Professional Documents
Culture Documents
Figure 9: Relative L2 error (volume source analytical vs numerical solution Line Heat
Source with Specify heat source radius check-box selected) as a function of mesh refinement
The convergence of the relative L2 error for fine mesh cases (mh ≤10-2 m) is shown on
Figure 9. This validates the accuracy of the Line Heat Source feature with Specify heat
source radius check-box selected.