Report # E160510426

EMC TEST REPORT


For

Applicant Shenzhen Vians Electric Lock Co., Ltd.

Room 202-7, No.13 Building,Wangtang


Address Industrial Zone, Xinwei Village, Xili Town,
Nanshan District, Shenzhen City, China.

Product Electromagnetic Lock Series

VI-60A/T, VI-180A/B, VI-180AS/BS;


VI-180EA/ES, VI-280A/B, VI-280AS/BS;
Models No.
VI-280EA/ES, VI-380A/B, VI-380AS/BS;
VI-500A/AS, VI-750A/AS.

Trademark Vians

Issued by
Shenzhen KTS Testing Services Ltd
4F, Fuqiang Bldg. Xixiang Road Crossing, Zone 62,
Xixiang Town, Baoan District, Shenzhen, China

STEVEN GWOK / Project Manager


Date of Test: May 30, 2016 to May 31, 2016
Date of Issue: June 2, 2016

Page 1/36
Report # E160510426

TABLE OF CONTENTS

Clause Page

0. GENERAL INFORMATION .................................................................................................. 5-6


1. TEST SUMMARY ................................................................................................................. 7-8
2. TEST INSTRUMENT LIST.................................................................................................. 9-10
3. DISTURBANCES VOLTAGES AT AC POWER PORTS ....................................................... 11
3.1. Test Set-up ..................................................................................................................... 11
3.2. Test Method .................................................................................................................... 11
3.3. Test Limits....................................................................................................................... 11
3.4. EUT Configuration on Test ............................................................................................. 11
3.5. Operating Condition of EUT ........................................................................................... 12
3.6. Test Procedure ............................................................................................................... 12
3.7. Test Result ...................................................................................................................... 12
4. RADIATED DISTURBANCES AT ENCLOSURE PORTS ............................................... ….13
4.1. Test Set-up .................................................................................................................... 13
4.2. Test Method ................................................................................................................... 13
4.3. Test Limit ....................................................................................................................... 13
4.4. EUT Configuration on Test ............................................................................................ 13
4.5. Operating Condition of EUT .......................................................................................... 13
4.6. Test Procedure .............................................................................................................. 14
4.7. Test Result..................................................................................................................... 14
5. HARMONIC CURRENTS AT AC POWER PORTS ............................................................... 15
5.1. Test Set-up .................................................................................................................... 15
5.2. Test Method ................................................................................................................... 15
5.3. Test Limit ....................................................................................................................... 15
5.4. EUT Configuration on Test ............................................................................................ 15
5.5. Operating Condition of EUT .......................................................................................... 15
5.6. Test Procedure .............................................................................................................. 15
5.7. Test Result..................................................................................................................... 15
6. VOLTAGE FLUCTUATIONS & FLICKERS AT AC POWER PORTS.................................... 16
6.1. Test Set-up .................................................................................................................... 16
6.2. Test Method ................................................................................................................... 16
6.3. Test Limit ....................................................................................................................... 16
6.4. EUT Configuration on Test ............................................................................................ 16
6.5. Operating Condition of EUT .......................................................................................... 16
6.6. Test Procedure .............................................................................................................. 16
6.7. Test Result..................................................................................................................... 16
7. ELECTROSTATIC DISCHARGE AT ENCLOSURE PORTS................................................. 17
7.1. Test Set-up ..................................................................................................................... 17
7.2. Test Method .................................................................................................................... 17
7.3. Test Level and Performance Criterion ............................................................................ 17
7.4. EUT Configuration on Test ............................................................................................. 18
7.5. Operating Condition of EUT ........................................................................................... 18
7.6. Test Procedure ............................................................................................................... 18
7.7. Test Result ...................................................................................................................... 19

Page 2/36
Report # E160510426

TABLE OF CONTENTS

Clause Page

8. RADIATED ELECTROMAGNETIC FIELD AT ENCLOSURE PORTS .................................. 20


8.1. Test Set-up ..................................................................................................................... 20
8.2. Test Method .................................................................................................................... 20
8.3. Test Level and Performance Criterion ............................................................................ 20
8.4. EUT Configuration on Test ............................................................................................. 20
8.5. Operating Condition of EUT ........................................................................................... 20
8.6. Test Procedure ............................................................................................................... 21
8.7. Test Result ...................................................................................................................... 21
9. FAST TRANSIENTS AT SIGNAL PORTS & AC/DC POWER PORTS ................................. 22
9.1. Test Set-up ..................................................................................................................... 22
9.2. Test Method .................................................................................................................... 22
9.3. Test Level and Performance Criterion ............................................................................ 22
9.4. EUT Configuration on Test ............................................................................................. 22
9.5. Operating Condition of EUT ........................................................................................... 23
9.6. Test Procedure ............................................................................................................... 23
9.7. Test Result ...................................................................................................................... 23
10. SURGES AT AC/DC MAINS PORTS .................................................................................. 24
10.1.Test Set-up .................................................................................................................... 24
10.2.Test Method ................................................................................................................... 24
10.3.Test Level and Performance Criterion ........................................................................... 24
10.4.EUT Configuration on Test ............................................................................................ 24
10.5.Operating Condition of EUT .......................................................................................... 25
10.6.Test Procedure .............................................................................................................. 25
10.7.Test Result..................................................................................................................... 25
11. RADIO FREQUENCY VOLTAGE AT SIGNAL PORTS & AC/DC POWER PORTS ........... 26
11.1.Test Set-up .................................................................................................................... 26
11.2.Test Method ................................................................................................................... 26
11.3.Test Level and Performance Criterion ........................................................................... 26
11.4.EUT Configuration on Test............................................................................................. 26
11.5.Operating Condition of EUT........................................................................................... 27
11.6.Test Procedure .............................................................................................................. 27
11.7.Test Result ..................................................................................................................... 27
12. POWER FREQUENCY MAGNETIC FIELDS AT ENCLOSURE PORTS ............................ 28
12.1.Test Set-up .................................................................................................................... 28
12.2.Test Method ................................................................................................................... 28
12.3.Test Level and Performance Criterion ........................................................................... 28
12.4.EUT Configuration on Test ............................................................................................ 28
12.5.Operating Condition of EUT .......................................................................................... 28
12.6.Test Procedure .............................................................................................................. 28
12.7.Test Result..................................................................................................................... 29

Page 3/36
Report # E160510426

TABLE OF CONTENTS

Clause Page

13. VOLTAGE DIPS AND INTERRUPTIONS AT AC POWER PORTS .................................... 30


13.1.Test Set-up .................................................................................................................... 30
13.2.Test Method ................................................................................................................... 30
13.3.Test Level and Performance Criterion ........................................................................... 31
13.4.EUT Configuration on Test ............................................................................................ 31
13.5.Operating Condition of EUT .......................................................................................... 31
13.6.Test Procedure .............................................................................................................. 31
13.7.Test Result..................................................................................................................... 31
APPENDIX 1 Test Results for Disturbances Voltages at AC Power Ports ................. 32-33
APPENDIX 2 Test Results for Radiated Disturbances at Enclosure Ports ................ 34-35
APPENDIX 3 Sample Photos .............................................................................................. 36

Page 4/36
Report # E160510426

0. General Information
0.1 Manufacturer's General Information:

Shenzhen Vians Electric Lock Co., Ltd.


Room 202-7, No.13 Building,Wangtang Industrial Zone,
Xinwei Village, Xili Town, Nanshan District, Shenzhen City, China.

0.2 Equipment Under Test (EUT)

Model No.: VI-280AS


Serial No.: 432953
Electric ratings: Supplied by external DC 24V or DC 12V
All tests performed on the model VI-280AS and considered representative of all models.
The 24 volt sample was tested after checking the 12 volt samples for worst case.

0.3 Test standard(s) and/or regulation(s)

All tests were performed according to the following harmonized standards:

EN 61000-6-1:2007
Electromagnetic compatibility (EMC) -
Part 6-1: Generic standards -Immunity for residential, commercial and light-industrial
environments

EN 61000-6-3:2007/A1:2011/AC:2012
Electromagnetic compatibility (EMC) -
Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial
environments

0.4 EU Declaration of Conformity:

The above Standard has been identified as the harmonized standard that needs to be met before
declaring conformity with the EMC Directive 2014/30/EU. This Report per this Standard can
serve as part of the documentation to be placed in the product Technical File as required by the
Directive. The existence of a Technical File is required to support the EU Declaration of
Conformity for this product. In addition to the Technical File, the Directive requires a "Declaration
of Conformity" to the applicable standards (and/or Directives) and the affixing of the CE Marking
to the product or its packaging.

0.5 Applicant's Documentation:


The manufacturer must keep the following documents on file and readily available if requested
by the competent authorities.
1. Declaration of Conformity.
2. Copy of this Report.
3. Material such as design specifications, schematics, drawings, BOM's, operators' guides, and
other supporting documentation in the Technical File. This file must be kept for 10 years after the
last unit is produced and marketed in order to meet European Union requirements in effect at the
publishing date of this report.
0.6 Test Facility
All measurement facilities used to collect the measurement data are located at World
Standardization Certification & Testing Co., Ltd. The facility has been accredited and approved
by following approval agencies according to ISO/IEC 17025.

Page 5/36
Report # E160510426

IC (Canada): The certificate registration number is 7700A-1;


FCC (USA): The certificate registration number is 131628;
VCCI (Japan): The certificate registration number is C-4128 and R-3684, G-837;
TUV (Germany): The certificate registration number are UA50138086-0001 and UA50138086-002;
CNAS (China): The certificate registration number is L3732.

0.7 Test Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2:
Measurement Frequency Uncertainty
Conducted emissions 9kHz to 30MHz +/- 3.59dB
Radiated electromagnetic 9kHz to 30MHz +/- 4.77dB
30MHz to 230MHz +/- 4.77dB
Horizontal
230MHz to 300MHz +/- 4.93dB
Radiated emissions
30MHz to 230MHz +/- 5.04dB
Vertical
230MHz to 1000MHz +/- 4.93dB
This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.

0.8 Principle of Configuration Selection

For Emission Test:


The equipment under test (EUT) was configured to measure its highest possible radiation level.
The test modes were adapted accordingly in reference to the instructions for use.
For Immunity Test:
The equipment under test (EUT) was configured to have its highest possible susceptibility against
the tested phenomena. The test modes were adapted accordingly in reference to the instructions
for use.

0.9 Peripherals

AC/DC power adaptor (Direct Plug-in): Input AC 100-240V 50/60Hz, Output DC 24V/1.0A.

0.10 Test Mode

The equipment under test (EUT) was tested under normal loaded operation.

Page 6/36
Report # E160510426

1. Test Summary

Test items Test specification Test Method Verdict


Disturbance tests (EN 61000-6-3)
Disturbance voltage at AC power
150 kHz – 30 MHz CISPR 16-2-1:2014 Pass
ports
Radiated disturbances at 30 MHz – 230 MHz
CISPR 16-2-3:2014 Pass
enclosure ports 230 MHz – 1 000 MHz
Harmonic current test at AC
0 kHz – 2 kHz IEC 61000-3-2:2014 Pass
power ports
Voltage fluctuation and flicker at
0 kHz – 2 kHz IEC 61000-3-3:2013 Pass
AC power ports
Immunity tests at enclosure port (EN 61000-6-1)
Electrostatic Discharge ±4 kV CD, ±8 kV AD B* IEC 61000-4-2:2008 Pass
3 V/m, 80MHz-1000MHz,
3 V/m, 1.4GHz-2,0GHz,
Radiated electromagnetic field A* IEC 61000-4-3:2010 Pass
1 V/m, 2,0GHz-2,7GHz
80% AM (1kHz)
Power-frequency magnetic field 50/60Hz 3A/m A* IEC 61000-4-8:2009 Pass
Immunity tests at signal ports (EN 61000-6-1)
±0.5 kV 5/50 Tr/Th ns
Fast transients B* IEC 61000-4-4:2012 Pass
5 kHz repetition frequency
3V, 0.15-80MHz,
Radio frequency voltage A* IEC 61000-4-6:2013 Pass
80% AM (1kHz)
Immunity tests at input and output DC power ports (EN 61000-6-1)
±0.5 kV 5/50 Tr/Th ns
Fast transients B* IEC 61000-4-4:2012 Pass
5 kHz repetition frequency
±0.5 kV line to earth
Surges ±0.5 kV line to line B* IEC 61000-4-5:2014 Pass
1,2/50(8/20)
3V, 0.15-80MHz,
Radio frequency voltage A* IEC 61000-4-6:2013 Pass
80% AM (1kHz)
Immunity tests at input and output AC power ports (EN 61000-6-1)
±1.0 kV 5/50 Tr/Th ns
Fast transients B* IEC 61000-4-4:2012 Pass
5 kHz repetition frequency
±2.0 kV line to earth
Surges ±1.0 kV line to line B* IEC 61000-4-5:2014 Pass
1,2/50(8/20)
3V, 0.15-80MHz,
Radio frequency voltage A* IEC 61000-4-6:2013 Pass
80% AM (1kHz)
0% residual volatge
B*
0.5 cycle;
0% residual volatge
Voltage dips B*
1 cycle;
IEC 61000-4-11:2004 Pass
70% residual volatge
C*
25/30 at 50/60Hz cycle
0% residual volatge
Voltage short interruptions C*
250/300 at 50/60Hz cycle
AD= Air Discharge CD= Contact Discharge N/A=Not Applicable AM= Amplitude modulated

Page 7/36
Report # E160510426

A*, B*, C* means following performance criteria:

Performance criterion A: The apparatus shall continue to operate as intended during the test. No
degradation of performance or loss of function is allowed below a performance level (or permissible
loss of performance) specified by the manufacturer, when the apparatus is used as intended.

Performance criterion B: The apparatus shall continue to operate as intended after the test. No
degradation of performance or loss of function is allowed below a performance level (or permissible
loss of performance) specified by the manufacturer, when the apparatus is used as intended.

Performance criterion C: Temporary loss of function is allowed, provided the function is self-
recoverable or can be restored by the operation of the controls, or by any operation specified in the
instructions for use.

Page 8/36
Report # E160510426

2. TEST INSTRUMENT LIST


2.1 For Conducted Emission Test

No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval
1. Test Receiver Rohde & Schwarz ESCS30 828985/018 2015/08/17 1 Year
2. L.I.SN Rohde & Schwarz ESH2-Z5 834549/005 2015/08/17 1 Year
3. 50Ω Coxial Switch Anritsu MP59B M20531 2015/08/17 1 Year
4. Pulse Limiter Rohde & Schwarz ESH3-Z2 100006 2015/08/17 1 Year
5. Voltage Probe Rohde & Schwarz TK9416 N/A 2015/08/17 1 Year
2.2 For Radiated Emission Test
No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal Interval
1 EMI Test Receiver R&S ESI 26 100009 2015/08/17 1 Year
2 Spectrum ANRITSU MS2661C 62001409 2015/08/17 1 Year
Analyzer 15
3 Cable Schwarzbeck AK9513 ACRX1 2015/08/17 1 Year
4 Cable Rosenberger N/A FP2RX2 2015/08/17 1 Year
5 Cable Schwarzbeck AK9513 ARPX1 2015/08/17 1 Year
6 Cable Schwarzbeck AK9513 ARPX2 2015/08/17 1 Year
7 Bilog Antenna Schwarzbeck VULB9163 142 2015/08/17 1 Year
8 EMI Power line DUOJI EME FNF 201B16 N/A 2015/08/17
1 Year
filter
9 EMI Power line JIANLI DL-40C N/A 2015/08/17
1 Year
filter
10 50 Coaxial Anritsu Corp MP59B 61002372 2015/08/17
1 Year
Switch 48

2.3 For Harmonic / Flicker Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal Interval
1 Power Frequency
HAEFELY PHF555 080419-03 2015/08/17 1 Year
Test System

2.4 For Electrostatic Discharge Immunity Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval
1. ESD Tester HAEFELY PESD1600 H708159 2015/08/17 1 Year

2.5 For RF Field Strength Susceptibility Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval

1. Signal Generator HP 8648A 3625U00573 2015/08/17 1 Year

2.6 For Electrical Fast Transient/Burst Immunity Test

No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval

1. Burst Tester HAEFELY PEFT4010 080981-16 2015/08/17 1 Year

2. Coupling Clamp HAEFELY IP-4A 147147 2015/08/17 1 Year

Page 9/36
Report # E160510426

2.7 For Surge Immunity Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval

1. Surge Tester HAEFELY PSURGE4.1 080107-04 2015/08/17 1 Year

2.8 For Injected Currents Susceptibility Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval

1. Simulator EMTEST CWS500C 0900-12 2015/08/17 1 Year

2. CDN EMTEST CDN-M2 5100100100 2015/08/17 1 Year

3. CDN EMTEST CDN-M3 0900-11 2015/08/17 1 Year

4. Injection Clamp EMTEST F-2031-23MM 368 2015/08/17 1 Year

5. Attenuator EMTEST ATT6 0010222A 2015/08/17 1 Year

2.9 For Magnetic Field Immunity Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval

1. Magnetic Field HAEFELY MAG100 250040.1 2015/08/17 1 Year


Tester

2.10 For Voltage Dips and Interruptions Test


No. Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Interval

1. Dips Tester HAEFELY Pline1610 083732-12 2015/08/17 1 Year

Page 10/36
Report # E160510426

3. DISTURBANCE VOLTAGES AT AC POWER PORTS


3.1. Test Set-up
3.1.1. Block Diagram of connection between EUT and simulation

Enclosure Port

Power Port EUT Signal Port

3.1.2. Test configuration

3.2 Test Method


The test was performed in accordance with CISPR 16-2-1:2014, Initial measurements were
performed in peak and average detection modes on the live line. Any emissions recorded within
30dB of the relevant limit lines were re-measured using quasi-peak and average detection on the
live and neutral lines with the worst case recorded in the table of results.

3.3 Test Limit

Frequency Limits (dBV)


MHz Quasi-peak Level Average Level
0.15 - 0.50 66 - 56* 59 - 46*
0.50 - 5.00 56 46
5.00 - 30.00 60 50

Note: * Decreasing linearly with logarithm of the frequency.

3.4 EUT Configuration on Test


The equipment under test (EUT) was configured to measure its highest possible radiation level.
The test modes were adapted accordingly in reference to the instructions for use.

Page 11/36
Report # E160510426

3.5 Operating Condition of EUT


3.5.1 Setup the EUT as shown in Section 3.1.
3.5.2 Turn on the power of all equipment.
3.5.3 Let the EUT work in loaded mode

3.6 Test Procedure


The EUT and simulators are connected to the main power through a line impedance stabilization
network (L.I.S.N.). This provides a 50ohm/50μH coupling impedance for the measuring
equipment. The peripheral devices are also connected to the main power through a L.I.S.N. that
provides a 50ohm/50μH coupling impedance with 50ohm termination.

Both sides of AC line are checked for maximum conducted interference. In order to find the
maximum emission, the relative positions of equipment and all of the interface cable s must be
change according to CISPR 16-2-1 on conducted measure. The bandwidth of the field strength
meter is set at 9 kHz.

3.7 Test Result


The frequency range 0.15 MHz to 30 MHz was investigated. The emission from the EUT was
below the specified limits. The worst case emissions are shown in Appendix 1.

Page 12/36
Report # E160510426

4. RADIATED DISTURBANCES AT ENCLOSURE PORTS


4.1 Block Diagram of Test Setup
4.1.1 Block Diagram of connection between EUT and simulation
Enclosure Port

Power Port EUT Signal Port

4.1.2. Test configuration

4.2 Test method


The test was performed in accordance with CISPR 16-2-3:2014

4.3 Test Limit

Measurement
Frequency Limits
distance (Meters)
(MHz) dB(V/m)
in SAC chamber
30 - 230 3 40
230 - 1000 3 47

Note: SAC = Semi-Anechoic Chamber

4.4 EUT Configuration on Test


The equipment under test (EUT) was configured to measure its highest possible radiation level.
The test modes were adapted accordingly in reference to the instructions for use.

4.5 Operating Condition of EUT


4.5.1 Setup the EUT as shown in section 4.1.2
4.5.2 Turn on the power of all equipment.
4.5.3 Let the EUT work in loaded mode

Page 13/36
Report # E160510426

4.6 Test Procedure


The EUT and its simulators are placed on a turn table which is 0.8 meter (or 1.5 meters) above
ground. The turn table can rotate 360 degrees to determine the position of the maximum
emission level. The EUT was positioned such that the distance from antenna to the EUT was 3
meters.

The antenna can move up and down between 1 meter and 4 meters to find out the maximum
emission level.

Both horizontal and vertical polarizations of the antenna are set on measurement. In order to find
the maximum emission, all of the interface cables must be manipulated according to CISPR
16-2-3 on radiated measurement. The receiver is measured with the quasi-peak detector. The
bandwidth of the field strength meter is set at 120 kHz.

4.7 Test Result


The frequency range 30 MHz to 1000 MHz was investigated. The emission from the EUT was
below the specified limits. The worst case emissions are shown in Appendix 2.

Page 14/36
Report # E160510426
5. HARMONIC CURRENTS AT AC POWER PORTS
5.1. Test Set-up
5.1.1. Block Diagram of connection between EUT and simulation

Enclosure Port

Power Port EUT Signal Port

5.1.2. Test configuration

5.2. Test Method


The test was performed in accordance with IEC 61000-3-2:2014.
5.3 Test Limit
Clause 7.1 Limits for Class A equipment.

5.4 Operating Condition of EUT


5.4.1 Setup the EUT as shown in section 5.1.
5.4.2 Turn on the power of all equipment.
5.4.3 Let the EUT work in loaded mode

5.5 EUT Configuration on Test


The equipment under test (EUT) was configured to measure its highest possible radiation level.
The test modes were adapted accordingly in reference to the instructions for use.

5.6 Test Procedure


5.6.1 EUT was connected to the power analyzer system. Measurement was performed to obtain the
desired harmonic parameters.
5.6.2 Record any degradation of performance.

5.7 Test Result


According to Clause 7 of EN61000-3-2, the EUT rated power is less than 75W, belong to
“equipment with a rated power of 75W or less”, therefore ‘limits are not specified in this edition of
the standards’. It is deem to full fit the requirements of the standards.
Result: The EUT is compliance with the requirements of this section.

Page 15/36
Report # E160510426
6 VOLTAGE FLUCTUATIONS & FLICKER AT AC POWER PORTS
6.1 Test Set-up
Same as section 5.1
6.2 Test Method
The test was performed in accordance with IEC 61000-3-3:2013.

6.3 Test Limit


Test item Limit
Pst 1.00
Plt 0.65
dc [%] 3.30
dmax [%] 4.00
dt [s] 0.50

6.4 Operating Condition of EUT


Same as section 5.3

6.5 EUT Configuration on Test


The equipment under test (EUT) was configured to measure its highest possible radiation level.
The test modes were adapted accordingly in reference to the instructions for use.

6.6 Test Procedure


EUT was connected to the power analyzer system. Measurement was performed to obtain the
desired flicker parameters.

6.7 Test Results


The Fluctuations and Flickers from the EUT was below the specified limits. The worst case
emission shown in table below.
EUT: Electromagnetic Lock Series Temperature: 25℃
M/N: VI-280AS Humidity: 60%
Power Supply: AC 100-240V 50/60Hz Test Mode: Loaded
Tested by: Kuo Chien Test date: May 31, 2016
Short time(Pst): 10min Flicker-meter: 10 min
Remark:-

Measured values Limits Results


Pst 0.266 1.00 PASS
Plt 0.171 0.65 PASS
dc[%] 0.139 3.30 PASS
dmax[%] 0.243 4.00 PASS
dt[s] 0.000 0.50 PASS

Page 16/36
Report # E160510426
7 ELECTROSTATIC DISCHARGES AT ENCLOSURE PORTS
7.1 Test Set-up
7.1.1 Block Diagram of connection between EUT and simulation

Enclosure Port

Power Port EUT Signal Port

7.1.2 Test configuration

7.2 Test Method


The test was performed in accordance with IEC 61000-4-2:2008.

7.3 Test Level and Performance Criterion


7.3.1 Air Discharge: ± 8kV, Contact Discharge: ± 4kV

Level Test Voltage Test Voltage


Contact Discharge (KV) Air Discharge (KV)
1. ±2 ±2
2. ±4 ±4
3. ±6 ±8
4. ±8 ± 15
X. Special Special

7.3.2 Performance criterion: B.

Page 17/36
Report # E160510426
7.4 EUT Configuration on Test
The equipment under test (EUT) was configured to have its highest possible susceptibility
against the tested phenomena. The test modes were adapted accordingly in reference to the
instructions for use.

7.5 Operating Condition of EUT


7.5.1 Setup the EUT as shown in section 7.1.2
7.5.2 Turn on the power of all equipment.
7.5.3 Let the EUT work in loaded mode

7.6 Test Procedure


7.6.1 Air Discharge:
This test is done on a non-conductive surface. The round discharge tip of the discharge electrode
shall be approached as fast as possible to touch the EUT. After each discharge, the discharge
electrode shall be removed from the EUT. The generator is then re-triggered for a new single
discharge and repeated 10 times for each pre-selected test point. This procedure shall be
repeated until all the air discharge completed.

7.6.2 Contact Discharge:


All the procedure shall be same as section 9.6.1 except that the tip of the discharge electrode
shall touch the EUT before the discharge switch is operated.

7.6.3 Indirect discharge for horizontal coupling plane


At least 20 single discharge (10 with positive and 10 with negative polarity) hall be applied to the
horizontal coupling plane, at points on each side of the EUT. The discharge electrode’s position
is vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the
coupling plane.

7.6.4 Indirect discharge for vertical coupling plane


At least 20 single discharge (10 with positive and 10 with negative polarity) shall be applied to
the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X
0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall
be applied to the coupling plane, with this plane in sufficient different positions that the four faces
of the EUT are completely illuminated.

7.7 Test Result


The measurement of the electrostatic discharge was investigated and the test result is listed on
next pages. Acceptance criterion was met and the EUT passed the test.

Page 18/36
Report # E160510426

EUT: Electromagnetic Lock Series Temperature: 25℃


M/N: VI-280AS Humidity: 61%
Test Mode: Loaded Tested by: Kuo Chien
Test Date: May 31, 2016 Remark: -

Table 1: ESD (Direct Contact)


Test Levels
Test Points Location
-2 kV +2 kV -4 kV +4 kV -8 kV +8 kV -15 kV +15 kV
Exposed metallic
B B B B / / / /
parts

Table 2: ESD (Air Discharge)


Test Levels
Test Points Location
-2 kV +2 kV -4 kV +4 kV -8 kV +8 kV -15 kV +15 kV
Exposed
B B B B B B / /
non-metallic parts

Table 3: ESD (Indirect contact HCP)


Test Levels
Test Points Location
-2 kV +2 kV -4 kV +4 kV -8 kV +8 kV -15 kV +15 kV
Front side B B B B / / / /
Back side B B B B / / / /
Left side B B B B / / / /
Right side B B B B / / / /

Table 4: ESD (Indirect contact VCP)


Test Levels
Test Points Location
-2 kV +2 kV -4 kV +4 kV -8 kV +8 kV -15 kV +15 kV
Front side B B B B / / / /
Back side B B B B / / / /
Left side B B B B / / / /
Right side B B B B / / / /

Page 19/36
Report # E160510426
8 RADIATED ELECTROMAGNETIC FIELD AT ENCLOSURE PORTS
8.1 Test Set-up
8.1.1 Block Diagram of the EUT
Enclosure Port

Power Port EUT Signal Port

8.1.2 Test configuration

8.2 Test Method


The test was performed in accordance with IEC 61000-4-3:2010.

8.3 Test Level and Performance Criterion


Test level: 3V/m, 80% AM (1kHz) for frequency range 80MHz-1000MHz and 1,4GHz-2,0GHz.
Test level: 1V/m, 80% AM (1kHz) for frequency range 2,0 GHz-2,7GHz.
Performance criterion: A

8.4 EUT Configuration on Test


The equipment under test (EUT) was configured to have its highest possible susceptibility
against the tested phenomena. The test modes were adapted accordingly in reference to the
instructions for use.

8.5 Operating Condition of EUT

8.5.1 Setup the EUT as shown in Section 8.1.


8.5.2 Turn on the power of all equipment.
8.5.3 Let the EUT work in test mode and test it.

Page 20/36
Report # E160510426

8.6 Test Procedure


The EUT and its simulators are placed on a turned table that is 0.8 meter above the ground.
The EUT is set 3 meters away from the transmitting antenna that is mounted on an antenna
tower. Both horizontal and vertical polarization of the antenna is set on test. Each of the four
sides of EUT must be faced this transmitting antenna and measured individually.
In order to judge the EUT performance, a CCD camera is used to monitor the EUT.
All the scanning conditions are as follows:

Condition of Test Remarks


----------------------------------------------------------------------
1. Fielded Strength 3 V/m & 1V/m
2. Radiated Signal Modulated
3. Scanning Frequency 80-1000MHz &1,4GHz-2,0Hz, 2,0GHz-2,7GHz
4. Sweeping rate 1%
5. Dwell Time 2 Sec.

8.7 Test Result


The measurement of the radiated immunity was investigated and the test result is shown in
following table. The acceptance criterion was met and the EUT passed the test.

EUT : Electromagnetic Lock Series Temperature : 25℃


M/N : VI-280AS Humidity : 60%
Power supply : AC 100-240V 50/60Hz Test Mode : Loaded
Tested by : Kuo Chien Test Date : May 31, 2016
Modulation:  AM, 1 KHz, 80%  Pulse  none 1 kHz, 80%

Test Level: 3 V/m (Swept frequency range from 80 MHz to 1000 MHz and 1,4GHz-2,0GHz)
Test Level: 1 V/m (Swept frequency range from 2,0GHz-2,7GHz)
Sweeping rate 1% 1%
Dwell Time 2s 2s
Positions Horizontal Vertical
Front Pass Pass
Right Pass Pass
Rear Pass Pass
Left Pass Pass
The EUT was continue to operate as intended. No loss of function or performance. The EUT
met performance criterion A during and after test.

Page 21/36
Report # E160510426

9 FAST TRANSIENTS AT SIGNAL PORTS & AC/DC POWER PORTS


9.1 Test Set-up
9.1.1 Block Diagram of the EUT

Enclosure Port

Power Port EUT Signal Port

9.1.2 Test configuration

9.2 Test Method


The test was performed in accordance with IEC 61000-4-4:2012.

9.3 Test Level and Performance Criterion


9.3.1 Test Level: ±1 kV at AC power port, ±0.5 kV at DC power port and signal port.

Open Circuit Output Test Voltage ±10%


Level On Power Supply Lines On I/O (Input/Output)
Signal data and control lines
1. 0.5 kV 0.25 kV
2. 1 kV 0.5 kV
3. 2 kV 1 kV
4. 4 kV 2 kV
X Special Special

9.3.2. Performance criterion: B.

9.4 EUT Configuration on Test


The equipment under test (EUT) was configured to have its highest possible susceptibility
against the tested phenomena. The test modes were adapted accordingly in reference to the
instructions for use.

Page 22/36
Report # E160510426
9.5 Operating Condition of EUT
9.5.1 Setup the EUT as shown in Section 9.1.
9.5.2 Turn on the power of all equipment.
9.5.3 Let the EUT work in loaded mode

9.6 Test Procedure


The EUT was arranged for Power Line Coupling and for I/O Line Coupling through a capacitive
clamp, where applicable. (Note: The I/O coupling test using a capacitive clamp is performed on
the I/O interface cables that are longer in length than 3 meters.) A metal ground plane 2.4
meter by 2.0 meter was placed between the floor and the table and is connected to the earth by
a 2.0 meter ground rod. The ground rod is connected to the test facility’s electrical earth.

9.7 Test Result


The measurement of the Electrical Fast Transients was investigated and the results are shown in
the following table. The acceptance criterion was met and the EUT passed the test.

EUT : Electromagnetic Lock Series Temperature :25℃


M/N : VI-280AS Humidity :60%
Power supply : AC 100-240V 50/60Hz Test Mode :Loaded
Tested by : Kuo Chien Test Date :May 31, 2016
Injected port at AC Mains.
Test Inject Test Inject
Injected Duration Results Injected Duration Results
Voltage Method Voltage Method
DC Cable
AC Cable ±1 kV 1 min Direct PASS Signal ±0.5 kV 1 min Direct PASS
Cable
Remark: The EUT met performance criterion B during and after test.

Page 23/36
Report # E160510426
10 SURGES AT AC/DC POWER PORTS
10.1 Test Set-up
10.1.1 Block Diagram of the EUT
Enclosure Port

Power Port EUT Signal Port

10.1.2 Test configuration

10.2 Test Method


The test was performed in accordance with IEC 61000-4-5:2014.

10.3 Test Level and Performance Criterion


10.3.1. Test level: ±2 kV line to earth at AC port,±1kV line to line at AC port and
±0.5kV at DC port

Severity Level Open-Circuit Test Voltage (kV)


1 0.5
2 1.0
3 2.0
4 4.0
* Special

10.3.2. Performance criterion: B.

10.4 EUT Configuration on Test


The equipment under test (EUT) was configured to have its highest possible susceptibility
against the tested phenomena. The test modes were adapted accordingly in reference to the
instructions for use.

Page 24/36
Report # E160510426
10.5 Operating Condition of EUT
10.5.1 Setup the EUT as shown in Section 10.1.
10.5.2 Turn on the power of all equipment.
10.5.3 Let the EUT work in loaded mode

10.6 Test Procedure


1) Set up the EUT and test generator as shown on Section 10.1.
2) For line to line coupling mode, provide a ±2kV/±1kV/±0.5kV,1.2/50us voltage surge (at
open-circuit condition) and 8/20us current surge to EUT selected points.
3) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are
conducted during test.
4) Different phase angles are done individually.
5) Record the EUT operating situation during compliance test and decide the EUT immunity
criterion for above each test.

10.7 Test Result


The measurement of the surges was investigated and the results are shown in the following table.
The acceptance criterion was met and the EUT passed the test.

EUT :Electromagnetic Lock Series Temperature : 25℃


M/N :VI-280AS Humidity : 60%
Power supply :AC 100-240V 50/60Hz Test Mode : Loaded
Tested by :Kuo Chien Test Date : May 31, 2016
Pulse voltage
Location Polarity Phase Angle No. of Pulse Result
(kV)
+ 0 5 1.0 PASS
+ 90 5 1.0 PASS
+ 180 5 1.0 PASS
AC power port + 270 5 1.0 PASS
Line to Neutral - 0 5 1.0 PASS
- 90 5 1.0 PASS
- 180 5 1.0 PASS
- 270 5 1.0 PASS
+ 0 5 2.0 N/A
+ 90 5 2.0 N/A
+ 180 5 2.0 N/A
+ 270 5 2.0 N/A
Line to Earth
- 0 5 2.0 N/A
- 90 5 2.0 N/A
- 180 5 2.0 N/A
- 270 5 2.0 N/A
DC power port + 0,90,180,270 5 0.5 PASS
DC power port - 0,90,180,270 5 0.5 PASS
Remark: The EUT met performance criterion B during and after test.

Page 25/36
Report # E160510426

11 RADIO FREQUENCY VOLTAGE AT SIGNAL PORTS & AC/DC POWER PORTS


11.1 Test Set-up
11.1.1 Block Diagram of the EUT

Enclosure Port

Power Port EUT Signal Port

11.1.2 Test configuration

11.2 Test Method


The test was performed in accordance with IEC 61000-4-6:2013.

11.3 Test Level and Performance Criterion


11.3.1 Test level: 3 V r.m.s., 80% AM (1 kHz), frequency range from 0.15MHz – 80MHz.

Level Field Strength V/m


1. 1
2. 3
3. 10
X Special

11.3.2 Performance criterion: A.

11.4 EUT Configuration on Test


The equipment under test (EUT) was configured to have its highest possible susceptibility
against the tested phenomena. The test modes were adapted accordingly in reference to the
instructions for use.

11.5 Operating Condition of EUT


11.5.1 Setup the EUT as shown in Section 11.1.
11.5.2 Turn on the power of all equipment.
11.5.3 Let the EUT work in loaded mode

Page 26/36
Report # E160510426
11.6 Test Procedure
1) Set up the EUT, CDN and test generators as shown on Section 11.1.2
2) Let the EUT work in test mode and test it.
3) The EUT are placed on an insulating support 0.1m high above a ground reference plane.
CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from EUT.
Cables between CDN and EUT are as short as possible, and their height above the ground
reference plane shall be between 30 and 50 mm (where possible).
4) The disturbance signal described below is injected to EUT through CDN.
5) The EUT operates within its operational mode(s) under intended climatic conditions after
power on.
6) The frequency range is swept from 150 kHz to 80 MHz using 3V signal level, and with the
disturbance signal 80% amplitude modulated with a 1 kHz sine wave.
7) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept
incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the
preceding frequency value.
8) Recording the EUT operating situation during compliance testing and decide the EUT
immunity criterion.

11.7 Test Result


The measurement of the Injected Currents was investigated and the results are shown in the
following table. The acceptance criterion was met and the EUT passed the test.

EUT :Electromagnetic Lock Series Temperature :25℃


M/N :VI-280AS Humidity :60%
Power supply :AC 100-240V 50/60Hz Test Mode :Loaded
Tested by :Kuo Chien Test Date :May 31, 2016

Frequency
Range Performance
Injected Position Strength Result
Criterion
(MHz)

0.15 - 80 AC power port 3V r.m.s., Unmodulated A PASS

0.15 - 80 DC power port 3V r.m.s., Unmodulated A PASS

0.15 - 80 Signal port 3V r.m.s., Unmodulated A PASS

Remark:
The EUT was continued to operate as intended. No loss of function or performance.
The EUT met performance criterion A during and after test.

Page 27/36
Report # E160510426

12 POWER FREQUENCY MAGNETIC FIELDS AT ENCLOSURE PORTS

12.1 Test Setup


12.1.1 Block Diagram of the EUT
Enclosure Port

Power Port EUT Signal Port

12.1.2 Test configuration

12.2 Test Method


The test was performed in accordance with IEC 61000-4-8:2009.

12.3 Test Level and Performance Criterion


12.3.1 Test level: 3A/m, 50/60Hz.
12.3.2 Performance criterion: A

12.4 EUT Configuration on Test


The equipment under test (EUT) was configured to have its highest possible susceptibility against the
tested phenomena. The test modes were adapted accordingly in reference to the instructions for use.

12.5 Operating Condition of EUT


12.5.1 Setup the EUT as shown in section 12.1.
12.5.2 Turn on the power of all equipment.
12.5.3 Let the EUT work in test mode and test it.

12.6 Test Procedure


The EUT shall be subjected to the Power Frequency Magnetic Fields by using the induction coil
of standard dimensions (1m x 1m) and shown in section 12.1. The induction coil shall then be
rotated by 90° in order to expose the EUT to the test field with different orientations.
Page 28/36
Report # E160510426

13.7 Test Results


The test of Power Frequency Magnetic Fields was investigated and the test result is show in
following table. The acceptance criterion was met and the EUT passed the test.

EUT : Electromagnetic Lock Series Temperature :25℃


M/N : VI-280AS Humidity :60%
Power supply : AC 100-240V 50/60Hz Test Mode :Loaded
Tested by : Kuo Chien Test Date :May 31, 2016

Coil Orientation
Test Level (A/m)
X Y Z
1 / / /
3 A A A
10 / / /
30 / / /
100 / / /
Special / / /

The EUT was continued to operate as intended. No loss of function or performance.


The EUT met performance criterion A during and after test.

Page 29/36
Report # E160510426

13 VOLTAGE DIPS AND INTERRUPTIONS AT AC POWER PORTS


13.1 Test Set-up
13.1.1 Block Diagram of the EUT

AC Mains EUT Load

13.1.2 Test configuration

13.2 Test Method


The test was performed in accordance with IEC 61000-4-11:2004.

13.3 Test Level and Performance Criterion


Test level and performance criterion as follows:

Item Specifications Performance Criterion


0% residual volatge
B
0.5 cycle;
Voltage dips at AC Mains 0% residual volatge
B
or DC Mains port 1 cycle;
70% residual volatge
C
25/30 at 50/60Hz cycle
Voltage short interruptions 0% residual volatge
C
at AC Mains or DC Mains port 250/300 at 50/60Hz cycle

Page 30/36
Report # E160510426
13.4 EUT Configuration on Test
The equipment under test (EUT) was configured to have its highest possible susceptibility
against the tested phenomena. The test modes were adapted accordingly in reference to the
instructions for use.

13.5 Operating Condition of EUT


13.5.1 Setup the EUT as shown in section 13.1.
13.5.2 Turn on the power of all equipment.
13.5.3 Let the EUT work in loaded mode

13.6 Test Procedure


1) Set up the EUT and test generator as shown on section 13.1.2
2) The interruption is introduced at selected phase angles with specified duration.
3) Record any degradation of performance.

13.7 Test Result


The measurement of the Voltage dips and interruptions was investigated and the results are shown
in the following table. The acceptance criterion was met and the EUT passed the test.

EUT :Electromagnetic Lock Series Temperature : 25℃


M/N :VI-280AS Humidity : 60%
Power supply :AC 100-240V 50/60Hz Test Mode : Loaded
Tested by :Kuo Chien Test Date : May 31, 2016
Performance
Test item Test Level Phase Angle Result
Criterion
>95% reduction, 0.5 period B PASS
Voltage Dips 0 °– 360 °
30% reduction, 25 periods C PASS
Voltage short
>95% reduction, 250 periods 0 °- 360 ° C PASS
interruptions
Remark:
The EUT was continued to operate as intended. No loss of function or performance.
The EUT met performance criterion A during and after test.

Page 31/36
Report # E160510426

Appendix 1: Test Results for Disturbances Voltages at AC Power Ports

Page 32/36
Report # E160510426

Appendix 1: Test Results for Disturbances Voltages at AC Power Ports

Page 33/36
Report # E160510426

Appendix 2: Test Results for Radiated Disturbances at Enclosure Ports

Page 34/36
Report # E160510426

Appendix 2: Test Results for Radiated Disturbances at Enclosure Ports

Page 35/36
Report # E160510426

Appendix 3: Sample Photos

Fig.1 – Model VI-280AS Fig.2 – Model VI-280AS

Fig.3 – Model VI-180B Fig.4 – Model VI-180B

Page 36/36