You are on page 1of 15

LTE Key Configurations with

RRUS12
Legend
CPRI: Optical GSM
e CPRI: electrical
CPRI: Optical LTE
o CPRI: Optical
CPRI: Optical Bitween Data 1 & Data 2
IDL
GPS IDL 2 : Electrical Ethernet cable
e CPRI: electrical
GPS OUT
o CPRI: Optical
NTP Sync
Configuration Type A
1(L)
RRUS12 B3 1(L)
Sector 1

RRUS12 B3 1(L)
Data1
RRUS12 B3
Sector 2

o Data2 Data1

Sector 3
o Data2 Data1
Data2

Standalone LTE implementation


No changes to existing 2G

DUS31
o o o
GSM 4+4+4
Configuration Type B DCS 4+4+4,20W
MU-2,DUG 2
4(G) + 1(L)
RRUS12 B3 DUS41 - 1
Sector 1

4(G) + 1(L)
Data1
RRUS12 B3
o Data2 2(G) + 1(L)

Sector 2
Data1 RRUS12 B3

o Data2

Sector 3
Data1
Data2

DUG20
o o 0
DCS 4+4+2
DUG20
o o o
GSM 4+4+4

DUS31
o o o

RRUS 01 B8
[4+4+4]
Configuration Type B
Standard multi standard mixed mode
N number ofDUS41 card will extend their GPS out
synchronization signal to N number of DUG cards serving for
DCS. (N=1 or 2, in this project)
GSM can be available on not and that will only be a
dependency for the number of MUs going to be added
DUS41/s could be install in the same MU or in separate MUs
where DUGs are installed which are serving for DCS
There could be more than one RRUS [Two] per sector and one
of them could be DCS only.
GSM 4+4+4+4
Configuration Type C DCS 6+8+10
4(G) + 1(L) MU-3,DUG 4
2(G)
RRUS12 B3
RRUS12 B3
DUS41 - 1
Sector 1

4(G) + 1(L)
Sector 1
Data1
RRUS12 B3
4(G)
o Data1 RRUS12 B3
o Data2 4(G) + 1(L)

Sector 2
Data2
6(G)

Sector 2
Data1 RRUS12 B3
o Data1 RRUS12 B3
o Data2

Sector 3
Data2

Sector 3
Data1
o Data1
Data2
Data2

DUG20 DUG20
e o o e e o o
DCS 6 DCS 10
DUG20 DUG20
o e o o o o
DCS 8+GSM 4 GSM 4+4+4

DUS31
o o o
RRUS 01 B8
[4+4+4+4]
Configuration Type C
Extended multi standard mixed mode
N number ofDUS31 card will extend their GPS out
synchronization signal to M (>N) number of DUG cards serving
for DCS. (N=1 or 2, in this project)
GSM can be available or not and that will only be a
dependency for the number of MUs going to be added
DUS31/s could be install in the same MU or in separate MUs
where DUGs are installed which are serving for DCS
There could be more than one RRUS [Two] per sector and one
of them could be DCS only.
The IDL2 port support would be available after Q2 2014.