SERVICE MANUAL
CONTENTS: This document contains the instructions to set electronic board parameters via user interface for
following dishwashers:
EDITION: 01.2014
Valid for firmware versions: 0.23 and higher.
WARNING:
All the safety regulations and procedures to be followed by the Specialised Technician/Technical Assis-
tance performing electrical, mechanical or electronic maintenance operations are contained in the instruc-
tion manual supplied with the machine: refer to this document before operating. This applies for anyone
carrying out operations using these documents. The specialised technician must wear personal protection
equipment suitable for the work being performed (e.g. gloves, safety glasses and shoes, suitable clothing,
etc.) and use appropriate tools, equipment and auxiliary means.
INDEX
1 KEYBOARDS Pag. 4
1.1 DESCRIPTION OF CONTROL PANEL Pag. 4
1.2 SERVICE/ MAINTENANCE COMMANDS Pag. 4
2 MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS Pag. 5
2.1 DETERGENT DISPENSER ACTIVATION Pag. 5
2.2 RINSE AID DISPENSER ACTIVATION Pag. 5
3 RINSE PUMP MANUAL ACTIVATION Pag. 5
4 ACCESSING THE PARAMETERS MENU Pag. 5
5 USER PARAMETERS Pag. 8
5.1 DISPENSERS PARAMETERS - DETERGENT AND RINSE AID DOSAGE Pag. 8
5.1.1 Peristaltic tube fitting and replacement instructions Pag. 10
5.2 COUNTERS Pag. 12
6 FACTORY PARAMETERS Pag. 14
6.1 BOILER PARAMETERS Pag. 14
6.2 TANK PARAMETERS Pag. 16
6.3 CYCLE SETTING Pag. 17
6.3.1 Wash cycle diagram Pag. 18
6.3.2 Cycle 1 parameters Pag. 19
6.3.3 Cycle 2 parameters Pag. 19
6.3.4 Cycle 3 parameters Pag. 19
6.3.5 Drain/Cleaning cycle parameters Pag. 19
6.4 OTHER PARAMETERS Pag. 21
6.4.1 Dishwashing parameters Pag. 21
6.4.2 Read Only parameters Pag. 21
6.4.3 Communication and HACCP parameters Pag. 21
6.4.4 Configuration parameters Pag. 22
6.4.5 Delime cycle parameters (Delime) Pag. 22
6.4.6 Energy saving device parameters (ESD) Pag. 25
6.4.7 Water softener parameters Pag. 25
1 KEYBOARDS
A = On / Off
A B = Open hood
C = Close hood
D = “Tank temperature” indicator light
B
E = “Water tap” indicator light
C E F = “Boiler temperature” indicator light
G = Wash cycle 1
D F H = Wash cycle 2
I = Wash cycle 3
L = High Productivity or ETL-Sanitization
M = Drain / self-cleaning cycle
N = Delime cycle (this function can only be activated by a specialised
G H technician)
I L
M N
Fig. 1 Detergent Fig. 2 Rinse Aid Fig. 3 Rinse Pump Fig. 4 Accessing the
dispenser Manual Dispenser Manual Manual Activation (used parameters menu
Activation Activation to EMPTY BOILER)
When replacing detergents may be necessary activate the dispensers to fill hoses.
dEt
rAi
Use this function to empty the boiler (if the dishwasher is not to be used for a long time, for maintenance oper-
ation: ex. before replacing main board).
The parameters are divided into two families: user parameters and factory parameters.
In the family there are parameters for adjusting the detergent and rinse aid dispensers and the counters
(wash cycles, drain/cleaning cycles, etc. ).
In the family there are all parameters that determine dishwasher operation: boiler and tank working tem-
perature, duration of the phases of each cycle, etc.
To access the parameters menu, the unit must be in standby mode: switch on the unit and check that no
cycles are selected. In the programming phase it is advisable to keep the hood open to avoid starting a cycle
if the two buttons are not pressed together (see point 2 in the following example).
Example:
With reference to Table 1 ACCESSING THE PARAMETERS MENU assuming the boiler temperature parame-
ter is to be modified.
1. Switch the dishwasher off and then on again;
2. Enter the parameter mode by pressing and holding down the On/ff buttons (“A” - Par. 1.1 DESCRIPTION
OF CONTROL PANEL) and wash cycle 2 (“H” - 1.1 DESCRIPTION OF CONTROL PANEL) for approx. 5
sec. The display shows the message ;
3. Press the wash cycle 2 (“H” - Par. 1.1 DESCRIPTION OF CONTROL PANEL) button to go to the fam-
ily;
4. Press the button (“L” - 1.1 DESCRIPTION OF CONTROL PANEL) to access the boiler parameters
family;
5. Press the button (“L” - Par. 1.1 DESCRIPTION OF CONTROL PANEL) again to display the boiler tempera-
ture parameter ;
6. Press the button (“L” - Par. 1.1 DESCRIPTION OF CONTROL PANEL) again to display the boiler tempera-
ture parameter value;
7. Use wash cycle 1 (“G” - Par. 1.1 DESCRIPTION OF CONTROL PANEL) and wash cycle 2 (“H” - Par. 1.1
DESCRIPTION OF CONTROL PANEL) to modify the parameter value; use the wash cycle 1 button to
decrease the value and the wash cycle 2 button to increase it;
NOTE: If the tank LED is on, the parameter value corresponds to the factory-set value.
8. Press the button (“L” - Par. 1.1 DESCRIPTION OF CONTROL PANEL) to confirm the value and return to
the display of parameters.
NOTE: To exit the parameter mode and return to the display of the families, press wash cycle 3 (“I” - Par.
1.1 DESCRIPTION OF CONTROL PANEL).
Similarly it is possible to change the other values; afterwards, switch the machine off and then on again.
Default
55 11 76 2
- + - + - + - +
5 USER PARAMETERS
Initial Detergent Dosage (during filling tank) [g/l] 0 4,00 2,00
[s] 0 240 55
Initial Rinse Aid Dosage (starts when tank filled) [g/l] 0 1,00 0,12
[s] 0 180 11
Detergent Dosage During Cycle Execution (during wash phase) [g/l] 0 4,00 2,00
[s] 0 182 (*) 5
Rinse Aid Dosage During Cycle Execution (when refilling boiler) [g/l] 0 1,00 0,12
[s] 0 62 (*) 2
Example
Suppose there is connected an external detergent dispenser with a probe into the tank.
A typical setting could be:
• the dispenser is not activated during filling tank;
• the dispenser is supplied during washing phase and the probe automatically dose the right
detergent amount.
63°C USr
Dispensers parameters
diS
Default
Tube
Ruoller
Front box
3. Keep the tube in the seat in the housing and 4. Keep the tube in the seat in the housing and con-
continue turning the roller clockwise, being tinue turning the roller clockwise.
careful not to damage the tube.
5. Turn the roller a full 360°. 6. Make sure to fit the union in the special seat (deliv-
ery).
5.2 COUNTERS
This Parameter Family collects cycle counters and water consumption counters.
For water consumption counters a flow meter must be installed. See (calibration parameter) into
section (6.4 OTHER PARAMETERS).
Factory
Sym. Parameter Description Unit Min Max
Default
Performed cycles (partial counter is resettable by user via the “”
- - - -
parameter).
Counts m3 of water consumption (counter is NOT resettable by the - - - -
user). Works only if the flow meter is installed (integrated in the air gap
for machines with watersoftener).
Counts liters of water consumption (counter is NOT resettable by the [l] - - -
user). Works only if the flow meter is installed (integrated in the air gap
for machines with watersoftener).
Together with “” parameter (m3), This parameter gives the total
water consumption of the machine.
Litres counters [l] - - -
Counts the litres of water and is resettable by user (see parame-
ter below).
Works only if the flow meter is installed (integrated in the air gap for
machines with water softener).
Parameter to reset together counters: and - - - -
To reset put 1 this parameter, switch off and then on again: and
will show zero.
Drain/Cleaning cycles performed. - - - -
Similar to but counts Cleaning Cycles.
Delime cycles counter. - - - -
63°C USr
diS Cnt
CYC cyc
10 5
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank.
boi tub
Bt°C btH
Default
76 2
- + - +
Factory
Sym. Parameter Description Unit Min Max
Default
Tub Temperature: THRESHOLD [°C] 40 85 63
When tank temperature reaches this value, heater switch off.
Tub Temperature: HISTERESIS, (represent dead band). [°C] 2 30 5
Heater switch on if tank temperature is below: -
Tank Temperature: HIGH LIMIT. [°C] 0 95 85
When tank temperature reaches this value alarm appears.
Put 0 to disable alarm.
Tank Temperature: LOW LIMIT. [°C] 0 10 1
During tank warm-up, temperature must increase at least °C
otherwise warning appears.
Put 0 to disable warning.
Tank Filling Timeout. [min] 0 42 20
If filling time is longer than , alarm appears.
Put 0 to disable alarm.
Tank filling level. [mmH20] 50 200 100
Level (relevant to filling level ) used in the drain phase during the [mmH20] 2 20 8
cycle, that occurs after the wash phase.
Cicles to perform before a tank partial drain. - 0 50 0
If is , the function is disable. If the function is enabled, the
partial drain is performed in according with and
parameters (described below).
Tank partial drain level [mmH2O] 0 40 20
Increase the pause (between wash and rinse) when there is a tank [s] 0 16 6
partial drain.
Tank temperature in mode Thermal Label. [°C] 40 90 75
Tank parameters
boi tub
tt°C ttH
Default
63 5
- + - +
CYCLE TYME
IPA Ln Sh
PA
ri
dr
rPA
FP
dEt
rAi
KEY:
= initial pause
= wash [the duration is given by the sum of the two parameters (min) and (sec)].
= final pause
= rinse
= drain Attention: It does not necessarily correspond to activation of the drain
pump; activation of this pump is a function of the tank level.
= rinse pause
= detergent
= rinse aid
Ln1 Sh1
Default
0 33
- + - +
Factory
Sym. Parameter Description Unit Min Max
Default
Initial Pause before start washing (for ALL cycles) [s] 0 10 0
Celsius/Fahrenheit selection
= Celsius -
= Fahrenheit
Rinse Temperature Display.
Enable rinse temperature probe (if installed).
0 = during rinse phase the display shows boiler tempera- -
ture;
1 = during rinse phase the display shows rinse temperature.
Factory
Sym. Parameter Description Unit Min Max
Default
When message appears, the parameter value
becomes 3. - - - 0
After maintenance, to clear message, insert 0.
This parameter indicates the alarm code of an automatic
hood-type dishwasher. See the complete list of alarm
codes in par. 9.2 ALARMS THAT STOP THE DISH-
- - - 0
WASHER.
A read-only parameter and displays the modules installed
in the machine.
1 = Left LED bar installed - - -
2 = Right LED bar installed
4 = Water softener / automatic hood-type feeder
Factory
Sym. Parameter Description Unit Min Max
Default
Serial Device
0 = 8N1
1 = PC connection (DAAS 8E1) - 0 63 1
7 = HACCP network (ECAP 8E1+LK485) (LK485 board is
necessary)
Address.
This parameter specifies the address of the appliance into
the ‘HACCP_network’. - 0 255 1
Works only if ‘HACCP network’ is selected (see above
parameter).
Factory
Sym. Parameter Description Unit Min Max
Default
Dishwasher Model:
0 = HOOD TYPE - 0 3 0
Boiler type:
0 = ATMOSPHERIC BOILER
1 = PRESSURE BOILER (next versions) - 0 2 0
2 = EXTERNAL BOILER (next versions)
Default model (see Default tables):
1 = HOOD TYPE - 0 3 -
WARNING:
Only use wine vinegar and not other descaling substances. Descaling with the use of chemical substances
other than vinegar must only be done by a specialized technician.
1 N
4
D
3 N
5
2 DELIME
D
2. Access to the pump delime, in the machine, removing the front panel and lowering the control panel.
3. Disconnect the inlet pipe of pump “N”.
4. Connect the pipe “D” at the inlet connection of pump “N”.
5. Introduce the end part of delime pipe “D” in a container with acid (to ensure an adequate descaling, it is
recommended to use a solution of phosphoric acid between 30% to 50%).
WARNING:
Use appropriate safety measures during descaling operations with acid. Refer to safety data sheets
and to labels of the used product.
WARNING:
Make sure that the drain is properly installed according to the hydraulic circuit diagrams and installa-
tion diagrams as described in the instruction manual.
• Lift the hood and take out the rack and eventual dishes.
• In versions with supplementary filtering system (FS), remove the basket filter “1”, the flat filter “2”, the tank
filter “3” and the pump suction filter “4” (“A” - see below).
• In versions without supplementary filtering system (FS), remove the flat filter “1” and the pump suction filter
“2” (“B” - see below).
1
2
A 4 1
B 2
Press the button "N" (see Par. 1.1 DESCRIPTION OF CONTROL PANEL),for at least 5 seconds,
WARNING:
The delime cycle lasts about 1h 30 sec; during this phase the hood must not be opened and no other
command can be activated until completion of the cycle in progress. If the machine is turned off
during the delime cycle, at the next restart the cycle will resume exactly from where it was interrupted,
until its completion.
At the end of Delime cycle, the dishwasher sounds a series of beeps and "END" will flash on the display.
Refit the previously removed overflow.
If you have performed a delime cycle with acid, do the following operations:
6. Remove the pipe “D”.
6 N 8
7 N
D
9
DE
WARNING:
Make sure that at the end of descaling, the container with acid is removed.
7 DEFAULT VALUES
When receiving an electronic board (spare part) may be necessary to configure it in according to the machine
where has to be replaced
1. With the machine CODE enter into the following table and read the corresponding Prog. number
2. Follow the instructions reported into the corresponding Prog.XXX sheet (next pages).
3. With the machine CODE find the Layout number in Par. 8.3.1 Connectors layout.
LAYOUT 1
Not for
Middle Est,
Marine USA
versions
KEY
The display shows with door/hood closed Check door/hood micro/sensor
Check the user interface buttons (have they remained
No cycle starts
pressed? etc.)
Alarm codes for automatic hood type dishwasher (see paragraph 9.2.1 Alarm codes for auto-
matic hood type dishwashers).
Automatic Hood
DOOR_CLOSE
Hood is closed but the upper end limit switch (FC_UP) is active.
Hood is opening (starting from completely close position), but the lower end limit switch has not been
released.
During hood opening the lower end limit switch (FC_DW) has been activated.
Hood opening timeout: hood opening duration must be less than 18s (fixed value).
Check if the motor works properly.
Hood is open but the lower end limit switch is active (FC_DW).
Hood is closing (starting from completely open position) but the upper end limit switch has not been
released.
During hood closing the upper end limit switch (FC_UP) has been activated.
Hood closing timeout: hood closing duration must be less than 18s (fixed value).
Check if the motor works properly.
Combination not allowed:
upper end limit switch (FC_UP) and lower end limit switch(FC_DW) are both activated.
Overcurrent during hood opening phase.
WARNING:
Alarms , and lock the boiler temperature control.
Alarms , and lock the tank temperature control.
In the case of alarms and , the boiler waiting phase is not executed (the rinse may be performed
with cold water) and, during the initial warm-up and subsequent rinses ( > ), the boiler heating
phase is not executed.
In the case of an open probe error ( , e ), the displayed temperature is 10°C
In the case of a shorted probe error ( , e ) , the displayed temperature is 99°C.
CAUTION: IF THERE IS A MALFUNCTION ON RELAY RL1 AND THE BOILER HEATING ELE-
MENTS ARE FED BY MEANS OF A REMOTE CONTROL SWITCH, THE BOARD DOES NOT
HAVE TO BE REPLACED; JUST MOVE THE BOILER HEATING ELEMENT CONNECTOR TO
ONE OF THE TWO FREE POSITIONS ON THE BOARD.
CAUTION: WHEN ONE BRANCH OF THE HEATING ELEMENT DOES NOT WORK AND THE
OTHER TWO CONTINUE TO FUNCTION, ON REACHING THE SET TEMPERATURE VALUE,
ALARM 3 DISAPPEARS AND REAPPEARS IN THE SUBSEQUENT RINSE PHASE. THIS