You are on page 1of 28

Global Presence for

Peace of Mind

Direct and Indirect Acting Solenoid Valves


Models FP03P, FP06P, FP10P, FP12P,
SJ06, S06, S09, S12 & SPR

Superior Performance Throughout the Full Operational Range

Solenoid Valve Worldwide Solenoid Approvals


SIL 3 Third Party Certified Ex d, Ex ia, Ex emb, explosion proof
Solenoid Free to Rotate ATEX Registered

Through 360º
Low Power
316L Stainless Steel Solenoid
Housing and Valve High Flow

Arctic Service Options to -60ºC Up to 35 bar Working Pressure

Innovative and Reliable


www.bifold.co.uk
Valve Solutions
Solenoid Valve Range

Features & Benefits


Worldwide Approvals

Standard Solenoids

ATEX Equipment Design & Build

Worldwide Approval
Registered

Solenoid Operator is Free to Rotate 360º Solenoid operator and mounting block (patent
pending) are free to rotate 360º allowing for an easy
cable layout and ease of connection wiring. Solenoid
internals rotate with operator and prevent cables
being pulled out of terminal block.

Widest range of override options (Auto Reset,


Spring Return Manual Override, Stayput Manual
Override, Manual Reset, Tamperproof Manual Latch,
Latch Energised).
Widest Range of Override Options

Worldwide technical and field support.

Standard solenoid valve can be mounted in any


orientation to simplify installation due to all the
components having enhanced rotational capabilities.
Valve can be Mounted in any Orientation
Commissioning and Maintenance Benefits for
the Standard Solenoid

Tropicalised solenoid design - all 316L stainless steel


construction including magnetic parts. Fully
encapsulated coil.
Spacious Enclosure for Ease of Wiring

Spacious solenoid enclosure for ease of wiring.

No time penalty for heat dissipation before


removing solenoid cover.

No special high temperature cable requirements.

Internal Earth Surge Suppression Terminal Block


Connection Diode Ex d (dc)

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
2 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Features & Benefits


Worldwide Approvals

Slimline Solenoids

ATEX Equipment Design & Build

Registered
Worldwide Approvals.

Solenoid Operator is Free to Rotate 360º Solenoid operator is free to rotate 360º allowing for
an easy cable layout and ease of connection wiring.
Solenoid internals rotate with operator and prevent
cables being pulled out of terminal block.

Carbon steel solenoid operator, coated for offshore


applications as well as a 316L stainless steel solenoid
housing option.

Override Options Override Options - Auto Reset, Manual Override and


Manual Reset.

Worldwide technical and field support.

Solenoid valve can be mounted in any orientation to


simplify installation.
Valve Assembly can be Mounted in any
Orientation
Commissioning and Maintenance Benefits for the
Slimline Solenoids

Tropicalised solenoid design - Fully encapsulated coil.

Compact Enclosure Design No time penalty for heat dissipation before removing
solenoid cover.

No special high temperature cable requirements.

Compact design and space envelope.

Coil Leads

Incoming Supply Leads Terminal Block


Connect +Ve To Red Coil Lead Surge Suppression
Connect –Ve To Black Coil Diode Ex d (dc)

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
3
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Valve Range

Features & Benefits


SIL certified, FMEA, extensive qualification testing coupled with 100% Computerised Diagnostic Test
Procedures.

Safety and Environmental Benefits

Standard solenoid operator has SIL third party certification to


IEC 61508, FMEA, extensive qualification testing.

Balanced valve with high safety factors to de-energise


at all pressures in Normally Open and Normally
Closed configurations.

100% computerised diagnostic testing to ensure each


solenoid valve is proven along with confirmed safety
factors.

Bifold has state of the art testing and qualification


equipment including endurance, environment, climatic,
performance, function and leakage testing.

State of the Art Testing The standard solenoid operator is a holding magnet
type which ensures the valve will operate in damp
conditions. The risk of corrosion to internal
components is reduced, unlike other valve types that
incorporate a solenoid core tube design with a
'wetted' armature that will only operate in dry air
conditions!

Tolerant to moist air in control lines.

The standard solenoid operator has proven arctic


services and low temperature performance.

Products are manufactured, inspected, assembled and


tested in our state of the art production facilities.

Large clearances, metal back up to seals and no knife


edge sealing to prevent long term valve sticking.

Dry armature to prevent armature corrosion affecting


Simple Maintenance safe shut down.

Simple maintenance - Removable transient


suppression diode and solenoid coil without removing
valve from the tubing.

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
4 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Selection Table

DIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number
1⁄8" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Closed, 24Vdc, Auto Reset.
FP03P-02-32-NC-V-74A-24D-36 ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NC IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.1, 10 bar.
15
1
ATEX II 2 GD, Ex d IIC T6
2
FP03P-02-32-NC-V-77A-24D-30 IECEx Ex d IIC T6
3
3.0 Watt, Cv 0.1, 10 bar.

FP03P ATEX II I GD, Ex ia IIC T6 Ga


FP03P-02-32-NC-V-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 0.1, 10 bar.
1⁄8" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Closed, 24Vdc, Manual Reset.
FP03P-02-32-NC-V-74A-24D-ML-36 ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NC
IECEx Ex emb IIC T3 Gb
R 3.6 Watt, Cv 0.1, 10 bar.
15
1
ATEX II 2 GD, Ex d IIC T6
2
3
FP03P-02-32-NC-V-77A-24D-ML-30 IECEx Ex d IIC T6
3.0 Watt, Cv 0.1, 10 bar.
FP03P ATEX II I GD, Ex ia IIC T6 Ga
Manual Reset
FP03P-02-32-NC-V-78A-ML-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 0.1, 10 bar.
¼" NPT Ports, 3 Way 2 Position, Direct Acting,
FP06P-S1-04-32-NU-V-74A-24D-36 Normally Universal, 24Vdc, Auto Reset.
ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NU FP06P-S1-04-32-NU-V-74A-24D-44 IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.4, 10 bar.
FP06P-S1-04-32-NU-V-74A-24D-68 4.4 Watt, Cv 0.5, 10 bar.
16
1
2 6.8 Watt, Cv 0.75, 10 bar.
3
ATEX II 2 GD, Ex d IIC T6
FP06P-S1-04-32-NU-V-77A-24D-35
IECEx Ex d IIC T6
FP06P FP06P-S1-04-32-NU-V-77A-24D-57
3.5 Watt, Cv 0.5, 10 bar.
5.7 Watt, Cv 0.75, 10 bar.

¼" NPT Ports, 3 Way 2 Position, Direct Acting,


Normally Universal, 24Vdc, Manual Reset.

SCHEMATIC 3/2 NU FP06P-S1-04-32-NU-V-74A-24D-ML-36 ATEX II 2 GDc, Ex emb IIC T3 Gb


R IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.75, 10 bar.
16
1
2
3

ATEX II 2 GD, Ex d IIC T6


FP06P FP06P-S1-04-32-NU-V-77A-24D-ML-30 IECEx Ex d IIC T6
Manual Reset 3.0 Watt, Cv 0.75, 10 bar.

† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
5
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Valve Range

Selection Table

DIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number

SCHEMATIC 3/2 NU ¼" NPT Ports, 3 Way 2 Position, Direct Acting,


Normally Universal, 24Vdc, Auto Reset.
17 FP06P-SI-04-32-NU-V-58A-135 ATEX II 1G Ex ia, IIC T6 Ga
1
2
IECEx Ex ia IIC T6 Ga
3
135 Ohms, Cv 0.5, 10 bar. †
FP06P
¼" NPT Ports, 3 Way 2 Position, Direct Acting,
FP10P-SI-04-32-NU-V-74A-24D-36 Normally Universal, 24Vdc, Auto Reset.
ATEX II 2 GDc, Ex emb IIC T3 Gb
SCHEMATIC 3/2 NU
FP10P-SI-04-32-NU-V-74A-24D-44 IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 0.4, 10 bar.
18 FP10P-SI-04-32-NU-V-74A-24D-68 4.4 Watt, Cv 0.5, 10 bar.
1
2 6.8 Watt, Cv 0.75, 10 bar.
3
ATEX II 2 GD, Ex d IIC T6
FP10P-SI-04-32-NU-V-77A-24D-35 IECEx Ex d IIC T6
FP10P 3.5 Watt, Cv 0.5, 10 bar.
FP10P-SI-04-32-NU-V-77A-24D-57
5.7 Watt, Cv 0.75, 10 bar.
¼" NPT Ports, 3 Way 2 Position, Direct Acting,
SCHEMATIC 3/2 NU
Normally Universal, 24Vdc, Manual Reset.
FP10P-SI-04-32-NU-V-74A-24D-ML-36 ATEX II 2 GDc, Ex emb IIC T3 Gb
R
IECEx Ex emb IIC T3 Gb
18 3.6 Watt, Cv 0.75, 10 bar.
1
2
3
ATEX II 2 GD, Ex d IIC T6
FP10P FP10P-SI-04-32-NU-V-77A-24D-ML-30 IECEx Ex d IIC T6
Manual Reset 3.0 Watt, Cv 0.75, 10 bar.

SCHEMATIC 3/2 NU
½" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Universal, 24Vdc, Auto Reset.
1
19 FP12P-S1-08-32-NU-V-77A-24D-120 ATEX II 2 GD, Ex d IIC T6
2
3 IECEx Ex d IIC T6
12 Watt, Cv 2.5, 10 bar.

FP12P

SCHEMATIC 3/2 NU
R ½" NPT Ports, 3 Way 2 Position, Direct Acting,
Normally Universal, 24Vdc, Manual Reset.
19 FP12P-S1-08-32-NU-V-77A-24D-ML-65
1
2 ATEX II 2 GD, Ex d IIC T6
3 IECEx Ex d IIC T6
6.5 Watt, Cv 2.5, 10 bar.
FP12P
Manual Reset

† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
6 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Selection Table

INDIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number

¼" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed, 24Vdc, Auto Reset.
SJ06-EI-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC
ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T 3.6 Watt, Cv 0.7, 10 bar.

20
3
ATEX II 2 GD, Ex d IIC T6
2 SJ06-EI-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1 3.0 Watt, Cv 0.7, 10 bar.

SJ06 ATEX II I GD, Ex ia IIC T6 Ga


SJ06-EI-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 0.7, 10 bar.

¼" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed 24Vdc, Manual Reset.
SJ06-E5-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC ATEX II 2 GDc, Ex emb IIC T3 Gb
R
IECEx Ex emb IIC T3 Gb
T
3.6 Watt, Cv 0.7, 10 bar.
20
3 ATEX II 2 GD, Ex d IIC T6
2
SJ06-E5-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 0.7, 10 bar.

SJ06
Manual Reset ATEX II I GD, Ex ia IIC T6 Ga
SJ06-E5-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga
370 Ohms, Cv 0.7, 10 bar.

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed, 24Vdc, Auto Reset.
S12-E1-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T 3.6 Watt, Cv 1.7, 10 bar.

21
3
2
ATEX II 2 GD, Ex d IIC T6
S12-E1-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
3.0 Watt, Cv 1.7, 10 bar.
1

S12
ATEX II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
S12-E1-32-NC-00-78A-370
370 Ohms, Cv 1.7, 10 bar. †

† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
7
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Valve Range

Selection Table

INDIRECT ACTING SOLENOID VALVES - PREFERRED RANGE


Schematic Page
Product Product Code Product Description
Representation Number

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Closed, 24Vdc, Manual Reset.
S12-E5-32-NC-00-74A-24D-36
SCHEMATIC 3/2 NC ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T R 3.6 Watt, Cv 1.7, 10 bar.

21
3 ATEX II 2 GD, Ex d IIC T6
2
S12-E5-32-NC-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 1.7, 10 bar.
S12
Manual Reset ATEX II I GD, Ex ia IIC T6 Ga
S12-E5-32-NC-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 1.7, 10 bar.

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Universal, 24Vdc, Auto Reset.
SPR12-E1-32-NU-00-74A-24D-36
SCHEMATIC 3/2 NU ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
3.6 Watt, Cv 3.0, 10 bar.
T

22
3 ATEX II 2 GD, Ex d IIC T6
2
SPR12-E1-32-NU-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 3.0, 10 bar.
SPR12
ATEX II I GD, Ex ia IIC T6 Ga
SPR12-E1-32-NU-00-78A-370 IECEx Ex ia IIC T6 Ga †
370 Ohms, Cv 3.0, 10 bar.

½" NPT Ports, 3 Way 2 Position, Pilot


Operated, Indirect Acting, Normally
Universal, 24Vdc, Manual Reset.
SPR12-E5-32-NU-00-74A-24D-36
SCHEMATIC 3/2 NU
ATEX II 2 GDc, Ex emb IIC T3 Gb
IECEx Ex emb IIC T3 Gb
T R 3.6 Watt, Cv 3.0, 10 bar.

22
3 ATEX II 2 GD, Ex d IIC T6
2
SPR12-E5-32-NU-00-77A-24D-30 IECEx Ex d IIC T6
1
3.0 Watt, Cv 3.0, 10 bar.
SPR12
Manual Reset
ATEX II I GD, Ex ia IIC T6 Ga
SPR12-E5-32-NU-00-78A-370 IECEx Ex ia IIC T6 Ga
370 Ohms, Cv 3.0, 10 bar. †
† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
8 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Range

Overview
Materials of Construction

Solenoid housing and valve manufactured from 316L stainless steel as standard.
Valve seals are supplied in Viton as standard. Alternative elastomers available for extreme conditions and to suit media.
Springs are manufactured from 302S26 & 316S42 stainless steel as standard.
Fasteners are metric A4 18/10 grade stainless steel; equivalent to 316L grade stainless steel.

Technical Data

Operating Performance for FP03P, FP06P, FP10P, FP12P, SJ06, S06, S09, S12 & SPR
Duty cycle 100% continuously rated/energised.
Surge suppression diode is fitted on all Ex d dc solenoid coils as standard.
Response times - pull in <100ms, drop out <70ms.
Solenoid Insulation - Class H.
Pull-in volts to 85% of nominal. (Checked at FAT to be within specified limits to guarantee safety factors).
Maximum volts at 110% of nominal.
Drop-out volts typically 10 - 20% of nominal (higher Volt options for line monitoring). (Checked at FAT to be within
specified limits to guarantee safety factors).
Temperature rating -20ºC to upper limit of solenoid classification (standard). Arctic service option to -60ºC.
IP66 & IP67 Ingress Protection to IEC 60529 and NEMA 4X.
Bifold solenoid valves must be installed, operated and maintained in accordance with the relevant Bifold installation, operating
and maintenance instructions, relevant installation rules, regulations and codes of practice.

Product Options
Certification & Approval options available Certification & Approval options available
for standard 7 series solenoid housing for slimline 5 series solenoid housing

ATEX Registered ATEX Registered

SIL 3, Safety Integrity Level, third party certification to IEC 61508 (Valve models FP03P, FP06P & FP10P. Note: FP03P fitted as
the pilot stage operator on SJ06, S06, S09, S12 & SPR).
Valves can be mounted in any orientation. Solenoids can be rotated relative to the pilot stage valve body to suit cable entry.
Working pressure up to 35 bar. Maximum working pressure according to valve model.
Operating media - Filtered lubricated or unlubricated air, inert gas, sweet (natural) and sour gas options, water,
water glycol mixtures and mineral oil. Maximum viscosity 65 cSt (mm²/s).
For operating temperature range, please see solenoid valve type and seal options.
Higher voltage options available for line monitoring.
Manual Reset, Manual Override and Manual Latch operator options.
Arctic Service options to -60ºC.
These products can be incorporated within our 'AXIS' valve actuator control manifold systems.
See catalogue 03: - AXIS Manifold System.

Typical 'AXIS' valve actuator control manifold assembly

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
9
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Certification & Approvals

Certification Details
Certification & Approval Details
Type 74 Solenoid
ATEX, Certificate Number Baseefa 09ATEX0040X. IECEx, Certificate Number IECEx Bas 09.0012X.
II 2 GD c Ex emb IIC T3 Gb Tamb -25ºC to +40ºC. Ex emb IIC T3 Gb Tamb -25ºC to +40ºC.
II 2 GD c Ex emb IIC T3 Gb Tamb -25ºC to +55ºC. Ex emb IIC T3 Gb Tamb -25ºC to +55ºC.
Dual Labelled/Marked
Type 77 Solenoid
ATEX, Certificate Number Baseefa 10ATEX0026. IECEx, Certificate Number IECEx Bas 10.0008.
II 2 GD Ex d IIC T6 (Tamb -60ºC to +40ºC). Ex d IIC T6 (Tamb -60ºC to +40ºC).
II 2 GD Ex d IIC T5 (Tamb -60ºC to +55ºC). Ex d IIC T5 (Tamb -60ºC to +55ºC).
II 2 GD Ex d IIC T4 (Tamb -60ºC to +90ºC). Ex d IIC T4 (Tamb -60ºC to +90ºC).
Dual Labelled/Marked
Type 58 Solenoid
ATEX, Certificate Number Baseefa 08ATEX0292X. IECEx, Certificate Number IECEx Bas 08.0095X.
II 1G Ex ia IIC T6 Ga (-40ºC ≤ Ta ≤ +60ºC). Ex ia IIB T6 Ga (-40ºC ≤ Ta ≤ +60ºC).
Dual Labelled/Marked
Type 78 Solenoid
ATEX, Certificate Number Baseefa 02ATEX0124X. IECEx, Certificate Number IECEx Bas 09.0092X.
II I GD Ex ia IIC T6 Ga (Tamb = -60ºC to +60ºC). Ex ia IIC T6 Ga (Tamb = -60ºC to +60ºC).
II I GD Ex ia IIC T4 Ga (Tamb = -60ºC to +95ºC). Ex ia IIC T4 Ga (Tamb = -60ºC to +95ºC).
Dual Labelled/Marked
Type 77 Solenoid Type 77 Solenoid
CSA (US), Certificate Number 1398692 ATEX, Certificate Number Baseefa 10ATEX0026.
Class 1, Division 1, Groups B, C & D for both II 2 GD Ex d IIC T6 (Tamb -60ºC to +40ºC).
Canada & USA. II 2 GD Ex d IIC T5 (Tamb -60ºC to +55ºC).
Ex d IIC for Canada, AEx d IIC for USA.
T85ºC -60ºC to +40ºC ambient. II 2 GD Ex d IIC T4 (Tamb -60ºC to +90ºC).
T100ºC -60ºC to +55ºC ambient.
T135ºC -60ºC to +90ºC ambient.
Dual Labelled/Marked
Type 58 Solenoid Type 58 Solenoid
INMETRO, Certificate Number CEPEL 12.2125X. GOST, Certificate Number B0015, RTN Permit
BR-Ex ia IIB T6 -40ºC to +60ºC ambient. Number PPC 00-048112
0Ex ia IIC T6 -40ºC to +40ºC ambient.
Type 77 Solenoid 0Ex ia IIC T5 -40ºC to +55ºC ambient.
INMETRO, Certificate Number CEPEL-EX-097/2003X. 0Ex ia IIC T4 -40ºC to +60ºC ambient.
BR-Ex d IIC T6 -60ºC to +40ºC ambient. Type 77 Solenoid
BR-Ex d IIC T5 -60ºC to +55ºC ambient. GOST, Certificate Number B00763, RTN.
BR-Ex d IIC T4 -60ºC to +90ºC ambient. Ex d IIC T6 -60ºC to +40ºC ambient.
Ex d IIC T5 -60ºC to +55ºC ambient.
Type 78 Solenoid Ex d IIC T4 -60ºC to +90ºC ambient.
INMETRO, Certificate Number CEPEL-EX-532/05.
Type 78 Solenoid
BR-Ex ia IIC T6 -60ºC to + 40ºC ambient.
GOST, Certificate Number B00015, RTN.
BR-Ex ia IIC T4 -60ºC to + 95ºC ambient.
Permit Number PPC 00-28504.
Ex ia IIC T6 -60ºC to +40ºC ambient.
Type 87 Solenoid Ex ia IIC T5 -60ºC to +55ºC ambient.
NEPSI, Certificate Number GYJ081011. Ex ia IIC T4 -60ºC to +90ºC ambient.
Ex d IIC T6 up to 40ºC ambient. Type 77 & 78 Solenoid
Ex d IIC T5 up to 55ºC ambient.
Ex d IIC T4 up to 95ºC ambient. GOST K, GGTN K Permit, Kazakhstan,
BIF 7727 2.
Label Rationalisation
The temperature details on our solenoid labels have, to date, been These are in the process of being replaced with a single label which
laid out with a single ambient range and 'T' rating, as follows :- covers all potential temperature parameters.Therefore the label
will for example, read as follows :-

{
77A3 - T4 (-60ºC ≤ Tamb ≤ +90ºC) T4 (-60ºC ≤ Tamb ≤ +90ºC) {
or 77A6 - T5 (-60ºC ≤ Tamb ≤ +55ºC) 77A T5 (-60ºC ≤ Tamb ≤ +55ºC)
or 77A9 - T6 (-60ºC ≤ Tamb ≤ +40ºC) T6 (-60ºC ≤ Tamb ≤ +40ºC)
Please note that operation ambients are dependant upon seal types.
For solenoid type 87 please note that the solenoid housing is fixed.
For solenoid type 74 the maximum permissible ambient temperature is subject to the coil wattage. Please see page 12.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
10 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Valve Product Options

Port Connections
Port Connections for
Port Connections (FP03P Only) (FP06P, FP10P, FP12P, SJ06, S06, S09, S12 & SPR)
PORT CONNECTIONS TABLE PORT CONNECTIONS TABLE
Configuration Pressure Service Vent Configuration Pressure Service Vent

Normally Closed 1 2 3 Normally Closed 1 2 3


For port connections please refer to selection chart ordering Normally Open 3 2 1
example. Page 15 Selector 1&3 2 N/A
Diverter 2 1&3 N/A
Product Weights For port connections please refer to selection chart ordering
example. Pages 16, 17, 18, 19, 20, 21 & 22
Approximate Standard Product Weights
PRODUCT WEIGHTS Seal Repair Kit
Product Approximate Weight (Kg) Seal Repair Kit Selection Chart - Ordering Example
(FP03P, FP06P, FP10P & FP12P)
FP03P 1.75 Seal Repair Kit
SRK
FP06P 2.1 FP03P
FP10P 2.5 FP06P
FP10P Model Code
FP12P 3.0 FP12P
SJ06 2.7 S Nitrile (-20ºC to +130ºC)
S06/S09/S12 3.4 V Viton (Standard) (-20ºC to +180ºC)
AG Silicone (-60ºC to +180ºC) O-ring Material
SPR 3.2 AL Fluorosilicone (-60ºC to +180ºC)

Solenoid Coil Spare Ordering Example


SRK FP06P V
Solenoid Coil Spare Selection Chart For SJ06, S06/S09/S12 & SPR, please contact Bifold Sales Department.
Ordering Example Type 74 & 77
109
XXX Voltage 74 (Ex emb) 24 & 48 Vdc
Coil Type Solenoid Coil Spare
77 (Ex d) 12,24,48 &110 Vdc Voltage
77 (Ex d) 110 & 240Vac Solenoid Coil Spare Selection Chart
XX Power (W) 74 (Ex emb) 1.8,3.6,4.4 & 6.8Watts
Power Ordering Example Type 58
77 (Ex d) 3.0,3.5,5.7 & 12Watts
58 Coil Type
XX Resistance (Ω) 58 (Ex ia) 370 Ohms Resistance

109 24DC 30 Ordering Example


For solenoid operator Type 77 (Ex d) Vac, the coil
spare ordering example is shown below:- 58 370 Ordering Example
109 110AC 57
For more information, please contact Bifold Sales Department.

Solenoid Coil Spare


Solenoid Coil Spare Selection Chart
Ordering Example Type 78
109 Coil Type
XXX Nominal Voltage 78 (Ex ia) 12 Nominal Voltage
XX Resistance (Ω) 78 (Ex ia) 370 Ohms Resistance

109 12 370 Ordering Example

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
11
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Options

Ex emb Options
Options Table 1 74 (Ex emb)
SOLENOID OPTIONS TABLE 1 74 (Ex emb)
Solenoid Typical Power Cable
Product Standard CV Temperature Ingress
Order Apparatus Consumption Entry Certification Options
Type Voltage Rate Range (ºC) Protection
Code Code (W) Connection
Media #
-20ºC to +40ºC
-25ºC to +40ºC
-20ºC to +55ºC
1.8 -25ºC to +55ºC
24 Vdc IP66 M20 x 1.5
Ex emb II Ambient
74 0.1 -25ºC to +40ºC (T3) IP67 (½" NPT ATEX IECEx
T3 -25ºC to +55ºC (T3) NEMA 4X Option)
48 Vdc Media #
-20ºC to +40ºC
3.6 -25ºC to +40ºC
FP03P Ambient
-25ºC to +40ºC (T3)

3.6 0.4
24 Vdc Media #
-20ºC to +40ºC IP66 M20 x 1.5
4.4 0.5 -25ºC to +40ºC IP67 (½" NPT ATEX IECEx
Ambient NEMA 4X Option)
48 Vdc -25ºC to +40ºC (T3)
Ex emb II 6.8 0.75
FP06P
74 T3
3.6 0.4 Media #
24 Vdc -20ºC to +40ºC M20 x 1.5
IP66
-25ºC to +40ºC (½" NPT
4.4 0.5 IP67 ATEX IECEx
Ambient NEMA 4X Option)
48 Vdc -25ºC to +40ºC (T3)
6.8 0.75
FP10P
Media #
-20ºC to +40ºC
-25ºC to +40ºC
1.8 -20ºC to +55ºC
0.7 -25ºC to +55ºC
24 Vdc Ambient IP66 M20 x 1.5
-25ºC to +40ºC (T3) IP67 (½" NPT
-25ºC to +55ºC (T3) ATEX IECEx
Media # NEMA 4X Option)
48 Vdc
-20ºC to +40ºC
3.6 0.7 -25ºC to +40ºC
SJ06 Ambient
Ex emb II -25ºC to +40ºC (T3)
74 T3 Media #
-20ºC to +40ºC
1.0 (S06) -25ºC to +40ºC
1.8 -20ºC to +55ºC
1.7 (S09) -25ºC to +55ºC
24 Vdc Ambient M20 x 1.5
1.7 (S12) IP66
-25ºC to +40ºC (T3) IP67 (½" NPT ATEX IECEx
-25ºC to +55ºC (T3)
NEMA 4X Option)
48 Vdc 1.0 (S06) Media #
-20ºC to +40ºC
3.6 1.7 (S09) -25ºC to +40ºC
S06, S09 & S12 Ambient
1.7 (S12) -25ºC to +40ºC (T3)
Media #
-20ºC to +40ºC
-25ºC to +40ºC
-20ºC to +55ºC
1.8 3.0 -25ºC to +55ºC
24 Vdc
Ex emb II Ambient
74 -25ºC to +40ºC (T3) IP66 M20 x 1.5
T3 -25ºC to +55ºC (T3)
IP67 (½" NPT ATEX IECEx
48 Vdc
NEMA 4X Option)
SPR Media #
3.0 -20ºC to +40ºC
3.6 -25ºC to +40ºC
Ambient
-25ºC to +40ºC (T3)

For detailed information on certification please see page 10.


Other Wattages available upon request.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
12 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Solenoid Options

Ex d Options
Options Table 2 77 (Ex d)
SOLENOID OPTIONS TABLE 2 77 (Ex d)
Solenoid Typical Power Temperature Cable
Product Standard CV Ingress
Order Apparatus Consumption Range (ºC) Entry Certification Options
Type Voltage Rate Protection
Code * Code (W) Media Ambient Connection
12 Vdc ATEX IECEx
Media #
24 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
48 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ex d IIC 110 Vdc
77 0.1 IP67 (½" NPT GOST K GGTN
T6, T5 Ambient
Option)
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4)
*
FP03P PESO
12 Vdc Media # ATEX IECEx
24 Vdc 3.5 0.5 -20ºC to +90ºC (T4) INMETRO
48 Vdc -60ºC to +90ºC (T4) GOST
110 Vdc IP66 M20 x 1.5
Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 5.7 0.75 -60ºC to +55ºC (T5)
Ex d IIC * NEPSI
FP06P 50 or 60 Hz -60ºC to +90ºC (T4)
77 T6, T5 PESO
or T4 ATEX IECEx
24 Vdc Media #
48 Vdc 3.5 0.5 -20ºC to +90ºC (T4) INMETRO
110Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 5.7 0.75 -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
FP10P PESO

24 Vdc Media # ATEX IECEx


48 Vdc -20ºC to +90ºC (T4) INMETRO
Ex d IIC 110Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
77 T6, T5 12 2.5 Ambient IP67 (½" NPT GOST K GGTN
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
FP12P PESO

24 Vdc Media # ATEX IECEx


48 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
110 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
0.7 Ambient IP67 (½" NPT GOST K GGTN
110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5)
* NEPSI
Ex d IIC 50 or 60 Hz -60ºC to +90ºC (T4)
SJ06 PESO
77 T6, T5
or T4 1.0 (S06) Media ATEX IECEx
24 Vdc #
48 Vdc 1.5 ~ 1.7 (S09) -20ºC to +90ºC (T4) INMETRO
110 Vdc 1.7 (S12) -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
Ambient IP67 (½" NPT GOST K GGTN
110 Vac 1.0 (S06) -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 3.0 1.7 (S09) -60ºC to +55ºC (T5) NEPSI
50 or 60 Hz -60ºC to +90ºC (T4) *
S06, S09 & S12 1.7 (S12) PESO

24 Vdc Media # ATEX IECEx


48 Vdc 1.5 ~ -20ºC to +90ºC (T4) INMETRO
Ex d IIC 110 Vdc -60ºC to +90ºC (T4) IP66 M20 x 1.5 GOST
77 T6, T5 3.0 Ambient IP67 (½" NPT GOST K GGTN
or T4 110 Vac -60ºC to +40ºC (T6) NEMA 4X Option) CSA (C, US)
240 Vac 3.0 -60ºC to +55ºC (T5)
SPR 50 or 60 Hz -60ºC to +90ºC (T4) * NEPSI
PESO

For detailed information on certification please see page 10. * For China (NEPSI), please note that the solenoid operator is Type 87.
Other wattages available upon request. ~ Non standard low power option.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
13
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Solenoid Options

Ex ia Options
Options Table 3 58 & 78 (Ex ia)

SOLENOID OPTIONS TABLE 3 58 & 78 (Ex ia)

Solenoid
Typical Cable
Product Order CV Temperature Ingress
Apparatus Entry Certification Options
Type Code Rate Range Protection
Code Connection

Media #
-20ºC to +95ºC
-60ºC to +95ºC ATEX IECEx
Ex ia IIC IP66 M20 x 1.5 INMETRO
58 † 0.5
T6 Ambient GOST
-40ºC to +60ºC
FP06P

Media #
-20ºC to +95ºC
IP66 M20 x 1.5 ATEX IECEx
-60ºC to +95ºC
Ex ia IIC IP67 (½" NPT INMETRO
78 † T6 or T4 0.1 Ambient NEMA 4X Option) GOST
-60ºC to +60ºC (T6) GOST K GGTN
-60ºC to +95ºC (T4)
FP03P

Media #
-20ºC to +95ºC ATEX IECEx
-60ºC to +95ºC IP66 M20 x 1.5 INMETRO
78 † Ex ia IIC IP67 (½" NPT
0.7 GOST
T6 or T4 Ambient NEMA 4X Option)
GOST K GGTN
-60ºC to +60ºC (T6)
-60ºC to +95ºC (T4)
SJ06

Media #
-20ºC to +95ºC ATEX IECEx
1.0 (S06) -60ºC to +95ºC IP66 M20 x 1.5
Ex ia IIC INMETRO
78 † 1.7 (S09) IP67 (½" NPT
T6 or T4 Ambient GOST
NEMA 4X Option)
1.7 (S12) -60ºC to +60ºC (T6) GOST K GGTN
-60ºC to +95ºC (T4)
S06, S09 & S12

Media #
-20ºC to +95ºC ATEX IECEx
IP66 M20 x 1.5
Ex ia IIC -60ºC to +95ºC INMETRO
3.0 IP67 (½" NPT
78 † T6 or T4 GOST
Ambient NEMA 4X Option)
GOST K GGTN
-60ºC to +60ºC (T6)
SPR -60ºC to +95ºC (T4)

For detailed information on certification please see page 10.


† Solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
# Permissible media operating temperatures are dependent upon the selected O-Ring material. Please refer to the product selection charts on pages 15 to 22.

Safety Parameters:Type 58 Safety Parameters:Type 78


Ui = 35V dc, Ii = 600 mA, Pi = 3 W, Ci = 0 μF, Li = 0 mH Ui = 31 V, Ii = 210 mA, Pi = 1.5 W, Ci = 0 μF, Li = 0 mH
Coil Resistance : 135 Ohm ± 5% Coil Resistance : 370 Ohm ± 5%
Minimum Current @ solenoid coil = 80 mA Minimum Current @ solenoid coil = 32 mA
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
14 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
FP03P Selection Chart

FP03P
Dimensional Drawing
68 86.5 SCHEMATIC 3/2 NC Wiring Diagrams
34 50 74 SOLENOID
(EExemb)
TYPE ‘M’ RED +
OVERRIDE

WINDING
OPTION 1
2
BLACK -
3

WINDING

SCHEMATIC 2/2 NC
M20 x 1.5P SOLENOID
CASE
CABLE ENTRY
180.1

AC VOLTAGE
155.4

EXTERNAL 77 SOLENOID
EARTH STUD (EExd)
1
124.6

2
CONNECTIONS AREBI-POLAR

3 WINDING
SOLENOID
CASE
1

50.5
MOUNTING POSITIONS RED + BLACK -
2 x Ø5.5 THRO' HOLES 2
37.1

26.2
DC VOLTAGE
3
25

13.8 Plug port 3 for 2/2


14

78 SOLENOID
= =
Normally Closed (EExia)
28 5 function. (Plugs
RED +
38.1 q available as a line
item). BLACK -

FP03P Selection Chart - Ordering Example


FP03P Model Code
M1 Manifold mount - For use with Axis Manifold System Only
M7 Manifold mount stacker - For use with Axis Manifold System Only Connections
02 1⁄8" NPT body ported - Shown above
32 3-way, 2-position
Valve Configuration
NC Normally Closed
V Viton (Standard) (-20ºC to +180ºC) For maximum operating temperatures
see 'T' Rating Limitations for Ex emb, O-ring Material
AL Flurosilicone (-60ºC to +180ºC) Ex d & Ex ia on pages 12, 13 & 14.
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **

74(Ex emb) 77(Ex d) 78(Ex ia)


A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer to 74 (Ex emb) Page 12 - Table 1
Solenoid option 77 (Ex d) Page 13 - Table 2 Voltage
tables. 78 (Ex ia) Page 14 - Table 3
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary Options
manual override (3.0 Watts Ex d Only)
MLT Electrical and manual required to latch - tamperproof
XX Power (W) 74 (Ex emb)- 1.8 & 3.6 Watts Page 12 - Table 1
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2 Power
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP Ports Option
K85 ½" NPT cable entry Option

FP03P 02 32 NC V 77 A 24D ML 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
15
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
FP06P Selection Chart

FP06P
Dimensional Drawing
68 86.5 SCHEMATIC 3/2 NU
34 50

TYPE ‘M’ NU Normally


OVERRIDE
OPTION
1
Universal offered
2 as standard.
3

SCHEMATIC 2/2 NC
M20 x 1.5P Valve suitable for
CABLE ENTRY
Universal operation
2/2 & 3/2.
191

1
166.5

EXTERNAL 2 Normally Open and


EARTH STUD
Normally Closed.
135.6

3
Plug port 3 for 2/2
1
Normally Closed
SCHEMATIC 2/2 NO function. (Plugs
MOUNTING POSITIONS
61.5

2 x Ø5.5 THRO' HOLES 2 available as a line


46.5

3
item).
33.5

33.5
22

17.5

Plug port 1 for 2/2


= =
1 Normally Open
2
25.4 32 6.2
function. (Plugs
3
44.45
available as a line
item).

FP06P Selection Chart - Ordering Example


FP06P Model Code
S1 10 bar maximum valve pressure
Operator
S2 16 bar maximum valve pressure (For AC Coils = 6.5 Watts)
04 ¼" NPT body ported Connections
32 3-way, 2-position
NU Normally Universal Valve Configuration
S Nitrile (-20ºC to +130ºC)
For maximum operating temperatures
V Viton (Standard) (-20ºC to +180ºC)
see 'T' Rating Limitations for Ex emb O-ring Material
AG Silicone (-60ºC to +180ºC)
& Ex d on pages 12 & 13.
AL Fluorosilicone (-60ºC to +180ºC)
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
Solenoid *
77 (Ex d) Page 13 - Table 2 **
74(Ex emb) 77(Ex d)
A ATEX/IECEx Dual Certified/Labelled  
G GOST x  Solenoid Approval
I INMETRO x 
N NEPSI* x 
U CSA (US) ATEX Dual Certified/Labelled x 
XXX Voltage, refer
74 (Ex emb) Page 12 - Table 1
to Solenoid Voltage
77 (Ex d) Page 13 - Table 2
option tables.
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary
manual override (3.0 Watts Ex d Only) Options
MLT Electrical and manual required to latch - tamperproof
LE Latched Energised (NO/NC Only) (6.5 Watts Ex d Only)
XX Power (W) 74 (Ex emb) - 3.6, 4.4 & 6.8 Watts Page 12 - Table 1
Power
77 (Ex d) - 3.5 & 5.7 Watts Page 13 - Table 2
K6 BSPP Ports Option
K85 ½" NPT cable entry Option

FP06P S2 04 32 NU V 77 A 24D ML 35 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12 or 13.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
16 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
FP06P Selection Chart

FP06P
Dimensional Drawing

FULLY ROTATIONAL SOLENOID HOUSING 72.5 50


M20 x 1.5p CONDUIT ENTRY STD.
1/2” NPT OPTION (K85)

SCHEMATIC 3/2 NU

NU Normally
Universal offered

187.5
1
2 as standard.
3
MOUNTING HOLES Ø5,5 THRO'
PORT 1
PORT 2
46.5

PORT 3
33.5

33.5
17.5
22

16 25.4
32

FP06P Selection Chart - Ordering Example


FP06P Model Code
S1 10 bar maximum valve pressure Operator
04 ¼" NPT body ported Connections
32 3-way, 2-position
NU Normally Universal Valve Configuration
S Nitrile (-20ºC to +130ºC)
For maximum operating temperatures
V Viton (Standard) (-20ºC to +180ºC)
see 'T' Rating Limitations for Ex ia on O-ring Material
AG Silicone (-60ºC to +180ºC)
page 14.
AL Fluorosilicone (-60ºC to +180ºC)
XX Refer to Solenoid options tables. 58 (Ex ia) Page 14 - Table 3 Solenoid

58(Ex ia)
A ATEX/IECEx Dual Certified/Labelled
G GOST

I INMETRO
 Solenoid Approval

N NEPSI x
U CSA (US) ATEX Dual Certified/Labelled x
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary Options

XX Resistance (Ω) 135 Ohms - 58 (Ex ia) Page 14 - Table 3 Resistance


K6 BSPP Ports Option
K85 ½" NPT cable entry Option

FP06P S1 04 32 NU V 58 A M 135 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on page 14.
The solenoid must be used in conjunction with a correctly matched, Intrinsically Safe (IS) solenoid driver.
The valve installer is responsible for a correct and safe IS system.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
17
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
FP10P Selection Chart

FP10P
Dimensional Drawing
SCHEMATIC 3/2 NU
68 86.5
34 50
NU Normally
TYPE ‘M’
OVERRIDE
Universal offered
OPTION 1 as standard.
2
3

SCHEMATIC 2/2 NC
Valve suitable for
M20 x 1.05P Universal operation
CABLE ENTRY
2/2 & 3/2.
Normally Open and
191

1
2
166.5

EXTERNAL Normally Closed.


EARTH STUD
3 Plug port 3 for 2/2
135.6

Normally Closed
1 SCHEMATIC 2/2 NO function. (Plugs
2 available as a line
MOUNTING POSITIONS
61.5

2 x M6 x 9.5 DP item).
47.8
46.5

3
Plug port 1 for 2/2
35.9
20.8

17.8

1 Normally Open
2 function. (Plugs
= =

44.45 q
3 available as a line
Body Ported Shown item).

FP10P Selection Chart - Ordering Example


FP10P Model Code
S1 10 bar maximum valve pressure
S2 16 bar maximum valve pressure (For AC Coils = 6.5 Watts) Operator
S3 35 bar maximum valve pressure - ¼" only standard temperature (Typically 0.4 CV)
04 ¼" NPT body ported
06 3⁄8" NPT port blocks Connections
08 ½" NPT port blocks
32 3-way, 2-position
Valve Configuration
NU Normally Universal
S Nitrile (-20ºC to +130ºC) For maximum operating temperatures
V Viton (Standard) (-20ºC to +180ºC) see 'T' Rating Limitations for Ex emb
AG Silicone (-60ºC to +180ºC) O-ring Material
AL Fluorosilicone (-60ºC to +180ºC) & Ex d on pages 12 & 13.
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
Solenoid *
77 (Ex d) Page 13 - Table 2 **
74(Ex emb) 77(Ex d)
A ATEX/IECEx Dual Certified/Labelled  
G GOST x  Solenoid Approval
I INMETRO x 
N NEPSI* x 
U CSA (US) ATEX Dual Certified/Labelled x 
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid Voltage
option tables. 77 (Ex d) Page 13 - Table 2
M Electrical to switch or temporary manual override
ML Electrical and manual required to latch or temporary
manual override (3.0 Watts Ex d Only) Options
MLT Electrical and manual required to latch - tamperproof
LE Latched Energised (NO/NC Only) (6.5 Watts Ex d Only)
XX Power (W) 74 (Ex emb) - 3.6 & 4.4 & 6.8 Watts Page 12 - Table 1
Power
77 (Ex d) - 3.5 & 5.7 Watts Page 13 -Table 2
K6 BSPP Ports Option
K85 ½" NPT conduit entry Option

FP10P S2 08 32 NU V 77 A 24D ML 35 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
18 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
FP12P Selection Chart

FP12P
Dimensional Drawing
SCHEMATIC 3/2 NU
68 86.5

34 50

TYPE ‘M’ NU Normally


OVERRIDE
OPTION Universal offered
1
2 as standard.
3

SCHEMATIC 2/2 NC
M20 x 1.5P
CONDUIT ENTRY Valve suitable for
universal operation
EXTERNAL
2/2 & 3/2.
225.5

EARTH STUD
1 Normally Open and
200.8

2
MOUNTING POSITIONS
Normally Closed.
170

2 x M6 x 10 DP
3
Plug port 3 for 2/2
1 Normally Closed
SCHEMATIC 2/2 NO function. (Plugs

96
2
available as a line

67
61

3
item).
43.8
26.5

19.5
Plug port 1 for 2/2
1 Normally Open
27.8 8.5
2 function. (Plugs
44.45 q 3 available as a line
102.8
item).

FP12P Selection Chart - Ordering Example


FP12P Model Code
S1 10 bar maximum valve pressure - standard Operator
08 ½" NPT port blocks Connections
32 3-way, 2-position
Valve Configuration
NU Normally Universal
S Nitrile (-20ºC to +130ºC)
For maximum operating temperatures
V Viton (standard) (-20ºC to +180ºC) O-ring Material
see 'T' Rating Limitations for Ex d
AG Silicone (-60ºC to +180ºC)
on page 13.
AL Fluorosilicone (-60ºC to +180ºC)
XX Refer to Solenoid options tables. 77 (Ex d) Page 13 - Table 2 Solenoid *
77(Ex d)
A ATEX/IECEx Dual Certified/Labelled 
G GOST  Solenoid Approval
I INMETRO 
N NEPSI* 
U CSA (US) ATEX Dual Certified/Labelled 
XXX Voltage, refer
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables

M Electrical to switch or temporary manual override


ML Electrical and manual required to latch or temporary
manual override (3.0 Watts Ex d Only) Options
MLT Electrical and manual required to latch - tamperproof

120 12 Watts - auto reset


65 6.5 Watts - manual reset only (ML) Power

K6 BSPP ports Option


K85 ½" NPT conduit entry Option

FP12P S1 08 32 NU V 77 A 24D ML 65 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on page 13.
* For China (NEPSI), please note that the solenoid operator is Type 87.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
19
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
SJ06 Selection Chart

SJ06
Dimensional Drawing
68 86.5
SCHEMATIC 3/2 NC
34 50

TYPE ‘M’ T
OVERRIDE
OPTION

3
2

M20 x 1.5P 1
CABLE ENTRY EXTERNAL
EARTH STUD
19
221.3

MOUNTING POSITIONS
2 x Ø5.5 THRO' HOLES
196.6

SCHEMATIC 3/2 NO
165.8

=
28
=

T
VIEW OF DETAIL 'A'
1/8" NPT 31.4
PILOT VENT
DETAIL A
59.5

1 2 3
3
2
15
38.1 31.4
48 1
93.5

SJ06 Selection Chart - Ordering Example


SJ06 ¼" NPT
ASJ06 ¼" NPT Low Temperature Model Code

E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
32 3-way, 2-position
NC Normally closed Valve Configuration
NO Normally open
00 Spring return end cap 03 Spring cap with mechanical latch
02 Spring cap with E1 Internal Pilot Secondary Actuator
microswitch plunger
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13- Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **

74(Ex emb) 77(Ex d) 78(Ex ia)


A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables 78 (Ex ia) Page 14 - Table 3
XX Power (W) 74 (Ex emb) -1.8 & 3.6 Watts Page 12- Table 1
77 (Ex d) - 1.5 & 3.0 Watts Page 13- Table 2 Power
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP Ports Option
K85 ½" NPT conduit entry Option

SJ06 E1 32 NC 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
20 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
S06,S09 & S12 Selection Chart

S06, S09 & S12


Dimensional Drawing
SCHEMATIC 3/2 NC

68 86.5

50
T
34

TYPE ‘M’
OVERRIDE
OPTION

3
2

M20 x 1.5P EXTERNAL


CABLE ENTRY EARTH STUD
36.4
212.5

MOUNTING POSITIONS
3 x Ø5.2 THRO' HOLES SCHEMATIC 3/2 NO
187.9
157.1

=
38

T
=

VIEW OF DETAIL 'A'


1/8" NPT
PILOT VENT 20.7
50.8

52.2

DETAIL A 1 2 3
3
36.3 2
50.8 52.2
67.4
125.3 1

S06/S09/S12 Selection Chart - Ordering Example


S06 ¼" NPT
S09 3⁄8" NPT Model Code
S12 ½" NPT
E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
22 2 - way, 2 - position
52 5 - way, 2 - position Valve Configuration
32 3 - way, 2 - position
NC Normally Closed NO Normally Open Valve Configuration
XX 52 Valves Only
00 Spring return end cap 03 Spring cap with mechanical latch
02 Spring cap with E1 Internal Pilot Secondary Actuator
microswitch plunger
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **
74(Ex emb) 77(Ex d) 78(Ex ia)
A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables.
XX Power (W) 74 (Ex emb) - 1.8 & 3.6 Watts Page 12 - Table 1 Power
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP ports Option
K85 ½" NPT conduit entry Option

S06 E1 32 NC 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
21
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
SPR Selection Chart

SPR
Dimensional Drawing

86.5 180

50 155.4

124.6
SCHEMATIC 3/2 NU
TYPE ‘M’
OVERRIDE
OPTION

EXTERNAL
M20 x 1.5P
162.2

CABLE ENTRY EARTH STUD


MOUNTING POSITIONS
3
128.2

2 x M5 x 9 DP

VIEW OF DETAIL 'A' 2 3


2

84.7
77.7

1
61.2
1
44.7

37.7

= =
24
38.1 96.5
DETAIL A

SPR Selection Chart - Ordering Example


SPR 12 ½" NPT
SPR 19 ¾" NPT - (External Pilot Only)
SPR 25 1" NPT - (External Pilot Only)
ASPR 12 ½" NPT - Low Temperature Service Model Code
ASPR 19 ¾" NPT - Low Temperature Service (External Pilot Only)
ASPR 25 1" NPT - Low Temperature Service (External Pilot Only)
E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
32 3 - way, 2 - position Valve Configuration
52 5 - way, 2 - position
NU Normally Universal Valve Configuration
XX 52 Valves Only
00 Spring return end cap Secondary Actuator
EI Internal Pilot
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **
74(Ex emb) 77(Ex d) 78(Ex ia)
A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables.
XX Power (W) 74 (Ex emb) - 1.8 & 3.6 Watts Page 12 - Table 1
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2 Power
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP ports Option
K85 ½" NPT conduit entry Option

SPR E1 32 NU 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
22 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Accessory Information

Options
Product Options

The range of products displayed in this brochure, are designed to accommodate all the options shown below. If the style
or arrangement required for your application is not shown, please contact our office with full description and specification
details.

Type M - Electrical to Switch or Temporary Type MOR - Electrical to Switch or Temporary


Manual Override Manual Rotary Override

Manual Override Type M Manual Rotary Override Type MOR


The solenoid valve switches on and off with the electrical
The solenoid valve switches on and off with the electrical
supply. The manual override button can be pressed to
supply. The manual override rotary operator can be
operate the valve when the solenoid is in the electrically
turned to operate the valve when the solenoid is in the
de-energised position. The manual override is
electrically de-energised position. The manual override is
non-detented, i.e. does not latch in position. When the
detented, i.e. does latch in position.
button is released, the valve spring returns.

Type ML - Electrical and Manual Required to Switch


or Temporary Manual Override
Type MLT - As above - Tamperproof Type LE - Latched Energised

Manual Reset Type ML & MLT Latch Energised Type LE


For Types ML and MLT, apply the electrical signal and press
Designed specifically for Deluge systems. The solenoid
the reset button. With type ML, the valve moves to the
valve can be used in the electrically de-energised
energised position and will not de-energise until the
condition. When an electrical signal is applied to the valve,
electrical supply is removed. The manual reset button also
the valve shifts to the energised position and stays in this
acts as a manual override, when the valve is in the
position, even if the electrical signal is removed, and until
de-energised position and the electrical supply is off. The
the valve is manually moved back to the de-energised
manual reset is non-detented, spring return, i.e. does not
position by pressing the reset button. The valve can only
latch in position. With type MLT, the valve cannot be
be manually reset after the electrical signal is removed.
moved to the energised position by pressing the button if
The reset button is fitted at the base of the valve.
there is no electrical supply to the solenoid.

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
23
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Accessory Information

Options
Product Options for Type 58

The range of products displayed in this brochure, are designed to accommodate all the options shown below. If the style
or arrangement required for your application is not shown, please contact our office with full description and specification
details.

Type M / ML - Electrical to Switch or Temporary Auto Reset Electrical to Switch


Manual Reset (Slimline 58 - Series) (Slimline 58 - Series)

Manual Override Type M & Manual Reset Type ML

The solenoid valve switches on and off with the electrical supply. The manual override button can be pressed to operate the
valve when the solenoid is in the electrically de-energised position. The manual override is non-detented, i.e. does not latch
in position. When the button is released, the valve spring returns.

For Type ML, apply the electrical signal and press the reset button. The valve moves to the energised position and will not
de-energise until the electrical supply is removed. The manual reset button also acts as a manual override, when the valve is
in the de-energised position and the electrical supply is off. The manual reset is non-detented, spring return, i.e. does not latch
in position.

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
24 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Models FP06P, FP12P, SJ06, S06, S09, S12 & SPR

Solenoid Valves

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
25
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Installation Workover Control System (IWOCS)

HPU & Wellhead

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
26 www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
BFD15/2 December ‘12 responsibilities of the system designer and user. to the specifications and design etc., without prior notice.
© Bifold 2012
Installation Workover Control System (IWOCS)

HPU & Wellhead

Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
27
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012
Instrument, Process,
Directional Control Valves,
and Pumps

Pneumatic and
Instrumentation Valves
Hydraulic Valves
Subsea Valves
Hydraulic Pumps,
Intensifiers and Valves

Quality Assurance
All Bifold products are manufactured to a most stringent
Accuracy of Information QA programme. Every care is taken at all stages of
We take care to ensure that product information in this manufacture to ensure that every product will give When selecting a product, the applicable operating
catalogue is reasonably accurate and up-to-date. However, optimum performance and reliability. We are third system design must be considered to ensure safe use.
our products are continually developed and updated so to party certified to BS EN ISO 9001:2008. Functional test The products function, material compatibility, adequate
ensure accurate and up-to-date information please refer to certificate, letter of conformity and copies of original mill ratings, correct installation, operation, and maintenance
the product catalogue issue list on our web site or contact certificates, providing total traceability are available on are the responsibilities of the system designer and user.
a member of our sales team. request to BS EN 10204 3.1 where available. We reserve
the right to make changes to the specifications and
design etc., without prior notice.

UK Office USA Office Singapore Office


Bifold Fluidpower Ltd Marshalsea Hydraulics Limited Bifold Fluidpower Ltd Bifold Fluidpower Ltd
Bifold, Bifold Fluidpower, Bifold Subsea Greenside Way, Marshalsea House,Venture Way 11490 Westheimer, Toa Payoh Industrial Park,
and Marshalsea Hydraulics Ltd Middleton, Manchester, Priorswood Industrial Estate Suite 850, Lorong 8 #07-1475,
are all members of the Bifold Group.
M24 ISW. UK. Taunton, Somerset,TA2 8DE. UK. Houston,TX, 77077. Singapore, 3109075.
Registered No. 1787729 in England.
Registered Office: Greenside Way, Tel: +44 (0) 161 345 4777 Tel: +44 (0) 1823 331081 Tel: +1 (713) 783 4253 Tel: +65 6735 1323
Middleton, Manchester, M24 ISW. Fax: +44 (0) 161 345 4780 Fax: +44 (0) 1823 323382 Fax: +1 (713) 783 0067 Fax: +65 6735 1367
Email: marketing@bifold.co.uk Email: info@marshalsea.co.uk Email: marketing@bifold.co.uk Email: marketing@bifold.co.uk
Web: www.bifold.co.uk Web: www.bifold.co.uk Web: www.bifold.co.uk Web: www.bifold.co.uk

Innovative and Reliable


www.bifold.co.uk
Valve Solutions
BFD15/2 December ‘12 © Bifold 2012

You might also like