Specifications: UL13 S| TWSTRUMENTATION TYPE PLTG (UL) 2000 MESC 2010 Application : Industrial signalling and process control circuit in dry or wet locations. The cable can be used in cable trays, conduit or direct ourial application © Conductor Plain copper to ASTM B3, stranded to class B of ASTM BB. © Insulation Flame retardant PVC rated 90°C as per ULL3. © Shielding Insulated cores are cabled and shielded with aluminium polyester tape for 100% coverage with a tinned copper drain wire, © Jacket Extruded black PVC as per UL23, oil and sunlight resistant, passes flame test as per IEEE - 383 ( 70000 BTU ).The jacket is impervious to vapour and maisture penetration, Colour Code Conductor No. Colour 1 Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request Sn MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) PVC INSULATED MULTICONDUCTOR SHIELDED CABLES sae [Orr ESC Cade Cardicors | wands X | Inaiation | Noval seeks | Approx] Aoprox Diameter | ewes | thldwes | 0-0.” | Welt ol es orm | mm am vm | Ka/Kon ‘2085 OFT 2CZ0AWG UOBKEOS 2 7x0.307- 0.38 087 59 50 (02086 0211-03C20AWG-U0BK8-03 3 7x0.307 0.38 089 e157 02087 0211-0aC20aWG-UoBKe-Os 4 = 740.307 0.38. 089 6s 64 92088 a211-05C20AWG-U0BKSOS = 5 7x0.307 0.38 1.01 74 Bt 02089 0711-06C70AWG-U0BKA03 740.307 0.38 10 7988 (02090 0211-07C20aWG-U0BKG03 «7740307038. 101 7993 02091 0212-08C20AWG-UOBKE03 = 8740.07 0.28. Lor as 107 (02092 0211-09C20AWS-U0BKB03. «9 740.307 0.38. Lon 90 12 02093 0211-10C20AWG-U0BKB03 10 740.307 0.38. 101 97 Rr 20 02094 ozIA-12CZ0AWG-UOBKBOS 127x007 0.38 a27 105157 02095 0221-15C20AWG-U0BKS03 157x007 0.38, 127 15 190 902096 0211-16C20AWS-U0BK803 16 740.307 0.38. 127 m5 198 02097 0211-19C20aWG-UoBKs-03 19740307038, 127 wo 22 2098 0211-20C20aWG-UORKB03 20 740.307 0.28 a27 26 237 02099 0211-24C20AWG-UOBKB0S 24 740.307 038. 127 we 274 92100 0211-25C20AWG-UOBKS-03. 25 7x0.307 0.38. 127 138 282 2101 0232-27C20AWG-U0BKB.Os 27 740.307 0.38 127 141300 2102 0211-30C20AWG-U0BK803 30,740.07 0.38 127 145325 92103 0211-37C20WG-U0BKa03 37 7x0.307 038 152 yer 408 02104 0211-48C20AWE-UOBKS03 48 740.307 0.38 152 11508 02105 0212-616 20AWG-U0BKB03 61740307 0.38 152 197626 se] Over ESC Coos Condictors | Swanas X | Tesuaion | Nominal seeker | Approx | Rowan ‘Dlameter | chmes | "thse | “0-0. | eign awn | no. mexnm | mm vm mm | Kg ‘zics OFT-OACTEANG-UGKEDS 2 7K0.38e 0.38 089 o & on107o211-03C1eAWG-UCBKAOS = 3 7K0386 038. 89 6773 02108 0211-0€C 19AWG-UGEKB-03 = 7KO386 0.38. 101 74 6 02209 O2NT-OSC1BAWG-UBKB-03 «570.386 038 101 80 103 02110 0211-06C18AWG-UBKB-03 © ~—«7K0.386 0.38 10 a6 ne 2111 0211-07C18AWG-U@BKAOs—«7——«7X0386 0.38 Loi ab aan 02112 0231-08C 18AWG-UGBKA-03 BS 7KO386 0.38, ro1 93 140 2113 O211-09C18AWG-UBKEOS «9 7X0.386 0.38 127 aoa a2 2114 0211-10C18AWG-UBKB03 10S 7K0.386 0.38. 127 nen 182115 oaINCIBAWG-UCRKADS 12, 7KO386 0.38, 127 5205 02116 O211-1SCIBAWG-UGKE03 15 —7K0386 038. 127 26 oe 02117 O211-16C1BAWG-UCBKBOS 16 7X0386 0.38 427 126 260 o2iie —o22-19C18AWE-UBKaOs 197X038 0.38, 127 2285 o2i19 0211-200 18AWG-UBKB03 20, 7K0.386 0.38. 127 139 316 92120 0211-2C 18AWE-UGBKAOS 24 ——7K0386 0.38 327 asa 365, 02121 o211-25C1RAWG-UcaKe03 25 7K0.386 038 127 152376 92122 0211-27C12AWG-UOBK803 2770386 0.38 152 10 419 02123 0211-$0C18AWG-UBKBOS 30 7KO386 0.38, 182 165 460 2124 02)1-37C18AWG-U KBs 377X036 0.38 152 ve 549 02:25 O212-4BCIBAWG-UCBKBOS 4B 7X0386 028 as2 201 689 02126 0211-610 18AWG-UGBKS.05__61__—7X0386 0.38. 152 zie ee 12 Sun MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS TYPE PLTC (UL) PVC INSULATED MULTICONDUCTOR SHIELDED CABLES Se | tae Wea Cate Conmicions | Svands X ] Tnsaion | Nowialocket | Approx | Aoprox Diameter | thickness | thckess O. | Welat wor] wo raxmm | mm ‘mn mm | Keston (217? GaT-02CISAWG-UOBKEOS 2 _7X0-488 0.38 089 69 77 02128 G211-03616AWG-UOBKE-03 «37X04 0.38 101 7 9 02129 0211-086 146AWG-UOBKE-03 4 = 7X0.488 0.38 Lor al us 02130 0211-05C16AWG-UOBKE-03 = 57X04 0.38 101 ee 136 02131 0211 06C16AWE-UOBKE-03 «&&©=—7KO.4BB 0.38 101 9s 152 (02132 G211-07C16AWG-UOBKs-.03 © 7 7K0488 0.38 x01 95 162 02133 O21L-08C16AWG-UOBKE-03 = B= 7X0.ABB 0.38 27 308 202 2134 G2i1-09G1sAWG-UOBKS-03 = 9 7X0.4B8 0.38 127 m5 29 02135 G2U1-10C16AWG-UOBKe-03 © «1d-—=S7K0.ABR 0.38 127 wa 2a 16 02136 OR11-12ELSAWG-UOBKEOs 12 7KO.MBB 0.38 137 7S 02137 G211-15C14AWG-UOBKE-03 157x048 0.38 427 Mo 336 02138 G211-16C16AWG-UOBKS-03 167X048 0.38 127 Mo 384 02139 0211-19C16AWG-UOBKE-03 197X048 038 127 147405 (02140 0211-20016AWG-UOBKE-03 «207X048 0.38 usa 0452 2141 0211-240 6AWGE-UOBKE-03 247X048 0.38 ase ws 523 02142 G211-25C16AWG-UOBKE-03 25 7K0-488 0.38 152 5539 02143 0211-27C14AWG-UOBKS-03 27,—=7K0.488 0.38 sz v9 576 02144 o211-30C16AWG-UOBKE-03. 307X048 0.38 152 aes 63 02145 o211-37C16AWG-UOBKE-03 37 7K0.488 0.38 ase 199758 02146 0211-480 16AWG-UOBKS-03 487X048 0.38 178 23.1989 2147 __O211-6ICTOAWGE-UOBKE-O3 70.408 0.38 178 25.9 1218 Be | baw ESCO Condi | Seartk X | aon | Monat loa | Apwon | Ape Diameter | thickness | tickess 0. | Weis aie) | No roteon | "na ma fom | avn Q2ide GaroRCIaAWG-UOBKEOS 2 7X01 OT Tor 85 ule (02149 G211-03¢14AWG-UOBKE03. 3 7KGHI5. O81 101 9044s 02150 G21-06C14AWG-UOBKe-03 —«&~=—=7XOKIS OST xor 97 169 2151 0211-05C14AWG-UOBKE-03 = «5 7KOGIS. OSL aa Ma ae 02152 G211-06C14AWG-UORKE-03 «== 7KOBIS. OSL 327 129 2a (02183 0211-07614AWG-UOBKE-03. = 7 7X0815 O81 327 120260 0214 G211-08C14AWG-UOBKE-03 = «8 == 7XOKIS OSL 1.27 130 302 02185 0211-09614AWG-UOBKE-03 © «997X015. 327 we 3a 02136 0211 10C14AWG-UOBKe-o? 10 = 7KOKIS OSL 127 15.0 3h a4 02157 0211-12G14AWG-UOBKE-03 12, 7KOBIS OBL 127 4 a 02152 0211-15C14AWG-UOBKE-03 «15. 7KOGIS. OST ase vs 329 02189 G211-16C14AWG-UOBKE-03 «= 167X061 use ws 587 02160 G211-19C14AWG-UOBKE-03 © 19.=S7KOKIS OSL 152 ea 639 2161 0211-20014AWG-UOBKE-03 © 20.=7KOIS 051 ase 198 682 02162 0211-28C14AWG-UOBKE-03 24 = 7K015 OSL ase 24797 2163 0212-25C14AWG-UOBKE-03 «25 7KOKIS O81 152 2a 823 02164 —G211-27C14AWG-UOHKE-03 © 27«—=S7XOKIS. OST 152 219 eal 02165 O211-30C14AWG-UOBKE-03 307X065. 0.51 178 23.2998 02166 G211-37C14AWG-UOBKE-03 377X015 OSL 178 249 nna? 02167 0211-40C14AWG-UOBKE-03 = 487X015 OSL 17a zea 1524 2168 _G211-61C14AWE-UORKE-O3 —_62_—7KOBIS 0-5). 178 309 1891 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED Temperature range - 40°C to +90°C Specifications: UL13 TWSTRUMENTATIONTYPE PLTG (UL) 300 MESG 7010 Application : Can be used ia cable tray, conduit or direct burial application for instrumentation / ‘process contra, in dry or wet location, © Conductor Tinned copper to ASTM B33 & stranded to Class B / Class C of ASTM BB. @ Insulation Flame retardant XLPE to [CEA $-82-552. Pair Colour Code White and black with pair number on white conductor. © Triple Colour Code White, black and red with triple nurber on white conductor, © Pairs/Triples Twisting All pairs / triples are twisted to counter electromagnetic noise. © Assembly ‘Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary and the entire assembly is covered with a polyester tape if required. e Jacket : Extruded black PVC as per UL13, oll and sunlight resistant, passes flame test as per [EEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration. 14 nN 4S wn MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED PAIRS SHE oer ESC Code Pas | Suan Nominal iacet Aparon. | Aprox ameter tices | 0.0. | weight co) i. No.X mm oo mt] akon binee __oigaviPiAwe-voeKeos——a_—~7 x08 30 «2 * 18 m6 ae 70506 132 ms ats ours 2 Tko3ee 178 Br as one Se Tkose8 18 ass tiie szesopinawe-UoeKens 3070368 253 so ize SHE eter ESC Cove Pairs | SwandsX | twnfaton | Nomiaallacet [Aporot. | Approx ameter | thicaess | thidmess | 0.0. | welaht 1aw) No. eran _| nm om com_| Karke Tie) _oigeOIPIGAWG-UOBKEG? 1 ~~ 0a O89 ee wo bina eeoauawG-UoBKos = 4 7kanea 38 un mas suey ouzeogrisawe-UooKeas «7x38 ar B22 cn86—OizeowPleAWG-UOBKBOs 8 7xDaee Oa ase ess * sits oLzes6PieaWG-UOBKEGS = Ye 7XOMBe a8 1s as wo oiise—olneaarieawG-UoBKe-0s 28 7xDae 1 re 5 cnissoieeszpieawe-voBK@-0s 52 7xam O38 18 jor ats cigs onaeaorinawe-uoBKa-os ao 7xeen 38 20 Dr we s126 _onzesorrese-UabKeas 507X838 203 371175 SRE oer WESC Code Pairs | SkandeX | tration | Nominal locket [Arorox. | Approx diameter | thickness | thickness | 0.0. | weight awa) No Nom | ro mm mm_|_ Karke tne _aeaipaweuveeos 1 9x0373___ast 19 ee nize & texans oa ase tes eo “ 204 1 axos7s ast 18 we ore oizde —cheezaPiaAWGUaBKG-OS 249X079 ast 233 Bs we pup sizer eawe-ube 49__asxou7s 1 2 43 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED TRIPLES. SE ESE cose “Wie, | SwandsX | soar] Worinal chet] Anwar. | Aron fareter | tiekness | wetness | 00. | welt 13) No. Xm oo om om _| Kan TRF aTTIOAN WORE OS 17x a3 038 Tor 3S = ‘oxgeazTeAWG.vOBKBA3 2k 0386 038 a 26 as ‘124087 8A VOKKE.OD 47% 0386 038 127 aa 195 ‘oat anT saws-voaKed 8x a386 38 se pr 300 ie ‘ze 2TBAWG VOBKB 3 2 7xa386 038 132 208 495 aR LETINAWG-VOBKEOD we 7x98 038 we aaa 8 (0124207 86W6-VOBKB 03 2 75306 038 178 264 15 ‘onze zeTaw-voBKs-23 7K a2Hb 038 178 286 35 (024367 1HAWG-UOBKBO3 hae 338 203 26 1365 12 AST AWGYOBKEOS as 7x03 038 208 393 760 SHE, WESC Coe ‘Wines | SuantsX | Ioslnion | Nominal eter | Approx | Arran ameter | thicness | nines | 00. | weiake awe No. X mm om wn mm _| Kok ‘orzeazT AWG, UoBKS.03 2 7xene 38 17 a9 165 ‘oR 087 6AWG-WOBKS.03 4 7x86 038 437 389 285 ‘12+ o6r 6AWG-VOBKE-3 6 7xo486 038 ise 187 30 ‘ona aHT6AWG-VOBKEOS 8 xed 038 132 a8 490 ‘onze serisawe-voaKecs xe 7x48 038 178 2a 320 [0124207 6AWG-VOBKE 03 2 7 x040s 038 178 238 ms ‘BL Ser BANG-UORKBOS 3h 7 xan 038 20 * 130 sae] Order ESE Goce ‘Wine | SandsX | tension | Wowhaljacet | Approx | Appax ameter | titres | iniemess | 0.0. | weiahe exwey | _No. So. X mm om som _| Karem i237 or24 9372 4AWG-UOBKS.G3 > 19x0373 os ise m3 535 122 or24T:4AiNG-UOBKS-03 8 xeon 178 289 765 ora onze 3672446 UOIKBOS xO ost 203 aaa 1440 err ou24 247 AAW YORK. 24 asto373 ost 20 oy a 16 Sion MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD OVERALL SHIELDED Temperature range - 40°C to +90°C Specifications: UL13 =< INSTRUMENTATION TYPE PLTG (UL) 300 MESC 2010 Application : Can be used in cable tray, conduit or direct burial application for instrumentation / process control, in dry oF wet location. © Conductor Insulation Pair Colour Code Triple Colour Code Pairs/Triples Twisting © Overall Shielding © Jacket Tinned copper to ASTM B33 & stranded to class B of ASTM BB Flame retardant XLPE to ICEA $-82-552 White and black with pair number on white conductor White, black and red with triple number on white conductor. All pairs / triples are twisted to counter electromagnetic noise Twisted pairs/ triples are cabled with non-hygroscopic filles if necessary and the entire assembly is shielded with atuminium polyester tape and a tinned copper drain wire Extruded black PVC as per UL13, oll and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD OVER-ALL SHIELDED PAIRS. Size rae MESO Code Pars] Strands X | nsolation —] Nominal ovet ‘diameter | thickness | thickness (awe) No. No. X man mn on ware GUO 4 7X03 038 137 oar HG UDB | . 7x03 a8 aan oa80 iG UOBKE-9 | 8 20s 038 138 9218) oz240PTBAWG-UDEKE-03 ° 7x00 038 178 On182 __02249PIRAWG-UOBKE-OD 20 7x03 038 13. SIE ‘rer MESO Code Pairs | Swans X | tnsulation | Nominal acket ciameter | thickness | thickness 136) No. No.X me i nt “ aai%e 6 7x0 038 1s ona 3 Deas 038 178 anise 38 down 038 203 42196 0224 50PT6AWE-UOBKE-OS 50. 7x08 036 203 TRIPLES, SE er WESC Code Woles | Strand X | Inwvlalion | Nominal jacket | Approx | Approx ‘ameter | thickness | wickne’s | 0.0. | weight cower Wo. No. X nom ‘an me om ealey bree oTTaRAE URES T 7Kosae 038 009 vb 8 ozaes case 2071846. uowKEa> 2 a3 638 178 25 70 mor axze.s7Ta8AN6-UooKEas a 7xo386 998 203 53a zt0 ‘SIE ‘rae MESC Code "Winles | Swans X ] Tastlalioe | Nominal jacket | Agorox. | Approx ‘tometer | thickness] thickness | 0.0. | Weight «awe No. ‘No. rn on mm smm_| Kg “aan aa}eOITIOAWEVOBKTOS T 7x0s68 038 xr 758s eae 2 Roa O38 har mo 170 ia 4 reas Oe aa 380s Geared axes Ti4awG vob 33 * Treas OR ase 3 ins % canis Saab aaTiaw-Uabea-3 w 7kow 038 17 who 221 Oa2e16TL6AWG-UDBKE-3 wo axes O38 178 22 ms 7 18 Sion MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED Temperature range - 40°C to +90°C Specifications : UL13 INSTRUMENTATION TYPE PETG (UL) 300V MESG 2030 Application: Gan be used in cable tray, conduit or civect burial application for instrumentation / process control, in dry oF wet location. © Conductor @ Insulation © Pair Colour Code © Triple Colour Code © Pairs/Triples Twisting © Individual and Overall Shielding © Jacket Tinned copper to ASTM 833 & stranded to class 8 of ASTM BB. Flame retardant XLPE to ICEA $-82-552 White and black with pair number on white conductor. White, black and red with triple number on white conductor. All pairs / triples are twisted to counter electromagnetic noise, Each pair / triple is shielded with aluminium polyester tape and a tinned copper drain wire for maximum electrostatic noise and crosstalk rejection. All pair/triple shields are electrically isolated from each other. Individually shielded pairsitriples cabled with non-hygroscopic fillers if necessary and the entire assembly is sheilded with aluminium polyester tape and a tinned copper drain wire, Extruded black PVC as per UL13, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) XLPE INSULATED MULTI PAIR / MULTITRIAD INDIVIDUAL & OVERALL SHIELDED PAIRS wae] oar WERE Code Pars | SiranisX | ravation | Nowinaliacket | Asprox | Aver ‘taneter | thidnes | tienes: vlan wae) |W. Noon | mm 04 ‘fae our teAWG-VOBKe-63 Sees oa war 20 8 rae s2Piaaws.Uosta 03 2 7xGsm Gan ise 80 oon Sezesepaaawevopea 8) Se hoses ose ae a0 sone Srze aoe saawevopKH as © Tkomee 038 ae 1250, SRE] Oder ESC code ars | Stans | sutton | Nomieatiacket | Asprox | Approx Gameter | thelwess | thine | 0D. | weight wawer | no. Hoxmm | “wm mm a oats orzeoppneawe. once a3 8 7xoe 038 1s? 7s 420 eas caze s2PteAWS-UOBKG-03 52 rena 2a Ra ws. 3s orev anpieawe-uoKe es Tena 3s ans 3700 TRIPLES SRE] Oe ESC Code Pars] Sivas] tnwaion ] Nominal jacket | Atprot, | Approx diameter | thknes | thlekness | 0.0. | weight awe) Noe _| nm pm] ade cane onze T1BAWG-UOBKEt3 kos ose 2a ss 3s SE] ow ESC Cade Pais Tasuatian | Noma ost os ‘ieiness | 0D, | weit vawer |W. mm som | Kash esse bizbasT26ANG LOBE a tae iar Ms 30 tet deasaorienns Dope ® o38 132 iy 0 stots SGezericawe-unpxeas » oe oe aso acer nezesaTi6AWs-UOB«e-03 2 O38 aos a2 ans. 19 20 4 iu Esc INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC) WIRE ARMOURED XLPE ISULATED MULTI PAIR/TRIAD OVERALL SHIELDED Temperature range: Specification: : ULI3 Ss 40°C to + 90°C TWSTRUMENTATION TYPE PLTC (UL) 360 MESC2030 Application Can be used in cable tray, conduit or aivect burial application for instrumentation / process Control, in ry or wet location. The wire armour provides longitudinal strength for use as a messenger cable or for suppor" in vertical drops (NEC SECTION 300-19 } and provides the protection against the mechanical damage Construction Conductor Insulation Pair colour code Triple colour code Pairs/Triples Twisting Over-all shielding Inner Jacket Wire Armour Outer Jacket Tinned Copper to ASTM 833 & Stranded to class 8 of ASTM BB. Flame retardant XLPE to ICEA $-82-552. White & Black with pair number on white conductor. White, Black & Red with triple number on white conductor. All pairs / triples are twisted to counter electromagnetic noise, ‘Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary and the entire assembly is shielded with aluminium polyester tape and a tinned copper drain wire. Extruded black PVC as per UL23 AA serving of round galvanised steel wires is applied with 90% minimum coverage. Extruded black PVC as per UL13 is oil andsun light resistant and passes fiame test as per JEEE-383 (70000 BTU). Kuan MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC) WIRE ARMOURED XLPE INSULATED MULTI PAIR /TRIAD OVERALL SHIELDED PAIRS pe, ee ae ee | eS eel wo SE SHSPINENES SORE GR Ig I BI IB Sy 02625 0226-12PI8AWG-WOBKS3 12 740366 038 152 174 16 199 178 237 1025 2626 0224 6PLRAWGWOBKRO3 167x038 038 152 186 16 228 17a 28s 134) ‘2627 0224 20PLRAWG-WoRKRO3 20 7x0386 038 152 215 Le 247 178 28a 1512 82628 022424PIRAWGWOBKB.O3 24 70386 038 178 237 18 369-178 3071745 92429 0224 36PIRAWG-WOBKE-O3 36 _7x0386 O38 178 28220 3222033642477. aE | Oe ESE Pars] eaaeX | pan eaaor | Remar | Sar | Ga] Rear ‘omer | tines ‘ive ace] ah oe eo cae] no wos | nex | mn mo vom | rom | win 8b a7 11a 265 ae? 182 Jeo 658. Aas 7 1s2 209 eae 125 191 17 28 592 Mb 3178 25.1 1256 1b 27178 265 1390 T2630 GREEOIPIOAWEWOBKSGS 1 7x0489 0.58 ‘ota oa2enaPr6AWG.WORKe03 2 7x0489 08 ‘02632 O22404P16ANG-WORKEO3 4 7x048 038 02639 G26 06PL6AWG.WORKEO3.—& 7xO48e 038 02634 0226-08PLGANG-WOBKS03 8 740480 038 36 02635 GazeioPibaWG-wosKeas 10 740488 038 02636 072412 I6AWG.WORKE-Os 12 70488 0:38 a eee et eto TRIPLES sit pes) tee = Eee aE ES" =s= ee |e ee Pelle lie UE LE TE ce Sa ala :iiamiiemmiemidin hemi 7a 247 170 17 2631326 17% 279 146 qe O2e4s Ga24oeTIAAWG-WORKEDS 8 7xO38 098 152 1727 16 02646 C22420TIBAWG-WOBKE-03 107x026 0.38 182 194 16 O2ea7 ozzet2TieawG-WOsKe-03 12 70986 038 152 209 16 O2sda ozzeterieawG-woske-os 14 7x03 038 178 241 16 Lye HL ase Gage gp24z0rieawewoaKe-02 20 7x03 O38 L7R 26s Le 203 340 2600 D250 OReASATISAWG-WODKE-OS 24 70386 038 178 28) 2032.72.03 3492514 EE] Oe WERE oe aa cd “gar | Reese Y Dae | Cae ones | Sitees | Jodee tre” | “ie” | Sete |e] Rt Tet ‘bs | am | tex | 00 awe] ne. nies | Nexon | om] na Ton | nL xan 9265) G22eoiTToAWG WOBKe-O> 3¢ 1.01 0992 «(Nay 120 301 2652 G22es2TIeAWG-WOBKE-O3 a3¢ 127 7 2 125 184 152 187 4650 0265s G22eoerieaWe-WosKe-os 4 7x04a9 038 227 ‘ e320 9 389 e230 17a 2a 1398 16250178 a7 ses Me 23 17a 30 tee 1s 303 2a3 See 2190 20339203 31 2748 20 $e8 303 aa 3s Db6se GeassaTieawe.weekaas 6 Fx0daa O38 282 ag 02655 0224-0871 6AWG-WoBKe-03 70483 038 15e 02656 G2241OTIGAWG.WODKB.O3 107x048 038 152 2657 o2a4l2TIGAWG.WOOKE-03 12 7eaeBR 038178 aese az2eI6TIGAWG.WORKEOS 16 7xoMDe 038170 02659 0224 20714AWE-WoBKE-O3 207x048 053 278 0266002242471 GAWG.WOBKE-O3 247x088 058203 al fiw MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) WIRE ARMOURED XLPE INSULATED MULTI PAIR / MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED Temperature range - 40°C to +90°C Specifications: UL13 TWSTRUMENTATIONTYPE PLTC (UL) 300 MESC2030 Application : Can be used in cable tray, conduit or direct burial application for instrumentation / process control in ry or wet location. The wire armaur provides longitudinal strenath for use as a messenger cadle or for suppor in vertical drops (NEC SECTION 300-19 } and provides the protection against the mechanical damage Construction © Conductor Tinned Copper to ASTM 833 & Stranded to class B of ASTM 88. Insulation Flame retardant XLPE to ICEA $-82-552 Pair colour code White & Black with pair number on white conductor. Triple colour code White, Black & Red with triple number on white conductor. © Pairs/Triples Twisting: All pairs / triples are twisted to counter electromagnetic noise. © Individual and + Each pair / triple is shielded with aluminium polyester tape and a Overall Shielding tinned copper drain wire for maximum electrostatic noise and crosstalk rejection. All pairftriple shields are electrically isolated from each other, Individually shielded pairs/triples cabled with non-hygroscopic fillers if necessary and the entire assembly is sheilded with aluminium polyester tape and a tinned copper drain wire. © Inner Jacket Extruded black PVC as per ULI © Wire Armour A serving of round galvanised steel wires is applied with 90% minimum coverage. © Outer Jacket Extruded black PVC as per UL13 Is oll and sunlight resistant and passes flame test as per IEEE-383 (70000 BTU) 22 MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC) WIRE ARMOURED XLPE INSULATED MULTI PAIR/ TRIAD INDIVIDUAL & OVERALL SHIELDED PAIRS [se oer Paes] Scans | hon peo | Baie ] Sm | mee ESC cose tamer | wens: WEE | shat |“ | wei cower |. axen |" rn fom | Tron |_| want Din5d UHR GIPTEAWEWOBKROS F-70386 38 04259 O42e04PIBAWG-WOBKE-O3 4 720386 036 04260 oszecePiBAWE-WORKE-O3 6 720366 0.36 D426 OkzeasPieAWG.WOBKE.O3 8 7x08 038 04262 O424-10PIBAWG-WOBKE-03 19 740386 038 Tel Vat tas 409 134152167 Sah aes 152 201782 77 1se 2038 397178 334 10m a Se itt hatte 1 ar te st het ioe et sia ae ‘tn Sh pf a a a ca am a) Ree | ie | Sa | i fale ia [a0 ee ees ou sa a cy Se ee a ie TRIPLES aa oar S| vse [| PRR* Yite) Sk ]| ie | Meee | | Se | at as ew |S SE ee ae ee ee o Lae ee adele Sen sm is Se hee lar eee a ge eel ete ae a a a i aE a ra a ee | BR BT GR MESC Cote tress) ee | Sor Bee | thst | “es ee sxcesl oe Oe ee) | | SNR iio an a 42e.12TLeAWGWORKR-3 12 038 178 28218 BRA 200 72008 0826-16TIGAWG-NOSKE3 16 ose 17 265 20325203 3482803, 4 2OTIGAWG-WOSKGS 20 740480 038 172 S14 20 354-208 39.7 3053 eDATLGAWGMOSKSOS 24 7e04ss O38 203 ahh 70 386 203428 3510 24 Sun MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) PVC INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED Temperature range - 40°C to +90°C Specifications: UL13 INSTRUMENTATIONTYPE PLIC (UL) 300V MESC 2010 Application: Can be used in cable tray, conduit or direct burial application for instrumentation / process control, in dry or wet location. . Conductor Insulation Pair Colour Code Triple Colour Code © Pairs/Triples Twisting Assembly Jacket Plain copper to ASTM 83, stranded ta Class B / Class © of ASTM B8. Flame retardant PVC rated 90°C as per UL13. White and black with pair number on white conductor, White, black and red with triple number on white conductor. All pairs / triples twisted to counter electromagnetic noise. ‘Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary ‘and the entire assembly is covered with a polyester tape if required. Extruded black PVC as per ULJ3, il and sunlight resistant passes flame test as per [EEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration. INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) PVC INSULATED MULTIPAIR / MULTI TRIAD UNSHIELDED PAIRS aE | oer ESE oe Pais | SeanaX maaan | Nomar aoe aire omer | ticines | eines | “3D. | weit awe) | na, Neen e m_| Kohn 2287 a aOR TAT 17x00" 076 oa 37a eat orttoePepnwe-uieKe a 2 year a8 vo ao Sia Glsketesbawe-ugme 9) 2 eter 1 wie fue Shun aerzeawe-LooKe 93 pees ae Ge Bl Me ome ghnvaepzaawe-unoKe 3) fe 3x0s7 ose ve m2 as eis Suuasepsonwe- books 3} so Feeser ae oe ms sae | oar WESC Coe Pais | Sean Ten ie omeer | icine Gon | ei cower | na, woscmm | fom | a tse Stun otPieswe boBKe a oe ass) Sate natin mo ‘ om m3 Ho aie eiutaanianwe-uoera 05 s cae nr hs TE] oe WES coe Ta Tae Taare ‘mete ‘00. | ‘weatt awe | na, ‘sm frm | tote a TPP TORRE T oH Fr 7 or ois eLikoabueawo-voeKeas 2 oe Ly Mae aur 3 oma ay 22m e12e0 ‘ oe 1s ies Se oe austere asks 3} 2 oa ie tea 8 vase Bu Fkaeee Oa Oe me izes 3o kom ae ie moins oleae seein BESS a 5B BE a WEST tae Weal ake | Bee tae 33 | ‘ee awa | ne. ‘a ‘oo fem_|_ ain oie a ba ase use a Olas 5 231 as es ‘a binnaPranwe-dasknes Xe ast ae me oss cise onnaihianwe-ioncess B 28 aa as ss 26 Sin MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) PVC INSULATED MULTIPAIR / MULTI TRIAD UNSHIELDED TRIPLES SHE] one WESC cae a a dame | inaives | tnaaness | 0.0 | webht cower | _ we orXnm | om ‘on tam_| Keiko Gis0t 11 @iTzOAWG-UOEKeGD T—7x0307 036 as co #0 idee o1nt-o2T2eaw6-vaBKE-03 2 7x0007 a aay ws 308 03309 01118372046 UoBKE-@> > 7x0307 38 aay nas ioe O111-g4T20ANC-UBBKE-OD 4 9x03 8 az wa 160 2330s 0111. 06T20AWG-LOBKE-02 & 7x0x7 ae 127 we 20 i906 OL gar20AWG-UoBKa-a> 8 7x0307 038 aay ise 270 2003307 OULIARTROANG-UOBKBOs —-12=7XO307 938 ise 187400 isos LLL TGT2OANG.UORKeGS = 16703078 as aa to bio 9112020AWG-LOBKBEs «70S 7 X0307 38 378 as bo ei ouun2aT20ANG.UoBKRGD = 37X00 a8 ie 2s as fia oltnarTzoawe-UoBKses 327X830) OB 178 fase a1oi2 GMT DeTRDAWGUOBKEOS = 36703078 ae jon 1860 Osis ollLasT20AWG-UebKSeS ae 70307038, 203 wo 08 SHE | ose ESE oe oles | SwandsX | tnslion | Wonial ake Toa diameter | Oieires | "anes ‘went cower | am ‘on are, isi _oiineiTieawG-uoBKe-03 T7x03% 038 099 a minis ouusezTiaAwe-UoaKe-e3 2 7Xos8 ae aa 235 fing onisasTieAwe-uoBKe-c> > 7x03% 038 12 0 O17 eLLyoeTIRAWG-UaBKE-09 4 7X0386 ae aay no piste @lY-oeTtaaWe-UobKe-03 & 7x03 ae asa ne ume oLL-oeTueawo-voBKs-03 ® 038 ase 390 1021 OLNNLGTIBAWG-UOBKEO) 16 36 17 ns misay ouur2erisawG-UoBKeOS 24 038 ae 1025 Sa] ber Teton | Nowinal eke “Toor ‘oitwes | iin ‘ent scawer | ma ‘m on Karke ais27_ ous eiTieawG-uo8Ke-0> 236 1er a aise O11. ¢2T16AWG-UoBKE-03 O38 aar x70 aise) ouurasTisawe-uonke-a3 oat aay 2s (01530 GLIT-o¢Ts6AWG-UOBKE-03 O38 aa 20 asa oun aeTigawe-uoBKe-o3 O38 as 20 giase anit oerieawe UaBKE-03 O38 ase 5 16 01333 omnraaTieaw-uos oat 178 ms ois OMN-teTT6ANG-UoB) 038 18 995, bss o1us-20Fieawe-UoaKa-e3 oat Le mie aiss6 mn 2aT6AWG-LoRKS-0s 03 203 1460 1337 oun a2Tieawe-UoaKa.c3 oat 203 1880 191338 OLA 26T14AWG.UOBKE.08 O38 203 2098 SE] owe ese ae Tioaien | Newest nae Toor (wetness |" thexnes ‘wea es om es Koren T1339 SrILaiTaeAWG-UOBKG-Ds T vexoss ost 302 120 LMo O11 aTIaAWG-UoBKA-03 2 laxoa73 ast aa 270 o1gs2__ on1eprreawe-uonke.03 > 19x0s73 as 452 373385 onda gnT-o¢Ta4awG-UoKKa-03 4 a9xes73 ast 152 ea aes re 143 OL FogTIAAWE-LOBKE-s 6 axa as ye 2543s 1344 oniToaTI4aWe-UoBKe-63 8 19x08 GB ae oho B28 oisés —ouiazrisawe-Uoeke-0) 1219073. 178 26 ns 01346 oMLIeTi4AWG-UOBKE-O3 = «619X373. 203 Sha ses iss? onivzorneawe-ooke-05 = 20S «19X0373. ast 2.03 3781910 13g O11L2ATI4AWG-UOBKA-03 24190373051 203 4072245 fw. MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) PVC INSULATED MULTI PAIR / MULTI TRIAD OVERALL SHIELDED Temperature range - 40°C to +90°C Specifications: UL13 INSTRUMENTATION TYPE PLIC (UL) 500 MESC 2030 Application Can be used in cable tray, conduit or direct burial application for instrumentation / process control, in dry ar wet lacation © Conductor Plain copper to ASTM B3 , stranded to class 8 of ASTM 8 © Insulation Flame retardant PVC insulation rated 90°C as per UL13. © Pair Colour Code : White and black with pair number on white conductor. © Triple Colour Code White, black and red with triple number on white conductor, © Pairs/Triples Twisting All pairs / triples are twisted to counter electromagnetic noise. © Overall Shielding: Twisted pairs / tripies are cabled with non-hygroscopic fillers if necessary and the entire assembly is shielded with aluminum polyester tape and a tinned copper drain wire © Jacket Extruded black PVC as per UL13, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration. 27 nN Sie MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) PVC INSULATED MULTIPAIR / MULTI TRIAD OVER-ALL SHIELDED PAIRS HE | Oar ESE Cae Pas [Suan maior Worse Teen tometer | timess | tenes | “0.0 | West sawed [ma Non i ine ime_| Karem 22 tae eatinerazawe-lopnae % 7kaaee oe is em aE | oer WERE tase Fane] Svan] imation] omma tet | Aap | tom sioner | thence | “ics | “Ea | Wee awe | Nem ‘on ‘nm ‘nm ase onitezraoawe-lopn0. 2 aE) oor Pa awe | _ no. ye Gene atsauranane Lone. % sae oar Wes Cae Fae awe) | nie fern Gatbabmieawe Vestas » anno tats ePvanne Leake > ™ Sek enn somisawe uones 0 2 INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) PVC INSULATED MULTIPAIR / MULTI TRIAD OVER-ALL SHIELDED TRIPLES a NESE Coe Wiles] Seana Fapox | Aap ‘ameter 80. | Went awe Nom ram_| Kaien ori artanwe-u0Bre 65 T 7x02 7 4 ozi1-02T224W6-U0K8.03| 27x02 34 8211-03122aW6 UOBKS-02 3 7x02 so, 2i1-o4Ta2AW6-U0BR9-0) ooze 23 us G21 o6F224W6-uoeKs-0) 6 7xo28 ie 309 onis-a7V22kWe-U0BKE-03 2 7keae yas o2i1-207224W6-uosKe-03 2 Teeae aa #5 zit a4Te2aWe-UDBKB.02 2 Tea 25 500 bait s2Ta2AW6-UDaKe-09 je 3 xoaee ges 130 5231. 367224W6-UOBRE-OD de 7020 a9 0 ‘SHE MESC cose Wiles | Sans x aoe ‘dameter Oo. cower | We Norm om 72289 dei OFTP0AWE DORKS OF 1 —7¥0307 78 (2290 0711.077208W6-UOBKE-05. 2 7xo307 106 2201 crin-oyToaawG-uase-o) 3 3xea07 na 2292 cris-otTaoawe-uoBKe-33 4 rxeaer ma 2295 Gzi1-067208W6-v0BKE-03 © >xea87 as f299¢ —G212-08770AWE-UDBKE-02 8 7xa307 353 20 G2ens—_gzis-t7Te0aWe-U0BKe-03 we 7xe307 tee ease 0713-167 Z20AWE-UOBRE-09 ae 70307 23 e297 G711-207204W6-UOBKB-09 2 7x0307 2s G22%e G211-247R0AWE-UOBKE-9D 3 Tea307 24 2299 Grii-a7T20awWG-uoBKe-03 me xaa0 237 92300___G211-361204W6-UOBKE-03 3h 70307 302 Bae] aw WES Cade Wie] Seah wor | no Nock 9308 atte a@Awe-UoaKe.0s 2 7K03Re 2303 _ep11-0STaawe-vOBKS-02 3 Fees ago ball oTLeAWG-UoaKe-03 s 7x0a0 07305 grit-oeT@aW6-U0RK8-02 70386 02306 Gzi1-oeTIBAWG-UOBRD-OS a Fx03e ie 2307 att aTIRAWG-UOBKE-03 27x 0386 9308 aLLI6TIBAWG-UOBKE.03 ae 7X08 02309 G7l1.20T18AWG-UOBKB.0) 2 7x0386 onto elke 2% kee 22312 __ba14 36TIeAWG-UOBKE- 03 So 70388 SIZE] oer ESC Code Tees] Seas cawer |W Neem oan13 _onnvorTiawe.u O8K803 7 x0ae@ ® Gana gelio7Tieawe-Voake.oa 2 wm o2s1s 0211-037 seAW6-voBKe-03, > 2a oasie GzLLoarieawe-voaKe-03 a 28 02317 o7i-aerseawe-vo8ke-03 ‘ aus 02318 oB1-0drieAw6-UoBKe-03 & sie Ye oeate —gainazrieawe-vonke.0s 12 758 02320 O21 16TSEAWG-UOUKBOS 14 on 02321 ors .20Tueawe-uoeke02 20 net oaag2 arlaaerieawG-UoaKe-os 24 1427 02323 gzinszTieawo-uo0Ke-03 32 1836 02324 9711. 36T1eAWG-UOEKE.O3 36 2083, 30 So MESC INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) PVC INSULATED MULTI PAIR / MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED Temperature range - 40°C to +90°C Specifications: UL13 TNSTRUMENTATION TYPE PLTC (UL) 300V MESC 7010 Application : Can be used in cable tray, conduit or direct burial application for Instrumentation / process control, in dry or wet location, ‘© Conductor Insulation © Pair Colour Code Triple Colour Code © Pairs/Triples Twisting © Individual and Overall Shielding © Jacket Plain copper to ASTM B3, stranded to class 8 of ASTM BB. Flame retardant PVC rated 90°C as per UL 13. ‘White and black with pair number on white conductor. White, black and red with triple number on white conductor All pairs / triples are twisted to counter electromagnetic noise. Each pair / triple is shielded with aluminium polyester tape and a tinned copper drain wire for maximum electrostatic noise and crosstalk rejection. All pair/triple shields are electrically isolated from each other. Individually shielded pairs/triples cabled with non-hyaroscopic fillers if necessary and the entire assembly is sheilded with aluminium polyester tape and a tinned copper drain wire, Extruded black PVC as per UL13, cil and sunlight resistant, passes flare test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration 4S MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS (TYPE PLTC ) PVC INSULATED MULTIPAIR / MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED PAIRS SHE] baw WEST Coe Pairs | Svante | towbten | Nominal acre | Apron ‘dameter | tides | “theiese | “0 se Na'kern | "rm ‘om nm ‘4089 Oa -OEPOANG-UOBKOOS 2 _—_7K0244 038 Tor ass 4080 cati-osPz2AWG-UOBKEG3 © «3 7KOM4S 038 1DL 9598 4051 GatrosPazawG-UoaKe0s = & 7 xOaea O38, ¥27 109s fos Gars-ouPe2AWE-UOBKES «= § = 7X024a O38 a 12 la, 0405) oe1s-oBPa2AwG-UoaKe? «8 «=P R2e4 O38 12 23 300 ofos4 —cat}-12P22AWG-U0BKO03 12 7X0244 038, aa is 5 2204055 —«GaTI-IgPA2AWG.UOBKEOS 167X028 038, 152 ys 30 cos oa1n-20P22AWG-UOBKED3 — 20 7XKOMS O38 152 1440 94087 Gali 24P22awG.UoBKAO? 2470244 O38 152 26 5S tose Gait-s2P22awG-UoBKe03 © 327X084 O38 7337 bas otoss —eatnaePe2awG-Uoakeos 367X244 OB sag 958 (94069 CaTT-AOPZzAWG-UORKEO3 §— 407X044 O38 17s el 28 04081 __o41s s0P22awG.UOBKAO3 50 7kONd 038, ie 28) 1000 ‘SIE Toner ESC Code Pairs | SuantsX | toaation | Nominal weet | Approx] Anprox siameter | thickness | "uses | OD | weigh tawer | na. esx | "nnn ‘nw am_| ist ‘e062 oai-GePPOAWG-USBKeG3 2 70307 038 TOL 340 24063, o#i2-ospz0awG-UOBKB03 = «3 7X0307 038 127 107130 Ocoee — eaid-osPesawG-Uoakeos = @ = Pxaa07 838 re ia 135, 0c065 Gall-ogPzoANG-UOBKEO} «= «6 = 7xO307 a3 127 2205 Ocoee —catt-oaPeoaweloakan) = 8 «= 7 k0307 ak fe ine 350. 4087 Gatt-zP20aWG-UOBKRO3 127 x0307 OD, 152 rea 368 2 04068 oat tisp20awe-uosKecs 16 = 7Ka307 8 152 aes 45 24069 cat 2oPzoawG-UoBKAO3 © 20 7K0307 O38 use 208 560 04070 GaLi-2ehz0awG-U0BKG-0) 247X030? 08 152 bes 658 Scar! GaizsePeoawe-UoaKeoa a2 7xa307 a3 17 257870 e072 Gail suP20awG-UoBKaO3 36 ©7030?) 038 ue anes 0c073 cali-anPzoawG-UoBKe03 40 «7X0307 Oa 178 282 1055 fora oarn-soPzoAwe-UoBKe03 507 X0307 038 17 Sut__1285 SE | Oa ‘WESC Cole Pare] SyaeeX | tion ] Nominal icket | Avorn. Aapror. ameter | ‘tnctness | "branes | “0D” | Wee came, | no. Norm | "en ‘cm nm _| Kot ‘oca7s —calcaPiaAWGUOaKeas 2 7¥0399- 038 1a Tos — 120 04076 caIL-O3PIRAWG-UoBKaos =} «7 XO 033, wns 04077 calt-ouPiaawG-uoake-os == X0386 «038 127 25 ies 4078 GALL osPaBAWG-uOBKe-c3 © 6 = 7X0386 038 127 145255 os079 oaltoapreawe-Uoske-cs 8 «7 X0386 038 1a ws his oson —caltizmaaweunaKecs 127x038 O38 152 12s ae 18 ode) «Gel LePAsANG-UoBRe-03 Ie TXO386 038 152 208 58s foaog2Ga1z-20Pieawe-Voake-os 207038508 178 2a 740 e083 cain oePLeaWe-Uoake0s 27 X0386 O38 Le 252960 toed Galza2PieAWG-UOsKS0s 32 7xG38e 038, 178 zas ato 4083 O41 36PLEAWE-UOBKE-03 367X038 0B ire 5001230 Seog oul agPlenWe.UoaKegs 4070386038 178 51a 1350 4087 _oaunsorieawe-oaKe-o3 07 X0286 038 203 3511690 ‘oa We Spanx Jaton | Noniralciet | Appron | Anprox ue pee Pas) “ier | ‘tsames | “tues | “BS | We cower |e nek | nm en inm_| kath ‘onoed GairGaPiAWGUGEREG? ~~~ ~~CMOAGS aS 1a m9 155) e089 GartosPigawG-UoBKe0s © «3.7 x0.48B O38 12 129200 24090 calT-osPisAWG-UOBKBOS = & = 74GB O38 aa? 139-250 econ GarropPigawe-UonKe®) «= & «=F xOaSB 3B 152 168360 (94092 GAIL-OBPISAWG-UOBKSOS 87 xOaGs OE 132 ms tas 04093 Gals-12PieawG-UOBKE0) 12 PxatBe O38 152 zoe 62 3b Osopd ATT AGPREAWG-UOBKB-Os 1s 7 X0MBe OR 178 oa? 830 4095 ca1i-20PiBAWG-UOBKS03 26.7 KO.ABB O38 178 261 1010 040% Gali 24PleaWG-UOBKEO) © 3a 7 Knane aR 178 2a2 aes 04097 ontz-22PiaAWG-UoBKeO2 «92S 7KO.4G2 OB 203 32a 1570 04098 CMLL JGPIAAWG-UDBKROS 36 7XO4BB OE 203 Bar 145 4099 GaLI-AOPI6AWG-UOBKe) «40S 7 Koes O38 203 387 to20 4100 CART SOPIGAWGUOBKEO3 507x488 O38 203 3932350 31 Sin MESC INSTRUMENTATION / PROCESS CONTROL CABLES POWER LIMITED TRAY CABLE 300 VOLTS ( TYPE PLTC ) PVC INSULATED MULTIPAIR / MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED TRIPLES SHE] ower WeSC tee Wolet | SiankeX | Toon | Womtaliackel ] Apron | Arron dameer | thetwess | teuness | 0. | elon awe | Wo. Noxmm | em ‘rm m_| Keir ‘aio ost1 G2TZ2AWG-UOBKG-O> P 7x0a 0.38 1a 305 105 oszcz _os11-a3rzzaw6-UosKe-05 5 Txome 038 127 m1 130 (04103 _0411-04722AWG.U0BKE-03 a Teo 038 127 yo 155 (4108 9411-o6T22AW6-U0BKE-05. 6 7x0 638 127 Ms 75 9c105 _a411-28T22AWG-U0BKe-03 B Txoae 038 17 353260 22 0410S ORLL-TzRzaWG-UooKEOS = 127X024 038 152 aes 580 oaio7 —oun-aerazawG-uosKe-Ds «1 == 7X02 OSB 152 208400 103 oft 20Tz2AWG-UOsKa03 = 20 7X02 038 178 234605 oai09 oer 2er22AwG-uosKa-os 747028 058 178 232700 end oANn-aeT22AWG-UORKEDS «= 327X024 OB aa zs 8s Size] _oreer WESC Cade Wales] SwanisX | Wcuaion | Wombat acter | Aspe | Arron, ‘dameer | thetmesr | ekness | 0.0. | elon cower | Wo. Noxxrmm | “rm m rom_| oem 94112 9411 G2TZ0AWG-UOBKe OF 2 1x0307 0.38 1a? 21s ais ogn-esrz0Awe-UoaKs-o3 3 1xo307 038 127 ns 160 (0%138 _oe11-04T20AWG-U03K8-03 4 Txoa07 038 1a Bo 190 04125 o4t1-o6T20AW6-U08Ks-03, & 7X0307 038 152 ter 285 04126 _0421-08T20AW6-U08Ke.-03 8 7x07 038 132 aro as 20 om7—OmLLIRT2OAWG-OBKEOs 127X007 08 152 200 480 e128 omn-terz0awG-uosKa0s «70307038 178 21635 bauu9 — om1n-20720AWG-UOSKE-OS = «20,7007 38 178 253765 02120 o411-24720AWG-UOBKE-05 24 7X0307 O38 176 273990 0221 ‘O411-32T20AWG-UOSKEOS «327X007 038 a 3081s, oa172 __oetr-z4r20AwG-uosKa-os a6 79307 O38 203 5313310 wae] eer TES Cae a a a ‘tometer | ihekness | teanens | OD. | elon cawer | Wo. nex |e ‘om rmm_|_ on ‘8123 G4II-G2TIBAWG-UOBKE-OF 27x03 0.38 127 33 180 124 get1-asTieAWG-UoBKs-03, 3 7x03 038 ar 2198 0125 o411-osTasAw6-UosKe-05, 4 7x0386 438 127 2240 04126 o#11-06TLBAWG-UOBKE.03 6 Txome O38 use ae 388 04127 osii-aeraeAwe-vosxe-o5 8 7x036 030 152 ae? 435 ye om128—geILTaTieAwe-UosKe-03 127x038 08 182 mas 02129 ouli-terieawG-vooKa-03 70386 038, 178 255 15 04130 OAL 20TIEAWG-UOBKBOS = 20, 7KO3B O38 178 zai 990 0x13) oenPerteAWG-uosKe-02 247 K0386 038 178 204 165, on32 OMLL-a7TieAWG-UOSKEOS «= 527X006 O38 203 3491535 02133 OALIETARAWG.UOBKAOD 367 KORBH 038, 203 368 1708 SE] Ore ESE Coe Toles] SianieX | Teauation ] Wonnal ater Tipree dumeer | thekness | eens elo cower | no, Nox | rm Tm Ko 94138 on GETTEAWG UOBKE OD 2 7x04e8 0.38 1a? 200) 08135 O81 O3TI4AW6-LiosKe-05 5 Txogs 038 12 260 04136 9401. 04TAeAWG-U0BKE-02 «7x03 038 152 340 (04137 Oat LobTTeawé-ionke-o5 & 7xode 038 ust a0 04138 411 aBT1eAW6-U0BKe-03, 2 7xoae 038 use 0s 16 08139 aLTAaTIbAWG-VoDKeDS = 12 7xO4MB 08 178 885, aia) our teTagAWG-UosKe-Os t= TXOMBE O38 178 30 andl ORI L2OTUGAWEUDDKE-OS = 207K OKBR 8 we 4380 Oane2 —omnr-28TgAWG-UOBKE-DS «247 KOMBR OSE 203 1670 oai4s —o#n-SeTI6AWG-UoBKeDs = 327X048 O38 203 2155 oci4a 04 THTIGAWG-UOSKED) 97 KOKBB O38 278 2540, THERMOCOUPLE EXTENSION CABLE 300 VOLTS TYPE PLTC-90°C RATING UNSHIELDED Specification: UL13 =! THERWOCOUPLE EXTENSION PLICTUL) 300 MES 2010 Application © Conductor © Insulation © Pair Twisting Assembly Outer Jacket MESC ‘These cables are used on circus where shielding from external interference or other pars is not required, Suitable for cable tray, conduit or direct bural application in dry or wet lecaton Solid Alloy wire as per ANSI Mc 96.1 Flame Retardant PVC rated 90°C as per ULA3. ANSI colour coded cores are twisted to counter electromagnetic noise. ‘Twisted Pairs are cabled with non hygroscopic fillers if necessary and the entire assembly is covered with a Polyester tape if required. ANSI colour coded PVC rated 90°C as per UL 13. Jacket is oil and Sunlight resistant and passes IEEE-383 Flame Test. COLOUR CODE AND LIMITS OF ERROR ANSI Pounve Wire ‘Negative We Tock Sandod| tye [“aoy ‘om TAoy coe Colour | _Range’c | Error Limit. (2) &% — Chromet Purple ‘onstanton Red Purple 18 w 208 2wze x ton Wine CConstantan Red Bick 18 40204 nae chrome! Yellow ‘lume! Reo Yellow “18 19206 are TK ___ Copper Bie Constantan Red Be =59 1093 ose EX-TYPE i oe Wate ‘aa el | — Aras] ape “Wass oo | Meme sawe_| ns, = me | atm 16 £100) OTEOIPYEA WE-DOPREOS 089 6a 35 51002 O1E1020204 WG-LOPREOS 101 Be cs £1003 O-03020A WG-UoPREDS tot 80 8 E1004 O1E1-04°20A WG-UOPREOS 101 97 01 E1005 11-6020 WG-UoPRE-OS 127 ny 180 E1006 O1ET-D8P20A WG-UOPRE.OD 2 mm £1007 O1€1-12020A WG-UoPRE.OS 2 waa 251 20 EV00R OTE1-16P20A WG-U0PREO is tes 338 E1009 0161-20208 WG-LOPRE-O3 152 182405 EIOIOO1E1-24P208 WG-UOPRE-03 1s 36 aa E101) 0161-32P208 WG-UOPRE-02 432 ai 60s E1012 O1E1-36°20A vic UoPRE-3 178 BB 66 ‘E1013. O1E1-40P20A WG-LOPRE-OS v8 ma 761 E1014 _O1E1-50P20A WG-UOPRE.OS ia 23m 33 34 a Sin MESC THERMOCOUPLE EXTENSION CABLE 300 VOLTS TYPE PLTC-90°C RATING UNSHIELDED JX -TYPE esa WESC Cote Pais] Contcor | ator | Nominal socet | Anwrox. | Aer Diameter | Tae: | “Thames | “Oo.” | Weim wwe | se ma = om_| on 16 _ ot 038 191 97a £4003. O4#1-03P708 WG-UOPRE-02 3 on 038 w no 150 1004 O481-04P20A WG-UOPRE-OS 4 ost 038 ce 26 20 £4005 O4E1-06P208 WG-UOPRE-OZ 6 081 038 Ww 32246 4006. O8E1-08P20A W-UdPRE-OD 8 oat 038 152 16030 £4007 04E1-12P20A WG-UOPREGS 12 038 182 9486 20 £4008 O4ET-16P2OA WG-LOPREDS 16. 038 132 ar) £3009 04€1-20020A WG-U0PHe-O2 20 038 152 m2 6a EsOI0 041240208 WG-UDPREGS 28 OT 038 178 a asa F401) GAEI-32020K WG-UoPReG: 32 038 Ve 7s E4012 O4E1-36P208 WG-UDPEGS = «36 038 178 2681037 £4013 O4E140P708 WGUOPREG? 40 OB) 038 Ve bos 1262 37 38 Siu MESC THERMOCOUPLE EXTENSION CABLE 300VOLTS TYPE PLTC-90°C RATING PAIR & OVERALL SHIELDED JX -TYPE Se | Oe WEE Case ais | Corer | _aiiien | Nonna | Approx appro ianeter | Thceess | “Themes | “O00. | Weare anc |e. ‘a om ES ron |_ Kaan TiO — OATT-OFPROR WG-UOBKE-OS 7 oat 038 Tor 90 cy 44002 0441-03P20A WG-U0BKE-03 a ost 038 101 oy m2 34003 04J1-04P20A WG-U0BKE-03 4 oat 038 wow 44004 0411-05°20A W-U0BKa:03, 6 oar 038 17 6199 38005 O4s1-08P20A. W6-UOBKE-03 8 oat 038 12732 54006 041-1220 WG-U0BKE-03 2 OB 038 152160355 20 44007 o4yt-16P20A W-0BKS.03 6 oat 038 132 799 “44008 0411-20P20A WG-L0BKa-03, 20 oat 038 1295s 34009 04s1-24P20A WG-UOBKs-03 2 ost 038 132021232 wo10—04N1-32P208, WG-U0BKE.03 32 ost 038 17% 4a BHO “Wort 04s1-26020R W6-UOBKE-03 36st 038 788790 “Wor, O4NT-40P20A WG-U0BKE-02 40 Bt 038 1782681019 4O13__O4/1-5020A WG-UOBKS-03 so oat 038 ye 951240 KX -TYPE ue | bee West aie Pars | Conducar | inainten | Wonalunet | appre | Appron Dumeer | Thales | 'Thelees | “OD. | Were awe | me. om mn = fem | Kon K4001 _O4KI-02P20A WG-UOVLB-O3 2 ost 038 ry 30 39 4002 O4Ki-03020A WGUOYLE-OS 3 oat 038 r01 374 4003 04KI-04P20A WG-LOVLE-03 a oat 038 ay 0150 4004 08K'-06P208 WG-UOYL-03 6 ost 038 127126200 00s _o4KI-08P208 WG-LOYLE-03 8 oat 038 a7 aS 4006 08Ki-1220A WG-UOYLE-OS 2 OB 038 152160389 20 Kao? —_04Ki-16P20A WG-UOYLE-03 % ost 038 1527958 4008 08K'-2020A WG-LUOYLBOS «20, OT 038 116 SAT 4009 O#KI-24P20 WG-LOVLE-03 24 oat 038 1221269 4010 O8Kt-32P20A WG-UOYLE-03 32 ost 038 a) Kao 04KI-36P20A WG-UOYL8-03 3 at 038 We 28790 4012 Oaki-40P20A WGAYL8DS = 038 178-68 1030 4013 O9K1-S0P20A WE-U0YL8-03, so oat 038 17a es 1254 TX -TYPE Se | oem WERE Cote Pars | Concer | nation | Wovinal deck | Approx | Amro Diameter | Tuces | “Thebes | “On. | Wei awe | te. m i co fan | ResKe Taoo! __O«TT-O2P20A WE-UOBLE-03 2 oat 038 70 90 39 74002 O4TT-03020A WG-U0BL8-03, 3 oat 038 vor 9713, 4003 0471-04920 WG-UoaLe-03 4 oat 038 ww ost T4004 0471-06204 WG-UOBLB-03 6 ost 038 427126202 T4005 4TI-08h20A WE-UOBLE-03 8 oat 038 171322 ‘T4006 O4T1-12P20A WG-U0BLE-03, 2 oR 038 132 16032 20 T4007 047-1620 W6-UoaLe-03 % oat 038 15279458 T4008 04T1-2020A WG-U0BLE-03. 2 Ost 038 152198552 T4009 0471-24204 WG-UOBLB.03 24 ost 038 132 2126s ‘TaoIo O47 1-42P20A WE-U0BLE-03 2 ont 038 1% ae BSF HOI 04TT-36P20A WG-U0BLE-03 36 Oat 038 e257 98 4012 O4TI-40P20A WE-U0BL8-03 40 OB 038 1782681041 “T4013__O4T1-50P70A WG-U0BL803, so oat 038 178951267, bw. MESC THERMOCOUPLE EXTENSION CABLE 300 VOLTS TYPE PLTC-90°C RATING WIRE ARMOURED, OVERALL SHIELDED Specification: ULI3 THERWOCOUPLE EXTENSION PLTG (UL) 300 MESC 2010 Application: Conductor Insulation Pair Twisting Overall Shielding Inner Jacket : © Wire Armour : © Outer Jacket : These cables are used on circuits where shielding from external interference is required, ‘but shielding between pairs is not critical. Suitable for cable tray, conduit or direct burial application in dry or wel location. The wire armour provides longitudinal strength for use as ‘a messenger cable or for support in vertical drops (NEC SECTION 300-19) and provides protection against mechanical damage, Solid alloy wire as per ANST MC 96.1 Flame Retardant PVG rated 90°C as per UL13. ANSI colour coded cores are twisted to counter electromagnetic noise, Twisted pairs are cabled with non-hygroscopic fillers if necessary and the entive assembly is shielded with aluminium polyester tape and a tinned copper drain wire, ANSI colour coded flame retardant PVC rated 90°C as per UL13. A serving of soft raund galvanized steel wires is applied with 90% minimum coverage. ANSI color coded PVC rated 90°C as per UL13. Jacket is oll and sunlight resistant and passes IEEE 383 flame test. COLOUR CODE AND LIMITS OF ERROR ANS Poskive We Negative wire eck] Tempeatue | Standard Type iy ‘Colour oy Colour Colour | Range °C [Error Limit (4) Come Purple Constantan Red Pompe 18 9208 22x x tron white Constantan Red Black 18 to 204 2we KK —Chromel Yellow ‘lume Red Yellow “18 to.208 22°C TK Copper Blue —-7X0s15 0.76 1a 34126 1371 7614-03C14AWG-UOBKE-00 «3 7X06I5 0.76. aaa 100 150 01372 7614-04C 14AWG-UOBKE-00 4 7XO0IS O76. aaa 109 180 01373, 7614-05C14aWG-UOBKS-00 = 5 7XOSIS 0.76, aaa 92s 01374 7614-06C14AWG-UOBKE-O «== 7XO4IS 0.76 14 131 260 01375 7614-070 14AWG-UOBKe-00 «7 = 7XO4I5 O76 aaa 1270 01376 764-08C14aWG-UOBKS-C0 —«8_-—=S7XO6IS 0.76. 132 1s0 335, 01377 7614-09C4AWG-UOBK8-00 «9 7XOGIS 0.76. 152 160380 01378 7614-200 4AWG-UOBKE-00 10S 7X06I3 O76 12 174405. 3401379 7414-12C14AWG-UOBKE-0O 12 7XOSIS 0.7, 182 9 460 91360 7614-250 14AWG-UOBKB-00 15 7XO-6IS 0.76 152 138560 01381 7614-16C14AWG-UOBKE-00 16 7X0615 0.76. 182 192590 01362 7614-19 14AWG-UOBKS-00 19S 7XO.615 0.76 152 208 470 01383 7624-206 14AWG-UOBKB-00 20, 7XOHIS 0.76, 203 230765 01384 7614-24C14AWG-UODKE-00 24S 7XO61S O76. 2.03 253885 01385 7614-25C14AWG-UOBKE-00 25 7XO6IS O78. 2.03 23 95 01386 7e14-27C1aawe-UoBKs-00 27-7 X OBIS 0.76 2.03 259 975 01387 7e14-30C1AAWG-UDBKA-0O 30, 7XO6IS O76. 2.03 268 1085 01388 7614-37C14AWG-UOBKE-0O 37, 7XOGIS O76 2.03, 28 1265 1389 7624-48C14AWG-UOBKE-0O 4B 7KO4IS 0.76, 2.03, 32.9 1600 91390 _7614-b1CMAWG-UOBKS-GO6L_—7XO61S 0.76, 203 358 1965 4 Noe XHHW Sia, comples with NEMA WC70, INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) XLPE INSULATED MULTICONDUCTOR UNSHIELDED CABLES SE] oviee ESE Coe Coane | Svensk oy a ‘dometer ‘eke ‘op. | Web ce) |W. Nee oy om] an D138 7eleo2e12AwG-vOBKR0O 2 —~7X0.775 aaa 104 165 01392 7614-03C}2AWG-UOBKAGD = «537X075 aaa io 195 01393 7614-o4Ca2AWG-UORKAGO 4-7 XOTIS aa 320 240 01394 7614-osc12AWG-U0BKBCo = 57 XO.775 aaa aa 290 01395 7614-06C12AWG-UOBKB00 = «= XO.775 asa 433378 (01396 7614-07012AWG-U0BKB-00 «7-7 XO775 as 153395 01397 7e14.08C12AWG-UOBKB-CO 8 = X07. 352 aes 455, 01398 7614-09C12AWG-UOBKB00 = «9 = 7X0.775 152 a7 10 01399 7614-10G124WG-VOBKE-09 10 7X0.775, ase a2 505 12 (01400 7614-12612AWG-UOBKE-00 «12 -7X0.775 352 199630 01401 7514-15G12AWG-UOBKE-00 15 XO.775, 2.03 230 15 1402 7614-16C12ANG-U0BKB.00 167 X0.775 203 23.0 860 or403 7o14-19¢12AWG-UOBKA-09 «197X075, 2.03 242 980 O1404 7614-20C12AWG-UoBKs-00 20-7 X0.775 2.03 255 1040 0140s 7e14-26C12AW6-UOBKB-00 24 «7 X0.775, 2.03 21 1210 o1406 7614-25C120WG-UOBKACO 28 7X0775 203, 261 1255 01407 7614-27C12AWG-U0BKB-00 27 = «7 X0775 2.03 268 1340 01408 7614-30C12AWG-UOBKB.0O 30,7 X0.775 203 298 1465, 01409 7614-376220WG-U0BKB-00 377X075 O.76 2.03 3211755 1410 7614-48C220WG-U0RK8-0 4B 7X0775 O76, 2.03 367 2225 onal 7o1461C12AWG-UOBKE-00 617X075 0.76 2.03 400 2750 SIRE] der THESE Code ‘coawaare | Sandix ] Tosuaion [Nominal wcket | Agpron | Approx ddanetee | thevness ness oo. | Weg coe | wo. NexXemn rm om fmm__| kate oraz 7e1so2ci0AwG-UOsKeGD 2 70978 0.76 3a m6 220 01413 7614-03C104WG-U0RKBCO = «3 7XO97B 0.76, a 123 270 91414 7614-04C10AWG-U08KB-00 4 = 7X0.978 O76 ase 142355 1415 7614-05C10AWG-U0BKB-00 = «5 7X0.978 0.76 152 155 430 01416 7614-06C10AWG-VOBKS-00 «=X OTR 0.76, 152 wi sis, 01417 7614-07C10AWG-U0BKA-00 = «7 = 7XO97B O76 ase va 550 01818 7o14-08C10AWG-VOBKS-00 = XO9TE 0.78 152 ree 638 01419 7614-09C.10AWG-U0BKA-0 = «9 = 7XO87B 0.76 1s 339720 01420 7614-10G10AWG-VOBKE-00 10«S 7X 0978 0.76, 2.03 227 a1. 10 01421 7614-12C10AWG-U0BKB-O0 127 X0.97B 0.76 2.03 234 940 01422 7614-15G10AWG-UOBKE-00 1570978 0.78, 2.03 25.9 1150 01423 7614-16CLOAWG-U0BKA-GO 167X097 O76 2.03 259 115 01424 7514-19C10AWG-UOBKS-00 19 «7 X0978 0.76 2.03 27.2 1385 01425 7614-20C10AWG-UOBKACO 20,7 X0.978 0.78, 2.03 287 1470 01426 7614-24CLOAWG-UOBKE-00 247X098 0.78 2.03 3181725 01427 7614-25C10ANG-U0BKBGO 25 7KORTE O78 203 3181790 1428 7614-27C20AWG-U0BK8-00 277X097 O76 2.03 325 1905, 01429 7614-30C10AWG-U0BKB-00 © 30,7 X0.97B 0.78. 2.03 33.7 2005, 01430 7614-37C10AWG-U08KB00 377X097 0.76 2.03 36.3 2520 1431 7614-48C10AWG-UOBKB.GD 487 X0.978 0.78 2.03 416 3205, 45 46 Sin MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) XLPE INSULATED MULTICONDUCTOR SHIELDED CABLES Temperature range - 40°C to +90°C Specifications: UL1277, UL44 & NEMA WCS57/ICEA S-73-532 TYPE Te (UL) 600 V MESC 2610 Application + Industrial signalling and process control crcit in dry or wet locations. The cable can be used in cable trays conduit or direct burial application © Conductor Plain copper to ASTM B3, stranded to class B of ASTM BB. Insulation Flame retardant XLPE to ICEA S-73-532 . UL Type XHHW conductors rated VW-1 © Assembly Insulated cores are cabled and shielded with aluminum polyester tape for 100% coverage with a tinned copper drain wire. © Jacket Extruded black PVG as per UL1277 , oil and sunlight Resistant, passes flame test as per IEEE - 383 (70000 BTU ), The jacket is impervious to vapour and moisture penetration Colour Code Conductor No. Colour 1 Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) XLPE INSULATED MULTICONDUCTOR SHIELDED CABLES Sie] Over WESC Case ‘onaicon | Seante X | Inslalon | Namimalsacket | Agpron | Aapor Diameter | aiewness | inieves | 0.0. | Went cawer | no NoXemm | em on rrm_|_ Kaiki 02325 _ 6210-020 16AWG-UOBKE-06 2 7Xoass 06a iia 87 no 02326 0214-090 16AWG-UOBKE-06 3 7X0aM8 0.68 aia aa 125. 02327 0214-040 16AWG-UOBKB-06 4 7X0488 068 na 98 140 02328 0214-050 16AWG-UOBKE-06 5 7X04Ba 084 aaa 10.7165 02329 0214-06 16AWG-UDBKE-06 6 7X0488 06a aaa us 190 02330 0214-070 16AWG-UOBKE-06 7 7X0aa8 0.64 aaa 115200 02331 024-08C LeAWG-UOBKE-06 8 -7X0488 0.64 na 128 230 02332 0214-090 16AWG-UOBK-06 9 7X0aae 0.64 use 41280 02333 O214-10C16AWG-UOBKE-06 10ST XO.MBH 0.64 132 asa 245 1 02334 0214-12G16AWE-UOBKE0G 127X048 OA 152 1556335 02335 O214-15C16AWG-UOBKA-06 = 15 7X0.4BR 0.64 152 wa 400 92336 0214-16C16AWG-UOBKB-06 = 167X048 O64 152 wa 420 02337 0214-19C1GAWG-UOBKE-06 «19S 7X O.ABB OGM 152 1e0 475 02338 0214-200 16AWG-UOBKE-O6 = 207X488 O64 152 189 500 02939 0214-24C 16AWG-UOBKE-06 247 XOBR 0.64 152 208 580 02300 0214-25 14AWE-UOBKE-06 25. 7X OAER OOM asa 20.8 600 2301 0214-270 16AWG-UOBKE-06 = 27-7 X 0.488 O.bd 203 223 685 02342 0214-30C16AWG-UOBKE-0G = 30S 7X O4RR 6A, 203, 230745 02343 0214-37C16AWG-UOBKE-05 377 X04BB 0.64 2.03 24.7 880 02344 0214-48C16AWG-UOBKE-06 = 48 7X O.ABR 0.64 2.03 280 1100 02345 OP14-41C16AWG-UOBKE-06 61 X04BB 0.64 203 30.4 1340 See] Oa WESC oe Consicios | Seands X | Tnslatcn | Nominal docket | Approx | Aopor Diameter | themess | tienes | 0.0. | Wen xwes | a. Nexto | nn os me | Karam ‘02346 0214-020 14AWG-UOBKE-06 2 7xosis 076 aaa 39 150 02347 0214-030 14AWG-UOBKE-O8 3 7X0615 O76 ana aos 175 02348 0214-040 14AW6-UOBKE-08 4 7X0815 076 aaa 14195 02349 0214-05C 14AWG-UOBKE-O6 5 7xX0615 O76 an 24238 92350 0214-060 14AWE-UOBKE-O6 6 7X0615 076 aaa 134 270 02351 0214-070 14AWNG-UOBKE-O6 7 7X0615 076 aaa 134285 02352 0214-080 14AWG-UOBKE-08 8 7X0615 076 152 153355 02353 0214-090 14AWG-UOBKB-06 9 7Xobs 076 ase 163 395 02384 0214-10 1AWG-UOBKE-06 ©=— 10S XOBIS 0.76 ase v7 420 1s 02355 oznAaZCI4AWG-U0BKe-06 = «12, 7XOGIS 0.76 152 182480 02286 —O2ILISCIAAWG-UOBKE-0G «18.7 XOMIS 0.76 152 201 575 92357 O214-16014AWG-UOBKE-06 = 187K OSIS OTE. 152 2.1 610 02358 0214-19 14AWG-UOBKB-06 = 19,=S 7 XQBIS OTE 203 222 740 02359 0214-200 14AWG-UOBKEO6 = 20, 7XO6IS O76. 2.03, 233 700 92360, ZAC 14AWG-UOBKE-06 24 TXOGIS 0.76. 203 25.6 905 02361 BSGL4AWG-UOBKE-06 25-7 XOKIS OTH 203 6 935 02362 0214-270 14AWG-UOBKE-6 —27_—STXOKIS 0.76 2.03 26.2 995 023630214 30C1AAWG-UODBKE-06 = 30ST XOGIS O76 2.03, 27.1 1085 92364 0214370 14AWG-UOBKE-06 577 X OBIS 0.76 2.03 20.1 1285 0236S 0214480 14AWG-UOBKE.O6 = 487K OMIS O76 203 33.2 1620 02366 O214-4IC14AWG-UOBKE-O6 —61_—7XOSIS 0.76 2.03 3611985 + Non XHHW size, complies with NEMA WCS7, 47 48 Se MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) XLPE INSULATED MULTICONDUCTOR SHIELDED CABLES Te] om WES tae Condiciors | Svards X | Inevlaion | Norira Jacket | Aeon. | Aawrex: Diameter | themes | thickness | 0. | else awa | We Neck mm | om ‘on rem | an (2367 0214-020 T2AWG-UOBKE-DG 2 7x0775 0.76 Tia 70.9 — 195 02368 0214-03C12AWG-UOBK8-06 3 -7X0775 076 aaa ns 230 2369 0234-08C120WG-UOBKE-06 4 7x0775 076 Lis Ws 5 02370 0214-05¢12AWE-U0BK8-06 5 7x0775 076 134 we 3s 02371 0214-06C12AW5-UOBK8-06 6 7x0775 O76 ase 15.6 400 02972 0214-07612AW6-UOBK0-06 2 70775 076 asa 1365 02373 0214-086 12AW6-UOBK8-06 8 7x0775 076 ase eo 475 02374 0214-096 12AW6-U0BK8-06 9 70775 076 1s2 380535 02375 0214-20C12AWG-UOBKB06 «107X775 0.76 ase Ws 565 1202376 0214-126 12AWG-UOBKB-06 = 127X075 0.76 ise 20.2 655 02377 o2t&-SCIZAWG-UORKE-06 «187X075 O76 203 aaa eo 02378 0214-16C12AWG-UOBKE-06 = «16 7X0.775 076 2.03, 233 885 02379 oat¢-19C12AWG-UOBKB-06 «197X077 0.7% 2.03 245 1005 2390 0214-20C12AWE-U0BKEOS = 202 7X0775 O76 2.03, 25a 1065 02381 0214-2C12AWG-UOBKE-06 «24.7 X0775 0.76 2.03 26.4 1240 (02382 0214-25C12AWG-UOBKE-06 257X075 0.76 2.03, 26.4 1280 02383 0216-27C12AWG-UOBKE06 «27S 7XO.77S O76 2.03 2911365 02384 0214-30C12AWG-UOBKE-06 = 307X075 0.76 2.03, 301 1495 02385 0214-37C120WG-UOBKE-06 —«37S7XO.TIS 076 2.03 324 1785 02386 0214-48C12AWG-UOBKE06 = 487 X0775 0.76 2.03, 3702255 02387 __0214-61C120W5-UOBKE-06 ___61_—*7X9775_O76 2.03 40.3 2760 ‘Sie | Ovaer ‘MESC Code entice | Sears X | tosdaton | Nominal Jace | Approx. | Approx Diareter | ticess | thickness | 0.0. | lane re a ok | nm mn mm_| kann 02368 0234-0203 0AWG-UOBK6-06 2 7X0978 076 cary 2a 265 02389 0214-03C10AW6-UoBKa-08 3 Tx0978 076 134 ze 35 02390 0214-08¢ L0AWE-UOBK8-05 4 7x0978 076 use 147390 (02391 0214-05C10AW6-UOBK8-06 5 7x0978 076 ase 16065 02392 0214-06C 10AW6-UOBKE-06 6 70978 076 use 74550 02393 0214-07C10AW6-U0BK#-06 7 70978 076 sz 745385 02304 0214-086 100W5-UOBK8-06 8 7x0978 076 use 189670 02395 0214-09C10AWG-U0BKe-06 9 7x097@ 076 sz 20.2 750 02396 0214-10G10AWG-U0BKB-06 «10S 7X0.978 O76 2.03 230 850 10 02397 0214-12C10AWG-UOBKe-06 = 127 XO97TE OTH 2.03 23.7975 02398 0214-1SCLOAWG-UOBKE-06 «15 7X0.97B 0.76 2.03 262 1185 02399 OZ14-16CIOAWG-UOBKE-06 16.7 X0.978 0.76 2.03, 262 1250 02400 0214-19C20AWG-U9BKE-06 «18S 7X0978 076 2.03 275 1425 02401 0214-20C10AWG-UDBKE-06 = 20-7 X0.978 0.76. 203 29.0 1505 02402 0214-24C10AWE-UOBKE-06 —«-24—=S7X0.978 OT 2.03 3211765 02403 0214-25C10AWG-UDBKE-06 = 27 X0978 O76 203 321 1630 02404 0214-27C204WG-VOBKE-06 «27S 7X0978 O76 2.03 328 1945 02405 0214-30C10AWG-UDBKE-06 = 30,7 X0.978 0.76. 2.03 240 2135 02406 0214-37CLOAWG-UOBKE-06 «237,-=S««7X0.978 O76 2.03 366 2560 (02407 0214-420 10AWG-UOBKE-06 467.0978 0.76 2.03, 41.9 3250 INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) PVC INSULATED MULTICONDUCTOR UNSHIELDED CABLES Temperature range - 40°C to + 90°C Specifications: UL1277, UL 83 & NEMA WC7O/ICEA S-95-658 as TYPE Te (UL) 600 v MESC 2010 Application Industeial_ signalling and process control circuit in dry or wet locations ‘The cable can be used in cable trays conduit or direct burial application © Conductor Plain copper to ASTM 83, stranded to class B of ASTM B&. © Insulation Flame retardant PVC rated 90C to UL 1581.UL Type THHW conductors rated VW-1 © Assembly Insulated cores are cabled with suitable non-hygroscopic fillers and polyester binder if necessary. © Jacket Extruded black PVC as per UL1277, oll and sunlight resistant, ppasses flame test as per IEEE - 383 ( 70000 BTU ). The jacket is impervious to vapour and moisture penetration. Colour Code Conductor No. Colour 1 Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request. 49 50 Sie MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) PVC INSULATED MULTICONDUCTOR UNSHIELDED CABLES Siw] Order WESC Cade Conaacos | andeX | Toston | Nomar ackat | Approx | Approx Diameter | heiress | "thetness | “O-D. | Wels awe | Wo Nooxmn | ron i smn _| Kar 01452 __7511-02616AW6-U9BKA-00 2 7X0808 0.76 uaa a7 107 01433 7311-03616AWG-U0BK8-00 3 7X04 0.76 aaa 92 127 01434 7211-04C 16AWG-UOBK8-00 & -7X0488 076 aaa 99 150 01435 _7312-05C16AWE-U0BK8-00 5 7X08 0.76 aaa aos ish 01436 7511-06¢16AWG-U03KA-00 6 -7X0488 076 aaa 12.0 220 01437 7311-07¢16AW6-UoBK8-00 7 -7X0488 076 ana 120230 01438 7311-08¢16AWG-v08Ka-00 8 -7X04B8 076 aie 130 268 (01439 7511-096 16AWE-UOBK@-00 9 7X04 0.76 ase 146 330 01440 7311-106 16AWG-U0BK8-00 wo 7X04 0.76 152 asa 343 16 0144-75126 16AWG-VOBKE-00 1 -7X0488 076 12, 163392 + 01442 7311-15CI6AWG-UOBKA-00 157X048 O76 use aso 475 01443 7311-166164W6-U0BK8-00 we 70488 0.76 as2 360 501 o14es — 7311-19C16AWG-U0BKE-00 yw 7X0488 0.76 152 aes 567 01445 7312-20¢16AWG-U0BKe-00 27 X0aa8 0.76 se 299608 01446 —_7311-24G16AWG-UOBKA-00 2 -7X0488 0.76 2.03 23.0 754 01447 7312-25¢16AWE-UOBKE-00 2 © -7X0488 0.76 2.03 23.0 78 01442 7211-27C 16AWG-U0BK@-00 27-7 x0488 0.76 2.03 235 B26 01449 7311 30C16AWG-UOBKE-00 307X048 O76 2.03 243901 01450 _7311-37G16AWG-W0BK8-00 377 X0488 0.76 2.03 21 1070 01451 7311-48C16AWS-UOBKs-00 a 7X 0488 0.76 2.03 20.7 sar 01452__7311-616 16AW6-V0BK2-00 gL 7x 0488 0.76 2.03 3231655 Se | Oar WESC Cale Conan | Svandx | Teation ‘prox. | Approx Danmeter | heen Ooo. | eigt cane | Wo. exam | mm on _| Kahr 01453 7311-020 14AWE-UOBKE-00 2 7x0e1s 124 lie no 17 01454 7321-03624AWG-UOBKB-00 3 7X6 114 aaa aL 203 01455 _7521-04C14aW6-UnBK@-00 & 7xX061s 134 aia v7 246 01456 7311-05614aWG-oBKe-00 5 7X0615 14 182 ar 323 01457 7311-06C14AW6-U00K8-00 6 70615 14 152 162389 0145 7311-076 14AW6-UOBKE-00 7 7X65 114 asa. 16.2405 014s 7311-08C 14AWG-W0BK8-00 8 —7X0615 14 152 a7 ara 01460 7311-09614AW6-UOBKE-00 9 7X08 Lia 152 aa 52 01461 _7311-10C 4AWG-V0BKs-00 wo 7Xo6Is 114 152 204 557 14 01462,_-7311-126144W6-UOBKE-00 7X05 Le 152 212 643 01463 7311-15 14aW6-v0BK8-00 17X05 Lae 2.03 244 638 146s 73L1-16C14AWG-0BKE-00 ie 7X05 14 2.03 244 08. 01465 7311-19 LaAWE-UOBKE-00 1 7x0sS Le 2.03 25.7 1005 01466 7311-206 14AWG-OBK8-00 20 -7xoms La 2.03 271 071 01467 7311-24 4awG-U0aKs-00 2 7X05 14 2.03 29.9 1240 ‘14a 7311-2561 4AWE-UOBKE-00 207X065 114 2.03 29.9 12e2 01469 _7511-27C14aWG-voaK8-00 277X065 1a 2.03 30.6 1360 (01470 -7911-30614AWG-U0BKE-00 300 7X06S (Lae 2.03 31.5 1486 01471 7311-37C14AWW6-v0aKs-00 37 7X061S 1a 2.03 3411779 01472 7311-486 14Aw6-oBKe-00 a -7X0615 14 2.03 3o1 2356 01473 7321-616 144WV6-W98KS-00 pL 7X05 1a 279 41 2930 + Non THAW siz, complies wit WC70. 4 ip MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) PVC INSULATED MULTICONDUCTOR UNSHIELDED CABLES Sie] Oe WESC cose Conaacons | SuardcX | nslalon | Nominal vacket | Anpron | Repron Diameter | thickness | tnieeness | 0-0. | Velot wer | Nock |r nn mm] kadkon 01474 _ 7311-026 12AWG-UOBKE-00 2 7xo77s ila 1s ne 23 (01475 -7311-03612AWG-UoBK8-00 3 7ko7 114 34 a6 258 01876 —_7311-04C12AW6-UOBKe-00 4 7xo0775 14 as 146340 01477 7311-05C12AW6-LOBKE-00 5 7Ko775 114 asz 360413 01478 7311-06C 12AWG UOBKE-00 6 7x07 14 as e495 01479 7311-070 12AWG-VoBKe-00 7 7Ko0775 114 use 76 519 or4g0 7311-08C12AW6-UOBKE-00 8 7Xo775 aa ase 191 606 (01481 7312-09 12AWG-UOBK8-00 9 7K0775 14 182 205 697 014g2 7311-10C12AWG-UOBKS-00 «10 7KO77S 11a 203 233774 12 014837312120 2AWG-UOBKB00 = 12 7XO77S 114 203, 24.0 88 o1ed —7511-15C12AWG-UOBKG-00 15 7KO775 114 2.03 265 1081 (01435 7312-16C12AWG-UOBKB-00 16S 7KOTS 114 203 266 143 Orage 7511-19C12AWG-UDBKS-00 «19S 7KOT7S 114 2.03 28.0 1302 i487 7317-200 12AWG-UOBKB-00 207X775 Ld 2.03 296 3391 o14ea 7311-240 120WG-UOBKE-00 24 7KOT7S 11a 2.03 3271615 01489 7311-25C12AWG-UOBKE-00 = 25 TKOT7S 114 2.03 3271673 0199 7s11-27C12AWG-VOBKG-00 27 TKOITS 1.14 2.03 335 17as i491 7312-30C22AWG-LOBKE-09 «307X075 1A 203 346 3989 02492 7311-37C12AWG-UDBKE-00 «37? 7K0778 14 2.03 37.4 2345, 1495 _7311-48C.12AW6-U0BKE-09 aX 0775114 279 aaa 5130 Ba] Oner WESC Cade Consicors | Stareix | rao | Nowitalsecket | Aspro | Aroron Diameter | cise |" thceress | 0-0. | elon enwer | no osx |" ‘ rmm_| Kas 01494 _ 7311020 10AWG-VOBKE-00 2 7xos7 114 1a 131276 (02495 7311-03¢ 10AW6-LOBKE-00 3 7Koo7% 114 use 147367 01496 7311-086 10AWG-UoBKa-00 4 7xoa7e 114 se eo 46, (01497 7312-05C10AW8-UOBKE-00 5 7xo97e 114 use 176545 01498 7311-06C19AWS-LOBKB-09 6 —-7ko97@ 114 as roa 655 01499 _7312-07C10AWG-LOBKE-09 7 7K097% 114 ase 19a 695 ‘02500 _7311-08C 10AWG-LOBKe-00 8 7xos7e 114 203 22 8 ‘01501 7312-09C10AWS-UoBKa-00 9 7x09 114 2.03 237988. o1s0z 7311-10C1oAWG-VOBKe-00 = 10S 7X07 114 2.03 287 1027 to 02503 7312-12C1OAWG-WOBKE-00 = «127 KON7E 114 2.03 266 1191 01504 7311-1SC10AWG-UoBKe00 «157X971 2.03 29.4 1450 01505 7312-16CLOAWG-UOBKE-00 = «16 TKO97E 114 2.03 29.4 1537 01506 © 7511-19C10AWG-UOBKE-00 «19.«S7XOS7B 114 2.03 3101762 (02507 7311-20C10aW6-U0BKB99 = «202 7X0.978 114 2.03 3281879 01508 | 7311-24C10AWG-UOBKE-CO «2S 7XOGTE 114 2.03 3632191 01509 7312-25C10AWG-VOBKE-00 25 7K097@ 114 2.03, 363 2272 01s1073)1-27C10AWG-UoBKe-00 «27S K097B 114 2.03 372 2a7e o1stl 7311-30C10AWG-UOBKe-0o 307 K0.978 114 2.03 3e5 2663 01512__7511-37C10AWG-UOBKG.00 377 KOS7E 1.14 2.05 4175221 51 52 Sin MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) PVC INSULATED MULTICONDUCTOR SHIELDED CABLES Temperature range - 40°C to + 90°C Specifications : UL1277, UL83 & NEMA WCS57/ICEA S-73-532 TYPE TG (UL) 600 V MES 010 Application Industeal signalling and process contro! circuit in dry or wet locations. ‘The cable can be used in cable trays conduit or direct burial application, * Conductor Plain copper to ASTM B3, stranded to class B of ASTM BB. * Insulation : Flame retardant PVC rated 90°C to UL 1581. UL Type THHW conductors rated VW-1 + Shielding : Insulated cores are cabled and shielded with aluminium polyester tape for 100% coverage with a tinned copper drain wire. + Jacket Extruded black PVC as per UL1277, oil and sunlight resistant, passes flame test as per [EEE - 383 ( 70000 BTU ). The jacket is impervious to vapour and moisture penetration. Colour Code Conductor No. Colour 1 Black 2 Red 3 Blue 4 Orange 5 Yellow 6 and above Black with number printing Other colour codes can be manufactured on request INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) PVC INSULATED MULTICONDUCTOR SHIELDED CABLES See] Oe WesCo ‘Condit | SeanaX | Tesaaion | Warimalsneket | Appoe | Appr Diameter | iciress | tines | 0.0. | ein cawer| Nok | mm om om_| ain 2408 G211-02CT6AWG-UOBKE-O6 27X08 0.76 Tat 30 U7 (02409 0221-03¢ 16AW6-UOBKE-06. 3 7X04 0.76 aad 95137 02820 0211-04C 16AWG-VOBKE-06 4 -7X0488 0.76 iia 102 161 02811 0211-05¢16AWG-UOBKB-06 5 7X0488 0.76 1a ma ise 02812 _0211-06C16aWG-UoBKe-06 6 7X0488 0.76 aaa wai _229 02823 0211-070 16AW6-UOBKE-06 7 7x04 0.76 aaa wa 239 02814 0211-08C 16AWG-UOBKE-06 8 7x04 0.76 nia 1a 207 02815 0221-09C 16AWE-UOBKE-06 2 -7X04a8 0.76 152 147338 02416 0211 10C16AWE-VOBKE-06 10 7X 0088 0.76 152 159353 16 02417 palT-12C16AWE-UORKE-Os 12 -7X04a8 0.76 isa iba 402 + 02418 0212-15C16AW6-UOBKE-06 1 7X0488 076 152 yea 486 02819 0212-16C16AWE-UOBKE-06 16 7X048B 076 152 yer 512 02620 _0221-19C 16AWG-VOBKE-06 19 -7X0488 0.76 152 0579 02421 0212-206 16AW6-UOBKE-06 2 © 7X048B 0.76 152, 200 61s 02622 _0211-24C16AWG-UOBKE-06 247X048 0.76 203 23.1 766 02623 0211-25C16AW6-UOBKE-06 2 7X0488 0.76 2.03, 231790 02424 0211-27C 16AWG-UOBKE-06 2-7 X0488 0.76 203 236 838 02425 0211-300 16AWG-UOBKE-06 30 7X04a8 0.76 2.03 2a 913 02426 _0211-37C 16AW6-VOBKE-06 37 7x0488 076 203 26.2 1083, 02427 0221-48C 16AW6-UOBKE-06 48 7x04e8 0.76 203 298 1361 02428 _0211-61C 16AWG-VOBKS.06 el 7Xo4e3 0.76 203 32.4 1668 Te] oar WEST Ce Tonaio ‘Grand | Tesoaton ] Wena voce | Apes | Aner Duaeter | times | “themes” | 0.0. | Vici awe | na Nex [em oo vm _| aikm 92429 0217-020 14AWG-UOBKE-O6 2 7xoss a4 1a 1316 02430 0211-03¢ 4AW6-UOBKE-06 3 7XoIs 124 uaa ua ae 02431 0211-04¢14AW6-VOBKE-06, 4 7X05 134 14 13.0261 02832 0211-05¢144W6-UOBKE-06 5 7Xo85 114 152 15.0340 02833 0211-06C14AW6-UOBKB-06 6 7x0815 aa 152 163403 02434 0212-076 14AWG-UOBKE-06 7 7X05 144 152 2419 02435 _0211-06C14AWE-VOBKB-06 8 7Xo0615 114 132 17488 02836 0211-09C14AW6-UOBKE-06 9 7X0e1s 114 152 ine 557 02837 0211-100 14AW6-UOBKE-06 107X065 11d 152 205 573 1a 02438 0211-12C14AW6-U0BKE-06 a 7Xoes 14 152 212 659 02639 _0211-15C14AW6-UOBKE-06 137X065 aa 203 245655 02440 0211-16C 14AW6-VOBKE-06 we 7X0eIS 1s 2.03, 245 901 02641 0212-190 14AW6-VOBKE-06 197X065 aa 203, 25.8 1021 (02842 0211-200 14AW6-UOBKE-06 2 7X06 114 203 27.2 1088 02843 0211-24C 14aW6-UOBK8-06 28 7X0e15 124 203 500 1258 0244 0221-25C 14AWE-UOBK8-06 27X61 14 2.03 300 1300 02445 0211-27C 1.4aw6-UOBK8-06, 2 7Xoe15 14 203 30.7 1382 02446 -0211-30C 14AWG-UOBKS-O6 3007x0815 1a 2.03 3171504 02447 _0211-37C 14aW6-VOBKS-06 37 7Xoe1s 14 203, 3421798 O2de — o22}-48C LaAWE-UOBKE-O6 ae 7x0e1s 14 203 392-2278 02649 0711-61 14AWG-VOBKE-06 1 7X0s15 114 279) 4422951 + Non THAW size, complies wih NEMA WCST. Suu MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS TYPE TC (UL) PVC INSULATED MULTICONDUCTOR SHIELDED CABLES Sie | over WESC tase ondecors | Swenasx | Tmasaton | Wominalvaca | Aperon | Approx Diameter | thine: | theees | "Oro | Wenn awe | no Nooxtem | rm em rm_|_ Kasim 02450 O21) G2012AWG UOBKE C6 2 7x07 114 14 122 24a (02451 9211-03C12AWG-U0BKE-06 3 7Ko775 11a aaa 129289 02452 _O211-04C12AWG-UoBKB-06 4 7x0775 114 ase 149 366 02453 0211-05C12AW6-U0BK8.06 57x07 114 152 ws 488 02458 0211-06C12AWG-U0BKE-06 6 7x07 114 152 v7 (02455 211-07C12AWG-UOBK8-06 7 7x07 114 12 we 542 02856 0211-08C1L2AWG-UOBKE-06 8 7x07" 114 152 192 629 02857 0221-090 124WE-U0BKE-06 9 7X0778 114 152 206 721 02458 021-100 12AWG-U0BKa-06 yo 7x0775 114 2.03 798 12 02459 0211-12C12AWE-UoRKE.06 wm 7xXo77S 11a 203 21 OL 02460 0211-150 12AWV6-U0RKE-06 wy 7XO77S 114 203 267 1106 02461 0211-16C12AWG-U08K8.06 we 7X0775 1a 203 267 1368, 02462 0211-390 2AWVG-UDaKS-06 19 -7x0775 14 203 261 1326 (02463 0211-200 12AWVG-UOBKS-06 2 -7X0775 1a 2.03 2937 a7 02463 0212-240 12AWG-UOSKE.D6 2 1X0778 11a 203 328 saa 02465 0211-250 12AWG-UOBKA-08 2 7X07 1d 2.03 328 1700 02486 0211-2701 2AW6-UOBKE-06 27 7XKO7S Lae 2.03 33.6 1812 02487 0211-300 12AW6-UOBKA-06 3 7KOT7S Lia 203 347 a7 02468 0211-370 12AWG-VOBKE-06 37 TXOT7S 114 2.03 brs 2373 02469 0211-40C12AW6-VOBKE-06, aa xo775 114 279 445 3160. Bae | over WERE Cole Cendicors | Stantik | insdaton | Wommal nae | Aaprox | Aaron Diameter | theres | theses | “Oro | Weigee awe} Wo Nooknm | nm ron fom__|_ Kavi 02470 __0211-02¢ 10AWG-UOBK-06 2 7x097e 114 1ae 34 320 02471 0211-036 10AWG-UOBKE-06, 3 7X08 114 152 150 ae 02472 0211-040 10AWG-UOBKS-06 4 7AO97T@ 114 152 3483 02473 0211-0SC10AWG-UOBKB.08 5 7x0978 114 132 79583 02474 _0211-06C 108W6-UOBKE-08 6 7x88 114 1s2 195689 02475 2iT-O7C10AWG-UOBK8-06 7 7X0978 14 ase 195729 ©2476 0211-08C 10AW6-VOBK-cb 8 7xX0978 11a 12 212885 02477 0211-09C10AWG-UOBK8-06 9 7x0978 114 2.03 238 1023 02478 0211-10C 10AW6-VOBKE-06 yo 7X0978 114 2.03 25.8 1062 10 02479 0211-12C10AW6-UOBKB-06 we 7Xos7a 11a 203, 267 zr 2480 0211-15C10AWG-UOBKE.0s as 7x0978 14 2.03 295 148s 02461 0211-166 10AW6-UOBKE-06 1% 7X0978 114 2.03 295 1573 02482 _0212-29C 10AW6-UOBKE-08 yw 7x0978 114 2.03 3111799 02483 0211-200 10AW6-UOBKA-06 200 7ko0a7 114 2.03 529 1916 02488 0211-24C 10AWG-UOBK-06 24 -7X0978 114 203 364 2229 02485 0211-25 10AWG-UOBKe-06 2 -7x097a 114 203 364 2310 2486 0212-270 10AWG-UOBKE-06 27 7x0978 114 203 37.3 2466 02687 0211-30C10AWG-UOBKE-06 30 7Xo97@ 144 2.03 306 2702 02488 _0211-37C 1OAWG-VOBKE.06 377x098 114 2.05 418 3261 INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPETC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED Temperature range - 40°C to + 90°C Specifications: UL1277, ICEA S-82-552 k= = TYPE TC (UL) 600 V MESE 2010 Application © Conductor @ Insulation © Pair Colour Code © Triple Colour Code © Pairs/Triples Twisting © Assembly © Jacket Can be used in cable tray, conduit or direct burial application for instrumentation / process contro in dry or wet location Tinned copper to ASTM 833, stranded to class-B/ class-C of ASTM B8 Flame retardant XLPE to ICEA $-82-552. UL rated VW-1 conductors. White and black with pair number on white conductor. White, black and red with triple number on white conductor. All pairs / triples are twisted to counter electromagnetic noise, ‘Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary and the entire assembly is covered with a polyester tape if required Extruded black PVC as per UL1277, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and maisture penetration. Note: Special jacket material ( CPE) can be supplied on demand. 55 56 4S MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPETC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED PAIRS SHE] bar WESC Caer fe] San Viena aa | aren | Baron ‘eter Thies: | 0.0. | veh wer |e. Nea a | oe Tisis —DiaFOTPTOAWG-UGBKE a 7 —7x0366 Ta Te 6 o1sis—012402P1AAWE-VOBKA-O6 2 7x03R% ane me uo 011s 0124039 18AWG-LoDKeas 3 7x0386 aaa 12310 o1s16 ——O1za-o4P1aAWE-UORKE.A6 4 7x0386 132 147198 o1si7 —_ol2eagPi@awG-vonKeae 6 7X0386 hse 169258. O1si8 0124-06? 18AW6-UOBKE-06 8 -7x0386 1s2 we 510 oisi9 _o12412P1aAW6-UORKeo6 2 7x0386 2.03 zi #5 de 01520 o124.16P1BAWG-UOBKEAS 1% -7x0386 203 248595 0152] 01242 18AWG-UoBKE-06 2 7X0306 2093 m2 70 ose 012624PL€AWG. UOBKE.06 247x038 203 29320 03523 012432?laaw6-LoBKeG6 52 7x0 386 203 5321000 01524 012436P18AWo-UODKRG6 a6 7X 03R6 203 3491180 01525 0124-40? aAWG-UoBKEas ao 7x 0386 203 366 1260 1526 o124.50e1sAW6-uonKe-o6 50> xo386 203 4031595 sae] om WESC Co a ‘rina Jacket] Approx | Areres Thine: | "00. | wet wey | na, = r_| Kon D159 0124 SIP IGAG-UEAKE 0 T Ti a4 75 01528012402 16AW6-UOBKE.GS 2 aa wos 01529 0124039 6AWG-UoBKO.a6 3 152 149200, 01530 O124.04PL4AWE-UORKE.O6 " 182 16028 Digg _oizaasergawe-vonKeos 6 132 ies 330 a1s32 124 08P1eAWG-UDBKB.O6 e 1s 1s 0 ae 91532124 12PYEAWE-UOBKE-OG 2 2.03 m2 bls (1534 1Z4-16P16AWG-U0BKS-06 % 203 22780 01525 _012420P16AWC-UORKRde 2 203 299935 1536 0124-24PT6AW6-U0BKE-6 4 2.03 3231090 03527 —_o1a-2P6aWG-UeRKeoe 3 203 dee 1395, 01538 012436P16AWG-UoBK8.a6 36 203 38s 1880 03539 ___0124-40P16AW6-UOBKE 05 2 2.03 04 1695 aaa WERE ate fain] Seana | Traian | asia nce | Appa | oan sioner | thekres | Toran: | 00. | woah wer |. Nexo | em = re] kon Digi DIR IPIAAWG VOBKE D6 7 —Wx0s7s 076 Te 37105 1st 0124-02 14AWG-U 0BK8-06 2 9x03 O76 asa wi als oii 012403P AAWE-U OB K-06 319x093 07% 1s 7520 ise) 124.04 14AWG.U OBKE-06 4 19x37 076 132 aso 1401544 0124069 14AWE-U OKO & 19x0373 078 203 20320, ‘1845 0124.08 14AW6-U 0BKE-06 8 19X0373 076 203 42S Oise 0124-12P 1AAWC-U OK 2 19K0373 078 203 27885 o1se7 0128-16 14AWG-U 0BKE-06 ae 190373078 203 324 110 01342 0124 70P14AWC-U OKE de 2 19037078 203 3571365 01549 124-24P24RWG-U OBKE-06 2 skos73 07h 2.03 387 a60s 01550 __0124:30P14AWG.U OBK8.08 5019x0379 076 203 4271950 So MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPETC ) XLPE INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED TRIPLES TE] oar eo Wain] SeanuX | rasan] Nonmal sae | Apo | Arron aneer | eines | theines | "00. | weet caer | Wo Nexmm | “mm 0 imo_| kok BSS — BET TTA TOT TE Trae — ase Tr 77 oiss2 oizeazTzBAw6-UoBKe-o6 2 7x03 abe sz 145370 01ss3_al2sasTieawe-Uo8Ke-06 3 7x038 Osa 152 ss ae Oise or2¢asTieawe-UoaKe-06 4 7x0385 O64 152 6735 01555 0124 06T1BAWG-UOBKE-06 6 7x038 Ona 152 203380 01556 -Ol24a8TIBAW6-U0BKE-06 8 7X 0386 Oe 2000 a ats 20 01557 gizsizTisawe-UosKeos «22-7 0386 © 203 25655 01ssa«O12416TIBAWG.UOBKE-06 «te «7X0386 OA 203 29 630 01559 olzaz0TieAw6-U0BKe-0¢ «20S 7 KOH OA 293 we 990 01560 e12é2eTLBAWG-U0BKE-06 2870386 Od 203 355155 Ois6i —ol2aszTaeAWé-UoBKe-06 327X388 OM 209 4031475 o1ss2 __aleaasTieawe-ussKeos 367X086 Od 203 42s 1635 Se] tee WERE Coe Wiles] Svan | talon owen Giaeer | teins ‘went cawer_| 0, Nexen | am Kote D156) D1ze-oITIGAWG-VOBKE-DE T7048 0.64 01564 oizeaeTisAW6-UoBKe-06 2 7x04 os ao 01565 012403 T26AW6-U0BKE-06 3 7x0468 Oat 265 01566 o124aeTusAW6-U0BKE-06 4% 7x0 064 335 01567 _ol2aaeTieawe UoBKe 06 é ost 510 01568 oleasTigawe-Uoake-06 a asa rc 6 01569 olzel2Tieawe-UoaKe-o6 12 oa eas 01s70 ol2el6TIGAWG-UOBKE-06 © 16 ash 1100 01571 o12420Tieawe-uoeKs-06 20, 064 a0 01572 o12e2aTieAwe-UosKe-o6 24 0. 1955 a WESE Cabs Ties Teslaon Reson | fom ‘eenst 00, | waht awa] na ‘mm mo_| Kan DISS — OTRO TTAAWE TOOTH DE 1 Ista —o76 vos bs oisraoizeazriawe-UoBks-06 219x083 078 1s 205 01575 _alzaasTiaawe-uoaKe-o6 319x033 078 wy 370 “ oisie — o1zeaaTi4awe-Uonke-os © a9x0s3 076 ns 5 01577 alaea6Ti4awe-UoaKe-06 6 39x03 076 za ns ogre o12+asTrsawe-UoBKe-o6 8 19K0373 078 0 tes 01579 alzaaTisawe-voBKe-06 2 19x0373 076 345 124s. 01880 olatenisawe-U0eKe.06 © te «19X0373 O76 392 ans Oise) __oizaznrraawe-uoaie-se 2019x0373 O76 32165 57 58 6S un MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPE TC) XLPE INSULATED MULTI PAIR / MULTI TRIAD OVERALL SHIELDED Temperature ran ge - 40°C to + 90°C Specifications: UL1277, ICEA S-82-552 Application : © Conductor © Insulation © Pair Colour Code © Triple Colour Code TYPE TC (UL) 600 V MESC 2010 Can be used in cable tray, conduit or direct burial application for instrumentation / process control, in dry or wet location. Tinned copper to ASTM B33, stranded to class-By/ class-C of ASTM B8. Flame retardant XLPE to ICEA $-82-552. UL rated VW-1 conductors. White and black with pair number on white conductor. White, black and red with triple number on white conductor. ‘© Pairs/Triples Twisting All pairs / triples are twisted to counter electromagnetic noise. © Overall Shielding © Jacket Note: Special jacket ‘Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary and the entire assembly is shielded with aluminum polyester ‘tape and a tinned copper drain wire. Extruded black PVC as per UL1277, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration material ( CPE Jean be supplied on demand. Sn MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPE TC) XLPE INSULATED MULTI PAIR / MULTITRIAD OVERALL SHIELDED PAIRS SHE] Grae ESE ae Pairs | SwandiX | Tsuaton | Werinaljnaeet | Approx | Approx dameter | thickness |" thelness | 0.0.” | Weight owes | Wo. Nox mim mm _| Kank D240 — —DPRT DIPLO PoORE De 1 7x0386 Ta 65 tee czeesznis WU cee ae 2 7x0386 ns us 2491 0224-08P1AAWG-UOBKE-06 3 7x03e6 so 02452 0226-04P1BAWE-UOBKE-06 4 7X0386 1475 02493 0224-06P18AWG-UOBKE-96 6 7x0386 19255 02498 0224-08P18AWG-UOBKE-05 8 7x 0386 a9 308 ones 0224-12P8aG-UOBKE-O6 127 X03 pi 47 Fr 02496 Oa24-6PLAAWG-UORKE9S 1k 7 X0386 2858 02497 o224-20P1eAWG-UOIKEDS «207 X0386 72695 o2a9s czaezaPiaawe- UoBKBOs 247X036 203 eos 02499 0226-92P180WG-U0IKE0S 327 X0.386 332 1020 28000224 36PI8AWG-UORKB-06 36 7 Ka388 392s 02501 oa24-40P18BWE-UORKB-O6 40-7 X0.386 366 1230 2502 __o224s0PeAwG-UoBKe6 507 X0386 4031480 Se | Oraer ESE Code Pars | SeanaeX Tp | Approx ‘dameter 0. | weight wwe) | Ne. Node smm_| ont Bases 454 OIPIGANG UOOKE 6 1 7 x008 a4 a 02504 0224-02P16AWG-UOBKE-06 2 70408 300 02505 _0224-03P16AWG-VOBKB-06 3 7x0406 yer 360 02506 0224-04P 16AWG-VOBKB.06 4 7Xo486 16025 02507 0226-06PL6AWG-UOBKE-6 6 7x04ee 15336 2508 0224-08PL6ANE-UOBKA6 a 7xoae8 as 400 02509 0224-12P6AWG-UOSKB-06 127 X88 22 wo Fra 02510 oa2eGPIGAWE-UORKE9 = 7 XB 2a Ks 02511 0226-20P16AWGUOSKEOS «207 Xa.ate be 90 02512 0224-28P16AWNG-UOBKE0 27 XOMBR 203 3251070 02513 0224-32P1GAWG-UORKE-D6 «32,7 KOMBO 2.03 366@ 1370 02514 0224 36PL6AWG-VODKEDS 387 XOMBH ws 2.03 ans 1s 0251s o2eOPL6AWEUORKED 40 XOMBA Oe 203 aoa 1660 ‘wae [er THESE Coe airs | SwanisX | osulaton | Norval jacket | Approx. | Approx. lameter | thickness | tienes | 0.0. | Weight wwe) | no. Nexmm | mm ‘om ork e516 —_o224 01P GANS DOBBS 1 Texoss 076 Te 715 02517 0224-02P 4AWG-UOBKB-6 219x037 078 as2 220 02518 0294-09P14AC-UOBICE 06 3 isxos 076 use 280 02519 0224-08PL4ANG-UOBKE-06 & 19X03 78 sz as “ 02520 0224-06P 1AAWG-UOBK8-06 6 19K037 076 203 sis 02521 0224-08PL4AWE-UOBKA-06 8 19X0373 O76 203 630 02522 0224-12P14ANG-UOBKe-DE «1219 KO373. O76 2.03 #70 025230224 6PIAANG-UOBKeO$ = 619K 0373. O76 203 3221105 62524 0226-20PLAAWG-UOBKAOS ——«20—«19X0379 876 203 3551340 e255 zz 2apraawG-UOBKeoe 24190873076 203 365 1565. So MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPE TC) XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED TRIPLES Size] rae WESC Cote Wes] Stands X | Tesaton | Wortnal aekel | Approx [Aparor Gdameter | thieiness | ticeess | “00. | Wels cower | no. Nom | "mm nn rim_| Karke Wes2_ aR TTOAWE-UOBKR-TE T 7x 0386 068 Tae e280 02527 0226 02T18AWG-VOBKE-ob 2 70386 cee 152 4570 02528 924.09TIBAWG-UOBKB.05 3 703% Oe 1s 13310, 025290224 0eTAAWG-UOBKB.O6 a 0.64 182 167255 2320 a224-06T1AWE-UOBKE-08 é oe 132 23 350 bass o2a4oeTasAWe-VOBKE.O8 8 0.4 203 ma 470 28 5532 oazatzTIBAWGUOBKGOS 32 ose 203 5 is 02523 aaaNABTIAAWG-UOBKEOG 16 0. 203 a9 as 2538 0224-2071 BAWG-VOBKEGS 20 0.84 203 ne 970 02535 (Opeazayiaawe-uosKa-cs 247X038 O64 203 355 130 02536 gaauaaTiMAWG-UOBKBOG «327 X0306 OHA 203 431400 02537 ____o224-soTaaAWG-U0BKEce 36 7 X0386 064 2.03 4251600 SE] oraer WESC Cade Wb] Stands X] Tealtian | Wornal eker ameter | thekness | Wleeress cower | no, Noxrmm | mm ‘a w2s38 _oa24 DITIOAWG-UOBKEDS T 064 Tae 89 100 2539 02a4-02TGAWG-UOBKE-06 2 ose asa ase as t2sa0 —_0224.02TBAWG-UOBKE-06 3 7Xoam 064 132 yer 5. bess) baga-naTaAWG-UOBKE.06 4 7x08 oes 152 162325 ne 02582 ——224-06TABAWE-OAKE-O6 & 704s oes 203 2a 508 basas—_0224-08TIBAWG-VOBKE-O5 8 08a 2003 me as b2sae —ozaeeiaTieAWG-UOBKE-Ge 12 064 203 231950 bases G24 BTIBAWG-UOBKRCE = 167 X0aRE Oe 203 3291080 n2sae 0224 20T16AWE-UOBKBGG «207 X0408 Oe 203 362 1300, assy oa2naeTasaWe.UoBKece 247X048 O68 203 3321520 wee] ae WESC Cede Tne | Sands] Teton | Womsnar ket | Approx | Aparon Giameter | tesness | thickness | "80. | Weis tawer | no Noxon | "nm es rim_|_ Kank Tess oa] DITARVE-VOBEB GS T—W9x0373 76 Te 103390 tasae 0224-0271 AAW6-UOBKE-OS 2 19K0373 076 ase aes 200 asso 0224-027 4AWG-UOBKE-0b 3 1xea 076 se 197375 ne ASSL OnBH-OATIAAWE-UOBKA.OS 419x033 076 2.03 2s a 02552 0224-06T14AWVG-VOBKE-O6 & 19x0373 076 203 ara no 2553 0224-08TAAWG-LOBKE-OS 8 19K0373 076 2.03 20 a5 oasse —oa2a2TiMaWe-UOBKEOE «12,29 073 O78 203 34s us ness oa24-1gTAAAWG-YOBKG.0G 16 290373 076 203 322 srs INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPE TC) XLPE INSULATED MULTI PAIR / MULTITRIAD INDIVIDUAL & OVERALL SHIELDED Temperature range - 40°C to + 90°C Specifications: UL1277, ICEA S-82-552 | TYPE TC (UL) 600 V MESC 2010 Application © Conductor # Insulation © Pair Colour Code © Triple Colour Code © Pairs/Triples Twisting © Individual and Overall Shielding © Jacket Can be used in cable tray, condult or direct burial application for instrumentation / process control, in dry or wet location. Tinned copper to ASTM B33, stranded to class-By class-C of ASTM B8. Flame retardant XLPE to ICEA S-82-552. UL rated VW-1 conductors. ‘White and black with pair number on white conductor. White, black and red with triple number on white conductor. All pairs / triples are twisted to counter electromagnetic noise. Each pair / triple is shielded with aluminum polyester tape and a tinned copper drain wire, for maximum electrostatic and crosstalk rejection.All pair/ triple sheilds are electrically isolated from each other. Individually shielded pairs / triples are cabled with non-hyarascopic fillers if necessary and the entire assembly is shielded with aluminum polyester tape and a tinned copper drain wire Extruded black PVC as per UL1277, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration Note: Special jacket material ( CPE Jean be supplied on demand. él 62 a Sie MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPE TC) XLPE INSULATED MULTI PAIR / MULTITRIAD INDIVIDUAL & OVERALL SHIELDED PAIRS SHE | Oraer WESC Code Pars | Svantex ‘eorox. | Aserox lameter 0, | Welsh cawar | No. NoXrmm rm _| Karki oaies ovaa-a7PiaaWG-UoBKace 2 7 x0.386 12450 foni4s ——oa2nozPienwc-vonKeos = 3-7 X0.386 35s 04147 onzaonpieAWe-UOBKe-o6 4-7 X0386 Bo 25 onise —oeze-oupieaWG-U0BKe-os = & «7 X0.306 v7 300 18 Gaiso kee 12P2eAWG.UOBKE-Ob = 127X386 232580 Onis) ——OK2A-IGPLEAWG-UOBKE-06 167X386 20705, ois2 oxza-20P2eAWG-UOBKE-06 «20-7 X02386 2s ats 0415s aaze-zapzeaG usexe-ce 34-7 X0.386 x08 990 of1s¢ —oszaszPIBAWG-UOBKE-OS = 32,7 XO0386 3493250 omiss orza-sgpieawG-uoaKe-o¢ 36 367 2385 Oise osza-40PIBAWG-UOBKB-O6 40 3853520 Onis? ___oe2a-50PlBAWG-UOBKE-O 50 25 1885 Sue Oraer WEST Cade Pais] Sands | Tnslaion ameter | thickness cawey |e. axon | Bass ONOIPLEAWG VOEKEGE 37 Koaba- 0.00 (4159 DA2ROSPIBAWG-UOBKROS = 7xOMBE Oa mice 0424-04 2¢AWG-UO8! & 7x08 ons O16) OF2A.OGPLEAWG-UOBKE-06 G7 KOM. oarse —ovzaenrneawe-uoske-os «7 X0ABs 68 6 On16s—baandaPlEAWG-UoNKeO: 270A oaise ——oeza-yupieawe-uoaKe-ss 16 7X04. 203 303580 ‘nibs D424 20PI6AWG-UOBKADG 20. 7X04BE 0. 203 312 a0 bales ——ocza2arncaw-LaRKe-ce 24 «7 XOMBA Ae 203 33a 305 ons? oeaa-szpieawe-UomKe-cs —32-7XGABE ks 203 3831630 os1ee 042.26 24AWG-UOBKE-O 36 aaa 203 4031865 O16 0474-40 gAWG-UOOKE-9 40 ye 20. 4232045 SE] trae WESC Cate Pais | Swans | Wissen | Nominal jacket | Approx | Aoprox ameter | wickness | thickness | 0.0. | Weight cawer | ne. Noxmm | wm nm rmm_| Kater ‘DaIT) GAR 2PIARNE-UORE DS F_iexan77 076 332 Tee 255 oci71—oaztasPianing-uaBKeds 3 x0373O7% 132 1330 04172 0424.04 14AWG-UDBKB.06 419x033 07% 152 195405, 941730424 06P 4AWE-UOBKE.O6 & 19x0373 07 203 28 605, 1“ 06174 O4288PIAKWWG-UOBKE-06 8 19x0373 07% 2.03 21745, 06175 O42ePIAAWE-UODKEOS == «12«19X0.373— 07 209 2371045, on% —ovzatenr4nWG-UaeKe.cr 16 «9X 0373 076, 203 bas 3335, on77 —otza-zopnaAWe-UoBKess 20, 9KOR7S OE 203 S70 1635, oar7e __0a2a.2arranwG-U00K8.06 249X933 0.76 203 4012910 “Swe MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPE TC) XLPE INSULATED MULTI PAIR / MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED TRIPLES sae] er TERE toe "eles | Sean | easton [Rone | Aner | ee Somer | tices | onamess | 0." | Wea ows | me im oa | om | om Sai — aC TTONE WOEKEDS — 7 — 7 ote 9 setae 3 yheoee ie Bs mast frreaee aS bates o Fkeee 1 nea coe ee eee = os184 0424-12 T1BAWG-UOBKE-06 w 7X9.386 203 aT 740 oaiss —Saaessrisanevostose te 7030s re he osise Srasasrisane-wenese 2079380 2 as Sner — Staseerigawevoenece 347388 OBS ota cuseazrisancomese 3970s pasts ae] ber WSC tome Wows | Semax eae ‘Aone ‘snes ower | no een en Sas TTT ORES i gasp cuaeosrisane vosmese «3 7woses, tai Susy otseosricanevosnees tres 1 puseeesesstionwe.tgorses og 7 eeass 20s x¢ © (ouiss—soustestienwevosrese 7x ee bos aise Sterasrisans-tosiece xe 7a is stiseoweaoriomvevestess 20 7x0se8 303 ee ee 7 | ar TREE Fae] Seas on | Roark ak inwor [ne eee Lee om Sue casmiumevonnnes 3 dekaara aoe OR oeiwo—Geaeosrisans-omesce 90393 S98 tos Gaon pteeaeriaaneteorgs og iexega eae ee vere ouaeosrisanevosnecs «9033 ove yo ee 0 sues ouesariaweueskegs az a9xea73 oe is er dae So MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPETC ) PVC INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED Temperature range - 40°C to + 90°C Specifications: UL1277, ICEA $-82-552 a TWPE Te (UL 600 V MESC 2010 Application Can be used in cable tray, conduit or direct burial application for instrumentation / process conte, in dry or wet location. © Conductor Plain copper to ASTM B3, stranded to Class B/ Class C of ASTM BB. Insulation Flame retardant PVC rated 90°C as per UL 1582. UL rated VW-1 conductors. Pair Colour Code White and black with pair number on white conductor. Triple Colour Code White, black and red with triple number on white conductor. © Pairs/Triples Twisting All pairs / triples are twisted to counter electromagnetic noise. © Assembly Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary ‘and the entire assembly is covered with a polyester tape if required. © Jacket Extruded black PVC as per UL1277 oil and sunlight resistant, passes flame test as per [EEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration. MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS ( TYPETC ) PVC INSULATED MULTI PAIR / MULTITRIAD UNSHIELDED PAIRS. ae — ee eels] aoe [Ses [es [or | Se tee oe Eeseeeee ) Bs Ee ee a oe Remmegees Re SBR ce Sesame Se am SULABPLEANE UNE OE Aa ae oag og pag ap noes | aE Ore ERC ae Pais | Sosa ‘prox. | Aare ameter 00 | went awe) No. esx w_| Kat ase THGTALGAWE UEBTS-Te T—Txosee 076 Ta e380 21597 aun c2PLGAWe-UoRKG-c6 2 7x0a 076 182 ies o1see ori1-e3Pteawe-UoeKe-o6 > kaa O76 use ie 5 recy a301-o4PLeAG UDBKE- 26 4 yx0me 076 use 03a 1608 ou obPt6ANvG-UOBKE-36 © 7xoaee 076 tse e390 1st Gui abPteawe-UoeKe-o6 8 pxoae 076 ise 2a aes 6 ‘i602 oni-tzmieAvG-UoAKe- 06 2 }xoawe a7 203 Be 740 16a ax11-26P16ANve-UOBKO.06 37 koase Oe 203 20 ‘o1soe oui 20P6AWve-UOBKE-c6 7 7x08 06 203 zo as. ‘oxéos 0211 24Pt6ANG-UOBKE 86 7x08 076 203 Bea ues on608 0311-32P16ANE-UOBKO 26 3 7x0am 0% 203 37908 1607 sri a6Pt6awe-U9BKE.06 Se 7koae8 O76 203 a 1080 eo L-AOPL6AWG-UOB G06 et 409076 ans _zoa0_| oe oan THESE Coe Pas | suman TWerina Jacket | Anwox | Awe ‘aren TWeiness | 0D | wet aes a, NaKron et ne_| Ravn o1610 ‘0111-02P14AN6-UOBKS.05 2 wos e tse 3e7 a0 ous Ou11-03P144Nv6-UOBKe-06 3 woo Lie use 204 3b oz O21. 04PL4AWG-UDBKG OG & wean Lae 20 aaa 30s “ ores o211-GbPI4AWG-UDBKE-26 ® yexoas a4 203 2a 60 ouuis ounaznieane-uosKe-a8 19033 Le 203 ba 195 ors o111.26P14AN6-UOBKE 06 ae soa 4 203 3831830. 017 0331-20140 UOBKE- 36 20a 14 203 23 1a8s Sun MESC INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPETC ) PVC INSULATED MULTI PAIR / MULTI TRIAD UNSHIELDED SREY ower WESC Cae ‘Semisk | Tesion | Nenalanaat | Amon] Ree ameter | wehwes | Tidoes | 0.0. | wen wey | na Nok | nan = | Koken Trois TOT TARWE TUBES 7Xb386 876 Tt ae 35 a1, suit-osrieawe-voaxe06 7xo38 876 asa ass 200 oat 121-067 DAWG VOB 06 7x030 076 ase 79 wo 01622 orn cerieawe-voBKs-06 Tease 036 203 294s fle 0121-08T28AW6-U0BKE-06 7038 076 203 2a Be uses 131-22" 1eAWE-U0BxE-06 Tress 076 209 seo 162s oir 26rseAWE-vOBKE 06 703m 076 203 31s 0166 orr1-20T18aW6-voBKs-06 7xa3e 078, 203 385125 107 enL2arigawe-UoBKe-06 Tease 076 203 es mo 128 0153-32788 UO 08 prose 076 203 yee aE] oer WESC ‘Seaesx | Tnanion | Womiarinont | aasror Sameer | ices | Theees | "00. cawrey |e. Nexen | 7 mn 1430 ‘nL LaeTIeAWE-UOBKE-O6 reese 0.76 ase 168 ies {0121-037 24AWE-UDBKE 06 Frese 076 ase v3 162 OTIL-OdTBAWE-UDBRS 06 eee 076 ise 5 % 183s orn a6TasaWe-voBK06 Teese 076 203 m9 01635 0311.127364W6- YOR 06 2xaae 076 203 dross oleae brivaerieawe-uonce-o6 7kaame 076 203 ssa ae 163? oy31-20T1eAWE-V0B8-06 yeaa 078 203 bao 1920 163 O1L-24T L6G UOBKE DS pxeame 076 203 4231905, SE oar WER cae ‘Semek | Tastes | Wenkarsvamt | Amon | epon Ganster | ‘ices | Tiidaew | 00 | weit wer | na. eokmm | “rn = me_| kann rrr THIL-aTTaAWe TOES 190377 Lia Te Ty 7s rey (0121-027 34AWE-UDBKE-06 aexoa7s ae 203 neo “ lena axes 14 203 aha to 16s axa aa 203 ws 9s isa OL LA6TA4AWE-UOBKE-O6 aexo37 a 203 Baa 1200 INSTRUMENTATION / PROCESS CONTROL CABLES TRAY CABLE 600 VOLTS (TYPETC ) PVC INSULATED MULTI PAIR / MULTI TRIAD OVERALL SHIELDED CABLES Temperature range - 40°C to + 90°C Specifications: UL1277 & ICEA S-82-552 | TWPE TE (UL) 600 V MESC 2010 Application Can be used in cable tray, conduit or direct burial application for instrumentation / process control, in dry or wet location © Conductor Plain copper to ASTM B3, stranded to Class B / Class C of ASTM BS # Insulation Flame retardant PVC rated 900 as per UL 1581. UL rated VW -1 conductors. © Pair Colour Code White and black with pair number on white conductor. © Triple Colour Code White, black and red with triple number on white conductor. © Pairs/Triples Twisting All pairs / triples are twisted to counter electromagnetic noise. © Overall Shielding Twisted pairs / triples are cabled with non-hygroscopic fillers if necessary land the entire assembly is tinned copper drain wire. © Jacket Extruded black PVC as per UL1277, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration. ided with aluminum polyester tape and a 67

You might also like