Professional Documents
Culture Documents
ch12 Footing Design
ch12 Footing Design
PD = 20 k/ft
PL = 15 k/ft select h = 20 in.
Pu = 48 k/ft d= 16.50 in.
t= 12 in. Mu = 48.6 ft-k
cover = 3 in. Rn = 198.3471 psi
fc' = 3000 psi r = 0.00345
gc = 145 pcf As,flexure = 0.682 in2/ft
gs = 100 pcf As,t&s = 0.432 in2/ft
fy = 60000 psi As,min = 0.660 in2
l= 1.00 As = 0.682 in2/ft
qa = 4.00 ksf
dgrade = 4.00 ft stheor T&S
trial h = 12.00 in. #3 1.93 in. 3.06
d= 8.50 in. #4 3.52 in. 5.56
qe = 3.55 ksf #5 5.45 in. 8.61
lmin = 9.86 ft #6 7.74 in. 12.22
l= 10 ft #7 10.55 in. 16.67
qu = 4.8 ksf #8 13.90 in. 21.94
Vu = 18.20 k/ft #9 17.59 in. 27.78
dshear = 18.46 in. Select a bar size and
hshear = 21.96 in. spacing from the table
above
trial h - hshear = -9.96 in.
Square Single Column Footing Design
PD = 200 k Two-way Shear
PL = 160 k Vu2 = 442.4 k
Pu = 496 k bo = 142 in.
a= 16 in. as = 40.00
b= 16 in. bc = 1
cover = 3 in. d2,shear = 18.96 in.
fc' = 3000 psi d2,shear = 12.6405 in.
gc = 145 pcf d2,shear = 10.12 in.
gs = 100 pcf d2 = 18.96 in.
fy = 60000 psi h2 = 23.46 in.
l= 1.00 trial h - h2,shear = 0.54
qa = 5.00 ksf
dgrade = 5.00 ft One-way Shear
trial h = 24.00 in. Vu1 = 121.70 in2
d= 19.50 in. d1,shear = 13.72 in.
qe = 4.40 ksf h1,shear = 18.22 in.
lmin = 9.05 ksf trial h - h1,shear = 5.78 in.
l= 9 ft
qu = 6.12 ksf
select h = 24 in.
d= 19.50 in.