Boundary Conditions:
L = 2.1 m
d = 495 mm
qe = 162.6895 Kpa
Dimension of Footing
Depth of Footing
Vu = 232.5965 Kpa
0.232596 Mpa
d = 295 mm
d = 370 mm
Use:
d = 370 mm
Mu = 131.88 KN-m
Ru = 0.59 Mpa
ρ = 0.00220
ρmin = 0.005091
Use: ρ = 0.00509
As = 3390.545 sq.mm