You are on page 1of 2

 

                       GENSET  MAINTENANCE  CHECK  LIST

BRANCH : TANGGAL  PEMERIKSAAN :


MERK : TYPE : YEARS :
CAPACITY : kVA POWER  PLN : Kva
INSPECTION  ITEM STANDARD DATA REMARKS

1.  Tegangan  (Voltage)
       *  Output  Genset a.  RN  =                                              Volt a.  RS  =                                              Volt
b.  SN  =                                              Volt b.  ST  =                                              Volt
3  Phase c.  TN  =                                              Volt c.  TR  =                                              Volt
(375V-­‐383V)
       *  PLN  (Panel  ATS) a.  RN  =                                              Volt a.  RS  =                                            Volt
b.  SN  =                                              Volt b.  ST  =                                              Volt
1  Phase c.  TN  =                                              Volt c.  TR  =                                              Volt
2.  Arus  listrik  berbeban  (Ampere  Load)  
(Waktu/jam  pada  saat  pengukuran) a.  R  =                                                  Amp b.  S    =                                    Amp
c.  T    =                                                Amp d.  N    =                                    Amp
3.  Grounding
         a.  Pengukuran  Grounding  (N-­‐E)
         *  Panel  MDP X  <  1  Volt volt
         *  Panel  UPS X  <  1  Volt volt

         b.  Koneksi  Grounding  (Connectivity)                    Terpisah  dengan  Grounding  Listrik  Utama


         *  Genset                    Menyatu  dengan  Grounding  Listrik  Utama
                   Tidak  ada  Grounding  (NA)

4.  Frekwensi  (Frequency)
48-­‐53  Hz
Hz
5.  Running  Test
         *  Berbeban  (Load) 5  -­‐  10  mnt                    Normal                    Tidak  Normal  (malfunction)
         *  Tanpa  berbeban  (UnLoad) 5  -­‐  10  mnt                    Normal                    Tidak  Normal  (malfunction)
6.  Pemakaian  Mesin  (Runing  Hour) Jam  (Hour)
7.  Lampu  Indicator  (Indicator  Lamp) Menyala                    Menyala                    Mati  (Damage)
8.  Fungsi  Tombol  Darurat  (Emergency  Func.) Berfungsi                    Berfungsi                    Tidak  Normal  (malfunction)
9.  Kondisi  Radiator  (Radiator  Condition)
         *  Volume  Air  Radiator  (Radiator  Coolat) Batas  Normal                    Normal                    Rendah  (Low)
         *  Suhu  Running  (Temperature) 65  -­‐  85  °C °C
         *  Air  Radiator 1  Tahun                    Ganti                    Tidak
10.  Udara  Masuk  (Air  Intake)                    Bersih                    Kotor                        Ganti
         a.  Kondisi  Filter  Udara  (Air  Filter  Condition) Bersih
                             Bersih                    Kotor                        Ganti
         b.  Kondisi  Turbocharger  (Turbocharger  Con.) Bersih  1000  Jam                    Servis                    Tidak
11.  Kondisi  Accu  (Accu  Cond.)
Low Med Hi
         *  Air  Accu  (Water  Levelling) Batas  Normal
         *  Tegangan  sebelum  start  (Voltage  before  Start) 11-­‐14  Vdc Volt  (Volt)
         *  Tegangan  starting  (Voltage  Starting) 10-­‐12  Vdc Volt  (Volt)
12.  Battery  Charger
         a.  Tegangan  Input  PLN 220  V Volt  (Volt)
         b.  Tegangan  Ouput  Battery 13-­‐14  V Volt  (Volt)
         c.  Arus  Batt.  Charger 0.5  -­‐  2A      A  (Ampere)

         d.  Kinerja  Batt.  Charger  (Batt.  Charger  Func.) Normal                    Normal                    Rusak  (malfunction)
13.  Kondisi  Oli  (Oil  Condition)
Low Med Hi
         a.  Level  Oli  (Oil  Condition) Normal
         b.  Tekanan  Oli  (Oil  Pressure) >25Psi Psi
         c.  Kepekatan  Oli Encer                    Encer                    Pekat                      Kotor
         d.  Filter  Oli 200  Jam/3  Bulan                    Ganti                    Tidak
         e.  Oli 200  Jam                    Ganti                    Tidak
14.  Selang  /  Pipa  (Pipe)
         a.  Kondisi  Pipa  Air  Pendingin Baik                    Baik                    Rusak
         *  Service 2000  Jam                    Ganti                    Tidak

         b.  Kondisi  Pipa  Bahan  Bakar Baik                    Baik                    Rusak


         *  Service 2000  Jam                    Ganti                    Tidak
15.  Blok  Mesin
         a.  Fan Berfungsi                    Berfungsi                    Tidak
         b.  Roda  Gila Berfungsi                    Berfungsi                    Tidak
         c.  Altenator Berfungsi                    Berfungsi                    Tidak
         d.  Koneksi  Terminal Erat                    Erat                    Tidak  Erat
         e.  Kondisi  Terminal Bersih                    Bersih                    Kotor/Karat
         f.  Dynamostater Berfungsi                    Berfungsi                      Tidak                    Ganti
16.  Bahan  Bakar  (Gasoline)
         *Kapasitas  (Gasoline  Level) Max                              Min                                                  Max
Min  40  Lt
         *Cadangan  (Spare) Liter  (Litre)

         *  Filter  Bahan  Bakar 200  Jam  /  3  Bulan                    Ganti                    Tidak


17.  Change  Over  Switch  (COS) A                  
         *  Kapasitas  (Capacity)
         *  Koneksi  Kabel  (Connection  Cable) Erat                    Erat                    Tidak  Erat
18.  Panel  AMF  (AMF  Pannel)
         *  Warming  up  time Senin  &  Kamis                    Normal                    Tidak  Normal  
10:00  -­‐  10:10
         *  Koneksi  Kabel  (Connection  Cable) Erat                    Erat                    Tidak  Erat

         *  Kinerja  AMF  (AMF  Func.) Normal                    Normal                    Tidak  Normal  (malfunction)


19.  Panel  ATS  (ATS  Pannel)
         *  Koneksi  Kabel  (Connection  Cable) Erat                    Erat                    Tidak  Erat
         
         *  Kinerja  ATS  (ATS  Func.) Normal                    Normal                    Tidak  Normal  (malfunction)
19.  Panel  MDP  (MDP  Pannel)
         *  Koneksi  Kabel  (Connection  Cable) Erat                    Erat                    Tidak  Erat
21.  Kebersihan
         a.  Blok  Mesin Bersih                    Bersih                    Kotor
         b.  Panel  AFM Bersih                    Bersih                    Kotor
         c.  Panel  ATS Bersih                    Bersih                    Kotor
         d.  Panel  MDP Bersih                    Bersih                    Kotor
         e.  Body  Genset Bersih                    Bersih                    Kotor
         f.  Lingkungan  Genset Bersih                    Bersih                    Kotor
Keterangan  /  Temuan  /  Tindakan  Perbaikan  (Description  /  Finding  /Corrective  Actions)  : Mengetahui  BSM
(Client  Signature)

Pelaksana  (JLL)

(Technician  JLL)

No.  Work  Order  (WO)  :