Professional Documents
Culture Documents
4 José Matias - Reactive Power Compensation PDF
4 José Matias - Reactive Power Compensation PDF
Benefits
Reduces harmonic content in the network
which further reduces disturbances in
telecommunication network, misbehavior in
control equipments and relay protections,
measuring errors in metering system
Current waveform Current waveform
before after Reduces network losses
harmonic filtering harmonic filtering
Reduces equipment overloading & stress on
Harmonic filtering implies mitigating insulation
harmonic currents generated by the non- Reduces cost and generates higher revenue
linear loads like rectifiers, drives, furnaces, for the customer
welding machines, converters, HF lamps,
electronic equipments etc in the network. Reduces unplanned outages and increases
power availability
Reactive Power
Compensation/Harmonic Filter
S
Q
Reactive power need/ demand
Reactive power
compensation
(supplied from network)
(supplied by
capacitors)
Q’ S
Reduced reactive
power need/ demand
(supplied by
’ network)
P
Active power Available
active power
© ABB Group
June 19, 2013 | Slide 8
Reactive power
Implementing the compensation in the network
1020 kvar
1425kVA
1425 kVA
(95% loading AC 470 kvar
factor)
Supply
~1100kVA
(74% loading
factor)
1500kVA Transformer 1500kVA Transformer
Recovered Capacity Recovered Capacity
= 0kVA (0%) = 325 kVA (22 %)
Power triangle of an installation running at low Power triangle of the same installation where
cos and for which the transformer is close to power factor correction has been applied
full load reduces load on the transformer / releases
capacity for additional loads
© ABB High Voltage Products
June 19, 2013 | Slide 10
Reactive Power Compensation
Added value: optimizing power availability
M 60 MW M 60 MW
10 kV Compensation
10 kV
Example
0.15 x 60 MW = 9 Mvar
S1
Q1
Compensation S2
φ1 Q2
φ2
P = 60 MW P = 60 MW
© ABB High Voltage Products
June 19, 2013 | Slide 11
Reactive Power Compensation
Advantages: Summary/Conclusion
Qfree = X % x P according to tariff/utility regulation Max. Qfree allowed from utility= 0,15 * 60 = 9 Mvar
Q Before After
Q1
REACTIVE POWER
Beer: Foam
Electricity - Unable to do work
APPARENT POWER
Beer: Full glass
Electricity - Available from utility
REAL POWER
Beer: Drinkable
Electricity = Able to do work
h
Capacitance
w d
U-
• Area of the plates = w x d
• Distance between the plates (thickness of the dielectric)
• Permittivity of the insulating material (dielectric) or Dielectric constant
Reactive Power
• Capacitance
• Voltage
• Frequency
© ABB High Voltage Products
June 19, 2013 | Slide 16
ABB’s unique features
Reliable and well utilized capacitor elements
50
© ABB Group
June 19, 2013 | Slide 18
Reliability
ABB Capacitors: Failure rates examples
© ABB Group
June 19, 2013 | Slide 19
Power Factor Compensation & Filter Solutions
Basic definitions: Capacitor unit components
Bushing
Elements
Internal fuse
Discharge resistor
Internal insulation
Can
(stainless steel)
Stacked
Elements
Capacitor
Units
Insulators Unbalance CT
© ABB High Voltage Products
June 19, 2013 | Slide 24
Power Factor Compensation & Filter Solutions
Harmonic Filters: Core components
Capacitors C
C [µF]
Reactors
L [mH]
R
Resistance L
R [Ω]
For filter
performance these
values are the Design voltages and currents come out of these, based
important on the system calculations.
© ABB High Voltage Products
June 19, 2013 | Slide 25
Power Factor Compensation
ABB Capacitors
History and background
© ABB High Voltage Products
June 19, 2013 | Slide 26
ABB Capacitors
ABB Production Facilities & Technical Centers
Ludvika
Quebec TLC HV
PQC & LAU HV Capacitor factory
Youngwood, PA Bulgaria
LAU
Xian
LAU Jumet HV
TLC LV Capacitor factory
Galindo Bangkok
PQC & LAU LV
Guarulhos Bangalore
PQC & LAU HV
Number of HV/MV factories: 4 Capacitor factory
Number of LV factories: 2
Johannesburg Lilydale
Local assembly units: 5 LAU
HV Capacitor factory
Sales Office in 100 countries
750
500
250
V o lts
0
-25 0
-50 0
-75 0
300 0
200 0
100 0
A m ps
-10 00
-20 00
-30 00
10: 25:43 .72 10: 25:43 .73 10: 25:43 .74 10: 25:43 .75 10: 25:43 .76 10: 25:43 .77 10: 25:43 .78
C H A Vol ts C H B Vol ts C H C Vo lts C H A Am p s C H B Am p s C H C Am p s
Voltage: THDV = 12% W a vefo rm ev en t a t 22/1 1/01 10:25 :43.5 33 Current: THDI = 27%
Type: EMPAC
Enclosed switched MV Capacitor Bank
One enclosure = One step
Voltage range: Max. 36 kV
Up-to 24 kV – 1 level: 7.2 Mvar
Power & Voltage range
Up-to 24 kV – 2 levels: 10.8 Mvar
in one single step;
24 to 36 kV – 2 levels: 14.4 Mvar
Switching: Yes (Optional)
Protection degree IP 44
Capacitors units equipped with internal fuse
Capacitor units:
and discharging resistor.
Connection: Double star
Installation Indoor or Outdoor
Temperature range: -25 to +40 ̊C
Delivered with all internal electrical wiring between capacitors;
CT and reactors (if included) are pre-connected/factory assembled
Type: SIKAP
Enclosed MV non-switched capacitor bank
One enclosure = One step
Voltage Range: 4.5 - 24 kV
Power Range: Up to 18 Mvar
Switching: No
Protection degree: IP44
Capacitors units equipped with internal fuse and
Capacitor units:
discharging resistor.
Connection Single or Double Star
Installation: Indoor/Outdoor
Temperature range: -40 to +40 ̊C
Origin: Sweden
Delivered with all internal electrical wiring between capacitors, CT and
reactors (if included) pre-connected/factory assembled
Voltage Up to 36 kV Up to 36 kV Up to 24 kV Up to 36 kV Up to 800 kV
Max. total reactive 20 Mvar 14.4 Mvar 18 Mvar 3.6 Mvar Undefined
power @50 Hz (limited by design)
IP 65 44 44 00 00
Temperature range -50 to +55 ̊C -25 to +40 ̊C -40 to +40 ̊C -50 to +55 ̊C -50 to +55 ̊C
Applicable standards IEC 60871-1, IEC 60871-4, IEEE 18, Others on request
1) Mostly for detunned filtering, in order to prevent resonance issues. Small tunned filters can also be used, mostly with filter buliding blocks (reactors and resistors)
installed separated and not in the enclosure.
2) Can be used for tunned filters with filter buliding blocks (reactors and resistors) installed separated and not in the enclosure.
Protection
Unbalance (1) (1) (1)
Switching Contactors & switches (1 per step) (1 per bank) (1 per bank) For HV only
Circuit breaker & accessories (1 per step) (1 per bank)
MV fuse-link protection
Earthing switch
Reactors Inrush
Detuned
Filter (1) (1) (1)
Instrument Unbalanace CT
Transformers
Protection CTs
Protection VTs
Rapid-discharge VT’s
(1) Supplied loose and installed separately
© ABB High Voltage Products
June 19, 2013 | Slide 40
ABB MV & HV Capacitors Portfolio
Pole-mounted MV capacitor bank
Type: Q-POLE
Pole mounted capacitor bank
Voltage Range: Up to 36 kV
Switching: Yes
Installation: Outdoor
Temperature range: -50 to +55 ̊C
Delivered with all electrical wiring between capacitors; Controller, CS, PT
and reactors (if included) are pre-connected/factory assembled
QBANK-A QBANK-B
QBANK-C
Slide 1
ABB MV & HV Capacitors Portfolio
Harmonic filters type CHARM
Type: CHARM
Tuned or detuned design:
Tuned filters: Suitable when source of harmonics, and
harmonic content is well defined
De-tuned filters: Suitable when harmonics originate from
many sources, and many harmonic frequencies are present
SVC
220 kV
Typical application is fast changing loads
TCR 5: a 7: o 11: e
135 Mvar 51 Mvar 29 Mvar 10 Mvar
Surge capacitor The primary function of the Type MSP motor surge
1 phase or 3 phases protector is to guard the winding insulation of the
device being protected.
Magnetic actuator
Maintenance free
Hydrophobic ‘cycloaliphatic’ epoxy (HCEP) resin
insulator
CQ900 Range
User friendly interface
Data logging
Protection
Switchsync Range
Controlled switching of the capacitor bank breaker
gives efficient reduction of the switching transients
Energizing of capacitor banks and harmonic filters may cause severe inrush currents and voltage oscillations
Download from
abb.com/highvoltage