Wind Mast Instruments

Technical Specification
Item. Remark
Description Qty Unit Unit Price Total Price
No
Anemometer
The anemometer is expected to be of scientific
quality and highest accuracy. The anemometer
should satisfy the requirements of IEC 61400-
12-1
1 Class A: < 1.5 30 Set
Class B: < 4.5
Accuracy: 1% in the range 0.5 to 50 m/s
Starting velocity: <0.3 m/s
Measuring range: 0.3 to 75 m/s
Survival speed: 80 m/s
Wind Vane
Digital wind vane of the type Tunnel Magneto
Resistance (TMR),
2 10 Set
Fine resolution 10 and covers entire 3600
without North gap,
Accuracy of 10
Pyranometer
The pyranometer is expected to be of scientific
quality and highest accuracy.
Secondary Standard according to the ISO 9060
standard.
Response time: < 15s
3 Zero-offset: 6 Set
Offset-A: + 7 W/m
Offset-B: 2 W/m
Non-stability: 0.8%
Non-linearity: 0.5%
Directional response (for beam irradiance):
10 W/m

Page 1 of 3
Spectral selectivity: 3%
Temperature response: 2%
Tilt response: 0.5%
Temperature and Humidity sensor
Compact temperature and humidity sensor with
high accuracy,
Temperature sensor Pt100
Humidity sensor capacitive type
4 6
Measuring range: temperature -20 to +700C Set
humidity 0 to 100% RH
Accuracy: temperature 0.2 K
Humidity 2% RH
Wind and sun protection shield included.
Barometric Pressure
Piezoelectric sensor type mounted in stainless
steel housing.
Operating pressure: 600 to 1100 hPa
5 6 Set
Altitude: up to 3500 m
Operating range: temperature -20 to +700C
humidity 0 to 98% RH
Accuracy: 2% of full scale output
Solar Module
Monocrystalline solar module for standalone
power supply of instruments.
High quality tempered glass and anodized
6 6 Set
aluminum frame.
Peak power; 50 W/ 12 V
Vmp: 18 V, Voc: 22 V
Imp: 2.75 A, Ioc: 3 A
Solar Controller
The controller function is to monitor the
charging of battery and controls charging
7 process. Includes: 6 Set
Overcharge protection,
Deep discharge protection,
Battery under voltage protection,

Page 2 of 3
Solar module reverses current protection.
System voltage: 12 V
Module/Load current: 8 A
Own consumption: < 4 mA
Operating range: temperature -20 to +700C

Data Logger
The data logger is expected to accommodate
data connection to instruments specified above:
minimum of 6 anemometers, 2 wind vanes, 1
temperature sensor, 1 humidity sensor, 1
pressure sensor and 1 pyranometer.
Communication:
Local: able to access through LAN or USB
Remote: at least be able to connect through
8 6 Set
GSM
Data Transfer: able to transfer data through
reliable and secure HTTPS data transfer.
Input channels:
Digital: minimum 8
Analog: minimum 12
Output channels: minimum 4
Storage size: 2 GB
Including all weather steel cabinet.

Battery
Solar deep cycle battery storage to store and
9 supply power to the instruments. 6 Set
Voltage: 12 V
Capacity: 230 Ah

NB. ::

Page 3 of 3