Ultrasonic Examination Report


Job Deseription:-
Client:- EchaarEquipments P Ltd ReportDate:- 09.07.2017
Test Report No:- OM/EEPUl 7-18/541 Supplier Name -
Project:- Location of Work Site :- Bhiwandi
Test Date:- 09.07.2017 Job Details & Technique:- Plate Testing
Material Specification:- S355J2+N Equipment.-
DGRNO- QAPNo-
Ultrasonic Flaw Detection Technique Details:
Equipment Model PXUT -350C Machine Make UNION
Mic Sr.No R10607 Mic Calibration Date 24.12.2016
Test Probe Details:
Probe Type Angle of Probe Frequency Probe Size Range Setting Reference Db Scanning Db
Normal Probe 0 2MHZ 24Diameter Oto200mm 63Db 69Db
Scanning Details:-
Calibration Block Nos. VI & V2Block Reference Reflectors As Per ASME Sec V Art- 4&5
Couplet Water Reference Level As Per SA578 Level-B
Extent of Examination 100% Recording Level As Per SA578 Level-B
Surface Condition As Smooth Disregard Level As Per SA578 Level-B
References Block No ----- Flaw Sizing Technique Manual Contact
Reference Document"s:-
Ultrasonic Test Specification As Per ASME Sec V Art- 4&5
UT Procedure No
Acceptance As Per SA578 Level-B
TEST RESULTS
Sr. Job Desecription Heat No Qty Flaw I
Indication Size I
Observation Result
No Location
01 Plate Size 80x2020x6040 H-16410969N3 I Nos No Recordable Indication was Observed Acceptable
02 Plate Size 80x2020x6040 H-16411095N3 I Nos No Recordable Indication was Observed Acceptable
03 Plate Size 80x2020x6040 H-16410968N3 I Nos No Recordable Indication was Observed Acceptable
Remarks:-
Name Of UT Operator:-Mr.AjayPatil NDT UT Level -II
UT Performed BY. '"'JIL Authority Witness
AJAY Pl"\
~~OT Level-II
~ tUT/fviP.,./LPT/~T
ND UT LEVEL tr '

'