You are on page 1of 11

Model / Type Perseus™ A500

Country of Origin Germany


Factory of Origin Luebeck - Germany
OEM NO
Product Certification EN 60601-1
Product Registration IEC 60601-1
FDA Clearance NO
CE Mark Yes
IEC Compliance IEC 60601-1-1
Locally Content No
Where Marketed Worldwide
Green Features Yes
Other Specification Auto On,Flush & Dry,ID Acessories, HLM, Agent Comsuption
UMDNS Code 10-134/37710
Function Anestesia Workstation
Supplier Footnote NA
Model Footnote NA
Data Footnote NA
Other Information NA
SOLE AGENT/ DISTRIBUTOR
CERTIFICATE OF PRODUCTION
CERTIFICATE OF DISTRIBUTION (PAK)
ADDRESS

PHONE/ FAX. / E-MAIL

NAME OF PRODUCT
BRAND / MANUFACTURER
MODEL / TYPE
COUNTRY OF ORIGIN
FACTORY OF ORIGIN
OUTSOURCE EXTERNAL MANUFACTURE (OEM)
PRODUCT'S REGISTRATION (AKL/AKD)
PRODUCT'S CERTIFICATION
FDA Clearance
CE Mark (MDD)
Certificate ....
Certificate ....
Locally Content (Tingkat Komponen Dalam Negeri)
WHERE MARKETED
REFERENCE OF TECHNICAL
PATIENT TYPE
ACUITY LEVEL

CONFIGURATION
PIPELINE GAS INLETS
GAS CYLINDER YOKES

VAPORIZERS, AGENTS

Type
Number
Interlock
SUCTION SYSTEM
O2 FAIL-SAFE

HYPOXIC MIXTURE FAIL-SAFE

AUTOMATIC VENTILATOR
Bellows, size
Type
Primary controls

Ventilation modes

Tidal volume
Minute volume
Frequency, bpm
Inspiratory flow, L/min
IE ratio
Inspiratory pause
Pressure limit, cm H2O
PEEP, cm H2O
Other controls
System checks

SCAVENGING SYSTEM

AUTO RECORD KEEPER

ANESTHESIA DATA MANAGEMENT

MONITORS
Airway pressure
Where measured
High-pressure alarm
Subatmospheric pressure alarm

Continuing pressure alarm


Low pressure/apnea
Other pressure alarms

Expiratory volume/flow
Type of sensor
Where measured
Rate alarm

Apnea alarm
Reverse-flow alarm
High/low minute volume

High/low flow
Other expiratory alarms
O2 concentration
Type of sensor
Response time, sec
CO2 concentration
Apnea alarm

N2O

Agent monitors

Type of agents
Auto ID

Agent concentration alarm

ECG
Heart rate
ST segment
Noninvasive BP
Invasive BP
Temperature
Pulse oximeter
Other monitors
Other features

DISPLAYS
Number
Type
Integrated
Interface with others
USER INTERFACE

DATA EXPORT

PRIORITIZED ALARMS

MRI CONDITIONAL
Magnetic field strength, T
Gauss line restriction, G
PHYSICAL FEATURES
Dimension (H x W x D), cm (in)
Weight, kg (lb)
Shelves, cm (in) ( W x D )
Drawers, cm (in)
Writing shelf, cm (in)
POWER REQUIRED, VAC
Auxiliary outlets
BACKUP BATTERY
Type
Use per charge, hr
GREEN FEATURES

OTHER SPECIFICATIONS

UMDNS CODE(S)
LAST UPDATED
Supplier Footnotes
Model Footnotes
Data Footnotes
OTHER INFORMATIONS *)
*) Example : Delivery Time, Capacity of Production, Price,
Commitment of Maintenance, Warranty, Discontinue/Life
: PT. Draeger Medical Indonesia
: ……………………………………
: HK.07.Alkes /IV/ 055/ AK/ 2014
: Menara Standard Chartered Lt. 30. Jl. Prof. Dr. Satrio no. 164.
Jakarta
: 021 7664105 / 021 75915739

PRODUCT
Draeger
Perseus™ A500
Germany
Germany
No
Yes
EN 60601- 1
No
YES
Yes
EN 60601-2-13.

Worldwide

Neonatus, Paediatrix ,Adult


Intelligent tool for control low flow,Fresh Gas Deficit ( Econometer
trend),Prediction of FIO2 Intelligent tool for Fresh Gas Eficiency for the
last 30 minute.

Operation of range 2,7 to 6,9 bar ( N2O,Air ,O2 )


Pin Index connection

Vapor prediction for next 20 minute


Illumination of vaporizer setting and filling level.
Support of vaporizer control by different illuminations for “off” ,“on” and
alarms.
Dedicated alarm for agent below minimum filling level.
Automatic prevention of the dosage by more than one vaporizer at the
same time without user interaction (other vaporizers blocked).
Sevoflurane, Isoflurane , Desflurane
2
Yes
Optional : Bronchial aspirator ( Air Ejector with Vacum drive )
Automatic switch over Air at constant Fresh Gas Flow and disabled
selection of carrier gas N2O

Manual ventilation possible at least with freshgas O2 delivery and


dosage of volate agents in case of system failure / system off

No
Ventilator with turbine principle
Electronically controlled and electrically driven ventilator (no driving
gas consumption).

Manual/Spontaneus, VCV ( Volume Control Ventilation),


PCV( Pressure Control Ventilation ),Pressure Support,SIMV.
AutoFlow,Manual Spontanesus with CPAP/PEEP .
APRV( Airway Pressure Release Ventilation).( Optional )
Ventilation and fresh gas flow can be paused during operation .

VCV 20 - 2000ml .PCV 4 - 2000 ml


0 - 40 ml
3 - 100 l/Min
0 to 180 l/min
1:50 to 50:1
20 to 60 [%].
PEEP +5 to 80 hPa (cmH2O);
Off, 2 to 35 hPa / mbar / cmH2O
PLOW APRV = Off, 2 to 35 hPa (cmH2O);P high: Plow +1 to 80 hPa
System Test ( Fully autometecly Dailly) ,Breathing syst. Test( after
change Flow sensor & Breathing System, Leakage test (After filling the
CO2 absorber,Leakage assistant.)

Integrated volume-buffered anaesthetic gas scavenging conforming to


EN 740.
Anesthetic exhaust hose for connecting the scavenging system to the
central ejector system

Data can be exchanged across an IT network by using hard-wired and


wireless technologies. An IT network can be any data interface (e.g.,
RS232,LAN, USB, printer interface)

Using Medibus Protocol via RS232.

Peak ,Pmean ,Pplat ,PEEP ,Real-time pressure wave, and PV loops


Piezo resistive
Breathing hoses are blocked or or the tube is kinked,
Fresh-gas flow is insufficient,breathing bag is blocked orpositioned
incorrectly.

Airway pressure has been continuously high.


No breathing or ventilation
Leakage or disconnection

Spirolog/ Spirolife ( ID Acessories)


: hot-wire anemometry
Fresh-gas flow is insufficient,breathing bag is blocked orpositioned
incorrectly
No breathing or ventilation
The breathing hoses are blocked or leaking
A significant minute volume was measured during cardiac bypass mode.

Breathing bag hose is too long/thin.


Apnea (no pressure),Apnea Ventilation,Apnea (no CO2)
21 to 100 Vol% (carrier gas Air);25 to 100 Vol% (carrier gas N2O)
Paragmanetic no need change ( long life time )
15 sec
300 to 1000 ppm
at the latest after 65 seconds for the Pause, Manual / Spontaneous and
Ext.
FG outlet modes

Measuring range: 0 to 100 [Vol%]

Isoflurane (I): 0 to 8.5 [Vol%],- Sevoflurane (S): 0 to 10 [Vol%]


Desflurane (D): 0 to 20 [Vol%]
Isoflurane, Desflurane, Sevoflurane
Automatic identification and measurements, of two volatile anesthetic
agents in gas mixtures.
Age corrected MAC calculation which takes anesthesia gases and nitrous
oxide into consideration
Inspiratory anesthetic gas,concentration has exceeded,the upper alarm
limit.
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Econometer trend , FIO2, Agent Consumption, MAC
ID Acessories, wash in, wash out ,HLM, Include Gas Monitoring,Auto On
& Dry ,
Screen color 15'3 inc
3 screen
Trend screen , Data Screen ,Standar screen
Metabolic Monitoring & Consumption calculation
Patien Monitor, Pendant ,Acessories.
Graphical User Interface (System Screen),Alarms for Ventilation
Monitoring
Data, waveforms, trends and loops display,Alarms General
Alarms for Breathing Gas Monitoring

The USB flash drive is connected to the USB interface

Audible and Visual with Alarm classification ( warning ,caution,


Advisory )

Not used in the MRI room


148 cm x 115 cm x 79 cm (58.3 in x 45,2 in x 31.1 in)
150 kg (335 lbs), basic equipment
33x23 cm
32x31x9 cm
93x52 cm
100–127 V~ 50/60 Hz or 200–240 V~ 50/60 Hz
4 x country specific (w isolation transformer) or 4 x IEC
maksimal 150 minute
Lead-gel battery,Sealed, maintenance-free
8 hours
Yes (Minimal Flow , Turbine Ventilator , AGGS ,Pause ,Econometer )

Include Acessories ( Breathing bag 0,5 L & 2 L, Hose Adult Reusable ,


Acessories
Paedistrix,TestLung, Draegersorb,Mask Reus no 2&3&4,Jacksoon Reece,
Bacterial Filter
10 - 134/37710
Oct-14
No
No.
No.
No
2,5 - 3 months
Price IDR. 1,316,867,850 (harga sudah termasuk Pajak)
Update Price 24-Oct-14
Warranty 1 Year
Delivery Time 2,5 - 3 Months after the PO Received
Training Included with purchase YES (Application Training up to 5 times)
Remote Diagnostics YES
Year first Sold 2014
Number Sold 1
Fiscal Year