Professional Documents
Culture Documents
Digital Panel Meters.133110152 PDF
Digital Panel Meters.133110152 PDF
Larsen & Toubro (L&T) is a technology-driven company that infuses engineering with
imagination. The Company offers a wide range of advanced solutions, in the fields of
Engineering, Construction, Electrical & Automation, Machinery and Information
Technology.
L&T Swtichgear, which forms part of the Electrical & Automation business, is India’s
largest manufacturer of low voltage switchgear, with the scale, sophistication and range
to meet global benchmarks. With over five decades of experience in this field, the
Company today enjoys a leadership position in the Indian market with growing presence
in International markets.
L&T manufactures and markets a comprehensive range of high quality electronic energy
meters and metering solutions for utilities, industries and commercial establishments.
L&T products are designed and developed in-house and conform to relevant Indian and
International standards. The products are manufactured at L&T’s Mysore Campus,
which is equipped with latest test facilities.
L&T through its emphasis on innovation, technology and quality is committed to support
its customers with accurate, reliable and easy to use electronic metering solutions.
CONTENT
VEGA 1
QUASAR 8
NOVA 12
ACRUX 14
GEMiNi 15
mi - ENERGY 17
VEGA 1
Ergonomic design
l
Standard size of 96 x 96 mm
l
Compact size of 96 x 96 mm
l
Standard size of 96 x 96 mm
l
Technical Specifications:
(Common for Single Function, VAF & Multi-Function Panel Meters)
Model VEGA
Single function : 90 to 300 V AC
Auxiliary voltage VAF : 90 to 300 V AC
Auxiliary Supply Multifunction : 80 to 300 V AC
Auxiliary burden < 4 VA
Frequency range 50 Hz ± 5%
For voltage, current and energy : Class 1.0
Class of accuracy For frequency : 0.2% of mid frequency
(Parameters as applicable to individual meters)
Measurement circuit burden < 0.2 VA per phase
Display Parameters
Single Function Digital Panel Meter
R Phase ü ü
Y Phase ü
Voltage B Phase ü
Line voltage ü
Average ü
R Phase ü ü
Y Phase ü
Current
B Phase ü
Average ü
Frequency ü
92
Connection Details
Single Function Meters
Single Phase Voltmeter Three Phase Voltmeter
L N R Y B N
1 11 1 11
2 12 2 12
3 13 3 13
4 14 4 14
Vega Vega
5 15 5 15
Panel Panel
6 16 6 16
Meter Meter
7 17 N 7 17 N
8 18 P 8 18 P
9 19 (AUX. SUPPLY) 9 19 (AUX. SUPPLY)
10 20 10 20
R N R Y B N
S1 S1
1 11 1 11
2 12 2 12
S2 S1
3 13 S2 3 13
4 14 4 14
Vega Vega S2 S1
5 15 5 15
Panel Panel
6 16 6 16
Meter Meter S2
7 17 N 7 17 N
8 18 P 8 18 P
9 19 (AUX. SUPPLY) 9 19 (AUX. SUPPLY)
10 20 10 20
Frequency Meter
L N
1 11
2 12
3 13
4 14
Vega
5 15
Panel
6 16
Meter
7 17 N
8 18 P
9 19 (AUX. SUPPLY)
10 20
VEGA 6
VAF Meters
1 11
2 12
3 13
4 14
N
5
Vega 15
S2
Aux
Supply 6 Panel 16 S1
P
7 Meter 17
S2
8 18 S1 S2
9 19
10 20
S1
R Y B N
Multifunction Meters
3 Phase 4 Wire 3 Phase 3 Wire
R YB N R Y B
S1 S2 S1 S2
S1 S2
S1 S2
S1 S2
S1 S2
SUPPLY)
D- 10 20 P
(AUX
SUPPLY)
D- 10 20 P
(AUX
D+ 9 19 N
D+ 9 19 N
RL1N 8 18
RL1N 8 18
RL1C 7 17
RL1C 7 17
Vega RL2N 6 Vega 16
RL2N 6 16
Model Model
RL2C 5 15
RL2C 5
A/B/C 15 A/B/C
4 14 4 14
3 13 3 13
2 12 2 12
1 11 1 11
Note:
lConnection of point 17 and 18 is not applicable for Model A
lD- and D+ are for communication using RS485
lRL1 and RL2 are relay connections
D+
RS232 to
RS485
Converter
D-
PC
Termination
Resistor
Ordering Information
Single Function Meters
Type of Meter 1 Phase / 3 Phase Cat. No.
1 Phase Meters WDS101FEV00
Voltmeter
3 Phase Meters WDS301FEV00
VAF Meters
Type Current Rating Cat. No.
Multifunction Meters
Type of Meter Current Rating Relay Cat. No.
Phase sequence
l
Harmonic measurement
l
Technical Specifications:
Model QUASAR
For power Class 1.0
IEC 62052-11, 62053-21/ IS 13779
Accuracy
For voltage ±10%
For current 0.5% of readout ± 2 digits
3 Ph 4 W- 415 V AC (-40% to +20%)
Voltage (Vn) 3 Ph 4 W- 110 V AC (-40% to +20%)
3 Ph 3 W- 110 V AC (-40% to +20%)
Current (In) 5 A or 1 A (Imax = 2In)
Starting Current 0.2% in (Class 1.0)
Frequency 50 Hz ±5%
< 8 VA in potential circuit
Load Characteristics
< 0.5 VA in current circuit
Electromagnetic Compatibility:
Electrical Fast Transient As Per IEC 62052-11, 62053-21, Test Level: 4 kV, 5k Hz
Surge Immunity As Per IEC 62052-11, 62053-21, Test Level: 4 kV
Influence of Short Time Over Currents 20 times Imax for 0.5 sec at rated frequency. As per IEC 62053-21
Case Material Plastic moulded protected to IP51- IEC 62052-11, 62053-21/IS 13779 (Class 1.0) (with panel)
Insulation Properties:
Insulation Resistance As per IEC 62052-11, 62053-21 / IS 13779 (Class 1.0)
AC voltage Test 2 kV AC RMS, 50 Hz for 1 minute as per IEC 62052-11
Impulse Voltage 6 kV, 1.2/50µ sec, as per IEC 62052-11
Voltage Dips and Interrupts As per IEC 61000-4-11
Display Backlit LCD, 10 mm height digits
Pulses/kWh Voltage/Current
2,500 / (external CT* PT) 3 Ph 4 W 415 V (L-L) / 5 A
Pulse Output 12,500 / (external CT* PT) 3 Ph 4 W 415 V (L-L) / 1 A
10,000 / (external CT* PT) 3 Ph 4 W / 3 W 110 V (L-L) / 5 A
50,000 / (external CT* PT) 3 Ph 4 W / 3 W 110 V (L-L) / 1 A
-10oC to 60oC for operation
Temperature
-20oC to 70oC for storage
Humidity 95% RH non condensing
Dimension 96 x 96 mm - depth 105 mm
Weight < 600 gms
QUASAR 9
Display Parameters:
Screen 1 --------------------- V, A, kW
Screen 2 --------------------- R-Y-B Voltages
Screen 3 --------------------- R-Y-B Currents
Screen 4 --------------------- R-Y-B kW
Screen 5 --------------------- R-Y-B kVAr
Screen 6 --------------------- R-Y-B kVA
Screen 7 --------------------- R-Y-B pF
Screen 8 --------------------- R-Y-B Volt angles
Screen 9 --------------------- R-Y-B Phase angles
Screen 10 --------------------- kW+kVAr+kVA
Screen 11 --------------------- Pd+pF+F
Screen 12 --------------------- kWh
Screen 13 --------------------- kVArh (L)
Screen 14 --------------------- kVArh (C)
Screen 15 --------------------- kVAh
Screen 16 --------------------- R ph. Voltage - Harmonics
Screen 17 --------------------- Y ph. Voltage - Harmonics
Screen 18 --------------------- B ph. Voltage - Harmonics
Screen 19 --------------------- R ph. Current - Harmonics
Screen 20 --------------------- Y ph. Current - Harmonics
Screen 21 --------------------- B ph. Current - Harmonics
112.5 96.0
5.6 97.5
69.0
90.0
96.0
QUASAR 10
R Y B R Y B N
A B b a 9 9
A B b a 10 10
A B b a 11 11
a 12 12
K k 1 K k 1
2 2
L I L I
K k 3 K k
Micro 3
Micro
4 Controller Controller
4
L I Circuit Circuit
L I
K k 5 K k 5
6
6
L I
L I
Tx+ 7
V (L-N) n In Tx+ 7
Tx- 8 V (L-N) n In
63.5 V 1A Tx- 8
Quasar
240 V 5A
63.5 V 1A Quasar
240 V 5A
R Y B R Y B
A a 9 9
B b
10 10
A a
B b 11 11
K k 1 K k 1
2 2
L l L I
Micro Micro
Controller Controller
Circuit Circuit
K k 5 K k 5
6 6
L I
Tx+ 7 Tx+ 7
V (L-L) n In Tx- 8 V (L-L) n In Tx- 8
110 V 1A Quasar 110 V 1A Quasar
5A 5A
QUASAR 11
Ordering Information
Accuracy Type Voltage Secondary Current RS485 Cat. No.
WI300FC1300
1A
ü WI300FC13RS
3 Ph, 4 W 240 V ( L-N)
WI300FC5300
5A
ü WI300FC53RS
WI301FC1300
1A
ü WI301FC13RS
Class 1 3 Ph, 3 W
WI301FC5300
5A
110 V ( L-L) ü WI301FC53RS
WI300FB1300
1A
ü WI300FB13RS
3 Ph, 4 W
WI300FB5300
5A
ü WI300FB53RS
WI300FC1200
1A
ü WI300FC12RS
3 Ph, 4 W 240 V ( L-N)
WI300FC5200
5A
ü WI300FC52RS
WI301FC1200
1A
ü WI301FC12RS
Class 0.5 3 Ph, 3 W
WI301FC5200
5A
ü WI301FC52RS
110 V ( L-L)
WI300FB1200
1A
ü WI300FB12RS
3 Ph, 4 W
WI300FB5200
5A
ü WI300FB52RS
NOVA 12
on display
Low CT/PT burden
l
Technical Specifications:
Model NOVA
Enclosure Engineering plastic complying to IP51
96 x 96 mm x 105 mm (HxWxD)
Dimension
Panel cutout: 92 x 92 mm
Connection 3P 4W
Display Backlit LCD
Type kWh Meter
Measurements kWh / kW / Frequency / Voltage / Current
Starting Current 0.2% of rated current (5 A)
Class of Accuracy Class 1.0
Current 5 A (rated), 10 A (max)
Voltage (P-N) 3 x 240 V (-30 % to +20 % of V Ref)
Frequency 50 Hz ± 5%
Auxiliary Supply 88 V to 300 V AC/DC
Weight 450 gm ± 5%
Weight with Packaging 610 gm ± 5%
Display Parameters:
Cumulative EB energy kWh
l R Phase voltage
l B Phase current
l
Average voltage
l Y Phase voltage
l R Phase active power
l
Average current
l B Phase voltage
l Y Phase active power
l
Total active power
l R Phase current
l B Phase active power
l
Frequency
l Y Phase current
l Phase sequence
l
Power factor
l
NOVA 13
5.6 97.5
69.0
90.0
Connection Details
R Y B N
L N
1 9
S1
2 10
S2
S1
3 11
S2
4 12
S1
AUX. SUPPLY
5 - 13
AC / DC
S2
6 + 14
ln = 1A; 5A
7 D+ 15
RS485
8 D- 16
Make the CT connections on terminals 1-2 (R-Ph), 3-4 (Y-Ph) and 5-6 (B-Ph)
l
Make the PT connections on the terminals 9 (R), 10 (Y), 11 (B) and 12 (N)
l
Connect the Auxiliary Supply (88 V to 300 V AC/DC) to the terminals 13 (-ve) and 14 (+ve) to power
l
ON the meter; it can be done by shorting one phase with auxiliary as shown in the above picture
Ordering Information
Cat. No. Description
WM30KFC3CRS 3 Ph 4 W 240 V 5 A with RS485 ( kWh meter with RS485 port ) - Nova
ACRUX 14
Technical Specifications:
Model ACRUX
Accuracy Class 1.0 as per IS 13779
Voltage Rating 240 V (3 Phase 4 Wire)
Current Rating (Ib) 5A&1A
Frequency 50 Hz ± 5%
Maximum Current 200% of Ib
Starting Current 0.4% of Ib
Operating Temperature 0 to 55oC
Display 6 Digit stepper motor counter
Enclosure Polycarbonate
Weight 500 g (approximate)
Mounting Flush mounting
Display Parameters:
Cumulative Energy kWh
NC
P1
P2
P3
P0
Acrux
3Phase 4 Wire
N
kWh
10k 1k 100 10 1 0.1
Panel Cutout
Y
104
96
M.F : 1 Class : 1
Manufactured by
K
K
L
L
k
k
I
M2
M3
L1
L2
L3
96
88 9
Ordering Information
Cat. No. Description
WM301FC1C10 3 Ph 4 W 240 V 1 A (kWh meter counter type) - Acrux
WM301FC3C10 3 Ph 4 W 240 V 5 A (kWh meter counter type) - Acrux
GEMiNi 15
Technical Specifications:
Model GEMiNi
Enclosure Engineering plastic complying to IP51
96 x 96 mm x 105 mm (HxWxD)
Dimension
Panel cutout: 92 x 92 mm
Connection 3P4W
Display Backlit LCD
Type kWh Meter
Measurements kWh / kW / Frequency / Voltage / Current
Starting Current 0.2% of rated current (5 A)
Class of Accuracy Class 1.0
Current 5 A (rated), 10 A (max)
Voltage (P-N) 3 x 240 V (-30 % to +20 % of V Ref)
Frequency 50 Hz ± 5%
Auxiliary Supply 88 V to 300 V AC/DC
DG Sensing Input 18 V-60 V DC/80 V-300 V AC
Weight 470 gm ± 5%
Weight with Packaging 630 gm ± 5%
Display Parameters:
Cumulative EB energy kWh
l Frequency
l Y Phase current
l
Cumulative gen. energy kWh
l R Phase voltage
l B Phase current
l
Average voltage
l Y Phase voltage
l R Phase active power
l
Average current
l B Phase voltage
l Y Phase active power
l
Total active power
l R Phase current
l B Phase active power
l
Phase sequence
l
GEMiNi 16
69.0
90.0
Connection Details
R Y B N L N
1 9
S1
2 10
S2
S1
3 11
4 S2 12
DG
S1
AUX. SUPPLY
5 13
AC/DC
S2
6 14
In
DG SENING
7 D+ 15
RS485
AC/DC
1A
5A
8 D- 16
Aux. Supply : 88 V to 300 V AC/DC
DG Sensing Input : 18 V-60 V DC / 80 V-300 V AC
Ordering Information
Cat. No. Description
mi-ENERGY
mi-ENERGY is L&T's DIN rail mounted meter. Available
in 3 phase and 1 phase models, these meters can be
mounted inside distribution boxes to monitor electric
consumption of identified loads, circuits and areas.
l LCD display
l Class 2 accuracy
l Displays day, week, month and push-to-push kWh
consumption
l Push Button for parameter scrolling
l Low starting current
l Reverse current indication*
l Compact size and easy mounting
* For 3 Phase Meter
Display Parameters
Parameters 3-Phase Meter 1-Phase Meter
Phase voltage ü ü
Phase current ü ü
Power factor ü
Instantaneous
Active power ü ü
Parameters
Reactive power ü
Apparent power ü
Frequency ü
Technical Specifications:
Type 6 digit LCD
Display
Height 6 mm (10 mm in case of 3 Phase meter)
Class of accuracy Class 2 as per IEC 62053-21
Measurement circuit burden <1 W, <8 VA
Rated Voltage 240 V
3 phase: 10-60 A
Current
1 phase: 5-30 A
Measuring Circuit
3 phase: 40 mA
Starting current
1 phase: 20 mA
Wiring Diagram
3-Phase 1-Phase
N N
B
Y P
R
M1 M0
M1 M2 M3 M0 1 Phase
Load
mi Energy 3 Phase mi Energy
Load
L1 L2 L3
L1
Dimensional Details
3-Phase 1-Phase
36
5
6 6.
125
83
88
83
All Dimensions in mm
Ordering Information
3 phase 4 wire 240 V 10-60 A W4DLD100600
1 phase 2 wire 240 V 5-30 A W2DLD050600
TESTING FACILITIES 20
L&T’s manufacturing facility at Mysore is equipped with the latest test equipment including environmental
test chambers, comprehensive EMI/EMC setups and high energy lightning surge test facilities. Here our
products are constantly tested for function, accuracy, insulation, response to climatic conditions, EMI/EMC
and mechanical requirements. Incoming inspection of electrical and mechanical components, field failure
analysis, calibration of in-house equipment, outgoing inspection and validation of meter software & base
computer software is done at the lab.
TEST SETUPS
l Dry Heat Chamber
l Rain Chamber
l Climatic Chamber
l Dust Chamber
l Electrostatic Discharge Simulator
l Electrical Fast Transient Simulator
l Lighting Surge Simulator
l Damped Oscillator Simulator
l Conducted Wave Simulator
l Vibration Shaker System
l AC Voltage Tester
l Glow Wire Test
l Insulation Resistance Tester
l Mechanical Shock Simulator
l Impulse Voltage Test
l Radio Interference Test
l Radiated Susceptibility Test
l Damp Heat Cyclic Test
l CT/PT Tester
l MMD Calibrator
l Magnetic Test
Electrical Standard Products (ESP) Branch Offices:
REGISTERED OFFICE AND Khairasol, Degaul Avenue EBG North Wing Office-Level 2
HEAD OFFICE Durgapur 713 212 Gate 7, Powai Campus
L&T House, Ballard Estate Tel: 2559848, 2559849, 2559844 Mumbai 400 072
P. O. Box 278 Fax: 0343-2553614 Tel: 022-67052874 / 2737 / 1156
Mumbai 400 001 e-mail: esp-dgp@LNTEBG.com Fax: 022-67051112
Tel: 022-67525656 e-mail: esp-bom@LNTEBG.com
Fax: 022-67525858 Milanpur Road, Bamuni Maidan
Website: www.Larsentoubro.com Guwahati 781 021 12, Shivaji Nagar
Tel: 0361-2550562 / 65 North Ambazari Road
ELECTRICAL STANDARD PRODUCTS (ESP) Fax: 0361-2551308 Nagpur 440 010
501, Sakar Complex I e-mail: hazrasudipto@LNTEBG.com Tel: 0712-2260012 / 3
Opp. Gandhigram Rly. Station Fax: 0712-2260020 / 30
Ashram Road II Floor, Vasantha Chambers e-mail: esp-nag@LNTEBG.com
Ahmedabad 380 009 5-10-173, Fateh Maidan Road
Tel: 079-66304006-11 Hyderabad 500 004 32, Shivaji Marg
Fax: 079-66304025 Tel: 040-67015052 P. O. Box 6223
e-mail: esp-ahm@LNTEBG.com Fax: 040-23296468 New Delhi 110 015
e-mail: esp-hyd@LNTEBG.com Tel: 011-41419514 / 5 / 6
38, Cubbon Road, P. O. Box 5098 Fax: 011-41419600
Bangalore 560 001 Monarch Building, 1st Floor e-mail: esp-del@LNTEBG.com
Tel: 080-25020100 / 25020324 D-236 & 237, Amrapali Marg
Fax: 080-25580525 Vaishali Nagar L&T House
e-mail: esp-blr@LNTEBG.com Jaipur 302 021 P. O. Box 119
Tel: 0141-4385914 to 18 191/1, Dhole Patil Road
131/1, Zone II Fax: 0141-4385925 Pune 411 001
Maharana Pratap Nagar e-mail: esp-jai@LNTEBG.com Tel: 020-26164048
Bhopal 462 011 Fax: 020-26164048/26164910
Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Akashdeep Plaza, 2nd Floor e-mail: esp-pnq@LNTEBG.com
Fax: 0755-3080502 P. O. Golmuri
e-mail: esp-bho@LNTEBG.com Jamshedpur 831 003 Crystal Tower, Plot No. 606/1
Jharkhand 4th Floor, G. E. Road
Plot No. 559, Annapurna Complex Tel: 0657-2312205 / 38 Telibandha
Lewis Road Fax: 0657-2341250 Raipur - 492 006
Bhubaneswar 751 014 e-mail: esp-jam@LNTEBG.com Tel: 0771-4283214
Tel: 0674-6451342, 2436696 e-mail: esp-raipur@LNTEBG.com
Fax: 0674-2537309 Skybright Bldg; M. G. Road
e-mail: esp-bbi@LNTEBG.com Ravipuram Junction, Ernakulam 3rd Floor
Kochi 682 016 Vishwakarma Chambers
SCO 32, Sector 26-D Tel: 0484-4409420 / 4 / 5 / 7 Majura Gate, Ring Road
Madhya Marg, P. O. Box 14 Fax: 0484-4409426 Surat 395 002
Chandigarh 160 019 e-mail: esp-cok@LNTEBG.com Tel: 0261-2473726
Tel: 0172-4646840, 4646853 Fax: 0261-2477078
Fax: 0172-4646802 3-B, Shakespeare Sarani e-mail: esp-sur@LNTEBG.com
e-mail: esp-chd@LNTEBG.com Kolkata 700 071
Tel: 033-44002572 / 3 / 4 Radhadaya Complex
L&T Construction Campus Fax: 033-22821025 / 7587 Old Padra Road
TC-1 Building, II Floor e-mail: esp-ccu@LNTEBG.com Near Charotar Society
Mount-Poonamallee Road Vadodara 390 007
Manapakkam A28, Indira Nagar, Faizabad Road Tel: 0265-6613610 / 1 / 2
Chennai 600 089 Lucknow 226 016 Fax: 0265-2336184
Tel: 044-2270 6800 Tel: 0522-4929905/04 e-mail: esp-bar@LNTEBG.com
Fax: 044-22706940 Fax: 0522-2311671
e-mail: esp-maa1@LNTEBG.com e-mail: esp-Lko@LNTEBG.com 48-8-16, Dwarakanagar
Visakhapatnam 530 016
67, Appuswamy Road No: 73, Karpaga Nagar, 8th Street Tel: 0891 670 1125 to 30
Post Bag 7156 K. Pudur Fax: 0891 670 1139
Opp. Nirmala College Madurai 625 007 e-mail: esp-viz@LNTEBG.com
Coimbatore 641 045 Tel: 0452-2537404, 2521068
Tel: 0422-2588120 / 1 / 5 Fax: 0452-2537552
Fax: 0422-2588148 e-mail: esp-mdu@LNTEBG.com
e-mail: esp-cbe@LNTEBG.com
Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.
SP 50539 R1 150313