You are on page 1of 1

Gas Turbine Generator Package

TITAN 130
Turbine type: TITAN 130 (T 20501)
Main data (ISO, no losses)

Electrical power: MW 15.00


Heat rate: kJ/kWE-hr 10’200
Fuel input: MJ/s 42.6
Efficiency: % 35.2
Exhaust gas flow: kg/s 49.8
Exhaust gas temp. °C 496
Fuel: NG/LF/LPG/LBTU
Start system: DC
Gen. Voltage: kV 11
Comb. Syst. Avail.: * S/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
17.500 11.300 55,00 530
17.000 11.200 54,00 <--- EGF 525
<--- kWe
16.500 11.100 53,00 EGT ---> 520
16.000 11.000 52,00 515
Gen. Output Power (kWe)

HR --->

Exh. Gas Temperature (°C)


15.500 10.900
Heat Rate (kJ/kWh)

51,00 510
Exh. Gas Flow (kg/s)

15.000 10.800
50,00 505
14.500 10.700
49,00 500
14.000 10.600
48,00 495
13.500 10.500
13.000 10.400 47,00 490

12.500 10.300 46,00 485

12.000 10.200 45,00 480


11.500 10.100 44,00 475
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

www.turbomach.com