You are on page 1of 2
srreet Créfierers wiciierst ferfBes aye BHARAT PETROLEUM CORPORATION LTD. Saree Hea a SET AGovt of nda Enterprise LPG EQ 11; 22.02.16 Mis. Agrasen Steel Tubes Pvt.Lid.,Patancheru ‘Survey No..- 203, House No.-4-59/1, Pati Village, Patancheru Mandal Medak Dist - 500124, Sir, 7 REVOCATION OF SUSPENSION ON BPC's ACCOUNT Please refer to HPC’s letter reference LPGITA/PK dated 03.12.15 advising you to suspend production and, dispatch of LPG cylinders, based on FOUR new cylinder of 14.2 kg bearing Sr. No. 010838, 010055,010733 & 010581, batch No. HE-014 & test date 11/15 were found leeking from the bung weld joint, during fst fil at HPC's Madurai LPG Plant, We note that you vide your letter Ref. ASTPL/HPCL/15-16 dated 21.01.16 informed OMCs, about the following corrective measures to prevent the recurrence of such defects in future, 1. Instalaton of bifing machine before bung welding stage, to ensure proper cleaning of edges, bur, el. ofthe bung welding area, 2. Replacement of transformer of welding machine to avoid fluctuation of voltagefourrent & also re- calibration of voltmeter, ammeter. Changing and re-servicing of bung welding fixtures. Additional lighting on bung welding machine for better visibility. 7 In house refresher training program for quality control inspectors and welders. Replacement of gas flow meter of bung welding machines, to ensure proper flow of gas. one Additonal, the party vide ther leter ref. ASTPLINPCLI201S-16/Revocation of suspension dated 04.02.2016 has also confirmed about undertaking following measures 41. Dispatch of all the ready cylinders at their plant, only after repeat hydro-esting and pneumatic testing and overall visual inspection.“ 2. Replacement of power source of bung welding machine. 3. Demarcation of specific areas for sloring any re-works| rejected cylinders. Please note that all the records pertaining to corrective actions should be maintained and made available to Inspections / Technical audits as and when required. You must ensure the implementation of the above in totality. However, we would lke to emphasize that your manufacturing and inspection processes should be reviewed consistently . exercising stringent intemal controls to ensure quality of the LPG cylinders as per applicable standards. ae 9 ooo eat, ee ae AE, eee Fel A), ed 400018, Sr: B15 TEA, 24117850 fo 2417 TEAS re he we, 48.6, mts, tnd BU, hee We 88, Had 400001, TPG Expert Doparinent 2nd Fer, erro Bost, N aalatn, Seno Eas, Murs 400 O78 Phone 2411748, 241 Tas0, Fax ATI TOG Registered Oe: Brat Bhovan, 4&8, Curimbhoy Rod, Ballard Etat, PB. Noe, Mumbai - 40007, CAELZ3Z20H eSICOIIORS' Further, you are cautioned you that in case of any such lapses observed on your part, we shall be constrained to take stingent actions against you as deemed fit View above, we hereby revoke the suspension of production and despatch of LPG cylinders on BPC’s account with immediate effect. Thanking you, Yours faithfully, For BHARAT PETROLEUM CORPORATION LTD., Chief LPG Equipment Manager Cc: CCOE, Nagpur : BIS, New Delhi BIS, Hyderabad 1OC, Mumbai - Attn: Mr. Ashutosh Tiwari HPC, Mumbai - Attn: Mr.P.N.Kanth, 50 PITS X 500, Aug. 2014 (RF)

You might also like