Versatilitlr l

Ground Mounting: Wall Mounting:


The AFL functons beautifully for lighting architecturaL facades and Because it is such a clean and s mple form, the AFL can be wall
walls, high level landscaping, sculpture, signage and flags. Several mounted as a complementary addition to architecture. As a wall
ground-mounting options offer versatility and economy by providing mounted luminaire, the AFL becomes a versatile exterior and inte-
multipleJixture mounts wlth the added permanence and strength of a rior lighting too, When mounted on buildlng exterior walls, areas
stanchion. For areas where vandalrsm is a concern, we recommend around the structure can be economically illuminated, saving the
the Heavy Duty Swivel as added secur ty against tampering. Additional cost of poles. As an interior lighting rnstrument, the AFL provides
vandal resistance can be achreved with the polycarbonate lens optton. an ideal lighting solution for today's atriums and high ceilings, The
For locatlons where it is necessary to shield or contro the light source, AFL Barn Door system should be considered ldeal for precision
available options are the fully-adjustable barn doors and the fixed glare control in interlor applications. Where wal s or columns are
hood, which can be mounted along the top or the bottom of the lens. not available, the AFL can also be ceiling mounted.

iq..
*

: )i1.r

,:a:!|t\.

K m Lighting
7

Surface Mounting: Special Mounting:


For standard tree lighting from grade evel, the AFL is unmatched in By nature, a floodlight rs the classic example of flexibility in out-
performance. To accomplish the "moon ighting' effect, the AFL has door lighting. lts multi-directional aim ng abi ity provides for versa-
numerous advantages as a tree mounted lumtnarre. Because trees ti ty and fine-tun ng after lnstal ation The Kim AFL brings all these
vary greatly in proportrons and structure, a choice of three AFL beam features together wlth design coordinated mounting hardware.
patterns permits tailoring the light to the task. The "moonlighting" Twin lVounts allow expanded light coverage with highly flexibLe
technique requrres shielding of the down lights, whlch is easily ac- shaping of the comblned light pattern. The Twin l\4ount also a lows
complished with the Barn Door option. Because the AFL frxture con- a combination of two beam patterns (AFL2 and AFL3) for lighting
tains a I the e ectrical components, no unsightly ballast box ls of taller buildings where a single fixture wou d not provide uniform
required at the tree base. The AFL Surface Mount screws directly light coverage from top to bottom. Sing e or twln Post Top Mounts
into the trunk or branch, with eectrica feed by conduit or outdoor a so provide a means for pole mounted area lghting.
cord. Surface \,4ount can also be attached to wood structures.

tF' it

\s

Kim Lighting
Procluct Structure
Fixtures with Standard Swivel
For high-wattage full slze Kim
Architectural Floodlights, contact
your local Kim representative.

See pages 12 through 15 for orderng information

FH
Barn Doors Fxed Hood

WM
Wall or Ceiling
[\4ount
WM1
Wall Mount
AFL 1, 2,3,4
with Standard Sw vel

J27N
Surface Mount
Junction Box

S de Pole Mount

J81
Archrtectural
Junctlon Box

TM2
Tw n Mount Side Po e l\,4ounl
Tenon

Po e wlth 2'pipe
SM2 size tenon by
Stanchion Mount Tenon Kim or others.

=
fr :t tr

Kim L ght ng
Procluct Structure
Fixtures with Heavy Duty Swivel
For high-wattage full size Kim
Architectural Floodlights, contact
your local Kim representative,

See pages 16 and 17 for ordering information

FH
Fixed Hood

AFL 1, 2, 3, 4 HDS
wiih Heavy Duty Swivel.

I
SMT
Surface l\,4ount Tenon
Pole Mount
Tenon

Pole with 2'pipe


SM2 size tenon by
Sianchion Mount Tenon Kim or others.

Kim Lighting
Important Features

Functional Beam Patterns.


The AFL was designed with
four beam patterns that best
accommodate the geometry
of most architecture and the
surrounding environment.
lnstal atrons of one or multiple
beam spreads will provide
complete versatility for exterior
or interior lighting See pages 8
through 10 for application
gurdelines.
AFLl
Vandal Resistant Construction.
A precision die cast housing with
extra-heavy wa I thichness gives
the AFL a rugged character,
Heat-dissipating ribs add body
strength while reducing internal
temperatures, thereby promoting
extended life of the electrical com-
ponents. Recessed allen head
screws are utilized in the swivel
and door frame assembly.
Added vandal resistance can be
achieved by specifying the
Heavy Duty Swivel.

lnstallation & Maintenance.


The AFL is shipped completely
assembled and prewired with
leads. Lamp installation rs done
by removlng fuuo captive al en
head screws. The complete re-
flector assembly is removable as
a unit, providing access to the
ballast. lhe hinged door frame s
held by a stop arm for easy lamp
installation and general mainte-
nance requirements.

Standard Swivel. Heavy Duty Swivel.


The ingenrous AFL standard Specifically designed for installa-
swivel is a compiement to the tions where rhe lixlure is accessi-
housing design. The swivel is pre- ble, mounted close to the ground
cision die cast with concealed and susceptible to tampering and
inrernal locking leelh. Locking vandalism. The Heavy Duty Swivel
adjustments are aI 7 .5' rntervals is constructed of heavy cast alu-
and marks on the side of the minum with locking teeth providing
swivel are at 15o intervals. adjustability in 5'increments and a
Adjustments are made by loosen- full 360'horizontal rotation. The
ing the recessed allen head swivel mounts directly to a2' pipe-
screws at both ends of the swivel. size tenon, with heavy duly 3/a'
For added strength allle 1/2" stainless steel set point screws
N PS IVI mount, the aluminum provided to firmly lock the fixture in
swivel transitions to a heavy stain- place. The Kim SM2 Stanchion
less steel plate and nipple. Mount Tenon is an exceLlent
mounting option for permanence
and vandal resistance.
bee page r r ano ro.

Kim Light ng
Design Coordinated J-Box.
Kim realized that mounting the
AFL on a rypical outdoor junc-
tion box would substantially
compromise the AFLs' appear-
arce. Consequenrly. Kirr ir-
vented the Architectural J-Box.
It enhances the AFLs' clean
lines, allowing an integral transi-
tion between fixture and sup-
port. The Kim Architectural J-Box
is precision die cast in a miri-
mal cylindrical shape to match
the swivel flange. lt is fully gas-
keted and U.L. and C.S.A listed
for wet locatlons. The AFL
swivel firmly seats on the J-Box
and locks by an internal set
screw. The Architectural J-Box
also provides superior strength
as an above-grade-only mounting
device.

See page 13.

Barn Door Option. xt.


,t' l'le ' ,! {/ .ff"
.tl,r:'\
Barn doors are the most logical
and flexible way to control
*r, ii?,^A
glare without destroying effi-
ciency and uniformity of illumi-
nation. The AFL Barn Door ;&: a
'-
option is designed for outdoor
and indoor use. The hinged
doors lock in position and are
individually removable. Each
extruded door features anti- re-
flection baffles, and is mounted
to a cast aluminum frame. The
Barn Door option mounts to
any AFL, can be used with the
polycarbonate lens shield, and
may be conveniently added if
the need arises after installation.
It is particularly useful for
shielding the lamp in down-
lighting conditions.
See page 13.

Kim Lighting
ApplicaticDn Guide
AFL1 Horizontal Spot

General Guidelines. See pages 1 8 through 22


The AFL1 horizontaL beam for photometric reports.
pattern is designed to illuminate
surfaces lhat are more horizon-
tal than vertical or longer than
wide.The AFL1 is designed for
broad illumination with the fixture
relatively close to the lighted sur-
face. Recommended distance
from the lighted surface is 6'to 20'
depending on lamp and wattage.
Optimum aiming angle is 325".
AFLl

AFL2
AFLl

Facades-one to two stories AFL] in combination with AFL2 Walls.


for facades of varying height.

Signs- horizontal Parking-single rows along sides of building Shipping Docks.

Atriums-narrow Ceilings narrow. Courtyards- narrow.

Trees-very broad, Hedge Rows.


Fixtures mounted at grade
oron trunk above eye level.

Kim Lighting
ApplicaticDn Guide
AFL2 Vertical Flood

General Guidelines. See pages 18 and 23 through 26


The AFL2 vertical beam pattern for photometric reports.
is designed to illuminate taller
surfaces when grade mounted
or deeper areas when wall
mounted. ln general, AFL2
fixture spacing is less than AFLl,
but the beam reaches higher or
farther out. Recommended dis-
tance from the lighted surface is
6' b 2A'depending on lamp and
wattage. Optimum aiming angle
AFL2 is 45'.

-__:=::<
Facades-two or three stories
Signs vertical Ceilings wide
-:

Courtyards wide Parking-double row along

AFL2 in combination with AFL3


for uniform lighting of taller
buildings or objects.

AFL3
^"'ryfrry

Atriums-wide

Trees-vertical.
Locate fixtures
outside the
perimeter of
tree.

lighting.

Kim Lighting
ApplicaticDn Guide
AFL3 Horizontal Spot
AFL4 Oval Spot
General Guidelines: See pages 18 and 27 through See pages 1B and 31 through
The AFL3 and AFL4 spot 30 for photometric reports. 34 for photometric reports,
reflectors are very intense,
concentrated beams designed
to light objects which are a
considerable distance from the
fixture, They may also be located ffi AFL3 ffi AFL4

ffi(U p*********o***rry ffi ll ]ll


A- ll-- '-l.l = l'F,'
lfi-lA@
close to a building where the effect e****nrr*******ry
of grazing light is desired to show
surface texture, or to highlight
reliefs and projections. = ll s I

hmflfrmffiffirurrymmdmflmffid htrfirmrsffiWqgmtrtrmdodd
--E-
-

Facades - three to four stories where grazing light is desired Building Features
to show surface texture, or to highlight reliefs and projections,

Building FrjCal Point signage, Signs - where fixtures can be located a considerable Signage - on building
clocks or iocros. distance away. Barn Doors recommended,

Flags
30 -50
height

AFL4

Trees - tall with loose


foliage so light can
penetrate to the top,

Fountains - adds sparkle to water as a Atriums - ciown lighting from three


compLement to the underwater lighting. to four story level.

10 Kim Lighting
Fir<ture Specifications
Warning: Fixtures must be grounded in accordance with local codes or the
National Electrical Code. Failure to do so may result in serious personal injury

Cefiification: U L.Iisted (Ior 120,208,


24O and 277 Yoll only) and C.S.A certi-
fied (for 120 and 347 Voh only) for wet AFL 1, 2,3, &4 AFL 1, 2,3, &4
locations. WITH STANDARD SWIVEL WITH HEAVY DUTY SWIVEL
Housing: One piece die cast alu-
minum in a cylindrical shape with inte-
gral cooling fins over the entire length,
and .125'minimum wall thickness,
Concealed integral cast slip hinges
with stainless steel pins.
Door Frame: One piece die cast alu-
minum wiih integral cooling fins, .1 25'
minimum wall thickness, mates with
housing to create a continuous cylindri-
cal shape, Concealed integral cast slip
hinges allow removal without tools.
Stop-arm provided to limit door frame
opening. s/rc'Ihick clear tempered
glass lens is sealed to door frame by a
one piece molded silicone gasket. One
piece molded silicone gasket between Front
housing and door frame, concealed
when fixture is closed, Door frame Slips over 2'
secures to housing by two stainless Single Fixture pipe size tenon
Single Fixture
steel recessed captive allen-head (24/a' O.D. x 3lz"
E.P.A. 0.7 (45'ritt) E.P.A. 0.8 (45" titt)
screws. Four tapped and plugged minimum length)
1.0 (Face-on) 1.1 (Face-on)
holes provided for attachment of options. Weight 24 lbs, maximum Weight 25 lbs. maximum
Standard Swivel: Die cast aluminum
with internal locking teeth providing

f
7.5' adjustment intervals, Stainless
steel allen-head locking screws, bear- 63/i',
ing flange and lz' N PS.M. nipple.
Heavy Duty Swivel: Cast aluminum
with locking teeth providing 5'adjust-
ment intervals. %" stainless steel lock-
ing bolt, Two 7e'stainless steel set point
screws secure swivel to any 2" pipe size
Ienon. (2W O.D.x31/2" min.length)
BYz' l-
B%'

Reflector Assemblies: lnterchange-


able in all four AFL fixture types.
Specular Alzak@ aluminum optical
components mounted to clear an-
odized aluminum frame, Reflector as-
l_ L,
sembly snaps lnto flxture housing with
spring clips. HPS and MH medium
base sockets are porcelain rated 4KV Side Side
Electrical Components: Factory
mounted in housing and prewired with
leads extending from swivel. U.L. rec-
ognized components with high power
factor ballasts rated for -20'F starting.
Optional photocell internally mounted
with sensor on side of housing, '.5'
Finish: Housing, lens frame and
swlvel are Super TGIC Thermoset
Polyester Powder Coat Paint applied
\
over a chromate conversion coating in
Black, Dark Bronze, Light Gray or ../
White colors.
Aiming Range (May be limited )
Photometrics: Based on lndep- by selected mounting option as
endent Testing Laboratory (lTL) reports shown on pages 13-15)

Kim Lighiing 11
Fixture Ordering Information

{{w
See AFL2 Catalog
for 250 Watt and 400 Watt
AFL Architectural Floodlights.
Fixture and Option Ordering:
Factory installed wlth flush sensor on
Fixture must be ordered by a slngle side of housing. Caution: Use only
catalog number consist ng of Fixture
ln locations where adjacent lghting
Type, Eectrcal Mode, Frxture Finlsh,
will not affect operation of photocell.
Optional Heavy Duty Swvel, and
Se ect photocell with same lne vo ts
Optional Photocell as fixture.
A i additional components must be
Car. No. Line
',)or'"'"
Vohs
listed separate from the fixture order
number See pages 13-15 for Fixture: [fl'l / 150HpS j2O I DB-p / HDS / A-30 i-io'"
A-31 2o8v \
z* 1,4
p)
Standard Swive Options and pages
16 and 17 for Heavy Duty Swivel A-32 2aov. \54-?) l
Options A-33 277V. Sed.o'\J
A-35 347V
A I lamps must be rated for Fixture Type and Electrical Mode:
"Unrversal Burn ng Pos t on."

Clear amps are recommended for


optimum performance.
For lamp/ba ast nformation outs de
of the U.S.A. and Canada, please
consult your ocal Kim representative
See page 1I for U.L. and C.S.A.
cert flcat on for line voltages
isted below. AFLl AFL2 AFL3 AFL4 Electrical Data
Honzontal Flood Vertical Flood Horizontal Spot Oval Spot
Maxlmurn
Electrical Mode Electrical Mode Electrical Mode Electrical Mode S

120 70HPS1 20 B8 1.45


70 Watt Clear 208 70HPS208 88 0.85
High Pressure Sodium 244 70HPS240 BB 080
E1 / N/ed um Base 70HPs277 BB 4.75
ANSI 562 347 70HPS347 93 0.65
1 00HPS120 1 00HPS1 20 1 00HPS1 20 2.20
I00 Watt Clear 1 00HP5208 1 00HP5208 1 00HPS208 1.27
High Pressure Sodium 1 00HP5240 1 00HP5240 1 00HP5240 1.20
El7 Medium Base 1 00HP5277 1 00HP5277 1 00HPS277 110
ANS S54 1 00HP5347 1 00HP5347 1 00HPS347 0.85
120 150HPS120 150HPS120 1 50HPS1 20 2.BO
150 Watt Clear 2a8 150HPS208 150HPS208 1 50HPS208 1.60
High Pressure Sodium tao 150HPS24o 15oHPS24o 1 50HPS240 1.53
Ei7 N/ed um Base 277 150HPS277 150HPS277 150HPS277 1.40
ANSI S55 3a7 15oHPS347 15oHPS347 1 50HPS347 1.25
120 70MH120-M 70MH120-M 89 1.80
70 Watt C ear 208 70MH208-M 70MH208-M B9 100
Meta Ha de 240 70MH240-M 70MH240-M B9 0.90
ED17 Medium Base 277 70MH277-M 70MH277-M 89 0.80
ANSI M98 347 70MH347-M 70MH347-M 94 065
1 00MH120 1 00MH1 20 260
100 Watt Clear 100MH208 1 00MH208 1.50
[/eta Halide 1 00MH240 1 00MH240 130
ED17 lved um Base 100MH277 100MH277 1 15
ANSI MgO 1 00MH347 1 00MH347 0.90
124 150MH120-M 150MH120-M 150MH120-M 3.65
150 Watt Clear 2aB 150MH208-M 150MH208-M 150MH208-M 2.10
Metal Ha de 240 150MH240-M 150MH240-M 150MH240-M 180
ED17 Medium Base 277 150MH277-M 150MH277-M 150MH277-M 1.58
ANSI M102 347 150MH347-M 150MH347-M 150MH347-M 1.25
124 175MH120 1 75MH1 20 I.80
175 Watt C ear 1 75MH208 1.44
l\,4etal Halrde 24A 175MH240 1 75MH240 0.90
ED'17 Medium Base 277 175MH277 175MH277 0/B
ANSI \I57 347 175MH347 1 75MH347 065
500 Watt Maximum 417
Quartz T-4 Min -Can

Fixture Finishes: Cat. No. Color Color


Super TGIC thermoset polyester powder coat parnt BL-P Black LG-P Light Gray
applied over a chromate converslon coating.
DB-P Dark Bronze WH-P Wh te

12 Kim I ghting
Option Ordering lnformation
Reference symbo for f xture a ming range when mounted on the option as
shown Th s range s in the vert cal p ane and does not necessar y apply to
FiXtUfeS With Standafd SWiVel. Seeproductstructureps 4 a cond t ons. See page 1 I for full aiming range without mounting opt ons.

Barn Doors (BD) Extruded * Cat. No. Color


aluminum doors with anti- BD/BL-P Black.
ref lection baff es. Each door is BD/DB-P Dark Bronze
hinged to a cast aluminum BD/LG-P Light Gray. \
frame, and locks by set screws. BDAI/H-P White
Doors are individually rernov-
able. Barn Door assembly
mounts to predrilled door frame
holes. Note: Not recommended
lor g'oi,nd mounted fixtures ,n * These options may be
vandal prone areas. used on fixtures with
Heavy Duty Swivels.

Fixed Hood (FH) Formed %o' * Cat. No.


Color
thick aluminum. Mounts to FH/BL-P Black
predrilled door frame holes, and FH/DB-P Dark Bronze
may be used with polycarbon- FH/LG-P Light Gray
ate lens shield option. Can be FHA/VH-P White
---=-f.-
mounted along the top or bot-
tom of the fixture to shield the
lamp and ens from view.
)-r I 73A"

]
Note: Hood may be
applied as shown for
downward aiming oniy
Polycarbonate Lens Shield * Cat. No. AFL-LS
(AFL-LS) 131e" dear convex U.V
stabilized vacuum formed poly-
carbonate with gasket. Mounts Fr..---^.
I J"/4
I
.
over lens to predrilled door frame
and may be used with Barn Door
F
t
7
s/e"
or Fixed Hood option. For use
only when vandalism is antici- ----=_<1-
pated, whereas useful life is lim-
ited by U.V discoloration from
sunlight or metal halide lamps.

Architectural J-Box (JB1 )


Cylindrical body and matching t:' Cat, No.
JB1/BL.P
Color
Black,
cover in die cast aluminum.
One piece molded silicone
cover gasket. Interna ground -1*
lf %, N,PS.M.
Fixture Mount
JB1/DB-P
JB1/LG-P
Dark Bronze.
Light Gray
JB1/VI/H-P White
screw provided. Captive coun- 43/q'
tersunk cover screws. 72"
N PS N/ fixture mount with in-
ternal set screw lock. Two 1/2"
-L
N PS N/ for conduit entry. For
above grade installation only.
Two 7z'N.PS.M. H
Stanchion Mount for Single %, N.PS,M.
Cat. No, Color
Fixture (SM18) 3' O.D x 188' Fixture l\,4ount SM18i BL-P Black
wall cast aluminum wilh 1/2" SM18/DB-P Dark Bronze.
N PS N/ fixture mount and hand- SM18/LG-P Light Gray
hole with flush cover. lnternaL set SM18/WH-P White.
screw fixture Lock accessible
through handhole. lnternal Note: To assure a rigid installation and
grourd lJg supplisl product longevity, stanchion must be set
w th in-
stalled lead. in concrete by others.

d
,* By Others

Klm Lighting 13
Option Ordering Information
Reference symbo Jor f xture a ming range when mounted on ihe opt on as
shown. Th s range s in the vert ca p ane and does not necessar ly apply to
Fixtures with Standard SWiVel. See Product Structure pq.4 al condtofs. See page ii forfu aiming rangewthout rnountng options.

Wallor Ceiling Mount (WM) Cat No Coior


Electro zinc steel mounting plate WM/BL-P Black.
adapts to standard 4'square or WMiDB-P Dark Bronze.
octagonal J-boxes. Fixture mounts WM/LG-P Light Gray,
to cast aluminum upper cover WMAA'H-P White
which allaches Lo .noJnting
(T\-
q A
v
plate. Lower cover half provides
splice access. Dielectric sealing -Jf\ -v.,J

r-)
compound provided for wall in-
terface.
Wall
t
Box by
Others

Wall Mount (WM1): Extruded


aluminum arm with a removable
Cat. No.
WM1/BL-P Black
Color -z,
end cap for wiring access. Arm
is welded to a cast aluminum
plate with Iwo 1/2" dia. mounting
holes. Optional Wall Embedment
Bracket (WEB)with %'bolt re-
1/z'

N,PS.N/,

\
WM1/DB-P Dark Bronze
WM1/LG-P Light Gray,
WMI/$/H-P White
Component E.PA.: 0.3
4
ceptacles available for casting Optional Wal Embedment Bracket:
n concrete walls. For mounting Cat, No WEB

h
-r.:l;j
one fixture oniy.
_\iilr
u,/\
Surface Mount (J-27N) Cast Cat. No. Color
rron hot dipped galvanized with J-27N/BL-P Black
mounting ears for wood screw J-27N/DB-P Dark Bronze.
Frxture Mount
attachment to tree or wood J-27N/LG-P Light Gray
structure. 5.5 cubic inch splice J-27NM/H-P White
area with gasketed cover. 1/2"
N PS M. fixture mount and 1/z' Note: Surface Mount can be connected
N PS N/. conduit or cord seal to conduit or outdoor cord with a water-
proof cord seal (by others).
entry. Black, Dark Bronze, Light
Gray, White powder coat only.
Conduit or cord seal by others. 7:" N.PS.M. conduit This aiming range
or cord seal entry. Eq applies when
fixture is inverted
Post Top Mount (PT) One Qn ina
Cat, No, Color
piece cast aluminum for mount- PT/BL-P Black,
ing on pole or other mounting
option with 2'pipe-size tenon
(2V;' O D. x 3%' minimum
Access -----r
\
-T
PT/DB-P
PT/LG-P
PTAATH-P White
Dark
Ligrl
Bronze.
Gray
\.\
a\
a)
Length) Fixture attaches with '^j:H?
-----';>Q-" -g Component E.PA.: 0.07 flYr"
I
concealed internal studs and 4%' SPT
nuts, and mounting is with %-20 M3E
allen set screws. Top cap pro- I
ll wM2

wh
vides splice access, and Option wlth ( t- ,) or Kim pole
mounting allows 360' horizontal 2'Ptpe- I This aiming range (see p 15)
adjustment, Size Tenon l
applies when
---->l fixture is inverted

Twin Post Top Mount (PT2) Splice Cat. No. Color


One piece cast aluminum for Access PT2/BL-P Black
mounting on pole or other Fixture PTZDB-P Dark Bronze.
mou-ring option with 2 pipe- Mount PTALG-P Light Gray,
size tenon (23/e" O.D . x 31/z' 2 @ 180" PT2MH-P White
minrmum length) Fixtures at- --_---.,>
tach with concealed internal Component E.PA.: 0.1
studs and nuts, and mounting is
wilh 1/+-20 allen set screws. Top
cap provides splice access, Option with
and mounting ailows 360'hori-
zontal adjustment.
2'Pipe-Size
Tenon
OX
"ig h, rhis ainins ranse
r'-L7r applies when
' Iixture is nverted,
14 Kim L ghting
Option Orclering Information
,7{ R"f"r"n"" .ymbo for fi^ture a ming range when mounted on the opt on as
fi| shown Th s range s n the venca p ane and does not necessar y apply to
Fixtures with Standard SWiVel. See Product Structure pg 4 ) I al condtons.Seepage 11 forfulaiming rangewthoutmountngopions.

Twin Mount for Up Lighting Cat. No. Color


(TM2) Extruded alumlnum arm TM2iBL-P Black.
wrth two %'N.PS.M. fixture TM2lDB.P Dark Bronze
rnounts. Internal set screw TM2/LG-P Llght Gray
fixture ocks. Removable end TM2AA/H-P White
caps for wiring access. Cast
alumlnum tenon rnount for pole
Componenl EPA: 0.6
or slanchion wiLh 2 pipe-size
tenon (2 s" O.D. x 3' 'nin.
length) 360" fixture onentatron. Option with SM2
l

2'Pipe-Size SMT
Tenon -----+' or Kim po e
(see below)

Twin Mount Tenon (M2B) * Cat. No. Color


Recommended for down-lighting (2) 2" Ptpe-Size Tenons for PT M2BiBL-P Black.
and up-lighting, Extruded a u- M2B/DB-P Dark Bronze
minum arm with two 2'pipe- M2B/LG-P Light Gray
size tenons (23/a' O D, 2" I D ) for M2BA\/H-P White
use with PT to achreve a 210'
vertrca and 360' horizontal Component E.PA.: 0.6
adjustable aiming range. Can be
PT
mounted on a stanchion SM2 or ,/
pole with 2' pipe Ienon (23k" SM2
O.D.x31/2" min. length). Remo- This aiming range SMT
vable end caps for wiring access. applies when or Kim pole
fixture is inverted. (see below)

Side Pole Mount (SPM) Cat. No. Color


Recommended for up-lighting or SPMiBL-P Black,
dowr- ight ng app icarions. 7z'N PS.M. Dark Bronze
SPM/DB-P
Extruded aluminum arm wilh 1/z' Fixture Mount
SPMiLG-P Light Gray
N PS N/ fixture mount. Adjustable SPMAA/H-P White,
aiming range 120' vertical and
360' horizontal. Internal set Component E.PA.: 0.3
screw fixture lock. Removable
end cap for wiring access. For
use wrth other Kim Slte/Road- '-l
/d''^
tffi
way Lighting Luminaires as an
additiona mid-pole floodlight.

Side Pole Tenon (SPT) * Cat. No.Color


Recommended for up-lighting 2'Pipe-Size SPTiBL-P Black.
and for down- ighting applica- Tenon for PT SPT/DB-P Dark Bronze
tions. Extruded aluminum arm (2%',OD,2',tD) SPT/LG-P Light Gray
with one 2" pipe-slze Ienon (23/a" SPTA/VH-P White
O D ,2' I D ) for use with PT to
achieve a 210' vertica and 360' Component E.PA.: 0.3
^o'izontal adj-stable aiming
R.!
q
range. For use with other Kim
Site/Roadway Lighti ng Luminaires rat l
/\-Ll
as an additional mid-pole floodlight. This ainirg rarge
applies when
fixture is lnverted.

Pole Mounting:
For pole mounting AFL fixtures,
see the Kim Poles catalog in the
Site/Roadway section of the
Kim binder.

* These options may be


used on fixtures with
Heavy Duty Swivels

Kim Lighting 15
Option Ordering Information
Beference symbo for f xture a ming range when mountecl on the opt on as

Fixtufes with Heavy DUty Swivel. f'--1- shown Th s range page


s in the vertca p ane and does not necessar ly apply to
seeproducrstructureps 5 ,, , -/ a cond t ons See I I for fu a rning range wlthout mount ng options.

Heavy Duty Swivel (HDS) * Cat. No Color


Recommended for vanda HDS Furnished to
resistant requirements. Heavy match selected
cast aluminum with locking fixture color.
teeth, aiming range of 200' 1/z'
vertica in 5'increments and
7 Note: Heavy Duty Swivel (HDS) must
360" horizonta rotation, The be included in the fixture order number
sw vel mounts directly to a 2"
I
See page 12lor rnore information.
pipe-size tenon, with heavy )/ Factory assembled to fixture.
duly s/s'stainless steel set point \-,-r
screws provided to firmly ock t
ffiz
>"
2r/r' t7/"'
the fixture in place. tFrE
\r!n

Stanchion Mount Tenon (SM2) a Cat. No. Color


4' O.D. cast a um num stanchion SM2/BL-P Black.
with 2" pipe-size aluminum
lenon (23/a" O D, 13/e' I D ) for
mounting a single fixture or
multiple top-mounts. Cautron:
Multiple iop-mounts must not
be used in locations where
people can c mb on fixtures
and mounting arms.

W
Surface Mount Tenon (SMT) * Cat. No. Color
2'pipe-size (23/B' O.D ,2' I D ) 2'Pipe-Srze Tenon SMT/BL-P Black
alumrnum tenon welded to a (z%',OD ,2',tD)
cast aluminum plate. Plate has
four 1/z"dia. mounting ho es,
and tenon has one %" N.PT. for
(4)1/z' dta
holes on
S" circle
-4 51/z

side conduit entry. For mounting


one fixture only, )

/r'N.PT. R/ By
Conduit Entry tt#
,*
others.

Twin Mount Tenon (M2B) (2) 2" Pipe-Size Tenons Cat. No. Color
Recommended for down-light- tzv" o.D.,2'tDLl M2B/BL-P Black.
ing and up-lighting Extruded \ M2B/DB-P Dark Bronze
aluminum arm with two 2'pipe- \ t*'/20 ; M2B/LG-P Light Gray
size tenons (23/a' O.D., 2' l.D.) to \ | --''----' M2BMH-P White
achieve a 200'vertical and 360'
horizonlal adjusLable aining Component E.PA,: 0.6
range. Can be mounted on a
stanchion SM2 or pole with a
2'pipe-size tenon (2%" O.D. x
31/2" min. length) Removable
end caps for wiring access.
W or Kim Pole
(see p 15)

Triple Mount Tenon (M3E) (3) 2'Pipe-Size Tenons Cat. No. Color
Recommended for down-lighting M3E/BL-P Black.
and up-lighting. Extruded alumr- M3E/DB-P Dark Bronze.
n-- arm with three 2 pipe-s ze M3E/LG-P Light Gray
tenons (2Vd' O D., 2' l.D.) to M3EMH-P White.
achleve a 200" vertical and 360'
horizonral ad.usraole aiming Component E.PA.: 1.0
range. Can be mounted on a
stanchion SM2 or pole with 2"
pipe-size lenon (23/e'O D x31/2" SM2
mln. length). Removable end
caps for wiring access.
Pipe-Size -:-sMT
or Kim Pole
Tenon (see p 15)

16 Kim Light ng
Option Ordering lnformation
Reference symbol for flrture aimrng range when mounted on the optlon as
-^l
lrll shown. This range ls in the vertical plane and does not necessarily apply to
Fixtufes with Heavy DUty Swivel. See producr structure ps 5 j\*f,7 a I conditions. See page 1 1 for full dm ng range without mounting options.

Wall Mount (WM2) 2' pipe-size Cat. No. Color


aluminum Ienon (23/a' O.D.,2" 2'Pipe-Size
Tenon d
WM2/BL-P Black. (=:\
l.D.) welded to an extruded alu- WM2/DB-P Dark Bronze.

>J
(23/a' O.D..Z' LD.\ | 4'
WMZLG-P Light Gray.
minum arm with a removable
end cap for wiring access. Arm WM2MH-P White.
tr'
T
q)
is welded Lo a cast aluminum
plate with Iwo 1/z'dia, mounting Component E.PA.: 0.3
holes. Optional Wall Embed-
ment Bracket (WEB) wilh 3/e'
bolt receptacles available for
casting in concrete walls. For
mounting one fixture only.
t7'
Optional Wall Embedment
Bracket:
Cat. No. WEB
"@
Side Pole Tenon (SPT) Cat. No. Color
Recommended for up-lighting 2'Pipe-Size SPT/BL-P Black.
and for down-lighting applica- Tenon SPT/DB-P Dark Bronze.
tions. Extruded aluminum arm (23/8', O.D., 2', I D.) SPT/LG-P Light Gray.
with one 2' pipe size tenon I SPTAATH-P White.
(23/e' O.D., 2' l.D.) to achieve a V
200'vertical and 360" horizontal Component E.PA.: 0.3
adjustable aiming range. For
use with other Kim Street or
Area Lighting Luminaires as an
additional mid-pole floodlight. Rt
t#
>-

wr
rt It lt
rxlx@g
x
^*8
AEBa

Kim Lighting 17
Photometrics and Fb<ture Spacing
3-Step System
Floodl Parking Lot Lighting
Determine llluminance level Sunounding Light Level
required. Surface Material Examp es Dark
Maintained Footcandles
Charts at right show l.E.S,
Light marble, white plaster, white or
recommended llluminance in
Average Maintained Footcandles. cream terra cotta.
These tinted values correspond Concrete, tinted stucco, bu{f lace brick
to the tinted values on each iso- Common tan brick, sandstone, medium
footcandle diagram on the gray limestone.
I
following photometric pages.
Common red brick, stained wood,
dark gray brick

For facade, wall or sign light-


Determine uniformity ol ing, optimum, visual uniformity
illumination required. is achieved when the maxi-
mumlo-minimum illumination is
Note: All areas of uniformity are no greater than 3:1.
based on a lighting system, not
individual f ixtures, Therefore Use solid blue area of
areas of uniformity are calcu- I isofootcandle diagram
I
lated assuming contributions to determine fixture
f rom adjacent f ixtures. spacings.

For facade, wall or sign lighting


where a slight noticeable drop
in illumination between fixtures is
acceptable, use 6:l uniformity.

Use shaded blue


area of isofootcandle
diagram to determine
fixture spacings.

For parking lot or area lighting,


a 12:1 maximum{o-minimum
uniformity will provide excellent
results. +\
-v-t
wa'
Use area within
dashed blue line on
isofootcandle diagram
to determine fixture
spacings. Parking Area

Dimension X is obtained Dimension Y (fixture spaclng) is


Determine X and Y fixture
directly from the isofootcandle simply a multiple of X obtained
spacings.
diagram. Listed X dimensions by figuring the longitudinal dis-
represent the optimum range tance to the next fixture. The
for that lamp and wattage. next fixture is located where its
iight pattern intersects the pre-
vious fixture as illustrated
above.

18 Kim Lighting
AFL I Horizontal Flood AFL I Horizontal Flood

70 Watt High Pressure Sodium ED17 ctear med. base 100 Watt High Pressure Sodium ED17 ctear med. base
6300 initial lumens. LT.L. Test No. 32061 9500 initial lumens. l.T.L. Test No. 32062

See page 18 for I E.S recom- l.E.S.Type:7 x 7 See page 18 for l.E,S. recom- l.E.S.Type:7 x 7
mended illuminance for flood- Field Angle: 165.9"H x 140.4'V mended illuminance for flood- Field Angle: 164.5"H x 139.3"V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting. (10% of max.)

I Note: All areas of uniformlty are based on a lighiing system, not Note: All areas of uniformity are based on a lightlng system, nol
l individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures,
I

Aiming
^

l<-X ------------->l

-
151 (10% oJ lvax. - 228 (10% of Max.)

10' 20' 30'40'50'60'70 80' 30'40'50'60'70' 80'

X X
o o
o o
o o
=l -
.E .g
o o
i
o
o
c
d
.9
;1,;1,il-i--,W o
C
d
.9
o
\ d
o
d
^- d
o
6
fit al Footcand es J nltia Footcafdles J
at Distance X at D stance X

Longitudinal Distance ln Multiples Longitudinal Distance in Multiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y. See page 18)

- -\ 3:1 maximum-to-minimum uniformity 6:1 maximum-to minimum uniformity of 12:1 maximum{o minimum uniformity
I of illumination. Use for optimum visual illumination. Use where a slightly notice- of illumination. Use for area lighting
I uniformity on facades, walls or signs. able drop in illumination is acceptable. where fixture is wall or pole mounted.

Kim Lighting 19
AFL I Horizontal Flood AFL I Horizontat Ftood

150 Watt High Pressure Sodium ED17 ctear med. base 70 Watt Metal Halide ED17 ctear med.base
16,000 initial lumens. I.T.L. Test No. 32063 5000 initial vefiical lumens. l.T.L. Test No. 36448

See page 1B for LE.S. recom- l.E.S.Type: 7 x 7 See page 1B for l.E.S. recom- LE.S.Type: 7 x 7
mended illuminance for flood- Field Angle:163.7"H x 141.8"V mended illuminance for flood- Field Angle: 1 53.5"H x 131 .4"V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting. (10% of max.)

Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures.

80'
Typical Half
70' Aiming
60'
^
50'
40 40'
30 30"
20 20'
10 10'
0' 0' !-X ---+l
10 10'
20'
30'
40"

50'
X ^'
Aiming ) -+-T I
X
,A.

1 95 (10% of Max.) Aiming


I _+-r*ts-
367 (10% of Max.)

10' 20' 30'40'50'60'70' 80' 10' 20' 30'40'50'60'.70' 80'

.13

.zc
>< X
.5 o o
o o
1.3 a
E o
l
=
.g .E
o o
O
c o
6 c
d
.9 .9
o o
_v_ E v_
o o
lnit al Footcand es 6 jd
J ln tial Footcandles
at Distanc-6 X at D stance X

Longitudinal Distance in Multiples Longitudinal Distance in Multiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y. See page 18)

- -., 3:1 maximum-to-minimum uniformity 6:1 maximum{o minimum uniformity of 12:1 maximumlo minimum uniformity
I of illumination. Use for optimum visual illuminatjon. Use where a slightly notice- of illumination. Use for area lighting
I uniformity on facades, walls or signs. able drop in illumination is acceptable. where fixture is wall or pole mounted.

20 Kim Lighting
AFL I Horizontal Flood AFL I Horizontal Flood

100 Watt Metal Halide ED17 clear med. base 150 Watt Metal Halide ED17 clear med. base
7200 lnitial verlical lumens. l.T.L. Test No. 32710 11,500 initial vertical lumens. l.T.L. Test No. 36244

See page 18 for I E.S recom- LE.S.Type: 7 x 7 See page 18 for l.E.S recom- l.E.S.Type: 7 x 7
mended illuminance for flood- Field Angle; 155.6'H x 137.0'V mended illuminance for flood- Field Angle: 164.8"H x 137.9'V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting (10% of max.)

Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
indlvidual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures.

l<-x-------N l<--X------+l

)-J-t I

176 (10% of Max tggo (toy. of Max.)

10' 20" 30' 40' 50' 60' 70"

.08 .20
.20 .35
.90 1.2 .b 2.3
1.6 2.8
.20 .26 .35 .50 .39 .69
1.2
eo
1.6
.51
2.2
.69
3.1
1.0
X 2.1 2xx
o .78 1.4 o
1.4 2.4 4.7
.78 1.0 'l.4 2.0 o 3.0 5.3 o
o 2.0
1x
2.0 3.5
= eo =o
=
,c .=
o
o 0Xo o
C c(6
cd 16' 1 12' 10' l 8'
.9 .2

A-
o
6 v_ 1xGo
o o
lnitla Footcand es (!
cd
J lnrtial Footcandles J
at Distance X at Dlstance X 2X

Average Maintained Average Maintained


Footcandles within area Footcandles within area
of designated uniformity. of designated uniformity.
Assumes contribution Assumes contribution
from adjacent fixtures. from adjacent fixtures.
See note above. Longitudinal Distance in Multiples See note above. Longitudinal Distance in Multiples
of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y, See page 18)

3: 1 maximum-to-minimum uniformity 6:1 maximum{o minimum uniformity of \ 12:1 maximumto minimum uniformity
of illumination. Use for optimum visual illumination. Use where a sllghtly notice- I of illumination. Use for area lighting
uniformity on facades, walls or slgns. able drop in lllumination is acceptable. I where fiture is wall or pole mounted.

Kim Lighting 21
AFL I Horizontal Flood AFL I Horizontal Flood

175 Watt Metal Halide ED17 clear med. base 500 Watt Quartz T-4 mini-can
14,000 initial vertical lumens. l.T.L. Test No. 32709 10,450 initial lumens. l.T.L. Test No. 39577

See page 1B for LE.S. recom- l.E.S.Type:7 x 7 See page 18 for LE.S. recom- l.E.S.Type: 7 x 7
mended illuminance for flood- Field Angle: 155.6"H x 137.0'V mended illuminance for flood- Field Angle:160.1"H x 150.5"V
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting. (10% of max.)

Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated indivldual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent f ixtures, assuming contributions from adjacent fixtures.

Aiming Aiming
^ ^.

l<-X-----+l <-X-,- +l

X Aiming
- 343 (10% of Max.) ' 231 (10% o{ Max.)

1 0' 20' 30' 40- 50' 60' 70' 80' 10 20' 30'40'50'60'70' 80.

X X
o o
o o
o o
=J 5

.c .=
o o
o
c c
20'116 112'110'18' 6 16 114'112'110 8 6
.9 _a
o o
d G
o o
nt a Footcandles jd ln tia Footcand es 6
I
at D stance X al D slance X

Longitudinal Drstance in Multiples Longitudinal Distance in Multiples


of X (Use to determine f ixture of X (Use to determine fixture
spac ng Y. See page 1 B) spacing Y. See page 1B)

\ 3:1 maximum-to-minimum uniformity 6:1 maximum-to minimum uniformity of 12:1 maximumlo minimum uniformity
I of illumination. Use for optimum visual illumination. Use where a slightly notice- oi illumination. Use for area lighting
I uniformity on facades, walls or signs. able drop in illumination is acceptable. where fixture is wall or pole mounted.

Kim Lightlng
AiFL 2 Verlical Flood AiFL 2 Vertical Flood

70 Watt High Pressure Sodium ED17 ctear med. 100 Watt High Pressure Sodium ED17 ctear med
base 6300 initial lumens. l.T.L. Test No. 32065 base 9500 initial lumens. l.T.L. Test No. 32066

See page 18 for l.E.S. recorn- LE.S. Type: *6 x 6 See page 18 for l.E.S. recom- l.E.S.Type: *6 x 6
mended illuminance for flood- Field Angle: 124.3"H x 106.9'V mended illuminance for flood- Field Angle:123.3'H x 105.7"V
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting (10% of max.)
*Standard beam descriptions Beam Angle:84.0"H x 80.0"V *Standard beam descriptions Beam Angle: 82.0'H x 76.0"V
do not adequately define the (50% of max.) do not adequately define the (50% of max.)
unique AFL2 optical system. unique AFL2 optical system,
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures, Therefore, areas of uniformity are calculated
assuming contributions from adlacent fixtures. assuming contributions from adjacent fixtures.

351 (10% of [/ax.


t\+-1 I

l<_N________>l l<- N-------------->l

10'
225 (10'/. of Max.)

20 30'40'50'60 70" 80
# 10 20' 30'40'50'60'70' 80'
-#
Ground Ground
.08
.20

.39

.78
X X
o 2.0 o
o o
o 3.9 o
E
=f -
L I .g .=
o
I I I
12 110 | I I 6
ITTTTTTM
U++rJ
It
o
o
c
6
.9 16' 14' I 12 I 10' 8
o
c
.9
o o
6 v_ G
o o
d J
nlt a Footcand es J nit a Footcand es
at D stanc-. X at D stanc-. X

Longitudinal Distance in Multiples LongitudinaL Dlstance in Multiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y See page 1B) spacing Y. See page 18)

- -\ 3:1 maximum-to-minimum uniformity 6:1 maximum{o minimum uniformity of 1 2:l maximumlo minirnum uniformity

I of illumination. Use for optimum visual illumination. Use where a slightly notice- of illumination. Use for area lighting
I uniformity on facades, walls or signs. able drop in illumination is acceptable. where fixture is wall or poie mounted.

Kim Llght ng 23
AFL 2 Vertical Flood AiFL 2 Vertical Flood

150 Watt High Pressure Sodium ED17 ctear med base 70 Watt Metal Halide ED17 clear med. base
16,000 initial lumens. l.T.L. Test No. 32067 5280 initial horiz. lumens. l.T.L. Test No. 33037

See page 1B for LE.S. recom- LE.S. Type: *6 x 6 See page 18 for LE.S. recom- LE.S. Type: *7 x 6
mended illuminance for flood- Field Angle: 124.3'H x'106.5'V mended illuminance for flood- Field Angle: 133.7"H x 112.4'Y
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting (10% of max.)
*Standard beam descriptlons Beam Angle:84.0'H x 75.0'V *Standard beam descriptions Beam Angle:90.0'H x 80.0'V
do not adequately define the (50% of max.) do not adequately define the (50% of max.)
unique AFL2 optical system. unique AFL2 optical system.
Note: Al areas of uniformity are based on a lighting systern, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assumrng contrlbutions from adjacent fixtures. assuming contributions from adjacent fixtures,

50'
590 (10% of Max.) 40 184 (10% of Max.)

30'
20
10'
l<-X__,,, > <- 1-------------->l

g
1 0' 20' 30' 40' 50' 60' 70
Ground Ground
.20

.39

.78

2.0
X X
3.9 o o
o o
7.8 o o
E =f
f

.E .=
o o
o O
c C
6 d
.9 1412'110'1816 .q
a o
d _v d
o o
6 d
n tla Footcandles J ln tia Footcandles J
at D stance X at D stance X

Longitudinal Distance in Multiples Longitudinal Distance in Mu tiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y See page 1B)

- -\ 3:l maximum-to-minimum uniformity 6:l maximumlo minimum uniformity of 12:1 maximum{o minimum uniformity
I of illumination. Use for optimum visual illumination. Use where a siightly notice- of illumination. Use for area lighting
I uniformity on facades, walls or siqns. able droo in illumination is acceptable. where fixture is wall or pole mounted.

24 Kim Lighting
AFL 2 Vertical Flood AiFL 2 Vertical Flood

100 Watt Metal Halide ED17 ctear med base 150 Watt Metal Halide ED17 ctear med. base
6912 initial horiz. lumens. l.T.L. Test No. 33036 11,040 initial horiz. lumens. l.T.L. Test No. 33035

See page 18 for LE.S. recom- l.E.S. Type: *6 x 6 See page 1B for LE.S. recom- l.E.S. Type: *7 x 6
mended illuminance for flood- Field Angle:133.6"H x 112.5"V mended illuminance for flood- Field Angle: 133.6'H x 112.4"Y
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting (10% of max.)
*Standard beam descriptions Beam Angle: 90.0"H x 81 .0'V *Standard beam descriptions Beam Angle: 90.0'H x 81 .0'V
do not adequately define the (50% of max.) do not adequately define the (50% of max.)
unique AFL2 opticai system. unique AFL2 optical system.
Note: Al areas of unrformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated indlvidual fixtures. Therefore, areas of uniformity are ca culated
assuming contributions from adjacent fixtures. assuming contr butjons from adjacent fixtures.

lsocandela Diagram

0 (10% of Max.) 400 (10% of Max.)

l<-X,,-*-- ,> l<_x_______f

{f,
10' 20' 30 40'50'60'70' 80' 10' 20' 30'40'50 60'70' 80'
Ground Ground

x X
o o
o o
o o
=f =f
.E .=
o o
o o
c C
16 114 112' 10 I 8'
6
.9 16 114 112' 10'l 8',
6
.9
o o
d X d
o o
G N
nit a Footcand es J fit a Footcand es I
at Distafce X at Distance X

LongltudinaL Distance in Multiples Longitudina Dlstance in l\4ultlples


of X (Use to determlne fixture of X (Use to determ ne fixture
spac ng Y. See page 1B) spac ng Y See page 1B)

- -\ 3:1 maximum-to-minimum uniformity 6:1 maxrmum{o minimum uniformity of 12:l maxmumlo minimum uniformrty
I of illumlnation Use for optimum visual illumination. Use where a s ightly notice- of illumination Use for area lighting
I uniformity on facades, walls or signs. able drop in illumination is acceptable. where fixlure is wall or pole mounted.

Kim Liqhtinq 25
AFL 2 ve,ticat Ftood AFL 2 vertical Flood

175 Watt Metal Halide ED17 ctear med. base 500 Watt Quartz T4 mini-can
13,440 initial horiz. lumens. l.T.L. Test No.33034 10,450 initial lumens. l.T.L. Test No. 39578

See page l8 for l,E.S. recom- l.E.S. Type: *7 x 6 See page 18 for l.E,S. recom- LE.S.Type: *7 x 6
mended illuminance for flood- Field Angle: 133.6"H x 112.4"Y mended illuminance for flood- Field Angle:133.7'H x 109.8'V
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting. (10% of max.)
*Standard beam descriptions Beam Angle: 90.0'H x 81 .0'V *Standard beam descriptions Beam Angle:88.7'H x 76.3"V
do not adequately define the (50% of max.) do not adequately define the (50olo of max.)
unique AFL2 optical system. unique AFL2 optica system.
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributlons from adjacent fixtures. assuming contributions from adjacent fixtures.

64'
56
343 (10?" ol Max.) 48'
40'
(10% of Max.)
-,467 32'
24'
16'
8'
< X ------>l 0' k__x ___>l

16
llt
1877-50"k

./$t
*.{t
g
10' 20 30'40'50'60'70' 80' 16' 24' 32' 40" 48' s6', 64'
Ground Ground

X X
o o
o o
o o
!
= =
.= .=
o
o o
O
c c
20 116 112' 10 8', 16 14 12' I 10' I I' d
.9 .9
o o
E v_ 6
o o
tia Footcandles 6 a 6
n J lnit F-ootcand es J
at D stance X at Distance X

Longitudinal Distance in Multiples rongitudinal Drstance in Multiples


of X (Use to determine frxture of X (Use to determine fixture
spac ng Y. See page 1 B) spacing Y. See page 18)

\ 3:l maximum-to-minimum uniformity 6:1 maximum-to minimum uniformity of 12:1 maxrmum{o minimum uniformity
I of illumination. Use for optimum visual illumination, Use where a slightly notice- of illumination. Use for area lighting
I uniformity on facades, walls or signs. able drop in illumination is acceptable. where fixture is wall or pole mounted.

26 Kim Lighting
AFL 3 Horizontal Spot AFL 3 Horizontal Spot

70 Watt High Pressure Sodium ED17 clear med. 100 Watt High Pressure Sodium ED17 clear med. base
base 6300 initial lumens. LT.L. Test No. 32072 9500 initial lumens. l.T.L. Test No. 32073

See page 18 for LE.S recom- l.E.S.Type:6 x 5 See page 18 for l.E.S. recom- l.E.S.Type:6 x 5
mended illuminance for flood- Field Angle: 108.3'H x 96.8"V mended illuminance for flood- Field Angle:110.9'H x 95.6"V
lighting and parking lot lighting. (10% of max.) lighting and parklng lot lighting (10% of max.)
Beam Angle:80.0'H x 18.0'V Beam Angle:80.0"H x 18.0"V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of unlformlty are calculated
assuming contributions from adjacent flxtures, assuming contributions from adjacent fixtures.

tl I

lsocandela I )iagram b4
TvDical Hall l
56

48 A
- 490 (10% of Max.) 797 (1Ok ot Ma Aiming
40
I
, JZ
24
16
GroundT/z'
8'
$\ t
0'
I
F 90( 8'

N
\N\
1nr 16

24

X\ i00(
znn(
A
Aiming
ll L
10' 20" 30'40" 50'60" 70" 80' v2
ti
0"40'50'6 JI
L
0'

X X
o o
o o
o o
= =
,c .g
o o
o c
c cd
cd
.2 .9
o o
v_ E E
o o
(E
lnit al Footcand es I ln tial Footcandles J
at Distance X at D stance X

AveraEe Maintained .I.vcra ge iutla ! -


ri'ta i rred
Footcandles within area r.ootcanciles uvlfhll.r area
of designated unifornrity. o1i clesir gna'ied ur.r rforrrr i',iy.
Assumes contribution l\$s!"i rfl es cor'rtr'i bution
from adjacent fixtures. f r"olrn adlaeent rixft..i res.
See note above. Longitudinal Distance in Multiples See note alllove. Longitudinal Distance in Multiples
of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 1 8) spacing Y, See page 18)

3:1 maximum-to-minimum uniformity of lllumination. Use for 3:1 maximum-to-minimum uniformity of illumination. Use {or
optimum visual uniformity on facades, walls or signs. optimum visual uniformity on facades, walls or signs.

Kim Lighting
AFL 3 Horizontal Spot AFL 3 Horizontal Spot

150 Watt High Pressure Sodium ED17 ctear med. base 70 Watt Metal Halide ED17 clear med. base
16,000 initial lumens. I.T.L. Test No. 32074 5280 initial lumens. l.T.L. Test No. 33041

See page 18 for LE.S. recom- l.E.S.Type:6 x 5 See page 1B for LE.S, recom- l.E.S.Type:6 x 5
mended illuminance for flood- Field Angle:109.9"H x97.2.Y mended illuminance for flood- Field Angle: 120.7'H x 97.1"V
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting (10% of max.)
Beam Angle:80.0"H x 18.0"V Beam Angle:84.0"H x 17.0"V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures, Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures,

A
- tzss 1tot" of Max.) Aiming 493 (10% o{ Max.)

X
1 200
l
1 900
I

2700
I

3400
I

41 00
l

4600
Aiming

10' 20' 30'40'50'60'70' 80' 10 20'30 40 50'60 70 80

.40
.80

X X
o 2.0
o
o o
o .s
=- 4.0 -

_v
.c

o
o
O
c
6
.9.

6
ft-trW
30 zslzolts
v_
e.o .=

o
6
o
O
c
6
.9

o o
ln tia Footcandles jd lnit a Footcand es )6

at Dlstance X at Distance X

Longitudinal Distance in Multiples Longitudinal Distance in Muitipies


of X (Use to determine fixture of X (Use to determine frxture
spacing Y See page 1B) spacing Y See page 18)

\ \
1 3:1 maximum{o-minimum uniformity of illumination. Use for I 3:1 maximum-to-minimum uniformity of illumination. Use for
I optimum visual uniformity on facades, walls or signs. I optimum visual uniformity on facades, walls or signs.

Kim Lighting
AFL 3 Horizontal Spot AFL 3 Horizontal Spot

100 Watt Metal Halide ED17 clear med. base 150 Watt Metal Halide EDl7 clear med. base
6912 initial horiz. lumens. LT.L. Test No. 33040 11,040 initiallumens. LT.L. Test No.33039

See page 18 for l.E.S. recom- l.E.S.Type:6 x 5 See page 18 for l.E.S. recom- l.E.S.Type:6 x 5
mended illuminance for flood- Field Angle: 120.7'H x 97.1"V mended illuminance for flood- Field Angle: 120.7'H x 97.1'V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting. (10% of max.)
Beam Angle:84.0'H x 15.0'V Beam Angle:86.0'H x 18.0"V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated lndividual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures, assuming contributions from adjacent fixtures.

tttt ttl
--L )4 )+
r""i""ii"il Typical Hall
l6

Aiming
ttl --f t6
l8
Aiming
516 (10% of Ma 824 (10% of Max.)
tth )

I I
24

b I
to
3"
- l"
11 00 1 800 3'
I

1t r00 16' 2900 16


zi i00 24' ft I

24
I
J 00 JZ
g 32
J< t00 40" 6( 00 40
48" 7C 00 48
56'
Aiming
56

'10" 20' 30"40"50"60"70" 80"


tttl
l" 0' 30'40'50" 60'70" t'

.40
.80

2.0 x 1xx
o o
o o
11.0 o o
4.0
8.0 = =
.g .E
o
o
C
0xgc
(E (d
.a .9.
o o
w_ E
o o
6 d
nit al Footcand es J lnitlal Footcandles J
at Distance X at Distance X 1X

Average Maintained - Average Maintained


Footcandles within area Footcandles within area
of designated uniformity. of designated unifornrity.
Assumes contribution Assumes contribution
from adjacent fixtures. from adiacent fixtures"
See note above.
Longitudinal Distance in Multiples See note above"
Longitudinal Distance in Multiples
of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y, See page 18)

3:1 maximum{o-minimum uniformity of illumination. Use for 3:1 maximumto-minimum uniformity of illumination. Use for
optimum visual uniformity on facades, walls or signs. optlmum visual uniformity on facades, walls or signs.

Kim Lighting
AFL 3 Horizontal Spot AFL 3 Horizontal Spot

175 Watt Metal Halide ED17 ctear med. base 500 Watt Quartz T4 mini-can
13,440 initial horiz. lumens. l.T.L. Test No 33038 10,450 initial lumens. l.T.L. Test No. 39579

See page 18 for LE.S. recom- LE.S.Type:6 x 5 See page 1 B for L E.S. recom- l.E.S. Type: 6 x 5
mended illuminance for f lood- Field Angle: 12O7"H x 97.1 .V mended illuminance for flood- Field Angle: 125.4'H x 99.2'V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting (10% of max.)
Beam Angle:86.0'H x 18.0"V Beam Angle: 76.8'H x 24.8"Y
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures.

1003 (10% of Max.)


Aiming

Aiming

10' 20 30 40"50'60'70' 80
8' 16' 24'32 40'48 56 64'

.07
.15

X .37 X
o o
o .73
o
o .g
== 1.5 -
.= .=
o o
o
c c
6
.9 40' 35' I 30' I 25' .a
o o
E t
o o
a
6
J )d
Init Footcand es
at Distanc-. X
lnit al Footcand es
at Distance X
-

Longitudinal Dlstance in Multiples Longitudinal Dlstance in Multiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y See page 1B) spacing Y See page 18)

\g |l
3:1 maximum-to-minimum uniformity of illumination, Use for 1 3:1 maximum{o-minimum uniformity of illumination. Use for
I optimum visual uniformity on facades, walls or signs. I optimum visual uniformity on facades, walls cr signs.

30 K m Lighting
T
AiFL 4 oval Spot AFL 4 ovat Spot
i
I

70 Watt High Pressure Sodium ED17 clear med 100 Watt High Pressure Sodium ED17 ctear med. base
base 6400 initial lumens. l.T.L. Test No. 39866 9500 initial lumens. l.T.L. Test No. 39867

See page 18 for LE.S, recom- l.E.S. Type: 3 x 2 See page 18 for LE.S. recom- LE.S. Typer 4 x 3
mended illuminance for f lood- Field Angle: 44.3'H x 28.7"Y mended illuminance for flood- Field Angle:49.1'H x 30.9"V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting (10% of max.)
Beam Angle:22.6'H x 13.1"V Beam Angle:24.9"H x 14.1'V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated indlvidual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures.

lsocandela Diagram

A
Aiming Aiming

1 1,3'13-

Aiming

12'15'18'21 24 12 15' 18'21' 24

.25X x ><
o o
@
o o
o o
=f =f
.E .g
0Xo o
c
6
.9
o
;T;ET, q+P o
O
c
d
.9
o
d
o o
d 6
lnit a Footcand es J ln tia Footcandles J
at Distance X .25X at D stanoe X

Longitudinal Distance in Multiples Longitudinal Distance in Multiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y, See page 18)

\ \
I 3:1 maximum-to-minimum uniformity of illumination. Use for 1 3:1 maximumlo-minimum uniformlty of illumination. Use for
I optimum visual uniformity on facades, walls or signs. I optimum visual uniformity on facades, walls or signs.

Kim Lighting 31
A;FL 4 ovat Spot AFL 4 oval Spot

'150 Watt High Pressure Sodium ED17 ctear med. base 70 Watt Metal Halide ED17 clear med. base
16,000 initial lumens. l.T.L. Test No. 39868 5600 initial lumens. l.T.L. Test No. 39869

See page 1B for LE.S. recom- LE.S.Type:4 x 3 See page lB for LE.S. recom- l.E.S.Type:3 x 1
mended illuminance for f lood- Field Angle: 63.1'H x 46.0"V mended illuminance for flood- Field Angle:40.5"H x 13.9'V
lighting and parking lot lighting. (10% of max.) lighting and parking lot lighting. (10% of max.)
Beam Angle:31 .9'H x22.5"Y Beam Angle: 2O.7'H x 6.5'V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adlacent fixtures. assuming contributions from adjacent fixtures.

24'
21'
18'
Aiming Aiming
15'
12'
9'
6"

3'
0'
3'
b
o

12

15'

A 18
Aiming 21' Aiming

24

s' 10' 15"20'25" 30" 35' 40" 12'1s'14'21 24

.25X x .25X x
o o
o
tr e
l
=
C .=
OX; O
0xo
c c
6 6
.9 .9
o o
G G
o o
ln tia Footcand es
.25X
6
J nit a Footcand es )
d
at Dlstance X at Distanoe X .25X

Longitudinal Distance in Multiples Longitudina Distance in Multiples


of X (Use to determine fixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y. See page 1B)

\ \
1 3:1 maximum{o-minimum uniformity of illumination. Use for 1 3:1 maximumto-minimum uniformity of illumination. Use for
I optimum visual uniformity on facades, walls or signs. I optimum visual uniformity on facades, walls or signs.

32 Kim Liqhtinq
AFL 4 oval Spot AiFL 4 oval spot

100 Watt Metal Halide ED17 clear med. base 150 Watt Metal Halide ED17 clear med. base
8500 initial lumens. l.T.L. Test No. 39870 13,500 initial lumens. l.T.L. Test No. 39871

See page 18 for I E.S recom- l.E'S' Type: 4 x 2 See page 18 for l.E.S. recom- l.E.S.Type:3 x 2
mended illuminance for flood- Field Angle: 49.7'H x 19.0"V mended illuminance for flood- Field Angle: 43.5'H x 24.6"V
lighting and parking lot lighting. (10% of max') lighting and parking lot lighting (10% ol max.)
Beam Angle: 25.8"H x 8.0'V Beam Angle:21.3"H x 10.9'V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lighting system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas of uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures.

lsocandela Diagram

12'15'18'21' 24' 12'15" 18" 21' 24'

.88 t.5 2.0. .25X x .25X x


o o
2.2 5.0 @
o
14.0 23.2 31.8 o
o o
44 7.3 10.0 E ==
5
.c .=
0x3 E
0x8 c
6 (s
.9 .9
o o
d v- 6
o o
($ c6
lnit al Footcand es J lnit a Footcand es J
at Distance X .25X at Distanoe X .25X

Average Maintained - Average Maintained


Footcandles within area Footcandles within area
of designated uniformity. of designated uniformity.
Assumes contribution Assumes contribution
from adjacent fixtures. from adjacent fixtures.
See note above. Longitudinal Distance in Multiples See note above. Longitudinal Distance in Multiples
of X (Use to determine fixture of X (Use to determine fixture
spacing Y, See page 18) spacing Y. See page 18)

3:1 maximum{o-minimum uniformity of illumination. Use for 3:1 maximum-to-minimum uniformity of illumination, Use for
optimum visual uniformity on facades, walls or signs. optimum visual uniformity on facades, walls or signs.

Kim Lighting 33
AFL 4 ovat Spot AiFL 4 oval Spot

175 Watt Metal Halide ED17 clear med. base 500 Watt Quartz 14 dear med. base
15,000 initial lumens. l.T.L. Test No. 39872 10,450 initial lumens. l.T.L. Test No. 39964

See page 18 for l.E.S. recom- l.E.S.Type:3 x 2 See page 1B for LE.S. recom- l.E.S.Type:3 x 2
mended illuminance for flood- Field Angle:44.0'H x28.2"Y mended illuminance for flood- Field Angle: 42.7'H x 19.3'V
lighting and parking lot lighting (10% of max.) lighting and parking lot lighting (10% of max.)
Beam Angle: 21 .5'H x 11.9"V Beam Angle: 23.1'H x 9.5'V
(50% of max.) (50% of max.)
Note: All areas of uniformity are based on a lightlng system, not Note: All areas of uniformity are based on a lighting system, not
individual fixtures. Therefore, areas of uniformity are calculated individual fixtures. Therefore, areas oi uniformity are calculated
assuming contributions from adjacent fixtures. assuming contributions from adjacent fixtures.

Aiming Aiming

12"15'18'21 24' 9' 12 15 18'21' 24

.88

X 2.2 ><
o o
4.4
o 8.8 o
a o
= ==
.= .E
o o
O
c c
6 d
.9 .9
o o
Y- G v_ 6
o o
6 6
lnit al Footcandles J ln tlal Footcandles
at D stance X at D stance X

Longitudinal Distance in Multipies Longitudinal Distance in Multiples


of X (Use to determine f ixture of X (Use to determine fixture
spacing Y. See page 18) spacing Y. See page 1B)

\ \
I 3:1 maximumlo-minimum uniformity of illumination. Use for 1 3:1 maximumto-minimum uniformity of illumination. Use for
I optimum visual uniformrty on facades, walls or signs. I optimum visual uniformity on facades, walls or signs.
AFL 1-4 Beam Spread Ghart

AFLl 70W High Pressure Sodium 165.9'H x 140.4"Y 32061


Horizontal ED17 Clear Med. Base
Flood
100W High Pressure Sodium 164.5'H x 139.3"V 32462
ED17 Clear Med. Base
t Beam Angle: 150W High Pressure Sodium 163.7'H x 141 8'V 32063
ED]7 Clear Med. Base
Standard i.E.S
def nition of beam 70W Metal Halide 153,5'H x 131.4'V 36448
ang e does not ED.17 Clear Med. Base
apply to the
AFLl reflector. 1OOW Metal Halide 155.6'H x 137.0'V 327 10
ED17 Clear Med. Base
Please refer to 150W Metal Halide 164.8'H x 137.9"V 36244
the appropriate
ED17 Clear Med. Base
isocande a chart
for further 175W Metal Halide 155.6'H x 137.0'V 32709
information ED17 Clear Med. Base
5O0W Quartz 160.1'H x 150.5'V 39557
T4 Mini-Can
70W High Pressure Sodium t 124.3"H x 106.9'V 84.0'H x BO.O'V 32065
AFL2 ED.17 Clear Med. Base
Vertical *123.3'H x 105.7'V
100W High Pressure Sodium B2.O'H x 76.0'V 32066
Flood
ED17 Clear Med. Base
*Fietd Angte:
150W High Pressure Sodium tt124.3'H x 106.5'V 84.0'H x 75.0'V 32067
Standard beam ED]7 Clear Med. Base
descr pt ons do nol
adequate y deflne 70W Metal Halide *133.7'H x 112.4"Y 90.0'H x BO.O'V 33037
the un que AFL2 ED17 Clear Med. Base
optica system *133.6'H x 112.5'V 90.0'H x 81.0"V 33036
100W Metal Halide
(see p.9).
ED17 Clear Med. Base
The isofootcandle 150W N/etal Halide *133.6'H x 112.4"V 90.0'H x 81.0'V 33035
d agram represents EDl7 Clear Med, Base
the only true
performance 175W Metal Halide *133 6'H x 112.4"Y 90.0'H x 81.O'V 33034
p cture for the EDl7 Clear Med. Base
AFL2 aI
500W Quariz *133.7'H x 109.8'V BB.7'H x 76.3'V 39578
optimum tilt.
T4 Mini-Can
70W High Pressure Sodium 80.0'H x 18.0'V 32072
AFL3 EDl7 Clear Med. Base
Horizontal 10.9'H x 95.6"V 80.0'H x 18.0'V 32073
1OOW High Pressure Sodium 1
Spot
ED17 Clear Med. Base
150W High Pressure Sodium 109.9'H x97.2"Y 32074
EDl7 Clear Med. Base
70W Metal Halide 120.7"H x 97.1'V B4.O'H x 17.0'V 33041
ED17 Clear Med. Base
lOOW Metal Halide 120.7"H x 97.1"V 84.0'H x 16.0'V 33040
ED17 Clear Med. Base
150W Metal Halide 120.7"H x 97.1'V 86.0'H x 1B.O"V 33039
ED17 Clear Med. Base
175W Metal Halide 12O7"N x 97.1'V 86.0'H x 18.0'V 33038
ED17 CIear Med. Base
50OW Quartz 125.4'H x 99.2'V 76.8'H x 24.8'V 39579
T4 Mini-Can
70W High Pressure Sodium 44.3'H x 28.7"Y 22..6'H x 13.1'V 39866
AFL4 ED]7 Clear Med. Base
Oval 49.1'H x 30.9"V 24.9"1' x 14jr"V 39867
100W High Pressure Sodium
Spot
ED]7 Clear Med. Base
150W High Pressure Sodium 63.1"H x 46.0'V 31.9'H x 22.5"V 39868
ED17 Clear Med. Base
7OW Metal Halide 40 5'H x 13.9'V 20.7'H x 6.5'V 39869
ED17 Clear Med. Base
1OOW Metal Halide 49.7"H x 19 0'V 25.8'H x 8.0'V 39870
ED]7 Clear Med. Base
150W Metal Halide 43.5"H x 24.6'V 21.3'H x 10.9'V 3987 1

ED17 Clear Med. Base


175W Metal Halide 44.0'H x 28.2"Y 21.5'H x 11.9'V 39872
EDl7 Clear Med. Base
50OW Quartz 10,450 3x2 42.7'H x 19.3"Y 23.1'H x 9.5'V 39964