9 STOREROOM
13.9.1 STORAGE AREAS
All storage areas should be fireproof structures and have concrete floors. They should be located above
ground level, and have adequate ventilation. The area should be protected from direct sunlight since
temperature control is essential. Where lubricants, chemicals and gas bottles are required to be stored,
separate areas should be provided for each. View windows into the storage rooms with light and
ventilation switches located on the outside should be considered in layouts.
13.10 CHLORINE
Leak detection devices should be installed in areas where chlorine is used or stored. Such equipment will
signal the leakage of gas. Storage for gas masks should be provided outside each area where chlorine is
used or stored.
13.11.2 PUMPS
Both suction and delivery pipework should be valved to prevent sludge or gas from entering the work area
when the pumps are removed or dismantled.