Professional Documents
Culture Documents
PROVIDING
VERSION : 2011 R1
NATIONS WITH
CABLES
The contents of the pages of this catalogue are the copyrights of SAMA KEBEL SDN
BHD and all rights are reserved. All other intellectual property rights, including trade
marks, shall remain with SAMA KEBEL SDN BHD. The copying, publishing,
transmission to third parties or incorporation into any other work of part or all of the
material available in this catalogue in any form is prohibited SAVED FOR your
personal internal use. The terms and conditions apply to your use and your use of this
catalogue indicates your acceptance of the terms and conditions of this catalogue. If
you do not agree to the terms and conditions you must not use this catalogue. All
information provided in this catalogue (including but not limited to charts and
diagrams) is for illustration and reference purpose only and is believed to be correct at
the time of the last update to the relevant page. However, SAMA KEBEL SDN BHD
makes no warranties, express or implied, as to its accuracy, and accepts no liability
relating to its use. In the interests of continuous product improvement, SAMA
KEBEL SDN BHD reserves the right to alter specifications or materials as
appropriate. Purchasers are advised to refer to their consultants prior to making
purchases in order to determine the suitability of individual products for specific
applications.
Content Page
5 Flexible Cords F1 - F6
O
OU RC
UR CO
OMMP
PAAN
NYY
SAMA KEBEL SDN BHD (Company No. 221017-H) is inaugurated on the 17 July
1991 under the Companies Act, 1965 as a private limited company. With the aim of
building for the future, SAMA KEBEL has built itself a sterling reputation specialising
in the manufacturing of wires and cables up to 1,000V ( low voltage range ). As a
Malaysian company, SAMA KEBEL has naturally aspired to use materials of
Malaysian origin and local personnel.
T
TH EL
HE LO
OCCA
ATTIIO
ONN
SAMA KEBEL is most strategically situated in the Rawang Perdana Industrial Estate,
state of Selangor Darul Ehsan, a mere 25 kilometers from the capital city of Malaysia,
Kuala Lumpur, making our factory premises link by modern expressways to market
centers and ports around the country.
O
OU RP
UR PR
ROOD
DUUC
CTTS
S
The core business of SAMA KEBEL is primarily focused on the manufacturing of low
voltage copper wires & cables ( up to 1,000V ) including:
1
SAMA KEBEL SDN BHD (Company No. 221017-H)
Company Profile
O
OU RS
UR SEER
RVVIIC
CEES
S
Our services include manufacturing tailor-made cables to suit clients’ specifications
upon request to suit variety of system and installation requirements, including but not
limited to adhering to clients’ specific cable construction such as multi-pair, multi-
core, armoured and stranded versions, using RoHS compliance materials and special
sheathing materials such as termite protection, rodent protection, ultra-violet
protection, flame retardant etc. The cable sheath colour can also be customised.
IIN
N--H
HOOU
US ER
SE REESSEEA
ARRC
CHHA
AN DD
ND DEEV
VEEL
LOOP
PMME
ENNT
T
Apart from the above, SAMA KEBEL has invested in fire testing equipment and has
the capabilities to conduct its research and development activities in-house for flame
retardant (such as IEC 60332-3 test methods) and fire resistant wires & cables (such
as BS 6387 Cat. C, W & Z test methods). The ongoing R & D activities of SAMA
KEBEL may include the development of higher flame retardant wires & cables and
fire resistant wires & cables with better flexibility.
With products and services ranging from power cables, control cables,
instrumentation cables, telephone cables and fire resistant cables, the overall strategy
of SAMA KEBEL is to build businesses around a focus technology core in order to
obtain maximum leverage of its core competencies. One of the strengths of SAMA
KEBEL is its investment in R & D activities which allows the company to produce
environmental friendly wires & cables ( such as using unleaded PVC compounds and
LSHF compounds ) and also enhanced fire performance wires & cables, which in turn
enable SAMA KEBEL to extend its market share in the region.
C
COOU
UNNT
TRRIIE
ESSE
EXXP
POOR
RTTE
EDD
Up to 31 May 2011, SAMA KEBEL had exported its wires & cables directly to the
following countries:
2
SAMA KEBEL SDN BHD (Company No. 221017-H)
Company Profile
P
PRRO
OJJE
ECCT
TSSS
SUUP
PPPL
LIIE
EDDR
REEFFEER
REEN
NCCE
E
Our wires & cables are supplied to the followings projects through our wholesaler: -
• Malaysia
Lynas Advanced Material Project Gebeng; Kemanman Substation in Kuantan;
Kukup Substation Johor; Tudan Substation Miri; Project KTM (OEM); HICOM;
Kuala Lumpur International Airport (KLIA); LRT; Stadium Batu Kawan Pulau
Pinang; Kuala Lumpur City Center (KLCC); Putrajaya; Bukit Jalil; Cyberjaya
Dengkil; Formula 1 Sepang; Kompleks Sukan Kuala Selangor; Jelantut Palm Oil
Mill Pahang; Kulai Indahpura Johor etc.
• Hong Kong
Hong Kong Airport.
• Myanmar
Myanmar International Airport.
• Philippines
Rapu Rapu Mines Project; Subic Shipyard; Consolidated Industrial Gases Inc.
(CIGI); JGC Philippines
• Qatar
RAS Gas Limited; QATAR Petrochemical Company Ltd.
• Republic of Maldives
Maldives International Airport; Wataniya Resort; IGMH Hospital; Sonevagigili
Residential Villa Project; State Electricity Board
• Singapore
Shell Eastern Petroleum (Pte) Ltd Pulau Bukom
• Thailand
Petroluem Authority of Thailand; EGAT Plc Power Plant (Electricity Generating
Authority of Thailand)
• Vietnam
Dung Quat Oil Refinery
3
SAMA KEBEL SDN BHD (Company No. 221017-H)
Company Profile
Q
QUUA
ALLIIT
TYYA
ASSSSU
URRA
ANNC
CEE
SAMA KEBEL is an ISO 9002 accredited company with SIRIM (Standard Institute
and Research in Malaysia) and Suruhanjaya Tenaga approval.
The number one aim of SAMA KEBEL is to be a leader in providing quality and
reliability to our customers. Our policies include working towards total customers’
satisfaction with competitive price, prompt delivery and quality product. SAMA
KEBEL updates its employees on the latest developments in the industry as well as
increases their know-how by sending them to various courses throughout the year as
and when need arises in order to provide better products and services to its customers.
SAMA KEBEL has always committed to ensure that its high standards are adhered to
at every stage of the manufacturing process. An in-house team of skilled technicians
and engineers conducting constant stringent quality control checks are testament to
this pledge. In line with the company’s expansion plan, SAMA KEBEL will continue
to employ qualified staff to support the level of its business and operations.
T
TH EF
HE FU
UTTU
URRE
E
Aim for the excellent, SAMA KEBEL is not content to sit on its laurels. SAMA KEBEL
constantly upgrades its manufacturing equipment to the latest and most advance
technologies, increases its efficiencies, improves its research and development
capabilities for new products and materials, and establishes highest market reputation.
We are making plans to expand our product range to a wider array of power cables
and instrumentation cables. We are convinced that with our experience and dedicated
workforce, we will have the impetus to be at the forefront of the Malaysian cable
industry.
4
PVC-INSULATED
POWER CABLE
SAMA KEBEL SDN BHD
Application
Power cables for electricity supply are installed in open air, underground, in cable
ducts, outdoor and indoors, power stations, for industry and distribution boards as well
as in subscriber networks where mechanical damages are not to be expected. The
cables are suitable for continuous operation at a maximum conductor temperature of
70oC.
A1
PVC-INSULATED POWER CABLE
600/1000V, PVC Insulated, PVC Sheathed Unarmoured Cables
A2
PVC-INSULATED POWER CABLE
600/1000V, PVC Insulated, PVC Sheathed Unarmoured Cables
A3
PVC-INSULATED POWER CABLE
600/1000V, PVC Insulated, PVC Sheathed Armoured Cables
Application
Power cables for electricity supply are installed in open air, underground, in cable
ducts, outdoor and indoors, power stations, for industry and distribution boards as well
as in subscriber networks where there is a risk of mechanical damage. The cables are
suitable for continuous operation at a maximum conductor temperature of 70 oC.
A4
PVC-INSULATED POWER CABLE
600/1000V, PVC Insulated, PVC Sheathed Armoured Cables
Electrical Characteristics
Nominal Number Nominal
No. Thickness Thickness Thickness Approx Approx Cond. Insulation Short
Cross- and Armour
of of of of Overall Net Resistance Resistance Circuit
Sectional Diameter of Wire
Cores Insulation Bedding Sheath Diameter Weight Max. at Min. at Current
Area Wires Diameter
20oC 20oC for 1 sec.
no mm2 no/mm mm mm mm mm mm kg/km /km M /km kA
70 19/2.14 1.4 0.8 1.25 1.6 21.1 1090 0.268 5 10.00
95 19/2.52 1.6 0.8 1.25 1.6 23.4 1410 0.193 5 13.50
120 37/2.03 1.6 1.0 1.6 1.7 26.3 1790 0.153 5 17.10
150 37/2.25 1.8 1.0 1.6 1.7 28.3 2110 0.124 5 21.40
185 37/2.52 2.0 1.0 1.6 1.8 30.8 2560 0.0991 5 26.40
1
240 61/2.25 2.2 1.0 1.6 1.9 34.1 3260 0.0754 5 34.30
300 61/2.52 2.4 1.0 1.6 1.9 37.0 3970 0.0601 5 42.70
400 61/2.85 2.6 1.2 2.0 2.1 42.0 5100 0.0470 5 57.20
500 61/3.20 2.8 1.2 2.0 2.1 45.6 6230 0.0366 5 71.50
630 127/2.52 2.8 1.2 2.0 2.2 49.7 7720 0.0283 5 70.00
1.5 7/0.53 0.6 0.8 0.9 1.4 12.3 290 12.1 10 0.17
2.5 7/0.67 0.7 0.8 0.9 1.4 13.6 350 7.41 9 0.29
4 7/0.85 0.8 0.8 0.9 1.4 15.1 435 4.61 8 0.46
6 7/1.04 0.8 0.8 0.9 1.5 16.5 520 3.08 7 0.69
10 7/1.35 1.0 0.8 1.25 1.6 20.1 850 1.83 7 1.15
16 7/1.70 1.0 0.8 1.25 1.6 21.9 1030 1.15 6 1.85
25 7/2.14 1.2 1.0 1.6 1.7 26.7 1640 0.727 5 2.9
35 19/1.53 1.2 1.0 1.6 1.8 24.9 1735 0.524 5 4.0
2 50 19/1.78 1.4 1.0 1.6 1.9 27.8 2080 0.384 5 5.8
70 19/2.14 1.4 1.0 1.6 1.9 30.4 2610 0.268 5 8.1
95 19/2.52 1.6 1.2 2.0 2.1 35.5 3650 0.193 5 11.0
120 37/2.03 1.6 1.2 2.0 2.2 38.0 4280 0.153 5 13.9
150 37/2.25 1.8 1.2 2.0 2.3 41.3 5050 0.124 5 17.3
185 37/2.52 2.0 1.4 2.5 2.4 46.4 6530 0.0991 5 21.4
240 61/2.25 2.2 1.4 2.5 2.5 51.2 8150 0.0754 5 27.7
300 61/2.52 2.4 1.6 2.5 2.7 56.4 9850 0.0601 5 34.6
400 61/2.85 2.6 1.6 2.5 2.9 61.9 11950 0.047 5 46.2
1.5 7/0.53 0.6 0.8 0.9 1.4 13.0 330 12.1 10 0.17
2.5 7/0.67 0.7 0.8 0.9 1.4 14.1 420 7.41 9 0.29
4 7/0.85 0.8 0.8 0.9 1.4 15..8 520 4.61 8 0.46
6 7/1.04 0.8 0.8 1.25 1.5 18.0 720 3.08 7 0.69
10 7/1.35 1.0 0.8 1.25 1.6 21.2 990 1.83 7 1.15
16 7/1.70 1.0 0.8 1.25 1.6 23.1 1240 1.15 6 1.85
25 7/2.14 1.2 1.0 1.6 1.7 28.2 1900 0.727 5 2.9
35 19/1.53 1.2 1.0 1.6 1.8 27.3 2220 0.524 5 4.0
3 50 19/1.78 1.4 1.0 1.6 1.9 30.5 2730 0.384 5 5.8
70 19/2.14 1.4 1.2 2.0 2.0 35.0 3820 0.268 5 8.1
95 19/2.52 1.6 1.2 2.0 2.1 39.3 4850 0.193 5 11.0
120 37/2.03 1.6 1.2 2.0 2.2 42.2 5780 0.153 5 13.9
150 37/2.25 1.8 1.4 2.5 2.4 47.5 7330 0.124 5 17.3
185 37/2.52 2.0 1.4 2.5 2.5 51.9 8830 0.0991 5 21.4
240 61/2.25 2.2 1.6 2.5 2.6 57.8 11140 0.0754 5 27.7
300 61/2.52 2.4 1.6 2.5 2.8 63.2 13500 0.0601 5 34.6
400 61/2.85 2.6 1.6 2.5 3.0 69.6 16750 0.047 5 46.2
Circular or compacted circular stranded conductors. (Single core: All; 2 Core: Up to and including 25mm2; 3 Core: Up to and including 25mm2).
Sector shaped stranded conductors. (2 Core: 35mm2 and above; 3 Core: 35mm2 and above)
A5
PVC-INSULATED POWER CABLE
600/1000V, PVC Insulated, PVC Sheathed Armoured Cables
Electrical Characteristics
Nominal Number Nominal
No. Thickness Thickness Thickness Approx Approx Cond. Insulation Short
Cross- and Armour
of of of of Overall Net Resistance Resistance Circuit
Sectional Diameter of Wire
Cores Insulation Bedding Sheath Diameter Weight Max. at Min. at Current
Area Wires Diameter
20oC 20oC for 1 sec.
no mm2 no/mm mm mm mm mm mm kg/km /km M /km kA
1.5 7/0.53 0.6 0.8 0.9 1.4 13.8 380 12.1 10 0.17
2.5 7/0.67 0.7 0.8 0.9 1.4 15.0 465 7.41 9 0.29
4 7/0.85 0.8 0.8 1.25 1.5 17.8 710 4.61 8 0.46
6 7/1.04 0.8 0.8 1.25 1.5 19.2 835 3.08 7 0.69
10 7/1.35 1.0 0.8 1.25 1.6 22.8 1175 1.83 7 1.15
16 7/1.70 1.0 1.0 1.6 1.7 26.3 1730 1.15 6 1.85
25 7/2.14 1.2 1.0 1.6 1.8 30.7 2350 0.727 5 2.9
35 19/1.53 1.2 1.0 1.6 1.9 30.5 2710 0.524 5 4.0
4
50 19/1.78 1.4 1.2 2.0 2.0 35.4 3850 0.384 5 5.8
70 19/2.14 1.4 1.2 2.0 2.1 39.2 4910 0.268 5 8.1
95 19/2.52 1.6 1.2 2.0 2.2 44.3 6370 0.193 5 11.0
120 37/2.03 1.6 1.4 2.5 2.4 49.3 8075 0.153 5 13.9
150 37/2.25 1.8 1.4 2.5 2.5 53.6 9540 0.124 5 17.3
185 37/2.52 2.0 1.6 2.5 2.6 59.0 11640 0.0991 5 21.4
240 61/2.25 2.2 1.6 2.5 2.8 65.7 14650 0.0754 5 27.7
300 61/2.52 2.4 1.6 2.5 3.0 72.0 17730 0.0601 5 34.6
5 0.8 0.9 1.4 14.3 420
7 0.8 0.9 1.4 15.2 495
10 0.8 1.25 1.5 19.0 770
12 0.8 1.25 1.5 19.4 830
1.5 7/0.53 0.6 12.1 10 0.17
19 0.8 1.25 1.6 22.2 1090
27 1.0 1.6 1.7 26.7 1600
37 1.0 1.6 1.8 29.2 1950
48 1.0 1.6 1.9 32.9 2360
5 0.8 0.9 1.5 16.3 550
7 0.8 1.25 1.5 18.0 750
10 0.8 1.25 1.6 21.9 1000
12 0.8 1.25 1.6 22.4 1090
2.5 7/0.67 0.7 7.41 9 0.29
19 1.0 1.6 1.7 26.6 1650
27 1.0 1.6 1.8 30.7 2100
37 1.0 1.6 1.9 34.0 2610
48 1.2 2.0 2.1 39.5 3550
5 0.8 1.25 1.5 19.0 810
7 0.8 1.25 1.6 20.5 960
10 1.0 1.6 1.7 26.1 1500
4 7/0.85 0.8 4.61 8 0.46
12 1.0 1.6 1.7 26.8 1620
19 1.0 1.6 1.8 30.5 2170
27 1.2 2.0 2.0 37.1 3200
Circular or compacted circular stranded conductors. (4 Core: Up to and including 25mm2; 5 Core and above: All).
Sector shaped stranded conductors. (4 Core: 35mm2 and above)
A6
PVC-INSULATED POWER CABLE
INSTALLED IN AIR
Current Ratings for PVC Insulated, PVC-Sheathed, Unarmoured Cables
600/1000V MS 274/BS 6346
Single core Two core Three and four core
Nominal
area of Three cables spaced # Three cables trefoil touching Approx. volt Approx. volt
Current Current
conductor Current Approx. volt drop Current Approx. volt drop drop per amp drop per amp
rating rating
rating per amp per metre rating per amp per metre per metre per metre
mm2 amp mV Amp mV Amp mV amp mV
1.5
2.5
4
6
10 66 4.30 56 3.80
16 86 2.80 73 2.40
25 116 1.70 97 1.50
35 145 1.30 120 1.10
50 185 0.83 170 0.82 170 0.94 150 0.82
70 235 0.60 220 0.58 220 0.66 185 0.57
95 300 0.47 270 0.43 265 0.49 230 0.42
120 345 0.40 310 0.35 305 0.40 265 0.35
150 395 0.35 360 0.30 350 0.34 305 0.29
185 460 0.33 420 0.25 410 0.29 350 0.25
240 585 0.32 495 0.22 485 0.24 415 0.21
300 680 0.31 575 0.19 550 0.21 475 0.18
400 780 0.28 660 0.18 630 0.19 550 0.17
500 890 0.27 760 0.16
630 1030 0.25 870 0.15
800 1170 0.23 990 0.15
1000 1290 0.22 1100 0.14
# Adjacent cable sufaces separated by one cable diameter.
A7
PVC-INSULATED POWER CABLE
LAID DIRECT IN GROUND
Current Ratings for PVC Insulated, PVC-Sheathed, Unarmoured Cables
600/1000V MS 274/BS 6346
Single core
Two core Three and four core
Nominal Three cables spaced # Three cables trefoil touching
area of
Approx. Approx. Approx. Approx.
conductor Current Current Current Current
volt drop per volt drop per volt drop per volt drop per
rating rating rating rating
amp per metre amp per metre amp per metre amp per metre
mm2 amp mV amp mV amp mV amp mV
1.5
2.5
4
6
10 79 4.30 67 3.80
16 104 2.80 88 2.40
25 135 1.70 117 1.50
35 165 1.30 140 1.10
50 190 0.83 180 0.82 195 0.94 165 0.82
70 235 0.60 220 0.58 245 0.66 200 0.57
95 280 0.47 265 0.43 285 0.49 245 0.42
120 320 0.40 300 0.35 330 0.40 280 0.35
150 355 0.35 340 0.30 370 0.34 310 0.29
185 405 0.33 380 0.25 420 0.29 350 0.25
240 470 0.32 440 0.22 485 0.24 410 0.21
300 530 0.31 495 0.19 550 0.21 460 0.18
400 610 0.28 565 0.18 620 0.19 520 0.17
500 680 0.27 630 0.16
630 780 0.25 700 0.15
800 880 0.23 770 0.15
1000 980 0.22 850 0.14
# Adjacent cable surfaces separated by one cable diameter
A8
PVC-INSULATED POWER CABLE
ALLOWABLE SHORT CIRCUIT CURRENTS FOR PVC INSULATED CABLE
100
90
80
70
60
50
40
30
20
0.5 SEC.
1 SEC. 10
9.0
8.0
2 SEC.
7.0
3 SEC. 6.0
4 SEC.
5.0
5 SEC.
SHORT CIRCUIT CURRENT (kA)
4.0
3.0
2.0
1.0
0.1154A
l =
t
A9
PVC-INSULATED
CABLE
SAMA KEBEL SDN BHD
Application
Single core, non-sheathed general purpose cables are installed in surface mounted or
embedded conduits or similar closed systems. The cables are suitable for use in
channels with cover, fixed protected installation in or on lighting fittings and inside
appliances, up to 1000V ac or up to 750 V to earth, dc.
B1
PVC-INSULATED CABLE
300/500V, PVC Insulated, Non-Sheathed Internal Wiring Cables
Application
Single core, non-sheathed internal wiring cables are for fixed protected installation,
inside appliances and in or on lighting fittings. The cables are suitable for installation
in surface mounted or embedded conduits. The cables are used only for signaling or
control circuits.
B2
PVC-INSULATED CABLE
300/500V, PVC Insulated, PVC Sheathed Cables
Application
PVC insulated, PVC sheathed cables are for fixed installation in walls, on boards and in
channels, or embedded in plaster. The cables are not suitable for outdoor use or
embedding in concrete.
B3
PVC-INSULATED CABLE
300/500V, PVC Insulated, PVC Sheathed Cables
B4
PVC-INSULATED CABLE
300/500V, PVC Insulated, PVC Sheathed Cables
B5
PVC-INSULATED CABLE
300/500V, PVC Insulated, PVC Sheathed Cables, Flat Twin & 3-Core without Earth Continuity Conductor
Application
Flat twin & 3-Core, PVC insulated, PVC sheathed cables without protective conductor
are suitable for fixed installation in walls, on boards and in channels, or embedded in
plaster.
Construction : Technical Data :
Conductor : Single solid wire or circular stranded plain Voltage : 300/500V
annealed copper wire acc. to MS 69/BS 6360 Temperature : Maximum 70oC
Insulation : PVC (polyvinyl chloride) compound type TI1 Reference : MS 136 / BS 6004
acc. to MS 138/BS 7655 Testing Voltage : 2000V
Identification Two core – Red and Black Min. Bending Radius : 8 X Overall Diameter
of cores : Three core – Red, Yellow, Blue
Laying Up : Cores laid parallel
Sheath : PVC (polyvinyl chloride) compound type T6
acc. to MS 138/BS 7655
Colour : Black, Grey or White
(Termite protection sheathing upon request)
(Rodent protection sheathing upon request)
(UV protection sheathing upon request)
(Flame Retardant sheathing upon request)
B6
PVC-INSULATED CABLE
300/500V, PVC Insulated, PVC Sheathed Cables, Flat Twin & 3-Core with Earth Continuity Conductor
Application
Flat twin & 3-Core, PVC insulated, PVC sheathed cables with protective conductor are
suitable for fixed installation in walls, on boards and in channels, or embedded in
plaster.
Construction : Technical Data :
Conductor : Single solid wire or circular stranded plain Voltage : 300/500V
annealed copper wire acc. to MS 69/BS 6360 Temperature : Maximum 70oC
Insulation : PVC (polyvinyl chloride) compound TI1 acc. to Reference : MS 136 / BS 6004
MS 138/BS 7655 Testing Voltage : 2000V
Identification Two core – Red and Black Min. Bending Radius : 8 X Overall Diameter
Of cores : Three core – Red, Yellow, Blue
Laying Up : Cores laid parallel with earth continuity
conductor in between the two cores at the
same plane
Sheath : PVC (polyvinyl chloride) compound type T6
acc. to MS 138/BS 7655
Colour : Black, Grey or White
(Termite protection sheathing upon request)
(Rodent protection sheathing upon request)
(UV protection sheathing upon request)
(Flame Retardant sheathing upon request)
B7
PVC-INSULATED CABLE
RATING FACTORS
Ratings Factors for Gouprs of More Than One Circuit of Single-Core Cables, or More Than One
Multicore Cable
Rating Factor
Method of Installation Number of Circuits or Multicore Cables
2 3 4 5 6 7 8 9 10 12 14 16 18 20
Enclosed or bunched and clipped
0.80 0.70 0.65 0.60 0.57 0.54 0.52 0.50 0.48 0.45 0.43 0.41 0.39 0.38
direct to a non-metallic surface
Touching 0.85 0.79 0.75 0.73 0.72 0.72 0.71 0.70
Single layer clipped to
a non-metallic surface
Space * 0.94 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Single layer multicore
Touching 0.86 0.81 0.77 0.75 0.74 0.73 0.72 0.71 0.70
on a perforated metal
cable tray, vertical or
Space * 0.91 0.89 0.88 0.87 0.87
horizontal
Single layer single- Horizontal 0.90 0.85
core on a perforated
metal cable tray, Vertical 0.85
touching
Single layer multicore touching on
0.86 0.82 0.80 0.79 0.78 0.78 0.78 0.77
ladder supports
* Spaced by a clearance between adjacent surfaces of at least one cable diameter (D e). Where the horizontal clearance between adjacent cables
exceeds 2De no correction factor need be applied.
B8
PVC-INSULATED CABLE
CURRENT CARRYING CAPACITY
mm2 A A A A A A A A
1 11 10 13 11.5 15 13.5 17 14.5
1.5 14 13 16.5 15 19.5 17.5 22 18.5
2.5 18.5 17.5 23 20 27 24 30 25
4 25 23 30 27 36 32 40 34
6 32 29 38 34 46 41 51 43
10 43 39 52 46 63 57 70 60
16 57 52 69 62 85 76 94 80
25 75 68 90 80 112 96 119 101
35 92 83 111 99 138 119 148 126
B9
PVC-INSULATED CABLECAPACITY
CURRENT CARRYING
VOLTAGE DROP
Voltage Drop for Single-Core PVC-Insulated Cables, Non-Armoured, with or without Sheath
to MS 136/BS 6004
o
Conductor operating temperature : 70 C
Method of Installation
Conductor Cross-
S cables d.c.
Enclosed in Enclosed in
Clipped direct or on
conduit etc. in or Spaced* conduit etc. in or In trefoil Flat spaced*
trays, touching
on a wall on a wall
B 10
PVC-INSULATED
INSTRUMENTATION CABLE
MULTIPAIR &
MULTICORE
PVC-INSULATED INSTRUMENTATION CABLE
300/500V, Type 1, PVC-Insulated Multicore & Multipair Instrumentation Unarmoured Cables
Application
Instrumentation unarmoured cables are generally used in the petroleum and
petrochemical industries. These cables are generally for indoor control applications
and they are designed for use in intrinsically safe system. The cables are individually
and/or overall shielded for greater isolation and noise reduction. The cables are
suitable for continuous operation at a maximum conductor temperature of 70oC.
C1
PVC-INSULATED INSTRUMENTATION CABLE
300/500V, Type 1, PVC-Insulated Multicore & Multipair Instrumentation Unarmoured Cables
C2
PVC-INSULATED INSTRUMENTATION CABLE
300/500V, Type 1, PVC-Insulated Multicore & Multipair Instrumentation Unarmoured Cables
C3
PVC-INSULATED INSTRUMENTATION CABLE
300/500V, Type 2, PVC-Insulated Multicore & Multipair Instrumentation Armoured Cables
Application
Instrumentation armoured cables are generally used in the petroleum and petrochemical industries. These
cables are suitable for burial underground and they are designed for use in intrinsically safe system. The
cables are individually and/or overall shielded for greater isolation and noise reduction. The cables are
suitable for continuous operation at a maximum conductor temperature of 70 oC.
Construction : Technical Data :
Conductor : Circular stranded plain annealed copper Voltage : 300/500V
wire acc. to BS 6360 Reference : BS 5308 : Part 2
Insulation : PVC (polyvinyl chloride) compound type TI1 Temperature : Maximum 70oC
acc. to BS 7655 Ambient Temperature : Maximum -20oC
Identification of Two core – Red and Black Testing Voltage : 1000V
cores: Three core - Red, Yellow, Blue Minimum Insulation Individual conductors-
Four core – Red, Yellow, Blue, Black Resistance : 25 M/km at 20oC
Five core and above – (number) 1, 2, 3, 4, Between individual
5……, and the number shall be blue or black screens -
printed on White cores 1 M/km at 20oC
Identification of Single pair – Black and White Maximum Mutual Adjacent cores –
pairs: Multi pairs – Black and (number) 1, 2, 3, 4, Capacitance : 250 pF/m at 1 kHz
5……, and the number shall be blue or black Maximum Capacitance to 400 pF/m at 1 kHz
printed on White cores Screen :
Pair Screen : Aluminium polyester tape with metallic side Min. Bending Radius : 8 X Overall Diameter
2
(optional) downward in contact with a 0.5mm tinned
copper drain wire
Laying Up : Cores stranded together. Where necessary,
binder tapes and non hygroscopic fillers may
be applied
Overall Screen : Aluminium polyester tape with metallic side
(optional) downward in contact with a 0.5mm2 tinned
copper drain wire
Bedding : Extruded PVC compound
Colour : Black
Armour : Consist of a single layer of galvanized steel
wires
Sheath : PVC (polyvinyl chloride) compound type TM1
acc. to BS 7655
Colour : Black or Grey
* Anti-termite sheathing upon request
* FR-PVC (reduced propagation PVC)
to IEC 332-3 sheathing upon request
* LSHF (low smoke halogen free) sheathing
upon request
C4
PVC-INSULATED INSTRUMENTATION CABLE
300/500V, Type 2, PVC-Insulated Multicore & Multipair Instrumentation Armoured Cables
C5
PVC-INSULATED INSTRUMENTATION CABLE
300/500V, Type 2, PVC-Insulated Multicore & Multipair Instrumentation Armoured Cables
C6
FLEXIBLE CORDS
Application
PVC insulated, non sheathed flexible cords are for installation in domestic areas,
kitchens and offices. The cables are also for usage in household equipments, eg.
washing machines, hair dryers, refrigerators, cookers and heaters. The cables are able
to withstand medium mechanical stress and frequent twisting and bending. The cables
are not suitable for permanent external installation nor for use directly or indirectly
underground.
F1
PVC-INSULATED FLEXIBLE CORDS
PVC-Insulated, PVC Sheathed Flexible Cord
Application
PVC insulated, PVC sheathed flexible cords are suitable for indoor small electrical
appliances and instruments. The cables are capable of withstanding medium
mechanical stress and frequent twisting and bending. The cables are not suitable for
permanent external installation nor for use directly or indirectly underground.
Electrical Characteristics
Nominal Number
Thickness Thickness Approx Approx Cond. Insulation
Rated cross-sectional and
Type of of overall net Resistance Resistance
voltage area of diameter
insulation oversheath diameter weight Max. at Min. at
conductor of wires
20oC 70oC
V mm2 no/mm mm mm mm kg/km /km M /km
Parallel Twin 0.50 16/0.20 0.5 0.6 3.3 x 5.2 33 39 0.012
Sheathed 0.75 24/0.20 0.5 0.6 3.6 x 5.6 40 26 0.010
2-Core Circular 0.50 16/0.20 0.5 0.6 5.2 40 39 0.012
Sheathed 0.75 24/0.20 0.5 0.6 5.6 50 26 0.010
300/300
3-Core Circular 0.50 16/0.20 0.5 0.6 5.5 50 39 0.012
Sheathed 0.75 24/0.20 0.5 0.6 6.0 60 26 0.010
4-Core Circular 0.50 16/0.20 0.5 0.6 6.0 60 39 0.012
Sheathed 0.75 24/0.20 0.5 0.6 6.5 75 26 0.010
Parallel Twin
0.75 24/0.20 0.6 0.8 4.0 x 6.4 45 26 0.011
Sheathed
0.50 16/0.20 0.6 0.8 6.1 55 39 0.013
0.75 24/0.20 0.6 0.8 6.5 65 26 0.011
2-Core Circular 1.00 32/0.20 0.6 0.8 6.9 75 19.5 0.010
Sheathed 1.25 40/0.20 0.7 0.8 7.4 85 15.6 0.010
1.50 30/0.25 0.7 0.8 7.5 90 13.3 0.010
2.50 50/0.25 0.8 1.0 9.4 140 7.98 0.009
300/500 0.75 24/0.20 0.6 0.8 6.9 75 26 0.011
1.00 32/0.20 0.6 0.8 7.3 85 19.5 0.010
3-Core Circular
1.25 40/0.20 0.7 0.9 8.0 110 15.6 0.010
Sheathed
1.50 30/0.25 0.7 0.9 8.5 115 13.3 0.010
2.50 50/0.25 0.8 1.1 10.2 180 7.98 0.009
0.75 24/0.20 0.6 0.8 7.5 90 26 0.011
4-Core Circular 1.00 32/0.20 0.6 0.9 8.2 110 19.5 0.010
Sheathed 1.50 30/0.25 0.7 1.0 9.3 150 15.6 0.010
2.50 50/0.25 0.8 1.1 11.0 216 7.98 0.009
F2
PVC-INSULATED FLEXIBLE CORDS
450/750V, Single Core PVC-Insulated Flexible Cord
Application
Single core PVC insulated flexible cords are suitable for installation in trays, trunking,
lighting units or inside switching and control equipments. The cables are suitably used
for voltages up to 1000V A.C.
F3
SWITCHGEAR AND CONTROL PANEL WIRES
600/1000V, Single Core, PVC Flexible Cables
Application
Single core, PVC flexible wires are suitable for the wiring of switch, control, metering,
relay and instrument panels of power switchgear, and for such purposes as internal
connections in rectifier equipment and in motor starters and controllers
F4
LOW SMOKE HALOGEN FREE FLEXIBLE WIRE
600/1000V, Single Core, LSHF Flexible Wire
Application
Single core, LSHF flexible wire is suitable for installation in switch cabinets, appliances
and devices for communication technologies, household appliances, construction of
power generation and transformers, machine construction, railway technologies and
particularly suitable for internal wiring of railway vehicles.
F5
TP SDI FLEXIBLE CABLES
600/1000V, Single Core, TP Insulated, TP Sheathed Flexible Cables
Application
TP insulated, TP sheathed flexible cables are suitable for wiring of switch, control,
metering, relay and instrument panels of power switchgear, transformers, battery leads,
battery chargers, electric forklifts, earth and electrode leads for welding. These cables
have lighter weight than conventional thermoset rubber. Hence, they are easy to move
and carry, and less expensive to ship or truck.
F6
XLPE-INSULATED
POWER CABLE
SAMA KEBEL SDN BHD
Application
Power cables for electricity supply are installed in open air, underground, in cable
ducts, outdoor and indoors, power stations, for industry and distribution boards as well
as in subscriber networks where mechanical damages are not to be expected. The
cables are suitable for continuous operation at a maximum conductor temperature of
90oC.
X1
XLPE-INSULATED POWER CABLE
600/1000V, XLPE Insulated, PVC Sheathed Unarmoured Cables
Electrical Characteristics
Nominal
Number Cond. Resistance
cross- Thickness Thickness Approx Approx Short
No. of and
sectional of of overall net Reactance Circuit
cores diameter D. C. at 50 Hz at
area of insulation oversheath diameter weight at 50 Hz Current
of wires 20oC 90oC
conductor for 1 sec.
no mm2 no/mm mm mm mm kg/km /km /km /km kA
16 7/1.70 0.7 1.4 9.7 210 1.15 1.47 2.28
25 7/2.14 0.9 1.4 11.3 310 0.727 0.927 0.0979 3.57
35 19/1.53 0.9 1.4 12.5 415 0.524 0.669 0.0934 5.00
50 19/1.78 1.0 1.4 13.8 540 0.387 0.494 0.0905 7.15
70 19/2.14 1.1 1.4 15.7 750 0.268 0.342 0.087 10.0
95 19/2.52 1.1 1.5 18.0 1025 0.193 0.247 0.0851 13.5
120 37/2.03 1.2 1.5 19.6 1265 0.153 0.196 0.0837 17.1
150 37/2.25 1.4 1.6 22.0 1575 0.124 0.160 0.0837 21.4
1
185 37/2.52 1.6 1.6 24.0 1885 0.0991 0.128 0.0826 26.4
240 61/2.25 1.7 1.7 27.0 2560 0.0754 0.0988 0.0812 34.3
300 61/2.52 1.8 1.8 30.0 3175 0.0601 0.0801 0.0801 42.9
400 61/2.85 2.0 1.9 33.5 4050 0.047 0.0643 0.0792 57.2
500 61/3.20 2.2 2.0 37.5 5090 0.0366 0.0521 0.0785 71.5
630 127/2.52 2.4 2.2 42.2 6550 0.0283 0.0428 0.0776 90.0
800 127/2.85 2.6 2.3 47.0 8290 0.0221 0.0363 0.0759 114.0
1000 127/3.20 2.8 2.4 52.0 10455 0.0176 0.0317 0.0749 143.0
16 7/1.70 0.7 1.8 17.2 515 1.15 1.47 0.0761 2.28
25 7/2.14 0.9 1.8 20.8 680 0.727 0.927 0.0683 3.57
35 19/1.53 0.9 1.8 19.3 850 0.524 0.669 0.0656 5.00
50 19/1.78 1.0 1.8 21.5 1125 0.387 0.494 0.0651 7.15
70 19/2.14 1.1 1.8 24.5 1580 0.268 0.342 0.0637 10.0
95 19/2.52 1.1 1.9 27.4 2125 0.193 0.247 0.0616 13.50
2
120 37/2.03 1.2 2.0 30.4 2665 0.153 0.196 0.0613 17.10
150 37/2.25 1.4 2.2 34.0 3250 0.124 0.160 0.0618 21.40
185 37/2.52 1.6 2.3 37.6 4080 0.0991 0.129 0.0623 26.40
240 61/2.25 1.7 2.5 42.3 5130 0.0754 0.0993 0.0612 34.30
300 61/2.52 1.8 2.6 46.8 6310 0.0601 0.0807 0.0605 42.90
400 61/2.85 2.0 2.9 52.6 8130 0.0470 0.0650 0.0603 57.20
2
Circular or compacted circular stranded conductors (Single core: All; 2 core: Up to and including 25mm )
2
Sector shaped stranded conductors (2 core: 35mm and above)
X2
XLPE-INSULATED POWER CABLE
600/1000V, XLPE Insulated, PVC Sheathed Unarmoured Cables
150 37/2.25 1.4 2.3 38.9 4750 0.124 0.160 0.0618 21.40
185 37/2.52 1.6 2.4 43.5 5925 0.0991 0.129 0.0623 26.40
240 61/2.25 1.7 2.6 48.8 7840 0.0754 0.0996 0.0612 34.30
300 61/2.52 1.8 2.8 54.0 9760 0.0601 0.0809 0.0605 42.90
400 61/2.85 2.0 3.0 61.0 11985 0.0470 0.0653 0.0603 57.20
150 37/2.25 1.4 2.4 44.0 6405 0.124 0.160 0.0618 21.40
185 37/2.52 1.6 2.6 49.5 8010 0.0991 0.129 0.0623 26.40
240 61/2.25 1.7 2.8 55.8 10500 0.0754 0.0996 0.0612 34.30
300 61/2.52 1.8 3.0 61.3 13070 0.0601 0.0809 0.0605 42.90
400 61/2.85 2.0 3.3 68.5 16120 0.0470 0.0653 0.0603 57.20
2
Circular or compacted circular stranded conductors. (Up to and including 25mm )
2
Sector shaped stranded conductors. (35mm and above)
X3
XLPE-INSULATED POWER CABLE
600/1000V, XLPE Insulated, PVC Sheathed Armoured Cables
Application
Power cables for electricity supply are installed in open air, underground, in cable
ducts, outdoor and indoors, power stations, for industry and distribution boards as well
as in subscriber networks where there is a risk of mechanical damage. The cables are
suitable for continuous operation at a maximum conductor temperature of 90 oC.
Construction : Technical Data :
Conductor : Circular stranded, circular compact stranded Voltage : 600/1000V
or sector shaped stranded plain annealed Temperature : Maximum 90oC
copper wire acc. to IEC 60228 class 2 Reference : IEC 60502-1
Insulation : XLPE (cross-linked polyethylene) acc. to Testing Voltage : 3500V
IEC 60502-1 Min. Bending Radius : 10 X Overall Diameter
Identification Single core – Black or Natural
of cores: Two core – Red and Black
Three core – Red, Yellow, Blue
Four core – Red, Yellow, Blue, Black
Laying Up : Cores stranded together. Where necessary,
Binder tapes and non-hygroscopic fillers may
be applied
Bedding : Extruded black PVC (polyvinyl chloride)
compound or lapped PVC tapes
Colour: Black
Armour : Single core - Consist of a single layer of non-
magnetic material, such as aluminium wire
Two core and above – Consist of a single layer
of galvanized steel wires
Sheath : PVC (polyvinyl chloride) compound type ST2
acc. to IEC 60502-1
Colour: Black
(Termite protection sheathing upon request)
(Rodent protection sheathing upon request)
(UV protection sheathing upon request)
(Flame Retardant sheathing upon request)
X4
XLPE-INSULATED POWER CABLE
600/1000V, XLPE Insulated, PVC Sheathed Armoured Cables
120 37/2.03 1.2 1.8 24.5 1600 0.153 0.196 0.101 17.10
150 37/2.25 1.4 1.8 27.5 1910 0.124 0.159 0.0999 21.40
185 37/2.52 1.6 1.8 30.5 2330 0.0991 0.128 0.0975 26.40
1
240 61/2.25 1.7 1.9 33.0 2985 0.0754 0.0982 0.0946 34.30
300 61/2.52 1.8 1.9 36.0 3700 0.0601 0.0793 0.0920 42.90
400 61/2.85 2.0 2.1 40.5 4790 0.0470 0.0632 0.0923 57.20
500 61/3.20 2.2 2.2 44.5 5885 0.0366 0.0509 0.0903 71.50
630 127/2.52 2.4 2.3 49.0 7480 0.0283 0.0415 0.0878 90.00
120 37/2.03 1.2 2.2 37.5 4010 0.153 0.196 0.0609 17.10
150 37/2.25 1.4 2.3 40.8 4735 0.124 0.160 0.0618 21.40
185 37/2.52 1.6 2.5 45.8 6120 0.0991 0.129 0.0623 26.40
240 61/2.25 1.7 2.7 50.8 7650 0.0754 0.0993 0.0612 34.30
300 61/2.52 1.8 2.8 54.8 9120 0.0601 0.0807 0.0605 42.90
2
Circular or compacted circular stranded. (Single core: All; 2 Core: Up to and including 25mm )
2
Sector shaped stranded conductors (2 Core: 35mm and above)
X5
XLPE-INSULATED POWER CABLE
600/1000V, XLPE Insulated, PVC Sheathed Armoured Cables
120 37/2.03 1.2 2.3 42.5 5510 0.153 0.196 0.0609 17.10
150 37/2.25 1.4 2.5 48.0 6990 0.124 0.160 0.0618 21.40
185 37/2.52 1.6 2.6 52.5 8460 0.0991 0.129 0.0623 26.40
240 61/2.25 1.7 2.8 58.0 10610 0.0754 0.0996 0.0612 34.30
300 61/2.52 1.8 3.0 63.5 12900 0.0601 0.0809 0.0605 42.90
120 37/2.03 1.2 2.5 49.0 7480 0.153 0.196 0.0609 17.10
150 37/2.25 1.4 2.6 53.5 8925 0.124 0.160 0.0618 21.40
185 37/2.52 1.6 2.8 58.5 10800 0.0991 0.129 0.0623 26.40
240 61/2.25 1.7 3.0 65.5 13800 0.0754 0.0996 0.0612 34.30
300 61/2.52 1.8 3.2 70.0 16800 0.0601 0.0809 0.0605 42.90
2
Circular or compacted circular stranded conductors. (Up to and including 25mm )
2
Sector shaped stranded conductors. (35mm and above)
X6
XLPE-INSULATED POWER CABLE
INSTALLED IN AIR
Current Ratings for XLPE Insulated, PVC-Sheathed, Unarmoured Cables
600/1000V IEC 60502-1
Single core Two core Three and four core
Two cables spaced # Three cables
Nominal Trefoil touching Laid flat spaced # Approx. Approx.
area of Approx. Current volt drop Current volt drop
conductor Current volt drop Approx. volt Approx.
rating per amp rating per amp
rating per amp Current drop Current volt drop
per metre per metre
per metre rating per amp rating per amp
per metre per metre
mm2 amp mV amp mV Amp mV amp mV amp mV
16 115 2.90 96 2.50
25 150 1.80 130 1.60
35 180 1.30 160 1.10
50 255 1.00 215 0.85 250 0.88 225 0.98 190 0.85
70 330 0.72 270 0.61 325 0.64 280 0.69 245 0.60
95 410 0.56 340 0.45 395 0.49 350 0.51 300 0.44
120 480 0.46 400 0.36 470 0.41 405 0.41 350 0.36
150 550 0.40 460 0.31 540 0.36 465 0.35 400 0.30
185 640 0.35 530 0.26 620 0.32 540 0.29 465 0.25
240 760 0.31 630 0.22 740 0.29 630 0.24 560 0.21
300 900 0.29 740 0.19 880 0.27 740 0.21 630 0.19
400 1060 0.27 870 0.17 1040 0.26 840 0.19 720 0.18
500 1250 0.26 1020 0.16 1210 0.25
630 1480 0.25 1140 0.15 1420 0.24
800 1620 0.24 1260 0.14 1560 0.23
1000 1770 0.23 1400 0.13 1700 0.22
#Adjacent cable surfaces separated by one cable diameter
X7
XLPE-INSULATED POWER CABLE
LAID DIRECT IN GROUND
Current Ratings for XLPE Insulated, PVC-Sheathed, Unarmoured Cables
600/1000V IEC 60502-1
Single core Two core Three and four core
Two cables spaced # Three cables
Nominal Approx. Approx.
Trefoil touching Laid flat spaced # volt drop volt drop
area of Approx. Current Current
conductor Current volt drop Approx. volt drop Approx. per amp per amp
rating rating
rating per amp Current per amp per metre Current volt drop per per
per metre rating rating per amp metre metre
Trefoil Flat per metre
2
mm amp mV amp mV mV amp mV amp mV amp mV
16 130 2.80 110 2.50
25 165 1.80 135 1.60
35 200 1.30 165 1.10
50 265 1.00 215 0.85 0.87 230 0.88 235 0.97 200 0.84
70 325 0.72 265 0.61 0.62 285 0.64 295 0.68 245 0.59
95 380 0.56 310 0.44 0.45 330 0.49 360 0.50 295 0.44
120 440 0.46 360 0.36 0.37 375 0.41 400 0.41 340 0.35
150 495 0.40 405 0.31 0.32 425 0.36 465 0.34 375 0.29
185 570 0.35 455 0.26 0.27 485 0.32 510 0.29 430 0.25
240 660 0.31 530 0.22 0.23 570 0.29 610 0.24 500 0.21
300 740 0.29 610 0.19 0.21 640 0.27 670 0.21 560 0.18
400 850 0.27 690 0.17 0.19 740 0.26 770 0.19 660 0.16
500 950 0.26 780 0.16 0.18 840 0.25
630 1100 0.25 890 0.15 0.17 940 0.24
800 1210 0.24 980 0.14 0.16 1030 0.23
1000 1320 0.23 1070 0.13 0.15 1130 0.22
#Adjacent cable surfaces separated by one cable diameter
Current Ratings for XLPE Insulated, PVC-Sheathed, Armoured Cables
600/1000V IEC 60502-1
Single core*
Two core Three and four core
Nominal Two cables spaced Three cables trefoil touching
area of
Approx. Approx. Approx. Approx.
conductor Current Current Current Current
volt drop per volt drop per volt drop per volt drop per
rating rating rating rating
amp per metre amp per metre amp per metre amp per metre
mm2 amp mV amp mV amp mV amp mV
16 130 2.90 105 2.60
25 165 1.90 140 1.60
35 200 1.30 165 1.20
50 255 0.99 220 0.86 235 1.00 200 0.87
70 315 0.70 270 0.61 295 0.70 245 0.61
95 375 0.53 320 0.46 355 0.52 295 0.45
120 430 0.43 365 0.37 400 0.42 335 0.36
150 475 0.37 405 0.32 445 0.35 375 0.30
185 540 0.31 455 0.27 500 0.29 430 0.25
240 620 0.26 520 0.23 585 0.24 495 0.21
300 700 0.24 585 0.21 650 0.22 550 0.19
400 770 0.21 650 0.19 730 0.19 620 0.18
500 850 0.20 720 0.18
630 930 0.19 780 0.17
800 1020 0.18 880 0.16
1000 1110 0.17 930 0.15
*Single core cables are aluminium wire armoured
Basic Assumptions
o o
Ground temperature : 25 C Ground thermal resistivity : 1.2 C m/W
Depth of laying : 0.5 metre ( to the centre of cable or trefoil group of cables)
o
Maximum conductor temperature : 90 C
Rating Factors for other Ground Temperature
o
Ambient air temperature C 15 20 25 30 35 40 45
Rating factor 1.07 1.04 1.0 0.96 0.92 0.88 0.83
X8
XLPE-INSULATED POWER CABLE
RUN IN SINGLE WAY DUCTS
Current Ratings for XLPE Insulated, PVC-Sheathed, Unarmoured Cables
600/1000V IEC 60502-1
Single core Two core Three and four core
Two cables: ducts Three cables: ducts touching,
Nominal touching trefoil or flat
Approx. Approx.
area of Approx. Trefoil touching Current volt drop Current volt drop
conductor Current volt drop Approx. volt drop rating per amp rating per amp
rating per amp Current per amp per metre per metre per metre
per metre rating
Trefoil Flat
mm2 Amp mV amp mV mV amp mV amp mV
16 110 2.9 87 2.5
25 130 1.8 120 1.6
35 160 1.3 135 1.1
50 245 1.1 225 0.93 0.94 190 0.98 165 0.85
70 300 0.80 275 0.70 0.72 240 0.69 200 0.60
95 350 0.65 320 0.56 0.57 285 0.51 240 0.44
120 405 0.55 370 0.48 0.50 330 0.41 280 0.36
150 455 0.50 415 0.43 0.45 370 0.35 310 0.30
185 520 0.45 465 0.39 0.41 425 0.29 355 0.25
240 610 0.40 540 0.35 0.37 485 0.24 410 0.21
300 690 0.37 610 0.32 0.35 560 0.21 465 0.19
400 790 0.35 700 0.30 0.32 630 0.19 530 0.18
500 900 0.32 790 0.28 0.31
630 1030 0.30 900 0.26 0.29
800 1130 0.28 990 0.25 0.28
1000 1230 0.26 1080 0.24 0.27
X9
XLPE-INSULATED POWER CABLE
ALLOWABLE SHORT CIRCUIT CURRENTS FOR XLPE INSULATED CABLE
16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000
100
90
80
70
60
50
40
30
20
0.5 SEC.
1 SEC.
2 SEC. 10
9.0
3 SEC.
4 SEC. 8.0
7.0
6.0
5 SEC.
5.0
4.0
SHORT CIRCUIT CURRENT (kA)
3.0
2.0
1.0
l = 0.143A
t
X 10
FIRE RESISTANT
CABLE
SAMA KEBEL SDN BHD
Application
Non-armoured fire-resistant cables are for general application in power and signal
wirings where mechanical damages are not to be expected, not only for emergency
circuits but for areas where maintaining circuit integrity and/or control of fire spread
are deemed desirable. With a high level of fire resistance, the cables are durable and
flexible enough to be pulled into conduit and trunking, and are the cost effective
alternative to standard cable wiring systems. Due to its low smoke halogen free
compound which ensures flame retardant, low toxicity and acidic gases and smoke
emission, the cables increase chances of survival during fire breakout and are ideal for
installation in existing metal conduit or trunking to update existing alarm and lighting
systems previously wired in PVC cables in the public, commercial and industrial
environments. The cables are RoHS compliance and are suitable for continuous
operation at a maximum conductor temperature of 70 oC.
Z1
FIRE-RESISTANT CABLE
600/1000V, LSHF Insulated, LSHF Sheathed Non-Armoured Fire Resistant Cables
Z2
FIRE-RESISTANT CABLE
600/1000V, LSHF Insulated, LSHF Sheathed Non-Armoured Fire Resistant Cables
Z3
FIRE-RESISTANT CABLE
600/1000V, LSHF Insulated, LSHF Sheathed Armoured Fire Resistant Cables
Application
Armoured fire-resistant cables offer the advantages of an armoured 600/1000V rated,
low smoke halogen free cable and are for general application in power and signal
wirings, not only for emergency circuits but for areas where maintaining circuit
integrity and/or control of fire spread are deemed desirable. Due to its low smoke
halogen free compound which ensures flame retardant, low toxicity and acidic gases
and smoke emission, the cables increase chances of survival during fire breakout. The
cables are suitable for use in public, commercial and industrial environments where
maintaining life, equipment and structures are critical. The cables are RoHS
compliance and are suitable for continuous operation at a maximum conductor
temperature of 70oC.
Construction : Technical Data :
Conductor : Circular stranded plain annealed copper Voltage : 600/1000V
wire acc. to IEC 60228/BS6360 Temperature : Maximum 90oC
Flame Barrier Layer : Mica based fire-resistant tapes Reference : IEC 60502-1
Insulation : LSHF (low smoke halogen free) compound IEC 60331,
Identification of Single core - Natural SS 299 / BS 6387 CWZ
cores : Two core – Red and Black Testing Voltage : 3500V
Three core – Red, Yellow, Blue Min. Bending Radius : 10 X Overall Diameter
Four core – Red, Yellow, Blue, Black
Laying Up : Cores stranded together. Where necessary,
binder tapes and non hygroscopic fillers may
be applied
Bedding : Extruded LSHF (low smoke halogen free)
compound
Colour : Natural
Armour : Single core - Consist of a single layer of non-
magnetic material, such as aluminium wire
Two core and above – Consist of a single layer
of galvanized steel wires
Sheath : LSHF (low smoke halogen free) compound;
Colour : Orange
(Termite protection sheathing upon request)
(Rodent protection sheathing upon request)
Z4
FIRE-RESISTANT CABLE
600/1000V, LSHF Insulated, LSHF Sheathed Armoured Fire Resistant Cables
Z5
FIRE-RESISTANT CABLE
600/1000V, LSHF Insulated, LSHF Sheathed Armoured Fire Resistant Cables
Electrical Characteristics
Nominal Number
Thickness Thickness Approx Approx Short
No. of cross- and Cond. Insulation
of of overall net Circuit
cores sectional diameter Resistance Resistance
insulation oversheath diameter weight Current
area of wires Max at 20oC Min at 70oC
for 1 sec.
no mm2 no/mm mm mm mm kg/km /km /km kA
1.5 7/0.53 0.7 1.8 15.9 455 12.1 0.010 0.215
2.5 7/0.67 0.7 1.8 16.8 520 7.41 0.0084 0.358
4 7/0.85 0.7 1.8 18.0 635 4.61 0.0070 0.572
6 7/1.04 0.7 1.8 20.0 740 3.08 0.0059 0.858
10 7/1.35 0.7 1.8 21.6 1135 1.83 0.0047 1.430
16 7/1.70 0.7 1.8 24.0 1395 1.15 0.0039 2.288
25 7/2.14 0.9 1.8 28.5 2070 0.727 0.0039 3.515
3 35 19/1.53 0.9 1.8 31.0 2485 0.524 0.0034 5.005
50 19/1.78 1.0 1.9 34.5 3090 0.387 0.0032 7.150
70 19/2.14 1.1 2.1 40.5 4010 0.268 0.0030 10.010
95 19/2.52 1.1 2.2 45.0 5460 0.193 0.0026 13.585
120 37/2.03 1.2 2.3 49.0 6520 0.153 0.0026 17.160
150 37/2.25 1.4 2.5 55.0 8310 0.124 0.0026 21.450
185 37/2.52 1.6 2.7 60.0 9920 0.0991 0.0026 26.455
240 61/2.25 1.7 2.9 67.0 12350 0.0754 0.0025 34.320
1.5 7/0.53 0.7 1.8 16.6 520 12.1 0.010 0.215
2.5 7/0.67 0.7 1.8 17.7 605 7.41 0.0084 0.358
4 7/0.85 0.7 1.8 19.5 800 4.61 0.0070 0.572
6 7/1.04 0.7 1.8 21.0 1000 3.08 0.0059 0.858
10 7/1.35 0.7 1.8 23.5 1350 1.83 0.0047 1.430
16 7/1.70 0.7 1.8 26.4 1700 1.15 0.0039 2.288
25 7/2.14 0.9 1.8 31.0 2465 0.727 0.0039 3.515
4 35 19/1.53 0.9 1.9 34.2 3000 0.524 0.0034 5.005
50 19/1.78 1.0 2.0 39.0 3900 0.387 0.0032 7.150
70 19/2.14 1.1 2.2 44.0 5290 0.268 0.0030 10.010
95 19/2.52 1.1 2.3 49.0 6720 0.193 0.0026 13.585
120 37/2.03 1.2 2.5 55.0 8570 0.153 0.0026 17.160
150 37/2.25 1.4 2.7 60.0 10250 0.124 0.0026 21.450
185 37/2.52 1.6 2.8 66.0 12275 0.0991 0.0026 26.455
240 61/2.25 1.7 3.1 75.0 16000 0.0754 0.0025 34.320
Z6
LSHF-INSULATED POWER CABLE
ALLOWABLE SHORT CIRCUIT CURRENTS FOR LSHF INSULATED CABLE
16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000
100
90
80
70
60
50
40
30
20
0.5 SEC.
1 SEC.
2 SEC. 10
9.0
3 SEC.
4 SEC. 8.0
7.0
6.0
5 SEC.
5.0
4.0
SHORT CIRCUIT CURRENT (kA)
3.0
2.0
1.0
l = 0.143A