You are on page 1of 7
DOOSAN-MAN B&W Page : 1/6 Client : SAMSUNG HEAVY INDUSTRIES CO., LTD. Engine Type: 6S70ME-C8 IMO Regulation : Tier 4 Hull Number — : 1909/4910/1923/1924/1925/1926 Subject : Flow and level sensors Note : Attachments: fefer to the Revision History and contents for drawing list 5 4 3 2 5 5 es ay [Added HNT023/24725/26 on page 116, according to yard request aoe ols “ (Yard comment, 10.04.14 e-mail) i 20100128 wet | JS et |First issued. oO Date | Drawn | Chk'd | App'd Description Rev. DOOSAN-MAN B&W Page :_1/6-#1 REVISION HISTORY DATE |REV DESCRIPTION 20100128 | 0 |Firstissued 20100416 | 1 added HN1923/24/25/26 on page 1/7, according to yard request(Yard comment, "10.04.14 e-mail) ed @S70ME-C8 PART Electric Doc. DESCRIP- No.| EW05-4981-1 TION Flow and level sensors Doosan Engine oN @® @ o So WD DOOSAN-MAN B&W Page : 2/6 CONTENTS Bev DESCRIPTION ONG. No SHEET 0 FLOW AND LEVEL swIToH ENO6-4061-0 1 © A/C ATER DRAIN LEVEL SHTCH 13-000426-6 1 OF. LEAKAGE LEVEL swiTcH 13-000427-5 1 © P.C.0 NON-FLOW SWITCH 33-010868-3 1 © LeveL surToH 29-011600-1 1 ENE 6S7OME-C8 PART Electric | DESCRIP- No.| EWO05-4981-1 TION Flow and level sensors Doosan Engine oN @® @ o So WD 3.COLOR + I.CONTACT CAPACITY = AC ZS0V 0.25A, DC |I0V 0.258 2.MAX. PRESSURE & MAX. TEMPERATURE 12.5 BAR AT 135°C 3.0 BAR AT 100°C MUNSELL NO. 7.5 BG 7/2 4.NAME PLATE S98} : 25x75 : TAG NO. POR 2 9! EIKO HIGA! Sigleet 7 3/6 Drawing no Description BODY 2 COVER 1 |.cs 3 FLOAT I SUS 304 4 MAGNET HOLDER 1 SUS 304 5 REED SWITCH CHAMBER i SUS 304 6 ‘STOPPER I SUS 304 7 CABLE GLAND (DIN TYPE) I BS 8 GASKET 2 | Mos 9 TEST LEVER 2 [es SPECIFICATION DOOM ESE ORY | SE 2oneosoe PUSAN See Toma ART WeicHT ADDED 5 20060117 DOUSANT SH [ofS TEST CABLE GLAND DIN TYPES SARI! 5 K ck By 9960502 DU0SAN| OESET| ORISTTOIST FiesT issuep 0 Date —[DERRSN| Drawn [ones | Ae] pypeDagsipéjen oF Revision ee r Doosan Engine A t 8 i S © i2hy ie ig hicamnad AS A/C WATER DRAIN LEVEL SWITCH 2 sere Te irovine Fost erator eae Te] =" 13-000426 Pe Toren a @o- Om: F 1 | 2 3 | 4 Page : 4/6 Drowing no. Weight ze | eooy 2 FLOAT 1 [5 206 3 TEST LEVER BODY 1 | Feo Ue 4 MAGNET 1 | aLnico 5 MICRO SWITCH 1 6 CABLE GLAND (DIN TYPED 1 [ec AL COVER 1 | wece NOW ears ee PACKING | aseestos ~ =| [9 NAME PLATE 1 [eras al = PECIFICATION Nee PALE 1. INSTALLATION = SIDE MOUNTING *TAG NO. 2. MAX. TEMPERATURE (120°C 6 Hr eens 3. MAX, PRESSURE : 2BAR 4. CONTACT # SA, I25V 5. a'Ty : 6. WIRING DIAGRAM 7. NAME PLATE at * TAG NO. POR MQ Yb BISA! sie! MARK AT LOW LEVEL MARK AT HIGH LEVEL, Jf 1 a @o-e@ DOOSAN] Sse | ere | aisier ll 20091201 a Cee ee Toe | TEMPERATURE. CORRECTED 5 SAN] Se | Ole | 2S & |E | 2o0eosoe [OO0SANt Sue | ole | 28 Tera aco 4 i § | eecoorao isi one Toit Tote reer ramen : 7 i Date | Comp. [Orown [GHk*3| Appa] Geseriptien of Revision Rev a |f i HES leesfun] Doosan Engine 3 exter aorerraTT ah Taner ORTRG TT be 5 : u | [ae Tar i je © a frm ih i” Pas F.0 LEAKAGE LEVEL SWITCH ge laa == 5 13-000427 tae “op TAD Growing 7 WS AOE COrTRCE Oy ROT 3 4 Page : 5/6 PF 3/4" Drawing no Description Q'ty Material} Weight Size 25 SPECIFICATION PLEASURING PRINCIPLE : POWER SUPPLY RELAY OUTPUT CURRENT CONSUMPT | ON (1) MATERIAL NO.1-NO.N P.C.0 NON FLOW SWITCH DETAIL A VIBRATION : DPDT DRY CONTACT 110mA "SF" FOR SENSOR FAULT (2) RED LED "AL" FOR ALARM (3) GREEN LED OPERATION TEMPTURE OPERATION PRESSURE "NOR" FOR NORMAL COND! TION -20 ~ 80°C BRASS OR STEEL BLACK, ENGRAVED TO BE ATTACHED AT DELIVERY ELECTRICAL CONNECTION A * P.C.0 DRAIN HOPPER 3234 P.C.0 NON-FLOW SWITCH TIP Mal SYS SENSING HE PE. 4 | 1-1 | FSS SWICH UP(H) DIP | 1-2 | TIME DELAY uP (1) WTC 1-3 | SESOR SENSING SELECT) UP(D) 2 | RELAY a DC 24V IN 4 |DRY CONTACT OUT INDICATION JDOOSAN| EUs | wae | vat 20100126) Fawut [were [eee [alee [ote steed : Doosan eae [ole [alzel 120090722 HANUL Fuse ee | eee Error corrected 2 DOOSAN| VE} eve | lsu, + 200803519 HANUL | Beal ee] ee First issued 0 Date [Conp. [brew | ont | Apps Description of Revision Ron odosian Doosan Engine ; aa rs <= i a © 14 five: fi Scare: Sires P.C.O NON-FLOW SWITCH i 1:2 AS /e 0035 33-010868 ig @ @ O.0:@. 3 4 Page : 6/6 110 ISO 228/1-1-G1A L~ 4 XxX XXX No Drawing no Description Q'ty |Moterial] Weight Size ELECTRICAL CONNECTION za|2a +28 Tae pot correct by Fane THD Draving Wet 4 |DRY CONTACT OUT 3 [Dc 24V IN 2 | RELAY ol TAG No “| DESCRIPTION 1 1-3 |SESOR SENSING SELECT] DOWN(W)) DIP | 1-2 | TIME DELAY UP(1) WI TCI DETAIL A 1-1 | FSS SWICH UP CH) SPECIFICATION 1) MODEL : SVFLS 2) PLEASURING PRINCIPLE : VIBRATION 20090722)00SAN S82 | ole | IE | error corrected 1 3) POWER SUPPLY : DC 24 SM Bea oe ee 4) RELAY OUTPUT : DPDT WET CONTACT pooso7 sprout Sez eee See First issued 0 5) CURRENT CONSUMPT | ON 110mA Date Comp. | Drawn | Chk'd | App'd Description of Revision Rev 6) INDICATION : (1) RED LED "SF" FOR SENSOR FAULT INDICATION (2) RED LED ‘AL* FOR ALARM odosian Doosan Engine (3) GREEN LED "NOR" FOR NORMAL CONDITION oor Tae TT astarTar RST Tear rane Fe 8) OPERATION PRESSURE : 10bar — = aes 9) PROTECTION : IP56 4 O11 10) NAME PLATE : (1) MATERIAL : BRASS OR STEEL ee LEVEL SWITCH (2) LETTER : BLACK, ENGRAVED : AS (3) TO BE ATTACHED AT DELIVERY We Brewin We Tan ae re 0035 33-011690 @ @.O:A:

You might also like