Professional Documents
Culture Documents
Ericsson Parameter PDF
Ericsson Parameter PDF
Ericsson SingTel
Dafault Recommended
Parameter Description Range Value Value Remarks
BSPWRB Base Station output power 0 -> 63 dbm 45 45 dBm Note that RBS2301 and 2302 only can supports till 33dbm
GSM 900: 31 to 47dbm In odd
values only 33 to 45dbm In odd
GSM 1800:
Base Station output power for the non-BCCH RF
BSPWRT channel numbers 0 -> 63 dbm 45 Note that RBS2301 and 2302 only can supports till 33dbm
GSM 900: 31 to 47dbm In odd
values only
GSM 1800: 33 to 45dbm In odd
values only
Cell Global Identity (conisists of MCC-MNC-LAC-
CGI CI)
MCC - Mobile Country Code MCC : 3 digits - Parameter is only allowed to be change in cell state HALTED
MNC : 2 or 3 digits depending
MNC - Mobile Network Code Mncdigithand) -
LAC - Location Area Code LAC: 1 to 65535 -
CI - Cell Identity CI : 0 to 65535 -
Base Station Identity Code (consists of NCC-
BSIC BCC)
NCC - Network Coloue Code NCC: 0 to 7 - In Singtel GSM900, we are only allow to use 1, 4 and 6 for NCC
BCC - Base station colour code BCC: 0 to 7 - 0 to 7 BSIC = NCC BCC eg NCC=4 , BSIC will ranges from 40 to 47
BCCHNO Absolute RF channel number for BCCH 1 to 124( GSM900) - - Bcch - Broadcast Control Channel
512 to 885 (GSM1800) - -
BCCHTYPE Type of BCCH
1) COMB - indicates that the cell has a combined
BCCH
2) and SDCCH/4
COMBC - indicates that the cell has a COMB, COMBC, NCOMB NCOMB NCOMB The BCCH is always allocated to time slot number 0 in the defined ARFCN
combined BCCH and SDCCH/4 with CBCH
subchannel ARFCN - Absolute Radio Frequency Channel Number
3) NCOMB - indicates that the cell does not have
any type of combines BCCH and SDCCH/4 CBCH - is used for transmission of messages when the function
Short Messages Service Cell Broadcast (SMSCB) is activate in the cell
CBCH - Cell Broadcast Channel
Parameter is only allowed to be change in cell state HALTED
0 to 7 if non-combined Bcch is
AGBLK Number of reserved access granted blocks used 1 1 AGBLK Parameter is only allowed to be change in cell state HALTED
0 to 2 if combined Bcch and
SDCCH/4 is used
To prevent that all cells on a site send BCCH channels at the same time it is possible
to define a deviation with respect to the FN generator called FNOFFSET. By using
Frame Number Offset - Indicates the time FNOFFSET on a synchronised two or three sector site the time for decoding BSIC
FNOFFSET difference from the FN generator in the BTS 0 to 1325 TDMA Frames 0 0 TDMA Frame can be reduced. RBS2000 and 200 only support the range 0 to 1023.
Early Classmark Sending Control - indicates if an
ECSC MS in the cell is allowed to use No - Early sending is not allowed Yes YES The parameter ECSC has to be set to YES in order to allow the MS to send the
early classmark Sending. Yes - Early sending is allowed MS mutliband and/or multislot capability.
STATE Cell or Channel Group state ACTIVE, HALTED - ACTIVE The cell or channel group is active or halted
HOP Frequency hopping status ON, OFF, TCH TCH TCH SDCCHs as well as TCHs can hop.
ON: The hopping status for the channel group is
hopping for TCH and SDCCH A bcch will not hop even if it belongs to a channel group defined as hopping
OFF: The hopping status for the channel group is
non hopping
TCH: The hopping status fpr the channel group is
hopping for TCH only
DCHNO Absolute RF channel number 1 to 124( GSM900) - 32 ARFCN GSM900: max 31 DCHNO, GSM1800: max 31 DCHNO, GSM1900: max 31 DCHNO
Related to BCCH plan 512 to 885 (GSM1800)
SDCCH Required number of SDCCH/8 0 to 16 1 1 sdcch Refer to notes for different types of configurations
SCHO SDCCH handover switch ON, OFF OFF OFF ON - handovers on SDCCH are allowed; OFF - handovers on SDCCH are not allowed
DTXD Discontinuous Transmission Downlink ON, OFF OFF OFF Note: ON: DTX DL is enabled for the cell; OFF: DTX DL is disabled for the cell
DTXU Uplink DTX indicator 0 to 2 1 1 Uplink discontinuous transmission means that the MS does not
0: The MSs may use uplink discontinuous
transmission transmit continuously, but only when necessary, thus being able
1: The MSs shall use uplink discontinuous
transmission to save batteries
2: The MSs must not use uplink discontinuous
transmission
MAIO Mobile Allocation Index Offset 0 to 15 or DEFAULT DEFAULT DEFAULT SingTel using Baseband Hopping for GSM900 System, RF Hopping for GSM1800
FHOP Frequency Hopping BB, SY BB
BB: Baseband hopping
SY: Synthesiser hopping
Subcell type. SingTel does not use Intelligent UL The subcell type is underlaid.
SCTYPE Underlay Overlay [IUO] UL, OL - - OL The subcell type is overlaid.
DOUBLE BA List
MBCCHNO is the BCCH allocation, i.e. it indicates to the MS the frequencies that
Absolute RF channel number for measurement on must be monitored and measured in idle, active or both modes.Up to 32 BCCH carriers
MBCCHNO BCCH 1 to 124 (GSM900) - 32 BCCH in the List can be defined by specifying their ARFCN
identifies which type pf list the chosen 512 to 885 (GSM1800)
LISTTYPE frequencies will be on IDLE, ACTIVE, Omited - IDLE/ ACTIVE
Extended range
Radio Link Time-out - the maximum value of the RLINKUP is used by the BSC to determine when to disconnect the call upon
RLINKUP radio counter for the uplink 1 to 63 SACCH periods (480ms) 16 16 repeated failure in decoding the SACCH.
A counter that is given the value RLINKT is started in the MS
after the assignment of a dedicated channel. Two units increase
the counter if the SACCH data is successfully decoded. One
Radio Link Time-out - the maximum value of the 8 to 64 in steps of 4 SACCH unit decreases it if it cannot be successfully decoded. If the
RINKT radio downlink counter periods (480ms) 16 16 counter reaches the value zero, then the call release is initiated.
If the measured timing advance value for an access burst is
Maximum timing advance before an MS is equal to or greater than MAXTA, then the connection set-up
MAXTA considered lost 0 to 63 (normal cell) 63 63 signalling is terminated by the system.
MS power control
DMPSTATE Dynamic MS power control state ACTIVE, INACTIVE INACTIVE ACTIVE
Defines the target value for the desired signal
strength uplink measured by the BTS during the
SSDES stationary phase. 47 to 110 dbm 85 95 dBm Lower desired SS to prevent interference in Urban Area
Defines the target value for the desired signal
strength uplink measured by the BTS during the
INIDES initial phase. 47 to 110 dbm 70 85 dBm
SSLEN Length of stationary signal strength filter 3 to 15 SACCH periods 5 5 SACCH The value of SSLEN > INILEN.
INILEN Length of initial signal strength filter 0, 2 to 5 SACCH periods 2 2 SACCH Faster when value is lower
Path loss compensator factor, uplink. When set
LCOMPUL to zero, no power control towards SSDES is 0 to 100% 70 30%
Power margin on the new channel at assignment,
intra-cell handover and subcell change and on the
old channel at assignment failure or handover
PMARG failure. 0 to 20 dB 8 3 dB
QDESUL Desired quality uplink 0 to 70 dtqu 20 35 dtqu
QLEN Length of the uplink quality filter 1 to 20 SACCH periods 8 12 SACCH
QCOMPUL Quality deviation compensation factor, uplink 0 to 60 % 30 30%
MS power regulation is performed at intervals specified by REGINT. A new power
order is issued only if the calculated power level is different from the current MS
REGINT Regulation interval, stationary, uplink 1 to 30 SACCH periods 3 3 SACCH power level.
Number of measurements periods before the full
DTXFUL set of measurements are used 0 to 40 SACCH periods 5 5 SACCH
Ericsson 3
Signal strength hysteresis when evaluating high
HIHYST signal strength cells 0 to 63 db 5 dB 5 dB
Signal strength hysteresis when evaluating low
LOHYST signal strength cells 0 to 63 db 3 dB 3 dB
Signal strength separator for high and low
HYSTSEP signal strength cells 0 to 150 dbm 90 dBm 90 dBm
The parameter is represented by OFFSETN, if the value is in the range (63, -