Panduit Data Center Infrastructure Topologies for At-A-Glance

Cisco Enterprise-class Platforms

Technology Impact on the Data Center Panduit® Net-Access™ Switch Cabinet Network Equipment Architectures
An optimized data center design must address the Figure 1. Production Data Center Cisco-Panduit have partnered to create enterprise
interdependencies between the logical network and infrastructure topologies for three logical data center
physical layer infrastructure. This at-a-glance provides access layer network equipment architectures:
an overview of the key design considerations. xx End of row: Approach with a modular chassis
Cisco® and Panduit have collaborated to create enter- supporting one or more racks or cabinets of servers
prise data center topologies that provide guidelines for xx Top of rack: Consists of a 1- or 2-RU switch supporting
high-performance, flexible, scalable, and reliable data server equipment within the same rack.
center design. These topologies incorporate: xx Integrated switching: Addresses blade chassis server
environments with integrated switches.
xx Network design best practices
Cisco-Panduit pod topologies provide the flexibility to
xx Physical layer infrastructure best practices
interchange architectures without substantial impact to
xx Power, cooling, and space considerations the overall data center infrastructure (Figure 3).
Cisco Network Logical Topology
xx Data center standards Figure 2 shows a network topology for deployment of
the Cisco Nexus 7000 Series switch in an data center Infrastructure Considerations
Data Center Design Overview
Data center design requires a layered approach: environment. Active Hardware
Figure 2. Places in the Network A network and infrastructure topology design determines
xx Logical network design determines overall data center active hardware requirements, which include:
capacity. Cisco Nexus 7000
10GE Core Core xx Number of routers and switches
xx Logical network design and topology determine active
xx Number of ports on each network layer
hardware and physical layer requirements.
(core, aggregation, and access)
xx Integration of active and physical layer components
xx Bandwidth per router or switch
determine facility requirements for floor space, power, Aggregation
xx Number of servers
and cooling.
Cisco Nexus 7000
Future capacity, new technologies, and industry 10GE Aggregation xx Number of ports per server
standards must be planned for and taken into account xx Bandwidth per server
throughout the design process. xx Number of storage components
Top
of Rack
Physical Layer Hardware
Network Considerations Cisco Nexus 7000 Active hardware requirements determine physical layer
1GE and 10GE
A logical network architecture design requires consider- (or connectivity) infrastructure requirements to host and
ation of the following capacity measurements: Typical Blade interconnect active components. The physical layer
Switch Access
xx Port density infrastructure includes:
xx Uplink bandwidth Cabinets Racks Cabling Cable Management
NAS Server Rack-Optimized
xx Server capacity Farm/HPC Servers Virtual Blade Switch Panduit works closely with Cisco to provide comprehen-
xx Oversubscription Cisco-Panduit topologies incorporate Cisco network sive connectivity solutions that integrate server, storage,
If these considerations are not carefully addressed, network design best practices to maximize capacity in the data and Cisco networking components. This helps ensure
bottlenecks can occur, limiting data center performance. center’s network. efficient installation and long-term interoperability.
Panduit Data Center Infrastructure Topologies for At-A-Glance

Cisco Enterprise-class Platforms

The Panduit® Net-Access™ Switch Cabinet provides the Pod Topologies and Facilities xx Flexibility to interchange use of network architectures
security and aesthetics of a cabinet with accessibility Pod topologies provide a modular and scalable solution with limited impact to the data center infrastructure.
and thermal performance comparable to an open rack. for the buildout of a data center. Key considerations for a A pod topology must be able to flexibly scale within
Features include: data center pod topology include: the limitations of a data center’s facilities. As shown in
xx Thermal ducting to provide hot/cold aisle deployments Power Cooling Space Cabling Figures 4-7, Cisco-Panduit topologies address the
for side-to-side airflow switches. Figure 6. Data Center Facility considerations at all levels (cabinet, pod, and data
xx Thermal and cable management to provide capacity center).
for two Cisco Catalyst® 6509, MDS 9513, or Nexus Computational fluid dynamics (CFD) testing was
7010 switches. ­performed to ensure that each Cisco and Panduit
xx Copper/fiber cable management to ensure optimal ­infrastructure topology scales within the bounds of a
bend radius and access to vertical pathways. typical data center’s facility limitations (Figure 5 and 6).
xx Fully integrated electrically bonded structure to ensure
protection for active equipment. Data Center Standards
Figure 3. Modular Pod Topology Industry standards must be taken into consideration
throughout the entire design process. Data center
­standards to consider include:

xx TIA-942: Telecommunications Infrastructure Standard


Figure 7. Flovent Model
for Data Centers
xx ASHRAE: Thermal Guidelines
xx IEEE 1100: Power and Grounding Standards
xx OSHA: Safety Standards
Cisco and Panduit topologies include these network,
thermal, power, and safety standards to help take the
Figure 4. Vertical Patching Figure 5. Hot Spot Analysis guesswork out of compliance.

Summary
Cisco-Panduit data center infrastructure topologies
provide enterprise customers with a series of templates
to quickly deploy robust, flexible, and scalable data
Using Panduit connectivity solutions within a combined center architectures to maximize return on technology
Cisco-Panduit infrastructure pod topology helps ensure: investment.

xx Proper scaling of power requirements.


xx Proper cabinet and data center thermal management. For more information, see:
Populated cabinets and racks can be consolidated into xx www.cisco.com/go/datacenter
xx Efficient use of data center footprint.
a pod topology. Figure 3 shows an example of a modular xx www.panduit.com/datacenter
xx Scalability for future growth.
pod topology.