1.Maintenance Margin:
R40 cannot perform brings: SPA5300 no‐
output or unstable Volume or SPK output with
noice
2. Tools for repair: electric iron ,screw driver
and multimeter
Vr
GND
Vout
4.Steps for repair:
c.If the test result shows Vout<8.5V and Vr>19V,then there is R40
failure,remove the R40by using the electic iron,and change a new one
(make sure there is a seccssful welding),as
R40
If the R40 is operating normally, then there should be another problem for
the broken product, pleace send it back to Philips for anaylsis.
4.Steps for repair:
d.Check the Vout again after repair, if Vout>8.5V,then the problem is
repaired;if not, then there should be another problem for the broken
product, pleace send it back to Philips for anaylsis
e.Reset the product,and do a sound test. If the sound without nioce, or
the volume is stable, then the product is repaired. Repackage the product
and send back to the customer.
If the problem is still here, then there should be another problem for the
broken product, pleace send it back to Philips for anaylsis.