Main Functionality of an Automotive Control Unit


Î Main task: Fulfill its controlling functionality (e.g. control transmission unit)
Î Measure and collect the needed data for its main tasks
Î Check and filter the incoming / measured signals
Î Detect and log errors
Î In case of error – according to the type – surmount error, or restrict
functionality
Î Configuration interface
Î Automatic adaptation to environment
Î Protection against stealing / manipulation
Î Fulfill international and local standards
Î Programmable / Patchable
Î Provide information to other control units
Î Communicate with an external tester

2 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

1
Debreceni Egyetem - Informatikai Napok

Goals of the Diagnostic Communication I.


Î Main task: Fulfill its controlling functionality
Î Measure and collect the needed data for its main task
z Continuous observation of the control unit
z Check reactions of the control unit
Î Check and filter the incoming / measured signals
Î Detect and log errors
z Read error memory (source of the error, art and status)
z Check reliability of incoming / measured signals

3 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Goals of the Diagnostic Communication II.


Î In case of error: surmount error or restrict own functionality according to
the type of error
z Read out error code

z Provide information to find the source of the error

Î After fixing error clear error memory


Î Provide information to other control units
Î Configuration interface
z Read and write configurable parameters (adapting to the other control

units or local law)


Î Automatic adaptation to environment
z Be able to clear learning values

4 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

2
Debreceni Egyetem - Informatikai Napok

Goal of the Diagnostic Communication III.


Î Protection against stealing / manipulation
z Authentification of ignition key and other control units

z Chip-tuning protection

Î Programmable / Patchable
z The main part of the control unit SW can be reprogrammed

Î Should fulfill international and local standards


z CARB (Californian Air Resource Board) /

z OBD (OnBoard Diagnostic)

z EOBD (European OnBoard Diagnostic)

z KOBD (Korean OnBoard Diagnostic)

z ISO 14229 / ISO 14230 / ISO 15031 / ISO 15765 / ISO 11898

z …

5 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Vehicle Network Architecture in a High End Car


D-CAN E/E-Infrastructure
FlexRay
CAN
CGW

Ethernet
W-LAN
USB
BCM1 BCM2 THU Ethernet
VMM PSM EPM
CAN
MOST CAN
TV LRR ESP
AMP
SRR1 EPB ETC
Instr.
DAB/
SDARS SRR2 EPS
S/G
Disp. Video DLC
LIN ...
CDC BM
Disp. PSI5

ARS

Body Infotainment Vehicle Passive Power


& Comfort & Cockpit Motion Safety Train
Electronics Electronics Electronics Electronics Electronics

GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
6 Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

3
Debreceni Egyetem - Informatikai Napok

Communication System in the Vehicle


Position Lever Unit Porsche Cayman

Engine Control Unit

Brake Control Unit Display Unit

Transmission Control Unit

GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
7 Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

8 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

4
Debreceni Egyetem - Informatikai Napok

K-Line Layer 1
Vehicle Tester
Battery (~14,4V)

K-Line

ECU1 ECU2 ECUn

GND

9 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

K-Line Layer 1
Î Logical 0:
z K-Line is under 20% of battery voltage at transmitter side
z K-Line is under 30% of battery voltage at receiver side

Î Logical 1:
z K-Line is above 80% of battery voltage at transmitter side
z K-Line is above 70% of battery voltage at receiver side

10 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

5
Debreceni Egyetem - Informatikai Napok

K-Line Layer 2: Overview


Î No continuous communication: must be initialized by tester (WUP or
5BaudInit)
Î No communication between the control units
Î Each host has one or more fix addresses; multicasting is also possible
Î Fixed Baud-rate at start of the communication (10.4 kBaud), it can be
changed (until 250kBaud)
Î Defined but configurable timeout values for communication session,
request – response, response – next request separation time
Î Initialization phase determines several format parameters of the further
communication
Î Arbitration: CSMA/CD

11 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

K-Line Layer 2: Initialization


WUP StartComm Communication

25ms

50ms

Client Server
WUP StartComm Communication

25ms

50ms

Client ServerX Server1 Server2 ServerN

12 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

6
Debreceni Egyetem - Informatikai Napok

K-Line Layer 2: Message Structure


Header Data bytes Checksum

Fmt Tgt1) Src1) Len1) SId2) Data


2)
CS

max. 4 bytes max. 255 bytes 1 byte

Checksum calculation

1) Byte is optional, depending on format byte.


2) Service identification, part of data bytes.

F F L L L L L L

13 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000 – K-Line, Layer 5-7: Service IDs


Header Data bytes Checksum

Fmt Tgt1) Src1) Len1) SId2) Data


2)
CS

max. 4 bytes max. 255 bytes 1 byte

Checksum calculation

0x01 – 0x3E, 0x80 – 0xBF: Possible Service IDs


SID + 0x40: positive response
0x7F: negative response

14 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

7
Debreceni Egyetem - Informatikai Napok

KWP2000 – K-Line, Layer 5-7: Service IDs: Example

Tester C1 33 F1 81 CS

TCU 83 F1 18 C1 XX XX CS

Tester C2 33 F1 21 XX CS

TCU 8x F1 18 61 XX … XX CS

Motronic 8x F1 10 61 XX … XX CS

ECUx 83 F1 XX 7F 21 31 CS

15 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

K-Line CAN
Î Reserved for diagnostic Î Diagnostic & continuous
communication communication between ECUs
Î Longer data packets can be Î A CAN frame is max. 8 bytes:
transmitted encapsulation of request required
Î Configurable communication Î Fixed speed: because of the
speed continuous bus configuration
Î Arbitration must be implemented Î Bus arbitration, CAN-frame
by SW (UART) structure is handled by HW
Î Additional wire + HW Î Wire + required HW component
Component (Layer1) already exists
Î Additional SW Driver for Layer 2 Î SW Drivers already exist, only sw
of diagnostic communication
must be implemented

16 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

8
Debreceni Egyetem - Informatikai Napok

CAN Layer 1 and Layer2


Î Defined by ISO 11898

17 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

CAN Layer 3 and Layer4

CAN ID dlc Data


SF 0xXXX 2-8 N_PCI 0xXX 0xXX 0xXX 0xXX 0xXX 0xXX 0xXX

FF 0xXXX 8 N_PCI 0xXX 0xXX 0xXX 0xXX 0xXX 0xXX


FC 0xXXX 3-8 N_PCI -- -- -- -- --
CF 0xXXX 2-8 N_PCI 0xXX 0xXX 0xXX 0xXX 0xXX 0xXX 0xXX

0x0L : L=Length of Data (4 bit) 0x1L LL : L=Length of Data (12 bit)

0x3F BB SS
F: FlowControll Status 0x2N : N=SequenceNumber
B: BS: max number of CF without FC
S: STmin follow-up time of CFs

18 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

9
Debreceni Egyetem - Informatikai Napok

KWP2000 over CAN

CAN ID dlc Data

Tx 0x7DF 8 0x02 0x10 0x81 0xXX 0xXX 0xXX 0xXX 0xXX


Rx 0x7E9 8 0x02 0x50 0x81 0xXX 0xXX 0xXX 0xXX 0xXX

Tx 0x7DF 8 0x02 0x21 0x80 0xXX 0xXX 0xXX 0xXX 0xXX


Rx 0x7E9 8 0x10 0x0A 0x61 0x81 0x01 0x02 0x03 0x04
Tx 0x7E1 8 0x30 0x00 0x00 0xXX 0xXX 0xXX 0xXX 0xXX
Rx 0x7E9 8 0x21 0x05 0x06 0x07 0x08 0xXX 0xXX 0xXX

19 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

20 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

10
Debreceni Egyetem - Informatikai Napok

Purpose of the Services


Î Diagnostic and Communication Management
Î Data Transmission
Î Stored Data Transmission
Î Input / Output Control
Î Remote Activation of Routine
Î Upload / Download
Î CARB / OBD / EOBD / KOBD

21 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
StartDiagnosticSession (0x10) DiagnosticSessionControl (0x10)
Î Sets diagnostic session: this Î Sets diagnostic session: this
session determines the session determines the availability
availability of other services of other services
Î Prepares jump to other SW parts Î Prepares jump to other SW parts of
of the ECU the ECU
Î Over K-Line: change Baud-rate Î May change timing values (not
StopDiagnosticSession (0x20) configurable)
Î Enables or sets back
SecurityAccess
Î Can reactivate deactivated CAN
communication, deactivated error
storing
Î Resets responseOnEvent

22 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

11
Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
ECUReset (0x11) ECUReset (0x11)
Î After checking preconditions Î After checking preconditions
restarts the ECU software restarts the ECU software
Î Reset type may be hard or key-on- Î Reset type may be hard, key-on-off,
off soft, enable / disable
rapidPowerDown

TesterPresent (0x3E) TesterPresent (0x3E)


Î Keeps communication alive: avoid Î Keeps communication alive: avoid
communication timeout communication timeout

23 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
SecurityAccess (0x27) SecurityAccess (0x27)
Î Authentication of the tester, restrict Î Authentication of the tester, restrict
access access
Î May define different security levels Î May define different security levels
Î Valid during the communication Î Valid only at the activated
period diagnostic session or
communication period

AccessTimingParameters (0x83) AccessTimingParameters (0x83)


Î Timeout values and message Î Timeout values and message
separation time can be read / written separation time can be read /
written

24 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

12
Debreceni Egyetem - Informatikai Napok

KWP2000
ReadECUIdentification (0x1A)
Î The tester requests only a LocalID
Î The ECU provides information about itself, e.g. SW and HW IDs,
versions, other logistic data

25 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

UDS
CommunicationControl (0x28)
Î Activate / Deactivate sending and receiving CAN Frames for/from other
ECUs (vehicle internal communication)
Î Increases bandwidth for flash programming; prevents CAN timeout errors
Î Does not deactivate diagnostic CAN channel

SecuredDataTransmission (0x84)
Î This service encapsulates another service
Î Security SubLayer of the transmitter encodes the encapsulated service
Î Security SubLayer of the receiver decodes the encapsulated service

26 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

13
Debreceni Egyetem - Informatikai Napok

UDS
ControlDTCSettings (0x85)
Î Activate / Deactivate storing of errors into error memory
Î Used at flash programming and development

ResponseOnEvent (0x86)
Î Configures the ECU to send a response without a request in case of a
defined event
Î Permanent and temporally configuration

LinkControl (0x87)
Î Configures communication speed, if the medium is configurable

27 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Example: Starting of Flash Programming


Func: 0x10: ExtendedSess Phys: 0x10: ProgSess

Preconditions Phys: 0x27 RequestSeed


Yes
Func: 0x85
Phys: 0x27 RequestSeed

Preconditions
Yes Auth. OK

Func: 0x28 Yes

Yes Prog
Preconditions

28 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

14
Debreceni Egyetem - Informatikai Napok

Purpose of the Services


Î Diagnostic and Communication Management
Î Data Transmission
Î Stored Data Transmission
Î Input / Output Control
Î Remote Activation of Routine
Î Upload / Download
Î CARB / OBD / EOBD / KOBD

29 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000 and UDS


ReadMemoryByAddress (0x23)
Î The tester requests a memory address and number of bytes
Î The ECU – if authentification level allows – reads out the block
Î The format of the request is different at KWP2000 and UDS
WriteMemoryByAddress(0x3D)
Î The tester sends a memory address, and number of bytes and a data
string (according to the number of bytes )
Î The ECU writes the data string into its memory
Î The format of the request is different at KWP2000 and UDS

30 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

15
Debreceni Egyetem - Informatikai Napok

KWP2000
ReadDataByLocalIdentification (0x21)
Î The tester requests one or more LocalIDs (1 byte long ID)
Î A localID identifies a part of memory (not necessarily in one block)
Î The ECU – if authentification level allows – reads out the block
Î These IDs identifies mainly pre-defined memory parts, but dynamic
definition is also allowed
Î A localID must not be unique within a vehicle
Î LocalID can be read out periodically
WriteDataByLocalIdentification (0x3B)
Î The tester sends a localID (1 byte long ID) and a data string
Î The ECU writes the data string into its memory

31 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000
SetDataRate (0x26)
Î If any data is requested periodically, the repetition of the response can be
fast, medium or slow
Î This message defines, what does “fast”, “medium” and “slow” means

32 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

16
Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
ReadDataByCommonID (0x22) ReadDataByID (0x22)
Î Similar to readDataByLocalID ReadScaleingDataID (0x2D)
(0x21) Î Descendant of KWP2000 0x1A,
Î CommonID is 2 bytes long, but 0x21 and 0x22
unique or means the same for Î The same as KWP2000 0x22, but
more ECUs periodical read not supported
WriteDataByCommonID (0x2E)
Î Similar to writeDataByLocalID WriteDataByID (0x2E)
(0x3B)
Î The same as KWP2000 0x2E
Î CommonID is 2 bytes long, but
unique or means the same for
more ECUs

33 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
DynamicallyDefineLocalD (0x2D) DynamicallyDefineDataID (0x2D)
Î The tester requests one or more Î The tester requests one or more
memory addresses and length, memory addresses and length,
AND/OR LocalIDs, AND/OR AND/OR dataIDs
CommonIDs
Î The ECU orders the requested Î The ECU orders the requested
memory parts to a dynamic LocalID memory parts to a dynamic DataID
Î By requesting that dynamic ID Î By requesting that dynamic ID
internal data can be read out with internal data can be read out with
low CPU overload low CPU overload
Î dynamicallyDefinedLocalID can be Î dynamicallyDefinedLocalID can be
erased erased

34 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

17
Debreceni Egyetem - Informatikai Napok

UDS
ReadDataByPeriodicID (0x2D)
Î Similar to ReadDataByID
Î The response is periodical

35 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Purpose of the Services


Î Diagnostic and Communication Management
Î Data Transmission
Î Stored Data Transmission
Î Input / Output Control
Î Remote Activation of Routine
Î Upload / Download
Î CARB / OBD / EOBD / KOBD

36 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

18
Debreceni Egyetem - Informatikai Napok

Onboard Diagnostic
Start

Input Signal Signal is analog or digital

Yes
Signal Reliable? Fulfills filter criteria; open/short-
circuited, timeout
No
Inc. counter Dec. counter

No
Cnt. threshold reached?
Yes
Beside the error code the type of the error, the
Write error to actual status; and actual value of some related
error memory signals are also stored

37 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
ReadDiagnosticTroubleCode ReadDTCInformation (0x19)
(0x13) Î Error memory queries, by different
ReadDiagnosticTroubleCodeBy filtering criteria
Status (0x18) Î The filtering criteria is sent by the
sub-function of the service
ReadStatusOfDiagnosticCode
(0x17)
ReadFreezeFrameData (0x12)
Î Error memory queries, by different
filtering criteria

38 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

19
Debreceni Egyetem - Informatikai Napok

KWP2000 and UDS


ClearDiagnosticInformation (0x14)
Î Clears one, a group of, or all the stored errors from error memory

39 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Purpose of the Services


Î Diagnostic and Communication Management
Î Data Transmission
Î Stored Data Transmission
Î Input / Output Control
Î Remote Activation of Routine
Î Upload / Download
Î CARB / OBD / EOBD / KOBD

40 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

20
Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
InputOutputControlByLocalID InputOutputControlByIdentifier
(0x30) (0x2F)
InputOutputControlByCommonI Î Can directly control the actuator
D (0x2F) signals
Î Can directly control the actuator Î Access to actuators is application-
signals specific
Î Access to actuators is application-
specific

41 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Purpose of the Services


Î Diagnostic and Communication Management
Î Data Transmission
Î Stored Data Transmission
Î Input / Output Control
Î Remote Activation of Routine
Î Upload / Download
Î CARB / OBD / EOBD / KOBD

42 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

21
Debreceni Egyetem - Informatikai Napok

KWP2000 UDS
StartRoutineByLocalID (0x31) RoutineControl (0x31)
StartRoutineByAddress (0x38) Î Controls routines, as erasing
memory, calculate checksum,
StopRoutineByLocalID (0x32)
testing routines, etc
StopRoutineByAddress (0x39)
Î Control option is at the sub-function
RequestRoutineResultByLocalI
D (0x33)
RequestRoutineResultByAddre
ss (0x3A)
Î Controls routines, as erasing
memory, calculate checksum,
testing routines, etc

43 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Debreceni Egyetem - Informatikai Napok

Purpose of the Services


Î Diagnostic and Communication Management
Î Data Transmission
Î Stored Data Transmission
Î Input / Output Control
Î Remote Activation of Routine
Î Upload / Download
Î CARB / OBD / EOBD / KOBD

44 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

22
Debreceni Egyetem - Informatikai Napok

KWP2000 and UDS


RequestDownload (0x34)
Î The tester specifies an address and a length (not one byte), but no data
Î Specifies compressing methods
Î The ECU starts a downloading session
RequestUpload (0x35)
Î The same as RequestDownload, but initializes uploading session
TransferData (0x36)
Î Transfers the data bytes, with a help of sequence number, until the required
amount of data is reached
RequestTransferExit (0x37)
Î Terminates downloading / uploading

45 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

Questions?

46 GS-TC/ENC-Bp | 2008-03-27 | © Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede
Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.

23

You might also like