MICROCODE VERSION 21-14-25-00/00


RELEASED 07/19/06
Newly supported features and functions for Version 21-14-25-00/00

1. Mainframe and Open System


NONE

2. Mainframe System
NONE

3. Open System

3-1 Information Enhancement for Mode Select Parameter Page


Description When different hosts changed the same LDEV parameter page using the Mode Select command,
the processing could not succeed and the server down occurred. In order to identify if there is a
micro-program bug or not in this case, an information enhancement log about the parameter page
is output.

When the Mode Select command ends normally, the below information enhancement SSB are
output once per 10 minutes for each MP for the pages that support the command.
If system option mode 339 is set to ON, the following SSB are not output.

Page01H : SSB=0xd4f3
Page02H : SSB=0xd4f4
Page03H : SSB=0xd4f5
Page04H : SSB=0xd4f6
Page08H : SSB=0xd4f7
Page0AH : SSB=0xd4f8
Page18H : SSB=0xd4f9
Page19H : SSB=0xd4fa
Page20H : SSB=0xd4fb

Changed Part DKCMAIN


Note None

HDS Confidential 1of 2


The change of contents for Version 21-14-25-00/00

(1) PGR Command Preempt & Abort TOV


Item Description
Contents In the alternate path configuration, when the host accessed the subsystem via multiple paths
simultaneously, the subsystem did not respond.
Conditions The problem may occur with all conditions met.
1. Persistent Reserve environment (AIX/MSCS/Tru64/ (SUN with HA software))
2. During I/O operations
Category OPEN
Changed DKCMAIN

(2) Improvement of HDD Command Response


Item Description
Contents HDD command response delay may occur in the rare case after idling. The HDD micro-program
modified to improve the HDD command response.
Category HDD
Changed DKU Micro-program

(3) Memory reservation error when using Storage Navigator


Item Description
Contents When using Spreadsheet or Export tool on the Storage Navigator, the "Please call the Support
Center" message displayed.
Hi-Command operations not performed.
Conditions With either condition met, the SVP memory may run out.
1. Without rebooting the SVP, switch View to Modify using the Storage Navigator for 40,000
times or more.
2. The SVP has not been rebooted for four months or longer while Hi-Command is connected.
Category RMI
Changed SVP