Job Deseription:- Client:- EchaarEquipments P Ltd ReportDate:- 09.07.2017 Test Report No:- OM/EEPUl 7-18/541 Supplier Name - Project:- Location of Work Site :- Bhiwandi Test Date:- 09.07.2017 Job Details & Technique:- Plate Testing Material Specification:- S355J2+N Equipment.- DGRNO- QAPNo- Ultrasonic Flaw Detection Technique Details: Equipment Model PXUT -350C Machine Make UNION Mic Sr.No R10607 Mic Calibration Date 24.12.2016 Test Probe Details: Probe Type Angle of Probe Frequency Probe Size Range Setting Reference Db Scanning Db Normal Probe 0 2MHZ 24Diameter Oto200mm 63Db 69Db Scanning Details:- Calibration Block Nos. VI & V2Block Reference Reflectors As Per ASME Sec V Art- 4&5 Couplet Water Reference Level As Per SA578 Level-B Extent of Examination 100% Recording Level As Per SA578 Level-B Surface Condition As Smooth Disregard Level As Per SA578 Level-B References Block No ----- Flaw Sizing Technique Manual Contact Reference Document"s:- Ultrasonic Test Specification As Per ASME Sec V Art- 4&5 UT Procedure No Acceptance As Per SA578 Level-B TEST RESULTS Sr. Job Desecription Heat No Qty Flaw I Indication Size I Observation Result No Location 01 Plate Size 80x2020x6040 H-16410969N3 I Nos No Recordable Indication was Observed Acceptable 02 Plate Size 80x2020x6040 H-16411095N3 I Nos No Recordable Indication was Observed Acceptable 03 Plate Size 80x2020x6040 H-16410968N3 I Nos No Recordable Indication was Observed Acceptable Remarks:- Name Of UT Operator:-Mr.AjayPatil NDT UT Level -II UT Performed BY. '"'JIL Authority Witness AJAY Pl"\ ~~OT Level-II ~ tUT/fviP.,./LPT/~T ND UT LEVEL tr '