You are on page 1of 52

 

 
 

 
 
 

B73
37T
7Th
heo
ory
ry
 

Bo
oein
ng 737N
7 7NG
S stem
Sys ms
s
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INTENTIONALLY LEFT BLANK 
   


 
Foreword: 

 
This booklet describes systems published in our Facebook pages: 
 
About 
This FB page is to interact throughout the B737 community and has NO direct link to any user 
company.  
THE CONTENT SHALL NOT BE USED FOR ACTUAL OPERATION OF THE AIRCRAFT. 
The administrator has NO RESPONSIBILITY to the content written on these pages. 
 
Description 
Creator:  Ferdi Colijn 
Administrators:  Ferdi Colijn (B737NG Type Rated) 
  Maarten van Klaveren (B737‐900ER First Officer) 
  Bert de Jong (Flight Engineer) 
 
 
 
B737Theory 
March 24 
 
The goal of this FB page is to expand B737 theoretical knowledge among users and we try to achieve 
that by expanding the amount of visitors aiming for interaction. 
 
There rest no copyright on our stories but we rather see you recommending us on your private FB 
pages iso sharing the posts. 
 
Also feel free to "donate" your experiences and stories on B737Theory and drop us a line by sending 
a message. We will evaluate and post them in time. Be aware that it must not be a copy from any 
manual or else we interfere with a copyright that is also the reason why we do not publish 
schematics on the page. 
 
Thank you 
 
   


 
 
Contents: 
 
Foreword: ................................................................................................................................................ 2 
APU .......................................................................................................................................................... 6 
Auto Slat System...................................................................................................................................... 7 
Engine Electronic Control (EEC) ............................................................................................................... 8 
When things go wrong and beyond basic systems knowledge ............................................................... 9 
Engine fire detection ............................................................................................................................. 11 
Feel Differential ..................................................................................................................................... 12 
Fuel Scavenge Jet Pump ........................................................................................................................ 13 
Fuel valves ............................................................................................................................................. 14 
AC Generator ......................................................................................................................................... 15 
Isolation valve ........................................................................................................................................ 17 
Manual gear extension. ......................................................................................................................... 18 
Mechanical pressure relief valves. ........................................................................................................ 19 
Nitrogen Generating System ................................................................................................................. 20 
Outflow valve. ....................................................................................................................................... 21 
Flight Control “Breakaway” Devices ...................................................................................................... 22 
Pack & pack control ............................................................................................................................... 23 
Recirculation fans .................................................................................................................................. 24 
Hydraulic Reservoirs .............................................................................................................................. 25 
The APU Starter/Generator. .................................................................................................................. 26 
Landing Gear Transfer Valve ................................................................................................................. 27 
PTU ........................................................................................................................................................ 28 
Wing Thermal Anti Ice (WTAI) ............................................................................................................... 29 
B737 Yaw damping ................................................................................................................................ 30 
Zone temperature control ..................................................................................................................... 31 
Lavatory “fire protection”. .................................................................................................................... 32 
Center tank boost pumps ...................................................................................................................... 33 
Antiskid .................................................................................................................................................. 34 
Leading Edge Flaps ................................................................................................................................ 35 
Thrust Reverser ..................................................................................................................................... 37 
Tail Skid .................................................................................................................................................. 39 
Vortex generators.................................................................................................................................. 40 
Window heating .................................................................................................................................... 41 
Wing& Body Overheat ........................................................................................................................... 42 
Horizontal Stabilizer Trim. ..................................................................................................................... 43 


 
Display Electronic Units. ........................................................................................................................ 44 
Proximity Switch Electronic Unit ........................................................................................................... 45 
Nose wheel steering lockout ................................................................................................................. 46 
Weather radar ....................................................................................................................................... 47 
Dissolved air .......................................................................................................................................... 49 
Frangible fittings .................................................................................................................................... 50 
Rudder(vertical stabilizer) load reduction ............................................................................................. 51 
 
   


 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INTENTIONALLY LEFT BLANK 
   


 
APU 

The  APU  is  a  constant  speed  (±  49.000  RPM)  gas  turbine  engine  that  can  supply  AC  power  and 
pressurized air.  The starter/generator is powered from either directly the main battery (28VDC) or 
transfer bus 1 (115VAC) where either source is converted into 270VDC for starter operation. At 95% 
starter operation reverses to a 90 KVA generator, indicated by the blue APU OFF BUS light. (90 KVA 
until  32.000  ft.  and  66  KVA  until  41.000  ft.)  Starter  sequence  is  automatically  determined  by  the 
Electronic Control Unit (ECU) that needs the battery switch to be in the ON position to energize. 
 
The APU can be used for air and AC power until 10.000 ft., just air to 17.000 ft. and just AC power 
until 41.000 ft. That is also the maximum starting altitude although recommended at 25.000 ft. Air 
takes  the  biggest  performance  from  the  APU  as  it  takes  air  from  the  load  compressor  which  is 
mounted on a common shaft with the combustion compressor. The more air taken in, the lower the 
performance  of  the  APU.  That  is  why  there  is  a  restriction  in  altitude  use,  especially  with  air  and 
when the demand is large (high EGT), air use is squeezed by IGV’s toward the load compressor. When 
on suction feed the APU draws fuel from tank #1 and when operating for an extended time select a 
fuel pump to pressure feed which extends the lifetime of the APU. 
 
The ECU protects the APU and shuts down with a low oil pressure, overspeed or when a FAULT light 
illuminates.  The  latter  represents  more  than  just  the  foregoing,  including  ECU  failure,  loss  of  DC 
power, APU fire, overtemp (during start), high oil temp and many more. The start limit is 2 minutes 
and a FAULT light illuminates when the start is aborted through a protection or when the generator 
malfunctions.  A  blue  MAINT  light  illuminates  when  oil  quantity  is  low  or  a  generator  malfunction 
occurred, the APU is still allowed to operate. 
 
APU  compartment  and  oil  cooling  is  accomplished  by  exhaust  air  used  as  an  educator  to  draw 
outside air into the compartment from an inlet just above the exhaust. 
When  the  APU  is  stopped  by  placing  the  switch  to  OFF,  the  ECU  determines  a  cooling  cycle  of  1 
minute before the APU actually stops. The cooling cycle closes the APU BAV and trips the generator 
OFF line. By doing so it reliefs the APU from load and decreases the EGT preventing so called cooking 
of the nozzles. (residual fuel forms carbon on the hot nozzles which can affect the flame pattern) 
Delay switching the Battery to OFF to 2 minutes after selecting the APU to OFF, this allows the inlet 
door  to  close.  The  door  closes  when  the  APU  decelerates  to  ±  30%  to  prevent  the  inlet  duct  to 
collapse. The 1 minute is by‐passed when the APU shuts down through a malfunction, the Fire Switch 
is activated or when the Battery Switch is selected to OFF. 
 

   


 
Auto Slat System 

The  Auto  Slat  system  operates  the  LE  slats  automatically  in  flight  when  you’re  approaching  a  stall 
under certain conditions just before the stick shaker becomes active.  
 
These conditions are when the flaps are at position 1 – 5 and hydraulic pressure is available through: 
• Hydraulic system B 
• PTU (extend & retract) 
• Standby hydraulic system (extend only) 
 
*  With Alternate Flap use, the Auto Slat function is not available. 
*  With a short field performance configuration the Auto Slat operates with flap selections 1 – 25. 
 
At  the  flap  position  1  –  5  the  LE  slats  are  in  the  intermediate  (extend)  position  and  the  LE  flaps  at 
their  only  extended  position  .  .  .  FULL.  When  the  aircraft  approaches  the  stall  angle/speed  region 
determined by the Stall Management and Yaw Damper (SMYD) computer, the Flaps/Slats Electronic 
Unit (FSEU) command the LE slats to the FULL extend position to prevent entering a stall condition. 
Another  action  by  the  FSEU  is  to  delay  the  “transit  lights”  to  operate  for  12  seconds  thereby 
preventing the LE devices transit lights to illuminate. 
When thrust is increased/stick force relaxed and the aircraft flies out of this condition (higher speed, 
lower AOA) the Auto Slat system drives the LE slats back to the intermediate extend position. Also 
here the transit lights will not illuminate. 
 
When  the  Auto  Slat  systems  fails  to  operate  or  is  not  available  by  any  cause,  the  AUTOSLAT  FAIL 
indication  illuminates  on  the  flight  control  panel.  When  1  SMYD  computer  fails  the  other  will 
automatically  take  over  and  would  go  unnoticed  unless  you  press  RECAL  during  an  Auto  Slat 
condition. 
   


 
Engine Electronic Control (EEC) 

The EEC is mounted on the right top side of the fan duct and exists of two computers (channel 1 & 2), 
where one is active and the other standby although they’re both operating and cross linked during 
normal  operation.  The  EEC  receives  numerous  environmental  and  engine  input  signals  to  calculate 
fuel  and  control  outputs  to  operate  the  engine  and  identifies  the  engines  thrust  rating  by  a  pre‐
selected identification plug. Doing so it heats up and needs to be cooled which is achieved by tapping 
off, and directing fan air to the EEC. 
 
Normal power source of the EEC is an alternator mounted on front of the engine gearbox but is only 
valid when the gearbox (N2) reaches 15%. Before 15% N2, the EEC is powered by Transfer Bus 1 or 2 
(Eng. 1 or 2) if available, and becomes energized when the Start Switch is placed to GRD or CONT or, 
when  the  Start  Lever  is  moved  to  IDLE.  A  de‐energized  EEC  is  indicated  by  blank  engine  indication 
boxes on the upper and lower DU’s even when the EEC button illuminates a white ON, just indicating 
that the EEC is selected to the normal mode. In this case the only indication visible directly from the 
sensors  are  N1,  N2,  Oil  quantity  and  the  vibration  indicator,  all  others  are  blank.  So  .  .  .  during  a 
battery  start  (emergency  power),  indications  of  EGT,  fuel  flow,  oil  pressure  and  oil  temperature 
remain blank until the alternator reaches 15%.  
 
On the aft overhead engine panel there are the two guarded EEC control buttons to select the EEC to 
the  NORMAL  mode  of  operation  (white  ON  light),  or  the  manual  HARD  ALTERNATE  mode  of 
operation (amber ALT light). An undispatchable failing EEC is indicated also on the engine panel by a 
ENG  CONTROL  light  and  will  only  illuminate  when  on  the  ground  and  the  engine  N2    >50%.  
A little teaser . . . . the last indication on the engine panel are two REVERSER lights . . . when and how 
long do they illuminate amber during normal operation? 
   


 
When things go wrong and beyond basic systems 
knowledge 

The next post is an actual situation that happened, losing a Transfer Bus in flight. I’ve tried to simplify 
the  explanation  but  in  fact  it’s  just  an  indicator  of  what  CAN  happen.  At  this  point  Non  Normal 
Procedures, CRM and common sense is needed to fly out of these situations. 
 
It  started  with  a  MASTER  CAUTION  and  a  right  SOURCE  OFF,  indicating  that  XFR  bus  2  was  not 
powered  by  its  “last  selected  source”  but  by  Transfer  Bus  1.  QRH  tells  us  to  select  the  GEN  switch 
(affected side) ON what this time caused a TRANSFER BUS 2 OFF to illuminate with additional related 
indications.  (DEU  2  and  others,  (check  the  power  source  booklet  to  find  out)  Next  the  APU  was 
started and when attempted to connect the generator, a BATTERY DISCHARGE illuminated indicating 
an  excessive  discharge  of  a  battery,  with  multiple  additional  indications.  The  crew  decided  to  stop 
further procedures and investigation and used the system “as is”. To give you an idea, the Indications 
involved: battery discharge, master caution, right hand source off, right hand transfer bus off, Mach 
trim fail, auto slat fail, fuel pump 2 fwd., fuel pump 1 aft, electrical hydraulic pump #2, probe heat B, 
engine EEC alternate, zone temperature. 
 
After this ordeal the crew managed to land safely with this reduced electrical power condition and 
multiple caution indications. 
 
 
What  actually  has  happened  was  that  the  Generator  Control  Unit  (GCU)  2  had  received  an  erratic 
signal through the Line Current Transformer (LCT) that IDG2 was connected to the transfer bus. This 
signal  is  then  transferred  to  the  Bus  Power  Control  Unit  (BPCU)  who  arranges  switching  in  the 
electrical AC system to provide in the two major rules: 
• No paralleling of AC sources 
• An AC source connecting to a Transfer Bus disconnects the previous source (look at the first 
rule) 
 
This erroneous signal locked out the possibility to connect the APU or other AC sources like Transfer 
Bus 1 to Transfer Bus 2. However, as IDG 2 in fact was not connected, transfer bus 2 lost power. The 
erroneous  indication  must  have  originated  at  the  GCB  2  (unit  connecting  IDG  2  to  bus  2)  itself, 
indicating the switch had closed although it had not moved.  
 
   


 
The BATTERY DISCHARGE is probably caused by the a (excessive) main battery discharge by powering 
the Battery Bus as also the DC 2 system (TR 2 & TR 3) were not powered anymore and illuminates 
when a battery output conditions exists of: 
• Current draw is more than 5 amps for 95 seconds 
• Current draw is more than 15 amps for 25 seconds 
• Current draw is more than 100 amps for 1.2 seconds. 
Mind you, normally when Transfer Bus 2 is de‐energized the Transfer 3 Relay would switch TR 3 to 
Transfer Bus 1 which obviously didn’t happen. 
 
 
 

10 
 
Engine fire detection 

The engine fire detection system consist of a fire, and an overheat detection inside the nacelle which 
are only active when the engine is operating. Temperatures are guarded by 2 (A & B) detector loops 
which operate by expanding gas pressure inside the loop elements thereby activating an OVERHEAT, 
a FIRE or a FAULT (leaking loop tube) contact. The engine areas covered by the loops are inside the 
nacelles around the fan, and the “core” hot section so . . . a torch (see image) would go undetected 
as it occurs inside the engine. 
 
• OVERHEAT detection is indicated by an OVHT/DET, 2 MASTER CAUTION and respective ENG 
OVERHEAT indication. (± 170°C around the fan section and 340°C around the hot section) 
• FIRE detection would be indicated by 2 MASTER FIRE WARNING, the respective FIRE SWITCH, 
an OVHT/DET, 2 MASTER CAUTION and an audio FIRE BELL warning. (± 300°C around the fan 
and 450°C around the hot section) 
 
When either of the foregoing occurs the fire switch unlocks to allow it to be pulled up. 
 
A fire or overheat is detected when both loops exceed the mentioned limits and when one loop fails, 
it’ll  go  unnoticed  and  the  detection  system  automatically  switches  to  a  single  loop  operation.  One 
failing loop will only illuminate a FAULT during a test (also not on RECALL) and when both loops fail, 
the FAULT light illuminates but NOT the MASTER CAUTION. 
 
The detection tests on preflight are: 
• The OVHT/FIRE test which checks the operation of the engine & APU fire detection control 
module located in the E&E bay and not to forget the indications on the flight deck. 
• A  FAULT/INOP  test  checks  the  FAULT  detection  circuits  (loops  and  elements)  and  the  flight 
deck indications by simulating a dual loop failure. 
 
Note that the APU fire detection also operates during the FIRE test and is visible/audible in the right 
main wheel well on the APU Ground Control Panel during pre‐flight. 
   

11 
 
Feel Differential 

The FEEL DIFF PRESS indication on the flight control panel can illuminate in the following cases.  
 
(The  feel  system  simulates  “actual  feel  forces”  at  the  control  column  from  the  hydraulically 
supported elevator panels) 
 
1.  The  first  one  is  related  to  a  differential  of  A  &  B  hydraulic  pressure  to  the  elevator  feel  system. 
When  either  hydraulic  system  pressure  drops  >  25%  related  to  the  higher  pressure,  the  FEEL  DIFF 
PRESS  light  illuminates  on  the  flight  control  panel  with  a  30  second  delay.  The  30  second  delay 
prevents the light from “flickering” when pressure drops in either system by a high demand such as 
gear selection. 
 
2. The second is related to the dynamic air pressure supply to the Elevator Feel Computer. It receives 
dynamic pressure from the two pitot tubes mounted on either side of the vertical stabilizer. When 
the  computer  receives  an  erratic  signal  it’d  be  the  same  as  the  pressure  drop  and  the  light 
illuminates. (failed probe heater and icing conditions) 
 
3.  The  third  is  related  to  the  Stall  Management  and  Yaw  Damper  (SMYD),  and  a  so  called  Elevator 
Feel  Shift  module  (EFS),  which  creates  a  ±4  times  higher  forward  control  column  force  when 
approaching the stall region. This force uses a reduced system A pressure and when this reducer fails, 
opening prematurely providing a higher than normal A system pressure to the feel actuator, the FEEL 
DIFF PRESS also illuminates after 30 seconds. 
 
Note  on  the  last  system,  it’s  inhibited  <100  ft.  RA  and  AP  selected,  and  when  the  EFS  is  not 
operational. 
   

12 
 
Fuel Scavenge Jet Pump 

De fuel scavenge jet pump scavenges residual trapped fuel from the center tank to tank #1. 
 
Even at 0 Kgs indication there is still some residual fuel in the center tank. This fuel is trapped and 
cannot  be  sucked  up  by  the  scavenge  line  of  the  center  tank  boost  pumps  because  of  its  elevated 
position. To be able to use this last bit of fuel, a center tank scavenge system is provided. To activate 
the  system,  next  conditions  need  to  be  met;  the  LEFT  FWD  pump  operating  and  tank  #1  quantity 
lower than half full. (< 1990 Kgs) When the float type shutoff valve opens, it allows LEFT FWD fuel 
pump  flow  to  create  a  negative  pressure  in  the  (non‐rotating  parts)  eductor  type  scavenge  pump 
which in turn draws fuel from the center tank relieving it in tank #1. Of course this will create over 
time (the pump capacity is 100–200 Kgs/hr. (AMM)) a relatively small imbalance between the main 
tanks. The book says that the system continues to run for the remainder of the flight (can’t be shut 
off) but when you’ll remove the controlled condition (LEFT FWD fuel pump) also the jet pump stops 
operating. When the center tank is depleted, the scavenge pump draws air from the center tank to 
tank #1 which obviously does no harm to engine #1 operation. 
 
Note: the “dissolved air” story of fuel. When on suction feed with a high fuel temperature and a rapid 
decreasing pressure over the fuel, air bubbles (aeration) appear in the fuel possibly causing engines 
to run erratic or even flame out when sucked up though the bypass valve. 
 
Note:  when  both  center  tank  fuel  pumps  are  inoperative,  fuel  will  be  trapped  in  the  center  tank. 
There is no bypass valve provision for suction feed, also the left main tank quantity has to be below 
half full to even start the scavenge jet pump. Even so, the scavenge rate is insufficient to be used for 
emptying the center tank. Under these conditions you’ll use main tank fuel before the center tank is 
at  required  safe  levels  and  a  possible  overstress  of  the  wing  roots  arises. 
(>453, the main tanks have to be full and >726, CONFIG) 
   

13 
 
Fuel valves 

Let’s look at the most important valves in the fuel system, the Spar Fuel Valve and the Engine Fuel 
Valve a bit further than needed but still at an acceptable level. It will clarify what actually happens 
specifically with the Engine Valve. By all means just remember the easy way as the FCOM explains. 
 
The #1 most important fuel valve is the Spar Fuel Valve. This 28 VDC valve is mounted in the front 
wall  “spar”  of  the  main  fuel  tank  supplying  fuel  to  the  fuel  feed  line  of  the  engine.  The  DC  power 
comes from the Hot Battery Bus and the valve even has an own recharging Battery Power Pack to be 
able  to  positively  close  the  valve  in  case  of  an  emergency  such  as  a  separated  engine.  The  valve 
opens when the Start Lever is placed in the IDLE position and closes by CUTOFF of that Start Lever, or 
by pulling its Fire Switch. When the valve is closed it shows a dim blue light even with the Start Lever 
in CUTOFF as I always explain that any blue light is a “not standard flight condition light”, knowing 
that the book says it’s a status light. 
 
The Engine Fuel Valve is actually the High Pressure Shut Off Valve (HPSOV) and is integral with the 
Hydro  Mechanical  Unit  (HMU)  on  the  accessory  gearbox.  The  valve  opens  and  closes  by  the  same 
controls as the Spar Fuel  Valve but its actual opening is a bit  more complicated. It relies  on the so 
called Fuel Metering Valve (FMV) which is under control of the EEC. So . . when conditions meet the 
requirements  to  open  the  HPSOV,  the  EEC  signals  the  FMV  to  open  up  the  HPSOV  by  servo  fuel 
pressure.  
 
On  the  other  hand  the  closing  of  the  HPSOV  is  achieved  by  the  Start  Lever  or  Fire  Switch,  the  EEC 
energizes  the  CLOSED  SOLONOID  of  the  HPSOV  which  uses  28VDC  from  the  Battery  Bus.  During 
engine start this FMV is controlled by the EEC and when conditions dictate the HPSOV (Engine Fuel 
Valve)  to  close,  the  EEC  commands  the  FMV  and  thereby  the  HPSOV  to  close  in  the  following 
conditions: 
• A Hot Start occurs (>725°C) on the ground (exceedance  protection) 
• If the engine decays after idle speed during start below 50% N2 speed and EGT exceeds the 
start limit 
• The EEC senses a “wet start” meaning no EGT rise within 15 seconds after the Start Lever is 
at Idle (YOU are the start limit for the EGT rise which is 10 seconds!!!) 
 
All of these conditions will be indicated by a bright ENG VALVE CLOSED light. 
 
Note that with an updated EEC software (7.B.Q and later) the EEC also provides a protection when 
approaching a Hot Start meaning a rapid increase in EGT. 
The 115/200 VAC, 400 Hz, 90 KVA Integrated Drive Generator. 
   

14 
 
AC Generator 

I  recently  received  a  request  from  one  of  our  followers  to  explain  the  operation  of  a  brushless 
generator. I’ve send the explanation and thought on sharing this generic AC power generation info of 
an  aircraft  AC  brushless  generator.  I’ve  used  the  AC  generator  I’m  familiar  with  and  adjusted  the 
image toward that generic explanation and added the 737 protection circuits in the GCU. 
 
The AC Generator is an assembly of three generators: 
• Permanent Magnet Generator (PMG) 
• Exciter Generator 
• Main Generator 
 
The most important Rotor components of the AC Generator are: 
• Permanent Magnet Generator rotor 
• Exciter Generator Rotor; which includes also the Rotating Rectifiers (3) and resistors (3) 
• Main Generator Rotor 
 
The most important Stator components of the AC Generator are: 
• PMG Stationary Armature; output: 39 VAC, 1 ø, 600 Hz 
• Exciter Generator Stationary Field; input: 28 VDC pulsating, 1,200 Hz 
• Main Generator Stationary Field; output: 115/200 VAC, 3 ø, 400 Hz 
 
Once the engine gearbox (N2) on which the generator has been installed has come on speed, voltage 
is excited in the PMG. This will be a 39 VAC, 600 Hz, 1 ø, at 100% revolutions of the IDG (± 12,000 
RPM  of  the  generator).  This  voltage  is  fed  to  the  voltage  regulator  in  the  Generator  Control  Unit 
(GCU)  through a DC Power Supply where it is converted into a pulsating direct voltage of 28 VDC, 
1.200 Hz. 
 
The output of the voltage regulator is linked through the closed Generator Control Relay (GCR) to the 
Stator of the Exciter Generator which excites a 3 ø AC voltage in the Rotor. This AC voltage is than 
rectified by three rotating rectifiers and subsequently supplied to the Rotor of the Main Generator. 
 
The last step is that the Main Generator rotor field excites the required 115/200 VAC, 400 Hz, in the 
Main Generator Stator. The 115 VAC is the voltage taken from one phase and ground and the 200 
VAC is the voltage between two phases (115 x √3) which explains the ra ng of what the generator 
can generate (115/200 VAC).  
 
The  above  shows  that  there  is  no  need  an  external  voltage  source  to  ensure  the  generator  is  in 
operation, that’s why the system is also referred to as being "Self‐supported". 
 
OK  the  easy  way  is  that  the  Permanent  Magnet  Generator  (PMG)  rotates  by  the  IDG  on  the  same 
shaft  as  the  exciter‐,  and  Main  rotors.  The  generated  (39  VAC)  is  rectified  to  a  pulsating  DC  in  the 
control unit and send to the exciter stator. This DC power creates an alternate current in the exciter 
rotor and is rectified by the rotating rectifiers where after it finally creates an alternate current in the 
three main generator stator. This is the 115 VAC/400 Hz output of the generator and is monitored by 
the current transformers that relaxes or intensifies the DC power toward the exciter generator to the 
requested load of the electrical system. 
 

15 
 
The in the image shown protections in the CDU will de‐energize the GCR thereby de‐energizing the 
exciter  field,  which  de‐energizes  the  generator.  This  de‐energizing  GCR  also  occurs  when  the 
generator switch is selected OFF. 
 

16 
 
Isolation valve 

 
The isolation valve separates the left, from the right side of the bleed manifold. It is powered from 
AC Transfer Bus 1 but also can be manually opened/closed by a control lever, accessible in the left air 
condition bay. Because it’s AC power* it will fail in the selected position when power is removed. 
When the Isolation switch is in the AUTO position the valve opening relies on the so‐called “corner 
switch” positions. They are the Pack and Bleed switches, when all these switches are NOT in the OFF 
position the isolation valve is closed. On the other hand if any corner switch is selected to OFF the 
Isolation valve opens in the AUTO selection. 
When a Pack switch is OFF, the Isolation valve opens to create equal performance of the engines. 
When a Bleed is selected OFF the Isolation valve opens to allow air from either side of the manifold 
to be used for the off side WTAI. 
Note the isolation valve logic is related to switch position so a tripped pack or bleed will not open the 
Isolation Valve when in AUTO. After flight the Isolation valve should be selected OPEN just in case 
you need to battery start engines when there is no APU or external electrical power available. The 
ground air connection is located on the right side of the manifold close to engine #2. When N2 >20% 
there is no personnel allowed in the vicinity of the turning engine so we have to start engine #1 first. 
When this would be a battery start you’ll need the isolation valve to be open, so when you removed 
AC power with the isolation valve switch OPEN, the valve is still in the open position. 
 
* A general rule for electrical power is; “AC lies, DC dies”.  
This is a nice thing to know also for analog instruments, an AC powered instrument stays where it 
lost power and a DC powered instrument will drop off to zero. 
 
 

 
   

17 
 
Manual gear extension. 

Let’s have a look at this Non Normal procedure and its components. 
 
When the gear is UP and the LG lever in the OFF position, hydraulic system A pressure is removed 
from the uplines to the actuators which causes the three struts to “hang” in their respective uplock. 
This is also the preferred position of the LG lever during a manual extension attempt because of the 
depressurized hydraulic lines. 
 
When the gear (all or any) does not extend after a down selection, follow the QRH procedure in an 
attempt to lower the gear. Manual extension of the gear is accomplished by pulling the three “T” 
handles, accessible through the Manual Gear Extension Access Door just behind the FO seat on the 
cockpit floor. 
 
The need for this Non Normal procedure could be caused by: 
• Disrupted electrical signal to the LG selector valve 
• No system A hydraulic pressure available 
• LG lever stuck in the UP or OFF position 
 
When opening the Manual Gear Extension Access Door, a “door open” micro switch commands the 
LG selector valve electrically down regardless of the LG handle position. This action activates the LG 
selector bypass valve which connects the hydraulic lines to return so the manual down selection does 
not hydraulically restricts (locks) the actuators down capability. 
 
This also prevents the LG to retract when the door is not flush closed after take‐off and selected UP. 
This procedure is covered in the QRH by the LG disagree procedure with the LG handle UP and all red 
and green indicator lights illuminated, telling you the gear is down and locked but not in the selected 
position. 
 
When you’d pull any (or all) “T” handle it simply releases the uplock by cable action where after the 
respective gear free‐falls down, supported by gravity (weight) and airflow to the extend position. 
When the gear is fully down, the downlock “bungee” springs will hold the downlock struts in an over 
centered locked position. Normally this is accomplished by a downlock actuator but with the absence 
of system A pressure, the springs enforce a mechanical downlock which is indicated by (6) down and 
locked green lights. 
 
By the way, there are 6 green lights as a redundant indication. Neither gear is visible on the NG and 
the double green lights for each strut will give a backup for the down indication. 

   
18 
 
Mechanical pressure relief valves. 

There are three mechanical adjusted pressure relief valves on the 737. 
Positive safety pressure relief is accomplished by 2 mechanical adjusted pressure relief valves, 
located on each side of the outflow valve. They are totally independent of the pressurization system 
and prevent the inside/outside pressure to exceed +9.1 PSID in the event of a pressurization 
system/outflow valve malfunction. (stuck closed outflow valve) 
The fuselage airframe structure cannot withstand large negative pressures and is protected for that 
at a very low value. The negative pressure relief valve is located at the right lower side of the 
fuselage just fwd. of the outflow valve. This spring‐loaded door is also not depending on the 
pressurization system and adjusted at just a –1.0 PSID value. This will prevent the aircraft to collapse 
when the inside/outside pressure becomes negative for example during a (very) fast descent. 
 
 

19 
 
Nitrogen Generating System 

Following two Boeing 737CL explosion investigations in Asia (and others including the B747 TWA 800 
midair explosion), a protection was developed by Boeing to minimize explosive vapors in the center 
tank. The 737 explosions were caused by trapped fuel high temperatures due to radiant heat from 
the Packs under the tank which formed highly explosive vapors. The fuel was ignited by the center 
tank fuel pumps which were still running with an empty center tank. Early days center tank fuel 
pumps did not had an automatic shut off with LOW PRESSURE as the newer modified ones that shut 
down after ±15 seconds of LOW PRESSURE. This is also the reason that someone has to be on the 
flight deck when a center tank pump is running as by the FCOM, the book does not cover explicit 
modifications to each aircraft. 
 
This protective device (NGS) divides Nitrogen from Oxygen by a separation module and leaves 
Nitrogen enriched air (NEA) in the center tank to a level which will not support combustion. The 
oxygen level is decreased by the NGS to ±12% which is sufficient to prevent ignition. 
 
The NGS has only an indication available in the right main wheel well next to the APU fire control 
panel, so it has no visible clew for crews of its operation during flight. 
 
Indications are:  
• OPERATIONAL (green) 
• DEGRADED (blue) 
• INOPERATIVE (amber) 
 
The nitrogen generation system gets bleed air from the left side of the pneumatic manifold where 
after its cooled, driven through the separation module and directed to a flow valve into the center 
tank. The NGS operates automatically only in flight and shuts down in the next conditions: 
• Either engine is shut down in flight 
• Fire or smoke detection in any compartment 
• Left Pack overheat 
 

 
   

20 
 
Outflow valve. 

To stay in line with the previous post, let us look at this pressurization component of the 73. 
 
The outflow valve restricts/regulates the flow of conditioned air overboard, thereby creating a 
pressurized environment in the aircraft. The valve is located at the aft lower side of the fuselage and 
has raked edges for noise reduction purposes.  
 
The valve is moved by a common actuator which can be operated by either of the three outflow 
valve electro motors. Two motors are operated by the pressure system controllers and one is directly 
operated by a switch when in Manual operation.  
 
Automatic control is accomplished by means of 2 Cabin Pressure Controllers (CPC’s) which alter 
control each flight or when a malfunction occurs on the operating controller. A third way of 
controlling the outflow valve is by a manual toggle switch on the pressurization panel. The switch is 
spring loaded to neutral and has three positions, CLOSE – Neutral – OPEN. 
 
The outflow valve indicator shows the actual position of the outflow valve in all modes of operation 
provided the Battery Bus is powered through the PRESS CONT IND C/B.  
 
Electrical power to the three electro motors is provided by: 
 
• AUTO mode 1 electrical power to the auto electro motor 1 is supplied by the 28 VDC Bus 1 
through CPC 1. (PRESS CONT AUTO 1 C/B) 
• AUTO mode 2 electrical power to the auto electro motor 2 is supplied by the 28 VDC Bus 2 
through CPC 2. (PRESS CONT AUTO 2 C/B) 
• MANUAL mode electrical power to the manual electro motor is supplied directly by the 28 
VDC Battery Bus. (PRESS CONT MAN C/B) 
 
A mode selector is used to determine the operation of the outflow valve, either AUTO, ALT(ernate) 
or MAN(ual). 
 
The outflow valve receives a closed signal when the cabin altitude reaches 14.500 feet in the AUTO 
mode of operation so it is not affected through the MANUAL mode. 
 
Just for the “mind set” when at a high altitude and a pressure loss, you’d have to close the outflow 
valve to increase pressure in the aircraft which results in lowering cabin altitude. 
Aircraft control override devices. 
 

 
   
21 
 
Flight Control “Breakaway” Devices 

There are two devices that allow you to control the aircraft in case of a malfunctioning or jammed 
control system. 
 
One concerns roll control. When one of the yoke cables (or aileron PCU/spoilers) becomes jammed 
or moves freely, the opposite control is still available to roll the aircraft. The two yokes are 
interconnected at the base of the co‐pilots control column by the Aileron Transfer Mechanism 
through torsion spring friction and a “lost motion device”. If the FO control jams, the spring force can 
be overcome by the Captain thereby controlling the aileron PCU through cables. If the Captain 
control jams, the FO can control roll by use of the flight spoilers. Note that this only happens when 
the yoke has been turned ± 12° which engages a so called “lost motion device” which in turn 
operates the flight spoilers. 
 
The second is related to pitch control. When one of the control columns becomes jammed, the crew 
can override (breakout) the failing control. The control columns are interconnected below the 
cockpit floor by a torque tube with a device that enables the controls to be separated from each 
other. The Elevator Breakout Mechanism connects both control columns by two springs which will 
separate the columns when ± 30Lbf/13Kgf is used to overcome them. When applied, the control 
columns are mechanically separated from each other. Note that deflection of the elevators is 
significantly reduced and a higher force is needed to move the elevators. (even higher than with 
manual reversion)  
   

22 
 
Pack & pack control 

There are two Packs activated by an AUTO/HIGH selection that individually has two airflow 
directions, one that goes through a three stage cooling cycle (2 air to air heat exchangers and an 
expansion turbine) and one that bypasses the cooling machine and its components. The two flow 
directions are mixed at the output of the expansion turbine of the cooling machine. Air that enters 
the Packs through the Pack Flow Control and Shutoff valve is at ± 212°C and is conditioned and 
cooled to a mixed minimum Pack output of ± 18°C as set the lowest on the zone temperature control 
selectors. (auto zone temperature range is 18°C – 30°C)When these selectors are all in the OFF 
position, the left Pack puts out a fixed 24°C and the right Pack 18°C.  
 
There are two combined Zone/Pack controllers that control the required output temperature of each 
Pack. These two Pack Controllers have an auto “on side”, and a standby “off side” control, the latter 
takes over if an auto controller fails.  In this case a PACK OFF light illuminates on recall together with 
a Master Caution light. When both Pack Controllers fail, a Pack OFF light illuminates with a Master 
Caution light, the packs will still operate until a temperature exceedance occur. 
 
When a Pack becomes overloaded by the demand of cool air, a PACK trip off light illuminates with a 
Master Caution light and the Pack Flow Control and Shutoff valve closes shutting down that Pack. 
When the Pack cools down and the light extinguishes, the Pack can be reset by the reset button on 
the Bleed panel. To prevent this condition from re‐occurring select a higher temperature to “unload” 
that Pack by demanding less cold air from the cooling machine bypassing it. 
 
A Pack automatically provides a high airflow when the other Pack is selected to OFF provided the 
aircraft is in the air with flaps up. The other conditions require engine performance and inhibits the 
automatic high flow. 
 
Note: the image is just a simplified flow and pack component, and controller image to illustrate the 
flow through the pack and the components in both controllers. 
 

23 
 
Recirculation fans 

The recirculation fans are located under the cabin floor on the forward cargo compartment’s aft 
bulkhead. The purpose of these fans is to re‐use air drawn from the cabin and distribution 
compartment back into the mix manifold. Doing so there is no need for air from the Packs, thereby 
relieving the Packs from producing conditioned (cool) air improving engine performance. The left 
recirculation fan circulates air back into the mix manifold from the distribution compartment 
underneath the cabin floor (mix manifold/fan area), the right recirculation fan from the passenger 
compartment. 
When a higher amount of fresh air is needed from the packs, the recirculation fans are automatically 
shut down under several conditions with the recirculation fans selected to AUTO, and the isolation 
valve selected to AUTO or OPEN: 
 
On the ground using engine bleed air: 
Left RECIRC FAN shuts down when both Packs are selected to high flow 
 
On the ground using APU bleed air: 
Left RECIRC FAN shuts down regardless of Pack selection 
 
In flight using engine bleed air: 
Left RECIRC FAN shuts down when either Pack is selected to high flow 
Both RECIRC FANS shut down when both Packs are selected to high flow 
 
In flight using APU bleed air: 
Both RECIRC FANS shut down regardless of Pack selection 
 
Reading the first part it makes sense that the left fan (distribution compartment) shuts down first as 
this area heats up by the several operating components. (my personal point of view) 

24 
 
Hydraulic Reservoirs 

The 3 hydraulic fluid reservoirs are located in the front of the main wheel well. They are pressurized 
from the bleed manifold to supply positive fluid to the pumps, preventing cavitation and foaming.The 
standby system reservoir is pressurized through the B reservoir.These pressures (45 – 50 PSI) can 
only be checked on 2 gages mounted on the forward main wheel well bulkhead. Quantity of the A & 
B reservoirs is displayed directly through gages on the reservoir by a float type transmitter which also 
sends a signal to the DEU’s for display on the lower DU. The standby system reservoir only has a low 
quantity switch, which displays the STANDBY HYD LOW QUANTITY light on the flight control panel 
when < 50%. 
 
The A reservoir has a 20% standpipe to preserve fluid to the EMDP when a leak occurs at the EDP. 
The EDP is more likely to malfunction because of the engine gearbox mounted heavy design and 
higher capacity it puts out. (±4x) 
 
The B reservoir has a common standpipe for both system B pumps so when a leak occurs, fluid will 
drain the entire B reservoir until a 0% indication. In this case the B system cannot be pressurized 
anymore but the remaining 1.3 USG can be used for the PTU to operate the LE lift devices. A second 
standpipe at 72% preserves fluid to this level for both B system pump operation, in case a leak occurs 
while using the standby hydraulic system. 
Minimum quantity for the A & B reservoirs is 76% which triggers a white RF (refill) indication on the 
lower DU when on the ground and TE flaps are up, or no engines are operating. 
 
Besides that, when equipped with an update pin function to the lower DU on systems, there can also 
be a red dial indication when A or B quantities decrease to 0%, or increases to 106%. 
 
The pumps heated (case drain) cooling fluid return to the reservoirs, is routed through oil‐to‐fuel 
heat exchangers mounted on the bottom of the main tanks. To achieve enough cooling for on the 
ground operation, there should be at least 760 Kg of fuel in the tanks each. 
 
 

 
   

25 
 
The APU Starter/Generator. 

The APU is started through a starter/generator and when on speed transfers to an AC generator.  
The start sequence of the APU starter/generator is determined by the Generator Control Unit (GCU) 
which receives power from the Switched Hot Battery Bus. That is the reason why the Battery Switch 
must be in the ON position (switched hot battery bus energized) to operate the APU. When switched 
OFF, the Switched Hot Battery Bus and ECU become de‐energized which in turn shuts down the APU 
immediately without the regular 1 minute cooling cycle. (trips the generator off line and closes the 
APU bleed valve to unload/cool the APU prior shutdown) 
Strangely enough power to the starter is provided by either the Battery (28 VDC), or Transfer Bus 1 
(115 VAC). Both voltages are first changed/boosted to a whopping 270 VDC by the Start Power Unit 
(SPU), where after a Start Converter Unit (SCU) creates the 270 VAC which is needed to drive the 
starter/generator in the start mode. This signal lasts until 70% RPM where the SPU becomes de‐
energized and the APU becomes self‐sustaining and accelerates further to its operating RPM. 
When the APU RPM reaches ±95% the ECU commands the blue APU GEN OFF BUS light to illuminate 
as a signal that the APU generator can assume the electrical load.  
The AC generator consists of the same parts as the “regular” AC generator as described in an earlier 
post and can supply 90 KVA below 32,000 feet and 66 KVA at 41,000 because of APU load capabilities 
with low air densities. 
 
 

   

26 
 
Landing Gear Transfer Valve 

The Landing Gear Transfer Valve has two ways of operation. 
The simplest is to transfer the nose wheel steering operation from its normal hydraulic system A, to 
the alternate hydraulic system B on the ground (only), by a switch on the left front (Capt) panel. 
The second way of operation (in flight) is a bit more complex as it has 3 conditions that needs to be 
met before the LG transfer valve moves from its normal hydraulic system A operation for gear 
retraction to the alternate hydraulic system B. 
 
1. Engine #1, N2 below 50% 
2. Landing Gear Handle in UP 
3. Any gear NOT in the UP and locked position 

The PSEU is triggered by those conditions and moves the LG transfer valve to system B. Note that the 
PSEU light is inhibited from T/O thrust until 30 seconds after landing but DOES guard and operate the 
737’s systems. Losing engine #1 stops the EDP (hydraulic system A) output so the only way to 
pressurize the A system is by means of the Electric Hydraulic Pump which puts out 4 times less 
volume than the EDP. This would result in 4 times slower movement of its components including a 
gear retraction which is an unwanted situation just after takeoff or on a go‐around with N‐1 
conditions when you need to clean that configuration as fast as possible to decrease the massive 
drag by any extended gear. In that case the retraction is transferred from the A, to the B system so a 
normal fast retraction of the gear is achieved. 
The Power Transfer Unit (PTU) is a backup to the LE lift devices if the hydraulic system B EDP fails or 
has low output. It supports the B system electric hydraulic pump to operate the lift devices in a 
higher speed as it would be 4 times slower with just the EMDP. The PTU can also operate the lift 
devices when system B fluid is lost to a 0% indication, still holding ± 1.3 USG residual fluid in the 
reservoir to be used by the PTU.  

   

27 
 
PTU 

The PTU operates when the next conditions are met: 
1. Airborne and, 
2. System B EDP pressure low (< 2350 PSI) and, 
3. TE flaps less than 15° but not UP. 
 
If this occurs the PTU control valve opens, allowing system A pressure to operate the PTU hydraulic 
motor. The motor drives a hydraulic pump through a common shaft and uses the 1.3 USG from 
below the standpipe on the bottom of the B reservoir to operate the selected lift devices. Of course 
there are return lines back to the B reservoir from the PTU hydro motor and used devices which are 
not visible on common simplified (FCOM) schematics. 
 
Note that the PTU does NOT transfer fluid from A to B, and that the selected devices can be extended 
AND retracted by use of the PTU but will operate according the used pumps. (EMDP + PTU or PTU 
only) 
 

 
 
Teaser . . . .how CAN you transfer hydraulic fluid from A→B or B→A?? 
 
A →B 
1. EMDP's OFF.  
2. Release parking brakes, deplete accumulator (<1800 PSI) 
3. EMDP A, ON and apply parking brakes.  
4. EMDP A, OFF and depressurize by control column movement. 
5. EMDP B, ON and release parking brakes. (Sends the fluid back to system B)  
 
A →B 
1. EMDP's ON.  
2. EMDP B, OFF and depressurize by control column movement. 
3. EMDP A, ON and apply parking brakes. (Uses fluid from system A)  
4. EMDP B, ON and release parking brakes. (Sends the fluid back to system B) 
 
B →A  
1. EMDP's OFF 
2. Either FLT CONTROL to STBY RUD.  
3. No1 thrust reverser OUT (uses standby hyd sys)  
4. FLT CONTROL to ON.  
5. EMDP A, ON.  
6. Stow No 1 thrust reverser (using sys A)  
   

28 
 
Wing Thermal Anti Ice (WTAI) 

Wing anti‐ice is provided for the inner three LE slats only and is preferably used as a DE‐icer.  ANTI‐
ice would constantly heat up the LE thereby melting the ice crystals immediately, creating water 
“runback” over the wing and possibly freezing up on flight controls. Besides that it would have a 
negative effect on engine performance and fuel consumption.  
Note that use above FL 350 may cause a dual bleed trip off by the request of the amount of air also 
note that (ENG) anti‐ice is not required when < ‐40°C SAT. 
 
The outer slats are not de‐iced because the narrow outer slat cannot hold the hardware needed such 
as, a bleed manifold, telescopic tube and spray tubes. The wing is actually not producing much lift in 
that area anyway and they realized that some ice accretion on that part of the wing would not hurt 
too much. Eventually some drag and increase in stall speed occurs, not to forget that in case you use 
WTAI the stall warning computer remains set with increased speed logic. 
 
Where there is little cooling airflow over the LE on the ground, they are protected against 
overheating. First the engine bleed air is extra cooled through the pre‐cooler which allows tapped off 
fan air to extra cool the engine bleed air for maximum LE cooling on the ground. Second there is an 
overheat sensor (± 125 °C) which closes both WTAI valves when exceeded and opening up again at a 
predetermined value. 
 
During the design/test phase it turned out that ice does not accumulate on the empennage, mainly 
due to its position in relation to the engines causing hot air from the engines striking the empennage. 
Although some ice can build up in that area, it doesn’t have any adverse consequences (the stabilizer 
regularly changes the AOA and eventually shedding ice under the new conditions).  
 
The military version of the Boeing 737, the P8 Poseidon, does have a so‐called electro‐mechanical 
expulsion de‐icing systems (EMEDS) installed on the leading edges of the raked wingtips, horizontal 
and vertical stabilizers. The system is specially designed for the aggressive slow and low level cold 
weather mission assignments of this aircraft and does basically the same as a de‐icing boot but 
deforms the LE self by using low electrical current (28VDC and 25 Amps). 
 
 
 

   

29 
 
B737 Yaw damping 

Airplanes with continued Dutch Roll tendencies usually are equipped with gyro stabilized yaw 
dampers. The Boeing 737 has two yaw dampers, a primary– and a standby yaw damper that keeps 
the airplane stable around the vertical axis when selected ON and with the respective hydraulic 
system pressurized through minimum SMYD generated rudder inputs. 
 
When engaged in NORMAL OPERATION, the primary yaw damper provides input to the main Rudder 
Power Control Unit (PCU) solenoid valve and is controlled by the Stall Management and Yaw Damper 
Computer 1 (SMYD 1). The input solenoid valve uses hydraulic system B to move the yaw damper 
actuator which ads in the mechanical rudder input. The yaw damper itself does not feedback motion 
back to the rudder pedals. The yaw damper input to rudder movement is limited to 2° with flaps up, 
and 3° with flaps down.  
 
To engage the primary yaw damper select: 
• Hydraulic system B ON, 
• FLT CONTROL B switch ON and 
• YAW DAMPER switch ON 
o Engage light extinguishes 
 
When engaged during MANUAL REVERSION, the standby yaw damper uses the standby Rudder PCU 
and is controlled by SMYD 2 which operates with standby hydraulic system pressure.  
 
During manual reversion the so‐called “Wheel To Rudder Interconnect System (WTRIS) supports 
standby rudder operation through SMYD 2 which receives an input signal from the Captains control 
wheel for coordinated turns during manual reversion. 
 
To engage WTRIS and standby yaw damping select: 
• Both FLT CONTROL switches OFF 
• At least one FLT CONTROL switch to STBY RUD 
• YAW DAMPER switch ON 
o Engage light extinguishes 
 
Both FLT CONTROL A and B switches must be OFF to enable SMYD 2, and one or both switches must 
then be in the STBY RUD position to provide standby hydraulic pressure. WTRIS only operates at < M 
0.4 and yaw damper input to the standby rudder PCU movements are limited  to 2° with flaps up, and 
2.5° with flaps down. 
 
Both yaw damper systems are selected by a common “engage switch” on the Flight Control panel. 
When selected ON and the YAW DAMPER light extinguished, it only tells you the respective yaw 
damper is engaged regardless of operating by hydraulic pressure. During preflight the switch holds 
and the light extinguishes even without hydraulic system B pressure. The other way, if you’d lose 
system B pressure, the switch still holds with no light illuminated but primary yaw damping is lost. 
The switch only kicks OFF when the FLT CONTROL B switch is deselected from the ON position. To 
regain yaw damping you would have to transfer to manual reversion to operate the standby yaw 
damper with the standby hydraulic system which you (of course) will not do. 
   

30 
 
Zone temperature control 

Temperature control is achieved by mixing cool Pack air with hot Pack by‐pass air. The normal 
temperature range selection is from 18°C – 30°C through mixing cold air from the Packs with trim air 
for each individual compartment. The left Pack provides 20% to the Control Cabin and 80% to the mix 
manifold where the right Pack provides 100% to the mix manifold. The Zone/Pack controllers hold 
the various control electronics for the Cont Cabin and Passenger zones. The Cont Cabin has two 
controllers, a primary and a backup where the Passenger Cabin has only one controller for each area 
from either Zone/Pack controller. (see previous image) If both Cont Cabin controllers fail you’d get a 
Cont Cabin ZONE temp light with a Master Caution, if one fails they illuminate on recall. If a 
Passenger Cabin Controller fails the ZONE temperature light and Master Caution illuminates on recall 
and the two cabin requirement will be averaged. A ZONE temperature light also illuminate when 
there is an exceedance of duct temperature, the respective trim valve will close which can be reset 
by the reset button when cooled down. (select colder on that area) 
 
In the normal mode the Packs produce a temperature according the selection of the lowest 
temperature, the remaining zones use trim (hot) air required for their selected temperature. 
 
Unbalanced mode (Control Cabin trim air malfunction) 
The left Pack produces the selected Control Cabin temperature and the right Pack puts out the 
lowest Passenger Cabin selected temperature, the Passenger zone trim valves still operate. 
 
Unbalanced average mode (any Passenger Cabin trim air malfunction) 
The left Pack produces the selected temperature but the trim air valve still operates and the right 
Pack puts out an average of both Passenger Cabin selected temperatures. 
 
Single Pack operation and Trim ON results in normal temp control, with Trim switch OFF all trim 
valves close and the Pack averages the three compartment requirements. 
 
Trim switch OFF, all trim modulating valves are close and the left pack produces the selected Control 
Cabin temperature where the right pack produces an average of the Passenger Cabin selected 
temperatures. 
 
Temp selectors OFF will create a fixed 24°C output from the left and 18°C from the right Pack. 
 
 

   

31 
 
Lavatory “fire protection”. 

I noted also B737 cabin crew “Likes” to our FB page, so I’ll try to aim a couple of subjects in that 
direction, of course also “need to knows” for flight crews. 
 
Let’s start with Boeing’s approach of “fire protection”, of course we’re discussing fire detection & 
extinguishing NOT protection ;‐) 
 
The lavatory smoke detection system needs 28 VDC from DC Bus # 1 to operate. 
 
The lavatory is equipped with a smoke detection system and a fire extinguishing system. In some 73’s 
you still find a “SMOKE” annunciator light at the P5 forward overhead panel but mostly there is no 
indication on the flight deck.  
 
In the cabin we find smoke detection indications through the next components: 
 
1. Smoke Detector Unit 
As the name says, it’s a smoke detection and the unit is mounted against the ceiling of the lavatory. It 
has a green (power) light and a red (smoke detected) light, also an alarm horn will sound when 
smoke is evident for > 8 seconds. 
 
2. Lavatory Call Light 
Located above the lavatory and is a Call/Reset Light that flashes amber when smoke is detected. 
 
3. Master Lavatory Call Light 
At each EXIT locator light there are three indicator lights where a flashing amber Master Call Light 
indicates there is smoke detected in the lavatory in that respective area (fwd. or aft).   
 
4. Attendant Control Panels (fwd.& aft) 
On these panels there are more options than just smoke detection as you can test the system here 
and detect FAULTS. When smoke is detected a red light flashes together with a flashing locater light 
that identifies the area where the smoke is detected and an intermittent horn is sound through the 
panel. The switches and lights on the panel are self‐explanatory, when a FAULT is detected during a 
test the failing detector is indicated through the location indicator. 
 
5. Passenger Address (PA) system 
The PA sounds a repetitive high chime when smoke is detected. 
 

32 
 
Center tank boost pumps 

There are two boost pumps located in the center tank that feed fuel into the engine supply fuel 
manifold at a rate of ± 10.000 Kgs per hour. The valves are mounted on either side of the crossfeed 
valve so with a closed crossfeed valve the pumps provide pressurized fuel to their respective side, 
the left center boost pump is than needed to supply positive fuel feed to the APU. Electrical power to 
operate the pumps are left, AC transfer Bus 1 and right, AC Transfer Bus 2. 
 
The design is such that there is no backflow possible through the pumps, meaning a check valve 
prevents fuel transfer through the engine feed manifold. These pumps also do not have a by‐pass 
valve which is needed for suction feed as with the main tank fuel pumps so, fuel in the center tank is 
trapped when both center tank pumps are OFF or producing no pressure. (the fuel scavenge jet 
pump (100 – 200 Kgs/hr.) is not considered a transfer flow) 
 
The center tank boost pumps are of a higher pressure then the main tank pumps thereby causing the 
center tank to empty first to prevent wing root stress when this would not be the case. The FCOM 
limit states that the wing tanks have to be full when there is more than 453 Kgs of fuel in the center 
tank. The second limit is related to that, i.e. when there is more than 453 Kgs in the center tank the 
boost pumps must be ON. 
 
I posted the C‐130 video where wing root stress caused the wings to shear off, the wing tanks were 
not full and the aircraft uploaded water and chemicals in a huge tank inside the aircraft every time to 
fight forest fires. About the same happens when the 453 limit is not honored with a possible 
exceedance of the MZFW. 
 
There are updated center tank boost pumps that automatically switch OFF when LOW PRESSURE 
(<22 PSI) is detected for >15 seconds. As these newer type pumps modifications are not covered by 
the FCOM the NOTE still exists to be on the flight deck when a center tank pump is operating. 
 
The 2 LOW PRESS lights on the fuel panel are extinguished when the pumps are OFF where the main 
tank pumps show LOW PRESS with their switch OFF. I call that “Recall Logic” as this would be a 
normal condition when the center tank is empty and the pumps OFF, preventing the MCS to 
illuminate FUEL at the Captain side Annunciator Panel (Recall) when pushed with the center tank 
empty and the switches selected OFF. The LOW PRESS circuit is checked when the pumps are 
selected ON for a short moment until the 22 PSI is reached. 
   

33 
 
Antiskid 

The 73 is equipped with a system that prevent wheels from skidding (decelerating), thereby 
optimizing braking capabilities on any runway surface condition. 
 
An antiskid condition releases brake pressure to the affected wheel(s) which stops the skid condition 
when: 
• Uncommand deceleration. (Antiskid protection) 
• Wheel(s) stops instantaneously. (Locked wheel protection) 
• Landing with (parking) brakes ON. (Touchdown protection) 
• Hydroplaning 
 
To detect a wheel uncommanded deceleration, an electrical so‐called transducer is mounted 
underneath the hubcap of each wheel and is monitored by the Antiskid/Autobrake Control Unit 
(AACU). This signal is compared to information from both Air Data Inertial Reference Unit’s (ADIRU’s) 
and is also used for auto brake system wheel speed functions. 
 
The AACU controls the anti‐skid system and monitors for malfunctions which are indicated on the 
flight deck by an Antiskid Inoperative Light. An additional signal to the AACU comes from the parking 
brake system because the normal antiskid system returns (releases) hydraulic fluid through the 
parking brake valve. When the parking brake valve has a disagree with the lever (switch) the antiskid 
inoperative light also illuminates. 
 
Antiskid is provided during operating normal (system B), alternate (system A), and operation of the 
brakes with residual accumulator pressure. When in normal operation, antiskid is provided through 4 
antiskid valves for each wheel separately and during alternate or emergency (accumulator) operation 
through 2 antiskid valves whereby the wheels are protected in pairs. 
 
To allow retract brakes to operate (Alternate brake pressure, system A) the antiskid system is de‐
energized when the gear retracts. 
 
Be aware that the antiskid system releases brake pressure, also during emergency (accumulator) 
operation which would reduce emergency brake applications when stepping on the brakes too hard. 

34 
 
Leading Edge Flaps 

High‐lift devices on each wing are 2 LE Krueger Type Flap Panels and 4 LE Slats. The LE flaps have 1 
extend position, Full Extend where the LE Slats have 2 positions, Extend and Full Extend, indicated on 
the aft overhead panel. On the center instrument panel just below the (TE) Flaps Indicator there is 
also an amber LE FLAPS TRANSIT, and a green LE FLAP EXTEND light. 
 
In NORMAL operation, the LE Flaps move by system B pressure to extend when the TE Flaps travel 
away from the UP position. They move in sequence after the TE Flaps travel to their selected position 
as commanded mechanically by a follow‐up cable system of the TE Flaps system. The extend time 
from UP to EXTEND takes ± 7 seconds and from EXTEND to UP ± 7.5 seconds. When the B system 
pressure is low, a so‐called priority valve gives operation priority to the LE Flaps over the TE Flaps. It 
reduces the flow rate to the TE Flaps, so the LE Flaps move relatively faster to their extend position. 
 
When the B system EDP pressure is low, the PTU supports LE Flap extend & retract movement. Refer 
for PTU operation elsewhere on this B737Theory FB page. 
 
In ALTERNATE operation, the LE Flaps uses standby hydraulic pressure and can only extend the LE 
Flaps. (Red guarded switch indicates an irreversible action) In this case the command is electrically 
through the Alternate Flap switches on the Flight Control Panel and the extend time from UP to 
EXTEND is ± 32 seconds. 
 
During cruise, pressure is removed from the LE Flap hydraulic system which creates a hydraulic lock 
of the LE Flaps. This prevents LE Flap extension at high speeds/altitudes which is accomplished by 
command of the Flaps and Slats Electronic Unit (FSEU).  
This condition exists when the next condition is met for >5 seconds: 
• Air born, 
• Flap Lever UP, 
• LE Flaps (and Slats) UP 
 
The LE uncommanded motion (UCM) detection function stops the LE normal operation if two or 
more LE flaps (or slats) move away from their commanded position. 
 
Different than the LE Slats, the LE Flaps do not have an internal actuator locking device so when 
residual system B pressure has leaked away during extended parking, the panels can droop off by 
their weight and gravity forces. This will de‐activate the Stall Warning Test capability. 
Rudder (vertical stabilizer) load reduction 
As on most large aircraft the vertical stabilizer is one of the most fragile structural parts. It cannot 
withstand large loads caused by full rudder deflection at higher speeds and therefore is protected 
against those high forces. The 737 rudder main PCU receives input from the pedals through input 
levers and a feel and centering unit which moves the rudder panel by hydraulic system A & B 
pressure. Pressures will be at normal values (± 3000 PSI) when flying < 137 Kts, above 137 Kts a load 
limiter reduces system A pressure to 1450 PSI resulting in a ± 25% reduction of the total load on the 
rudder. The result of this reduction protects the vertical stabilizer against high forces at a higher 
speed, leaving full pressure and deflection available when needed, at takeoffs and landings for 
directional control. 
 
An example of the vertical stabilizer “weak point” is an attempt in 2001 to recover an A300 after 
being struck by wake turbulence and aggressive maximum rudder inputs which sheared of the 
vertical stabilizer. Also note that the vertical stabilizer was the only intact part of the Air France 447 
incident over the Atlantic. 

35 
 
 
In the past of “my field of experience” I saw a vertical stabilizer of a P3 Orion totally being sheared 
off like it was removed with a chain saw when it struck a wash rack when the aircraft has been 
swapped around by a twister at NAS Jacksonville and when a P3 hits a power cable at Pago Pago 
Hawaii. 
 
Be aware of the structural design of your aircraft!! 
 

 
   

36 
 
Thrust Reverser 

Each engine is equipped with a thrust reverser system that reduces stopping distance and brake disc 
wear. The T/R’s reverse the fan airflow forward through blocker doors, cascades and translating 
sleeves 
 
The left T/R uses hydraulic system A and the right, system B where they both are able to receive 
standby hydraulic pressure when their respective hydraulic system is unserviceable. Note that T/R 
use with standby pressure is of a lesser rate so, losing one main hydraulic system will operate that 
side slower than with main system pressure creating a possible swerve during reverser action. 
 
The T/R’s are controlled by the T/R levers on the thrust levers and operate when < 10 ft. RA or on the 
ground. The T/R operates when the thrust lever is at the Idle position and the T/R handle is lifted to 
the interlock position when the isolation valve positions to deploy the “translating sleeves”. The 
EEC’s determine through a Linear variable differential transformer (LVDT) a 60% opening of the two 
sleeves on each T/R, where after the mechanical interlock releases and the levers can be lifted 
further to the Detent 1, 2 or MAX position. 
 
When the sleeves move, the CDS shows the next message on the Upper DU. 
• Amber REV when deploying or stowing 
• Green REV when fully deployed 
 
When stowing the T/R’s, the stow command is initiated by passing the 1 Detent position which 
commands the T/R sleeves to stow. When the T/R lever is full down and the sleeves at the 0% 
(closed) position, the isolation valve closes and the locks engage. 
 
During normal operation the amber REVERSER light on the engine control panel illuminates for 10 
seconds without a MASTER CAUTION during a T/R stow operation and extinguishes when the locks 
are engaged. The light will stay illuminated if the T/R does not stow in 10 seconds, indicating a 
malfunction. 
 
When the light illuminates for more than 12 seconds a malfunction is detected and the ENG 
annunciator and MASTER CAUTION light illuminates. 
 
When the down motion of the T/R levers is delayed for more than 18 seconds, the ENG annunciator 
and MASTER CAUTION light illuminate and the locks will engage, preventing further movement of the 
sleeves. To clear this situation you can cycle the levers to the interlock position and back down. 
 
When a serious malfunction or disagree exists between the LVDT’s, the ENGINE CONTROL light 
illuminates on the engine control panel together with a MASTER CAUTION. When illuminated, it 
could mean a serious engine (EEC) malfunction or an LVDT malfunction/disagree, when illuminated 
do not dispatch the aircraft. 
 

37 
 
Each T/R translating sleeve has two deactivation points, installing two pins at these points prevents
T/R deployment. Follow the “thrust reverser deactivation for flight dispatch procedure” from the current
(AMM) manual to operate the aircraft with deactivated T/R’s. 
 
An auto–restow circuit compares actual reverser sleeve position to the commanded position. When 
it determines an incomplete stowage or uncommand movement of the sleeves to the deployed 
position, the circuit commands to stow the T/R. When activated, the isolation valve remains open 
and the control valve is held in the stowed position until the thrust reverser is commanded to deploy. 
 
 

 
   

38 
 
Tail Skid 

To protect the aft lower fuselage from over rotation damage the 737NG is equipped with a Tail Skid. 
It consists of a sort‐of shock absorber cartridge, a skid fairing and a skid “shoe”, where the last two 
parts are outside the fuselage where all other parts are inside. 
 
A light touch to the runway causes the shoe to wear off, indicated by 4 dimples on the shoe 
indicating the amount of wear and is an indication when the shoe needs to be replaced. 
 
When the shoe hits an object or an uneven part of the runway during the skid, the lower part of the 
shoe shears off as on the left image to indicate a tail drag but does not damage the skid fairing. 
 
A firm touch crushes the cartridge pushing the skid fairing inside the aft fuselage. The higher the 
force the further the skid disappears indicated by colored decals. If the green decal is still visible the 
skid is still “serviceable” but if the green decal disappears inside the fuselage, the red decal indicates 
that the skid must be replaced. 
 
When the “kiss to the runway” is more than firm, the skid disappears totally inside the aft fuselage 
and a safety pin (fuse pin) allows the cartridge to pivot inside (other than crushing) thereby 
protecting the aircraft structure against massive loads. 
 
There is also an option for a retractable tail skid that extends on take offs and landings which is under 
control of the Supplemental Proximity Sensing Electronic Unit (SPSEU) and operates with hydraulic 
system A pressure.  
 
The SPSEU commands the tail skid to extend if: 
• In the air for 2 minutes and, 
• Landing gear lever is DN and, 
• Either engine is running  
 
The SPSEU commands the tail skid to retract if: 
• On the ground 5 seconds or, 
• Landing gear lever is not DN or, 
• No engines operating 
 

 
   

39 
 
Vortex generators. 

The 737 is equipped with several boundary layer control devices or, vortex generators (VG’s). 
They are mounted on the next locations: 
• the wings 
• the tail cone 
• the inner engine nacelle 
• the nose 
• the APU inlet door 
 
The vortex created by the VG affects the boundary layer on the respective surface behind the device 
by “pulling” air from outside, into the boundary layer. It creates an air swirl that draws air from 
above the boundary layer into this layer intensifying it and making it more compact. VG’s are 
mounted to slow, control or even prevent boundary layer separation. 
 
VG’s are used on the 737 wings to improve high Mach pitch characteristics beyond initial buffet and 
to lower stall speeds in the landing configuration. The (back swept) wing design creates a relative 
weak boundary layer where the outboard wings are more sensitive to initial flow separation. The 
purpose of the wing VG’s is to strengthen the boundary layer (especially with high AOA’s) and direct 
the airflow on the surface controls. 
 
On the tail cone, VG’s are mounted to separate the flow field from the horizontal tail thereby 
reducing drag, improving performance and reducing elevator vibrations. 
 
A Vortex Control Device (or nacelle chine) is installed on the inboard side of the nacelles. The engines 
are mounted relatively close to the wing which results in air disturbance at high angles of attack. To 
control the air flow at high AOA’s and slow speed, a Boeing invented VCD is mounted on the inner 
side of the engine nacelle. The created nacelle vortex is delayed with high AOA’s to support the 
airflow over the wing, increasing lift in those conditions. 
 
There are a number of VG’s mounted on the nose of the aircraft just before the windows. The 
general purpose is to reduce airflow noise by ± 3 – 4 Dbs. on the flight deck, directing the airflow 
away from sharp edges and corners of the windows. 
 
On the APU inlet door, there is a VG installed to improve high altitude starting of the APU. When the 
inlet door is opened during flight, the VG improves inlet ram recovery and thereby the pressure 
difference across the APU even to assist (electrical) starting. 
 
 

40 
 
Window heating 

Window heat is provided to improve impact resistance (bird hit), ice buildup and defogging and 
should be selected ON at least 10 minutes before take‐off. Each frontal window (L & R SIDE & FWD) 
have an own Window Heat Control Unit (WHCU) which receive power from their respective 115 VAC 
Transfer Bus. 
 
This heating is accomplished by laminated glass and vinyl window layers with in‐between a 
conductive layer that allows electrical current to flow through it when heating is selected. This 
“gradual increasing” current flow creates heat by resistance in the layer towards a target 
temperature of ±43°C. The WHCU adjusts heating current in its operating range to prevent a thermal 
shock and reduces the current flow at higher ranges to prevent an over temperature. Window heat 
becomes active when selected to ON and the window temperature is < 37°C, indicated by a green ON 
light (or extinguished OFF light) meaning there is current flow through the conductive layer. When 
the window reaches the target temperature the WHCU interrupts electrical power and extinguishes 
the ON light (or illuminates the OFF light) which could already be the case when parked into the sun 
on a hot day.  
 
To make sure the system operates when needed, there is a POWER TEST switch that by‐passes the 
thermistor and sends electrical current through the windows. Be aware this action will bypass the 
control unit temperature regulation so when activated too long it could cause an overtemp condition 
in that window. 
 
 Another test function is the OVHT TEST switch that simulates an overheat condition with the window 
heat switches in ON, indicated by amber OVHT lights on the control panel and extinguished ON lights 
(or illuminated OFF lights). The simulated overheat must be reset by selecting the window heat 
switches to OFF than back to ON. 
 
When a window “overtemps” at values higher than 62°C, the WHCU interrupts power to the affected 
windshield and illuminates an OVERHEAT indication together with an extinguished ON light (or 
Illuminated OFF light). This condition can be reset by selecting the affected window to OFF and back 
to ON when allowed sufficient cooling first (2 – 5 minutes according the QRH).  
 
When window heat is inoperative prevent speeds above 250 Kts at altitudes below 10.000 ft. to 
minimize the effect when a bird strike occurs on the window. 
 
 

 
   

41 
 
Wing& Body Overheat 

On the P5 overhead bleed panel, there are 3 caution lights mounted that warns you for an overheat 
condition in the bleed system. Two of them are INSIDE the manifold and considered “safe” as they 
have a reset function after the overheat condition is corrected, the BLEED TRIP OFF and PACK light.  
The third light is the WING‐BODY OVERHEAT light that indicates an over temperature OUTSIDE the 
manifold and is considered “not safe”. This indication determines an overheat in the area where the 
duct is located indicating a duct leak or worse, a duct rupture. 
 
The areas covered by the left indication are: 
• Left engine strut (154°C) 
• Left inner leading edge (154°C) 
• Left air condition compartment (124°C) 
• Keel beam area (124°C) 
• APU bleed duct area (124°C) 
 
The right indication covers the engine strut, leading edge and air condition on the right side. 
 
When a wing & body overheat condition (leak) exists, use the current QRH to determine the location 
and isolate the leak by selecting a combination of pneumatic system related switches to OFF. When 
located and isolated, the temperature drops and extinguishes the indication knowing that the 
overheat has disappeared but not the cause of the indication. 
 
When the correct QRH procedure was followed the overhead condition should clear as the source 
has been removed somewhere during the procedure. If not . . . the QRH doesn’t suggests steps 
beyond the procedure so use common sense to fly out of this condition. 
 
The system has a test switch located on the P5 bleed panel to test the continuity of the sensing 
loops. The test starts when the button is pushed > 5 seconds and indicates the same as in an 
overheat condition by the next amber indications: 
• WING‐BODY OVERHEAT 
• AIR COND annunciator 
• MASTER CAUTION 
 
 

 
   
42 
 
Horizontal Stabilizer Trim. 

One of the important features related to pitch and load balancing is the movable horizontal stabilizer 
trim control (stab trim). A control jackscrew moves the leading edge of the horizontal stabilizer as a 
trim in order to achieve this goal and can be operated: 
• Manually by two trim wheels which operate the stabilizers gearbox and jackscrew through 
cables and cable drums. 
• Electrically either through yoke trim switches or Auto Pilot command to the stabilizer 
electrical trim actuator. 
o AC power – AC Transfer Bus 2 
o DC control – DC Bus 2 
 
Electrical movement of the trim actuator by either the yoke switch‐ or the Auto Pilot will backdrive 
the trim wheels on the control stand. When the handle on the wheels are extended during electrical 
operation, this can injure the operators leg/knee. 
 
Extreme UP of the leading edge is restricted at 4.2°, and DOWN at 12.9°. Indication in “Units” is 
mechanically provided on the control stand through a flexible cable that is driven off the trim control 
mechanism underneath the flight deck floor. As reference, the 0° neutral position equals 4 units on 
the trim position scale. 
 
Stabilizer Trim Cutout switches are located on the control stand in order to interrupt either control 
column switch–, or AP electrical power toward the trim motor when an uncommanded movement or 
“runaway” trim occurs. 
 
A Stabilizer Trim Override switch is located on the aft electronic panel in case a counter movement of 
the trim is required opposite of the control column movement. When not in OVERRIDE, a mechanical 
control column actuated stabilizer trim cutout switch will interrupt electric power to the trim motor 
when attempting to trim opposite of control column or AP commanded force. (column nose DOWN 
vs. trim UP or vv) 
 
The override switch can also be used to by‐pass the control column actuated stabilizer trim cutout 
switches in the event both (yoke switch or AP) fail in the open position, to be able to operate the 
stab trim. 
 
Electrical movement by the yoke switches can vary between high speed (0.4 unit/sec) when the flaps 
are NOT UP and low speed (0.2 unit/sec) when the flaps are fully UP. When the trim is under AP 
control high speed is 0.27 unit/sec while low speed with the flaps UP is 0.09 unit/sec. 
 
 

43 
 
Display Electronic Units. 

There are two DEU’s in the Common Display System (CDS) which are located in the E & E bay that 
receive data from the B737’s aircraft systems and avionics. This data is converted into a video signal 
that is send to the six Display Units (DU’s) on the flight deck. Both DEU’s provide data toward all six 
DU’s but are differently powered. DEU 1 is powered through the 28 VDC Standby Bus and DEU 2 
through the 28 VDC Bus 2. They both have a “hold‐up power” from the Hot Battery Bus which is used 
to supply power to the DEU’s during power surges of maximum 2 seconds or else the DEU powers 
down. Both DEU’s “crosstalk” to compare critical data and when there is a difference, this could 
create an amber CDS FAULT indication as described below. 
 
The same “split” is made for powering the components that distinguish DU operation when powering 
up the aircraft. I mean when the Battery Switch is selected ON, DEU 1 is powered through the DC 
Standby Bus but also both Captains–, and Upper DU’s, as well as the Captains EFIS control panel. 
Note that it takes ± 90 seconds to get display because the DEU has to become operational. When the 
DC Bus 2 becomes powered the same applies for the First Officers side. 
 
An (undispatchable) amber CDS FAULT displays on both PFD’s when there is a DEU operational failure 
on the ground and one engine operating. When both engines are operating or when in the air the 
CDS FAULT message is replaced by a DISPLAY SOURCE message. The DISPLAY SOURCE also shows 
when one DEU is selected (ALL ON 1 or 2) to provide all six DU’s with data. 
 
Note: Switching too fast between SOURCE selections can create a possible incorrect data display, use 
a 1 – 2 second interval when switching between the SOURCES. 
 
A (dispatchable) white CDS MAINT indication tells us that there is a partial data input malfunction on 
a DEU when on the ground and one engines is not operating. 
 
 

44 
 
Proximity Switch Electronic Unit 

The PSEU is located on the right side in the E & E bay and receives input from the six strut 
compression sensors (2 on each strut). These ground/air signals are used by the PSEU for several 
aircraft systems and/or indications such as: 
 
• Landing gear transfer valve 
• Landing gear position indicating and warning 
• Speedbrake deployed indication 
• Takeoff warning 
• Door warning 
• Air/ground relays 
• See image . . .  
 
The PSEU also serves as a FAULT detection regarding several aircraft systems when on the ground 
and the thrust levers <53°, or after landing when on the ground for >30 seconds and the thrust levers 
<53°.  
 
Generally speaking, the PSEU light is inhibited in flight but it does monitor systems and records any 
FAULT to be annunciated 30 seconds after landing.  
 
When a system status FAULT is detected or an overwing exit flight lock fails before take‐off, the PSEU 
light illuminates together with the OVERHEAD annunciator and a MASTER CAUTION light. 
 
An undispatchable FAULT is evident when the PSEU light illuminates after landing when on the 
ground >30 seconds and the thrust levers <53°, in this case the light can only be reset by a BITE check 
of the PSEU or when the FAULT is corrected by maintenance. 
 
A dispatchable FAULT exists when the PSEU light illuminates after landing when on the ground for 
longer than 30 seconds and the thrust levers <53° and the light extinguishes when the parking brake 
is set or the engines are shutdown. A dispatch fault will not cause a recall of the Master Caution 
annunciator light but just illuminates the PSEU indication. 
 
A dispatchable (simple) FAULT occurs if the PSEU light illuminates when pressing RECALL and resets 
by pressing MASTER CAUTION. 
 
The SPSEU light or Supplemental Proximity Sensor Electronic Unit is provided that uses the Landing 
Gear DOWN signal to extend the two position tail skid and/or to determine a failure of the flight 
locks on the additional 2 mid exits. (– 900’s) 
 
Note that some indications are only valid for certain models/serials. 

45 
 
Nose wheel steering lockout 

Yesterday I answered a question to one of our followers and want to share this (obvious) info. 
 
When towing or pushing the aircraft with a tug and tow bar, system A pressure has to be removed 
from the nose wheel steering system.  It prevents unwanted dangerous movements of the tow bar 
injuring people or damaging the nose wheel steering system. 
It is done either by switching both A pumps to OFF or by use of the towing lever and lockout pin to 
depressurize the nose wheel steering system.  
Moving the lever to the towing (fwd.) position moves the towing shutoff valve to such a position that 
it shuts off A hydraulic pressure to the steering valve and connects both sides of the steering valve to 
each other, and return. This allows the nose gear to rotate freely to a maximum of 78° indicated by 
red stripes on the lower side of the fuselage. Moving the nose wheel beyond the stripes requires 
disconnecting the torsion links or even the taxi light wiring. 
 
Most companies wants you to always switch the A pumps OFF even if the lockout pin is installed as a 
safety measure. This is done to prevent miscommunication with the multi‐cultural ground observers 
related to pin installation. 
 
Just thinking about the system as an engineer . . . . . remember the NOSE WHEEL STEERING switch. 
When it is selected in Alternate on the ground, it moves the Landing Gear Transfer valve to select B 
system pressure to nose wheel steering!!! 
 

 
   

46 
 
Weather radar 

The on‐board weather radar can provide the following information: 
• Weather 
• Windshear 
• Terrain 
 
The WXR switch on either EFIS panel activates the weather radar and displays the weather radar data 
on the ND in the MAP, MAP CTR, VOR & APP modes. (not in the plan mode) The radar covers 180° in 
front of the aircraft by receiving transmitted radio frequency echo pulses on the ND’s. When selected 
on the EFIS control panel in a correct display mode, the DEU’s send an analog discrete to the weather 
radar control panel which sends it to the weather radar transceiver and switches it ON. 
 
When the aircraft is equipped with a predictive wind shear system (PWS), it’ll be available below 
2300ft. The weather radar does not need to be switched ON for the PWS to work, it switches ON 
automatically when take‐off thrust (PL > 53°) is set. PWS information is available after the WXR 
switch on either EFIS control panel is pushed and a 12 sec warm up period, where after Alerts 
become available. 
 
Alert activation regions for TAKE‐OFF are: 
• Warnings and Cautions are enabled from 0 knots until the aircraft reaches 80 knots.  
• From 80 knots until the aircraft passes 400 feet, only Warnings are enabled.  
• From 400 feet through 1,200 feet, Warnings and Cautions are enabled.  
• All alerts are disabled from the time the aircraft passes 100 knots until it reaches 50 feet. 
 
Alert activation regions for APPROACH are: 
• PWS switches automatically ON when the airplane descends below 2300 feet RA. 
• PWS switches automatically OFF when one of the next conditions occur: 
o Aircraft speed is less than 60 knots. 
o Aircraft climbs above 2300 feet RA. 
 
If PWS is ON and WXR is not selected on the EFIS panel, all antenna sweeps search for wind shear. If 
WXR is selected, the antenna uses one sweep to search for wind shear and the other sweep to search 
for normal weather returns. PWS operation does not affect the WXR mode or range selected by the 
flight crew. 
 
Alert activation regions for LANDINGare: 
• Warnings and Cautions are enabled from the time the aircraft passes 1,200 feet until 400 
feet. 
• From 400 feet until 50 feet, only Warnings are enabled. 
• From 50 feet until touchdown (0 feet), all alerts are disabled. 
• No display Wind shear alerts are active in the cockpit below 1,200 feet AGL. 
 
   

47 
 
The weather radar actually enters the wind shear scanning mode at 2,300 feet AGL to provide time 
for the system to power up (if necessary) and update the displays before the aircraft reaches the 
1,200 feet AGL level. 
 
TEST 
During the test: 
• The R/T transmits a few pulses to let the BITE monitor for correct operation 
• The R/T makes a test pattern and sends it to the DEU to show on the ND’s 
• The R/T sends test messages, mode, gain and tilt information to the DEUs to show on the 
ND’s 
• WXR test pattern shows on ND’s. 
• The test pattern shows until another mode on the WXR panel or EFIS panel is selected. 
 
 

 
   

48 
 
Dissolved air 

A fuel phenomena within high altitude aviation is called “dissolved air” or “aeration”. 
 
It is a result from the highly aerated condition of fuel caused by rapidly decreasing tank pressure 
during climb, allowing entrapped air in the fuel to expand. Reduced air pressure above the fuel 
surface promotes the release of dissolved air from the fuel. Air released from the fuel can have 
degrading effects on the performance and safe operation of a fuel system.  
 
2 Main tank fuel pump LOW PRESSURE’s during rapid climbout can cause thrust deterioration or 
even an engine flameout on the affected engine at higher altitudes (> ± 13,000 feet).  
(QRH, FUEL PUMP LOW PRESSURE) 
This altitude varies with the prevailing fuel temperature in the tank (the higher the fuel temperature, 
the lower the altitude at which the gradual power loss occurs).  
 
Once pressure has stabilized and excess air has escaped from the fuel, loss of both fuel boost pumps 
has no effect on engine operation with maximum power settings at altitudes up to above 30,000 
feet. The time required to stabilize the fuel from this highly aerated condition cannot be determined 
exactly, since it is a function of both rate‐of‐climb and fuel temperature.  
 
Solution to the problem is level off and let the engines stabilize at altitude or pressure feed the 
engines as suction feed increases the aeration effect and ads in the possibility to ingest aerated fuel 
into the engine feed line. 
 
Fuel stabilization should occur after a few minutes of stabilized cruising operation or back on 
pressure feed. 
 
 

   

49 
 
Frangible fittings 

Frangible fittings are mounted in the rim of the main wheel wells to prevent a rotating blown tire to 
enter the wheel well. If it shears, only that side will freefall back down by relieving Landing Gear 
Actuator up pressure overboard. (4 green and two red indications) 
Note that we do have retract brakes through the alternate brake system (hydraulic system A) but 
when a tire blows there is a good chance that the brake lines will be substantially damaged causing 
the retract brakes not to work. 
 
Retract brakes (and nose wheel snubbers) are mounted to stop the wheels from rotating, hanging in 
their uplocks. A high speed rotating wheel would cause tremendous precession forces to the 
structure during a turn that’s why they are stopped after retraction. 
 

 
   

50 
 
Rudder(vertical stabilizer) load reduction 

As on most large aircraft the vertical stabilizer is one of the most fragile structural parts. It cannot 
withstand large loads caused by full rudder deflection at higher speeds and therefore is protected 
against those high forces. The 737 rudder main PCU receives input from the pedals through input 
levers and a feel and centering unit which moves the rudder panel by hydraulic system A & B 
pressure. Pressures will be at normal values (± 3000 PSI) when flying < 137 Kts, above 137 Kts a load 
limiter reduces system A pressure to 1450 PSI resulting in a ± 25% reduction of the total load on the 
rudder. The result of this reduction protects the vertical stabilizer against high forces at a higher 
speed, leaving full pressure and deflection available when needed, at takeoffs and landings for 
directional control. 
 
An example of the vertical stabilizer “weak point” is an attempt in 2001 to recover an A300 after 
being struck by wake turbulence and aggressive maximum rudder inputs which sheared of the 
vertical stabilizer. Also note that the vertical stabilizer was the only intact part of the Air France 447 
incident over the Atlantic. 
 
In the past of “my field of experience” I saw a vertical stabilizer of a P3 Orion totally being sheared 
off like it was removed with a chain saw when it struck a wash rack when the aircraft has been 
swapped around by a twister at NAS Jacksonville and when a P3 hits a power cable at Pago Pago 
Hawaii. 
 
Be aware of the structural design of your aircraft!! 
 

51 
 

You might also like