You are on page 1of 3
Mahindra Defence Systems Limited Mahindra a ees Village : Praha, Dist. :Palwel - 121 102 DEFENCE Henjana (ld 080 281 smstrnahindra.cam ‘Websste : wiv, mahindra.com To Date: 17” July 2018 Sterlite Technologies Limited 3rd Floor, IFFCO Tower | Plot No. 3, Sector 29 Gurgaon 122001 Haryana, India Subject: OEM’s Certificate Reference: Tender for Procurement of Naval Airfield Integrated Security System (NAISS) for six Naval Air Stations (RFP No. IHQ MoD (N)/DNAS/AO/9110/AP SEC/EQPT DATED 09 OCT 2017) Dear Si This is with reference to the above mentioned Tender; we, M/s Mahindra Defence Systems Limited hereby comply the following parameters. S. | RFP Clause No. | Parameter/Specification ‘Compliance | Remarks No. (Yes/No) T | Part V Appendix | The MSCP should be a high floor bus/ | Yes “B” truck type heavy duty vehicle (Indian Clause No. 101 | chassis) of about 26 feet and will (a) house all the facilities of the central | command post. 2 | Part V Appendix | The MSCP should be bullet proof | Yes “B” | against fire from AK 47/ 56 from Clause No. 101 | close range. ©) 3 | Part V Appendix | It should have an independent Yes “B" generator to meet power requirements Clause No, 101 | of all associated equipment onboard, © | Registered Office : Mahindra Towers, P.K.Kume Chowk Dalh Ofice “Mahinda Toners, Dr. GM Bhosale Mrge, Wor, Mumbai -400018 2A, Bhikap Cama Pace, New Oelhi-110 088 “Maharashtra india Deh inca (GN: U75220MH2012PLC233889 Te) 91-11.41220900, Fax: 91-11-41458505 Mahindra DEFENCE 4 | Part V Appendix | It should have a concealed bullet- | Yes “B" proof weapon post to provide security | Clause No. 101 | and fire cover atop the vehicle, () 3 | Part V Appendix | Tt should have two PTZ cameras on | Yes Electronic “B” | either end of the vehicle with 360 interface and Clause No. 101 | degree rotation capability to provide storage to be | @ all round coverage. taken up by | Sterlite. [6 | Part V Appendix | The MSCP should be air conditioned | Yes | “BY and should have a separate cooling | Clause No. 101 | arrangement for the equipment. |__|) 7 | Part V Appendix | The command post should have a Yes “B” seating arrangement to accommodate Clause No. 101 | 10-12 personnel. o 8 | Part V Appendix | The vehicle should have Bullet proof | Yes “B” tinted windows in order to deny Clause No. outsiders from looking inside the 101(m) vehicle and allow personnel seated inside to have a clear external view. Part V Appendix | The vehicle should be externally Yes “BP painted matt black. Clause No. 101(n) | [10 | Part V Appendix | The vehicle should have the following | Yes iB external lights:- Clause No. 101 | Emergency lights o) Trainable flood lights TT | Part V Appendix | The mobile standby command post | Yes “B” should have but not be limited to, the Clause No. 102. | following technical specifications: (a) ‘Type of vehicle -- High floor heavy duty rear wheel bus/ Truck or better Mahindra DEFENCE 12] Part V Appendix | Bullet Proof plates -- All around the | Yes vehicle minimum NIJ level IV Clause No. 102 oO (©. Bullet Proof plates — All around the vehicle minimum. Vehicle has protection against fire from AK 47/56 (Indian Ammunition) as per Part V Appendix “B” Clause No. 101 © | 13 | PartV Appendix | Bullet proof post atop the vehicle-- | Yes “B” 4m X 3m X3m | Clause No, 102 (h) (h) Having bullet proof post atop of the vehicle of 4m X 3m X 3m then total vehicle will be too high and practically not feasible, MDSL vehicle will be overall size of dm X 3m X3m, Authorized Signatory Mukesh Kumar Gupta Head-Design

You might also like