Overview
SIM  2.0 Thermocouple (TC) input type modules can be interfaced to any of the commonly
available TC types; i.e. J,K,B,E,R,S,T,N to generate isolated 0-10V/4-20mA output. These
modules comprise of in-built Cold Junction Compensation (CJC) calibrated to track the TC
mV response at room temperature. The TC mV v/s V/I output is a linearly proportional
value. The module can be calibrated to I/P v/s O/P range according to the user
requirements.
The user has the option of implementing non-linearity error compensation of the TC
response in the Data Acquisition System interfaced to the Voltage/Current output of the
modules to achieve better accuracy in temperature measurements.
Technical Specifications
Features
Thermocouple Input Options:
Input Signal J Type(0 to +1200°C)* Factory Set  Input Thermocouple types :
K Type(0 to +1370°C)* * Max. Temperature J, K, B,E,R,S,T,N
E Type(0 to +1000°C)* Range
 In-built Cold junction
B Type(800 to +1820°C)*
R Type(0 to +1750°C)* compensation (CJC).
S Type(0 to +1750°C)*  0-10V/4-20mA output
T Type(0 to +400°C)*
calibration provided as per
N Type(0 to +1300°C)*
Input Resistance 100 K Ohm user requirement of input
Output Signal Output Options: 0- +5V, 0- +10V, Factory Set temp. range.
0-20mA, 4 20mA.
>1 K Ohm  Thermocouple non-linearity
Load Resistance For Output Voltage
For Output Current 500 Ohm Max. not compensated
Performance Accuracy ±0.2% of Span at 25°C
 24VDC Power Supply.
a. Electronic Linearity 0.1%
System
<0.01% / °C  Slim & compact design.
Temperature Drift
Response Time < 1Sec  Energy Efficient Module.
Calibration Zero & Span (Trimpot )
 Low Noise & Low drift for
b. Thermocouple Non-linearity Compensation : Not provided
long term stability
General Specifications
 2kV 3 Port Isolation.
Isolation 2KV - 3 Port.

Power Supply Voltage 24VDC(nominal)


Operating Range 18 to 36 VDC
Ripple < 100mVpp
Power Supply Current 150mA.Max
Enclosure ABS Plastic, 35 Single Output W - 22.5mm
mm DIN Rail Mounted. H - 75mm
IP40 Protection class. D - 110mm

Operating temp. range 0 – 55°C


Applications
Storage temp. range 0 – 80°C  Heating Control Systems
Relative Humidity 0– 90%  Temperature monitoring
RH Non-Condensing systems
Max. Altitude 3000 mts above MSL  Data Acquisition Systems
Ordering Information:
Isolation Input Output Supply I/P Signal O/P Signal
Isolation
(I) Type Type 24VDC Range Range
I I/P O/P Supply XX X 3P
Type J :XJ
( 0 – +1200º C)* 0-5V:05
Type K :XK
( 0 – +1370º C)*
Type E :XE
(0 – +1000º C)* 0-10V:10
I Type B :XB
V ( 800 – +1820º C)*
Type R :XR
4-20mA:42
( 0 – +1750º C)*
2D 3P
TC Type S :XS
I ( 0 – +1750º C)*
Type T :XT 0-20mA:20
(0 - +400º C)*
Type N :XN
( 0 -+1300º C)*
*: Max. Measurement Range; X: Actual Range of TC

Mechanical Details:

Single Input & Single Output Converter

PIN Details PIN Details Related Products


1 +Input 5 +Output  Thermocouple Converters (Linearized Output)
 Programmable Input TC types J,K,B,E,R,S,T,N
2 -Input 6 -Output  RTD to 0-10V/4-20mA Converters
3 NC 7 +24VDC  Programmable Indicators- Thermocouple Input,
4 NC 8 GND  Re-transmission 4-20mA output, MODBUS interface

About Us
CANOPUS INSTRUMENTS is engaged in the development & manufacturing of industrial automation and process control
instrumentation products. The product areas cover mainly Analog Signal Conditioning Instruments for Process Automation,
Embedded Systems & Ultrasonic Equipment for Non-Destructive Testing Applications.
All the CANOPUS range of products are designed and manufactured with special care, to ensure trouble free performance
in Industrial applications where Electromagnetic Interference (EMI) & Harsh environmental conditions exist.
Today these products come to our customers with the quality assurance and tech-support in H/W & S/W, which has
evolved with our experience of over 25 years, to ensure uninterrupted operation in field conditions. This has enabled us to
successfully create an installed base of tens of thousands units performing satisfactorily in a wide spectrum of Critical Real time
Industrial applications all over India and in other parts of the world.
INNOVATION – QUALITY- RELIABILITY

Address: #2 & 3, ‘Vishwas’, Karnik Road, Off. Murbad Road, Kalyan (W) 421 301, Maharashtra, INDIA.
Tel: +91-251-2322576 / 2203389 Telfax: +91-251- 2325849.
Email: marketing@canopusinstruments.com Website: www.canopusinstruments.com

You might also like