Designer : QUIDATO, ANGELBERT F.

MANLANGIT, CHRISTIAN LOUIE S.


Project: FOUR STOREY RESIDENTIAL HOUSE
Location: KARUHATAN, VALENZUELA CITY, PHILIPPINES
DESIGN CRITERIA
Reference Code:
NATIONAL STRUCTURAL CODE OF THE PHIL. VOL. I – 2015 ed.
LOADS:
I. DEAD LOADS (Table 204-2)
a. Roof
Deck Metal 20 Gage ------------- 0.12 kPa
b. WALLS
Exterior Wall
6” CHB ------------------------ 3.45kPa
Interion Wall
(CHB plastered) --------------------1.72 kPa
c. Water Proofing ------------------ 0.05 kPa
d. Mechanical and Electrical Fixtures ----------------- 0.20 kPa
e. Floor finishes
Ceramic or quary tiles (20mm) on 13mm mortar bed ---------------- 0.77 kPa
Partition loads ---------- 1.00 kPa
f. Ceiling
Plaster on Wood lath --------------- 0.38 kPa
II. LIVE LOADS (4 storey)
a. Residential (4 storey)
Basic Floor Area (Residential) ----------------- 1.90 kPa
Exterior Balconies -------------- 2.8 kPa
Roof Deck --------------- 1.9 kPa
Storage ---------------- 1.9 kPa
III. EARTHQUAKE LOADS
Seismic Zone 4: Z ------ 0.4 (Figure 208-2A)
Seismic Source Type -------- A (Table 208-6)
Soil Profile Type ----------- Sc
Near Source Factor
Na -------------- 1.0
Nv -------------- 1.0
Seismic Coefficient:
Ca -------------- 0.4xNa= 0.4
Cv -------------- 0.56xNv= 0.56